Klimaenergy mercato pv dell’esistente in evoluzione - 26.03.2015
PV - Metro 4€¦ · PREFABBRICATO IMPERMEABILE Sp. 20cm FACCIA A VISTA E/O RIVESTITI DOVE PREVISTO...
Transcript of PV - Metro 4€¦ · PREFABBRICATO IMPERMEABILE Sp. 20cm FACCIA A VISTA E/O RIVESTITI DOVE PREVISTO...
RV.3CN.3PV.3A 06
DIAFRAMMI STRUTTURALI
STRUTTURE PORTANTI IN C.A.
FOROMETRIE/CAVEDI A SOFFITTO
FOROMETRIE/CAVEDI A PAVIMENTO
LEGENDA
TIPOLOGIA PAVIMENTO TIPOLOGIA RIVESTIMENTO
TIPOLOGIA CONTROSOFFITTO
SUPERFICIE PAVIMENTOCODICE LOCALE
LOCALI COMMERCIALI
ZONE APERTE AL PUBBLICO
RV.3CN.3PV.3A 06
LEGENDA
000.00 P.R.- QUOTA PAVIMENTO RUSTICO000.00 P.F.- QUOTA PAVIMENTO FINITO
PAVIMENTO TECNICO SOPRAELEVATO
PAVIMENTO IN GRES SU CASSEFORME A PERDERE TIPO IGLU'
2) PER COMPARTIMENTAZIONI REI SI VEDA PROGETTO SPECIFICO
3) PER DETTAGLI IMPERMEABILIZZAZIONI SI VEDA PROGETTO SPECIFICO
4) PER STRATIGRAFIE RELATIVE AD ORIZZONTAMENTI E PARETI SI VEDANO ELABORATI SPECIFICI
MURATURE IN BLOCCHI CAVI DI CLSPREFABBRICATO IMPERMEABILE Sp. 20cmFACCIA A VISTA E/O RIVESTITI DOVE PREVISTODAL PROGETTO CON RESISTENZA AL FUOCO REI 120
PILETTE Ø150 PER RACCOLTA ACQUE METEORICHE:PREVEDERE GUAINA BITUMINOSA 4mm E OPPORTUNICOLLEGAMENTI AL POZZO DI AGGOTTAMENTO
1) PER FINITURE MATERICHE E CROMATICHE, ARREDI FISSI, IMPIANTI A SERVIZIO DELL'UTENZA E CORPIILLUMINANTI SI VEDANO RELATIVI ABACI ED ELABORATI DI DETTAGLIO
5) PER SERRAMENTI E CONTROSOFFITTI SI VEDANO ELABORATI SPECIFICI
6) PER DETTAGLI INERENTI LA STRUTTURA DI COPERTURA DI SCALE FISSE E MOBILI, ASCENSORI ETORRINI IMPIANTISTICI SI VEDANO ELABORATI SPECIFICI
NOTE
CLS INDUSTRIALE SU CASSEFORME A PERDERE TIPO IGLU'
7) LA POSIZIONE E LE DIMENSIONI DEI SOTTOSERVIZI ESISTENTI E DI PROGETTO RAPPRESENTATI SONOINDICATIVI. PER I SOTTOSERVIZI SI VEDA PROGETTO SPECIFICO.
PAVIMENTO IN GRES ROSSO
Rev. Data CO CO Autore Verificatore Approvatore Descrizione della Revisione
TRACCIABILITA' DELLE REVISIONI
Validatore/ AutorizzatoreRAMSRev.Int. DataSOCIETA' Prot.
Commessa
- - - - - - - - - - - - -
PIANTA PIANO CONDIZIONAMENTO (QUOTA +111.99)SCALA 1:100
PIANTA PIANO ATRIO (QUOTA +107.44)SCALA 1:100
A
1
B
C
D
E
F
G
H
A
B
C
D
E
F
G
2 3 4 5 6 7 8
1 2 3 4 5 6 7
NOTE GENERALI
P R O G E T T O E S E C U T I V O
CONSORZIO MM4(Ing. Guido Mannella)
MM METROPOLITANA MILANESE S.p.A. - IL DIRETTORE DEI LAVORI(Ing. Francesco Venza)
COMUNE DI MILANO - RESP. UNICO DEL PROCEDIMENTO(Ing. Francesco Tarricone)
SCALA:
REV DATA DESCRIZIONE REDATTO VERIFICATO APPROVATO
Nome del file: Codice interno:
PROG. FASE TRA AR. TIPO OP. PAR. DISC. SPEC.E.ORIG. 3 T. DOC. PROGR. REVCAT. OP. SUB
Categoria
SOGGETTO ESECUTORE
RESP. INTEGRAZIONI DISCIPLINE SPECIALISTICHE(Ing. Gregorio Braida)
IL PROGETTISTA
M4E1CFST13000MB02ACPI00003A00.dwg
Tipo opera - operaParte d'opera
Titolo elaborato
E. ORIG. 2
AMAT - ALTA VIGILANZA(Ing. Camilla De Micheli)
FORMATO: PAG.:
Rev. interna:
Disciplina specialistica
M4 S.p.A.(Ing. Giorgio Desideri)
(Ing. Massimo Lodico - METRO BLU S.c.r.l.)
(Ing. Lamberto Cremonesi - Crew s.r.l.)
Variante CentroStazioni - Stazione Sforza Policlinico-ArchitetturaPianta piano condizionamento e pianta piano atrio
A 15.07.16 Prima emissione G.Lonati C.Turrini A.Carrettucci
1:100 A0 1 di 1
M 4 E 1 C F S T 1 3 0 0 0 M B 0 2 A C P I 0 0 0 0 3 A- 00
2.30
1.50
2.20
2.65
Canalettaraccolta acque
112.54
1.20
1.20
0.50 2.80
0.30 0.30
1.00
0.30
3.85
0.30
107.44
0.30
0.30 7.20 0.30 3.60 0.30
109.14 P.R.
RV.4CN.-PV.-
SOTTOSCALA
25 23
canaletta metallica
40 55
31
ALAGGIOVENTILAZIONE
ALAGGIOVENTILAZIONE
canaletta diraccolta acque
PLENUM EFFETTO PISTONE
corrimano metallico
corr
iman
o m
etal
lico
VANO ASCENSORI
scala alla marinara
114.19
1
1415
30
CANALE UTA
0.90
2.10 0.90
2.10
m²4I2
LOCALECONTATORI
0.90
2.10
m²81I1LOCALE CENTRALE IDRICAm²120I3
LOCALECONDIZIONAMENTO
exp cdz aerazione cdz
Canalettaraccolta acque
UTA 1
UTA 2
Condizionamentodi banchina 100x40 cm
VI GF
QC
DZ
6.50
1.20
30.05 0.50
0.50
7.90
0.50
0.60
0.30
5.10
0.30
0.30 3.20
3.50
2.65 0.30 31.96 0.50
m²25I4DISTRIBUTIVO
111.89 P.R.111.99 P.F.
0.30
1.85
0.30
4.100.40
1.20 1.20 1.20
8.407.
90 8.10 111.89 P.R.
111.99 P.F.
111.89 P.R.111.99 P.F.
Canalettaraccolta acque
RV.4CN.4PV.7
RV.4CN.4PV.7
RV.4CN.4PV.7
RV.4CN.4PV.7
111.
28
0.30
canaletta metallica
corrimano metallico
107.24 P.R.107.44 P.F.
115.82
0.30
1.801.80
1.80
2.10
2.10
1.80
6.60
2.30
0.60
0.60
22.3
0
117.68
m²32A3RV.4CN.4PV.-
m²190A4RV.4CN.4PV.4
0.80
25.06
16.132.80
m²790A13RV.1CN.1PV.1
0.80
2.40
2.40
10.03
6.80
19.5
0
107.24 P.R.107.44 P.F.
105.36
0.800.60 0.50 0.80 0.80 1.20
107.81
m²30A6
D.A.B. D.A.B.
28.08
2.30
1.50
2.30
1.50
4.50
2.65
1.20
0.50
8.55
0.40
2.25
0.50
1.20
14.6
0
8.06
2.30
1.50
2.20
2.65
0.90
2.10
0.902.10
D.A.B.D.A.B.
0.90
2.10
m²12A1RV.4CN.4PV.4
10.40 0.30
2.40
3.50
0.90
2.10
m²5A7
105.36
106.64 P.R.107.44 P.F.
107.24 P.R.107.44 P.F.
107.24 P.R.107.44 P.F.
0.800.60 37.99
2.80
4.50
4.20
1.50
m²39A11
m²11A7RV.4CN.4PV.4
m²90A5RV.4CN.4PV.5
m²4A2RV.4CN.4PV.6
106.64 P.R.107.44 P.F.
106.64 P.R.107.44 P.F.
106.64
m²10A10
19.99
RV.4CN.-PV.5
RV.4CN.-PV.5
RV.4CN.-PV.-
1.20
1.20
parapettotutto vetro
8788
99
96 scalinia = 16 cmp = 30.00 cm
parapetto tuttovetro
LOCALE ARRIVO A2A
Pavimento in gres susottofondo in igloo
SOTTOSTAZIONEELETTRICA
113
1 16 31 43 64
64 scalinia = 16 cmp = 30.00 cm
ATRIOALAGGIO /VENTILAZIONE
VENTILAZIONE
asola impianti civili
Condizionamentodi banchina 100x40 cm
BIGLIETTAZIONE
Canaletta continua (l=12cm p=10cm) per raccolta acquemeteoriche,prevedere guaina bituminosa 4mm eopportuni collegamenti al pozzo di aggottamento
ALAGGIO /VENTILAZIONE
LOCALEA2A/ASTS
1
13 26
ContatoriA2A
porta a tenuta
PLENUMVENTILAZIONE
LOCALE QUADRISCALE MOBILI
passo d'uomo
DISTRIBUTIVO
62 scalinia=16.0 cmp=30.0 cm
EFFETTO PISTONE
DISTRIBUTIVO
PLENUMVENTILAZIONE
WC PUBBLICI
M.A.T.M.A.T.
Canalettaraccolta acque
Canalettaraccolta acque
Canalettaraccolta acque
VANO ASCENSORE
VANO ASCENSORI
VANO ASCENSORI
Scala allamarinara
corrimanometallico
corrimano metallico
corrimanometallico
parapettotutto vetro
scala allamarinara
griglia
parapettometallico
parapetto metallico
parapetto metallico
1.15
2.10
LOCALEMACCHINE PULIZIA
0.90
2.10
porta a tenuta
SOTTOSCALA
0.90
2.10
0.902.10
0.902.10
0.902.10
1.152.10
Quadri ascensore
1.15
2.10
m²7A8
DISTRIBUTIVO
2.10
2.10
12.00
1.80
1.90
m²15A9
RV.4CN.4PV.7
m²-A12RV.4CN.4PV.2
4.00
65.15
ALAGGIO /VENTILAZIONE
107.44
2.20
1.50
2.70
2.20
1 (D. H.)
2
3
4
5
6
7
8
9
103.60
55
116.
08
109.
84
112.
24
114.
16
105.
20
canaletta continua l=12cm p=6cm per raccoltaacque meteoriche - prevedere guaina bituminosa4mm e opportuni collegamenti al pozzo diaggottamento
RV.4CN.4PV.7 RV.4CN.4PV.7 RV.4CN.4PV.7
RV.4CN.4PV.7
RV.2CN.3PV.1
107.24 P.R.107.44 P.F.
Puntone rivestitoin acciaio inox
7787100
22
1.20
55 scalinia=18.0 cmp=30.0 cm
pannello diseparazione in lamiera
canaletta continua l=12cm p=6cm per raccoltaacque meteoriche - prevedere guaina bituminosa4mm e opportuni collegamenti al pozzo diaggottamento
parapetto metallico
RV.4CN.4PV.6
106.79 P.R.107.44 P.F.
107.24 P.R.107.44 P.F.
107.24 P.R.107.44 P.F.
107.24 P.R.107.44 P.F.
107.24 P.R.107.44 P.F.
6
91.34
12.0
0
14.96 3.75 3.70 6.10
2.10
109.
36
102.84
103.54
parapettotutto vetro
asola risalitaimpianti