Page 1: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C.D.C. MOTOR CONTROLS

PLN

Page 2: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

 

Page 3: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S1

PLN

0913A

Pag.Page

Indice Index

PLN19-8

Schema dei collegamenti Main connection diagram S2Caratteristiche tecniche Technical features S2Dimensioni Dimensions S3Opzioni Options S3

PLN20PLN40

Schema dei collegamenti Main connection diagram S4Caratteristiche tecniche Technical features S5Dotazioni Equipment S5Manuale User manual S5Dimensioni Dimensions S6GUIDA alla selezione dell’azionamento Drive selection GUIDE S7

Note Note S8

Questa sezione annulla e sostituisce ogni precedente edizione o revi-sione. Qualora questa sezione non Vi sia giunta in distribuzione con-trollata, l’aggiornamento dei dati ivi contenuto non è assicurato. In tal caso la versione più aggiornata è disponibile sul nostro sito inter-net www.transtecno.com

This section replaces any previous edition and revision. If you obtained this catalogue other than through controlled distribution channels, the most up to date content is not guaranteed. In this case the latest ver-sion is available on our web site www.transtecno.com

Page 4: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S2

AZIONAMENTO UNIDIREZIONALE PWM PER LA REGOLAZIONE DI VELOCITA’ DEI MOTORI A CORRENTE CONTINUA A BASSA TENSIONE

LOW VOLTAGE SINGLE DIRECTIONPWM DC MOTORS CONTROL

SCHEMA DEI COLLEGAMENTI - MAIN CONNECTION DIAGRAM

Attenzione: se si scollega il potenziometro con la scheda alimen-tata, il motore ruota alla velocità nominale.

Warning: if speed pot is disconnected when the board is powe-red, the motor runs at its maximum speed.

Caratteristiche tecniche Technical features

● Alimentazione ai terminali FA1 e FA2: 12 - 24 Vca oppure 15 - 35 Vcc.

● Regolazione della velocità mediante potenziometro 10-15 KΩ.

● Trimmer di Limitazione della corrente, per adattare la scheda anche a motori di piccole potenze. Per limitare l’ erogazione di corrente, ruotare in senso orario il trimmer.

● Uscita motore ai terminali FA3 e FA4, regolabile da 0 a Vcc MAX che è proporzionale alla tensione di ingresso. Con 35 Vcc di alimentazione, l’uscita MAX è circa 30 Vcc.

● Corrente di uscita (*): Massima corrente ammessa: 8 A in am-biente ventilato, servizio continuo.

● Peso: 0.120 Kg.

● Line voltage at terminals FA1 and FA2: 12 – 24 Vac or 15 – 35 Vdc.

● The speed of the drive is to be controlled by potentiometer, 10-15 KΩ.

● Current Limit trimmer, in order to suit the board for small mo-tors. In order to limit the current, turn clock wise the trimmer.

● Output voltage from terminals FA3 and FA4, from 0 up to Vdc MAX which is proportional to the input voltage. With 35 Vdc input voltage, the max output voltage is about 30 Vdc.

● Output current (*): Maximum output current allowed: 8 A in a ventilated environment, continuous duty.

● Weight: 0.120 Kg.

PLN19-8

Page 5: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S3

PLN

Dimensioni Dimensions

Opzioni Options

72 mm

40 mm62 mm=

=

=

87.5

mm

77.5

mm

=

4 x 4.0 ø

FA

1

FA

4

FA

2

FA

5

FA

3

FA

6

FA

7

10 mm

MIN

ITE

CN

O

PLN

19-8

L.C

.

1. Potenziometro 10 kΩ2. Supporto per montaggio su guida DIN

1. Speed potentiometer 10 kΩ2. DIN mounting support

(*) il valore massimo di corrente motore deve essere utilizzato in ambien-te ventilato. In ambienti non ventilati e per temperatura ambiente di 45 °C, ridurre la corrente motore massima a 4 A; servizio continuo.

(*) the maximum output current value must be used in a ventilated en-vironment. Derate the maximum output current down to 4 A if the envi-ronment is not ventilated and the temperature is about 45 °C; continuous duty.

PLN19-8

Page 6: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S4

AZIONAMENTO BIDIREZIONALE PWM PER LAREGOLAZIONE DI VELOCITA’ DEI MOTORI A CORRENTE CONTINUA A BASSA TENSIONE

LOW VOLTAGE BIDIRECTIONALPWM DC MOTORS CONTROL

SCHEMA DEI COLLEGAMENTI - MAIN CONNECTION DIAGRAM

PLN20-PLN40

1

2

3

4

5

6

7

8

Marcia indietro / Run reverse

Marcia avanti / Run Forward

FusibileFuse

Pw-

Pw+

M+

M-

B+

B- LD1 LD2 LD3

1 1

8 8

2 23 34 4

5 56 67 7

Connettore comandi

Inputs connector MOLEX minifit 8 vie

MOLEX minifit 8 pins

Pot. 5 -10 kΩkΩSegnale anal. est. / Ext. anal. signal

NC

+ V

Reset

GND

-V Freno motore-V Motor brake

-V Negativo alimentazione-V Negative supply voltage

+V Positivo alimentazione+V Positive supply voltage

-V Cavo motore-V Motor

+V Freno motore+V Motor brake

+V Cavo motore+V Motor

Riferimento di velocità / Speed setpoint:

- Segnale analogico esterno 0 ÷ +10V sui pin 1 (GND) e pin 2 (segnale) oppure potenziometro. External analog signal 0 ÷ +10Vdc pin 1 (GND) and pin 2 (signal) or speed pot.

Comando marcia/arresto / Run/stop command:

- Pin 3 marcia avanti e pin 8 marcia indietro. Attivo sul fronte di salita (avanti → Pin M+ = +V). Pin 3 run forward and pin 8 run reverse. On the rise side of the command (forward → Pin M+ = +Vdc)

Fusibile: Fuse:150-200% della corrente motore. Max 3 volte la corrente nomi-nale della scheda, con intervento entro pochi secondi.

150-200 % rated motor current. Max 3 times rated current of the drive (trip time in few seconds).

Trimmer multigiro: Multiturn trimmers: TR1: Accelerazione: selezione da 0.5 a 10 sec. TR1: Acceleration time: from 0.5 to 10 sec.TR2: Limite di corrente: riduce il limite di corrente nominale da 100% a circa 30% (corrente di picco 3 volte la corrente selezionata).

TR2: Current limitation: rated current limited from 100% to about 30% (peak current 3 times the selected limited current).

TR3: Decelerazione: selezione da 0.5 a 10 sec. TR3: Deceleration time: from 0.5 to 10 sec.

LED: LED: LD1: Visualizza lo stato di funzionamento con limite di cor-rente attivo (il motore assorbe più della corrente selezionata e l’azionamento opera in limitazione).

LD1: ON when the drive runs under current limitation (motor requires more than the rated current and drive supplies only limited current).

LD2: Stato dell’azionamento: lampeggio veloce e continuo = funzionamento normale, lampeggio lento e codificato = pre-senza di un allarme

LD2: Status: quick continuous flash = drive ok, slow coded flash = fault).

LD3: Segnalazione presenza alimentazione. LD3: Power ON

Page 7: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S5

PLN

Caratteristiche tecniche Technical features

● Scheda bidirezionale a transistor a ricircolo di corrente. ● Selezionabili i seguenti parametri (mediante trimmer):

- rampa di accelerazione: 0.5 - 10 sec - rampa di decelerazione: 0.5 - 10 sec - limite corrente 100%-30% circa

● Temperatura di lavoro: 0°C / +40°C (allarme sotto zero) ● Diagnostica tramite LED ● Frequenza di commutazione: 16kHz ● Dotata di coperchio ● Velocità regolabile con potenziometro 5-10 kΩ o con segnale

0-10 Vcc ● Limitazione della corrente regolabile ● Sensore termico di protezione

● Transistor bidirectional drive with regenerative current system. ● Following settings can be adjusted (by built in trimmers):

- acceleration ramp: 0.5 - 10 sec - deceleration ramp: 0.5 - 10 sec

- current limit 100% - about 30%

● Room temperature: 0°C / +40°C (alarm below zero) ● LED for system diagnosis ● Switching frequency: 16kHz ● Covered ● 5-10 kΩ Speed pot. or 0-10 Vdc external signal for speed re-

gulation ● Variable current limit ● Thermal sensor for protection

PLN20-PLN40

ModelloModel number

Tensione di alimentazione

DC input voltage[Vdc]

Tensione di uscitaMotor voltage

[Vdc]*

Corrente di uscita nominale

DC load current[A]

Corrente di picco motoreMaximum load current

[A]**

Campo di alimentazione

Power supply range[Vdc]

PLN20 12 ÷ 24 0 ÷ Vin 20 60 (4 sec) 10 ÷ 30PLN40 12 ÷24 0 ÷ Vin 40 120 (4 sec) 10 ÷ 30

Dotazioni Equipment

PLN20PLN40

Trimmer di selezione ACCEL, DECEL e LIMITE di CORRENTE / Selection Trimmer ACCEL, DECEL, CURRENT LIMIT ■2 contatti: marcia avanti e marcia indietro / 2 contacts : forward and reverse ■Riferimento di velocità / Speed setpoint reference ■3 LEDs di segnalazione / 3 LEDs signals ■Segnale di comando di eventuale freno negativo di stazionamento / Command signal for possible negative electromagnetic brake ■Predisposizione per montaggio a libro e a zoccolo / Arranged for 2 different ways of mounting ■Memorizzazione e segnalazione degli allarmi / Memory storage and report of allarm ■2 ingressi digitali ausiliari / 2 auxiliary digital inputs ■#

# uno impegnato dal reset / one comitted by reset

* L’azionamento riduce la tensione nominale di 1-2 Vcc. Il fenomeno è normale e fisiologico. Se serve ottenere 24 ÷ 12 Vcc in uscita sotto ogni condizione di carico, si suggerisce di sovralimentare di un paio di volt.** Un timer impone il limite con un andamento temporale iperbolico, cioè quanta più corrente eroga e tanto meno è il tempo per il quale ciò è am-messo, prima che appunto la scheda vada in limitazione. Alla corrente di picco (x 3 volte quella nominale) la scheda funziona per pochi secondi.

* The drive reduces the rated voltage of 1-2 Vdc. This is normal and physiological. If 24 ÷12 VDC output is required under all load conditions, it is advisable to supercharge a couple of volts.** A timer imposes a limit with a temporary hyperbolic performance, which means the more current is requested, the less time is permitted with this current before the drive is limited. When the current reaches its peak (3 times the rated value) the drive will work for a few seconds.

Manuale User manual

Per approfondimenti si raccomanda di scaricare il manuale d’uso dal nostro sito www.transtecno.com alla pagina dei prodotti.

Please, download the user manual for more information from our web site www.transtecno.com from the product page.

! !

Page 8: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S6

AZIONAMENTO BIDIREZIONALE PWM PER LAREGOLAZIONE DI VELOCITA’ DEI MOTORI A CORRENTE CONTINUA A BASSA TENSIONE

LOW VOLTAGE BIDIRECTIONALPWM DC MOTORS CONTROL

Dimensioni Dimensions

PLN20-PLN40

==

146

83 30.9

3 3ø 6.5ø 6.5

34

17

152

140

140

117

146

104 20.4

30.983

3 3

177

164

140

140

117

164

==

34

17

ø 6

.5ø

6.5

ø 6

.5ø

6.5

PLN20

PLN40

Page 9: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

S7

PLN

GUIDA alla selezione dell’azionamento Drive selection GUIDE

Corrente di usodel motore ≤ Corrente nominale

dell’azionamento

Attenzione: la reale corrente assorbita dal motore può essere di-versa da quella indicata in targhetta.PLN19-8 = max 6 APLN20 = max 22 APLN40 = max 44 AVedere sotto la tabella per esemplificazioni

Real motorcurrent ≤ Rated current

of the drive

Warning: the real absorbed current by the motor can be different from the one written on the nameplate.PLN19-8 = max 6 APLN20 = max 22 APLN40 = max 44 ASee the table below for quick reference

Codice motoreMotor code

Corrente motoreMotor current

S1

Scheda-Drive(servizio motore-motor duty)

S1

Corrente motoreMotor current

S2

Scheda-Drive (servizio motore-motor duty)

S2

EC020.120 3.2 PLN19-8 – PLN20 4 PLN19-8 – PLN20

EC020.240 1.5 PLN19-8 – PLN20 2 PLN19-8 - PLN20

EC035.120 5.2 PLN19-8 – PLN20 8 PLN20

EC035.240 2.6 PLN19-8 - PLN20 4 PLN19-8 - PLN20

EC050.120 6.8 PLN20 9.4 PLN20

EC050.240 3.4 PLN19-8 - PLN20 4.7 PLN19-8 - PLN20

EC070.120 8.4 PLN20 11.8 PLN20

EC070.240 4.2 PLN19-8 - PLN20 5.9 PLN19-8 - PLN20

EC100.120 12 PLN20 16.8 PLN20

EC100.240 6 PLN19-8 - PLN20 8.4 PLN20

EC100.24E 6 PLN19-8 - PLN20 8.4 PLN20

ND100.120 13.9 PLN20 19 PLN20

ND100.240 6.9 PLN20 9.0 PLN20

EC180.120 21.5 PLN20 30 PLN40

EC180.240 10.8 PLN20 15 PLN20

EC180.24E 10.8 PLN20 15 PLN20

ND180.120 20 PLN20 30 PLN40

ND180.240 10 PLN20 14 PLN20

EC250.120 30 PLN40 39 PLN40

EC250.240 15 PLN20 19.5 PLN20

EC350.120 42 PLN40 58.8 ----

EC350.120BR

EC350.240 21 PLN20 29.4 PLN40

EC350.240BR

EC600.240 35.5 PLN40 47 PLN40

EC600.240BR

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

Page 10: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S8

Note Notes Note

Page 11: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S9

PLN

Notes Note Notes

Page 12: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS

S10

Note

Page 13: AZIONAMENTI PER MOTORI C.C. D.C. MOTOR CONTROLS fileD.C. MOTOR CONTROLS S3 PLN Dimensioni Dimensions Opzioni Options 72 mm 40 mm =62 mm = 87.5 mm 77.5 = 4x4.0 ø A 1 A 4 A 2 A 3 5

DC

20

14

DC

DC G

EARM

OTOR

S

SaleS Office Brazilrua Dr. freire alemão 155 / 402ceP. 90450-060auxiliadora Porto alegre-rS-BrazilTel. +55.51.3251.5447fax +55.51.3251.5447Mobile +55 51 811 45 [email protected]

SaleS Office OceaNiaUnit 11, 5-27 Wallace ave Point cook 3030 Victoria - aUSTraliaTel. +61.03.9369.9774fax +61.03.9369.9775Mobile +61.0438.060.997oceaniaoffice@transtecno.comwww.transtecno.com.au

SaleS Office fraNce 12 impasse des Mûriers 38300 ruy - fraNceTel.  +33 (0) 6 85 12 09 87fax – italy  +39 051 [email protected] www.transtecno.fr

SaleS Office eaSTerNeUrOPe & MiDDle eaSTSt. Magnolienweg 4D-31860 emmerthal - GerMaNYTel. +49.5151.963076fax +49.5151.963076Mobile [email protected]

SaleS Office SOUTH KOrea D-304 Songdo Brc Smart Valley 30, Songdomirae-ro, Yeonsu-gu, incheon, 406-840, KOreaTel: +82 (0) 70 8288 2107 fax. +82-32-815-2107Mobile: +82 10 5094 2107 [email protected]

SaleS Office GUaNGzHOUroom 401a, leTian Building,No.188 Tangan road, Tianhe District, Guangzhou city, 510665 - cHiNaTel:+ 86 20 38776057 fax: + 86 20 [email protected]

SaleS Office iNDiaa/10, anagha,S.N road, Mulund (W),Mumbai, 400080iNDiafax – italy  +39 051 733904Mobile: +91 [email protected]

SaleS officeS

w w w . t r a n s t e c n o . c o m

TraNSTecNO SrlVia caduti di Sabbiuno, 11 D/e40011 anzola emilia (BO) - iTalYTel. +39.051.6425811fax [email protected]

HaNGzHOU TraNSTecNOPOWer TraNSMiSSiONS cO; lTDchanglian road, fengdu industry zone, Pingyao town Yuhang area, Hangzhou, 311115 - cHiNaTel. +86.571.86920260fax. [email protected]

GearTecNO iTalia SrlVia ferrari, 27/1141043 fraz. corlo, formigine (MO) - iTalYTel. +39.059.557522fax [email protected]

TraNSTecNO B.V.De Stuwdam 43ind. terrein Wieken/Vinkenhoef3815 KM amersfoortTHe NeTHerlaNDSTel. +31.(0)33.4519505fax +31.(0)[email protected]

HeaDQUaRTeRS manUfacTURing PlanT

SaleS officeS & waReHoUSeS

caTM

OTOr

iDDc

1013

TTN

Procedi srldesigned by