Philips Mini300 LED gen2 BBP400/BCS400/BVS400 BCS400...Istruzioni di montaggio Instrucciones de...
Transcript of Philips Mini300 LED gen2 BBP400/BCS400/BVS400 BCS400...Istruzioni di montaggio Instrucciones de...
IECEN60598
IK08IP65
Philips Mini300 LED gen2 BBP400/BCS400/BVS400Mounting instructionsInstructions de montage
Montagenleitung
Montage instruktie
Istruzioni di montaggio
Instrucciones de montaje
Instruções de montagem
Monteringsinstruktioner
Monteringsvejledning
Kokoonpano- ja kiinnitysohjeet
Montaj yönergesi
Monteringsinstruktioner
Instrukcja montazu
12NC 4427 100 66746Version date: /11 2017Data subject to chance without noticePrinted in Polandwww.philips.com/lighting
BVS400
L
N
L N
max 5 x 2,5 mm2
5
5
25
min 5 max 13L
L
N
N
click
5
5a
MAINS AC / / VDALI 1-10
L N
max 3 x 2,5 mm2
5
5
25
min 5 max 13
x 2 5-10Nm
x 4
4a
4c
4
L N
max 3 x 2,5 mm2
25
5
5
min 6 max 12
L N DA DA- -+ +
L N LN LNDA DA
L N
max 5 x 2,5 mm2
5
5
25
min 6 max 12
85 mm
145 mm
270 mm
BCS400
inrush current(A /50%- s)pk µ
7 90A/1 0
Max
17
220 V
240 V
50 Hz
60 Hz
x 2 1,5Nm
4d
4b
5b
5c
PH2
min 30 cm min 36 cm 4-5 m
8,9 40 40 9
9 40 40 9
9 40 40 9
9,1 40 40 9
9,1 40 40 9
8,9 40 40 9
9 40 40 9
9 40 40 9
9,1 35 40 9
9,1 30 40 9
8,3 40 40 9
8,5 40 40 9
8,5 40 40 9
8,6 40 40 9
8,6 40 40 9
8,3 40 40 9
8,5 40 40 9
8,5 40 40 9
8,6 35 40 9
8,6 25 35 9
8,8 40 40 9
8,9 40 40 9
8,9 40 40 9
9 40 40 9
9 40 40 9
8,8 40 40 9
8,9 40 40 9
8,9 40 40 9
9 35 40 9
9 30 40 9
BVS400
Green line (GRN)
Economy line (ECO)
BBP400
BCS400
Max No of luminaires*on MCB 16A/230V
Green line (GRN)
Green line (GRN)
Economy line (ECO)
Economy line (ECO)
Max
!
757 740 +/- 10%
MAINS AC
MAINS AC / / VDALI 1-10 MAINS AC
* Depends on the parasitic capacity and inductance of the power mains network
+/- 10%
Min
-30
GRN52 33
GRN62 36
GRN73 42
GRN83 47
GRN94 57
ECO75 49
ECO106 68
ECO121 75
ECO136 82
ECO151 94
GRN49
GRN59
GRN68
GRN78
GRN88
ECO71
ECO99
ECO113
ECO127
ECO142
37
39
46
52
64
54
74
85
136
104
GRN52 33
GRN62 36
GRN73 42
GRN83 47
GRN94 57
ECO75 49
ECO106 68
ECO121 75
ECO136 82
ECO151 94
GRN49
GRN59
GRN68
GRN78
GRN88
ECO71
ECO99
ECO113
ECO127
ECO142
37
39
46
52
64
54
74
85
136
104
GRN52 33
GRN62 36
GRN73 42
GRN83 47
GRN94 57
ECO75 49
ECO106 68
ECO121 75
ECO136 82
ECO151 94
GRN49
GRN59
GRN68
GRN78
GRN88
ECO71
ECO99
ECO113
ECO127
ECO142
37
39
46
52
64
54
74
85
136
104
2 m
3
BBP400a
b
x 4 0,5 - 1,5Nm
x 4 1,5Nm
3a
3b
3c
3d
L N
max 3 x 2,5 mm2
25
5
5
min 5 max 13
max 2 x 2,5 mm2
25
5
min 5 max 13 DA / 1-10V -( )
DA / 1-10V +( )
L
L
N
N
DALI /1-10V
BBP400
BVS400
BCS400
1
260 mm
210 mm
440 mm
152 mm
95 mm
413 mm
374 mm
374 mm 374 mm
374 mm
413 mm
a bCFRM 1 360 mm 360 mmCFRM 2 470 mm 470 mmCFRM 3 410 mm 560 mm
!
2
2a 2b
2c3 mm PH2
PH2
!
MAINS AC
BVS 400
BBP 400
BCS 400
BCS 400 TW
D9 SNS
SNS
D9 SNS
MAINS AC
MAINS AC
MAINS AC
MAINS AC + DALI
DALI
DALI
I = 16A max
MWS
MWS
MWS
1pce max 6pcs D9MASTER (MWS) - SLAVE ( SNS)
D9 SNS D9 SNS
D9 SNSD9 SNSMWS
ab
**
*SENSOR - standard factory settings
MDU PH
Fade in - 1 secFade out - 5 secDim down delay time - 3 minDim level from 100% to 30%
* For luminaire with sensor** External cable box
200 lx
MDU PH
Fade in - 1 secFade out - 5 secDim down delay time - 3 minDim level from 100% to 30%200 lx
6ab
ddd
h
LUMINAIRE POSITIONING
MOVEMENT DETECTION ZONE ( see details in sensor’s manual - 12NC: 4427 100 67750)
4,5 m
6 m
4,5 m
1,5 m
OPTICS PAM, A
PAM,A
4 x 900
DM, PRM, PRW, S PAM,A
OPTICS DM, PRM, PRW, S
Optic DM, PRM, PRW, S PAM,A
h (m) 4,5 4,5
d (m) 3 3
click6 m
This product has the option to communicate via mobile communication technology.Take careful attention to signs, instructions and safety rules, and obey these.This includes restrictions on the use of mobile phones or laptops in defined safety zones around the dispensers.Commissioning should only to be performed by certified professionals in strict accordance of local regulations and site rules.
8
7
9
10
SWPIn luminaire version for swimming pool applications (SWP):
Fixture mounting system (including fasteners) needs to be complied with EN 13451-1 or MIS 12031)Mounting system and product shall be a subject of periodical inspection at least every 3 years.2)
Any rusted element, needs to be replaced.
!