Ago Bussola

1
7/30/2019 Ago Bussola http://slidepdf.com/reader/full/ago-bussola 1/1 Physik Chemie Biologie Technik  LEYBOLD DIDACTIC GMBH 8/95 Gebrauchsanweisung 513 11/51 Instruction Sheet The magnetic needle (513 11) on base (513 51) is particularly suitable for introductory experiments on magnetism, and for ex- periments with current-carrying conductors, coils and electro- magnets. The base for the magnetic needle (513 51) can also be used as a support for the magnet with cap and pole marks (510 16) as well as for the glass tube with bearing pan (541 02) and the plastic rod with bearing pan (541 05) in electrostatics experiments. 1 Safety note 2 Description 2.1 Magnetic needle (513 11) Magnetic needle, approx. 7.5 cm long, one half bare metal (south pole), the other dark (north pole); with agate bearing. 2.2 Base for magnetic needle (513 51) Needle with hardened tip, on stand (height approx. 6.5 cm); with protection cap for the tip. 3 Magnetizing the magnetic needle withthecorrect polarity Place the magnetic needle in a coil with 500 turns (562 14) as shown in Fig. 2 so that the north pole is at the connection side of the coil. Using a current of approx. 3 A (observe the polarity!) generate a magnetic field and allow this to act on the magnetic needle for approx. one minute. Die Magnetnadel (513 11) auf Fuß (513 51) dient insbesondere zu einführenden Versuchen zum Magnetismus sowie zu Versuchen mit stromdurchflossenen Leitern, Spulen und Elektromagneten. Der Fuß mit Lagerspitze (513 51) wird außerdem verwendet zum Aufsetzen des Magneten mit Hut und Polmarken (510 16) sowie von Glasrohr mit Pfanne (541 02) und Kunststoffstab mit Pfanne (541 05) bei elektrostatischen Versuchen. 1 Sicherheitshinweis 2 Beschreibung 2.1 Magnetnadel (513 11) Magnetnadel, ca. 7,5 cm lang, zur Hälfte metallisch-blank (Süd- pol) bzw. dunkel (Nordpol); mit Lagerpfanne aus Achat 2.2 Fuß mit Lagerspitze Nadel mit gehärteter Spitze in Ständer (ca. 6,5 cm hoch); mit Kappe zum Abdecken der Spitze. 3 Polrichtiges Aufmagnetisieren der Magnetnadel Magnetnadel gemäß Fig. 2 so in eine Spule mit 500 Windungen (562 14) legen, daß sich der Nordpol auf der Anschlußseite der Spule befindet. Mit einem Gleichstrom von ca. 3 A (Polarität beachten!) ein Magnetfeld erzeugen und etwa 1 min auf die Magnetnadel einwirken lassen. Magnetnadel Fuß mit Lagerspitze Magnetic Needle Base for Magnetic Needle Fig. 1 Do not expose the magnetic needle to strong constant or alter- nating magnetic fields (this could demagnetize or reverse the polarity of your magnetic needle). Magnetnadel keinen starken magnetischen Gleich- bzw. Wechselfeldern aussetzen (Gefahr der Um- bzw. Ent- magnetisierung) Fig. 2 LEYBOLD DIDACTIC GMBH Leyboldstrasse 1 D-50354 Hürth Phone (02233) 604-0 Telefax (02233) 604-222 Telex 17 223 332 LHPCGN D  © by Leybold Didactic GmbH Printed in the Federal Republic of Germany Technical alterations reserved

Transcript of Ago Bussola

Page 1: Ago Bussola

7/30/2019 Ago Bussola

http://slidepdf.com/reader/full/ago-bussola 1/1

Physik Chemie ⋅ Biologie Technik  LEYBOLD DIDACTIC GMBH

8/95

Gebrauchsanweisung 513 11/51Instruction Sheet

The magnetic needle (513 11) on base (513 51) is particularlysuitable for introductory experiments on magnetism, and for ex-periments with current-carrying conductors, coils and electro-magnets.

The base for the magnetic needle (513 51) can also be used asa support for the magnet with cap and pole marks (510 16) aswell as for the glass tube with bearing pan (541 02) and theplastic rod with bearing pan (541 05) in electrostatics experiments.

1 Safety note

2 Description

2.1 Magnetic needle (513 11)

Magnetic needle, approx. 7.5 cm long, one half bare metal(south pole), the other dark (north pole);with agate bearing.

2.2 Base for magnetic needle (513 51)

Needle with hardened tip, on stand (height approx. 6.5 cm);with protection cap for the tip.

3 Magnetizing the magnetic needle with the correct polarity

Place the magnetic needle in a coil with 500 turns (562 14) asshown in Fig. 2 so that the north pole is at the connection side ofthe coil. Using a current of approx. 3 A (observe the polarity!)generate a magnetic field and allow this to act on the magneticneedle for approx. one minute.

Die Magnetnadel (513 11) auf Fuß (513 51) dient insbesonderezu einführenden Versuchen zum Magnetismus sowie zu Versuchenmit stromdurchflossenen Leitern, Spulen und Elektromagneten.

Der Fuß mit Lagerspitze (513 51) wird außerdem verwendetzum Aufsetzen des Magneten mit Hut und Polmarken (510 16)sowie von Glasrohr mit Pfanne (541 02) und Kunststoffstab mitPfanne (541 05) bei elektrostatischen Versuchen.

1 Sicherheitshinweis

2 Beschreibung

2.1 Magnetnadel (513 11)

Magnetnadel, ca. 7,5 cm lang, zur Hälfte metallisch-blank (Süd-pol) bzw. dunkel (Nordpol);mit Lagerpfanne aus Achat

2.2 Fuß mit Lagerspitze

Nadel mit gehärteter Spitze in Ständer (ca. 6,5 cm hoch);mit Kappe zum Abdecken der Spitze.

3 Polrichtiges Aufmagnetisieren der Magnetnadel

Magnetnadel gemäß Fig. 2 so in eine Spule mit 500 Windungen(562 14) legen, daß sich der Nordpol auf der Anschlußseite derSpule befindet. Mit einem Gleichstrom von ca. 3 A (Polaritätbeachten!) ein Magnetfeld erzeugen und etwa 1 min auf dieMagnetnadel einwirken lassen.

MagnetnadelFuß mit Lagerspitze

Magnetic NeedleBase for Magnetic Needle

Fig. 1

Do not expose the magnetic needle to strong constant or alter-nating magnetic fields (this could demagnetize or reverse

the polarity of your magnetic needle).

Magnetnadel keinen starken magnetischen Gleich- bzw.Wechselfeldern aussetzen (Gefahr der Um- bzw. Ent-

magnetisierung)

Fig. 2

LEYBOLD DIDACTIC GMBH ⋅ Leyboldstrasse 1 ⋅ D-50354 Hürth ⋅ Phone (02233) 604-0 ⋅ Telefax (02233) 604-222 ⋅ Telex 17 223 332 LHPCGN D

 © by Leybold Didactic GmbH Printed in the Federal Republic of GermanyTechnical alterations reserved