· MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA...

49
MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET D’ENTRETIEN DES VENTILO-CONVECTEURS CARISMA HANDBUCH FÜR INSTALLATION, GEBRAUCH UND WARTUNG DER GEBLÄSE-KONVEKTOREN CARISMA MANUAL DE INSTALACIÓN, USO Y MANTENIMIENTO DE LOS VENTILADORES CONVECTORES CARISMA HANDLEITUNG VOOR DE INSTALLATIE, HET GEBRUIK EN HET ONDERHOUD VAN DE VENTILATORS-CONVECTORS CARISMA Via Piave, 53 20011 Corbetta (MI) ITALY Tel. +39.02.97203.1 ric. autom. Fax +39.02.9777282 - +39.02.9772820 E-mail: [email protected] Internet: www.sabiana.it C 07/10 E 07/10 Cod. 4050850 Ventil Carisma CRC MV – MVB MO – IV – IO

Transcript of  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA...

Page 1:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

MANUALE DI INSTALLAZIONE,USO E MANUTENZIONE DEI VENTILCONVETTORI

CARISMA

FAN COIL CARISMA INSTALLATION,USE AND MAINTENANCE MANUAL

MANUEL D’INSTALLATION, D’UTILISATIONET D’ENTRETIEN DES VENTILO-CONVECTEURS

CARISMA

HANDBUCH FÜR INSTALLATION,GEBRAUCH UND WARTUNG

DER GEBLÄSE-KONVEKTOREN CARISMA

MANUAL DE INSTALACIÓN, USO Y MANTENIMIENTODE LOS VENTILADORES CONVECTORES

CARISMA

HANDLEITUNG VOOR DE INSTALLATIE, HET GEBRUIKEN HET ONDERHOUD VAN DE VENTILATORS-CONVECTORS

CARISMA

Via Piave, 53 • 20011 Corbetta (MI) • ITALYTel. +39.02.97203.1 ric. autom. • Fax +39.02.9777282 - +39.02.9772820

E-mail: [email protected] • Internet: www.sabiana.it

C 07/10E 07/10

Cod. 4050850

Ventil CarismaCRC

MV – MVBMO – IV – IO

Page 2:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

ScopoIdentificazione macchinaTrasportoPesie dimensioni unità imballataNote generali alla consegnaAvvertenze generaliRegole fondamentali di sicurezzaPrescrizioni di sicurezzaLimiti di impiegoSmaltimentoCaratteristiche tecnicheInstallazione meccanicaCollegamento idraulicoCollegamenti elettrici

Comandi e schemi elettriciLegenda

Pulizia, manutenzione, ricambiRicerca guastiPerdite di carico lato acquaDichiarazione di conformità

ApplicationIdentifying the applianceTransportWeightsand dimension packed unitGeneral notes on deliveryGeneral warningsFundamental safety rulesSafety rulesOperating limitsWaste disposalTechnical characteristicsMechanical installationHydraulic connectionsElectrical connectionsElectricalcontrols and wiring diagramsLegendCleaning,maintenance and spare partsTroubleshootingPressure drop tableDeclaration of conformity

ButIdentification des machinesTransportPoidset dimensions de l’unité emballéeRemarques générales pour la livraisonGénéralitésRègles fondamentales de sécuritéConsignes de securitéLimites d’emploiÉliminationCaractéristiques techniquesInstallation mécaniqueRaccordement hydrauliqueBranchements électriquesCommandeset schémas électriquesLégendeNettoyage,entretien et pièces de rechangeDépannagePertes de charge côté eauDéclaration de conformité

ZweckbestimmungKennzeichnung des GerätsTransportGewichtund dimensionen verpacktes gerätAllgemeine Hinweise zur LieferungAllgemeine HinweiseGrundsätzliche SicherheitsvorschriftenSicherheitsvorschriftenEinsatzgrenzenEntsorgungTechnische MerkmaleMechanische InstallationWasseranschlussElektroanschlüsse

Steuerungen und SchaltpläneLegende

Reinigung, Wartung, ErsatzteileFehlersucheWasserseitige DruckverlusteKonformitätserklärung

ObjetivoIdentificación máquinaTransportePesoy dimensión unidad embaladoNotas generales para la entregaAdvertencias generalesNormas fundamentales de seguridadPrescripciones de seguridadLímites de usoEliminaciónCaracterísticas técnicasInstalación mecánicaConexión hidráulicaConexiones eléctricasMandosy esquemas eléctricosLeyenda

Limpieza, mantenimiento, recambioBúsqueda de averíasPérdidas de carga lado aguaDeclaración de conformidad

DoelIdentificatie apparaatTrasportoPesie dimensioni unità imballataAlgemene opmerkingen bij de leveringAlgemene voorschriftenBelangrijke veiligheidsvoorschriftenVeiligheids-voorschriftenGebruikslimietenAfdankingTechnische karakteristiekenMechanische installatieHydraulische aansluitingElektrische aansluitingenBedieningenen schakelschema’sLegendeSchoonmaak,onderhoud, wisselstukkenOpsporen defectenWaterlekkenConformiteitsverklaring

234

4556799

10121317

1819

43444546

234

4556799

10121317

1819

43444546

234

4556799

10121317

1819

43444546

234

4556799

10121317

1819

43444546

234

4556799

10121317

1819

43444546

234

4556799

10121317

1819

43444546

2 2A

INDICE

SCOPO

INDEX

APPLICATION

TABLE DES MATIÈRES INHALT ÍNDICE INHOUD

BUT ZWECKBESTIMMUNG OBJETIVO DOEL

PRIMA DI INSTALLAREL’APPARECCHIO

LEGGERE ATTENTAMENTEQUESTO MANUALE

CAREFULLYREAD THIS MANUALBEFORE INSTALLING

THE APPLIANCE

AVANT D’INSTALLERL’APPAREIL

LIRE ATTENTIVEMENTCE MANUEL

BEVOR DAS GERÄTINSTALLIERT WIRD, SOLLTEDIESES HANDBUCH SORG-FÄLTIG GELESEN WERDEN

ANTES DE INSTALAREL APARATO

LEA ATENTAMENTEESTE MANUAL

VÓÓR DE INSTALLATIEVAN HET APPARAAT

NEEMT U AANDACHTIGDEZE HANDLEIDING DOOR

I Ventilconvettori sono stati ideati,progettati e costruiti per riscalda-re/raffrescare qualsiasi ambientecivile, industriale, commerciale esportivo.

L’apparecchionon può essere impiegato:• per il trattamento dell’aria all’aperto• per l’installazione in ambienti umidi• per l’installazione in atmosfere esplosive• per l’installazione in atmosfere corrosive

Verificare che l’ambiente in cuiè installato l’apparecchio noncontenga sostanze che generinoun processo di corrosione dellealette in alluminio.

Gli apparecchi sono alimentati conacqua calda/fredda a seconda chesi voglia riscaldare o raffrescarel’ambiente.

L’apparecchio non è destinato adessere usato da persone (bambinicompresi) le cui capacità fisiche,sensoriali o mentali siano ridotte,oppure con mancanza di esperienzao di conoscenza, a meno che esseabbiano potuto beneficiare, attra-verso l’intermediazione di una perso-na responsabile della loro sicurezza,di una sorveglianza o di istruzioniriguardanti l’uso dell’apparecchio.

I bambini devono essere sorvegliatiper sincerarsi che non giochino conl’apparecchio.

The fan coils are conceived, designedand produced to heat/cool all civil,industrial, commercial or sportspremises.

The appliancemay not be used:• for outdoor air treatment

• for installation in moist rooms

• for installation in explosive atmospheres• for installation in corrosive atmospheres

Make sure that the environmentwhere the appliance is installeddoes not contain substancesthat cause the corrosion of thealuminium fins.

The units are supplied with hot orcold water, depending on whetherthe environment is to be heatedor cooled.

This appliace is not intended foruse by persons (including children)with reduced physical, sensory ormental capabilities, or lack ofexperience and knowledge, unlessthey have been given supervisionor instruction concerning use of theappliance by a person responsiblefor their safety.

Children should be supervised toensure that they do not play withthe appliance.

Les ventilo-convecteurs ont été conçuset construits pour chauffer/rafraîchirn’importe quelle ambiance civile,industrielle, commerciale et sportive.

L’appareil ne peut pas:• pour le traitement de l’air en plein air• être installé dans des locaux humides• être installé dans des atmosphères explosives• être installé dans des atmosphères corrosives

Vérifier que la pièce dans laquellel’appareil est installé ne contientpas de substances pouvant en-gendrer la corrosion des ailettesen aluminium.

Les appareils sont alimentés avecde l’eau chaude/froide selon qu’onveut chauffer ou rafraîchir l’ambiance.

L’appareil n’est pas prévu pour êtreutilisé par des personnes (y comprisles enfants) dont les capacités physi-ques, sensorielles ou mentales sontréduites, ou dénuées d’expérienceou de connaissance, sauf si ellesont pu bénéficier, par l’intermédiaired’une personne responsable deleur sécurité, d’une surveillance oud’instructions préalables concernantl’utilisation de l’appareil.

Il convient de surveiller les enfantspour s’assurer qu’ils ne jouent pasavec l’appareil.

Die Gebläsekonvektoren wurdenkonzipiert, entworfen und gebaut,um zivil, industriell, gewerblich undzu sportlichen Zwecken genutzteRäume zu heizen bzw. zu kühlen.

Die Geräte darf nichteingesetzt werden für:• die Aufbereitung der Luft im Freien• die Installation in feuchten Räumen• die Installation in explosiver Atmosphäre• die Installation in korrosiver Atmosphäre

Überprüfen, dass der Raum, indem das Gerät installiert wird,keine Stoffe enthält, die einenKorrosionsprozess der Aluminium-rippen bewirken.

Je nachdem, ob der Raum geheiztoder gekühlt werden soll, werdendie Geräte mit warmem oder kaltemWasser versorgt.

Dieses Gerät ist nicht dafür bestimmt,durch Personen (einschließlich Kinder),mit eingeschränkten physischen,sensorischen oder geistigen Fähig-keiten oder mangels Erfahrungund/oder mangels Wissen benutztzu werden, es sei denn sie werdendurch eine für ihre Sicherheitzuständige Person beaufsichtigtoder erhielten von ihr Anweisungen,wie das Gerät zu benutzen ist.

Kinder sollten beaufsichtigt werden,um sicherzustellen, dass sie nichtmit dem Gerät spielen.

Los fan coils han sido diseñados,proyectados y construidos paracalentar/refrescar toda clase deambiente domestico, industrial,comercial y deportivo.

Los aparatosno se pueden usar para:• el tratamiento del aire al aire libre• su instalación en locales húmedos• su instalación en atmósferas explosivas• su instalación en atmósferas corrosivas

Compruebe que la estancia en laque se está instalado el aparatono contenga sustancias quegeneren un proceso de corro-sión de las aletas de aluminio.

Los aparatos están alimentados conagua caliente/fría según se deseecalentar o refrescar el ambiente.

Este aparato no debe ser utilizadopor personas (incluidos niños) cuyascapacidades físicas, sensoriales omentales estén disminuidas o quecarezcan de experiencia y cono-cimientos, al no ser que ellas hayanpodido beneficiar, a través de laintermediación de una personaresponsable de su seguridad, deuna vigilancia o de instruccionesrelativas al uso del aparato.

Los niños han de vigilarse paraasegurarse de que no jueguen conel aparato.

De ventilatorconvectors werdenontworpen om privé-ruimtes, industriële,commerciële en sportieve ruimteste verwarmen/af te koelen.

De ventilators-convectorsmag niet worden gebruikt:• voor de zuivering van de buitenlucht• voor installatie in vochtige ruimten• voorinstallatie in ruimten waar ontploffingsgevaar heerst• voor installatie in corrosieve omgevingen

Controleer of de omgeving waarinhet apparaat geïnstalleerd is geenstoffen bevat die een roestprocesvan de aluminium ribben op gangbrengen.

De apparaten worden gevoed metwarm/koud water, naargelang mende ruimte wenst af te koelen of teverwarmen.

Het apparaat is niet bestemd voorgebruik door personen (kindereninbegrepen) met beperkte fysieke,sensoriële of mentale capaciteitenof met onvoldoende ervaring ofkennis, tenzij ze gebruik hebbenkunnen maken, dankzij het toedoenvan iemand die verantwoordelijk isvoor hun veiligheid, van toezichtof aanwijzingen over het gebruikvan het apparaat.

Kinderen dienen onder toezicht testaan om zich ervan te verzekerendat zij niet met het apparaat spelen.

Page 3:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

COD.

4050

065

230V 50Hz

230V 50Hz

MAX Assorbimento - MAX Power Input (Watt)

MAX Assorbimento - MAX Power Input (Watt)

20watt

27watt

38watt

50watt

58watt

71watt

1 2 3 4 5 6

ModelloModel

RanghiRows

GIORNO DAYANNO YEAR MESE MONTH

CRT

MO-MVB

MV

4

3

4+1

3+1 3+2IV-IO

SABIANA S.p.A. - MADE IN ITALY

10 11 12 1 2 3 4 5 6 7 8 9 101112

33watt

32watt

41watt

44watt

46watt

78watt

103watt

130watt

176watt

1 2 3 4 5 6 7 8 9CRC

FAN COIL CARISMA

IL COMFORT AMBIENTALE

A bordo di ogni singola macchinaè applicata l’etichetta di identifica-zione riportante i dati del costrut-tore ed il tipo di macchina.

L’etichetta è posizionata sul latodei comandi elettrici, all’internodell’apparecchio.

Each unit is supplied with anidentification plate giving detailsof the manufacturer and the typeof appliance.

The label is located inside theappliance on the electric controlsside.

Une étiquette d’identification estappliquée sur chaque machine; elleindique les données du constructeuret le type de machine.

Cette étiquette se trouve sur lecôté des commandes électriques,à l’intérieur de l’appareil.

Jedes Gerät ist mit einem Typen-schild gekennzeichnet, auf demdie Daten des Herstellers und derTyp des Geräts angegeben sind.

Das Schild befindet sich auf derSeite der elektrischen Steuerungen,im Geräteinnern.

Cada máquina lleva una placa deidentificación en la que figuran losdatos del fabricante y el tipo demáquina de que se trata.

La etiqueta está emplazada en ellado de los dispositivos de acciona-miento eléctricos, dentro del aparato.

Aan boord van elk apparaat wordteen identificatielabel aangebrachtmet de gegevens van de fabrikanten het type machine.

De label wordt aangebracht op dezijkant van de elektrische bedieningen,aan de binnenkant van het apparaat.

3 3A

I componenti principali sono:MOBILETTO DI COPERTURA ditipo misto in lamiera d’acciaio zin-cata a caldo preverniciata e spallein materiale sintetico antiurto. Èfacilmente smontabile per una com-pleta accessibilità dell’apparecchio.

La griglia di mandata dell’aria, fa-cente parte del mobiletto, è di tiporeversibile ad alette fisse e posi-zionato sulla parte superiore.

GRUPPO VENTILATORECostituito da ventilatori centrifughia doppia aspirazione, particolar-mente silenziosi con giranti in allu-minio bilanciate staticamente e di-namicamente, direttamente calet-tate sull’albero motore.

MOTORE ELETTRICODi tipo monofase a 6 velocità (dicui 3 collegate), montato su suppor-ti elastici antivibranti e con conden-satore permanentemente inserito,protezione termica interna a riar-mo automatico, grado di protezioneIP 20 e classe B.

BATTERIADI SCAMBIO TERMICOÈ costruita con tubi di rame edalette in alluminio fissate ai tubi conprocedimento di mandrinatura mec-canica. Nella versione a 3-4 ranghila batteria è dotata di 2 attacchiØ 1/2” gas femmina. I collettori dellebatterie sono corredati di sfoghid’aria e di scarichi d’acqua Ø 1/8”gas. I Ventilconvettori possono es-sere corredati di batteria addizio-nale (solo per riscaldamento), conattacchi femmina Ø 1/2” gas (ver-sione 3 o 4 ranghi più 1 - versione3 ranghi più 2; per impianti a 4 tubi).La posizione di serie degli attacchiè a sinistra, guardando l’apparec-chio. Su richiesta, o comunque confacile operazione eseguibile in can-tiere, la posizione degli attacchi puòessere spostata a destra.

FILTRO di materiale sintetico rige-nerabile.

BACINELLARACCOLTA CONDENSA in ma-teriale plastico, realizzata a formadi L e fissata alla struttura interna.

The main components are:CASINGIn prepainted hot galvanised sheetsteel with synthetic impact resistantside panels. Easy to remove forcomplete access to the unit.

The air discharge grid incorporatedin the top of the casing is reversiblewith fixed louvres.

FAN ASSEMBLYUltra-silent double intake centrifugalfans with statically and dynamicallybalanced aluminium impellers keyeddirectly onto the motor shaft.

ELECTRIC MOTORThe motor is wired for single phaseand has six speeds (three connected)with always-on capacitor. The motoris fitted on sealed for life bearingsand is secured on anti-vibration andself-lubricating mountings. Internalthermal protection with automaticreset, protection IP 20, class B.

HEATEXCHANGE COILMade with aluminium finned coppertubes. The 3-4 row exchanger hastwo 1/2” female gas connections.Coil headers with air vents and waterdrain outlets (1/8” dia. gas). The unitscan be fitted with a supplementaryexchanger (for heating only) with1/2” dia. gas female connections(3 or 4 row plus 1 version - 3 rowplus 2 version; for 4-tube installations).As standard, the connections areon the left hand side facing the unit.The units can be supplied if specifiedwith the connections on the righthand side. Alternatively the connectionscan easily be moved from one sideto the other on site.

Regenerable synthetic FILTER.

CONDENSATEDRAIN PAN, plastic, L-shaped,fixed to internal structure.

Les composants principaux sont:CARROSSERIE de type mixte entôle d’acier zinguée à chaud pré-peinte et panneaux latéraux enmatière synthétique antichoc. Elleest facilement démontable, ce quioffre une accessibilité totale àl’appareil.

La grille de refoulement de l’air, quifait partie de la carrosserie, est dutype réversible à ailettes fixes et setrouve sur la partie supérieure.

GROUPE VENTILATEURConstitué par des ventilateurs centri-fuges à double aspiration, particuliè-rement silencieux, avec des turbinesen aluminium équilibrées statique-ment et dynamiquement, directe-ment fixées sur l’arbre moteur.

MOTEUR ÉLECTRIQUEDe type monophasé à 6 vitesses(dont 3 raccordées), monté sursupports antivibratiles et avec con-densateur permanent, protectionthermique à réarmement auto-matique, protection IP 20 et classe B.

BATTERIED’ÉCHANGE THERMIQUEConstruite avec des tubes en cuivreet des ailettes en aluminium fixéesaux tubes par dudgeonnage méca-nique. Dans la version à 3-4 rangs,la batterie est équipée de deuxraccords Ø 1/2” gaz femelle. Lescollecteurs des batteries sont dotésde purgeurs d’air et de sorties d’eauØ 1/8” gaz. Les ventilo-convecteurspeuvent être équipés d’une batteriesupplémentaire (seulement pourle chauffage), avec des raccordsfemelle Ø 1/2” gaz (version 3 ou 4rangs plus 1 - version 3 rangs plus 2;pour installations à 4 tuyauteries). Laposition standard des raccords est àgauche, quand on regarde l’appareil.Sur demande ou par une simpleopération pouvant être pratiquée enchantier, la position des raccordspeut-être déplacée à droite.

FILTRE en matière synthétiquerégénérable.

BAC DE RECUPERATIONDES CONDENSATS, en matièreplastique, réalisé en forme de “L“et fixé à la structure interne.

Das Gerät setzt sich hauptsächlichaus folgenden Bauteilen zusammen:GEHÄUSE aus feuerverzinktem undvorlackiertem Stahlblech mit Seiten-teilen aus stoßfestem Kunststoff. DasGehäuse kann vollständig abgenommenwerden, um ungehindert Zugangzum Gerät zu haben.

Das Ausblasgitter mit festen Luft-leitlamellen, das Teil des Gehäusesist, ist umsteckbar und befindet sichauf der Geräteoberseite.

GEBLÄSEBestehend aus besonders geräu-scharmen, doppelseitig saugendenRadialventilatoren mit statisch unddynamisch ausgewuchteten Lauf-rädern aus Aluminium, direkt aufder Antriebswelle sitzend.

ELEKTROMOTOREinphasenmotor mit sechs Drehzahl-stufen (drei davon werkseitingangeschlossen), auf elastischenSchwingungsdämpfern montiertund mit permanent eingeschaltetemKondensator, Wärmeschutz mit auto-matischer Rückstellung, SchutzartIP 20, Klasse B.

WÄRMETAUSCHER-BATTERIEBestehend aus Kupferrohren mitmaschinell aufgezogenen Aluminium-lamellen. Die 3- und 4- reihigen Wärme-tauscher sind mit zwei Anschlüssenmit Innengewinde ø 1/2” Gas versehen.Die Sammler der Wärmetauschersind mit Entlüftungsöffnungen undWasserablass-Anschlüssen ø 1/8” Gasversehen. Die Geräte können miteinem Zusatz-Wärmetauscher (nurfür Heizung) mit Innengewinde-Anschlüssen ø 1/2” Gas ausgestattetwerden (Ausführung 3 oder 4 plus1 Reihe - Ausführung 3 plus 2 Reihen;für 4-Leiter-System). Serienmäßigbefinden sich die Anschlüsse vonvorne gesehen links. Auf Anfrageoder mit einem einfachen Eingriffder direkt vor Ort durchgeführtwerden kann, können die Anschlüsseauf die rechte Seite verlegt werden.

FILTER aus regenerierbaremSynthetikmaterial.

An der Innenstruktur befestigte,L-förmige KONDENSATWANNEaus Kunststoff.

Los componentes principales son:MUEBLE DE COBERTURA de tipomixto en plancha de acero zincadaen caliente prebarnizada y espaldasen material sintético antichoque. Esfácilmente desmontable para teneracceso completo al aparato.

La rejilla de impulsión del aire, queforma parte del mueble, es del tiporeversible con aletas fijas y estáemplazada en la parte superior.

GRUPO VENTILADORFormado por ventiladores centrífu-gos de doble aspiración, particular-mente silenciosos. Los rodetes sonen aluminio balanceados, estáticay dinámicamente, y ensambladosdirectamente en el eje motor.

MOTOR ELÉCTRICOEl motor eléctrico es monofásico con6 velocidades (de las cuales 3 rela-cinadas), montado sobre soporteselásticos amortiguadores de vibra-ciones y con condensador perma-nentemente activado, proteccióntérmica de rearme automático, gradode protección IP 20 y clase B.

BATERÍADE INTERCAMBIO TÉRMICOSe compone de tubos de cobre yaletas en aluminio fijadas a los tu-bos con un procedimiento de man-drilado mecánico. En la variante con3-4 filas la batería tiene 2 conexionesØ 1/2” gas hembra. Los colectoresde las baterías tienen alivios de airey descargas de agua Ø 1/8” gas.Los fan coils pueden venir equipa-dos con batería adicional (solamen-te para la calefacción), con conexio-nes hembra Ø 1/2” gas (variante3 ó 4 filas más 1 - variante 3 filasmás 2; para instalaciones con 4tubos). La posición predeterminadade las conexiones es en la parteizquierda mirando al aparato desdeenfrente. De todas maneras apetición, con una operación fácilrealizable en la obra, es posibledesplazar a la derecha la posiciónde las conexiones.

FILTRO en material sintéticoregenerable.

BARDEJADE CONDENSADOS, en materialplástico, con forma de “L” y asegu-rada a la estructura interna.

De voornaamste onderdelen zijn:BEHUIZINGVan het gemengde type in warm-verzinkte voorbeschilderde staalplaten.Is gemakkelijk demonteerbaar vooreen complete toegankelijkheid vanhet apparaat.

De luchtrooster maakt deel uit vande behuizing, is omkeerbaar, voorzienvan vaste ribben en bevindt zich aande bovenzijde.

VENTILATORGROEPSamengesteld door centrifuge-ventilators met dubbele aanzuiging,bijzonder geluidloos met statisch endynamisch uitgebalanceerde schoepenin aluminium, rechtstreeks bevestigdop de aandrijfas van de motor.

ELEKTRISCHE MOTOREenfasige, met 6 snelheden (waarvan3 aangesloten), gemonteerd op trilvrijeelastische dragers met ingebouwdepermanente condensator, thermischebeveiliging met automatische reset,beschermingsdraad IP20 en classi-ficatie B.

BATTERIJWARMTEWISSELINGSamengesteld uit koperen buizenen aluminium ribben die met eenmechanisch procédé aan de buizenbevestigd zijn. Voor de versie met3-4 rangen is de batterij voorzienvan 2 vrouwelijke gasaansluitingenvan Ø 1/2” . De collectors van debatterijen zijn uitgerust met lucht-uitlaten en waterafvoerpijpen vanØ 1/8” gas. De ventilatorconvectorskunnen voorzien worden van eenextra batterij, en vrouwelijke gas-aansluitingen van Ø 1/2” (versie met3 of 4 rangen plus 1 - versie met3 rangen plus 2; voor installatiesmet 4 leidingen). De seriële positievan de aansluitingen is links, alsmen vóór het apparaat staat. Opverzoek, kunnen de aansluitingennaar rechts worden verplaatst. Dezehandeling is gemakkelijk uit te voerenter plaatse.

Herbruikbare FILTER in synthetischmateriaal.

OPVANGBAKCONDENSATIEWATER, uitgevoerdin L-vorm en vastgemaakt aan debinnenstructuur.

IDENTIFICAZIONEMACCHINA

IDENTIFYINGTHE APPLIANCE

IDENTIFICATIONDES MACHINES

KENNZEICHNUNGDES GERÄTS

IDENTIFICACIÓNDE LA MÁQUINA

IDENTIFICATIEAPPARAAT

Page 4:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

600

V

Z

600

X

Y

14

15

15

14

15

16

19

22

18

21

21

27

33

24

29

22

28

34

25

30

24

30

36

27

32

25

31

37

28

33

30

37

44

34

40

39

47

55

45

52

40

48

56

46

54

MV – MO – MVB

Peso - Weight - Poids - Gewicht - Peso - Gewicht (kg)

33+13+2

44+1

1 2 3 4 5 6 7 8 9Mod.

Ran

gh

iR

ow

sR

ang

sR

eih

enF

ilas

Ran

gen

XY

260

720

260

820

260

820

260

820

260

1035

260

1035

260

1250

290

1250

290

1250

Mod.Dimensioni - Dimensions - Dimensions - Dimensionen - Dimensión - Afmetingen (mm)

1 2 3 4 5 6 7 8 9

VZ

260

720

260

820

260

1035

260

1035

260

1250

260

1250

260

1465

290

1465

290

1465

Mod.Dimensioni - Dimensions - Dimensions - Dimensionen - Dimensión - Afmetingen (mm)

1 2 3 4 5 6 7 8 9

10

11

12

11

12

15

17

20

17

20

19

25

31

22

27

20

26

32

23

28

22

28

34

25

30

23

29

35

26

31

27

34

41

31

37

35

43

51

41

48

36

44

52

42

50

IV – IO

Peso - Weight - Poids - Gewicht - Peso - Gewicht (kg)

33+13+2

44+1

1 2 3 4 5 6 7 8 9Mod.R

ang

hi

Ro

ws

Ran

gs

Rei

hen

Fila

sR

ang

en

4 4A

MV – MO – MVB

IV – IO

TRASPORTO TRANSPORT TRANSPORT TRANSPORT TRANSPORTE TRANSPORT

L’apparecchio viene imballato inscatole di cartone.

Una volta che l’apparecchio èdisinballato controllare che nonvi siano danni e che corrispondaalla fornitura.

In caso di danni o di sigla dell’ap-parecchio non corrispondente aquanto ordinato, rivolgersi al pro-prio rivenditore citando la serie eil modello.

Per il funzionamento dell’apparec-chiatura bisogna predisporre uncollegamento idraulico con la cal-daia/refrigaratore e un collegamen-to elettrico 230V monofase.

The appliance is supplied in card-board packaging.

After unpacking the appliance, makesure it is undamaged and correspondsto the unit requested.

In the event of damage or if theidentification code does notcorrespond to that ordered, contactyour dealer immediately, quotingthe series and model.

To operate the appliance, connecthydraulically to a boiler/chiller andelectrically to a 230 V single phasepower supply.

L’appareil est emballé dans desboîtes en carton.

Après avoir déballé l’appareil, contrôlerqu’il n’a subi aucun dommage etqu’il correspond bien à la fourniture.

En cas de dommages ou si le siglede l’appareil ne correspond pas àce qui a été commandé, s’adresserau revendeur en indiquant la sérieet le modèle.

Pour le fonctionnement de l’appareil,prévoir un raccordement hydrauliqueà la chaudière/centrale d’eau glacéeet un raccordement électrique 230 Vmonophasé.

Das Gerät wird in Kartons verpackt.

Kontrollieren Sie beim Auspackensofort, ob das Gerät unversehrt ist,und ob es mit den Angaben in denVersandpapieren übereinstimmt.

Falls Schäden festgestellt werdensollten, oder wenn die Artikelnummernicht mit dem bestellten Gerät über-einstimmt, wenden Sie sich bitte anIhren Händler. Geben Sie bei Rück-fragen immer Serie und Geräte-modell an.

Für den Betrieb des Geräts ist einWasseranschluss zum Heizer/Kühlersowie ein Stromanschluss (230 Veinphasig) erforderlich.

El aparato viene embalado en cajade cartón.

Cuando se desembala el aparato,es preciso comprobar que no tengadesperfectos y que se correspondacon el suministro previsto.

En caso de daños o de sigla delaparato no correspondiente con ladel pedido, dirigirse al revendedorindicando la serie y el modelo.

Para la operación del aparato espreciso predisponer un enlacehidráulico con la caldera/refrigera-dor y un enlace eléctrico mono-fásico de 230V.

Het apparaat wordt in een kartonnendoos verpakt.

Eens het apparaat van zijn verpakkingontdaan, controleert u de integriteiten conformiteit van het apparaat.

In geval van beschadigingen, ofindien het apparaat niet overeenkomtmet de bestelling, wendt u zich totuw verkoper, met vermelding vanhet serienummer en het model.

Om het apparaat in werking testellen, moet u een aansluitingvoorzien met de warmwaterketel/koelkast, een eenfasige elektrischeaansluiting van 230V.

PESIE DIMENSIONIUNITÀ IMBALLATA

WEIGHTSAND DIMENSIONSPACKED UNIT

POIDS ETDIMENSIONS DEL’UNITE EMBALLEE

GEWICHTUND DIMENSIONENVERPACKTES GERÄT

PESOY DIMENSIÓNUNIDAD EMBALADO

GEWICHTEN AFMETINGENVERPAKTE EENHEID

Page 5:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

Dopo aver aperto e tolto l’imballo,accertarsi che il contenuto sia quellorichiesto e che sia integro. In casocontrario, rivolgersi al rivenditoreove si è acquistato l’apparecchio.

I ventilconvettori sono stati studiatiper riscaldare e/o condizionare gliambienti e devono quindi essereutilizzati solamente per questo. Siesclude qualsiasi responsabilità peri danni eventuali causati da un usoimproprio.

Questo libretto deve accompagna-re sempre l’apparecchio in quantoparte integrante dello stesso.

Ogni riparazione o manutenzionedell’apparecchio deve essere ese-guita da personale specializzato equalificato.

Non si risponde in caso di danniprovocati da modifiche o manomis-sioni dell’apparecchio.

After removing the packaging, makesure the contents are as requestedand not damaged. If this is not thecase, contact the dealer where youbought the appliance.

The fan coils have been designedfor room heating and/or air conditioningand must be used exclusively for thatpurpose. We declines all responsibilityfor damage caused by their improperuse.

This booklet is an integral part ofthe appliance and must alwaysaccompany the unit.

All repairs or maintenance must beperformed by qualified specialists.

We declines all responsibility fordamage caused by modificationsor tampering with the unit.

Après avoir ouvert et retiré l’em-ballage, s’assurer que le contenuest conforme et qu’il est en parfaitétat. En cas contraire s’adresser aurevendeur où l’appareil a été acheté.

Les ventilo-convecteurs ont été conçuspour chauffer et/ou climatiser lespièces et ne doivent être destinés qu’àcet usage. Il exclut toute responsableen cas de dommages causés parun emploi anormal.

Cette notice doit toujours accompa-gner l’appareil car elle en fait partieintégrante.

Toutes les réparations ou entretiensde l’appareil doivent être effectuéspar le SAV ou par un technicienspécialisé.

On décline toute responsabilité encas de dommages provoqués pardes modifications ou altérations del’appareil.

Nach dem Auspacken kontrollieren,ob der Inhalt der Bestellung entsprichtund unversehrt ist. Im gegenteiligenFall wenden Sie sich an Ihren Händler.

Die Klimakonvektoren wurden zurHeizung und Klimatisierung vonRäumen entwickelt und dürfen folglichausschließlich zu diesem Zweckverwendet werden. Die Firma haftetnicht für eventuelle Schäden, diedurch den unzweckmäßigen Gebrauchverursacht werden.

Diese Betriebsanleitung ist wesent-licher Bestandteil des Gerätes undmuss folglich immer zusammen mitdiesem verwahrt werden.

Alle Reparaturen oder Wartung-sarbeiten müssen durch Personalder Firma oder andere fachlichqualifizierte Techniker erfolgen.

Die Firma haftet nicht für solcheSchäden, die durch die Veränderungoder die Manipulierung des Gerätsentstehen.

Después de haber retirado el em-balaje, comprobar que el contenidosea el solicitado y que esté intacto.En caso contrario, dirigirse al esta-blecimiento donde se ha compradoel aparato.

Los fan coils se han estudiado paracalentar y/o acondicionar las habita-ciones y no deben usarse para otrofin. Declinamos cualquier respon-sabilidad por los posibles dañosdebidos a un uso inadecuado.

Este manual debe acompañarsiempre al aparato ya que formaparte del mismo.

Todas las reparaciones o mante-nimiento del aparato deberán serrealizadas por personal especia-lizado y cualificado.

No se hace responsable en casode daños provocados por modi-ficaciones o manipulaciones delaparato.

Na de verpakking te hebbenverwijderd, controleren of de inhoudervan correct en onbeschadigd is.Is dit niet het geval, contact opnemenmet de verkoper of waar het apparaatwerd aangekocht.

De ventilatorconvectors werdenontworpen voor de verwarmingen/of koeling van ruimten, en dienenuitsluitend hiervoor te worden gebruikt.Wij kunnen niet aansprakelijk wordengesteld voor eventuele schade diehet gevolg is van een verkeerdgebruik van het apparaat.

Deze handleiding dient het apparaatsteeds te vergezellen, omdat heter wezenlijk deel van uitmaakt.

Reparaties of onderhoud van hetapparaat dienen uitgevoerd teworden door gespecialiseerd enopgeleid personeel.

Wij kunnen niet aansprakelijk wordengesteld voor schade die voortvloeituit aangebrachte wijzigingen.

• Apparecchio.

• Libretto di istruzioni e manutenzione.

• Appliance.

• Instruction and maintenance manual.

• Appareil.

• Instructions d’installation et d’entretien.

• Gerät.

• Gebrauchs- und Wartungsanleitung.

• Aparato.

• Manual de instrucciones y mantenimiento.

• Apparaat.

• Handleiding voor het gebruik en het onderhoud.

NOTEGENERALIALLA CONSEGNA

GENERALNOTESON DELIVERY

REMARQUESGENERALES POURLA LIVRAISON

ALLGEMEINEHINWEISEZUR LIEFERUNG

NOTASGENERALESPARA LA ENTREGA

ALGEMEINEOPMERKINGENBIJ DE LEVERING

5 5A

AVVERTENZEGENERALI

GENERALWARNINGS GENERALITES

ALLGEMEINEHINWEISE

ADVERTENCIASGENERALES

ALGEMENEVOORSCHRIFTEN

Page 6:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

6 6A

È vietato l’utilizzo del ventilconvet-tore da parte di bambini o di per-sone inabili e senza assistenza.

È pericoloso toccare l’apparecchioavendo parti del corpo bagnate edi piedi nudi.

Non effettuare nessun tipo di inter-vento o manutenzione senza averprima scollegato l’apparecchio dal-l’alimentazione elettrica.

Non manomettere o modificare idispositivi di regolazione o sicu-rezza senza essere autorizzati esenza indicazioni.

Non torcere, staccare o tirare icavi elettrici che fuoriescono dal-l’apparecchio anche se lo stessonon è collegato all’alimentazioneelettrica.

Non gettare o spruzzare acquasull’apparecchio.

Non introdurre assolutamente nien-te attraverso le griglie di aspirazio-ne e mandata aria.

Non rimuovere nessun elementodi protezione senza aver primascollegato l’apparecchio dall’ali-mentazione elettrica.

Non gettare o lasciare il materialeresiduo dell’imballo alla portata deibambini perché potenziale causadi pericolo.

Non installare in atmosfera esplo-siva o corrosiva, in luoghi umidi,all’aperto o in ambienti con moltapolvere.

Fan coils must never be used bychildren or unfit persons withoutsupervision.

It is dangerous to touch the unitwith damp parts of the body andbare feet.

Always unplug the unit from themains power supply before carryingout any type of operation ormaintenance.

Never tamper with or modifyregulation and safety deviceswithout prior authorisation andinstructions.

Never twist, detach or pull powercables, even when the unit isunplugged from the mains powersupply.

Never throw or spray water on theunit.

Never introduce foreign objectsthrough the air intake and dischargegrids.

Never remove protective elementswithout first unplugging the unitfrom the mains power supply.

Do not throw packaging materialaway or leave it within reach ofchildren as it may represent ahazard.

Do not install in explosive, corrosiveor damp environments, outdoorsor in very dusty rooms.

Le ventilo-convecteur ne doit pasêtre utilisé par des enfants ou despersonnes inaptes non assitées.

Il est dangereux de toucherl’appareil si on a des parties ducorps mouillées ou les pieds nus.

N’effectuer aucun intervention surl’appareil sans l’avoir débranchéau préalable.

Ne pas altérer ou modifier lesdispositifs de réglage ou de sécuritésans autorisation et sans instructions.

Ne pas tordre, détacher ou tirerles câbles électriques qui sortentde l’appareil même si celui-ci estdébranché.

Ne pas jeter ou vaporiser de l’eausur l’appareil.

Ne rien introduire à travers lesgrilles d’aspiration et de soufflagede l’air.

N’enlever aucune protection sansavoir au préalable débranchél’appareil.

Ne pas jeter ou laisser l’emballageà la portée des enfants car il peutreprésenter un danger.

Ne pas installer l’appareil dans uneatmosphère explosive ou corrosive,dans des lieux humides, dehors oudans des pièces où il y a beaucoupde poussière.

Der Klimakonvektor darf weder vonKindern, noch von Personen, dienicht mit seiner Bedienung vertrautsind, benutzt werden.

Das Gerät darf weder barfuß nochmit nassen oder feuchten Körper-teilen berührt werden.

Das Gerät darf erst gewartet werden,nachdem die Spannungsversorgungunterbrochen wurde.

Die Regel- und Sicherheitsein-richtungen dürfen ohne vorherigeGenehmigung Firma und derenAnleitung nicht verändert odermanipuliert werden.

Die aus dem Gerät kommendenStromkabel dürfen nicht gezogen,getrennt, verdreht werden, auchdann nicht, wenn das Gerät nicht andas Stromnetz angeschlossen ist.

Das Gerät darf nicht mit Wasserin Berührung kommen.

Keine Gegenstände durch die Luft-gitter stecken.

Die Schutzelemente dürfen erstdann entfernt werden, nachdem dieSpannungsversorgung unterbrochenwurde.

Das Verpackungsmaterial mussvorschriftsmäßig entsorgt werden,und darf nicht in die Reichweitevon Kindern gelangen, da es einepotentielle Gefahrenquelle darstellt.

Das Gerät darf nicht in explosiveroder korrosiver Atmosphäre, imFreien oder in Räumen mit starkerStaubbelastung installiert werden.

Se prohibe el uso del fan coil a losniños y a las personas incapaci-tadas no asistidas.

Es peligroso tocar el aparato te-niendo partes del cuerpo mojadasy con los pies descalzos.

No efectuar ningún tipo de inter-vención o mantenimiento sin antesde haber desconectado el aparatode la corriente eléctrica.

No manipular o modificar los dispo-sitivos de regulación o de seguridadsin la autorización y indicaciones.

No torcer, desconectar o tirar delos cables eléctricos que salen delaparato, aunque éste estuviera de-sconectado de la corriente eléctrica.

No tirar o vaporizar agua sobre elaparato.

No introducir absolutamente nadaa través de las rejillas de aspira-ción y descarga de aire.

No retirar ningún elemento de pro-tección sin antes haber desco-nectado el aparato de la corrienteeléctrica.

No tirar o dejar al alcance de losniños el material de embalaje yaque es una fuente potencial depeligro.

No instalar en una atmósferaexplosiva o corrosiva, en lugareshúmedos, al aire libre o en lugarescon mucho polvo.

De ventilatorconvector dient niette worden gebruikt door kinderenof onbekwame personen, zondertoezicht.

Het is gevaarlijk het apparaat aante raken wanneer delen van hetlichaam nat zijn of men op blotevoeten loopt.

Verricht geen handelingen ofonderhoud aan het apparaatvooraleer dit werd losgekoppeldvan het elektriciteitsnet.

De regel- of veiligheidsinrichtingenworden niet gehanteerd of gewijzigdzonder toelating.

De stroomkabels die uit het appa-raat steken, worden niet gekneld,losgekoppeld of onder trekspanninggebracht, zelfs wanneer het appa-raat niet aangesloten is op hetelektriciteitsnet.

Zorg ervoor dat het apparaat nietin contact komt met water.

Zorg ervoor dat niets door deaanzuig- en luchtinlaatrooster kandringen.

Verwijder geen enkele beveiligingalvorens het apparaat losgekoppeldte hebben van het elektriciteitsnet.

Laat het verpakkingsmateriaalniet rondslingeren of binnen hetbereik van kinderen, omdat hetgevaarlijk kan zijn.

Stel het apparaat niet op in eenexplosieve of corrosieve omgeving,op een vochtige plaats, buiten ofin ruimten met veel stof.

REGOLEFONDAMENTALIDI SICUREZZA

FUNDAMENTALSAFETY RULES

RÈGLESFONDAMENTALESDE SÉCURITÉ

GRUNDSÄTZLICHESICHERHEITS-VORSCHRIFTEN

NORMASFUNDAMENTALESDE SEGURIDAD

BELANGRIJKEVEILIGHEIDS-VOORSCHRIFTEN

Page 7:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

7 7A

Prima di effettuare qualsiasi inter-vento assicuratevi che:

1 - Il ventilconvettore non sia sotto tensione elettrica.2 - Chiudere la valvola di alimen- tazione dell’acqua della batte- ria e lasciarla raffreddare.

3 - Installare in prossimità dell’ap- parecchio o degli apparecchi in posizione facilmente acces- sibile un interruttore di sicu- rezza che tolga corrente alla macchina.

Durante l’installazione, la manuten-zione e la riparazione, per motivi disicurezza, è necessario attenersia quanto segue:

• Utilizzare sempre guanti da lavoro. • Non esporre a gas infiammabili. • Non posizionare sulle griglie oggetti.

Assicurarsidi collegare la messa a terra.

Nel caso di installazione di ventilin versione MV o MVB senza co-mando a bordo, fissare lo sportellocon una vite 2,2x9,5 mm.

Per ragioni di sicurezza è tassa-tivo montare le chiusure inferiorinel caso di installazioni di appa-recchi MV senza piedi. Le chiusu-re impediscono che si possa rag-giungere con le mani parti internedei vani tecnici e parti sotto tensio-ne. Il mancato montaggio di que-ste chiusure è di grave pregiudizioper la sicurezza delle persone.

Before carrying out any operationon the appliance, make sure:

1 - The unit is disconnected from the electrical power supply.2 - The coil water supply valve is closed and the coil has cooled down.

3 - Install a safety switch to turn off current to the appliance in an easily accessible position near the unit or units.

During installation, maintenance andrepairs, for safety reasons, observethe following precautions:

• Always use work gloves.

• Do not expose to inflammable gas. • Do not place objects over the grids.

Make surethe unit is earthed.

In case of installation of fan coilversion MV or MVB without onboardcontrol, fasten the control openingwith a 2.2 x 9.5 mm screw.

For safety reasons, the bottompanels must be fitted when installingMV version appliances without feet.The panels prevent the parts insidethe technical compartment an thelive parts from being accessible tothe hands. Failure to fit these panelsrepresents a serious risk to personalsafety.

Avant d’effectuer toute intervention,s’assurer que:

1 - Le ventilo-convecteur n’est pas sous tension électrique.

2 - Fermer la vanne d’alimentation de l’eau de la batterie et la laisser refroidir.3 - Installer à proximité du ou des appareils et dans une position facilement accessible un inter- rupteur de sécurité pour couper le courant de la machine.

Pendant l’installation, l’entretienet la réparation, pour des raisonsde sécurité, il est nécessaire derespecter ce qui suit:

• Utiliser toujours des gants de travail. • Ne pas exposer à des gaz inflammables. • Ne placer aucun objet sur les grilles.

S’assurer que la mise à la terrea été effectuée.

En cas d’installation de ventil enversion MV ou MVB sans commandeà bord, fixer l’ouverture pour lacommande avec une vis 2,2 x 9,5mm.

Pour des raisons de sécurité il estimpératif de monter les protectionsinférieures en cas d’installationd’appareils MV sans pieds. Lesprotections empêchent d’accéderaux compartiments techniques etaux parties sous tension. L’absencede ces protections peut avoir degraves conséquences sur la sécuritédes personnes.

Vor Durchführung irgendwelcherEingriffe:

1 - Sicherstellen, dass der Gebläse- konvektor nicht unter Spannung steht.2 - Das Wassereinlassventil der Batterie schließen und abkühlen lassen.3 - An einer gut zugänglichen Stelle in der Nähe des Geräts bzw. der Geräte einen Sicherheitsschalter installieren, der die Stromzufuhr zum Gerät unterbricht.

Aus Gründen der Sicherheit sindwährend der Installation, Wartungund Reparaturen, die folgendenVorschriften einzuhalten:

• Stets Arbeitshandschuhe tragen. • Keinen feuergefährlichen Gasen aussetzen. • Nichts auf die Ausblasgitter stellen.

Vergewissern Sie sich, dass dasGerät korrekt geerdet wird.

Bei Installation der Ventil-konvektorenin der Ausführung MV oder MVBohne Steuerung die Klappe mit einerSchraube zu 2,2 x 9,5mm befestigen.

Aus Sicherheitsgründen müssenbei der Installation von Geräten MVohne Füße die unteren Verschlüsseunbedingt montiert werden. DieVerschlüsse verhindern den Zugriffauf die Geräteinnenteile und dieunter Spannung stehenden Teile mitden Händen. Wenn diese Verschlüssenicht montiert werden, ist die Personen-sicherheit stark beeinträchtigt.

Antes de efectuar cualquier ope-ración es preciso comprobar que:

1 - El fan coil no está alimentado eléctricamente.2 - Cerrar la válvula de alimenta- ción del agua de la batería y dejar que se enfríe.

3 - Instalar cerca del aparato o de los aparatos, en una posición a la que se acceda fácilmente, un interruptor de seguridad que desconecte la alimentación de la máquina.

Durante la instalación, el manteni-miento y repación, por motivos deseguridad, es necesario atenersea los siguiente:

• Usar siempre guantes de trabajo. • No exponer a gases inflamables. • No dejar objetos sobre las rejillas.

Comprobar siempre queesté conectada la toma de tierra.

En caso de instalar ventil en versiónMV o MVB sin mando a bordo, fijarla apertura de comando con un tor-nillo de 2,2 x 9,5 mm.

Por razones de seguridad es obli-gatorio montar los cerramientosinferiores en caso de instalacionesde aparatos MV sin pies. Los cerra-mientos impiden que se puedanalcanzar con las manos las partesinternas de las aperturas técnicasy las partes bajo tensión. No realizarel montaje de estos cerramientossupone un grave perjuicio para laseguridad de las personas.

Alvorens u een handeling uitvoert aanhet apparaat, vergewis u ervan dat:

1 - De ventilatorconvector niet onder elektrische spanning staat.2 - De watertoevoerklep van de batterij gesloten is. Laat deze laatste afkoelen.

3 - Installeer vlakbij het apparaat of de apparaten een makkelijk bereikbare noodschakelaar die de stroomtoevoer naar de machine onderbreekt.

Tijdens de installatie, het onderhouden de reparaties, is het uit veiligheids-overwegingen noodzakelijk na televen wat volgt:

• Gebruik altijd werkhandschoenen. • Niet blootstellen aan brandbare gassen. • Geen voorwerpen op de roosters plaatsen.

Zorgvoor een aardaansluiting.

In het geval van installatie van ventil inde versie MV of MVB zonder bedieningaan boord, de klep vastmaken met eenschroef 2,2 x 9,5mm.

Om veiligheidsredenen is hetnoodzakelijk om de onderste sluitingente monteren in het geval van installatiesvan MV-apparaten zonder voetjes.De sluitingen voorkomen dat detechnische onderdelen en onderdelendie onder stroom staan van binneninmet de handen aangeraakt kunnenworden. Het niet monteren van dezesluitingen brengt de veiligheid vande personen ernstig in gevaar.

PRESCRIZIONIDI SICUREZZA SAFETY RULES

CONSIGNESDE SECURITE

SICHERHEITS-VORSCHRIFTEN

PRESCRIPCIONESDE SEGURIDAD

VEILIGHEIDS-VOORSCHRIFTEN

Page 8:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

8 8A

Per trasportare la macchina solle-varla da soli (per pesi inferiori a30 Kg) o con l’aiuto di un’altra per-sona.

Sollevarla lentamente, facendoattenzione che non cada.

Le ventole possono raggiungerela velocità di 1000 g/min.

Non inserire oggetti nell’elettro-ventilatore nè tantomeno le mani.

Non togliere le etichette di sicu-rezza all’interno dell’apparecchio.

In caso di illeggibilità richiedernela sostituzione.

When moving the appliance, lift itby yourself (for weights of under30 kg) or with the help of anotherperson.

Lift it slowly, taking care not todrop it.

Fan blades may reach speeds ofup to 1000 revs/min.

Never introduce objects or the handinto the fans.

Do not remove the safety labelsinside the appliance.

If you cannot read the labels, askfor replacements.

Pour transporter la machine, lasoulever tout seul (pour des poidsinférieurs à 30 kg) ou avec l’aided’une autre personne.

La soulever lentement, en faisantattention qu’elle ne tombe pas.

Les ventilateurs peuvent atteindrela vitesse de 1000 tr/mn.

Ne pas introduire d’objets dans leventilateur, et surtout pas les mains.

Ne pas retirer les étiquettes desécurité à l’intérieur de l’appareil.

Si les étiquettes sont illisibles, endemander d’autres exemplaires.

Für den Transport kann das Gerätalleine (für Gewicht unter 30 kg)oder zu zweit angehoben werden.

Langsam und vorsichtig anheben,damit es nicht herabfällt.

Die Laufräder können eine Drehzahlvon 1.000 U/min. erreichen.

Stecken Sie keine Gegenstände inden Ventilator, und greifen Sie erstrecht nicht mit den Händen hinein.

Die Sicherheitsetiketten im Geräte-innern dürfen nicht entfernt werden.

Falls Sie unleserlich sind, müssensie ersetzt werden.

Para desplazar la máquina bastauna persona (para pesos inferioresa los 30 Kg) o dos.

Levantarla despacio teniendo cui-dado en no soltarla.

Los ventiladores pueden alcanzaruna velocidad de 1000 r.p.m.

No introducir objetos en el ventila-dor ni tanto menos las manos.

No quitar las etiquetas de seguri-dad presentes dentro del aparato.

Si se estropean hasta quedar ile-gibles es preciso sustituirlas.

Voor het transport, heft u de machinealleen (voor gewichten kleiner dan30kg) of met de hulp van iemandanders.

Hef de machine traag op, zonderte laten vallen.

De propellers kunnen een snelheidvan 1000 t/min. halen.

Steek geen voorwerpen of handenin de elektronventilator.

Verwijder de veiligheidslabels aan debinnenkant van het apparaat niet.

Als de labels niet leesbaar zijn, laatu ze vervangen.

ATTENZIONE!NON TOGLIERE LA

PROTEZIONEDEL CIRCUITO STAMPATO

DELLA SCHEDAELETTRONICA

DAL SUPPORTO COMANDI.

IMPORTANT!DO NOT REMOVE

THE ELECTRICAL BOARDPRINTED CIRCUIT

GUARD FROMTHE CONTROL UNIT

MOUNTING.

ATTENTION!NE PAS RETIRERLA PROTECTION

DU CIRCUIT IMPRIMEDE LA CARTE

ELECTRONIQUEDU SUPPORT

DES COMMANDES.

ACHTUNG!DIE SCHUTZABDECKUNG

DER GEDRUCKTENSCHALTUNG DER PLATINE

DARF NICHTVON DER HALTERUNGDER STEUERUNGEN

GENOMMEN WERDEN.

ATENCIÓN!NO QUITAR LA PROTECCIÓN

DEL CIRCUITO IMPRESODA LA TARJETAELECTRÓNICADEL SOPORTEDEL CONTROL.

OPGELET!VERWIJDER

DE BEVEILIGING VAN HETGEDRUKTE CIRCUIT

VAN DE ELEKTRONISCHESCHAKELING NIET

AN DE BEDIENINGSBASIS.

IN CASO DI SOSTITUZIONEO PULIZIA DEL FILTRORICORDARSI SEMPRE

DI REINSERIRLOPRIMA

DELL’AVVIAMENTODELL’APPARECCHIATURA.

IF THE FILTERREQUIRES

REPLACING OR CLEANING,ALWAYS MAKE SUREIT IS REPOSITIONED

CORRECTLY BEFORESTARTING THE UNIT.

EN CASDE REMPLACEMENT OU

DE NETTOYAGE DU FILTRE,NE JAMAIS OUBLIER

DE LE REMETTREAVANT DE METTRE

L’APPAREIL EN MARCHE.

BEI ERSATZ ODERREINIGUNG DES FILTERSNICHT VERGESSEN, DEN

FILTER VOR DEMERNEUTEN EINSCHALTEN

DES GERÄTS WIEDEREINZUBAUEN.

EN CASO DE SUSTITUCIÓNO DE LIMPIEZA DEL FILTRO

ACORDARSE SIEMPREDE COLOCARLO DE NUEVO

EN SU SITIO ANTESDE PONER EN MARCHA

EL APARATO.

ALS U DE FILTERVERVANGT

OF SCHOONMAAKT,PLAATST U HEM STEEDS

TERUG VOORU HET APPARAAT

IN WERKING STELT.

In caso di sostituzione di compo-nenti richiedere sempre ricambioriginali.

In caso di installazioni in climi par-ticolarmente freddi, svuotare l’im-pianto idraulico in previsione dilunghi periodi di fermo macchina.

Nel caso di installazione con ser-randa di presa d’aria esterna fareattenzione al gelo invernale chepuò causare la rottura dei tubi del-la batteria.

Always use original spare parts.

In particularly cold climates, if theappliance is not to be used for longperiods, drain the hydraulic circuit.

If the installation is fitted with anexternal air intake damper, makesure the coil tubes are not damagedby temperatures below freezingpoint.

Si l’on doit remplacer des compo-sants, demander toujours des piècesde rechange originales.

En cas d’installation dans des climatsparticulièrement froids, vidangerl’installation hydraulique lorsqu’onprévoit de longues périodes d’arrêtde la machine.

En cas d’installation avec un voletde prise d’air extérieur, faire attentionau gel en hiver, qui peut provoquer larupture des tubes de la batterie.

Verlangen Sie immer Originaler-satzteile.

Bei Installation in einem besonderskalten Klima muss der Wasser-kreislauf entleert werden, wenn dasGerät für längere Zeit nicht benutztwird.

Achtung bei Installation mit Zuluft-klappe im Freien, durch winterlichenFrost können die Rohre der Batteriebeschädigt werden.

En caso de sustitución de compo-nentes, pedir siempre repuestosoriginales.

En caso de instalación en climasparticularmente fríos, vaciar lainstalación hidráulica si se prevénlargos plazos de parada de lamáquina.

En caso de instalación con tomade aire exterior tener cuidado conel hielo que puede causar la roturade los tubos de la batería.

Bij de vervanging van onderdelen,vraagt u steeds naar originelewisselstukken.

Voor een installatie in een bijzonderekoude omgeving, ledigt u dehydraulische installatie als u voorzietdat de machine gedurende eenlange periode niet zal werken.

Voor een installatie met een externeluchtklep, kijk uit voor wintervorstdie de buizen van de batterij kanbeschadigen.

Page 9:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

I dati fondamentali relativi al ventil-convettore e allo scambiatore dicalore sono i seguenti:

Ventilconvettoree scambiatore di calore:

• Temperatura massima del fluido termovettore: max 85°C

• Temperatura minima del fluido di raffreddamento: min 5°C

• Pressione di esercizio massima: 1000 kPa

• Tensione di alimentazione: 230V - 50Hz

• Consumo di energia elettrica: vedi targhetta dati tecnici

I dati tecnici delle valvole conazionatore termoelettrico sono iseguenti:

Valvole conazionatore termoelettrico:

• Pressione di esercizio: 1000 kPa

• Temperatura massima acqua di mandata: 100°C

• Temperatura ambiente massima: 50°C

• Tensione di alimentazione: 230V~50/60Hz

• Rating/protezione VA: 5 VA/IP 44

• Tempo di chiusura: 180 sec.

• Contenuto massimo di glicole nell’acqua: 50%

Altri dati tecnici

Tutti gli altri dati tecnici importanti(dimensioni, pesi, collegamenti, ru-morosità, ecc.) vengono forniti inaltre parti del presente Manuale,nella documentazione tecnica aparte o nella proposta tecnica.

The basic specification of the fancoil and heat exchanger is givenbelow:

Fan coiland heat exchanger:

• Maximum temperature of heat vector fluid: 85°C

• Minimum temperature of refrigerant fluid: 5°C

• Maximum working pressure: 1000 kPa

• Power supply voltage: 230V - 50Hz

• Electric energy consumption: see technical data label

The technical specification of thevalves with thermoelectric actuatoris given below:

Valves withthermoelectric actuator:

• Working pressure: 1000 kPa

• Maximum discharge temperature: 100°C

• Maximum ambient temperature: 50°C

• Power supply voltage: 230V~50/60Hz

• Rating/VA protection: 5 VA/IP 44

• Closing time: 180 sec.

• Maximum glycol content in water: 50%

Other technical data

All other important technical data(dimensions, weights, connections,noise emissions, etc.) are givenelsewhere in this User InformationManual, in the separate technicaldocumentation or in the technicalproposal.

Les caractéristiques fondamentalesdu ventilo-convecteur et de l’échan-geur de chaleur sont les suivantes:

Ventilo-convecteuret échangeur de chaleur:

• Température maximale du fluide caloporteur: 85°C maxi

• Température minimale du fluide de refroidissement: 5°C mini

• Pression de marche maximale: 1000 kPa

• Tension d’alimentation: 230V - 50Hz

• Consommation d’énergie électrique: voir plaquette données techniques

Les données techniques dessoupapes à actionneur thermo-électrique sont les suivantes:

Vannes àcommande thermoélectrique:

• Pression de marche: 1000 kPa

• Température de refoulement maximale: 100°C

• Température ambiante maximale: 50°C

• Tension d’alimentation: 230V~50/60Hz

• Degré de protection: 5 VA/IP 44

• Temps de fermeture: 180 sec.

• Contenu maximal de glycol dans l’eau: 50%

Autres données techniques

Toutes les autres caractéristiquestechniques importantes (dimen-sions, poids, raccordements, bruitetc.) sont indiquées dans d’autresparties de ce livret, dans la docu-mentation technique à part ou dansla proposition technique.

Die wesentlichen Daten des Klima-konvektors und der Wärmetauschersind die folgenden:

Klimakonvektorund Wärmetauscher:

• Max. Temperatur des Kältemediums: 85°C

• Min. Temperatur der Kühlflüssigkeit: 5°C

• Max. Betriebsdruck: 1000 kPa

• Versorgungsspannung: 230V - 50Hz

• Energieverbrauch: siehe Typenschild

Die technischen Daten der thermo-elektrischen Ventile sind wie folgt:

Ventile mitthermoelektrischer Steuerung:

• Betriebsdruck: 1000 kPa

• Max. Auslasstemperatur: 100°C

• Max. Raumtemperatur: 50°C

• Versorgungsspannung: 230V~50/60 Hz

• Rating/Sicherung VA: 5 VA/IP 44

• Verschlusszeit: 180 Sek.

• Max. Glykolanteil im Wasser: 50%

Weitere technische Daten

Alle anderen wichtigen technischenDaten (Abmessungen, Gewichte,Anschlüsse, Geräuschpegel, usw.)sind an anderen Stellen diesesHandbuchs, in der separaten tech-nischen Dokumentation oder in denAngebotsunterlagen enthalten.

Los datos fundamentales relativosal ventilador convector y al intercam-biador de calor son los siguientes:

Ventilador convectore intercambiador de calor:

• Temperatura máxima del fluido termovector: máx. 85°C

• Temperatura mínima del fluido de enfriamiento: mín. 5°C

• Máxima presión de ejercicio: 1000 kPa

• Tensiones de alimentación: 230V - 50Hz

• Consumo de energía eléctrica: ver placa de datos técnicos

Los datos técnicos de las válvulascon accionador termoeléctrico sonlos siguientes:

Válvulas conaccionador termoeléctrico:

• Presión de ejercicio: 1000 kPa

• Temperatura máxima del agua descargada: 100°C

• Temperatura ambiental máxima: 50°C

• Tensión de alimentación: 230V~50/60Hz

• Rating/protección VA: 5 VA/IP 44

• Tiempo de cierre: 180 seg.

• Contenido máximo de glicol en el agua: 50%

Otros datos técnicos

Todos los otros datos técncicos im-portantes (eida, pesos, conexiones,ruido, etc.) se dan en otras partesdel presente Manual, en la docu-mentación técnica.

De belangrijke gegevens met betrekking tot de ventilator-convector en de warmtewisselaar:

Ventilator-convectoren warmtewisselaar:

• Maximumtemperatuur Vloeistof Thermovector: max. 85°C

• Minimumtemperatuur koelvloeistof: min. 5°C

• Maximale bedrijfsdruk: 1000 kPa

• Voedingsspanning: 230V - 50Hz

• Elektrisch energieverbruik: zie plaatje met technische gegevens

De technische gegevens van dekleppen met thermo-elektrischeinschakeling:

Kleppen met thermo-elektrische inschakeling:

• Bedrijfsdruk: 1000 kPa

• Maximale watertemperatuur voor inlaat: 100°C

• Maximale omgevingstemperatuur: 50°C

• Voedingsspanning: 230V~50/60Hz

• Rating/VA-bescherming: 5 VA/IP 44

• Sluitingstijd: 180 sec.

• Maximaal glycolgehalte water: 50%

Andere technische gegevens

Alle andere belangrijke technischegegevens (afmetingen, gewichten,aansluitingen, lawaai, enz.) wordengeleverd in andere delen van deHandleiding, in de technischedocumentatie of door het technischpersoneel.

9 9A

LIMITI DI IMPIEGO OPERATING LIMITS LIMITES D’EMPLOI EINSATZGRENZEN LÍMITES DE USO GEBRUIKSLIMIETEN

SMALTIMENTO

Le parti di consumo e quelle sosti-tuite vanno smaltite nel rispetto del-la sicurezza e in conformità con lenorme di protezione ambientale.

WASTE DISPOSAL

Consumables and replaced partsshould be disposed of safely andin accordance with environmentalprotection legislation.

ÉLIMINATION ENTSORGUNG ELIMINACIÓN AFDANKING

Les consommables et les piècesremplacées doivent être éliminésen respectant les règles de sécu-rité et les normes de protection del’environnement.

Verbrauchsteile und ersetzte Teilemüssen vorschriftsmäßig entsorgtwerden.

Las partes de consumo y las quese sustituyen se eliminan respe-tando la seguridad y de acuerdocon las normas de protección delmedio ambiente.

De verbruiksonderdelen en vervangenonderdelen worden afgedankt metrespect voor de veiligheidsvoorschriftenen overeenkomstig de milieuwetgeving.

Page 10:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

1 2 3 4 5 6 7 8 933

0,16

40

0,18

49

0,23

57

0,26

61

0,27

88

0,39

103

0,47

130

0,58

176

0,78WA

Mod.230/1 50Hz

13

14

14

13

14

14

17

20

16

19

18

24

30

21

26

19

25

31

22

27

21

27

33

24

29

22

28

34

25

30

26

33

40

30

36

35

43

51

41

48

36

44

52

42

50

14

15

15

14

15

16

19

22

18

21

21

27

33

24

29

22

28

34

25

30

24

30

36

27

32

25

31

37

28

33

30

37

44

34

40

39

47

55

45

52

40

48

56

46

54

1 2 3 4 5 6 7 8 91 2 3 4 5 6 7 8 9

Unità imballata - Packed unitUnité emballée - Verpackung des Gerätes

Unidad embalada - Verpakte eenheid

33+13+2

44+1

Mod.

Ran

gh

iR

ow

sR

ang

sR

eih

enF

ilas

Ran

gen

Unità non imballata - Unpacked unitUnité seule - Unverpackung des Gerätes

Unidad sin embalar - Eenheid zonder verpakking

1 2 3 4 5 6 7 8 90,5

0,7

0,2

0,4

0,6

0,8

0,2

0,4

0,9

1,3

0,3

0,6

0,9

1,3

0,3

0,6

1,3

1,7

0,4

0,8

1,6

2,2

0,5

1,0

1,7

2,4

0,5

1,0

1,9

2,8

0,6

1,2

1,9

2,8

0,6

1,2

34

+1+2

Mod.R

ang

hi

Ro

ws

Ran

gs

Rei

hen

Fila

sR

ang

en

600

V

Z

Ø 1/2" F

M

37

O

N

T

Ø 15 ext.

B

H

230

Ø 1/2" F

P

R

S

321

T

Ø 15 ext.

H

B

230

7144

125

133

158 158

A

C

530

A

B

170

158 158

A

7144

125

133

C

530

630

A

B

170

100

100

MV

MO – MVB

ATTACCHI IDRAULICI - HYDRAULIC CONNECTIONS - WASSERANSCHLÜSSERACCORDS HYDRAULIQUES - CONEXIONES HIDRÁULICAS - HYDRAULISCHE AANSLUITINGEN

10 10A

CARATTERISTICHETECNICHE

TECHNICALCHARACTERISTIC

CARACTERISTIQUESTECHNIQUES

TECHNISCHEEIGENSCHAFTEN

CARACTERÍSTICASTÉCNICAS

TECHNISCHEKARAKTERISTIEKEN

• Batteria a 3 o 4 ranghi

• 3 or 4 row heat exchanger

• Batterie à 3 ou 4 rangs

• 3- oder 4-Reihige Batterie

• Batería con 3 o 4 filas

• Batterij met 3 of 4 rangen

• Batteria addizionale di riscaldamento (1 rango o 2 ranghi)

• 1 or 2 row additional heat exchanger

• Batterie additionnelle de chauffage (à 1 rang ou 2 rangs)

• Zusatzregister für Heizleistung (1- oder 2-Reihige)

• Batería adicional de calefacción (con 1 fila o 2 filas)

• Extra batterij voor verwarming (1 rij of 2 rijen)

DIMENSIONI (mm) - DIMENSIONS (mm) - DIMENSIONS (mm)DIMENSIONEN (mm) - DIMENSIÓN (mm) - AFMETINGEN (mm)

PESO (kg) - WEIGHT (kg) - POIDS (kg)GEWICHT (kg) - PESO (kg) - GEWICHT (kg)

CONTENUTO ACQUA (Litri) - WATER CONTENTS (litres) - CONTENANCE EAU (l)WASSERINHALT (Liter) - CONTENIDO AGUA (Litros) - WATERINHOUD (Liter)

ASSORBIMENTO MOTORE - MOTOR ABSORPTION - CONSOMMATION MOTEURLEISTUNGSAUFNAHME MOTOR - COMSUMO MOTOR - MOTORABSORPTIE

Piedini non inclusi (accessorio)Feet optional extra

Pieds non compris (en option)Füße nicht im Preis enthalten (Zubehör)

Pies de apoyo no incluidos (accesorio)Voeten niet inbegrepen (optioneel)

ABCHMNOPRSTVZ

670

225

354

205

145

260

460

185

105

475

55

260

720

770

225

454

205

145

260

460

185

105

475

55

260

820

985

225

669

205

145

260

460

185

105

475

55

260

1035

985

225

669

205

145

260

460

185

105

475

55

260

1035

1200

225

884

205

145

260

460

185

105

475

55

260

1250

1200

225

884

205

145

260

460

185

105

475

55

260

1250

1415

225

1099

205

145

260

460

185

105

475

55

260

1465

1415

255

1099

235

170

270

450

210

110

465

85

290

1465

1415

255

1099

235

170

270

450

210

110

465

85

290

1465

1 2 3 4 5 6 7 8 9Mod.

Page 11:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

1 2 3 4 5 6 7 8 933

0,16

40

0,18

49

0,23

57

0,26

61

0,27

88

0,39

103

0,47

130

0,58

176

0,78WA

Mod.230/1 50Hz

9

10

11

10

11

13

16

19

15

18

18

23

28

20

25

19

24

29

21

26

21

26

31

23

28

22

27

32

24

29

25

31

37

28

34

33

40

47

38

45

33

41

49

39

47

10

11

12

11

12

15

17

20

17

20

19

25

31

22

27

20

26

32

23

28

22

28

34

25

30

23

29

35

26

31

27

34

41

31

37

35

43

51

41

48

36

44

52

42

50

1 2 3 4 5 6 7 8 91 2 3 4 5 6 7 8 9

Unità imballata - Packed unitUnité emballée - Verpackung des Gerätes

Unidad embalada - Verpakte eenheid

33+13+2

44+1

Mod.

Ran

gh

iR

ow

sR

ang

sR

eih

enF

ilas

Ran

gen

Unità non imballata - Unpacked unitUnité seule - Unverpackung des Gerätes

Unidad sin embalar - Eenheid zonder verpakking

374

330

354

218

205

145

260

460

185

105

475

65

260

720

474

430

454

218

205

145

260

460

185

105

475

65

260

820

689

645

669

218

205

145

260

460

185

105

475

65

260

820

689

645

669

218

205

145

260

460

185

105

475

65

260

820

904

860

884

218

205

145

260

460

185

105

475

65

260

1035

904

860

884

218

205

145

260

460

185

105

475

65

260

1035

1119

1075

1099

218

205

145

260

460

185

105

475

65

260

1250

1119

1075

1099

248

235

170

270

450

210

110

465

95

290

1250

1119

1075

1099

248

235

170

270

450

210

110

465

95

290

1250

DEFGHMNOPRSUXY

1 2 3 4 5 6 7 8 9Mod.

1 2 3 4 5 6 7 8 934

+1+2

Mod.R

ang

hi

Ro

ws

Ran

gs

Rei

hen

Fila

sR

ang

en

0,5

0,7

0,2

0,4

0,6

0,8

0,2

0,4

0,9

1,3

0,3

0,6

0,9

1,3

0,3

0,6

1,3

1,7

0,4

0,8

1,6

2,2

0,5

1,0

1,7

2,4

0,5

1,0

1,9

2,8

0,6

1,2

1,9

2,8

0,6

1,2

Ø 1/2" F

M

37

O

N

U

Ø 15 ext.

G

H

230

Ø 1/2" F

P

R

S

321

U

Ø 15 ext.

H

G

230

133

125

4471

153

F150 10

17

D

12 12

GH

Ø 15 ext.230E

119

153

1711

9

7144

125

133

F10

D

E12 12

511

D22 22

29100

12 12

G

H

Ø 15 ext.

230

11 11A

IV – IOInstallazione Verticale - Vertical Installation

Installation Vertical - Vertikal InstalliertInstalación Vertical - Verticale Installatie

IV – IOInstallazione Orizzontale - Horizontal Installation

Installation Horizontal - Horizontal InstalliertInstalación Horizontal - Horizontale Installatie

ATTACCHI IDRAULICI - HYDRAULIC CONNECTIONS - WASSERANSCHLÜSSERACCORDS HYDRAULIQUES - CONEXIONES HIDRÁULICAS - HYDRAULISCHE AANSLUITINGEN

CARATTERISTICHETECNICHE

TECHNICALCHARACTERISTIC

CARACTERISTIQUESTECHNIQUES

TECHNISCHEEIGENSCHAFTEN

CARACTERÍSTICASTÉCNICAS

TECHNISCHEKARAKTERISTIEKEN

• Batteria a 3 o 4 ranghi

• 3 or 4 row heat exchanger

• Batterie à 3 ou 4 rangs

• 3- oder 4-Reihige Batterie

• Batería con 3 o 4 filas

• Batterij met 3 of 4 rangen

• Batteria addizionale di riscaldamento (1 rango o 2 ranghi)

• 1 or 2 row additional heat exchanger

• Batterie additionnelle de chauffage (à 1 rang ou 2 rangs)

• Zusatzregister für Heizleistung (1- oder 2-Reihige)

• Batería adicional de calefacción (con 1 fila o 2 filas)

• Extra batterij voor verwarming (1 rij of 2 rijen)

600

X

Y

DIMENSIONI (mm) - DIMENSIONS (mm) - DIMENSIONS (mm)DIMENSIONEN (mm) - DIMENSIÓN (mm) - AFMETINGEN (mm)

PESO (kg) - WEIGHT (kg) - POIDS (kg)GEWICHT (kg) - PESO (kg) - GEWICHT (kg)

CONTENUTO ACQUA (Litri) - WATER CONTENTS (litres) - CONTENANCE EAU (l)WASSERINHALT (Liter) - CONTENIDO AGUA (Litros) - WATERINHOUD (Liter)

ASSORBIMENTO MOTORE - MOTOR ABSORPTION - CONSOMMATION MOTEURLEISTUNGSAUFNAHME MOTOR - COMSUMO MOTOR - MOTORABSORPTIE

Sezione di mandata (E x 119)Outlet section (E x 119)

Section de soufflage (E x 119)Ausblaseinheit (E x 119)

Sección de impulsión (E x 119)Afmetingen uitlaat (E x 119)

*

Vaschetta raccolta condensa (optional) - Condensate tray (optional)Kondensatwanne (optional) - Bac à condensats (option)Bandeja de recogida condensacion (opción) - Opvangbak condenswater (optioneel)

Page 12:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

12 12A

INSTALLAZIONEMECCANICA

Installare l’apparecchio in una po-sizione tale da non compromet-tere l’aspirazione dell’aria (vediillustrazione).

Nell’installazione dei ventilconvet-tori a soffitto si consiglia di tenerben presente il possibile problemadi stratificazione dell’aria; ricordia-mo inoltre che le griglie di manda-ta devono essere posizionate inmodo che la direzione del flussod’aria sia verso il basso.

Fissare la struttura del ventil-con-vettore; MV-MVB-IV alla parete,MO-IO al soffitto.In corrispondenza delle asole rica-vate sulla stessa posizionare 4tasselli (viti consigliate M8).

Per l’installazione contro vetratao in qualsiasi altra posizione dovenon esista una parete, è possibilerichiedere staffe per il fissaggio apavimento.

Versioni MV-MVB-MO; coprire lastruttura con il mobile e fissarloalla struttura con le viti fornite acorredo.Inserire il filtro aria nelle sue guidee bloccare il profilo portafiltro.

Versioni MV senza piedini - chiu-sura inferiore - (pannello) acces-sorio indispensabile per impedireil raggiungimento delle parti internedei vani tecnici.

MECHANICALINSTALLATION

When positioning the appliance,make sure the air intakes are freefrom obstructions (see illustration).

When installing the fan coils on theceiling, keep in mind the possibleproblem of stratification of the air; it should also be remembered thatthe outlet grills must be positionedso that the air flows downwards.

Fix the frame of the fan coil to thewall (models MV, MVB and IV) orceiling (models MO, IO).Position the four anchors (M8 screwsare recommended) in correspondenceto the four slits in the frame.

To install against a glazed surfaceor in other position where there isno wall, brackets can be used tofix the unit to the floor.

In versions MV, MVB and MO, fitthe casing over the frame and fixusing the screws supplied.Insert the air filter into the guidesand lock the filter holder strip inplace.

Version MV without feet - bottompanel - an indispensable accessoryto prevent access to parts insidethe technical compartments.

INSTALLATIONMECANIQUE

MECHANISCHEINSTALLATION

INSTALACIÓNMECÁNICA

MECHANISCHEINSTALLATIE

Installer l’appareil dans une positionn’empêchant pas l’aspiration de l’air(cf. illustration).

Lorsqu’on installe des ventilo-con-vecteurs au plafond il est conseilléde prendre en compte le problèmepossible de stratification de l’air;nous rappelons en outre que lesgrilles de soufflage doivent êtreplacées de façon à ce que le fluxd’air soit dirigé vers le bas.

Fixer la structure du ventilo-con-vecteur; celle des MV-MVB-IV à laparoi et celle des MO-IO au plafond.Positionner, au niveau des trousoblongs pratiqués dans la structure,quatre chevilles à expansion (visconseillées M8).

Pour l’installation contre une baievitrée ou dans une quelconqueautre position où il existe pas deparoi, on peut demander des pattespour la fixation au sol.

Versions MV-MVB-MO: couvrir lastructure avec la carrosserie enfixant cette dernière à la structure,avec les vis fournies de série.Insérer le filtre à air dans ses guideset bloquer le profilé porte-filtre.

Version MV sans pieds - fennetureinférieure - accessoire indispensablepour empêcher d’atteindre les partiesintérieures des compartiments tech-niques.

Das Gerät muss so installiert werden,dass die Luftansaugung nicht beein-trächtigt wird (siehe Darstellung).

Bei der Deckeninstallation vonKlimakonvektoren sollte unbedingtdas potentielle Problem der Luft-stratifikation berücksichtigt werden;außerdem erinnern wir daran, dassdie Ausblasgitter so positioniertsein müssen, dass der Luftstromnach unten gerichtet ist.

Die Struktur des GebläsekonvektorsMV-MVB-IV an der Wand, bzw.MO-IO an der Decke befestigen.An den Schlitzen 4 Dübel anbringen(empfohlene Schrauben M8).

Für die Installation gegen eineverglaste Fläche oder in einersonstigen Stellung, in der keineWand vorhanden ist, können Bügelfür die Befestigung am Bodenangefordert werden.

Ausführungen MV-MVB-MO: dieGerätestruktur mit dem Gehäuseabdecken. Das Gehäuse mit denmitgelieferten Schrauben an derStruktur befestigen.Den Luftfilter in seine Führungeneinschieben und das Filter-Halteprofilbefestigen.

Version MV ohne Füße - mit unteremVerschluss - ein unerlässlichesZubehör, um den Zugriff auf dieinneren Komponenten zu verhindern.

Instalar el aparato en una posicióntal que no se impida la aspiracióndel aire (ver dibujo).

En la instalación de los ventilado-res convectores de techo se reco-mienda tener muy presente el po-sible problema de estratificacióndel aire; además recordamos quelas rejillas de impulsión tienen quecolocarse de modo que la direccióndel flujo de aire sea hacia abajo.

Asegurar la estructura del fan coil;MV-MVB-IV a la pared, MO-IO altecho.En correspondencia con las ranurasque lleva colocar 4 tacos de expan-sión (tornillos aconsejados M8).

Para la instalación contra crista-leras o en cualquier otra posicióndonde no haya una pared, es po-sible solicitar unos estribos parala sujeción al suelo.

Variantes MV-MVB-MO; cubrir laestructura con el mueble y asegu-rarlo a la estructura con los tornillosincluidos en el suministro.Introducir el filtro del aire en susguías correspondientes y bloquearel perfil porta-filtro.

Versiones MV sin pies - cierreinferior - accesorio indispensablepara impedir alcanzar las partesinternas de las aperturas técnicas.

Installeer het apparaat in een positiedie de luchtaanvoer niet in hetgedrang brengt (zie illustratie).

Bij de installatie van plafond-ventilator-convectors is hetaangeraden rekening te houden methet probleem van luchtstratificatie;wij herinneren er u tevens aan datde luchtroosters op die maniergeplaatst moeten worden, dat deluchtstroom naar onder is gericht.

Bevestig de structuur van de ventilator-convector; MV-MVB-IV aan de wand,MO-IO aan het plafond.Steek 4 pluggen in de gatenaangebracht in de structuur(aanbevolen schroeven M8).

Voor een installatie aan eenglaswand ofin een andere positiewaar geen wand aanwezig is, zijnkrammen beschikbaar voor debevestiging aan de vloer.

Versies MV-MVB-MO; bedek destructuur met de behuizing enbevestig deze aan de structuur metbehulp van de bijgeleverde schroeven.Schuif de luchtfilter in zijn geleidersen blokkeer het profiel van defilterhouder.

Versie MV zonder voetjes - onderstesluiting - (paneel) onmisbaaraccessoire om het bereiken vaninterne delen in de technischeruimtes te voorkomen.

ATTENZIONE!INSTALLARE

L’APPARECCHIO SEMPREIN LEGGERA PENDENZA

8mm VERSO IL LATODI SCARICO CONDENSA.

WARNING!ALWAYS INSTALL

THE UNITWITH A SLOPE

OF ABOUT 8mm TOWARDSTHE CONDENSATE

DRAIN SIDE.

ATTENTION!INSTALLER

TOUJOURS L’APPAREILAVEC UNE LEGERE PENTE

DE 8mm VERSLE COTE D’EVACUATION

DES CONDENSATS.

ACHTUNG!DAS GERÄT MUSS IMMER

IN LEICHTER (8 mm)NEIGUNG IN RICHTUNGKONDENSATAUSLASSINSTALLIERT WERDEN.

ATENCIÓN!INSTALAR EL APARATO

SIEMPRE CONUNA LIGERA PENDIENTEDE 8mm HACIA EL LADO

DE DESCARGADEL CONDENSADO.

OPGELET!INSTALLEER HET APPARAAT

STEEDS MET EEN LICHTEHELLING VAN 8 mm NAAR

DE ZIJDE WAARHET CONDENSATIEVOCHT

WORDT AFGEVOERD.

È possibile installare l’apparecchiocon qualsiasi altro mezzo ritenutoidoneo dall’installatore; purchèconforme alle norme vigenti.

The unit can be installed using anyother method considered appropriateby the installer, providing it is inaccordance with current legislation.

L’installeur pourra installer l’appareilavec n’importe quel autre moyenjugé approprié, à condition qu’il soitconforme aux normes en vigueur.

Das Gerät kann mit jedem anderen,vom Installateur für zweckmäßigerachteten Mittel installiert werden,jedoch immer unter der Voraussetzung,dass die Installation den einschlägigenBestimmungen entspricht.

Es posible instalar el aparato concualquier otro medio consideradoadecuado por el instalador; siem-pre y cuando cumpla con las nor-mas vigentes.

Het is mogelijk het apparaat teinstalleren met om het even welkinstrument dat door de monteurgeschikt wordt geacht, mits nalevingvan de van kracht zijnde normen.

Page 13:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

13 13A

COLLEGAMENTOIDRAULICO

1 - Svitare le 4 viti di fissaggio (2 per lato) della batteria alla strut- tura e togliere la batteria.

2 - Sconnettere i cavi di collega- mento (prendendo nota dei co- lori dei cavi). Svitare le viti di fissaggio, e rimuovere la mor- settiera.

3 - Inserire la batteria fissandola con le 4 viti.

4 - Fissare il quadro comandi e la relativa morsettiera, nel lato opposto a quello degli attacchi.

5 - Per ripristinare i collegamenti elettrici osservare le note pre- se, aiutandosi con gli schemi elettrici.

HYDRAULICCONNECTIONS

1 - Undo the four screws (two per side) fixing the coil to the frame and remove the coil.

2 - Disconnect the wires (taking note of the colour). Undo the screws fixing the terminal board and remove it.

3 - Replace the coil, fixing it with the four screws.

4 - Fix the control unit and terminal board on the opposite side to the connections.

5 - Reconnect the electrical wires, following the notes made previously and referring to the electrical wiring diagram.

RACCORDEMENTHYDRAULIQUE WASSERANSCHLUSS

ENLACEHIDRÁULICO

HYDRAULISCHEAANSLUITING

1 - Dévisser les 4 vis (2 par côté) fixant la batterie à la structure et retirer la batterie.

2 - Déconnecter les câbles de raccordement (en prenant note des couleurs des câbles). Dévisser les vis de fixation et retirer le bornier.

3 - Insérer la batterie à la fixant avec les 4 vis.

4 - Fixer le panneau de commande et le bornier correspondant sur le côté opposé à celui des raccords.

5 - Pour refaire les branchements électriques, consulter les notes ayant été prises et les schémas électriques.

1 - Die 4 Schrauben (2 pro Seite), mit denen die Batterie an der Struktur befestigt ist, lösen und die Batterie abnehmen.

2 - Die Anschlusskabel abhängen (dabei die Farben der Kabel notieren). Die Befestigungs- schrauben lösen und das Klemmenbrett abnehmen.

3 - Die Batterie einsetzen und mit den 4 Schrauben befestigen.

4 - Das Bedienfeld und das entsprechende Klemmenbrett an der gegenüberliegenden Seite der Anschlüsse befestigen.

5 - Beim Wiederherstellen der elektrischen Anschlüsse die zuvor notierten Farben beachten und die elektrischen Schalt- pläne zu Hilfe nehmen.

1 - Desenroscar los 4 tornillos de fijación (2 por lado) de la bate- ría a la estructura y retirar la batería.

2 - Desconectar los cables de enlace (tomando nota de los colores de los cables). Desen- roscar los tornillos de fijación y retirar la borna de conexión.

3 - Introducir la batería asegurán- dola con los 4 tornillos.

4 - Asegurar el tablero de mandos y la borna de conexión corre- spondiente en el lado opuesto al de las conexiones.

5 - Para restablecer los enlaces eléctricos ajustarse a cuanto apuntado previamente y seguir los esquemas.

1 - Draai de 4 schroeven los (2 aan weerszijden) die de batterij aan de structuur bevestigen, en verwijder de batterij.

2 - Koppel de aansluitingskabels los (let op de kleur van de kabels). Draai de bevestigings- schroeven los en verwijder het klemmenbord.

3 - Bevestig de batterij met de 4 schroeven.

4 - Bevestig het bedieningspaneel en het relatieve klemmenbord aan de zijde tegenover de aansluitingen.

5 - Om de elektrische aansluitingen te herstellen, raadpleeg de nota’s en de elektrische schema’s.

PRESSIONE MASSIMADI ESERCIZIO: 1000 kPa.

MAXIMUM WORKINGPRESSURE: 1000 kPa.

PRESSION MAXIDE SERVICE: 1000 kPa.

MAXIMALEBETRIEBSDRUCK: 1000 kPa.

PRESIÓN MÁXIMADE OPERACIÓN: 1000 kPa.

MAXIMALEBEDRIJFSDRUK: 1000 kPa.

USARE SEMPRECHIAVE E CONTROCHIAVE

PER L’ALLACCIAMENTODELLA BATTERIAALLE TUBAZIONI.

ALWAYS USETWO SPANNERS

TO CONNECTTHE HEAT EXCHANGER

TO THE PIPES.

UTILISER TOUJOURSUNE CLE

ET UNE CONTRE-CLEPOUR LE RACCORDEMENT

DE LA BATTERIEAUX TUYAUTERIES.

FÜR DEN ANSCHLUSSDER BATTERIE

AN DIE ROHRLEITUNGENIMMER SCHLÜSSEL

UND GEGENSCHLÜSSELBENUTZEN.

USAR SIEMPRELLAVE Y CONTRALLAVE

PARA ENLAZARLA BATERÍA

A LAS TUBERÍAS.

GEBRUIKSTEEDS SLEUTELS

EN TEGENSLEUTELSOM DE BATTERIJTE VERBINDEN

MET DE BUIZEN.

PREVEDERE SEMPREUNA VALVOLA

DI INTERCETTAZIONEDEL FLUSSO IDRAULICO.

ALWAYSFIT A GATE VALVE

IN THE WATER CIRCUIT.

PREVOIR TOUJOURSUNE VANNE D’ARRET

DU FLUX HYDRAULIQUE.

IMMER EIN SPERRVENTILDES WASSERFLUSSES

INSTALLIEREN.

PREVER SIEMPREUNA VÁLVULA

DE ABRE-CIERREDEL FLUJO HIDRÁULICO

VOORZIE STEEDS EENRETOURKLEP.

NEL CASOSI DEBBA INVERTIRE

IL LATO ATTACCHIPROCEDERE

SECONDO LE SEGUENTIILLUSTRAZIONI:

TO REVERSETHE CONNECTIONS SIDE,PROCEED AS FOLLOWS:

DANS LE CAS OU L’ONDEVRAIT INVERSER

LE COTE DES RACCORDS,PROCEDER

COMME INDIQUESUR LES ILLUSTRATIONS

QUI SUIVENT.

FALLS DIE ANSCHLÜSSEAUF DIE ANDERE

SEITE VERLEGT WERDENMÜSSEN,

WIE NACHSTEHENDBESCHRIEBEN VORGEHEN.

SI SE DEBE INVERTIREL LADO

DE LAS CONEXIONESPROCEDER SEGÚN

LAS ILUSTRACIONESSIGUIENTES.

INDIEN DE AANSLUITINGENVAN ZIJDE MOETEN

WORDEN VERANDERD,GAAT U TE WERK ZOALS

AANGEDUIDIN DE VOLGENDEILLUSTRATIES:

Page 14:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

14 14A

Nel caso l’apparecchio sia fornitodi valvola collegare i tubi di colle-gamento alla valvola stessa.

Se l’apparecchio è usato per raf-freddare, per evitare gocciolamentodi condensa, isolare le tubazioni ela valvola.

Nei periodi estivi e per lunghi pe-riodi di tempo con il ventilatore di-sinserito, per evitare formazioni dicondensa all’esterno dell’apparec-chio, si consiglia di intercettarel’alimentazione della batteria.

Nel caso venga richiesta la va-schetta supplementare, raccoltacondensa, questa va fissata allastruttura dal lato attacchi e il tubodi scarico condensa va collegatoa quest’ultima.

Nelle versioni MV - MVB - MO èpossibile invertire il flusso d’ariagirando la griglia, come da illustra-zione.

If the unit is fitted with a valve,connect the connection pipes tothe valve.

If the unit is used for cooling,insulate the pipes and valve toavoid drops of condensate forming.

During the summer and when thefan is inactive for long periods, youare recommended to shut off thewater supply to the coil to avoidcondensation forming on the outsideof the unit.

If a supplementary condensatedrain pan is used, this should befixed to the connections side ofthe frame and the condensatedrain pipe should be fastened tothe latter.

In the MV, MVB and MO versions,the air flow can be reversed byrotating the grill as illustrated.

Si l’appareil est équipé d’une vanne,brancher les tuyauteries de raccorde-ment à cette même vanne.

Si on utilise l’appareil pour rafraîchir,isoler les tuyauteries et la vanneafin d’éviter des égouttements decondensats.

Pendant l’été et lorsque le ventilateurreste longtemps débranché, il estconseillé d’isoler l’alimentation de labatterie afin d’éviter les formationsde condensation à l’extérieur del’appareil.

Si le bac supplémentaire (de récupé-ration des condensats) est demandé,il doit être fixé à la structure du côtédes raccords et le tuyau d’évacuationdes condensats doit être raccordéà ce bac.

Dans les versions MV - MVB - MO,on peut inverser le flux d’air entournant la grille (cf. illustration).

Falls das Gerät mit Ventil ausgestattetist, die Anschlussleitungen mit demVentil verbinden.

Wenn das Gerät zum Kühlen benutztwird, müssen die Rohrleitungen und das Ventil isoliert werden, umein Heraustropfen von Kondens-wasser zu vermeiden.

Im Sommer und wenn der Ventilatorfür längere Zeit nicht benutzt wird,empfiehlt sich, die Zuleitung zurBatterie zu sperren, damit sichaußen am Gerät kein Kondens-wasser bildet.

Falls eine zusätzliche Kondensat-wanne verlangt wird, wird diese aufder Anschlussseite an der Strukturbefestigt und die Kondensatablauf-leitung wird daran angeschlossen.

Bei den Ausführungen MV - MVB -MO kann der Luftstrom umgekehrtwerden, indem das Ausblasgitterwie auf der Abbildung dargestelltumgedreht wird.

Si el aparato lleva válvula, conectarlos tubos de enlace con la propiaválvula.

Si se usa el aparato para enfriar,para evitar goteos de condensadoes preciso aislar las tuberías y laválvula.

En las temporadas veraniegas ycuando se prevea dejar apagadoel ventilador por mucho tiempo,para evitar formaciones de con-densado al exterior del aparato seaconseja interceptar el agua dealimentación de la batería.

En el caso de que se requiera lapileta suplementaria, de recogidadel condensado, es preciso fijarlaa la estructura por el lado conexionesy el tubo de descarga del conden-sado debe conectarse a esta última.

En las variantes MV - MVB - MOes posible invertir el flujo del airegirado la rejilla, como mostrado enel dibujo.

Indien het apparaat uitgerust is meteen klep, sluit u de buizen rechtstreeksaan op de klep.

Als het apparaat wordt gebruikt omaf te koelen, en om het druppelenvan condenswater te voorkomen,isoleert u de buizen en de klep.

In de zomermaanden en indiende ventilator lange tijd niet wordtgebruikt, is het raadzaam de voedingvan de batterij te onderbreken, omde vorming van condensatievochtaan de buitenkant van het apparaatte voorkomen.

Als voor het opvangen van hetcondensatievocht het gebruik vaneen bijkomende opvangbak wordtgevraagd, wordt deze bevestigdaan de structuur, aan de zijde vande aansluitingen; de afvoerbuiswordt aangesloten aan deze laatste.

Voor de versies MV - MVB - MO kande luchtstroom worden omgedraaiddoor het roostertje te draaien zoalsbeschreven in de illustratie.

ATTENZIONE!È CONSIGLIATO SIFONARE

LO SCARICODELLA CONDENSA,

INSTALLAREIL TUBO

DI SCARICO CONDENSACON UNA PENDENZA

DI ALMENO 3 cm/metro.

IMPORTANT!YOU ARE RECOMMENDED

TO FIT A SIPHONON THE CONDENSATE

DRAIN. INSTALLA CONDENSATE

DRAIN PIPEWITH A SLOPE OF

AT LEAST 3 cm/metre.

ATTENTION!IL EST CONSEILLE DE

SIPHONER L’EVACUATIONDES CONDENSATS

ET D’INSTALLER LE TUYAUD’EVACUATION

DES CONDENSATSAVEC UNE PENTE

D’AU MOINS 3 cm/m.

ACHTUNG!DER KONDENSATAUSLASSSOLLTE MÖGLICHST MIT

EINEM SIPHON VERSEHEN,UND DIE KONDENSAT-

ABLAUFLEITUNGMIT EINER NEIGUNG VONMINDESTENS 3 cm/MeterINSTALLIERT WERDEN.

ATENCIÓN!SE ACONSEJA COLOCAR

UN SIFÓN EN LA DESCARGADEL CONDENSADO,INSTALAR EL TUBO

DE DESCARGADEL CONDENSADO

CON UNA PENDIENTE DEPOR LO MENOS 3 cm/metro.

OPGELET!HET IS RAADZAAM

DE AFVOERBUIS VAN HETCONDENSATIEVOCHT

TE HEVELEN,EN DE AFVOERBUIS

TE INSTALLEREN MET EENHELLING VAN MINSTENS

3 cm/meter.

ATTENZIONE!NEL CASO CI SIA

UNA SECONDA BATTERIADI SCAMBIO TERMICO

PROCEDERECOME ILLUSTRATO

IN PRECEDENZASE SI DEVE CAMBIARE

IL LATO ATTACCHI.

IMPORTANT!IF A SECOND

HEAT EXCHANGER COILIS FITTED, TO CHANGE

THE CONNECTIONS SIDE,PROCEED AS

DESCRIBED PREVIOUSLY.

ATTENTION!DANS LE CAS OU IL Y

AURAIT UNE DEUXIEMEBATTERIE D’ECHANGE

THERMIQUE,PROCEDER COMME

INDIQUE PRECEDEMMENTSI ON DOIT CHANGER

LE COTE DES RACCORDS.

ACHTUNG!FALLS EINE ZWEITEWÄRMETAUSCHER-

BATTERIEVORHANDEN IST, GENAUSOWIE OBEN BESCHRIEBEN

VORGEHEN, WENN DIEANSCHLUSSSEITE

VERLEGTWERDEN MUSS.

ATENCIÓN!SI HAY UNA SEGUNDA

BATERÍADE INTERCAMBIO TÉRMICO,

PROCEDERCOMO MOSTRADOANTERIORMENTE

SI ES PRECISO CAMBIAREL LADO

DE LAS CONEXIONES.

OPGELET!INDIEN ER EEN TWEEDE

BATTERIJ VOOR DE WARM-TEWISSELING IS, GAAT U TEWERK ZOALS BESCHREVEN

IN BOVENSTAANDEILLUSTRATIE ALS DE ZIJDEN

VAN DE AANSLUITINGENMOETEN WORDEN

OMGEWISSELD.

Page 15:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

40

30

20

1098765

4

3

2

1100 200 300 400 600 800 1000 2000 3000 4000

Kvs 2 Kvs 2,5

Kvs 1,640

30

20

1098765

4

3

2

1100 200 300 400 600 800 1000 2000 3000 4000

Kvs 2

Kvs 1,6

Codice - Code - Art. Nr. - Código

MontataFitted

MontéeMontiertMontada

Gemonteerd

Non montataNot fittedÀ monter

Nicht MontiertNo montada

Niet gemonteerd

9066561W/H

9060471W/H

9060471W/H

9066560W/H

9060474W/H

9060474W/H

15

15

15

DN1/2” F

1/2” F

1/2” F

(Ø)2

2

2

Kvs

Dimensioni (mm)Dimensions (mm)Dimensions (mm)

Dimensionen (mm)Dimensión (mm)Afmetingen (mm)

ValvolaValveVanne

WasserventilVálvula

Klep

15

20

20

DN1/2”

3/4”

3/4”

(Ø)1,6

2,5

2,5

Kvs25

25

50

85

85

120

190

190

185

290

290

290

105

105

105

A B C D E1 ÷ 56 – 78 – 9

Mod.

DetentoreManual stop valve

DétenteurReduzierventil

DetentorHouders

Codice - Code - Art. Nr. - Código

MontataFitted

MontéeMontiertMontada

Gemonteerd

Non montataNot fittedÀ monter

Nicht MontiertNo montada

Niet gemonteerd

9060472W/H

9060472W/H

9060475W/H

9060475W/H

15

15

DN1/2” F

1/2” F

(Ø)2

2

Kvs

Dimensioni (mm)Dimensions (mm)Dimensions (mm)

Dimensionen (mm)Dimensión (mm)Afmetingen (mm)

ValvolaValveVanne

WasserventilVálvula

Klep

15

15

DN1/2”

1/2”

(Ø)1,6

1,6

Kvs120

135

195

200

240

235

340

330

A B C D1 – 78 – 9

Mod.

DetentoreManual stop valve

DétenteurReduzierventil

DetentorHouders

Valvola a 3 vie per batteria principale VBPValvola acqua a tre vie ON-OFF 230 V e kit di montaggio con detentore a regolazione micrometrica (accessorio optional).

VBP main battery 3 way valveControl valve kit: 3 way valve, ON-OFF, with electric motor and mounting kit with regulating check valve (optional).

Vanne pour batterie principale VBPVanne 3 voies (ON-OFF), 230V et kit de montage avec tés de réglage micrométrique (option).

3-Wege-Wasserventil für Hauptregister VBP3-Wege-Wasserventil ON-OFF 230 V mit elektrischem Motor und Montage KIT mit Reglerventil (optional).

Válvula para batería principal VBPVálvula agua de tres vías ON-OFF, con actuador eléctrico y kit de montaje (opción).

Klep voor hoofdbatterij VBPDriewegswaterklep ON-OFF, met elektrische bediening en montagekit (optioneel accessoire).

15 15A

Valvola a 3 vie per batteria addizionale VBAValvola acqua a tre vie ON-OFF 230 V e kit di montaggio con detentore a regolazione micrometrica (accessorio optional).

VBA auxiliary battery 3 way valveControl valve kit: 3 way valve, ON-OFF, with electric motor and mounting kit with regulating check valve (optional).

Vanne pour batterie additionnelle VBAVanne 3 voies (ON-OFF), 230V et kit de montage avec tés de réglage micrométrique (option).

3-Wege-Wasserventil für Zusatzregister VBA3-Wege-Wasserventil ON-OFF 230 V mit elektrischem Motor und Montage KIT mit Reglerventil (optional).

Válvula para batería adicional VBAVálvula agua de tres vías ON-OFF, con actuador eléctrico y kit de montaje (opción).

Klep voor hulp batterij VBADriewegswaterklep ON-OFF, met elektrische bediening en montagekit (optioneel accessoire).

Dp - kPa

Portata acqua (l/h) - Water flow (l/h)Débit d’eau (l/h) - Wasserdurchflussmenge (l/h)Caudal de agua (l/h) - Waterdebiet (l/h)

Dp - kPa

Portata acqua (l/h) - Water flow (l/h)Débit d’eau (l/h) - Wasserdurchflussmenge (l/h)Caudal de agua (l/h) - Waterdebiet (l/h)

TERRA - EARTH - SOLERDE - TIERRA - AARDE

TERRA - EARTH - SOLERDE - TIERRA - AARDE

Page 16:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

Dimensioni (mm)Dimensions (mm)Dimensions (mm)

Dimensionen (mm)Dimensión (mm)Afmetingen (mm)

Principale - Main - PrincipaleHaupt - Principal - Hoofd

Addizionale - Additional - AdditionnelleZusatz - Adicional - Hulp

15 1/2” 1,7 9060476W 9060478W

15

20

20

1/2”

3/4”

3/4”

1,7

2,8

2,8

9060476W

9060477W

9060477W

9060478W

9060479W

9060479W

MontataFitted

MontéeMontiertMontada

Gemonteerd

Non montataNot fittedÀ monter

Nicht MontiertNo montada

Niet gemonteerd

ValvolaValveVanne

WasserventilVálvula

Klep

Cod. - Code - Art. Nr. - CódigoDN (Ø) Kvs

MontataFitted

MontéeMontiertMontada

Gemonteerd

Non montataNot fittedÀ monter

Nicht MontiertNo montada

Niet gemonteerd

ValvolaValveVanne

WasserventilVálvula

Klep

456

456

440

149

150

176

180

181

175

386

438

422

186

186

210

H Cod. - Code - Art. Nr. - CódigoDN (Ø) KvsA C D E1 ÷ 56 – 78 – 9

Mod.

Dimensioni (mm)Dimensions (mm)Dimensions (mm)

Dimensionen (mm)Dimensión (mm)Afmetingen (mm)

Principale - Main - PrincipaleHaupt - Principal - Hoofd

Addiz. - Additional - AdditionnelleZusatz - Adicional - Hulp

B1 B2A1 A2C

9066571W/H

9060484W/H

9060484W/H

9066570W/H

9060481W/H

9060481W/H

Cod. - Code - Art. Nr. - Código

15

20

20

1/2”

3/4”

3/4”

1,6

2,5

2,5

DN (Ø) Kvs

15 1/2” 1,6 9060483W/H 9060480W/H

Cod. - Code - Art. Nr. - CódigoDN (Ø) Kvs

ValvolaValveVanne

WasserventilVálvula

Klep

MontataFitted

MontéeMontiertMontada

Gemonteerd

Non montataNot fittedÀ monter

Nicht MontiertNo montada

Niet gemonteerd

MontataFitted

MontéeMontiertMontada

Gemonteerd

Non montataNot fittedÀ monter

Nicht MontiertNo montada

Niet gemonteerd

ValvolaValveVanne

WasserventilVálvula

Klep

185

185

210

330

330

327

152

152

177

270

268

270

116

124

124

** *1 ÷ 56 – 78 – 9

Mod.

Kvs 2,5

Kvs 1,640

30

20

1098765

4

3

2

1100 200 300 400 600 800 1000 2000 3000 4000

Kvs 1,7

Kvs 2,840

30

20

1098765

4

3

2

1100 200 300 400 600 800 1000 2000 3000 4000

16 16A

Portata acqua (l/h) - Water flow (l/h)Débit d’eau (l/h) - Wasserdurchflussmenge (l/h)Caudal de agua (l/h) - Waterdebiet (l/h)

Portata acqua (l/h) - Water flow (l/h)Débit d’eau (l/h) - Wasserdurchflussmenge (l/h)Caudal de agua (l/h) - Waterdebiet (l/h)

TERRA - EARTH - SOLERDE - TIERRA - AARDE

Valvola a 3 vie semplificata per batteria principale e addizionale VS (solo per unità IV - IO)Valvola acqua a tre vie ON-OFF 230 V e kit di montaggio senza detentore a regolazione micrometrica. Valvola con battuta piana (accessorio optional).

VS simplified valve kit for 3 way valve (IV - IO model only)3 way valve, (ON-OFF) with electric motor and mounting kit. Valve with flat connection without micrometric lockshield valve (optional).

Vanne sans tés de réglage pour batterie principale ou additionnelle VS (seulement pour versions IV - IO)Vanne 3 voies (ON-OFF), 230V et kit de montage. Vannes avec raccordement à joint plat (option).

3-Wege-Wasserventil ohne Absperrungen VS (nur für Geräte IV - IO)3-Wege-Wasserventil ON-OFF 230 V und Montage-Kit. Ventil mit waagrechten Anschlüssen (optional).

Válvula de tres vías simplificada VS (solo para modelos IV - IO)Válvula agua de tres vías ON-OFF, 230 V y kit de montaje. Válvula con asiento plano (opción).

Simpele drievoudige klep 3 voor hoofdbatterij en extra batterij VS (alleen voor unit IV - IO)Driewegswaterklep ON-OFF 230 V en montagekit. Klep met vlakke verbinding (optioneel accessoire).

Valvola a 2 vie per batteria principale e addizionale V2Valvola a 2 vie ON-OFF 230 V (accessorio optional).

V2 2 way valve for main and additional coilControl valve kit: 2 way valve, ON-OFF, with electric motor and mounting kit (optional).

Vanne pour batterie principale et batterie additionnelle V2Vanne 2 voies (ON-OFF), avec servomoteur et kit de montage (option).

2-Wege-Wasserventil für Hauptregister und für Zusatzregister V22-Wege-Wasserventil ON-OFF 230 V mit elektrischem Motor und Montage KIT (optional).

Válvula para batería principal y adicional V2Válvula eléctrica de dos vías ON-OFF, con actuador eléctrico y kit de montaje (opción).

Tweewegshoofdklep voor hoofdbatterij en extra batterij V2Tweewegsklep ON-OFF 230 V (optioneel accessoire).

Dp - kPa Dp - kPa

Page 17:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

17 17A

COLLEGAMENTIELETTRICI

Prescrizioni generali

• Prima di installare il ventilcon- vettore verificare che la tensione nominale di alimentazione sia di 230V - 50 Hz.

• Assicurarsi che l’impianto elet- trico sia adatto ad erogare, oltre alla corrente di esercizio richie- sta dal ventilconvettore, anche la corrente necessaria per alimen- tare elettrodomestici ed appa- recchi già in uso.

• Effettuare i collegamenti elettrici secondo le leggi e le norme na- zionali vigenti.

• A monte dell’unità prevedere un interruttore omnipolare con di- stanza minima dei contatti di 3 mm.

Occorre sempre effettuare la mes-sa a terra dell’unità.

Togliere sempre l’alimentazioneelettrica prima di accedere allamacchina.

Indicazioniper il collegamento

L’apparecchio è equipaggiato diuna morsettiera di collegamentoposta sulla fiancata interna, latoopposto attacchi idraulici. Il colle-gamento deve essere effettuatorispettando gli schemi elettrici ri-portati sul presente libretto.

L’installatore dovrà prevedere l’in-gresso dei cavi di collegamentoutilizzando gli accessi previsti, ov-vero:

• da muro utilizzando l’apertura posteriore resa disponibile in corrispondenza della fiancata.• da pavimento utilizzando il vano in corrispondenza del piedino (solo apparecchi MV con piedini).

• comunque in prossimità dell’ap- parecchio, nel caso di versioni ad incasso.

ELECTRICALCONNECTIONS

General instructions

• Before installing the fan coil, make sure the rated voltage of the power supply is 230V - 50 Hz.

• Make sure that, in addition to supplying the working current required by the fan coil, the mains electrical supply is also able to supply the current necessary to operate other household appliances and units.

• Perform electrical connections in accordance with laws and regulations in force in the country concerned.

• Upstream of the unit, fit an omnipolar switch with minimum contact distance of 3 mm.

The unit must always be earthed.

Always disconnect the electricalpower supply before opening theunit.

Connection instructions

The unit is fitted with a connectionterminal board on the internal sidepanel on the opposite side to thehydraulic couplings. To connect,respect the wiring diagrams in thisbooklet.

The installer must bring the connectingwires into the unit through the accesspoints provided:

• wall-mounted, using the rear access point corresponding to the side panel.• floor-standing, using the recess inside the foot (MV units with feet only).

• from near the unit in the case of built-in installations.

BRANCHEMENTSELECTRIQUES

ELEKTRO-ANSCHLÜSSE

CONEXIONESELECTRICAS

ELEKTRISCHEAANSLUITINGEN

Instructions

• Avant d’installer le ventilo-con- vecteur vérifier que la tension d’alimentation nominale est de 230V - 50Hz.

• S’assurer que la puissance de l’installation électrique est suffi- sante pour fournir le courant de marche pour le ventilo-convecteur ainsi que le courant nécessaire pour alimenter les électroménagers et les appareils déjà utilisés.

• Effectuer les branchements électriques selon la législation et les normes nationales en vigueur.

• En amont de l’unité prévoir un interrupteur unipolaire avec distance minimum des contacts de 3 mm.

Il faut toujours effectuer la mise àla terre de l’unité.

Débrancher toujours la machineavant d’y accéder.

Indicationspour le raccordement

L’appareil est équipé d’un bornierde raccordement placé sur le côtéintérieur, du côté opposé aux raccordshydrauliques. Le raccordementdoit être effectué en respectantles schémas électriques donnésdans cette notice.

L’installateur devra prévoir l’entréedes câbles de raccordement en uti-lisant les accès prévus, c’est-à-dire:

• sur le mur en utilisant l’ouverture postérieure disponible près du côté.• au sol à travers le pied (seule- ment appareils MV avec pieds).

• toujours à proximité de l’appa- reil, dans le cas de versions à encastrer.

Allgemeine Anweisungen

• Vor der Installation des Klima- konvektors sicherstellen, dass die nominale Versorgungs- spannung 230V - 50 Hz beträgt.

• Sicherstellen, dass die Elektro- anlage in der Lage ist, neben dem Klimakonvektor auch die anderen Haushaltsgeräte zu versorgen.

• Die Elektroanschlüsse müssen gemäß der einschlägigen Gesetze und Vorschriften hergestellt werden.

• Dem Gerät einen allpoligen Schalter mit einer Kontaktöffnung von mindestens 3 mm vorschalten.

Das Gerät vorschriftsmäßig erden.

Vor dem Zugriff auf das Geräte-innere stets die Spannungs-versorgung unterbrechen.

Anleitungenfür den Anschluss

Das Gerät ist mit einer Anschluss-klemmleiste ausgestattet, die ander inneren Seitenwand, gegenüberden Wasseranschlüssen unter-gebracht ist. Für den Anschlussmüssen die in dieser Betriebs-anleitung enthaltenen Schaltplänebefolgt werden.

Der Installateur muss die Durch-gänge der Anschlusskabel an denvorhergesehenen Stellen ausführen,und zwar:

• Von der Wand her unter Verwendung der hinteren Öffnung auf Höhe der Seitenwand.• Vom Boden her unter Verwendung des Hohlraums im Innern des Fußes (nur bei den Geräten MV mit Füßen).• bei Einbaugeräten in jedem Fall in der Nähe des Geräts.

Prescripciones generales

• Antes de instalar el ventilador convector verificar que la tensión nominal de alimentación sea de 230 V - 50 Hz.

• Asegurarse de que la instalación eléctrica sea apta para distribuir, además de la corriente de ejer- cicio requerida por el ventilador convector, la corriente necesaria para alimentar electrodomésticos que ya se estuvieran usando.

• Efectuar las conexiones eléctri- cas de acuerdo con las leyes y las normativas nacionales vigentes.

• Prever, más arriba de la unidad, un interruptor omnipolar con una distancia mínima de los contac- tos de 3mm.

Realizar siempre la toma de tierrade la unidad.

Retirar siempre la corriente eléctri-ca antes de acceder a la máquina.

Indicacionespara la conexión

El aparato está equipado con unacaja de bornes de conexión situa-da en el lateral interno, en el ladoopuesto a las conexiones hidráuli-cas. La conexión se tiene querealizar respetando los esquemaseléctricos que figuran en el pre-sente manual.

El instalador deberá prever la en-trada de los cables de conexiónusando los accesos previstos, esdecir:

• desde la pared usando la aper- tura posterior disponible en el lateral.• desde el suelo usando la aber- tura existente bajo el pie (sólo para los aparatos MV con pies).

• de cualquier forma cerca del aparato, en el caso de versiones empotradas.

Algemene voorschriften

• Alvorens de ventilatorconvector te installeren, wordt gecontroleerd of de nominale voedingsspanning gelijk is aan 230V - 50 Hz.

• Waak erover dat de elektrische installatie in staat is om, naast de bedrijfstroom vereist door de ventilatorconvector, de nodige energie te leveren voor de voeding van de reeds in gebruik zijnde huishoudtoestellen en apparaten.

• De elektrische aansluitingen uitvoeren volgens de geldende nationale wetgevingen en normen.

• Stroomopwaarts van de eenheid wordt een meerpolige schakelaar voorzien met een minimale afstand tussen de polen van 3 mm.

De eenheid moet in elk geval wordenuitgerust met een aardaansluiting.

Koppel altijd eerst de elektrischevoeding los alvorens aan hetapparaat te komen.

Aanwijzingenvoor de aansluiting

Het apparaat is uitgerust met een aansluitklemmenbord dat zichaan de binnenkant bevindt, op dewand tegenover de hydraulischeaansluitingen. De aansluiting dientte worden uitgevoerd conform de schakelschema’s in deze handleiding.

De monteur zal een kabelingangmoeten verwezenlijken door detoegangen die voorzien werden tegebruiken, d.w.z.:

• aan de muur door de beschikbare opening achteraan te gebruiken, overeenstemmend met de zijkant.• aan de grond door de holte in overeenstemming met het voetje te gebruiken (alleen MV-toestellen met voetje).• in elk geval in de nabijheid van het apparaat, voor ingepaste versies.

Page 18:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

BK (III) OG (II) RD (I)

(N) BU

230Vac

1 2 3 4 5 6

Speed

M

PE L N

230Vac50Hz

NLPE 1310 12 1411 157 9854 6

M

E2

E1

IAQ

230V50Hz

CH

BU RD

OG

BK

GN

YE

BK

BU MFC

18 18A

La morsettiera montata sul ventil-convettore è già predisposta per ilcollegamento ai diversi comandisecondo le indicazioni fornite nel-la sezione “Comandi e Schemielettrici”.

Tutti i comandi per installazionea bordo macchina sono dotati dimorsettiera con spinotti predispostiper un collegamento rapido. Unavolta accoppiata questa morsettie-ra alla corrispettiva morsettierapresente sulla fiancata, serrareadeguatamente le viti dei singolimorsetti per garantire il correttocontatto elettrico. La non ottempe-ranza di questa prescrizione causauna grave condizione di pericolo.

The terminal board on the fan coilis designed for connection to thevarious controls following theinstructions provided in the section“Controls and Electrical WiringDiagrams”.

All controls for installation on theunit are provided with a terminalboard with plugs for rapid connection.Connect this terminal board to thecorresponding board on the sidepanel, then tighten the screws onthe individual terminals to guaranteecorrect electrical contact. Failureto follow this instruction could causeserious risks.

Le bornier monté sur le ventilo-convecteur est déjà prêt pour laconnexion des différentes com-mandes selon les instructions fourniesdans la section “Commandes etSchémas électriques”.

Toutes les commandes à installerà bord de la machine sont muniesd’un bornier avec des bornes àbranchement rapide. Quand cebornier est raccordé au borniercorrespondant placé sur le côté,serrer les vis de chaque bornierpour garantir un bon contact élec-trique. Ne pas se conformer à cetteprescription pourrait causer ungrave danger.

Die am Klimakonvektor montierteKlemmleiste ist bereits für denAnschluss der verschiedenenSteuerungen gemäß der Anleitungendes Kapitels “Steuerungen undSchaltpläne” vorbereitet.

Alle am Gerät zu installierendenSteuerungen sind mit Klemmleistemit Steckerstiften für den problem-losen Anschluss ausgestattet.Nachdem die Steckerklemmleistemit der entsprechenden Buchsen-klemmleiste an der Seitenwandverbunden ist, die Schrauben dereinzelnen Klemmen fest anziehen,damit der elektrische Kontaktgewährleistet wird. Die Unterlassungdieser Vorschrift kann schwerwiegendeGefahrensituationen verursachen.

La caja de bornes montada sobreel ventilador convector ya está pre-parada para la conexión a los distin-tos mandos de acuerdo con lasindicaciones dadas en la sección“Mandos y Esquemas eléctricos”.

Todos los mandos que se instala-rán en la máquina estarán provi-stos de caja de bornes con clavijaspreparadas para una conexiónrápida. Una vez que esta caja debornes esté acoplada a la caja debornes correspondiente situada enel lateral, apretar adecuadamentelos tornillos de cada borne paragarantizar un contacto eléctricocorrecto. El no observar esta pre-scripción puede ocasionar un granriesgo.

Het klemmenbord gemonteerd opde ventilatorconvector is al uitgerustvoor de verbinding met de verschillendebedieningen volgens de aanwijzingenin de afdeling “Bedieningen enelektrische schema’s”.

Al de bedieningen voor de installatieaan boord, zijn voorzien van eenklemmenbord met pennen vooreen vlugge verbinding. Wanneerhet klemmenbord aan het over-eenkomstige klemmenbord op dezijkant gekoppeld is, de schroevenvan de klemmen aanspannen omhet correct elektrisch contact teverzekeren. Dit voorschrift nietnaleven, kan zeer gevaarlijk zijn.

COMANDIE SCHEMI ELETTRICI

ELECTRICALCONTROLS ANDWIRING DIAGRAMS

COMMANDESET SCHEMASELECTRIQUES

STEUERGERÄTEUND SCHALTPLÄNE

MANDOSY ESQUEMASELÉCTRICOS

BEDIENINGENEN ELEKTRISCHESCHEMA’S

I venticonvettori sono dotati di mor-settiera con innesto femmina nellaquale deve essere inserita la mor-settiera maschio del comando dafissare a bordo o alla quale vannoallacciati i fili provenienti dal co-mando remoto.

Al comando può essere allacciatoun solo ventilconvettore; per otte-nere il controllo di più ventilcon-vettori con un unico comando ènecessario che ogni apparecchiosia corredato di un selettore di ve-locità SEL che, su segnale del co-mando remoto centralizzato, azio-nerà il proprio apparecchio.

I ventilconvettori dispongono di unventilatore con motore a 6 velocitàdi cui solo 3 collegate alla morset-tiera. Le velocità motore sono otte-nute a mezzo di un autotrasforma-tore. Se si volesse intervenire incantiere sulle velocità è sufficientespostare il collegamento dei cavivelocità (rosso, arancio e nero) col-legati all’autotrasformatore seguen-do la numerazione indicata nelloschema. La connessione nr. 6 del-l’autotrasformatore corrispondealla velocità 1 della tabella ripor-tata sul catalogo commerciale. Aseguire tutte le altre velocità.

The fan coils have a screw terminalboard in which the male terminalboard of the control unit to bemounted on the unit is inserted orto which the wires from the remotecontrol unit are connected.

Only one fan coil can be connectedto the control unit. To control morethan one fan coil with a single controlunit, each appliance must be fittedwith an SEL speed selector whichcontrols that particular unit accordingto the signal received from thecentralised remote control unit.

The fan coil comes equipped witha fan that has a 6 speed motor, ofwhich only 3 are connected to theterminal board. Motor speeds areobtained through an auto-transformer.If wanting to make changes to thespeed on the spot, it is sufficient tomove the speed cable connections(red, orange and black), that areconnected to the auto-transformer,following the numbering in thediagram. The no. 6 connection onthe auto-transformer correspondsto speed 1 from the table includedin the sales catalogue. All otherspeeds follow the same connectionlogic.

Les ventilo-convecteurs sont équipésd’un bornier à vis dans lequel doitêtre branché le bornier mâle de lacommande à fixer sur le ventilo-convecteur ou auquel doivent êtreraccordés les conducteurs provenantde la commande à distance.

A la commande ne peut être raccordéqu’un seul ventilo-convecteur. Pourobtenir le contrôle de plusieursventilo-convecteurs avec une seulecommande, il faut que chaqueappareil soit équipé d’un sélecteurde vitesse SEL. Sur signal de lacommande à distance centralisée,chaque sélecteur actionnera l’ap-pareil sur lequel il est installé.

Les ventilo-convecteurs disposentd’un ventilateur équipé d’un moteurà 6 vitesses dont seulement 3 sontbranchés sur le bornier. Les vitessesdu moteur sont obtenues au moyend’un autotransformateur. Si l’onvoulait intervenir sur le chantier surles vitesses il suffit de déplacer lebranchement des câbles de lavitesse (rouge, orange et noir) reliésà l’autotransformateur en suivant lanumération indiquées sur le schéma.La connexion n.6 de l’autotransformateurcorrespond à la vitesse 1 du tableaumentionné sur le catalogue commercial.Ainsi de suite pour toutes les autresvitesses.

Die Gebläsekonvektoren sind mitSchraubklemmenbrett ausgestattet,in das das am Gerät zu befestigendeSteuerungsklemmenbrett gestecktwerden muss bzw. an das die vonder Fernsteuerung kommenden Drähteangeschlossen werden müssen.

An der Steuerung kann nur einGebläse-konvektor angeschlossenwerden. Um mehrere Gebläse-konvektoren mit einer einzigenSteuerung zu bedienen, muss jedesGerät mit einem Drehzahlwähl-schalter SEL ausgestattet werden,der auf Signal der zentralisiertenFernbedienung sein Gerät betätigt.

Die Gebläse-Konvektoren besitzeneinen Gebläsemotor mit 6 Drehzahl-stufen, von denen nur 3 an dieKlemmleiste angeschlossen sind.Die Motordrehzahlen werden übereinen Spartransformator geregelt.Sollen die Drehzahlen vor Ort geändertwerden, genügt es, die Anschlüsseder am Spartransformator angesch-lossenen Drehzahlkabel (rot, orangeund schwarz) zu versetzen und dabeidie im Plan angegebene Nummerierungzu beachten. Anschluss Nr. 6 desSpartransformators entsprichtDrehzahl 1 der im Verkaufskatalogabgedruckten Tabelle. Analog füralle anderen Drehzahlen.

Los ventiloconvectores están dota-dos de regleta de bornes con tor-nillos en la que debe introducirseel borne macho del mando a fijara bordo o a la que se conectan loscables procedentes del mando adistancia.

Con el control es posible conectarun solo fan coil. Para lograr con-trolar varios fan coils mediante unsolo control es preciso que cadaaparato tenga un selector de velo-cidad, SEL el cual, sobre la basede la señal del mando a distanciacentralizado, accionará al propioaparato.

Los ventiloconvectores cuentancon un ventilador con motor de 6velocidades, de las cuales sólo 3conectadas al bornero. Las veloci-dades del motor se obtienen me-diante un autotransformador. Si enla obra se desea intervenir sobrelas velocidades, es suficiente de-splazar la conexión de los cablesde velocidad (rojo, anaranjado ynegro) conectados al autotransfor-mador siguiendo la numeración quese muestra en el esquema. La co-nexión nr. 6 del autotransformadorcorresponde a la velocidad 1 de latabla presente en el catálogo co-mercial. Y así sucesivamente paralas otras velocidades.

De ventilatorconvectors zijn voorzienvan een klemmenbord met schroevenwaarin het mannelijke klemmenbordvan de bediening dat aan boordbevestigd moet worden of waaraan desnoeren die uit de afstandsbedieningkomen vastgekoppeld moeten worden.

Aan de bediening kan slechtséén ventilatorconvector wordengekoppeld; om meerdere ventilator-convectors te bedienen met éénenkele bediening, moet elk apparaatuitgerust zijn met een snelheids-schakelaar SEL die, op een signaalvan de centrale afstandsbediening,zijn aangesloten apparaat in werkingstelt.

De ventilators-convectors beschikkenover een ventilator met motor op6 snelheden, waarvan slechts 3aangesloten op het klemmenbord.De motorsnelheden worden verkregendoor middel van een autotransformator.Indien men op de werf wenst in tegrijpen op de snelheden, volstaat hetde aansluiting van de snelheidkabels(rood, oranje en zwart) aangeslotenop de autotransformator te verplaatsenvolgens de nummering aangeduid inhet schema. De aansluiting nr. 6 vande autotransformator komt overeen metde snelheid 1 van de tabel vermeld opde commerciële catalogus. Werk naaranalogie voor alle andere snelheden.

Page 19:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

19 19A

MC = Morsettiera del cablaggioMFC = Morsettiera del FAN COILM = MotoventilatoreE = Valvola acqua (IMPIANTO A 2 TUBI)E1 = Valvola acqua CALDA o resistenza elettricaE2 = Valvola acqua FREDDA

= Estate - aria fredda

= Inverno - aria calda

CH = Cambio stagionale esternoIAQ = Filtro elettrico o resistenza elettricaSA = Sonda ariaTMM = Sonda di minima TMM

TME = Sonda di minima TME

Q1 = Sezionatore con un polo protetto da fusibile (raccomandato)

GNYE = Giallo/VerdeRD = Rosso = MinimaOG = Arancio = MediaBK = Nero = MassimaBN = MarroneBU = Blu

MC = Wiring terminal boardMFC = Fan coil terminal boardM = FanE = Water valve (two tube unit)E1 = Hot water valve or electrical heaterE2 = Cold water valve

= Summer - cold air

= Winter - warm air

CH = External season mode switch-overIAQ = Electronic filter or electrical heaterSA = Air probeTMM = TMM low temperature (cut-out thermostat)TME = TME low temperature (cut-out thermostat)Q1 = Circuit breakers with one pole protected by fuse (recommended)

GNYE = Yellow/GreenRD = Red = LowOG = Orange = MediumBK = Black = HighBN = BrownBU = Dark blue

MC = Bornier du câblage

MFC = Bornier du ventilo-convecteurM = MotoventilateurE = Vanne à eau (installation à 2 tubes)E1 = Vanne eau chaude ou résistance électriqueE2 = Vanne eau froide

= Eté - air froid

= Hiver - air chaud

CH = Changement de saison extérieurIAQ = Filtre electronique ou résistance électriqueSA = Sonde airTMM = Sonde de température minimun TMMTME = Sonde de température minimun TMEQ1 = Interrupteur avec une pôle protégé par fusible (recommandé)GNYE = Juane/VertRD = Rouge = MiniOG = Orange = MoyenneBK = Noir = MaxiBN = MarronBU = Bleu foncé

MC = Verdrahtungs- KlemmenbrettMFC = Klemmenbrett des FAN COILM = MotorventilatorE = Wasserventil (Anlage mit zwei Rohren)E1 = Warmwasserventil oder Elektrischer WiderstandE2 = Kaltwasserventil

= Sommer - kalte Luft

= Winter - warme Luft

CH = Externer BetriebsartenwechselIAQ = Elektronsche Filter oder elektrischer WiderstandSA = LuftsondeTMM = Mindesettemperatur- sonde TMMTME = Mindesettemperatur- sonde TMEQ1 = Hauptschalter (empfohlen)

GNYE = Gelb/GroenRD = Rot = MinOG = Orange = MedBK = Schwarz = MaxBN = BraunBU = Blau

MC = Borna de conexión de cableadoMFC = Borna de conexión del ventiloconvectorM = MotoventiladorE = Válvula agua (sistema de climatización a 2 tubos)E1 = Válvula agua caliente o resistencia eléctricaE2 = Válvula agua fría

= Verano - aire frio

= Invierno - aire caliente

CH = Cambio externo de temporadaIAQ = Filtre electronico o resistencia eléctricaSA = Sonda de aireTMM = Sonda TMM de mínima

TME = Sonda TME de mínima

Q1 = Interruptor de maniobra seccionator de una polo protección con fusible (recomendado)GNYE = Amarillo/VerdeRD = Rojo = MínimaOG = Naranja = MediaBK = Negro = MáximaBN = MarrónBU = Azul

MC = Klemmenbord bekabelingMFC = Klemmenbord ventilatorconvectorM = MotorventilatorE = Waterklep (2-buizige installatie)E1 = Klep WARM water of elektrische weerstandE2 = Klep KOUD water

= Zomer - koude lucht

= Winter - warme lucht

CH = Externe seizoenomschakelingIAQ = Elektrische filter of elektrische weerstandSA = LuchtsondeTMM = Uitschakel- thermostaat TMMTME = Uitschakel- thermostaat TMEQ1 = Polige schakelaar met een zekering beveiligd (aanbevolen)

GNYE = Geel/GroenRD = Rood = MinimaOG = Oranje = MediaBK = Zwart = MassimaBN = BruinBU = Donkerblauw

LEGENDA LEGEND LÉGENDE LEGENDE LEYENDA LEGENDE

A A• Installation sans vannes• Thermostat sur le ventilateur

A• Ohne ventile-System• Temperaturregelung am Ventilator

A• Instalación sin válvulas• Termostatación sobre el ventilador

A• Installatie Zonder kleppen• Thermostatische regeling ventilator

B• Installation à 2 tubes (1 vanne)• Thermostatation sur le vanne

B• 2-Leiter-System (1 Ventil)• Temperaturregelung der Ventil

B• Instalación con 2 tubos (1 válvula)• Termostatación sobre la válvula

B• Installatie met 2 leidingen (1 klep)• Thermostatische regeling klep

C• Installation à 4 tubes (2 vannes)• Thermostatation sur les vannes

C• 4-Leiter-System (2 Ventilen)• Temperaturregelung der Ventile

C• Instalación con 4 tubos (2 válvulas)• Termostatación sobre las válvulas

C• Installatie met 4 leidingen (2 kleppen)• Thermostatische regeling kleppen

• Impianto senza valvole• Termostatazione sul motore

A• Without valves installation• Thermostatic control on the fan

B• Impianto 2 tubi (1 valvola)• Termostatazione sulla valvola

B• 2-tube installation (1 valve)• Thermostatic control on the valve

C• Impianto 4 tubi (2 valvole)• Termostatazione sulle valvole

C• 4-tube installation (2 valves)• Thermostatic control on the valves

Page 20:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

5 6N

BU

GN

YE

L 4PE

TMMTMM

NLPE 1310 12 1411 157 9854 6

M230V50Hz

230Vac50Hz

7632 84 1151 12109

421 3 5

MFC

MC

RD

OG

BK

BK

RD

OG

BN

BU

BU

BU

BK

GN

YE

Q1

N L

PE

Type Code

CB 9066300

VARIANTE PER APPLICAZIONE TMM(funzionamento solo invernale)

VARIANT FOR TMM APPLICATION(winter only operation)

VARIANTE FÜR DIE ANBRINGUNG DES TMM(nur Winterbetrieb)

VARIANTE POUR APPLICATION TMM(fonctionnement hiver seulement)

VARIANTE PARA APLICACIONES TMM(funcionamiento sólo invernal)

VARIANTE VOOR TOEPASSING TMM(uitsluitend voor de werking in de winterperiode)

Alimentare con linea elettrica mono-fase, 230V 50Hz, rispettando le po-sizioni di neutro (N) e linea (L) e al-lacciare la messa a terra (PE).

- Tramite l’interruttore (0-1) accen- dere il comando, posizione 1.

- Tramite il commutatore scegliere la velocità desiderata.

Non è adatto per il controllo di val-vole. Non può ricevere il termosta-to di minima elettronico (TME), puòsolo per funzionamento invernale,essere corredato di termostato bi-metallico (TMM-optional) come raf-figurato sullo schema relativo.

Connect to a single phase 230V50Hz power line, respecting theneutral (N) and line (L) positionsand connecting the earth (PE).

- Turn on the control unit by turning the O/I switch to the I position.

- Use the selector to set the required speed.

The control unit cannot be used tocontrol valves. It cannot be connectedto low temperature cut-out thermostat(TME). For winter operation only, itcan be fitted with a bimetal minimumthermostat (TMM optional) as shownin the relative wiring diagram.

Alimenter avec une ligne électriquemonophasée, 230V 50Hz, en respec-tant les positions de neutre (N) etde ligne (L) et raccorder la mise àla terre (PE).

- Allumer la commande à l’aide de l’interrupteur (0 - 1), position 1.

- Choisir la vitesse souhaitée à l’aide du commutateur.

N’est pas adaptée pour le contrôlede vannes. Ne peut pas recevoir lethermostat de température minimumélectronique (TME); peut, unique-ment pour le fonctionnement hiver,être équipé d’un thermostat detempérature minimum bimétallique(TMM-option) comme indiqué surle schéma correspondant.

Stromversorgung einphasig, 230V50Hz, unter Beachtung der Positionenvon Neutralleiter (N) und Zuleiter(L), Erdleiter (PE) anschließen.

- Schalter (0-1) auf Position 1 stellen um die Steuerung einzuschalten.

- Mit dem Wählschalter die gewünschte Drehzahlstufe einstellen.

Nicht geeignet für die Ventilsteuerung.Die Aufnahme des elektronischenMindesttemperatur-Thermostats(TME) ist nicht möglich. Kann - nurfür den Winterbetrieb - wie im ent-sprechenden Schaltplan dargestelltmit Bimetall-Mindesttemperatur-Thermostat (TMM - optional)ausgestattet werden.

Alimentar con red eléctrica mono-fásica, 230V 50 Hz, respetandolas posiciones de neutro (N) y delínea (L) y conectar la toma detierra (PE).

- Mediante el interruptor (0-1) en- cender el control, posición 1.

- Mediante el conmutador elegir la velocidad preferida.

No es apto para el control de vál-vulas. No puede recibir el termo-stato electrónico de mínima (TME);sólo para el funcionamiento inver-nal puede venir equipado con ter-mostato de mínima bimetálico(TMM - opción) como mostrado enel esquema correspondiente.

Voed met een eenfasige lijn van230V 50Hz, waarbij u let op deneutrale (N) en lijnposities (L). Zorgtevens voor een aardaansluiting(PE).

- Met de schakelaar (0-1) zet u de bediening aan, op stand 1.

- Met de omschakelaar kiest u de gewenste snelheid.

Niet geschikt voor de bediening vankleppen. Niet geschikt voor gebruikmet een uitschakelthermostaat (TME),kan enkel in de winter worden uitgerustmet een bimetallieke thermostaat(TMM-optie) zoals geïllustreerd inhet bijhorend schema.

20 20A

CB – Cod. 9066300 CB – Code 9066300 CB – Code 9066300 CB – Art. Nr. 9066300 CB – Cód. 9066300 CB – Code 9066300

I ventilconvettorinelle versioni MV e MVBpossono essere azionati

con uno dei comandiche, di seguito,

vengono descritti.

MV and MVB versionfan coils

can be operatedusing

one of the control unitsdescribed below.

Les ventilo-convecteursdans les versions

MV et MVB peuventêtre actionnés

avec l’une des commandesdécrites ci-après.

Die Gebläsekonvektorenin den ausführungen

MV und MVB können miteiner der nachstehend

beschriebenen Steuerungenbedient werden.

Los fan coils,en las variantes MV y MVB,

pueden ser accionadoscon uno de los controles

que se describena continuación.

De versies MV en MVBvan de ventilatorconvectors

kunnen geactiveerdworden met één

van de hieronder beschrevenbedieningen.

COMANDO ELETTRICOSENZA

TERMOSTATO

ELECTRIC CONTROL UNITWITHOUT

THERMOSTAT

COMMANDE ELECTRIQUESANS

THERMOSTAT

ELEKTRISCHE STEUERUNGOHNE

THERMOSTAT

CONTROL ELÉCTRICOSIN

TERMOSTATO

ELEKTRISCHE BEDIENINGZONDER

THERMOSTAAT

Page 21:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

M E1

9

BKB

K

N

E2

14PE

BU

5

BU

GN

YE

RD

230V

6 1311 124 15L

OG

7

50Hz

108

TMM

MFC

M230V

12

OG

15N 4 10 118L 9

GN

YE

6 13

BK

PE 5

BU

E

BU

14

50Hz

RD BK

7

TMM

MFC BU

E1G

NY

E

E2

RD

14

BK

6 11N

OG

230V

7

BK

50Hz

M

PE L

BU

4 9 10 1512 1385

MFC

M E1

9

BKB

K

N

E2

14PE

BU

5

BU

GN

YE

RD

230V

6 1311 124 15L

OG

7

50Hz

108

TMM

MFC

M230V

12

OG

15N 4 10 118L 9

GN

YE

6 13

BK

PE 5

BU

E

BU

14

50Hz

RD BK

7

TMM

MFC BU

E1G

NY

E

E2

RD

14

BK

6 11N

OG

230V

7

BK

50Hz

M

PE L

BU

4 9 10 1512 1385

MFC

M E1

9

BKB

K

N

E2

14PE

BU

5

BU

GN

YE

RD

230V

6 1311 124 15L

OG

7

50Hz

108

TMM

MFC

M230V

12

OG

15N 4 10 118L 9

GN

YE

6 13

BK

PE 5

BU

E

BU

14

50Hz

RD BK

7

TMM

MFC BU

E1G

NY

E

E2

RD

14

BK

6 11N

OG

230V

7

BK

50Hz

M

PE L

BU

4 9 10 1512 1385

MFC

M230V50Hz

N L

NLPE 1310 12 1411 157 9854 6

230Vac50Hz

7632 84 1151 12109

754 6 8

BU

RD

OG

BKB

U

BK

Q1

PE

32 109 11 121

SA

BU

BU

BU

BN

BN

BK

OG

RD

BK

OG

RD

BU

BU

GY

GY

WH

WH

VT

VT

YE

YE

BK

BK MFC

MC

GN

YE

M230V50Hz

BU

RD

OG

BK

64 5 8 97 1511 141210 13PE L N

BK

BK

GN

YE

BU MFC

TMM

230V

12

OG

15N 4 10 118L 9

GN

YE

6 13

BK

PE 5

BU

E

BU

14

50Hz

M

RD BK

7

MFC

Idoneo per il controllo termostatico(ON-OFF) del ventilatore o della/evalvola/e acqua.

Possibilità di controllo termostatico(ON-OFF) di una valvola sull’ac-qua fredda e di una valvola sull’ac-qua calda o resistenza elettrica.

Può ricevere il termostato di mini-ma TMM che, nel ciclo invernale,arresta il ventilatore se la tempera-tura dell’acqua è inferiore a 30°C elo fa ripartire quando questa rag-giunge i 38°C.

Durante il funzionamento estivo,con ventilatore in OFF, un timermetterà in funzione la ventilazioneper 2 minuti ogni 15 minuti.

- Alimentare con linea elettrica monofase 230/50 rispettando le posizioni di neutro (N) e quella di linea (L). Ricordarsi di allacciare la messa a terra (PE).- Tramite l’interruttore (0-1) accen- dere il comando.- Tramite il commutatore scegliere la velocità.- Tramite il deviatore scegliere la stagione di esercizio:

= riscaldamento

= raffrescamento

- Con la manopola del termostato settare la temperatura ambiente desiderata.

For the thermostatic control (ON/OFF) of the fan or water valve(s).

Possibility of thermostaticallycontrolling (ON/OFF) a water valveon the cold water piping and avalve on the hot water piping oran electric heater.

Can be connected to the lowtemperature cut-out thermostatTMM; during operation in wintermode, this shuts down the fan ifthe water temperature falls below30°C and starts it up again whenit reaches 38°C.

During summer operation with thefan OFF, a timer activates the fanfor two minutes every 15 minutes.

- Connect to a single phase 230V 50Hz power line, respecting the neutral (N) and line (L) positions and connecting the earth (PE).

- Turn on the control unit via the O/I switch.- Use the selector to set the required speed.- Use the deviator to select the season operating mode:

= cooling

= heating

- Use the thermostat knob to select the required room temperature.

Adaptée au contrôle thermostatique(ON-OFF) du ventilateur ou de laou des vannes à eau.

Possibilité de contrôle thermosta-tique (ON-OFF) d’une vanne surl’eau froide et d’une vanne surl’eau chaude ou d’une résistanceélectrique.

Peut recevoir le thermostat detempérature minimum TMM qui, dansle cycle hiver, arrête le ventilateur sila température de l’eau est inférieureà 30°C et le fait repartir quand cettetempérature atteint 38°C.

Pendant le fonctionnement été, avecle ventilateur OFF, un temporisateurfera marcher la ventilation pendant2 minutes toutes les 15 minutes.

- Alimenter avec une ligne électrique monophasée, 230V 50Hz, en respectant les positions de neutre (N) et de ligne (L). Ne pas oublier de raccorder la mise à la terre (PE).- Allumer la commande à l’aide de l’interrupteur (0-1).- Choisir la vitesse à l’aide du commutateur.- Choisir la saison de fonctionne- ment à l’aide de l’inverseur:

= chauffage

= refroidissement

- Régler la température ambiante souhaitée avec le bouton du thermostat.

Geeignet für die Thermostat-steuerung (ON-OFF) des elektrischenVentilators oder des Wasserventilsbzw. der Wasserventile.

Möglichkeit der Thermostatsteuerung(ON-OFF) eines Ventils am Kalt-wasser und eines Ventils am Warm-wasser oder elektrischen Heiz-widerstand.

Der Mindesttemperatur-ThermostatTMM kann aufgenommen werden. ImWinterbetrieb stoppt er den Ventilator,wenn die Wassertemperatur unter30°C liegt, und setzt ihn wieder inGang, wenn sie 38°C erreicht.

Während des Sommerbetriebsund Ventilator auf OFF setzt eineSchaltuhr das Gebläse alle 15Minuten 2 Minuten lang in Gang.

- Stromversorgung einphasig, 230V 50Hz, unter Beachtung der Positionen von Neutralleiter (N) und Zuleiter (L). Nicht vergessen, den Erdleiter (PE) anzuschließen.- Mit dem Schalter (0-1) die Steuerung einschalten.- Mit dem Wählschalter die Drehzahl- stufe einstellen.- Mit dem Wechselschalter die Betriebsart einstellen:

= Heizung

= Kühlung

- Mit dem Drehknopf des Thermostats die gewünschte Raumtemperatur einstellen.

Apto para el control termostático(ON-OFF) del ventilador o de la/lasválvula/s del agua.

Posibilidad de control termostático(ON-OFF) de una válvula en lalínea del agua fría y de una vál-vula en la línea del agua calienteo resistencia eléctrica.

Puede recibir la sonda de tempe-ratura minima TMM la cual, en elciclo invernal detiene el ventiladorsi la temperatura del agua es infe-rior a los 30°C y lo pone de nuevoen marcha cuando la temperaturaalcanza los 38°C.

Durante el funcionamiento vera-niego, con ventilador en OFF, untemporizador pone en marcha laventilación por un plazo de 2 minu-tos cada 15 minutos.

- Alimentar con red eléctrica mono- fásica, 230V 50 Hz, respetando las posiciones de neutro (N), línea (L) y toma de tierra (PE).

- Mediante el interruptor (0-1) en- cender el control.- Mediante el conmutador elegir la velocidad.- Mediante el desviador elegir la temporada de operación:

= calefacción

= refrigeración

- Con el mando del termostato regular la temperatura ambiente deseada.

Geschikt voor de thermostatischeregeling (ON-OFF) van de ventilatorof de waterklep(pen).

Mogelijkheid thermostatischeregeling (ON-OFF) van een klepvoor het koude water en een klepvoor het warme water of de elektrischeweerstand.

Geschikt voor gebruik met deuitschakelthermostaat TMM die,tijdens de wintercyclus, de ventilatoruitschakelt als de temperatuur van hetwater minder dan 30°C bedraagt, enopnieuw inschakelt als de temperatuur38°C bereikt.

In de zomermaanden, als deventilator op OFF staat, schakelteen timer de ventilator elke 15 min.gedurende 2 min. in.

- Voed met een eenfasige lijn van 230V 50Hz, waarbij u let op de neutrale (N) en de lijnposities (L).

- Met de schakelaar (0-1) zet u de bediening aan, op stand 1.- Met de omschakelaar kiest u de gewenste snelheid.- Met de wisselschakelaar kiest u de gewenste seizoenswerking:

= verwarming

= afkoeling

- Met de thermostaatknop stelt u de gewenste omgevingstemperatuur in.

Type Code

CB-T 9066301

21 21A

CB-T – Cod. 9066301 CB-T – Code 9066301 CB-T – Code 9066301 CB-T – Art. Nr. 9066301 CB-T – Cód. 9066301 CB-T – Code 9066301

COMANDO ELETTRICOCON TERMOSTATO

ELETTRONICO

ELECTRIC CONTROL UNITWITH ELECTRONIC

THERMOSTAT

COMMANDE ELECTRIQUEAVEC THERMOSTAT

ELECTRONIQUE

ELEKTRISCHE STEUERUNGMIT ELEKTRONISCHEM

THERMOSTAT

CONTROL ELÉCTRICOCON TERMOSTATO

ELECTRÓNICO

ELEKTRISCHE BEDIENINGMET ELEKTRONISCHE

THERMOSTAAT

B

A

aria caldawarm airair chaudwarme luft

aire calientewarme lucht

aria freddacold airair froidkalte luftaire frio

koude lucht

C+TMMB +TMMC

+TMMA

Page 22:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

M230V50Hz

BU

RD

OG

BK

GN

YE MFC

64 5 8 97 1511 141210 13PE L N

BK

BKBU

BK

CH

E

MFC

230V

12

OG

15N 4 10 118L 9

GN

YE

6 13

BK

PE 5

BU

BU

14

50Hz

M

RD

BK

7

CH

BK

E2

E1

BKOGRDBU

M230V50Hz

MFC

MC

NLPE 1310 12 1411 157 9854 6

230Vac50Hz

7632 84 1151 12109

754 6

BU

BK

Q1

N L

PE

32 11 TME

BU

BU

BU

BN

BN

BKOG

RD

BK

OG

RD

BN

-BK

GY

GY

WH

WH

VT

VT

YE

YE

BK

BK

3 4 52 6 SA

CH

GN

YE

+CHB

+CHC

+CHA

22 22A

Adatto per il cambio stagionaleremoto, centralizzato, o in modoautomatico con l’applicazione diun CHANGE OVER (optional).

Idoneo per il controllo termostatico(ON-OFF) del ventilatore o della/evalvola/e acqua.

Possibilità di controllo termostatico(ON-OFF) di una valvola sull’ac-qua fredda e di una valvola sull’ac-qua calda o resistenza elettrica.

Può ricevere il termostato di mini-ma elettronico TME che, inseritofra le alette della batteria, nel cicloinvernale, arresta l’elettroventila-tore se la temperatura dell’acquaè inferiore a 38°C e lo fa ripartirequando questa raggiunge i 42°C.

Durante il funzionamento estivo,con velocità in OFF, un timer met-terà in funzione il ventilatore per2 minuti ogni 15 minuti.

Il comando è predisposto per ilfunzionamento invernale, alimen-tato con la fase, (L = 230V), conil sesto morsetto del fan coil verràazionato il selettore elettronicoche commuterà il funzionamentoin ciclo estivo.

Solamente sui ventilconvettoricon impianto a 2 tubi, l’alimenta-zione del sesto morsetto può avve-nire in modo automatico tramite ilsensore CHANGE OVER CH 15-25(optional) che, applicato in contattocon il tubo dell’acqua, chiuderà ilcircuito elettrico se la temperaturasarà inferiore a 15°C, realizzandoautomaticamente la commutazioneal ciclo estivo.

For remote centralised seasonalmode change or automatic switch-over with application of a change-over (optional).

For thermostatic control (ON/OFF)of the fan or water valve(s).

Possibility of thermostaticallycontrolling (ON/OFF) a water valveon the cold water piping and a valveon the hot water piping or an electricheater.

Can be connected to the lowtemperature cut-out thermostatTME. Inserted between the fins ofthe heat exchanger during operationin winter mode, this shuts downthe fan if the water temperaturefalls below 38°C and starts it upagain when it reaches 42°C.

During summer operation with thefan OFF, a timer activates the fanfor two minutes every 15 minutes.

The control unit is set for winteroperation. Supplying line voltage(230V) to the sixth terminal of thefan coil activates the electronicselector to switch into summermode.

In two-tube fan coils only, thesixth terminal may be poweredautomatically by means of thechange-over CH 15-25 (optional)sensor. Mounted in contact with thewater tube, this closes the electricalcircuit if the temperature dropsbelow 15°C, automatically switchingthe unit into summer mode.

Adaptée pour le changement desaison à distance centralisé ou enmode automatique en appliquantun CHANGE OVER (option).

Adaptée au contrôle thermostatique(ON-OFF) du ventilateur ou de laou des vannes à eau.

Possibilité de contrôle thermosta-tique (ON-OFF) d’une vanne surl’eau froide et d’une vanne surl’eau chaude ou d’une résistanceélectrique.

Peut recevoir le thermostat detempérature minimum électroniqueTME qui, inséré entre les ailettesde la batterie, dans le cycle hiver,arrête le ventilateur si la tempéra-ture de l’eau est infé-rieure à 38°Cet le fait repartir quand cette tem-pérature atteint 42°C.

Pendant le fonctionnement été, avecventilateur OFF, un temporisateurfera marcher le ventilateur pendant2 minutes toutes les 15 minutes.

La commande est prévue pour lefonctionnement hiver; en alimentantla sixième borne du ventilo-convec-teur avec la phase (L = 230V), lesélecteur électronique sera actionnéet basculera le fonctionnement surle cycle été.

Seulement sur les ventilo-convec-teurs avec installation à 2 tubes,l’alimentation de la sixième bornepeut se faire en mode automatiquepar l’intermédiaire du capteurCHANGE OVER CH 15-25 (option)qui, mis en contact avec la tuyauteriede l’eau, ferme le circuit électriquesi la température est inférieure à15°C, ce qui réalise automatique-ment la commutation sur le cycleété.

Geeignet für den zentralisiertenWechsel der Betriebsart mit Fern-bedienung oder automatisch mitAnbringung eines Change over(optional).

Geeignet für die Thermostatsteuerung(ON-OFF) des elektrischen Ventilatorsoder des Wasserventils bzw. derWasserventile.

Möglichkeit der Thermostatsteuerung(ON-OFF) eines Ventils am Kalt-wasser und eines Ventils am Warm-wasser oder elektrischen Heiz-widerstand.

Der elektronische Mindesttemperatur-Thermostat TME kann aufgenommenwerden. Dieser wird zwischen dieLuftleitlamellen der Batterie eingesetztund im Winterbetrieb stoppt er denElektroventilator, wenn die Wasser-temperatur unter 38°C liegt, undsetzt ihn wieder in Gang, wenn sie42°C erreicht.

Während des Sommerbetriebsund Ventilator auf OFF setzt eineSchaltuhr das Gebläse alle 15Minuten 2 Minuten lang in Gang.

Die Steuerung ist für den Winter-betrieb ausgelegt; indem die sechsteKlemme des fan coil mit der Phase(L=230V) versorgt wird, wird derelektronische Wählschalter betätigt,der den Betrieb auf Sommerumschaltet.

Nur an den Gebläsekonvektorenmit Anlagen mit 2 Rohren kanndie Versorgung der sechsten Klemmeautomatisch mit dem Sensor CHANGEOVER CH 15-25 (Optional) erfolgen,der in Kontakt mit dem Wasserrohrangebracht wird und den Stromkreisschließt, sobald die Temperatur unter15°C liegt, und somit automatischauf Sommerbetrieb umschaltet.

Apto para el cambio remoto detemporada centralizado o en modoautomático con la aplicación deun CHANGE OVER (opción).

Apto para el control termostático(ON-OFF) del ventilador o de la/lasválvula/s del agua.

Posibilidad de control termostático(ON-OFF) de una válvula en lalínea del agua fría y de una vál-vula en la línea del agua calienteo resistencia eléctrica.

Puede recibir el termostato elec-trónico de mínima TME el cual,introducido entre las aletas de labatería, en el ciclo invernal detieneel ventilador si la temperatura delagua es inferior a los 38°C y lo ponede nuevo en marcha cuando latemperatura alcanza los 42°C.

Durante el funcionamiento vera-niego, con ventilador en OFF, untemporizador pone en marcha laventilación por un plazo de 2 mi-nutos cada 15 minutos.

El control está predispuesto parael funcionamiento invernal, alimen-tando con la fase (L = 230V); seráaccionado el sexto borne del fancoil que conmutará el funciona-miento al ciclo veraniego.

Solo en los fan coils con insta-laciones con 2 tubos, la alimen-tación del sexto borne puede pro-ducirse de manera automáticamediante el sensor CHANGE OVERCH 15-25 (opción) que, aplicadoen contacto con el tubo del agua,cerrará el circuito eléctrico si latemperatura es inferior a 15°C,realizando automáticamente laconmutación al ciclo veraniego.

Geschikt voor de afstandsbedieningvan de seizoenomschakeling,gecentraliseerd of automatisch meteen CHANGE OVER(optie).

Geschikt voor de thermostatische regeling (ON-OFF) van de ventilatorvan de waterklep(pen).

Mogelijkheid van thermostatischecontrole (ON-OFF) van een koud-waterklep en een warmwaterklepof elektrische weerstand.

Kan aangesloten worden met deelektronische minimumthermostaatTME die, ingelast tussen de ribbenvan de warmtewisselaar in dewintercyclus, de elektroventilatoruitschakelt indien de temperatuurvan het water minder dan 38°Cbedraagt en hemweer inschakeltwanneer de temperatuur 42°C bereikt.

In de zomermaanden, als deventilator op OFF staat, schakelteen timer de ventilator elke 15 min.gedurende 2 min. in.

De bediening werd voorgeregeldvoor de winterperiode, en gevoedmet een fase (L = 230V). Met dezesde klem van de ventilator-convector wordt de elektronischeschakelaar geactiveerd die debediening overschakelt op dezomercyclus.

Enkel voor ventilatorconvectorsvoorzien van een installatie met2 leidingen, kan de zesde klemautomatisch gevoed worden metbehulp van een CHANGE OVER-sensor CH 15-25 (optie) die, incontact gebracht met de water-leiding, het elektrische circuit onder-breekt als de temperatuur minderdan 15°C bedraagt en automatischoverschakelt op de zomercyclus.

Type Code

CB-C 9066302

CB-C – Cod. 9066302 CB-C – Code 9066302 CB-C – Code 9066302 CB-C – Art. Nr. 9066302 CB-C – Cód. 9066302 CB-C – Code 9066302

COMANDO ELETTRICOCON TERMOSTATO

ELETTRONICO

ELECTRIC CONTROL UNITWITH ELECTRONIC

THERMOSTAT

COMMANDE ELECTRIQUEAVEC THERMOSTAT

ELECTRONIQUE

ELEKTRISCHE STEUERUNGMIT ELEKTRONISCHEM

THERMOSTAT

CONTROL ELÉCTRICOCON TERMOSTATO

ELECTRÓNICO

ELEKTRISCHE BEDIENINGMET ELEKTRONISCHE

THERMOSTAAT

Page 23:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

MFC

GN

YE

230V

12

OG

15N 4 10 118L 96 13

BK

PE 5

BU

BU

14

50Hz

M

RD BK

7

E2

E1

IN1L(230Vac)

CH-IN2L(230Vac)

GN

YE MFC

50Hz230V

M

64 5 8 97 1511 141210 13PE L N

BK

BU

BK

E

BK

OG

RD

BU

IN1L(230Vac)

CH-IN2L(230Vac)

M230V50Hz

BU

RD

OG

BK MFC

MC

GN

YE

TME SA

NLPE 1310 12 1411 157 9854 6

7632 84 1151 12109

BU

BK

230Vac50Hz

Q1

N L

PE

BK

41 2 53 2 63 41 5

VT

BU

BU OG

GY

WH

BN YE

RD

BK

WH

GY

BU

BN

BK

OG

RD

YE

VT

IN1L(230Vac)

CH-IN2L(230Vac)

- Commutazione manuale o auto- matica delle tre velocità del ven- tilatore.- Commutazione manuale o auto- matica del ciclo stagionale (EST- INV).- Possibilità di termostatazione con cambio della velocità automatico e controllo ON-OFF della/e val- vola/e.

- Termostatazione contemporanea delle valvole e del ventilatore.- Termostatazione sulle valvole e funzionamento continuo del ven- tilatore.- Possibilità di applicazione della sonda di minima elettronica TME (optional).- Possibilità di controllo termosta- tico (ON-OFF) di una valvola sull’acqua fredda e di una resi- stenza elettrica riscaldante.

- Durante il funzionamento estivo, con ventilatore in OFF, un timer metterà in funzione la ventilazio- ne per 2,5 minuti ogni 15 minuti.

- Negli impianti a 4 tubi corredati di valvole, con presenza costan- te dei fluidi di alimentazione, esi- ste la possibilità di passare auto- maticamente dalla fase riscal- dante a quella raffrescante (o viceversa) in base allo scosta- mento della temperatura am- biente rispetto a quella fissata con il termostato; con zona mor- ta intermedia di 2°C (Vedi DIP).

- Inserendo sulla morsettiera (IN 1) un segnale elettrico di linea (230V), tramite un timer o un semplice interruttore, è possibile ottenere la variazione della temperatura impostata (-3°C inverno, +3°C estate), oppure l’esclusione to- tale del funzionamento del ventil- convettore, per i periodi nei quali i locali non sono abitati (Vedi DIP).

- Manual or automatic selection of three fan speeds.

- Manual or automatic switching of season mode (SUM/WIN).

- Possibility of thermostatic control with automatic speed change and ON/OFF control of valve(s).

- Simultaneous thermostatic control on the valves and fan.- Thermostatic control on the valves and continuous fan operation.

- Possibility of fitting a TME low temperature cut-out thermostat (optional).- Possibility of thermostatic control (ON/OFF) of a cold water valve and an electric heater.

- During summer operation with the fan OFF, a timer activates the fan for 2,5 minutes every 15 minutes.

- In four-tube installations with valves and constant presence of fluid in the circuits, switching between the heating and cooling phase (and vice versa) can be automatic, according to the difference between room temperature and the temperature set on the thermostat, with an intermediate dead zone of 2°C (see DIP).

- By connecting a line signal (230V) on the terminal board (IN1), a timer or simple switch can be used to vary the set temperature (-3°C winter, +3°C summer) or totally exclude fan coil operation during periods when the premises are unoccupied (see DIP).

- Commutation manuelle ou auto- matique des trois vitesses du ventilateur.- Commutation manuelle ou auto- matique du cycle saisonnier (été- hiver).- Possibilité de thermostatage avec changement de la vitesse auto- matique et contrôle ON-OFF de la ou des vannes.

- Thermostatation simultanée des vannes et du ventilateur.- Thermostatation sur les vannes et fonctionnement continu du ventilateur.- Possibilité d’application de la sonde de température minimum électronique TME (option).- Possibilité de contrôle thermo- statique (ON-OFF) d’une vanne sur l’eau froide et d’une résistance électrique de chauffage.

- Pendant le fonctionnement été, avec le ventilateur OFF, un tempo- risateur fera marcher la ventilation pendant 2,5 minutes toutes les 15 minutes.

- Dans les installations à 4 tuyau- teries équipées de vannes, avec présence constante des fluides d’alimentation, on a la possibilité de passer automatiquement de la phase de chauffage à celle de rafraîchissement (et vice versa) sur la base de l’écart entre la température ambiante et celle réglée sur le thermostat, avec une zone morte intermédiaire de 2°C (cf. DIP).

- En branchant sur le bornier (IN1) un signal électrique de ligne (230V), par l’intermédiaire d’un tempori- sateur ou d’un simple interrupteur, on peut obtenir la variation de la température programmée (moins 3°C hiver, plus 3°C été) ou l’ex- clusion totale du fonctionnement du ventilo-convecteur pendant les périodes durant lesquelles les locaux ne sont pas habités (cf. DIP).

- Manuelle oder automatische Umschaltung der drei Drehzahl- stufen des Ventilators.- Manuelle oder automatische Umschaltung der Betriebsart (SOMMER/WINTER).- Möglichkeit der Thermostat- regelung mit automatischem Wechsel der Drehzahlstufe und ON-OFF-Kontrolle des Ventils bzw. der Ventile.- Gleichzeitige Temperaturregelung der Ventile und des Ventilators.- Temperaturregelung der Ventile und Dauerbetrieb des Ventilators.

- Möglichkeit der Anbringung der elektronischen Mindesttemperatur- sonde TME (optional).- Möglichkeit der Thermostat- steuerung (ON-OFF) eines Ventils am Kaltwasser und eines elektrischen Heizwiderstands.

- Während des Sommerbetriebs und Ventilator auf OFF setzt eine Schaltuhr das Gebläse alle 15 Minuten 2,5 Minuten lang in Gang.

- Bei den mit Ventilen ausgestatteten Anlagen mit 4 Rohren mit konstanter Präsenz der Versorgungsflüssig- keiten, ist die Möglichkeit gegeben, je nach der Abweichung der Raum- temperatur im Vergleich zu der am Thermostat eingegebenen Temperatur automatisch von der Heiz- zur Kühl-phase (und umgekehrt) überzugehen, mit einem Übergangs-Totbereich von 2°C (siehe DIP-Schalter).

- Wenn am Klemmenbrett (IN1) ein elektrisches Netzsignal (230V) eingesetzt wird, kann mit einer Schaltuhr oder einem einfachen Schalter die am Thermostat ein- gestellte Temperatur (minus 3°C beim Winterbetrieb, plus 3°C beim Sommerbetrieb) geändert, oder der Betrieb des Gebläsekonvektors für die Perioden, in denen die Räume unbewohnt sind, ganz ausgeschlossen werden (siehe DIP-Schalter).

- Conmutación manual o auto- mática de las tres velocidades del ventilador.- Conmutación manual o auto- mática del ciclo de temporada (VER-INV).- Posibilidad de regulación termo- stática con cambio automático de la velocidad y control ON-OFF de la/s válvula/s.

- Termostatación de las válvulas y los ventiladores al mismo tiempo.- Termostatación sobre las válvulas y funcionamiento contínuo del ventilador.- Posibilidad de aplicar la sonda electrónica de mínima TME (opción).- Posibilidad de control termostá- tico (ON-OFF) de una válvula en la línea del agua fría y de una resistencia eléctrica calefactora.

- Durante el funcionamiento vera- niego, con ventilador en OFF, un temporizador pone en marcha la ventilación durante 2,5 minutos cada 15 minutos.

- En las instalaciones con 4 tubos provistos de válvulas, con pre- sencia constante de los fluidos de alimentación, cabe la posibi- lidad de pasar automáticamente desde la fase calefactora a la refrescadora (y viceversa) según la diferencia entre la temperatu- ra ambiente y la determinada con el termostato; con zona muerta intermedia de 2 °C (ver DIP).

- Aplicando en la borna de conexión (IN 1) una señal eléctrica de línea (230V), mediante un temporiza- dor o un simple interruptor es posible conseguir la variación de la temperatura establecida (me- nos 3°C invierno, más 3°C ve- rano), o la exclusión total del fun- cionamiento del fan coil durante los periodos en que no se utilizan los cuartos (ver DIP).

- Manuele of automatische instelling van de drie snelheden van de ventilator.- Manuele omschakeling van de seizoencycli (ZOMER-WINTER).

- Mogelijke thermostatische regeling met automatische regeling van de snelheid en ON-OFF controle van de klep(pen).

- Gelijktijdige thermostatische regeling kleppen en ventilator.- Thermostatische regeling kleppen en constante werking van de ventilator.

- Mogelijkheid tot gebruik van de elektronische uitschakelthermostaat TME (optie).- Mogelijke thermostatische regeling (ON-OFF) van een klep voor het koud water en een elektrische weerstand voor de verwarming.

- In de zomermaanden, als de ventilator op OFF staat, schakelt een timer de ventilator elke 15 min. gedurende 2 min. in.

- Voor de installaties met 4 leidingen uitgerust met kleppen en met een constante aanwezigheid van voedingsvloeistoffen, kan auto- matisch worden overgeschakeld van de verwarmende fase naar de afkoelende fase (of vice versa) in functie van het verschil tussen de omgevingstemperatuur en de thermostatisch ingestelde temperatuur; met een dode tussen- zone van 2°C (zie dimschakelaar).

- Door naar het klemmenbord (IN1) een elektrisch lijnsignaal (230) te sturen, met behulp van een timer of een eenvoudige schakelaar, kan de variatie worden bekomen van de ingestelde temperatuur (-3°C in de winter, +3°C in de zomer), ofwel de totale uitschakeling van de ventilatorconvector in de periodes waarin de lokalen niet bewoond zijn (zie dimschakelaar).

Type Code

CB-AU 9066303

23 23A

CB-AU – Cod. 9066303 CB-AU – Code 9066303 CB-AU– Code 9066303 CB-AU – Art. Nr. 9066303 CB-AU – Cód. 9066303 CB-AU – Code 9066303

COMANDOCON TERMOSTATO

ELETTRONICO

ELECTRIC UNITWITH ELECTRONIC

THERMOSTAT

COMMANDEAVEC THERMOSTAT

ELECTRONIQUE

STEUERUNGMIT ELEKTRONISCHEM

THERMOSTAT

CONTROLCON TERMOSTATO

ELECTRÓNICO

BEDIENINGMET ELEKTRONISCHE

THERMOSTAAT

C

A

B

aria caldawarm airair chaudwarme luft

aire calientewarme lucht

aria freddacold airair froidkalte luftaire frio

koude lucht

Page 24:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

N.B.: Per ottenere le funzioni pre-cedentemente descritte, è neces-sario che, prima di fissare il co-mando sul FAN COIL, si interven-ga sul posizionamento degli 4 DIPSwitch, posti sulla scheda, comesotto descritto:

COMMUTAZIONEESTATE / INVERNO

- Possibilità di selezionare il ciclo di funzionamento estivo o inver- nale direttamente dalla pulsan- tiera del comando, oppure, con un segnale elettrico, dalla cen- trale termica o, negli impianti a due tubi, in modo automatico tra- mite un CHANGE-OVER in base alla impostazione selezionata di un Jumper (J1) interno al co- mando.

Funzioni impostabili a mezzoDip Switch

NB: To make the above functionsavailable, before mounting the controlunit on the fan coil, the position ofthe four DIP switches on the electricalboard must be set as follows:

SUMMER / WINTERSWITCHING

- Selecting the summer or winter operating cycle directly from the control keypad, via an electric signal from the heating plant, or automatically using a CHANGE- OVER in two-pipe systems, based on the setting selected by a Jumper (J1) inside the control unit.

Functions can be set usingthe dipswitches

N.B.: pour obtenir les fonctionsprécitées, il est nécessaire, avant defixer la commande sur le ventilo-convecteur, d’intervenir sur lepositionnement des 4 DIP switchessitués sur la carte comme indiquéci-dessous:

COMMUTATIONÉTÉ / HIVER

- Possibilité de sélectionner le cycle de fonctionnement été ou hiver directement à partir du tableau de commande, ou, avec un signal électrique, à partir de la centrale thermique ou, dans les installations à deux tubes, de façon automatique par un inverseur CHANGE-OVER selon la configuration sélectionnée d’un Jumper (J1) à l’intérieur de la commande.

Fonctions programmablesà l’aide du Dip switch

N.B.: Um die oben beschriebenenFunktionen nutzen zu können, müssenvor Befestigung der Steuerung amFan Coil die 4 an der Platine befind-lichen DIP-Schalter wie nachstehendbeschrieben entsprechend positioniertwerden:

SOMMER / WINTEROMSCHAKELING

- Möglichkeit des Einstellens von Sommer- oder Winterbetrieb direkt an der Schalttafel oder, über ein elektrisches Signal, an der Heizung, oder, bei 2-Leiter- Systemen, automatisch mittels CHANGE- OVER, auf Grundlage der Ein- stellung eines in der Steuerung befindlichen Jumpers (J1).

Über Dip Switch einstellbareFunktionen

NB: Para conseguir las funcionesdescritas es preciso que, antes deasegurar el control en el fan coil,se intervenga sobre la posición delos DIP SWITCH, presentes en latarjeta, tal y como se describe acontinuación:

CONMUTACIÓNVERANO / INVIERNO

- Posibilidad de seleccionar el ciclo de funcionamiento verano o invierno directamente desde el teclado del mando, o bien, con una señal eléctrica, de la central térmica o, en las instalaciones con dos tubos, de forma auto- mática mediante un CHANGE- OVER en base a la programación seleccionada por un Jumper (J1) situado dentro del mando.

Funciones programablesa medio Dip Switch

NB.: Om bovenstaande beschrevenfuncties te verkrijgen, regelt u de4 dimschakelaars op de gedrukteschakeling,vóór u de bediening aande ventilator-convector bevestigt,en zoals hieronder beschreven:

OMSCHAKELINGZOMER/WINTER

- Mogelijkheid van cyclusselectie van zomer- of winterfunctie d.m.v. het knopbord op de bediening, ofwel met een elektrisch signaal, uit de thermische centrale of in de installatie met twee leidingen, in automatisch d.m.v. een CHANGE- OVER volgens de ingestelde selectie van een interne Jumper (J1).

Functies die door eendimschakelaar kunnen worden

ingesteld

24 24A

1-2

2-3

Commutazione estate/inverno localeLocal summer/winter switchingSommer/Winterumschaltung in der bedienung Commutation été/hiver localeConmutación Verano/Invierno localPlaatselijke zomer/winter-omschakeling

Commutazione estate/inverno remotaRemote summer/winter switchingSommer/Winter Ferm-UmschaltungCommutation été/hiver à distanceConmutación verano/invierno remotaZomer/winter-omschakeling op afstand

OFF ON

DIP 1 DIP 2

ON OFF

OFF ON

OFF OFF

ON

DIP 3

OFF

Termostatazionesul ventilatore

Thermostatic controlon the fan

Thermostatsur le ventilateur

Temperaturregelungam Ventilator

Termostataciónsobre el ventilador

Thermostatischeregeling ventilator

Termostatazionecontemporanea delle valvole

e del ventilatore

Simultaneous thermostaticcontrol on the valves and fan

Thermostatation simultanéedes vannes et du ventilateur

Gleichzeitige Temperaturregelungder Ventile und des Ventilators

Termostatación de las válvulasy los ventiladoresal mismo tiempo

Gelijktijdige thermostatischeregeling kleppen en ventilator

Termostatazione sulle valvolee funzionamento continuo

del ventilatore

Thermostatic controlon the valves

and continuous fan operation

Thermostatation sur les vanneset fonctionnement continu

du ventilateur

Temperaturregelungder Ventile und Dauerbetrieb

des Ventilators

Termostatación sobrelas válvulas y funcionamiento

contínuo del ventilador

Thermostatische regelingkleppen en constante werking

van de ventilator

Termostatazione sulle valvole,per impianti a 4 tubi,

con commutazione automaticaEstate/Inverno in funzione

della temperatura aria,con zona morta di 2°C

Thermostatic control onthe valves, for 4-pipe systems,with automatic summer/winter

cycle switchingaccording to the air temperature,

with 2°C dead zone

Thermostatation sur les vannes,pour des installations à 4 tubes,avec commutation automatique

été-hiver en fonctionde la température de l’air,avec zone morte de 2°C

Temperaturregelung der Ventilefür 4-Leiter-Systeme

mit automatischerSommer-/Winterumschaltung,

je nach Lufttemperatur,mit Totbereich von 2°C.

Termostatación sobrelas válvulas, para instalacionesde 4 tubos, con conmutaciónautomática verano-invierno

en función de la temperatura del aire, con zona muerta de 2°C.

Thermostatische regeling voorinstallaties met 4 leidingen,

met automatiche omschakelingzomer/winter in functie

van de luchttemperatuur,met dode zone van 2°C

Variazione temperatura +/-3°C Temperature variation +/-3°CVariation

température +/-3°CTemperaturänderung +/-3°C Variación temperatura +/-3°C

Veranderingtemperatuur +/-3°C

Esclusionefunzionamento fan coil

Fan coil operation excludedExclusion

fonctionnement Fan CoilsAusschluss

des Betriebs des Fan CoilsExclusión

funcionamiento Fan CoilsUitschakeling

Ventilatorconvector

Configurazioni IN1 IN1 configurations Configuration IN1 Konfiguration IN1 Configuración IN1 Configuraties IN1

ON

DIP 4

OFF

Estate Summer Eté Sommer Verano Zomer

Inverno Winter Hiver Winterbetrieb Invierno Winter

Configurazioni TME TME configurations Configuration TME Konfiguration TME Configuración TME Configuraties TME

Page 25:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

5 6N

BU

GN

YE

L 4PE

TMMTMM

MFCNLPE 1310 12 1411 157 9854 6

M230V50Hz

OG

BK

RD

BUB

U

BK

GN

YE

PE

L N

Q1

230Vac50Hz

421 3 5

VARIANTEPER L’APPLICAZIONE

DEL TERMOSTATODI MINIMA

TMM

(adatto unicamenteper funzionamento nel cicloinvernale di riscaldamento)

VARIANTFOR APPLICATION

OF TMMLOW TEMPERATURE

CUT-OUT THERMOSTAT

(suitablefor winter heating mode

operation only)

VARIANTEPOUR L’APPLICATION

DU THERMOSTATDE TEMPÉRATURE MINIMUM

(TMM)

(adaptée uniquementau fonctionnement en cycle

hiver de chauffage)

VARIANTEFÜR DIE ANBRINGUNG

DES MINDESTTEMPERATUR-THERMOSTATS

TMM

(geeignet ausschließlichfür den Heizbetrieb

im Winter)

VARIANTEPARA LA APLICACIÓN

DEL TERMOSTATODE MÍNIMA

(TMM)

(apto sólo parael funcionamiento en el ciclo

invernal de calefacción)

VARIANTEVOOR DE TOEPASSINGVAN DE UITSCHAKEL-

THERMOSTAATTMM

(enkel geschikt om te verwarmenin de wintercyclus)

Type Code

MO-3V 9060160

- Togliere il coperchio del comando.

- Fissare la sua base sulla parete con l’ausilio di tasselli e viti.

- Collegare con fili isolati di sezio- ne minima 0,75 mm2, i morsetti del comando con quelli del Fan coil, rispettando lo schema qui raffigurato.

- Alimentare il Fan coil con linea elettrica monofase (230V 50Hz) rispettando le posizioni della linea (L), del neutro (N) e della messa a terra (PE).

- Con l’interruttore (0-1) accende- re il comando (posizione 1).

- Con il commutatore scegliere la velocità del ventilatore per otte- nere la prestazione desiderata.

N.B.: Questo comando non è adat-to per il controllo di valvole acquae non può ricevere il termostato diminima elettronico (TME), che può essere sostituito da un termostatodi minima bimetallico (TMM), postoin contatto con la tubazione, cheinterromperà il filo di alimentazio-ne (L) se l’acqua è inferiore a 30°C.Funzione validaper il solo ciclo invernale.

- Remove the cover of the control unit.- Fix the base to the wall using anchors and screws.

- Connect the control unit terminals to the fan coil terminals, using insulated wires with a minimum cross section of 0.75 mm2 and respecting the wiring diagram alongside.- Connect to a single phase 230V 50Hz power line, respecting the neutral (N) and line (L) positions and connecting the earth (PE).

- Turn on the control unit via the O/I switch (position 4).

- Use the selector to set the correct speed to obtain the performance required.

NB: This control is not suitable forcontrolling water valves and cannotbe connected to the TME lowtemperature cut-out thermostat.This can be replaced by the TMMbimetal minimum thermostat which,placed in contact with the tubes,interrupts the live power line (L) ifthe water falls below a temperatureof 30°C.Valid onlyfor winter mode operation.

- Retirer le couvercle de la com- mande.- Fixer sa base à la paroi à l’aide de chevilles à expansion et de vis.- Raccorder, avec des conducteurs isolés d’une section minimale de 0,75 mm2, les bornes de la com- mande à celles du ventilo-convec- teur, en respectant le schéma représenté ci-contre.- Alimenter le ventilo-convecteur avec une ligne électrique mono- phasée (230 V 50 Hz) en respec- tant les positions de la ligne (L), du neutre (N) et de la mise à la terre (PE).- Allumer la commande à l’aide de l’interrupteur (0 - 1), position 1.

- Choisir la vitesse du ventilateur à l’aide du commutateur pour obtenir la performance souhaitée.

N.B.: Cette commande n’est pasadaptée au contrôle de vannesà eau et ne peut pas recevoir lethermostat de température minimumélectronique (TME), qui peut êtreremplacé par un thermostat detempérature minimale bimétallique(TMM), mis en contact avec latuyauterie, qui interrompra le con-ducteur d’alimentation (L) si l’eauest inférieure à 30°C.Fonction valideuniquement pour le cycle hiver.

- Den Deckel der Steuerung abnehmen. - Die Unterseite mit Dübeln und Schrauben an der Wand befestigen.

- Mit isolierten Leitern, Mindest- querschnitt 0,75 mm2, die Klemmen der Steuerung an jene des Fan Coils anschließen; dabei den hier dargestellten Schaltplan beachten.

- Die Stromzufuhr zum Fan Coil einschalten: Stromversorgung einphasig (230 V, 50 Hz) unter Beachtung der Positionen des Zuleiters (L), des Neutralleiters (N) und des Erdleiters (PE).- Die Steuerung mit dem Schalter (0-1) einschalten (Position 1).

- Mit dem Umschalter die Drehzahl- stufe des Ventilators wählen, um die gewünschte Leistung zu erhalten.

N.B.: Diese Steuerung ist nichtgeeignet für die Kontrolle vonWasserventilen, die Aufnahme deselektronischen Mindesttemperatur-Thermostats (TME), der durch einenBimetall-Mindesttemperatur-Thermostat(TMM) ersetzt werden kann, derin Berührung mit der Rohrleitunginstalliert wird und den Zuleiter(L) unterbricht, wenn die Wasser-temperatur unter 30°C liegt.Diese Funktion ist nurbeim Winterbetrieb möglich.

- Quitar la tapa del control.

- Asegurar su base en la pared utilizando tornillos y tacos de expansión.- Conectar, con hilos aislados que tengan una sección como mínimo de 0,75 mm2, los bornes del con- trol con los del fan coil, según el esquema mostrado al lado.

- Alimentar el fan coil con red eléc- trica monofásica (230V 50Hz) respetando las posiciones de la línea (L), del neutro (N) y de la toma de tierra (PE).

- Con el interruptor (0-1) encen- der el dispositivo de acciona- miento (posición 1).- Con el conmutador elegir la velo- cidad del ventilador para conse- guir la prestación deseada.

NB: Este control no es apto parael control de válvulas del agua y nopuede recibir la sonda electrónicade temperatura mínima (TME) quepuede ser sustituida por una sondabimetálica de temperatura mínima(TMM) colocada en contacto conla tubería y que cortará el hilo dealimentación (L) si la temperaturadel agua es inferior a 30°C.Función válidasólo para el ciclo invernal.

- Verwijder het lid van de bediening.

- Bevestig de basis aan de muur met behulp van pluggen en schroeven.

- Gebruik geïsoleerde draden met een minimum doorsnede van 0,75 mm2

om de klemmen van de bediening te verbinden met de klemmen van de ventilator-convector, volgens het weergegeven schema.- Voed de ventilator-convector met een eenfasige elektrische lijn (230V~50Hz), waarbij u let op de neutrale (N) en lijnposities (L). Zorg tevens voor een aardaansluiting (PE).- Met de schakelaar (0-1) zet u de bediening aan (op stand 1).

- Met de schakelaar kiest u de gewenste snelheid voor de ventilator, met het oog op de gewenste prestaties.

N.B.: Deze bediening is niet geschiktvoor de bediening van waterkleppenen is niet geschikt voor gebruik meteen uitschakelthermostaat (TME),die kan worden vervangen door eenbimetallieke thermostaat (TMM),die de voedingslijn (L) onderbreektals de temperatuur van het wateronder 30°C daalt.Functie alleengeldig voor de wintercyclus.

25 25A

MO-3V – Cod. 9060160 MO-3V – Code 9060160 MO-3V – Code 9060160 MO-3V – Art. Nr. 9060160 MO-3V – Cód. 9060160 MO-3V – Code 9060160

I ventilconvettorinelle versioni MO-IV-IO

possono essere azionaticon uno dei comandi

che, di seguito,vengono descritti.

MO, IV and IO versionfan coils

can be operatedusing

one of the control unitsdescribed below.

Les ventilo-convecteursdans les versionsMO-IV-IO peuvent

être actionnésavec l’une des commandes

décrites ci-après.

Die Gebläsekonvektorenin den ausführungenMO-IV-IO können mit

einer der nachstehendbeschriebenen Steuerungen

bedient werden.

Los fan coils,en las variantes MO-IV-IO,pueden ser accionados

con uno de los controlesque se describena continuación.

De versies MO-IV-IOvan de ventilatorconvectors

kunnen geactiveerdworden met één

van de hieronder beschrevenbedieningen.

COMMUTAZIONE MANUALEDELLE 3 VELOCITÀDEL VENTILATORE,

SENZACONTROLLO

TERMOSTATICO

MANUALSELECTION

OF 3 FAN SPEEDSWITHOUT

THERMOSTATICCONTROL

COMMUTATION MANUELLEDES 3 VITESSES

DU VENTILATEUR,SANS

CONTRÔLETHERMOSTATIQUE

MANUELLEUMSCHALTUNG DER

DREI DREHZAHLSTUFENDES VENTILATORS

OHNETHERMOSTATSTEUERUNG

CONMUTACIÓNMANUAL

DE LAS 3 VELOCIDADESDEL VENTILADOR,

SINCONTROL TERMOSTÁTICO

MANUELE OMSCHAKELINGVAN DE 3 SNELHEDENVAN DE VENTILATOR,

ZONDERTHERMOSTATISCHE

REGELING

Page 26:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

MFCNLPE 1310 12 1411 157 9854 6

BU

BK

GN

YE

1 2 1MC2

MC3

2

MC1

87654321

PE

L N

Q1

230Vac50Hz

CHL(230Vac)

M230V50Hz

BU

RD

OG

BK

MFC

PE

L N

Q1

230Vac50Hz

CH L(230Vac)

1 2 3 4 5 6 7 8

MC1

2

MC3

MC2

121

GN

YE

BK

BU

64 5 8 97 1511 141210 13PE L N

M230V50Hz

BU

RD

OG

BK

E

MFC

PE

L N

Q1

230Vac50Hz

CHL(230Vac)

1 2 3 4 5 6 7 8

MC1

2

MC3

MC2

121

GN

YE

BK BU

64 5 8 97 1511 141210 13PE L N

M230V50Hz

BU

RD

OG

BK

E1E2

Type Code

TMO-T 9060161

C

B

- Idoneo per controllo termosta- tico (ON-OFF) del ventilatore o della/e valvola/e acqua.

- Per una buona sensibilità della sonda, il comando con termosta- to deve essere posizionato sulla parete del locale da climatizzare, all’altezza di circa 1,5 metri e lon- tano da fonti di calore e da cor- renti d’aria fredda.

Togliere il coperchio del coman- do e fissare la sua base sulla parete con l’ausilio di tasselli e viti.

In relazione al tipo di impianto da eseguire, collegare, con fili isolati di sezione 0,75 mm2, i morsetti del comando con quelli del Fan coil seguendo le indicazioni riportate sugli schemi elettrici qui in calce, senza dimenticare di eseguire il collegamento dei ponticelli indi- cati sugli stessi.

Alimentare il Fan coil con linea elettrica monofase (230V 50Hz) rispettando le posizioni: del neutro (N), della linea (L) e della messa a terra (PE).

- Con l’Interruttore (0-1) accen- dere il comando.- Con il Deviatore scegliere la sta- gione di esercizio:

= riscaldamento

= raffrescamento

- Con il Commutatore scegliere la velocità.- Con la Manopola del termostato settare la temperatura ambiente desiderata.

N.B.: Questo comando può rice-vere il termostato di minima elet-tronico TME (MC 3).

- For the thermostatic control (ON-OFF) of the fan or water valve(s).

- To guarantee correct sensor sensitivity, the control unit with thermostat must be positioned at a height of about 1.5 metres on a wall of the room to be air conditioned, away from heat sources and currents of cold air.

Remove the cover of the control unit and fix the base to the wall using anchors and screws.

Depending on the type of installation, connect the control unit terminals to the fan coil terminals, using insulated wires with a minimum cross section of 0,75 mm2 and respecting the wiring diagram below. Remember to connect the jumpers.

Connect the fan coil to a single phase 230V 50Hz power line, respecting the neutral (N) and line (L) positions and connecting the earth (PE).

- Turn on the control via the O/I switch. - Use the deviator to select the season operating mode:

= cooling

= heating

- Use the selector to set the required speed.- Use the thermostat knob to select the required room temperature.

NB: This control can be connectedto the TME electronic minimumthermostat (MC 3).

- Adaptée au contrôle thermostatique (ON-OFF) du ventilateur ou de la ou des vannes à eau.

- Pour une bonne sensibilité de la sonde, la commande avec thermostat doit être placée sur la paroi du local à climatiser, à une hauteur d’environ 1,5 m et loin de toute source de chaleur ou de courants d’air froid.

Retirer le couvercle de la commande et fixer sa base sur la paroi à l’aide de chevilles à expansion et de vis.

En fonction du type d’installation à réaliser, raccorder, avec des conducteurs isolés d’une section de 0,75 mm2, les bornes de la commande à celles du ventilo-con- vecteur en suivant les indications des schémas électriques ci-dessous, sans oublier d’effectuer le raccorde- ment des cavaliers indiqués sur ces mêmes schémas.

Alimenter le ventilo-convecteur avec une ligne électrique mono- phasée (230V 50Hz) en respec- tant les positions: du neutre (N), de la ligne (L) et de la mise à la terre (PE).

- Allumer la commande à l’aide de l’interrupteur (0-1).- Choisir la saison de fonctionne- ment à l’aide de l’inverseur:

= chauffage

= rafraîchissement

- Choisir la vitesse à l’aide du commutateur.- Régler la température ambiante souhaitée avec le bouton du thermostat.

N.B.: Cette commande peut recevoirle thermostat de température minimumélectronique TME (MC 3).

- Geeignet für die Thermostat- steuerung (ON-OFF) des elek- trischen Ventilators oder des Wasserventils bzw. der Wasser- ventile.

- Für eine gute Ansprechempfindlich- keit der Sonde muss die Steuerung mit Thermostat an der Wand des Raumes, der klimatisiert werden soll, angebracht werden, und zwar in einer Höhe von etwa 1,5 Meter und nicht in der Nähe von Wärme- quellen und Zugluft.

Den Deckel der Steuerung abnehmen und ihre Unterseite mit Dübeln und Schrauben an der Wand befestigen.

Je nach Art der Anlage, die realisiert werden soll, mit isolierten Leitern, Mindestquerschnitt 0,75 mm2, die Klemmen der Steuerung an jene des Fan Coils anschließen; dabei die Anleitungen der unten- stehenden elektrischen Schalt- pläne befolgen und nicht vergessen, die dort angegebenen Überbrück- ungen herzustellen.

Die Stromzufuhr zum Fan Coil einschalten: Stromversorgung einphasig (230V, 50Hz) unter Beachtung der Positionen des Neutralleiters (N), des Zuleiters (L) und des Erdleiters (PE).

- Die Steuerung mit dem Schalter (0-1) einschalten. - Mit dem Wechselschalter die Betriebsart wählen:

= Heizung

= Kühlung

- Mit dem Umschalter die Drehzahl- stufe wählen.- Mit dem Drehknopf des Thermostats die gewünschte Raumtemperatur einstellen.

N.B.: Diese Steuerung ist für dieAufnahme des elektronischen Mindest-temperatur-Thermostats (TME)geeignet (MC 3).

- Apto para el control termostático (ON-OFF) del ventilador o de la/las válvula/s del agua.

- Para una buena sensibilidad de la sonda es preciso colocar el control con termostato en la pared del cuarto a climatizar, a una altura de aproximadamente 1,5 m y lejos de fuentes de calor y de corrientes de aire frío.

Quitar la tapa del control y asegu- rar su base en la pared utilizando tornillos y tacos de expansión.

Según el tipo de instalación a realizar conectar, con hilos aisla- dos que tengan una sección de 0,75 mm2, los bornes del control con los del fan coil, según las in- dicaciones presentadas en los esquemas eléctricos mostrados al lado, sin olvidarse de efectuar la conexión de los puentes indi- cados en dichos esquemas.

Alimentar el fan coil con red eléc- trica monofásica (230V 50Hz) respetando las posiciones del neutro (N), de la línea (L) y de la toma de tierra (PE).

- Con el Interruptor (0-1) encen- der el control.- Con el Desviador elegir el tipo de temporada:

= calefacción

= refrigeración

- Con el Conmutador elegir la velocidad.- Con el Mando del termostato regular la temperatura ambiente deseada.

NB: Este control puede recibir eltermostato electrónico de mínimaTME (MC 3).

- Geschikt voor de thermostatische regeling (ON-OFF) van de ventilator van de waterklep(pen).

- Voor een correcte werking van de sonde, moet de bediening van de thermostaat geplaatst worden aan de wand van het lokaal dat moet worden verwarmd/afgekoeld, op een hoogte van circa 1,5 meter en verwijderd van warmtebronnen en koude luchtstromen.

Verwijder het lid van de bediening en bevestig de basis aan de muur met behulp van pluggen en schroeven.

Naargelang het uit te voeren type installatie, gebruik geïsoleerde draden met een minimum doorsnede van 0,75 mm2 om de klemmen van de bediening te verbinden met de klemmen van de ventilatorconvector, volgens de aanduidingen op de elektrische schakelingen hieronder, en let erop verbindingen te voorzien aangeduid op de schema’s.

Voed met een eenfasige lijn van 230V 50Hz, waarbij u let op de neutrale (N) en lijnposities (L). Zorg tevens voor een aardaansluiting (PE).

- Met de schakelaar (0-1) zet u de bediening aan.- Met de wisselschakelaar kiest u de gewenste seizoenwerking:

= verwarming

= afkoeling

- Met de omschakelaar selecteert u de snelheid.- Met de thermostaatknop stelt u de snelheid in.

NB.: Deze bediening is geschiktvoor gebruik met elektronischeuitschakelthermostaat TME (MC 3).

COMANDO ELETTRICOCON TERMOSTATO

ELETTRONICO

ELECTRIC CONTROL UNITWITH ELECTRONIC

THERMOSTAT

COMMANDE ELECTRIQUEAVEC THERMOSTAT

ELECTRONIQUE

ELEKTRISCHE STEUERUNGMIT ELEKTRONISCHEM

THERMOSTAT

CONTROL ELÉCTRICOCON TERMOSTATO

ELECTRÓNICO

ELEKTRISCHE BEDIENINGMET ELEKTRONISCHE

THERMOSTAAT

26 26A

TMO-T – Cod. 9060161 TMO-T – Code 9060161 TMO-T – Code 9060161 TMO-T – Art. Nr. 9060161 TMO-T – Cód. 9060161 TMO-T – Code 9060161

A

aria caldawarm airair chaudwarme luft

aire calientewarme lucht

aria freddacold airair froidkalte luftaire frio

koude lucht

Page 27:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

12345678MC1

2MC3

MC2

1

MIN

MAX

MED

L (230Vac)

CH

21

TMO-T

NLPE 1310 12 1411 157 9854 6

M230V50Hz

230Vac50Hz

7632 84 1151 12109

MFC

MC

OG

BK

RD

BUB

U

BK

GN

YE

Q1

N L

PE

41 2 53

BU B

U

OG

BN RD

BK

BN

BK

OG

RD

RD

OG

BK

BN

BN

Q1

M

BU

BK

8 9

5

5

BK

BU

OG

10

BU

BN

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

2

OG

7

75

BK

BN

PE 14

3

1

NL 15

11

BN

134

6

43

RD

MFC

L N230Vac50Hz

PE PE

230Vac50Hz

Q1

N L

MFC

RD

3 4

6

4 13

BN

11

15L N

1

3

14PE

BN

BK

5 7

7

OG

2

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BN

BU

10O

G

BU

BK

5

5

98

BK

BU

M

27 27A

MC1

MC2

MC3MIN

MED

MAX

E

L (230Vac)

CH

12

12

87654321

M

BU

BK

8 9

5

5

BK

BU

OG

10

BU

BN

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

2

OG

7

75

BK

BN

PE 14

3

1

NL 15

11

BN

134

6

43

RD

MFC

E

L N

Q1

230Vac50Hz

PE

MAX

MED

MIN

MC3

MC2

MC1

E2

E1

CH

L (230Vac)

12

12

87654321

PE

230Vac50Hz

Q1

N L

E1E2

MFC

RD

3 4

6

4 13

BN

11

15L N

1

3

14PE

BN

BK

5 7

7

OG

2

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BN

BU

10

OG

BU

BK

5

5

98

BK

BU

M

TMO-T TMO-T

con 1 valvola - with 1 valveavec 1 vanne - mit 1 Ventilcon 1 válvula - met 1 klep

con 2 valvole - with 2 valvesavec 2 vannes - mit 2 Ventile

con 2 válvulas - met 2 kleppen

senza valvole - without valvessans vannes - Ohne ventile

sin válvulas - Zonder kleppen

Type Code

SEL-CB 9066304

Applicato sulla strutturadei ventilconvettori, consenteil controllo di più apparecchi

(Max 8)su segnale di un unico

comando remoto.

Fitted to the frameof the fan coil, this enables

up to eight unitsto be cotrolled by the signal

from a singleremote control unit.

Appliqué sur la structuredes ventilo-convecteurs, permet

de contrôlerplusieurs appareils (8 maxi)

sur signal d’uneseule commande à distance.

Diese Vorrichtung wird an derStruktur der Gebläsekonvektoren

angebracht und gestattetdie Steuerung meherer (max. 8)

Geräte mit dem Signaleiner einzigen Fernbedienung.

Aplicado en la structurade los fan coils

permite controlar variosaparatos (como máximo 8)

mediante la señalde un único mando a distancia.

Gemonteerd op de structuurvan de ventilatorconvectors,

voor de bediening van meerdereapparaten (max 8) via

een signaal afkomstig van éénenkele afstandsbediening.

SELETTOREDI VELOCITÀ RICEVENTE

SPEED SELECTORRECEIVER

SELECTEURDE VITESSE RECEPTEUR

DREHZAHLWÄHLSCHALTEREMPFÄNGER

SELECTORDE VELOCIDAD RECEPTOR

SNELHEIDSSCHAKELAARONTVANGER

TMO-T conSEL-CB – Cod. 9066304

(MV - MVB)

TMO-T withSEL-CB – Code 9066304

(MV - MVB)

TMO-T avecSEL-CB – Code 9066304

(MV - MVB)

TMO-T mitSEL-CB – Art. Nr. 9066304

(MV - MVB)

TMO-T conSEL-CB – Cód. 9066304

(MV - MVB)

TMO-T metSEL-CB – Code 9066304

(MV - MVB)

Page 28:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

12345678MC1

2MC3

MC2

1

MIN

MAX

MED

L (230Vac)

CH

21

NLPE 1310 12 1411 157 9854 6

M230V50Hz

230Vac50Hz

7632 84 1151 12109

MFC

MC

OG

BK

RD

BUB

U

BK

GN

YE

Q1

N L

PE BU B

U

OG

BN RD

BK

BK

OG

RD

RD

OG

BK

BN

BK

OG

BN

RD

M

BU

BK

8 9

5

BU

OG

10

BU

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

7

75

BK

PE 14

3

NL 15

11

134

6

MFC

L N

Q1

230Vac50Hz

PE PE

230Vac50Hz

Q1

N L

MFC

RD

6

4 13

BN

11

15L N

3

14PE

BK

5 7

7

OG

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BU

10O

G

BU

BK

5

98

BK

BU

M

TMO-T

28 28A

M

BU

BK

8 9

5

BK

BU

OG

10

BU

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

OG

7

75

BK

PE 14

3

NL 15

11

BN

134

6

RD

MFC

E

L N

Q1

230Vac50Hz

PE

MC1

MC2

MC3MIN

MED

MAX

E

L (230Vac)

CH

12

12

87654321

MAX

MED

MIN

MC3

MC2

MC1

PE

230Vac50Hz

Q1

N L

E1E2

MFC

RD

6

4 13

BN

11

15L N

3

14PE

BK

5 7

7

OG

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BU

10

OG

BU

BK

5

98

BK

BU

M

E2

E1

CH

L (230Vac)

12

12

87654321

TMO-T TMO-T

con 1 valvola - with 1 valveavec 1 vanne - mit 1 Ventilcon 1 válvula - met 1 klep

con 2 valvole - with 2 valvesavec 2 vannes - mit 2 Ventile

con 2 válvulas - met 2 kleppen

senza valvole - without valvessans vannes - Ohne ventile

sin válvulas - Zonder kleppen

Type Code

SEL-CR 9066311

Applicato sulla strutturadei ventilconvettori, consenteil controllo di più apparecchi

(Max 8)su segnale di un unico

comando remoto.

Fitted to the frameof the fan coil, this enables

up to eight unitsto be cotrolled by the signal

from a singleremote control unit.

Appliqué sur la structuredes ventilo-convecteurs, permet

de contrôlerplusieurs appareils (8 maxi)

sur signal d’uneseule commande à distance.

Diese Vorrichtung wird an derStruktur der Gebläsekonvektoren

angebracht und gestattetdie Steuerung meherer (max. 8)

Geräte mit dem Signaleiner einzigen Fernbedienung.

Aplicado en la structurade los fan coils

permite controlar variosaparatos (como máximo 8)

mediante la señalde un único mando a distancia.

Gemonteerd op de structuurvan de ventilatorconvectors,

voor de bediening van meerdereapparaten (max 8) via

een signaal afkomstig van éénenkele afstandsbediening.

SELETTOREDI VELOCITÀ RICEVENTE

SPEED SELECTORRECEIVER

SELECTEURDE VITESSE RECEPTEUR

DREHZAHLWÄHLSCHALTEREMPFÄNGER

SELECTORDE VELOCIDAD RECEPTOR

SNELHEIDSSCHAKELAARONTVANGER

TMO-T conSEL-CR – Cod. 9066311

(MO - IV - IO)

TMO-T withSEL-CR – Code 9066311

(MO - IV - IO)

TMO-T avecSEL-CR – Code 9066311

(MO - IV - IO)

TMO-T mitSEL-CR – Art. Nr. 9066311

(MO - IV - IO)

TMO-T conSEL-CR – Cód. 9066311

(MO - IV - IO)

TMO-T metSEL-CR – Code 9066311

(MO - IV - IO)

Page 29:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

MFC

GN

YE

M230V50Hz

BU

RD

OG

BK

NLPE 1310 12 1411 157 9854 6

BU

BK

1 2 1MC2

MC3

2MC1

654321

CH

L(230Vac)

PE

L N

Q1

230Vac50Hz

CH

L(230Vac)

MFC

PE

L N

Q1

230Vac50Hz

GN

YE

M230V50Hz

BU

RD

OG

BK

E

BK

BU

64 5 8 97 1511 141210 13PE L N

MC2

2 11 3 64 1MC1

2 2

MC3

5

CH

L(230Vac)

PE

L N

Q1

230Vac50Hz

MFC

GN

YE

M230V50Hz

BU

RD

OG

BK

E1E2

BK BU

64 5 8 97 1511 141210 13PE L N

6

MC3

21MC1

51 2 23 1MC2

4

Type Code

TMO-T-AU 9060164

C

A

B

Dopo aver scelto le funzioni desi-derate, montare il comando a pa-rete facendo attenzione a posizio-narlo sulla parete del locale da con-dizionare all’altezza di circa 1,5 m,su una parete intermedia e lonta-no da fonti di calore e da correntid’aria fredda; collegare la morset-tiera M1-M2 posta sulla schedaelettronica alla morsettiera postasulla fiancata del ventilconvettoresecondo lo schema selezionato enel rispetto degli schemi elettrici.Per il collegamento tra termostatoe ventilconvettore utilizzare cavicon sezione minima 0,75 mm2.La eventuale sonda di minima ac-qua TME deve essere collegataalla morsettiera M3.

Il comando può gestirele seguenti funzioni:

- Accensione e spegnimento del ventilconvettore.

- Impostazione della temperatura ambiente desiderata (SET).

- Selezione manuale delle tre ve- locità del ventilatore.

- Selezione automatica delle tre velocità del ventilatore in funzio- ne dello scostamento esistente fra la temperatura impostata co- me set e quella ambiente.

- Comando termostatico di aper- tura o chiusura (ON-OFF), sia nel ciclo estivo che in quello inver- nale, della valvola acqua (impian- to a due tubi) o delle due valvole (impianto a quattro tubi).

- Negli impianti a quattro tubi con ventilconvettori corredati di val- vole acqua ON-OFF e con pre- senza costante dei due fluidi (ac- qua calda e acqua fredda) nei circuiti, è possibile ottenere la commutazione automatica dalla fase riscaldamento a quella di raffreddamento, e viceversa, in funzione dello scostamento esi- stente fra la temperatura am- biente e la temperatura settata, con zona morta di ~2°C.

After choosing the required functions,mount the control unit to the wall,taking care to position it on an innerwall in the room being air-conditionedat a height of about 1.5 m, awayfrom sources of heat and currentsof cold air. Connect terminal boardM1-M2 on the electronic board tothe terminal board located on theside of the fan coil, according tothe selected layout and followingthe wiring diagrams.For the connection between thethermostat and the fan coil, usecables with a minimum cross-sectionof 0.75 mm2.Any TME minimum water probemust be connected to terminalboard M3.

The control unit can managethe following functions:

- Turning the fan coil on and off.

- Setting and reading the required room temperature (SET).

- Manual selection of the three fan speeds.

- Automatic selection of the three fan speeds according to the difference between the set temperature and the room temperature.

- In both summer and winter cycle, thermostatic control of opening and closing (ON/OFF) of the water valve (two-pipe installation) or the two valves (four-pipe installation).

- In four-pipe fan coils with ON/OFF water valves and the two liquids (hot and cold water) constantly present in the circuits, automatic switching between heating and cooling phases according to the difference between set temperature and room temperature with a dead zone of ~2°C.

Après avoir choisi les fonctionsvoulues, monter la commandemurale en veillant à la placer sur lemur du local à conditionner à unehauteur de 1,5 m environ, sur unecloison et loin de sources de chaleuret de courants d’air froid; connecterle bornier M1-M2 placé sur la carteélectronique au bornier placé surle flanc du ventilo-convecteur selonle schéma sélectionné et en respec-tant les schémas électriques.Pour la connexion entre thermostatet ventilo-convecteur utiliser descâbles de section minimum 0,75 mm2.Si on installe une sonde de tempé-rature minimale eau TME, elle doitêtre raccordée au bornier M3.

La commande peut gérerles fonctions suivantes:

- Mise en marche et arrêt du ventilo-convecteur.

- Programmation de la température ambiante voulue (SET).

- Sélection manuelle des trois vitesses du ventilateur.

- Sélection automatique des trois vitesses du ventilateur en fonction de l’écart existant entre la tempé- rature programmée et la tempé- rature ambiante.

- Commande thermostatique d’ou- verture ou de fermeture (ON-OFF), en cycle été comme en cycle hiver, de la vanne eau (installation à deux tubes) ou des deux vannes (installation à quatre tubes).

- Dans les installations à quatre tubes avec des ventilo-convec- teurs munis de vannes eau ON- OFF et avec la présence constante des deux fluides (eau chaude et eau froide) dans les circuits, il est possible d’obtenir la commutation automatique de la phase chauffage à celle de refroidissement, et vice versa, en fonction de l’écart entre la température ambiante et la température programmée, avec une zone morte de ~2°C.

Nachdem die gewünschten Funktioneneingestellt wurden, das Steuer-gerät an einer Innenwand in einerHöhe von zirka 1,5 m und fern vonWärmequellen und Kaltluftströmenmontieren; die Klemmleiste M1-M2an der Elektronikplatine gemäß desgewählten Schemas und unter Ein-haltung der Schaltpläne mit derKlemmleiste an der Seite des Lüft-ungskonvektors verbinden.Für die Verbindung zwischenThermostat und LüftungskonvektorDrähte mit einem Querschnitt vonmin. 0,75 mm2 benutzen.Die eventuelle MindesstandsondeTME wird an die Klemmleiste M3angeschlossen.

Das Steuergerät kann diefolgenden Funktionen verwalten:

- Ein- und Ausschalten des Lüft- ungskonvektors.

- Einstellung der gewünschten Raumtemperatur (SET).

- Manuelle Einstellung der drei Ventilatordrehzahlen.

- Automatische Einstellung der drei Ventilatordrehzahlen entsprechend der Abweichung zwischen ein- gestellter Set Temperatur und der effektiven Raumtemperatur.

- Thermostatsteuerung des Wasser- ventils (ON-OFF) bei 2-Leiter- Systemen, oder der beiden Wasser- ventile bei 4-Leiter-Systemen in Kühl- und Heizbetrieb.

- Bei 4-Leiter-Systemen mit Lüft- ungskonvektoren mit Wasser- ventilen ON-OFF und bei ständiger Präsenz der beiden Flüssigkeiten (Warmwasser und Kaltwasser) in den Kreisen, ist die automatische Umschaltung von Heiz- zu Kühl- betrieb und umgekehrt möglich, je nach der vorliegenden Abweichung zwischen Raumtemperatur und eingestellter Temperatur, mit einem Totbereich von ~2°C.

Después de haber elegido las fun-ciones deseadas, montar el mandode pared poniendo atención encolocarlo en la pared del local aacondicionar a una altura de 1,5 maproximadamente, en un tabiquey lejos de las fuentes de calor y delas corrientes de aire frío; conectarla caja de bornes M1-M2 situadasobre la tarjeta electrónica a la cajade bornes situada en el lado delventilador convector según el esque-ma seleccionado y respetando losesquemas eléctricos.Para la conexión entre el termo-stato y el ventilador convector usarcables con una sección mínim de0,75 mm2.La eventual sonda de mínima aguaTME se tiene que conectar a lacaja de bornes M3.

El mando puede gestionarlas siguientes funciones:

- Encendido y apagado del venti- lador convector.

- Introducción de la temperatura ambiente deseada (SET).

- Selección manual de las tres velocidades del ventilador.

- Selección automática de las tres velocidades del ventilador en función de la diferencia existente entre la temperatura introducida como set y la temperatura ambiente.

- Mando termostático de abertura o cierre (ON-OFF), tanto en el ciclo de verano como en el de invierno, de la válvula de agua (instalación con dos tubos) o de las dos válvulas (instalación con cuatro tubos).

- En las instalaciones con cuatro tubos con ventiladores convec- tores equipados con válvulas de agua ON-OFF y con presencia constante de los dos fluidos (agua caliente y agua fría) en los cir- cuitos, se puede obtener la con- mutación automática de la fase de calentamiento a la de enfria- miento, y viceversa, en función de la diferencia existente entre la temperatura ambiente y la tem- peratura instaurada, con una zona muerta de ~2°C.

Na de functies te hebben gekozen,de bediening aan de muur bevestigen.Er aandacht aan besteden dat hijgemonteerd wordt op de wand vanhet lokaal, dat moet verwarmd/afgekoeld worden, op een hoogtevan circa 1,5 meter en ver vanwarmtebronnen en koude lucht-stromingen; het klemmenbord M1-M2op de gedrukte schakelingenverbinden met het klemmenbord opde zijkant van de ventilatorconvectorvolgens het gekozen schema ende elektrische schema’s.Voor de verbinding tussen dethermostaat en de ventilatorconvector,kabels gebruiken met een minimum-doorsnede van 0,75 mm2.De eventuele elektronische water-sonde TME moet verbonden zijnmet het klemmenbord M3.

De bediening kan de volgendefuncties in werking stellen:

- In- en uitschakeling van de ventilatorconvector.

- Instelling van de gewenste kamer- temperatuur (SET).

- Manuele selectie van de drie versnellingen van de ventilator.

- Automatische selectie van de drie versnellingen van de ventilator in functie van de deviatie tussen de ingestelde temperatuur en de kamertemperatuur.

- Thermostatische regeling (ON- OFF), zowel in de zomer- als in de wintercyclus, van de waterklep (installatie met 2 leidingen) of van de twee kleppen (installatie met 4 leidingen).

- In de installaties met 4 leidingen, met ventilatorconvectors voorzien van waterkleppen ON-OFF en met constante aanwezigheid van de twee vloeistoffen (warm water en koud water) in de circuits, is het mogelijk de automatische omschakeling te verkrijgen van de verwarmfase naar de afkoelfase en omgekeerd in functie van de deviatie tussen de ingestelde temperatuur en de kamer- temperatuur, met dode zone van ~2°C.

COMANDO ELETTRICOCON TERMOSTATO

ELETTRONICO

ELECTRIC CONTROL UNITWITH ELECTRONIC

THERMOSTAT

COMMANDE ELECTRIQUEAVEC THERMOSTAT

ELECTRONIQUE

ELEKTRISCHE STEUERUNGMIT ELEKTRONISCHEM

THERMOSTAT

CONTROL ELÉCTRICOCON TERMOSTATO

ELECTRÓNICO

ELEKTRISCHE BEDIENINGMET ELEKTRONISCHE

THERMOSTAAT

29 29A

TMO-T-AU – Cod. 9060164 TMO-T-AU – Code 9060164 TMO-T-AU – Code 9060164 TMO-T-AU – Art. Nr. 9060164 TMO-T-AU – Cód. 9060164 TMO-T-AU – Code 9060164

aria caldawarm airair chaudwarme luft

aire calientewarme lucht

aria freddacold airair froidkalte luftaire frio

koude lucht

Page 30:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

1-2

2-3

Commutazione estate/inverno localeLocal summer/winter switchingSommer/Winterumschaltung in der bedienung Commutation été/hiver localeConmutación Verano/Invierno localPlaatselijke zomer/winter-omschakeling

Commutazione estate/inverno remotaRemote summer/winter switchingSommer/Winter Ferm-UmschaltungCommutation été/hiver à distanceConmutación verano/invierno remotaZomer/winter-omschakeling op afstand

ON ON

DIP 1 DIP 2

ON OFF

OFF ON

OFF OFF

Termostatazionesul ventilatore

Thermostatic controlon the fan

Thermostatsur le ventilateur

Temperaturregelungam Ventilator

Termostataciónsobre el ventilador

Thermostatischeregeling ventilator

Termostatazionecontemporanea delle valvole

e del ventilatore

Simultaneous thermostaticcontrol on the valves and fan

Thermostatation simultanéedes vannes et du ventilateur

Gleichzeitige Temperaturregelungder Ventile und des Ventilators

Termostatación de las válvulasy los ventiladoresal mismo tiempo

Gelijktijdige thermostatischeregeling kleppen en ventilator

Termostatazione sulle valvolee funzionamento continuo

del ventilatore

Thermostatic controlon the valves

and continuous fan operation

Thermostatation sur les vanneset fonctionnement continu

du ventilateur

Temperaturregelungder Ventile und Dauerbetrieb

des Ventilators

Termostatación sobrelas válvulas y funcionamiento

contínuo del ventilador

Thermostatische regelingkleppen en constante werking

van de ventilator

Termostatazione sulle valvole,per impianti a 4 tubi,

con commutazione automaticaEstate/Inverno in funzione

della temperatura aria,con zona morta di 2°C

Thermostatic control onthe valves, for 4-pipe systems,with automatic summer/winter

cycle switchingaccording to the air temperature,

with 2°C dead zone

Thermostatation sur les vannes,pour des installations à 4 tubes,avec commutation automatique

été-hiver en fonctionde la température de l’air,avec zone morte de 2°C

Temperaturregelung der Ventilefür 4-Leiter-Systeme

mit automatischerSommer-/Winterumschaltung,

je nach Lufttemperatur,mit Totbereich von 2°C.

Termostatación sobrelas válvulas, para instalacionesde 4 tubos, con conmutaciónautomática verano-invierno

en función de la temperatura del aire, con zona muerta de 2°C.

Thermostatische regeling voorinstallaties met 4 leidingen,

met automatiche omschakelingzomer/winter in functie

van de luchttemperatuur,met dode zone van 2°C

30 30A

- Collegando la sonda di minima (accessorio TME posta tra le alette della batteria di scambio termico), nel solo ciclo invernale, il ventilatore entrerà in funzione solamente se la temperatura del- l’acqua è superiore a 42°C e ver- rà fermato quando quest’ultima è inferiore a 38°C.

COMMUTAZIONEESTATE / INVERNO

- Possibilità di selezionare il ciclo di funzionamento estivo o inver- nale direttamente dalla pulsan- tiera del comando, oppure, con un segnale elettrico, dalla cen- trale termica o, negli impianti a due tubi, in modo automatico tra- mite un CHANGE-OVER in base alla impostazione selezionata di un Jumper (J1) interno al co- mando.

Funzioni impostabili a mezzoDip Switch

- In the winter cycle only, if a minimum sensor is connected (TME accessory located between the fins of the heat exchange coil), the fan coil will start up only if the water temperature rises above 42°C and shut down when water temperature drops below 38°C.

SUMMER / WINTERSWITCHING

- Selecting the summer or winter operating cycle directly from the control keypad, via an electric signal from the heating plant, or automatically using a CHANGE- OVER in two-pipe systems, based on the setting selected by a Jumper (J1) inside the control unit.

Functions can be set usingthe dipswitches

- En connectant la sonde de tem- pérature minimale (accessoire TME placée entre les ailettes de la batterie d’échange thermique), en cycle hiver seulement, le ven- tilateur ne se mettra en marche que si la température de l’eau est supérieure à 42°C et s’arrêtera quand celle-ci est inférieure à 38°C.

COMMUTATIONÉTÉ / HIVER

- Possibilité de sélectionner le cycle de fonctionnement été ou hiver directement à partir du tableau de commande, ou, avec un signal électrique, à partir de la centrale thermique ou, dans les installations à deux tubes, de façon automatique par un inverseur CHANGE-OVER selon la configuration sélectionnée d’un Jumper (J1) à l’intérieur de la commande.

Fonctions programmablesà l’aide du Dip switch

- Durch Anschließen der Mindest- sonde (Zubehör TME zwischen den Lamellen des Wärmetauscher- registers, wird der Ventilator nur eingeschaltet, wenn die Wasser- temperatur über 42°C beträgt, und ausgeschaltet, wenn sie bis unter 38°C absinkt.

SOMMER / WINTEROMSCHAKELING

- Möglichkeit des Einstellens von Sommer- oder Winterbetrieb direkt an der Schalttafel oder, über ein elektrisches Signal, an der Heizung, oder, bei 2-Leiter- Systemen, automatisch mittels CHANGE- OVER, auf Grundlage der Ein- stellung eines in der Steuerung befindlichen Jumpers (J1).

Über Dip Switch einstellbareFunktionen

- Conectando la sonda de mínima (accesorio TME situado entre las aletas de la batería de cambio térmico), en el ciclo invernal, el ventilador entrará en función úni- camente si la temperatura del agua es superior a 42°C y se cerrará cuando esta última sea inferior a 38°C.

CONMUTACIÓNVERANO / INVIERNO

- Posibilidad de seleccionar el ciclo de funcionamiento verano o invierno directamente desde el teclado del mando, o bien, con una señal eléctrica, de la central térmica o, en las instalaciones con dos tubos, de forma auto- mática mediante un CHANGE- OVER en base a la programación seleccionada por un Jumper (J1) situado dentro del mando.

Funciones programablesa medio Dip Switch

- Door de elektronische water- sonde, enkel in de wintercyclus, te verbinden (accessoire TME tussen de ribben van de reeks warmtewisselaars geplaatst) wordt de ventilator enkel ingeschakeld indien de temperatuur van het water meer dan 42°C bereikt en zal uitgeschakeld worden wanneer ze lager dan 38°C is.

OMSCHAKELINGZOMER/WINTER

- Mogelijkheid van cyclusselectie van zomer- of winterfunctie d.m.v. het knopbord op de bediening, ofwel met een elektrisch signaal, uit de thermische centrale of in de installatie met twee leidingen, in automatisch d.m.v. een CHANGE- OVER volgens de ingestelde selectie van een interne Jumper (J1).

Functies die door eendimschakelaar kunnen worden

ingesteld

Page 31:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

TMO-T-AU conSEL-CB – Cod. 9066304

(MV - MVB)

TMO-T-AU withSEL-CB – Code 9066304

(MV - MVB)

TMO-T-AU avecSEL-CB – Code 9066304

(MV - MVB)

TMO-T-AU mitSEL-CB – Art. Nr. 9066304

(MV - MVB)

TMO-T-AU conSEL-CB – Cód. 9066304

(MV - MVB)

TMO-T-AU metSEL-CB – Code 9066304

(MV - MVB)

Applicato sulla strutturadei ventilconvettori, consenteil controllo di più apparecchi

(Max 8)su segnale di un unico

comando remoto.

Fitted to the frameof the fan coil, this enables

up to eight unitsto be cotrolled by the signal

from a singleremote control unit.

Appliqué sur la structuredes ventilo-convecteurs, permet

de contrôlerplusieurs appareils (8 maxi)

sur signal d’uneseule commande à distance.

Diese Vorrichtung wird an derStruktur der Gebläsekonvektoren

angebracht und gestattetdie Steuerung meherer (max. 8)

Geräte mit dem Signaleiner einzigen Fernbedienung.

Aplicado en la structurade los fan coils

permite controlar variosaparatos (como máximo 8)

mediante la señalde un único mando a distancia.

Gemonteerd op de structuurvan de ventilatorconvectors,

voor de bediening van meerdereapparaten (max 8) via

een signaal afkomstig van éénenkele afstandsbediening.

SELETTOREDI VELOCITÀ RICEVENTE

SPEED SELECTORRECEIVER

SELECTEURDE VITESSE RECEPTEUR

DREHZAHLWÄHLSCHALTEREMPFÄNGER

SELECTORDE VELOCIDAD RECEPTOR

SNELHEIDSSCHAKELAARONTVANGER

123456

MC1

2MC3

MC2

1

MIN

MAX

MED

L (230Vac)

CH

21

NLPE 1310 12 1411 157 9854 6

M230V50Hz

230Vac50Hz

7632 84 1151 12109

MFC

MC

OG

BK

RD

BUB

U

BK

GN

YE

Q1

N L

PE

41 2 53

BU B

U

OG

BN RD

BK

BN

BK

OG

RD

RD

OG

BK

BN

BN

M

BU

BK

8 9

5

5

BK

BU

OG

10

BU

BN

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

2

OG

7

75

BK

BN

PE 14

3

1

NL 15

11

BN

134

6

43

RD

MFC

L N

Q1

230Vac50Hz

PE PE

230Vac50Hz

Q1

N L

MFC

RD

3 4

6

4 13

BN

11

15L N

1

3

14PE

BN

BK

5 7

7

OG

2

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BN

BU

10O

G

BU

BK

5

5

98

BK

BU

M

TMO-T-AU

31 31A

MC1

MC2

MC3MIN

MED

MAX

E

12

12

654321

L (230Vac)

CH

M

BU

BK

8 9

5

5

BK

BU

OG

10

BU

BN

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

2

OG

7

75

BK

BN

PE 14

3

1

NL 15

11

BN

134

6

43

RD

MFC

E

L N

Q1

230Vac50Hz

PE

MAX

MED

MIN

MC3

MC2

MC1

E2

E1

12

12

654321

CH

L (230Vac)

PE

230Vac50Hz

Q1

N L

E1E2

MFC

RD

3 4

6

4 13

BN

11

15L N

1

3

14PE

BN

BK

5 7

7

OG

2

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BN

BU

10

OG

BU

BK

5

5

98

BK

BU

M

TMO-T-AU TMO-T-AU

con 1 valvola - with 1 valveavec 1 vanne - mit 1 Ventilcon 1 válvula - met 1 klep

con 2 valvole - with 2 valvesavec 2 vannes - mit 2 Ventile

con 2 válvulas - met 2 kleppen

senza valvole - without valvessans vannes - Ohne ventile

sin válvulas - Zonder kleppen

Type Code

SEL-CB 9066304

Page 32:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

123456

MC1

2MC3

MC2

1

MIN

MAX

MED

L (230Vac)

CH

21

NLPE 1310 12 1411 157 9854 6

M230V50Hz

230Vac50Hz

7632 84 1151 12109

MFC

MC

OG

BK

RD

BUB

U

BK

GN

YE

Q1

N L

PE BU B

U

OG

BN RD

BK

BK

OG

RD

RD

OG

BK

BN

M

BU

BK

8 9

5

BK

BU

OG

10

BU

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

OG

7

75

BK

PE 14

3

NL 15

11

BN

134

6

RD

MFC

L N

Q1

230Vac50Hz

PE PE

230Vac50Hz

Q1

N L

MFC

RD

6

4 13

BN

11

15L N

3

14PE

BK

5 7

7

OG

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BU

10O

G

BU

BK

5

98

BK

BU

M

TMO-T-AU

32 32A

MAX

MED

MIN

MC3

MC2

MC1

E2

E1

12

12

654321

CH

L (230Vac)

PE

230Vac50Hz

Q1

N L

E1E2

MFC

RD

6

4 13

BN

11

15L N

3

14PE

BK

5 7

7

OG

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BU

10

OG

BU

BK

5

98

BK

BU

M

MC1

MC2

MC3MIN

MED

MAX

E

12

12

654321

L (230Vac)

CH

M

BU

BK

8 9

5

BK

BU

OG

10

BU

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

OG

7

75

BK

PE 14

3

NL 15

11

BN

134

6

RD

MFC

E

L N

Q1

230Vac50Hz

PE

TMO-T-AUTMO-T-AU

con 1 valvola - with 1 valveavec 1 vanne - mit 1 Ventilcon 1 válvula - met 1 klep

con 2 valvole - with 2 valvesavec 2 vannes - mit 2 Ventile

con 2 válvulas - met 2 kleppen

senza valvole - without valvessans vannes - Ohne ventile

sin válvulas - Zonder kleppen

Type Code

SEL-CR 9066311

Applicato sulla strutturadei ventilconvettori, consenteil controllo di più apparecchi

(Max 8)su segnale di un unico

comando remoto.

Fitted to the frameof the fan coil, this enables

up to eight unitsto be cotrolled by the signal

from a singleremote control unit.

Appliqué sur la structuredes ventilo-convecteurs, permet

de contrôlerplusieurs appareils (8 maxi)

sur signal d’uneseule commande à distance.

Diese Vorrichtung wird an derStruktur der Gebläsekonvektoren

angebracht und gestattetdie Steuerung meherer (max. 8)

Geräte mit dem Signaleiner einzigen Fernbedienung.

Aplicado en la structurade los fan coils

permite controlar variosaparatos (como máximo 8)

mediante la señalde un único mando a distancia.

Gemonteerd op de structuurvan de ventilatorconvectors,

voor de bediening van meerdereapparaten (max 8) via

een signaal afkomstig van éénenkele afstandsbediening.

SELETTOREDI VELOCITÀ RICEVENTE

SPEED SELECTORRECEIVER

SELECTEURDE VITESSE RECEPTEUR

DREHZAHLWÄHLSCHALTEREMPFÄNGER

SELECTORDE VELOCIDAD RECEPTOR

SNELHEIDSSCHAKELAARONTVANGER

TMO-T-AU conSEL-CR – Cod. 9066311

(MO - IV - IO)

TMO-T-AU withSEL-CR – Code 9066311

(MO - IV - IO)

TMO-T-AU avecSEL-CR – Code 9066311

(MO - IV - IO)

TMO-T-AU mitSEL-CR – Art. Nr. 9066311

(MO - IV - IO)

TMO-T-AU conSEL-CR – Cód. 9066311

(MO - IV - IO)

TMO-T-AU metSEL-CR – Code 9066311

(MO - IV - IO)

Page 33:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

1

2

3

4

5

6

8

7

DIP ONTermostatazione

sul motore

OFFTermostatazione

sulle valvole

Termostatazionesu una valvola

(impianto a 2 tubi)

Termostatazionesu due valvole

(impianto a 4 tubi)

Presenza dellasonda di minimaelettronica TME

Commutazionestagionale

dal pulsantedell’unità

Assenza dellasonda di minimaelettronica TME

Commutazionestagionale remota

Presenzadi filtro

aria elettronico“CRYSTALL”

Presenzadi resistenza

elettricacomplementare

Impianti a 4 tubi,passaggioautomatico

dal riscaldamentoal raffrescamento

e viceversa,con zona morta

Assenza di cambioautomaticostagionale,

con zona mortaintermedia

Variazionedel Set notturno(-3°C inverno,+3°C estate)

Esclusionedel funzionamentodel ventilconvettore

9Termostatazione

sulle valvolee sul motore

Termostatazionesulle valvole

e funzionamentocontinuo del motore

10Tasto

IAQ/Resistenzaabilitata

TastoIAQ/Resistenza

disabilitata

Abilitazionedel DIP 8

DIP 8non abilitato

DIP1

ONThermostatic

control of the motor

OFFThermostatic

control of the valves

2Thermostatic

control of 1 valve (2-tube installation)

Thermostaticcontrol of 2 valves (4-tube installation)

3TME minimum

electronic sensorpresent

Seasonal switchingfrom

control unit button

TME minimumelectronic sensor

not present

4 Remoteseasonal switching

CRYSTALLelectronic air filter

present5

Complementaryelectrical resistor

present

4-tube installations,automatic togglingbetween heating

and coolingwith dead zone

6Without

automaticseasonal togglingwith intermediate

dead zone

Variation of nighttime set point(-3°C winter,

+3°C summer)8 Disabling of

fan coil operation

DIP 8enabled7 DIP 8

not enabled

9Temperature control

on the valvesand the motor

Temperature controlon the valves

and the continuousmotor speed

10 IAQ/Heater buttonenabled

IAQ/Heater buttondisabled

8

7

DIP1

ONTermorégulation

sur le moteur

OFFTermorégulationsur les vannes

2Termorégulationsur une vanne

(installationà 2 tubes)

Termorégulationsur deux vannes

(installationà 4 tubes)

3Présence de la sondede temp. minimaleélectronique TME

Commutationsaisonnière

à l’aide du boutonde l’unité

Absence de la sondede temp. minimaleélectronique TME

4Commutationsaisonnièreà distance

Présencede filtre air

électronique“CRYSTALL”

5Présence

de résistanceélectrique

complémentaire

Installationsà 4 tubes, passageautomatique entre

chauffage etrafraîchissement,

et vice versa,avec zone morte

6Sans changement

automatiquesaisonnier,

avec zone morteintermédiare

Modification de latemperature nuit

(-3°C hiver,+3°C été)

Exclusionde fonctionnement

duventilo-convecteur

Activationdu DIP 8

DIP 8non activé

9Regulation

par thermostatsur les vanneset sur le moteur

Regulation parthermostat sur lesvannes et vitesse

continue du moteur

10Touche

IAQ/Résistanceactivée

ToucheIAQ/Résistance

deactivée

8

7

DIP1

ONTermostatsteuerung

am Motor

OFFTermostatsteuerung

an den Ventilen

2Termostatsteuerung

an einem Ventil(2-Leiter-System)

Termostatsteuerungan zwei Ventilen

(4-Leiter-System)

3Präsenz

der elektronischenMindestsonde TME

SaisonaleUmschaltungüber die Taste

der Einheit

Fehelnder elektronischenMindestsonde TME

4 SaisonaleFern-Umschaltung

Präsenzdes elektronischen

Luftfilters“CRYSTALL”

5 PräsenzZusatz-Heizregister

4-Leiter-System,automatischer

Wechselvon Heizungzu Kühlung

und umgekehrt,mit Todbereich

6Ohne

automatischenSaisonwechsel,mit Zwischen-

Todbereich

Veränderung derNachteinstellung

(-3°C Winter,+3°C Sommer)

Ausschlussder Funktion des

Lüftungskonvektors

Freigabedes DIP 8

DIP 8nicht freigegeben

9Thermostatsteuerung

and den Ventilenund am Motor

Thermostatatisierungan den Ventilen

und gleich bleibendeMotor drehzahl

10 IAQ-Taste/Heizung IAQ-Taste/Heizunggesperrt

8

7

DIP1

ONTermostatación

en el motor

OFFTermostataciónen las válvulas

2Termostataciónen una válvula

(instalacióncon 2 tubos)

Termostataciónen dos válvulas

(instalacióncon 4 tubos)

3Presencia de la

sonda de mínimaelectrónica TME

Conmutaciónestacional

en el pulsadorde la unidad

Ausencia de lasonda de mínimaelectrónica TME

4 Conmutaciónestacional remota

Presenciade filtro

de aire electrónico“CRYSTALL”

5Presencia

de resistenciaeléctrica

complementaria

Instalacióncon 4 tubos,

paso automáticodel calentamiento

al enfriamietoy viceversa,

con zona muerta

6Sin

cambio automáticoestacional,

con zona muertaintermedia

Variacióndel Set nocturno(-3°C invierno,+3°C verano)

Exclusiónde funcionamiento

del fan coil

DIP 8en servicio

DIP 8fuera de servicio

9Termostataciónen las válvulasy en el motor

Termostataciónen las válvulas

y velocidadcontinua del motor

10Tecla

IAQ/Resistenciaen servicio

TeclaIAQ/Resistenciafuera de servicio

8

7

DIP1

ONThermostatischeregeling motor

OFFThermostatischeregeling kleppen

2Thermostatische

regeling van 1klep (installatiemet 2 leidingen)

Thermostatischeregeling van tweekleppen (installatie

met 4 leidingen)

3Aanwezigheid

van deTME-sonde

Seizoen-somschakeling

met de knoppenvan de eenheid

Afwezigheidvan de

TME-sonde

4Seizoen-

somschakelingop afstand

Aanwezigheidelektronische

luchtfilter“CRYSTALL”

5Aanwezigheid

bijkomendeelektronische

weerstand

Installatiemet 4 leidingen,automatischeomschakeling

van verwarmingop afkoeling

en omgekeerd,met dode zone

6

Afwezigheid vande automatische

Seizoen-somschakeling,

met dodetussenzone

Veranderingnachtelijke Set

(-3°C in de winter,+3°C in de zomer)

Uitsluiting werkingventilator-convector

Dimschakelaar8 geactiveerd

Dimschakelaar8 niet geactiveerd

9Temperatur

regeling op motoren regelkranen

Temperatur regeling opmotor en regelkranenmet constante motor

werking

10 IAQ-VerwarmingsKnop-beschikbaar

IAQ-VerwarmingsKnop-onbeschikbaar

Type Code

TMO-DI 9060165

Questo comandoè composto da due unità:

• Unità di controllo, con pulsan- tiera e display, da installare sulla parete del locale da climatizza- re, sporgente oppure semincas- sata nel vano interruttori.

• Unità di potenza fissata a bordo del ventilconvettore.

- Il comando a parete deve essere collegato con due fili (12V DC) all’unità di potenza; lunghezza massima del collegamento: 30m.

- Il comando a perete contiene la sonda per la lettura della tempe- ratura amiente, pertanto deve essere posizionato a circa 1,5 m di altezza e lontano da fonti di calore e da correnti d’aria fredda.

- Nell’unità da parete è inserito un DIP-SWITCH a 10 poli che deb- bono essere posizionati secon- do le esigenze per ottenere dal comando le funzioni desiderate:

This controlconsists of two units:

• Control unit with keypad and display for wall installation in the room to be air conditioned, projecting or semi-flush mounted in the switch recess.

• Power unit mounted on the fan coil.

- The wall unit must be connected to the power unit with two wires (12 V DC), maximum length of connection: 30 m.

- The wall unit contains a sensor for monitoring room temperature and must therefore be positioned at a height of about 1.5 metres, away from heat sources and currents of cold air.

- The wall unit has a ten pole DIP switch which must be set according to the required functions:

Cette commandeest constituée par deux unités:

• Unité de contrôle, avec panneau de commande et afficheur, à installer sur la paroi du local à climatiser, en saillie ou semi- encastrée dans une boîte pour interrupteurs.• Unité de puissance fixée sur le ventilo-convecteur.

- La commande murale doit être raccordée à l’unité de puissance avec deux conducteurs (12V DC); longueur maxi du raccordement 30 m.

- La commande murale contient la sonde pour la lecture de la température ambiante et doit par conséquent être placée à environ 1,5 m de hauteur et loin de toute source de chaleur ou de courants d’air froid.- Dans l’unité murale se trouve un DIP switch à 10 pôles qui doivent être positionnés selon les exigences de manière à ce que la commande fournisse les fonctions souhaitées:

Diese Steuerungbesteht aus zwei Einheiten:

• Kontrolleinheit mit Bedienfeld und Display, zur Installation an der Wand des Raumes, der klimatisiert werden soll. Die Installation ist sowohl auf Putz oder halbeingebaut im Schalterbord möglich.• Am Gebläsekonvektor befestigte Leistungseinheit.

- Die an der Wand installierte Steuerung muss mit zwei Drähten (12V DC) an der Leistungseinheit angeschlossen werden; diese Verbindung darf nicht länger als max. 30 m sein.- Die an der Wand installierte Steuerung enthält die Sonde, an der die Raumtemperatur abgelesen werden kann, deshalb muss sie in etwa 1,5 m Höhe und fern von Wärmequellen und Zugluft angebracht werden.- In der Wandeinheit befinden sich 10 DIP-Schalter, die je nach den spezifischen Anforderungen positioniert werden müssen, um von der Steuerung die gewünschten Funktionen zu erhalten:

Este controlse compone de dos unidades:

• Unidad de control con botonera y display a instalar en la pared del cuarto a climatizar, saliente o semi-empotrada en hueco para interruptores.

• Unidad de potencia colocada a bordo del fan coil.

- El control de pared se puede co- nectar, mediante dos hilos (12V DC), a la unidad de potencia; longitud máxima del enlace 30 metros.

- El control de pared contiene la sonda para la lectura de la tem- peratura ambiente, por lo tanto es preciso colocarlo a aproxima- damente 1,5 metros de altura y lejos de fuentes de calor y de corrientes de aire frío.- En la unidad de pared hay un DIP SWITCH con 10 polos que es preciso configurar según las exigencias a fin de conseguir que el control realice las funciones deseadas:

Deze bedieningbestaat uit twee onderdelen:

• Controleonderdeel met knopbord en display, te installeren op de muur van het lokaal dat moet worden verwarmd/afgekoeld, of gedeeltelijk in de wand gepast in de schakelaarsruimte.• Vermogenseenheid, aangebracht op de ventilatorconvector.

- De muurbediening moet verbonden worden met de vermogenseenheid d.m.v. twee draden (12V DC); maximumlengte van de verbinding: 30 m.

- De muurbediening bevat de sonde voor de lezing van de kamer- temperatuur, hij moet dus op een hoogte van 1,5m geplaatst worden en ver van warmtebronnen en koude luchtstromingen.

- In de muurbediening is ook een 10-polige dimschakelaar ingelast, die geplaatst moet worden volgens behoefte om de mogelijke functies te verkrijgen:

COMANDOAUTOMATICO

CON TERMOSTATOELETTRONICO

AUTOMATICCONTROL

WITH ELECTRONICTHERMOSTAT

COMMANDEAUTOMATIQUE

AVEC THERMOSTATÉLECTRONIQUE

STEUERUNGAUTOMATIKBETRIEB

MIT ELEKTRONISCHEMTHERMOSTAT

CONTROLAUTOMÁTICO

CON TERMOSTATOELECTRÓNICO

AUTOMATISCHEBEDIENING

MET ELEKTRONISCHETHERMOSTAAT

33 33A

TMO-DI – Cod. 9060165 TMO-DI – Code 9060165 TMO-DI – Code 9060165 TMO-DI – Art. Nr. 9060165 TMO-DI – Cód. 9060165 TMO-DI – Code 9060165

Page 34:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

SCHEMI ELETTRICI:vedi pag. 36

WIRING DIAGRAMS:see page 36

SCHEMAS ELECTRIQUES:cf. p. 36

SCHALTPLÄNE:siehe Seite 36

ESQUEMAS ELÉCTRICOS:ver pág. 36

ELEKTRISCHE SCHEMA’S:zie pag. 36

34 34A

- L’unità di potenza è fornita di in- gressi e uscite su morsetti e deve essere alimentata con corrente monofase 230V 50Hz.- L’unità di potenza supporta le seguenti funzioni:

• Controllo con cambio automatico della velocità del ventilatore.

• Controllo ON-OFF della/e val- vola/e acqua.• Controllo filtro elettrostatico, o re- sistenza elettrica complementare.

• Ingresso per eventuale cambio stagionale (E/I) remoto.

• Ingresso per eventuale segnale di variazione (+/-3°C) o esclusione.

- Negli impianti a 4 tubi corredati di valvole, con presenza costan- te dei fluidi di alimentazione, esi- ste la possibilità di passare auto- maticamente dalla fase riscaldan- te a quella raffrescante (o vice- versa) in base allo scostamento della temperatura ambiente ri- spetto a quella fissata con il ter- mostato, con zona morta inter- media di 2°C.

- The power unit has input and output terminals and must be powered with a single phase 230V 50Hz current.- The power unit supports the following functions:

• Control of fan speed with automatic switchover.

• ON/OFF control of water valve(s).

• Control of electrostatic filter or supplementary electric heater.

• Input for optional remote seasonal switchover (SUM/WIN).

• Input for optional variation (+/-3°C) or exclusion signal.

- In four-tube installations with valves and constant presence of fluid in the circuits, switching between the heating and cooling phase (and vice versa) can be automatic, according to the difference between room tempe- rature and the temperature set on the thermostat, with an intermediate dead zone of 2°C.

- L’unité de puissance et dotée d’entrées et de sorties sur des bornes et doit être alimentée avec un courant monophasé 230V 50Hz.- L’unité de puissance supporte les fonctions suivantes:

• Contrôle avec changement auto- matique de la vitesse ventilateur.

• Contrôle ON-OFF de la ou des vannes eau.• Contrôle filtre électrostatique, ou résistance électrique complé- mentaire.• Entrée pour éventuel changement de saison (E/H) à distance.

• Entrée pour éventuel signal de variation (± 3°C) ou désactivation.

- Dans les installations à 4 tuyau- teries équipées de vannes, avec présence constante des fluides d’alimentation, on a la possibilité de passer automatiquement de la phase de chauffage à celle de rafraîchissement (et vice versa) sur la base de l’écart entre la température ambiante et celle réglée sur le thermostat, avec une zone morte intermédiaire de 2°C.

- Die Leistungseinheit besitzt Ein- und Ausgänge an Klemmen und muss mit einphasigem Strom 230V 50Hz versorgt werden.- Die Leistungseinheit hat folgende Funktionen:

• Steuerung mit automatischem Wechsel der Drehzahlstufe des Ventilators.• ON-/OFF-Steuerung des Ventils bzw. der Ventile.• Steuerung des elektrostatischen Filters bzw. des zusätzlichen elektrischen Heizwiderstands.• Eingang für den eventuellen ferngesteuerten Betriebsarten- wechsel S/W.• Eingang für das eventuelle Änderungs- (+/-3°C) oder Aus- schlusssignal.

- Bei den mit Ventilen ausgestatteten Anlagen mit 4 Rohren mit konstanter Präsenz der Versorgungsflüssig- keiten, ist die Möglichkeit gegeben, je nach der Abweichung der Raumtemperatur im Vergleich zu der am Thermostat eingegebenen Temperatur automatisch von der Heiz- zur Kühlphase (und umge- kehrt) überzugehen, mit einem Übergangs-Totbereich von 2°C.

- La unidad de potencia viene pro- vista de entradas y salidas en bor- nes y es preciso alimentarla con corriente monofásica de 230V 50Hz.- La unidad de potencia respalda las funciones siguientes:

• Control con cambio automático de la velocidad del ventilador.

• Control ON-OFF de la/s válvula/s del agua.• Control filtro electrostático, o resi- stencia eléctrica complementaria.

• Entrada para eventual cambio de temporada (VER-INV) a distancia.

• Entrada para eventual señal de variación (+/-3°C) o exclusión.

- En las instalaciones con 4 tubos provistos de válvulas, con pre- sencia constante de los fluidos de alimentación, cabe la posibi- lidad de pasar automáticamente desde la fase calefactora a la refrescadora (y viceversa) según la diferencia entre la tempera- tura ambiente y la determinada con el termostato; con zona muer- ta intermedia de 2°C.

- De vermogenseenheid is voorzien van in- en uitgangen op klemmen en moet gevoed worden met een- fasige lijn 230V 50Hz.- De vermogenseenheid is voorzien van de volgende functies:

• Controle met automatische wisseling van de snelheid van de ventilator.• Controle ON-OFF van de water- klep(pen).• Controle elektrostatische filter, of bijkomende elektrische weerstand.

• Ingang voor eventuele seizoen- wisseling (Z/W) met afstands- bediening.• Ingang voor eventueel signaal van wijziging (+/3°C) of uitsluiting.

- In de installaties met 4 leidingen voorzien van kleppen, met constante aanwezigheid van vloeistoffen, is het mogelijk om automatisch over te schakelen van de verwarmnaar de afkoelfase (of omgekeerd) in functie van de deviatie tussen de kamertemperatuur en de ingestelde temperatuur, met dode tussenzone van 2°C.

Page 35:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

35 35A

Per controllare più ventilconvettori(max. 10) da una unica unità, è suf-ficiente che gli apparecchi, esclusoil primo, siano corredati di una unitàdenominata ripetitore collegata incascata con tre soli fili di sezione0,5 mm2; la connessione tra l’unitàdi potenza ed il ripetitore è a 12 V.d.cpiù GND; sui cavi avviene la trasmis-sione in frequenza dei dati, quindifare attenzione che i fili di collega-mento non siano nella stessa cana-lina dei fili di potenza; i led presentisulla morsettiera indicano lo statodi funzionamento.

Schema di collegamento(Fig.1)

A: FAN-COIL(unico o primo di una serie)

collegatoal comando a parete TMO-DI

tramite l’unità di potenzaper TMO-DI.

B: FAN-COILcollegati allo stesso comando

del primo Venticonvettoretramite

un collegamento a cascatatra RIPETITORI PER TMO-DI.

To control a number of fan coils(max.10) from a single unit, all theunits except the first must be fittedwith a repeater unit and connectedin a cascade with three 0,5 mm2

wires. The connection between thepower unit and repeater is 12 V DCplus earth and the wires are alsoused for the frequency transmissionof data. Care should therefore betaken to ensure that the connectionwires do not run in the same channelas the power wires. The LEDs onthe terminal board indicate operatingstatus.

Wiring diagram(Fig.1)

A: FAN COIL(single or first in a series)

connectedto the TMO-DI wall control unit

via the TMO-DI power unit.

B: FAN COILconnected to the control unit

of the first fan coilby means

of a cascade connectionvia REPEATER FOR TMO-DI.

Pour contrôler plusieurs ventilo-convecteurs (max.10) à partir d’uneseule unité, il est suffisant que lesappareils, à l’exception du premier,soient munis d’une unité appeléerépétiteur reliée en cascade avecseulement trois fils de section 0,5mm2; la connexion entre l’unité depuissance et le répétiteur est à 12Vdcplus terre GND et la transmissionen fréquence des donnés a lieu surles câbles, donc faire attention queles fils de connexion ne soient pasdans la même gaine que les filsde puissance; les leds présentessur le bornier indiquent l’état defonctionnement.

Schéma de connexion(Fig.1)

A: FAN-COIL(unique ou premier d’une série)

relié à la commande TMO-DIpar l’intermédiaire

de l’unité de puissancepour TMO-DI.

B: FAN-COILreliés à la même commande

que le premier ventilo-convecteurpar une connexionen cascade entre

RÉPÉTITEURS POUR TMO-DI.

Um über nur eine Einheit mehrereLüftungskonvektoren (max.10) zusteuern müssen die Geräte lediglich– nach Ausschluss des ersten –mit einem kaskadengeschaltetenMehrfach-Steuerrelais mit derBezeichnung ausgestattet werden,der mit nur drei Drähten mit Querschnitt0,5 mm2 angeschlossen wird; dieVerbindung zwischen Netzteil undMehrfach-Steuerrelais ist 12 V d.c.plus GND, und über die Kabel erfolgtdie Übertragung der Daten, undfolglich muss bei allen Mehrfach-Steuerrelais darauf geachtet werden,dass die Anschlussdrähte nicht inderselben Kabelführung verlaufen,wie die Leistungsdrähte; die an derKlemmleiste vorhandenen LED’szeigen den Funktionsstatus an.

Anschlussschaltplan(Fig.1)

A: FAN-COIL(allein oder als erster einer Serie)

über das Netzteil der TMO-DIan die Wandsteuerung TMO-DI

angeschlossen.

B: FAN-COILmittels Kaskadenschaltung

zwischen MEHRFACH-STEUERRELAIS FÜR TMO-DI

an dieselbe Steuerung wieder erste Lüftungskonvektor

angeschlossen.

Para controlar más fan coils (max.10) con una única unidad, bastacon que los aparatos, excluido elprimero, estén equipados con unaunidad denominada repetidor co-nectada en cascada con sólo treshilos de sección 0,5 mm2; la co-nexión entre la unidad de poten-cia y los repetidores es a 12 V.c.c.más GND; en los cables tiene lugarla transmisión en frecuencia de losdatos, por lo tanto se tiene quevigilar que los hilos de conexiónno estén en el mismo camino quelos hilos de potencia; los led pre-sentes en la caja de bornes indi-can el estado de funcionamiento.

Esquema de conexión(Fig.1)

A: FANCOIL(único o primero de una serie)

conectadoal mando de pared TMO-DI

mediante la unidad de potenciapara TMO-DI.

B: FANCOILconectados al mismo mando

que el primer fan coilmediante una conexión

en cascada entreREPETIDORES PARA TMO-DI.

Om meerdere ventilatorconvectorste controleren (max. 10) vanuit éénenkele bediening, is het voldoendedat de apparaten, het eerste uit-gesloten, voorzien zijn van eeneenheid, repeater genoemd enverbonden in cascade met enkeldrie draden met een doorsnedevan 0,5 mm2; de verbinding tussende vermogenseenheden en derepeater is op 12V.d.c. plus GND;op de kabels gebeurt de transmissieop frequentie van de gegevens.Men moet er dus op letten dat deverbindingsdraden niet in detzelfdeleiding zitten als de vermogenbinding;de leds aanwezig op het klemmen-bord duiden het functioneren aan.

Verbindingsschema(Fig.1)

A: ventilatorconvector(enige en eerste van een reeks)

verbondenmet de muurbediening TMO-DId.m.v. de vermogenseenheid

voor TMO-DI.

B: ventilatorconvectorverbonden met dezelfdebediening als de eerste

ventilatorconvector d.m.v. eencascadeverbinding tussen

repeaters.

RIPETITORE PERTMO-DI

REPEATER FORTMO-DI

REPETITEUR POURTMO-DI

MEHRFACH-STEVERRELAISFÜR TMO-DI

REPETIDOR PARATMO-DI

VERSTERKER VOORTMO-DI

SEL-DI – Cod. 9060139 SEL-DI – Code 9060139 SEL-DI – Code 9060139 SEL-DI – Art. Nr. 9060139 SEL-DI – Cód. 9060139 SEL-DI – Code 9060139

SCHEMI ELETTRICI:vedi pag. 36A

WIRING DIAGRAMS:see page 36A

SCHEMAS ELECTRIQUES:cf. p. 36A

SCHALTPLÄNE:siehe Seite 36A

ESQUEMAS ELÉCTRICOS:ver pág. 36A

ELEKTRISCHE SCHEMA’S:zie pag. 36A

Fig. 1

Page 36:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

36 36A

Type Code

TMO-DI 9060165

Type Code

SEL-DI 9060139

Ripetitore per TMO-DIRepeater for TMO-DIRepetiteur pour TMO-DIMehrfach-Steverrelais für TMO-DIRepetidor para TMO-DIVersterker voor TMO-DI

R

Unità di potenza per TMO-DIPower unit for TMO-DIUnité de puissance pour TMO-DILeistungseinheit für TMO-DIUnidad de potencia para TMO-DIVermogenseenheid voor TMO-DI

P

Unità di potenza per TMO-DIPower unit for TMO-DIUnité de puissance pour TMO-DILeistungseinheit für TMO-DIUnidad de potencia para TMO-DIVermogenseenheid voor TMO-DI

P

Page 37:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

MFCNLPE 1310 12 1411 157 9854 6

M230V50Hz

OG

BK

RD

BUB

U

BK

GN

YE

MC87654321

PE

L N

Q1

230Vac50Hz

9

Dopo aver scelto le funzioni desi-derate, montare il comando a paretefacendo attenzione a posizionarlosulla parete del locale da condizio-nare all’altezza di circa 1,5m, su unaparete intermedia e lontano da fontidi calore e da correnti d’aria fredda;collegare la morsettiera posta sullascheda elettronica alla morsettieraposta sulla fiancata del ventilcon-vettore secondo lo schema selezio-nato e nel rispetto degli schemielettrici.

Per il collegamento tra termostatoe ventilconvettore utilizzare condut-tori con sezione minima 0,75 mm2.

Il comando può gestire le seguentifunzioni:

- Accensione e spegnimento del ventilconvettore.

- Impostazione della temperatura ambiente desiderata (SET).

- Possibilità di selezionare il ciclo di funzionamento estivo o invernale direttamente dalla pulsantiera del comando.

- Selezione manuale delle tre velo- cità del ventilatore.

- Selezione automatica delle tre ve- locità del ventilatore in funzione dello scostamento esistente fra la temperatura impostata come set e quella ambiente.

La eventuale sonda di minima ac-qua TME deve essere collegata allamorsettiera.

Collegando la sonda di minima(accessorio TME posta tra le alettedella batteria di scambio termico),nel solo ciclo invernale, il ventila-tore entrerà in funzione solamentese la temperatura dell’acqua è su-periore a 42°C e verrà fermatoquando quest’ultima è inferiore a38°C.

After choosing the required functions,mount the control unit to the wall,taking care to position it on an innerwall in the room being air-conditionedat a height of about 1.5 m, away fromsources of heat and currents of coldair. Connect terminal board on theelectronic board to the terminalboard located on the side of the fancoil, according to the selected layoutand following the wiring diagrams.

For the connection between thethermostat and the fan coil, use cableswith a minimum cross-section of0.75 mm2.

The control unit can manage thefollowing functions:

- Turning the fan coil on and off.

- Setting and reading the required room temperature (SET).

- Selecting the summer or winter operating cycle directly from the control keypad.

- Manual selection of the three fan speeds.

- Automatic selection of the three fan speeds according to the difference between the set temperature and the room temperature.

Any TME minimum water probemust be connected to terminalboard.

In the winter cycle only, if a minimumsensor is connected (TME accessorylocated between the fins of the heatexchange coil), the fan coil will startup only if the water temperature risesabove 42°C and shut down whenwater temperature drops below 38°C.

Après avoir choisi les fonctions vou-lues, monter la commande muraleen veillant à la placer sur le mur dulocal à conditionner à une hauteurde 1,5 m environ, sur une cloisonet loin de sources de chaleur et decourants d’air froid; connecter lebornier placé sur la carte électro-nique au bornier placé sur le flancdu ventilo-convecteur selon le sché-ma sélectionné et en respectantles schémas électriques.

Pour la connexion entre thermostatet ventilo-convecteur utiliser des câ-bles de section minimum 0,75 mm2.

La commande peut gérer les fonc-tions suivantes:

- Mise en marche et arrêt du ventilo- convecteur.

- Programmation de la température ambiante voulue (SET).

- Possibilité de sélectionner le cycle de fonctionnement été ou hiver directement à partir du tableau de commande.

- Sélection manuelle des trois vites- ses du ventilateur.

- Sélection automatique des trois vitesses du ventilateur en fonction de l’écart existant entre la tempé- rature programmée et la tempéra- ture ambiante.

Si on installe une sonde de tempé-rature minimale eau TME, elle doitêtre raccordée au bornier.

En connectant la sonde de tempé-rature minimale (accessoire TMEplacée entre les ailettes de la bat-terie d’échange thermique), encycle hiver seulement, le ventila-teur ne se mettra en marche quesi la température de l’eau est supé-rieure à 42°C et s’arrêtera quandcelle-ci est inférieure à 38°C.

Nachdem die gewünschten Funktioneneingestellt wurden, das Steuergerätan einer Innenwand in einer Höhevon zirka 1,5 m und fern von Wärme-quellen und Kaltluftströmen montieren;die Klemmleiste an der Elektronik-platine gemäß des gewähltenSchemas und unter Einhaltung derSchaltpläne mit der Klemmleiste ander Seite des Lüftungskonvektorsverbinden.

Für die Verbindung zwischen Thermostatund Lüftungskonvektor Drähte miteinem Querschnitt von min. 0,75 mm2

benutzen.

Das Steuergerät kann die folgendenFunktionen verwalten:

- Ein- und Ausschalten des Lüftungs- konvektors.

- Einstellung der gewünschten Raum- temperatur (SET).

- Möglichkeit des Einstellens von Sommer- oder Winterbetrieb direkt an der Schalttafel oder.

- Manuelle Einstellung der drei Ventilatordrehzahlen.

- Automatische Einstellung der drei Ventilatordrehzahlen entsprechend der Abweichung zwischen eingestellter Set Temperatur und der effektiven Raumtemperatur.

Die eventuelle MindesstandsondeTME wird an die Klemmleisteangeschlossen.

Durch Anschließen der Mindest-sonde (Zubehör TME zwischenden Lamellen des Wärmetauscher-registers, wird der Ventilator nureingeschaltet, wenn die Wasser-temperatur über 42°C beträgt, undausgeschaltet, wenn sie bis unter38°C absinkt.

Después de haber elegido las fun-ciones deseadas, montar el mandode pared poniendo atención en colo-carlo en la pared del local a acondi-cionar a una altura de 1,5 m aproxi-madamente, en un tabique y lejos delas fuentes de calor y de las corrientesde aire frío; conectar la caja de bornessituada sobre la tarjeta electrónicaa la caja de bornes situada en ellado del ventilador convector según elesquema seleccionado y respetandolos esquemas eléctricos.

Para la conexión entre el termostatoy el ventilador convector usar cablescon una sección mínim de 0,75 mm2.

El mando puede gestionar las si-guientes funciones:

- Encendido y apagado del venti- lador convector.

- Introducción de la temperatura ambiente deseada (SET).

- Posibilidad de seleccionar el ciclo de funcionamiento verano o invierno directamente desde el teclado del mando.

- Selección manual de las tres velo- cidades del ventilador.

- Selección automática de las tres velocidades del ventilador en fun- ción de la diferencia existente entre la temperatura introducida como set y la temperatura ambiente.

La eventual sonda de mínima aguaTME se tiene que conectar a la cajade bornes.

Conectando la sonda de mínima(accesorio TME situado entre lasaletas de la batería de cambio tér-mico), en el ciclo invernal, el venti-lador entrará en función únicamentesi la temperatura del agua es supe-rior a 42°C y se cerrará cuandoesta última sea inferior a 38°C.

Na de keuze van de gewenste functies,wordt de bediening gemonteerd aande muur. Voor een correcte werking,moet de bediening van de thermostaatworden geplaatst aan de wand van hetlokaal dat moet worden verwarmd/afgeloed, op een hoogte van circa 1,5meter en ver verwijderd van warm-tebronnen en koude luchtstromen; sluithet klemmenbord op de elektronischefiche aan op het klemmenbord op dezijkant van de ventilator-convector,overeenkomstig het geselecteerdschema en de schakelschema’s.

Voor de verbinding tussen de ther-mostaat en de ventilator-convector,gebruik draden met een minimaledoorsnede van 0,75 mm2.

De bediening kan de volgendefuncties beheren:

- In- en uitschakelen van de ventilator- convector.

- Instelling van de gewenste omgevings- temperatuur (SET).

- De mogelijkheid de winter- of zomer- cyclus te kiezen rechtstreeks met de knoppen van de bediening of.

- Manuele selectie van drie snelheden voor de ventilator.

- Automatische selectie van de drie snelheden voor de ventilator, in functie van het bestaand verschil tussen de ingestelde temperatuur (SET) en de omgevingstemperatuur.

De eventuele uitschakelthermostaatTME moet aangesloten zijn op hetklemmenbord.

Wanneer de uitschakelthermostaatin de wintercyclus (accessoire TMEtussen de polen van de batterij voorde warmtewisseling), treedt deventilator alleen in werking wanneerde temperatuur van het water 42°Coverschrijdt en schakelt uit wanneerde temperatuur van het water onder38°C zakt.

37 37A

Type Code

TMO-503-S 9060171 COMANDO ELETTRICOCON TERMOSTATO

ELETTRONICO

ELECTRIC CONTROL UNITWITH ELECTRONIC

THERMOSTAT

COMMANDE ELECTRIQUEAVEC THERMOSTAT

ELECTRONIQUE

ELEKTRISCHE STEUERUNGMIT ELEKTRONISCHEM

THERMOSTAT

CONTROL ELÉCTRICOCON TERMOSTATO

ELECTRÓNICO

ELEKTRISCHE BEDIENINGMET ELEKTRONISCHE

THERMOSTAAT

TMO-503-SCod. 9060171

TMO-503-SCode 9060171

TMO-503-SCode 9060171

TMO-503-SArt. Nr. 9060171

TMO-503-SCód. 9060171

TMO-503-SCode 9060171

A

Page 38:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

12345678

MC

MIN

MAX

MED

9

NLPE 1310 12 1411 157 9854 6

M230V50Hz

230Vac50Hz

7632 84 1151 12109

MFC

MC

OG

BK

RD

BUB

U

BK

GN

YE

Q1

N L

PE BU B

U

OG

BN RD

BK

BK

OG

RD

RD

OG

BK

BN

M

BU

BK

8 9

5

BK

BU

OG

10

BU

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

OG

7

75

BK

PE 14

3

NL 15

11

BN

134

6

RD

MFC

L N

Q1

230Vac50Hz

PE PE

230Vac50Hz

Q1

N L

MFC

RD

6

4 13

BN

11

15L N

3

14PE

BK

5 7

7

OG

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BU

10

OG

BU

BK

5

98

BK

BU

M

TMO-503-S

12345678

MC

MIN

MAX

MED

9

NLPE 1310 12 1411 157 9854 6

M230V 50Hz

230Vac50Hz

7632 84 1151 12109

MFC

MC

OG

BK

RD

BUB

U

BK

GN

YE

Q1

N L

PE

41 2 53

BU B

U

OG

BN RD

BK

BN

BK

OG

RD

RD

OG

BK

BN

BN

M

BU

BK

8 9

5

5

BK

BU

OG

10

BU

BN

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

2

OG

7

75

BK

BN

PE 14

3

1

NL 15

11

BN

134

6

43

RD

MFC

L N

Q1

230Vac50Hz

PE PE

230Vac50Hz

Q1

N L

MFC

RD

3 4

6

4 13

BN

11

15L N

1

3

14PE

BN

BK

5 7

7

OG

2

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BN

BU

10

OG

BU

BK

5

5

98

BK

BU

M

TMO-503-S

Type Code

SEL-CB 9066304

Type Code

SEL-CR 9066311

38 38A

Applicato sulla strutturadei ventilconvettori, consenteil controllo di più apparecchi

(Max 8)su segnale di un unico

comando remoto.

Fitted to the frameof the fan coil, this enables

up to eight unitsto be cotrolled by the signal

from a singleremote control unit.

Appliqué sur la structuredes ventilo-convecteurs, permet

de contrôlerplusieurs appareils (8 maxi)

sur signal d’uneseule commande à distance.

Diese Vorrichtung wird an derStruktur der Gebläsekonvektoren

angebracht und gestattetdie Steuerung meherer (max. 8)

Geräte mit dem Signaleiner einzigen Fernbedienung.

Aplicado en la structurade los fan coils

permite controlar variosaparatos (como máximo 8)

mediante la señalde un único mando a distancia.

Gemonteerd op de structuurvan de ventilatorconvectors,

voor de bediening van meerdereapparaten (max 8) via

een signaal afkomstig van éénenkele afstandsbediening.

SELETTOREDI VELOCITÀ RICEVENTE

SPEED SELECTORRECEIVER

SELECTEURDE VITESSE RECEPTEUR

DREHZAHLWÄHLSCHALTEREMPFÄNGER

SELECTORDE VELOCIDAD RECEPTOR

SNELHEIDSSCHAKELAARONTVANGER

TMO-503-S conSEL-CB – Cod. 9066304

(MV - MVB)

TMO-503-S withSEL-CB – Code 9066304

(MV - MVB)

TMO-503-S avecSEL-CB – Code 9066304

(MV - MVB)

TMO-503-S mitSEL-CB – Art. Nr. 9066304

(MV - MVB)

TMO-503-S conSEL-CB – Cód. 9066304

(MV - MVB)

TMO-503-S metSEL-CB – Code 9066304

(MV - MVB)

SEL-CR – Cod. 9066311

(MO - IV - IO)SEL-CR – Code 9066311

(MO - IV - IO)SEL-CR – Code 9066311

(MO - IV - IO)SEL-CR – Art. Nr. 9066311

(MO - IV - IO)SEL-CR – Cód. 9066311

(MO - IV - IO)SEL-CR – Code 9066311

(MO - IV - IO)

senza valvole - without valvessans vannes - Ohne ventile

sin válvulas - Zonder kleppen

senza valvole - without valvessans vannes - Ohne ventile

sin válvulas - Zonder kleppen

Page 39:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

MFC

230Vac50Hz

Q1

N L

PE

GN

YE

BK

BU

BU

RD BK

OG

50Hz230VM

64 5 8 97 1511 141210 13PE L N

E

98542 MC631 7 10

MFC

230Vac50Hz

Q1

N L

PE

GN

YE

BK BU

BU

RD BK

OG

50Hz230VM

64 5 8 97 1511 141210 13PE L N

E1

E2

8 1041 3 975 MC62

B

C

Dopo aver scelto le funzioni desi-derate, montare il comando a paretefacendo attenzione a posizionarlosulla parete del locale da condizio-nare all’altezza di circa 1,5m, su unaparete intermedia e lontano da fontidi calore e da correnti d’aria fredda;collegare la morsettiera posta sullascheda elettronica alla morsettieraposta sulla fiancata del ventilcon-vettore secondo lo schema selezio-nato e nel rispetto degli schemielettrici.

Per il collegamento tra termostatoe ventilconvettore utilizzare condut-tori con sezione minima 0,75 mm2.

Il comando può gestire le seguentifunzioni:

- Accensione e spegnimento del ventilconvettore.

- Impostazione della temperatura ambiente desiderata (SET).

- Possibilità di selezionare il ciclo di funzionamento estivo o invernale direttamente dalla pulsantiera del comando.

- Selezione manuale delle tre velo- cità del ventilatore.

- Selezione automatica delle tre ve- locità del ventilatore in funzione dello scostamento esistente fra la temperatura impostata come set e quella ambiente.

- Termostatazione contemporanea delle valvole e del ventilatore.

- Termostatazione sulle valvole e funzionamento continuo del ven- tilatore.

- Termostatazione sulle valvole, per impianti a 4 tubi, con commuta- zione automatica Estate/Inverno in funzione della temperatura aria, con zona morta di 2°C.

Idoneo per il controllo termostatico(ON-OFF) della/e valvola/e acqua.

La eventuale sonda di minima ac-qua TME deve essere collegata allamorsettiera.

Collegando la sonda di minima(accessorio TME posta tra le alettedella batteria di scambio termico),nel solo ciclo invernale, il ventila-tore entrerà in funzione solamentese la temperatura dell’acqua è su-periore a 42°C e verrà fermatoquando quest’ultima è inferiore a38°C.

After choosing the required functions,mount the control unit to the wall,taking care to position it on an innerwall in the room being air-conditionedat a height of about 1.5 m, away fromsources of heat and currents of coldair. Connect terminal board on theelectronic board to the terminalboard located on the side of the fancoil, according to the selected layoutand following the wiring diagrams.

For the connection between thethermostat and the fan coil, use cableswith a minimum cross-section of0.75 mm2.

The control unit can manage thefollowing functions:

- Turning the fan coil on and off.

- Setting and reading the required room temperature (SET).

- Selecting the summer or winter operating cycle directly from the control keypad.

- Manual selection of the three fan speeds.

- Automatic selection of the three fan speeds according to the difference between the set temperature and the room temperature.

- Simultaneous thermostatic control on the valves and fan.

- Thermostatic control on the valves and continuous fan operation.

- Thermostatic control on the valves, for 4-pipe systems, with automatic summer/winter cycle switching according to the air temperature, with 2°C dead zone.

For the thermostatic control (ON-OFF) of water valve(s).

Any TME minimum water probemust be connected to terminalboard.

In the winter cycle only, if a minimumsensor is connected (TME accessorylocated between the fins of the heatexchange coil), the fan coil will startup only if the water temperature risesabove 42°C and shut down whenwater temperature drops below 38°C.

Après avoir choisi les fonctions vou-lues, monter la commande muraleen veillant à la placer sur le mur dulocal à conditionner à une hauteurde 1,5 m environ, sur une cloisonet loin de sources de chaleur et decourants d’air froid; connecter lebornier placé sur la carte électro-nique au bornier placé sur le flancdu ventilo-convecteur selon le sché-ma sélectionné et en respectantles schémas électriques.

Pour la connexion entre thermostatet ventilo-convecteur utiliser des câ-bles de section minimum 0,75 mm2.

La commande peut gérer les fonc-tions suivantes:

- Mise en marche et arrêt du ventilo- convecteur.

- Programmation de la température ambiante voulue (SET).

- Possibilité de sélectionner le cycle de fonctionnement été ou hiver directement à partir du tableau de commande.

- Sélection manuelle des trois vites- ses du ventilateur.

- Sélection automatique des trois vitesses du ventilateur en fonction de l’écart existant entre la tempé- rature programmée et la tempéra- ture ambiante.

- Thermostatation simultanée des vannes et du ventilateur.

- Thermostatation sur les vannes et fonctionnement continu du ventilateur.

- Thermostatation sur les vannes, pour des installations à 4 tubes, avec commutation automatique été-hiver en fonction de la tempé- rature de l’air, avec zone morte.

Adaptée au contrôle thermostatique(ON-OFF) de la ou des vannes àeau.

Si on installe une sonde de tempé-rature minimale eau TME, elle doitêtre raccordée au bornier.

En connectant la sonde de tempé-rature minimale (accessoire TMEplacée entre les ailettes de la bat-terie d’échange thermique), encycle hiver seulement, le ventila-teur ne se mettra en marche quesi la température de l’eau est supé-rieure à 42°C et s’arrêtera quandcelle-ci est inférieure à 38°C.

Nachdem die gewünschten Funktioneneingestellt wurden, das Steuergerätan einer Innenwand in einer Höhevon zirka 1,5 m und fern von Wärme-quellen und Kaltluftströmen montieren;die Klemmleiste an der Elektronik-platine gemäß des gewähltenSchemas und unter Einhaltung derSchaltpläne mit der Klemmleiste ander Seite des Lüftungskonvektorsverbinden.

Für die Verbindung zwischen Thermostatund Lüftungskonvektor Drähte miteinem Querschnitt von min. 0,75 mm2

benutzen.

Das Steuergerät kann die folgendenFunktionen verwalten:

- Ein- und Ausschalten des Lüftungs- konvektors.

- Einstellung der gewünschten Raum- temperatur (SET).

- Möglichkeit des Einstellens von Sommer- oder Winterbetrieb direkt an der Schalttafel oder.

- Manuelle Einstellung der drei Ventilatordrehzahlen.

- Automatische Einstellung der drei Ventilatordrehzahlen entsprechend der Abweichung zwischen eingestellter Set Temperatur und der effektiven Raumtemperatur.

- Gleichzeitige Temperaturregelung der Ventile und des Ventilators.

- Temperaturregelung der Ventile und Dauerbetrieb des Ventilators.

- Temperaturregelung der Ventile für 4-Leiter-Systeme mit automatischer Sommer-/Winterumschaltung, je nach Lufttemperatur, mit Totbereich von 2°C.

Geeignet für die Thermostatsteuerung(ON-OFF) des Wasserventils bzw.der Wasserventile.

Die eventuelle MindesstandsondeTME wird an die Klemmleisteangeschlossen.

Durch Anschließen der Mindest-sonde (Zubehör TME zwischenden Lamellen des Wärmetauscher-registers, wird der Ventilator nureingeschaltet, wenn die Wasser-temperatur über 42°C beträgt, undausgeschaltet, wenn sie bis unter38°C absinkt.

Después de haber elegido las fun-ciones deseadas, montar el mandode pared poniendo atención en colo-carlo en la pared del local a acondi-cionar a una altura de 1,5 m aproxi-madamente, en un tabique y lejos delas fuentes de calor y de las corrientesde aire frío; conectar la caja de bornessituada sobre la tarjeta electrónicaa la caja de bornes situada en ellado del ventilador convector según elesquema seleccionado y respetandolos esquemas eléctricos.

Para la conexión entre el termostatoy el ventilador convector usar cablescon una sección mínim de 0,75 mm2.

El mando puede gestionar las si-guientes funciones:

- Encendido y apagado del venti- lador convector.

- Introducción de la temperatura ambiente deseada (SET).

- Posibilidad de seleccionar el ciclo de funcionamiento verano o invierno directamente desde el teclado del mando.

- Selección manual de las tres velo- cidades del ventilador.

- Selección automática de las tres velocidades del ventilador en fun- ción de la diferencia existente entre la temperatura introducida como set y la temperatura ambiente.

- Termostatación de las válvulas y los ventiladores al mismo tiempo.

- Termostatación sobre las válvulas y funcionamiento contínuo del ventilador.

- Termostatación sobre las válvulas, para instalaciones de 4 tubos, con conmutación automática verano- invierno en función de la temperatura del aire, con zona muerta de 2°C.

Apto para el control termostático(ON-OFF) de la/las válvula/s delagua.

La eventual sonda de mínima aguaTME se tiene que conectar a la cajade bornes.

Conectando la sonda de mínima(accesorio TME situado entre lasaletas de la batería de cambio tér-mico), en el ciclo invernal, el venti-lador entrará en función únicamentesi la temperatura del agua es supe-rior a 42°C y se cerrará cuandoesta última sea inferior a 38°C.

Na de keuze van de gewenste functies,wordt de bediening gemonteerd aande muur. Voor een correcte werking,moet de bediening van de thermostaatworden geplaatst aan de wand van hetlokaal dat moet worden verwarmd/afgeloed, op een hoogte van circa 1,5meter en ver verwijderd van warm-tebronnen en koude luchtstromen; sluithet klemmenbord op de elektronischefiche aan op het klemmenbord op dezijkant van de ventilator-convector,overeenkomstig het geselecteerdschema en de schakelschema’s.

Voor de verbinding tussen de ther-mostaat en de ventilator-convector,gebruik draden met een minimaledoorsnede van 0,75 mm2.

De bediening kan de volgendefuncties beheren:

- In- en uitschakelen van de ventilator- convector.

- Instelling van de gewenste omgevings- temperatuur (SET).

- De mogelijkheid de winter- of zomer- cyclus te kiezen rechtstreeks met de knoppen van de bediening of.

- Manuele selectie van drie snelheden voor de ventilator.

- Automatische selectie van de drie snelheden voor de ventilator, in functie van het bestaand verschil tussen de ingestelde temperatuur (SET) en de omgevingstemperatuur.

- Gelijktijdige thermostatische regeling kleppen en ventilator.

- Thermostatische regeling kleppen en continue werking ventilator.

- Thermostatische regeling kleppen, voor installaties met 4 leidingen, en automatische omschakeling Zomer/ Winter in functie van de temperatuur van de lucht, met dode zone van 2°C.

Geschikt voor de thermostatischeregeling (ON-OFF) de waterklep(pen).

De eventuele uitschakelthermostaatTME moet aangesloten zijn op hetklemmenbord.

Wanneer de uitschakelthermostaatin de wintercyclus (accessoire TMEtussen de polen van de batterij voorde warmtewisseling), treedt deventilator alleen in werking wanneerde temperatuur van het water 42°Coverschrijdt en schakelt uit wanneerde temperatuur van het water onder38°C zakt.

39 39A

Type Code

TMO-503-SV2 9060173 COMANDO ELETTRICOCON TERMOSTATO

ELETTRONICO

ELECTRIC CONTROL UNITWITH ELECTRONIC

THERMOSTAT

COMMANDE ELECTRIQUEAVEC THERMOSTAT

ELECTRONIQUE

ELEKTRISCHE STEUERUNGMIT ELEKTRONISCHEM

THERMOSTAT

CONTROL ELÉCTRICOCON TERMOSTATO

ELECTRÓNICO

ELEKTRISCHE BEDIENINGMET ELEKTRONISCHE

THERMOSTAAT

TMO-503-SV2Cod. 9060173

TMO-503-SV2Code 9060173

TMO-503-SV2Code 9060173

TMO-503-SV2Art. Nr. 9060173

TMO-503-SV2Cód. 9060173

TMO-503-SV2Code 9060173

Page 40:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

MIN

MED

MAX

E

9

MC

87654321

10

M

BU

BK

8 9

5

BK

BU

OG

10

BU

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

OG

7

75

BK

PE 14

3

NL 15

11

BN

134

6

RD

MFC

E

L N

Q1

230Vac50Hz

PE

MAX

MED

MIN

E2

E1

10

12345678

MC

9

PE

230Vac50Hz

Q1

N L

E1E2

MFC

RD

6

4 13

BN

11

15L N

3

14PE

BK

5 7

7

OG

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BU

10

OG

BU

BK

5

98

BK

M

BU

TM

O-5

03

-SV

2

TM

O-5

03

-SV

2MIN

MED

MAX

E

9

MC

87654321

10

M

BU

BK

8 9

5

5

BK

BU

OG

10

BU

BN

OG

230V

OG

BN

50Hz

12

BK

RD

BK

GN

YE

8

1

RD

10

BU

129

4MC

116

2

RD

2

OG

7

75

BK

BN

PE 14

3

1

NL 15

11

BN

134

6

43

RD

MFC

E

L N

Q1

230Vac50Hz

PE

MAX

MED

MIN

E2

E1

10

12345678

MC

9

PE

230Vac50Hz

Q1

N L

E1E2

MFC

RD

3 4

6

4 13

BN

11

15L N

1

3

14PE

BN

BK

5 7

7

OG

2

RD

2

6 11

MC4

9 12

BU

10

RD

1

8

GN

YE

BK

RD

BK

12

50Hz

BN

OG

230V

OG

BN

BU

10

OG

BU

BK

5

5

98

BK

BU

M

TM

O-5

03

-SV

2

TM

O-5

03

-SV

2

40 40A

Negli impianti a 4 tubi corredati divalvole, con presenza costante deifluidi di alimentazione, esiste la pos-sibilità di passare automaticamentedalla fase riscaldante a quella raf-frescante (o viceversa) in base alloscostamento della temperatura am-biente rispetto a quella fissata conil termostato, con zona morta inter-media di 2°C.

In four-tube installations with valvesand constant presence of fluid inthe circuits, switching between theheating and cooling phase (and viceversa) can be automatic, accordingto the difference between roomtemperature and the temperatureset on the thermostat, with anintermediate dead zone of 2°C.

Dans les installations à 4 tuyauterieséquipées de vannes, avec présenceconstante des fluides d’alimentation,on a la possibilité de passer auto-matiquement de la phase de chauffageà celle de rafraîchissement (et viceversa) sur la base de l’écart entre latempérature ambiante et celle régléesur le thermostat, avec une zonemorte intermédiaire de 2°C.

Bei den mit Ventilen ausgestattetenAnlagen mit 4 Rohren mit konstanterPräsenz der Versorgungsflüssigkeiten,ist die Möglichkeit gegeben, je nachder Abweichung der Raumtemperaturim Vergleich zu der am Thermostateingegebenen Temperatur automatischvon der Heiz- zur Kühlphase (undumgekehrt) überzugehen, mit einemÜbergangs-Totbereich von 2°C.

En las instalaciones con 4 tubosprovistos de válvulas, con presen-cia constante de los fluidos de ali-mentación, cabe la posibilidad depasar automáticamente desde lafase calefactora a la refrescadora(y viceversa) según la diferenciaentre la temperatura ambiente y ladeterminada con el termostato; conzona muerta intermedia de 2 °C.

Voor de installaties met 4 leidingenuitgerust met kleppen en met eenconstante aanwezigheid van voedings-vloeistoffen, kan automatisch wordenovergeschakeld van de verwarmendefase naar de afkoelende fase (ofomgekeerd), in functie van het verschiltussen de omgevingstemperatuur en dethermostatisch ingestelde temperatuur;met een dode tussenzone van 2°C.

Applicato sulla strutturadei ventilconvettori, consenteil controllo di più apparecchi

(Max 8)su segnale di un unico

comando remoto.

Fitted to the frameof the fan coil, this enables

up to eight unitsto be cotrolled by the signal

from a singleremote control unit.

Appliqué sur la structuredes ventilo-convecteurs, permet

de contrôlerplusieurs appareils (8 maxi)

sur signal d’uneseule commande à distance.

Diese Vorrichtung wird an derStruktur der Gebläsekonvektoren

angebracht und gestattetdie Steuerung meherer (max. 8)

Geräte mit dem Signaleiner einzigen Fernbedienung.

Aplicado en la structurade los fan coils

permite controlar variosaparatos (como máximo 8)

mediante la señalde un único mando a distancia.

Gemonteerd op de structuurvan de ventilatorconvectors,

voor de bediening van meerdereapparaten (max 8) via

een signaal afkomstig van éénenkele afstandsbediening.

SELETTOREDI VELOCITÀ RICEVENTE

SPEED SELECTORRECEIVER

SELECTEURDE VITESSE RECEPTEUR

DREHZAHLWÄHLSCHALTEREMPFÄNGER

SELECTORDE VELOCIDAD RECEPTOR

SNELHEIDSSCHAKELAARONTVANGER

TMO-503-SV2 conSEL-CB – Cod. 9066304

(MV - MVB)

TMO-503-SV2 withSEL-CB – Code 9066304

(MV - MVB)

TMO-503-SV2 avecSEL-CB – Code 9066304

(MV - MVB)

TMO-503-SV2 mitSEL-CB – Art. Nr. 9066304

(MV - MVB)

TMO-503-SV2 conSEL-CB – Cód. 9066304

(MV - MVB)

TMO-503-SV2 metSEL-CB – Code 9066304

(MV - MVB)

SEL-CR – Cod. 9066311

(MO - IV - IO)SEL-CR – Code 9066311

(MO - IV - IO)SEL-CR – Code 9066311

(MO - IV - IO)SEL-CR – Art. Nr. 9066311

(MO - IV - IO)SEL-CR – Cód. 9066311

(MO - IV - IO)SEL-CR – Code 9066311

(MO - IV - IO)

Type Code

SEL-CB 9066304

Type Code

SEL-CR 9066311

con 2 valvole - with 2 valves - avec 2 vannesmit 2 Ventile - con 2 válvulas - met 2 kleppen

con 1 valvola - with 1 valve - avec 1 vannemit 1 Ventil - con 1 válvula - met 1 klep

con 2 valvole - with 2 valves - avec 2 vannesmit 2 Ventile - con 2 válvulas - met 2 kleppen

con 1 valvola - with 1 valve - avec 1 vannemit 1 Ventil - con 1 válvula - met 1 klep

Page 41:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

41 41A

Termostatazionesul ventilatore.

Thermostaticcontrol on the fan.

Thermostatsur le ventilateur.

Temperaturregelungam Ventilator.

Termostataciónsobre el ventilador.

Thermostatischeregeling ventilator.

Termostatazionecontemporanea

delle valvolee del ventilatore.

Simultaneousthermostatic control

on the valves and fan.

Thermostatation simultanéedes vannes

et du ventilateur.

GleichzeitigeTemperaturregelung

der Ventileund des Ventilators.

Termostataciónde las válvulas

y los ventiladoresal mismo tiempo.

Gelijktijdigethermostatische

regeling kleppen en ventilator.

Termostatazionesulla valvola

e funzionamentocontinuo del ventilatore.

Thermostatic controlon the valve

and continuous fan operation.

Thermostatationsur la vanne

et fonctionnement continudu ventilateur.

Temperaturregelungder Ventil

und Dauerbetriebdes Ventilators.

Termostataciónsobre la válvula

y funcionamiento contínuodel ventilador.

Thermostatischeregeling klep en continue

werking ventilator.

B

C

MFCNLPE 1310 12 1411 157 9854 6

BU

BK

GN

YE

MC

101168793N

M230V50Hz

BU

RD

OG

BK

PE

L N

Q1

230Vac50Hz

MFC

GN

YE

BK

BU

64 5 8 97 1511 141210 13PE L N

10

MC

879N 1163

PE

L N

Q1

230Vac50Hz

M230V50Hz

BU

RD

OG

BK

E

MFC

GN

YE

BK BU

64 5 8 97 1511 141210 13PE L N

9 7 10

MC

3N 118 6

PE

L N

Q1

230Vac50Hz

M230V50Hz

BU

RD

OG

BK

E

A

C

B

Soloper impianti a 2 tubi.

Per una buona sensibilità della son-da, il comando con termostato deveessere posizionato sulla parete dellocale da climatizzare, all’altezzadi circa 1,5 m e lontano da fonti dicalore e da correnti d’aria fredda.

Per il collegamento tra termostatoe ventilconvettore utilizzare condut-tori con sezione minima 0,75 mm2.

Non utilizzabile con i ripetitori.

Il comando può gestire le seguentifunzioni:

- Accensione e spegnimento del ventilconvettore.

- Impostazione della temperatura ambiente desiderata (SET).

- Possibilità di selezionare il ciclo di funzionamento estivo o invernale direttamente dalla pulsantiera del comando.

- Selezione manuale delle tre velo- cità del ventilatore.

- Termostatazione contemporanea delle valvole e del ventilatore.

- Termostatazione sulla valvola e funzionamento continuo del ventilatore.

Idoneo per il controllo termostatico(ON-OFF) della valvola acqua.

2 pipes unitsonly.

To guarantee correct sensor sensitivity,the control unit with thermostat mustbe positioned at a height of about1.5 m on a wall of the room to be airconditioned, away from heat sourcesand currents of cold air.

For the connection between thethermostat and the fan coil, use cableswith a minimum cross-section of0.75 mm2.

Cannot be used with repeaters.

The control unit can manage thefollowing functions:

- Turning the fan coil on and off.

- Setting and reading the required room temperature (SET).

- Selecting the summer or winter operating cycle directly from the control keypad.

- Manual selection of the three fan speeds.

- Simultaneous thermostatic control on the valves and fan.

- Thermostatic control on the valve and continuous fan operation.

For the thermostatic control (ON-OFF) of water valve.

Seulementpour installation à 2 tubes.

Pour une bonne sensibilité de lasonde, la commande avec thermostatdoit être placée sur la paroi du localà climatiser, à une hauteur d’environ1,5 m et loin de toute source de cha-leur ou de courants d’air froid.

Pour la connexion entre thermostatet ventilo-convecteur utiliser des câ-bles de section minimum 0,75 mm2.

Pas utilisable avec les répétiteurs.

La commande peut gérer les fonc-tions suivantes:

- Mise en marche et arrêt du ventilo- convecteur.

- Programmation de la température ambiante voulue (SET).

- Possibilité de sélectionner le cycle de fonctionnement été ou hiver directement à partir du tableau de commande.

- Sélection manuelle des trois vites- ses du ventilateur.

- Thermostatation simultanée des vannes et du ventilateur.

- Thermostatation sur la vanne et fonctionnement continu du ventilateur.

Adaptée au contrôle thermostatique(ON-OFF) de la vanne à eau.

Nur für2-Leiter-Anlagen.

Für eine gute Ansprechempfindlichkeitder Sonde muss die Steuerung mitThermostat an der Wand des Raumes,der klimatisiert werden soll, angebrachtwerden, und zwar in einer Höhe vonetwa 1,5 Meter und nicht in der Nähevon Wärmequellen und Zugluft.

Für die Verbindung zwischen Thermostatund Lüftungskonvektor Drähte miteinem Querschnitt von min. 0,75 mm2

benutzen.

Nicht mit Mehrfach-Steuerrelaisverwendbar.

Das Steuergerät kann die folgendenFunktionen verwalten:

- Ein- und Ausschalten des Lüftungs- konvektors.

- Einstellung der gewünschten Raum- temperatur (SET).

- Möglichkeit des Einstellens von Sommer- oder Winterbetrieb direkt an der Schalttafel oder.

- Manuelle Einstellung der drei Ventilatordrehzahlen.

- Gleichzeitige Temperaturregelung der Ventile und des Ventilators.

- Temperaturregelung der Ventil und Dauerbetrieb des Ventilators.

Geeignet für die Thermostatsteuerung(ON-OFF) der Wasserventil.

Sólopara instalaciones de 2 tubos.

Para una buena sensibilidad de lasonda es preciso colocar el controlcon termostato en la pared del cuar-to a climatizar, a una altura de aproxi-madamente 1,5 m y lejos de fuentesde calor y de corrientes de aire frío.

Para la conexión entre el termostatoy el ventilador convector usar cablescon una sección mínim de 0,75 mm2.

No utilizable con los repetidores.

El mando puede gestionar las si-guientes funciones:

- Encendido y apagado del venti- lador convector.

- Introducción de la temperatura ambiente deseada (SET).

- Posibilidad de seleccionar el ciclo de funcionamiento verano o invierno directamente desde el teclado del mando.

- Selección manual de las tres velo- cidades del ventilador.

- Termostatación de las válvulas y los ventiladores al mismo tiempo.

- Termostatación sobre la válvula y funcionamiento contínuo del ventilador.

Apto para el control termostático(ON-OFF) de la válvula del agua.

Alleen voorsystemen met 2 pijpen.

Voor een correcte werking van de sonde,moet de bediening van de thermostaatworden geplaatst aan de wand vanhet lokaal dat moet worden verwarmd/afgekoeld, op een hoogte van circa 1,5meter en ver verwijderd van warmte-bronnen en koude luchtstromen.

Voor de verbinding tussen de ther-mostaat en de ventilator-convector,gebruik draden met een minimaledoorsnede van 0,75 mm2.

Niet toepasbaar met versterkers.

De bediening kan de volgendefuncties beheren:

- In- en uitschakelen van de ventilator- convector.

- Instelling van de gewenste omgevings- temperatuur (SET).

- De mogelijkheid de winter- of zomer- cyclus te kiezen rechtstreeks met de knoppen van de bediening of.

- Manuele selectie van drie snelheden voor de ventilator.

- Gelijktijdige thermostatische regeling kleppen en ventilator.

- Thermostatische regeling klep en continue werking ventilator.

Geschikt voor de thermostatischeregeling (ON-OFF) de waterklep.

Type Code

T2T 9060174 TERMOSTATOELETTROMECCANICO

CONTROL PANELWITH

ELECTROMECHANICALTHERMOSTAT

PANNEAU DE COMMANDEAVEC

THERMOSTATÉLECTROMÉCANIQUE

FERNBEDIENUNG MITELEKTRISCH-

OHEMECHANISCHEMTHERMOSTAT

PANEL DE MANDOSCON

TERMOSTATOELECTRÓMECÁNICO

ELEKTROMECHANISCHETHERMOSTAAT

T2T – Cod. 9060174 T2T – Code 9060174 T2T – Code 9060174 T2T – Art. Nr. 9060174 T2T – Cód. 9060174 T2T – Code 9060174

A

Page 42:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

RD

BK

RD

BN

RD

BK

RD

BN

RD

BK

RD

BN

TME

TMM

CH 15-25

Da posizionare in contatto con iltubo di alimentazione.

Abbinabile ai comandi:CB, CB-T, CB-IAQ, MO-3V,MO-3V-IAQ.

Valido per apparecchi funzionantiunicamente in inverno.

Arresta l’elettroventilatore quandola temperatura dell’acqua è inferio-re ai 30°C, e lo fa ripartire quandoquesta raggiunge i 38°C.

Position in contact with the watersupply pipe.

For use with control units:CB, CB-T, CB-IAQ, MO-3V,MO-3V-IAQ.

Valid for winter mode operationonly.

Stops the fan when the watertemperature drops below 30°Cand starts it up again when thetemperature reaches 38°C.

Doit être placée en contact avecle tuyau d’alimentation.

Associable aux commandes:CB, CB-T, CB-IAQ, MO-3V,MO-3V-IAQ.

Valide pour des appareils fonction-nant uniquement en hiver.

Arrête le ventilateur quand la tem-pérature de l’eau est inférieure à30°C et le fait repartir quand elleatteint 38°C.

Diese Sonde wird in Kontakt mitdem Zuleitungsrohr angebracht.

Kombinierbar mit den Steuerungen:CB, CB-T, CB-IAQ, MO-3V,MO-3V-IAQ.

Gültig nur für den Heizbetrieb.

Stoppt den Elektroventilator, wenndie Wassertemperatur unter 30°Cliegt und setzt ihn wieder in Gang,wenn sie 38°C erreicht.

A colocar en contacto con el tubode alimentación.

Combinable con los dispositivos deaccionamiento: CB, CB-T, CB-IAQ,MO-3V, MO-3V-IAQ.

Vale para aparatos que funcionansólo en inverno.

Detiene el electro-ventilador cuandola temperatura del agua es inferiora los 30°C y lo pone de nuevo enmarcha cuando la temperaturaalcanza los 38°C.

Moet in contact met de voedings-leiding geplaatst worden.

Combinerend met de bedieningen:CB, CB-T, CB-IAQ, MO-3V,MO-3V-IAQ.

Alleen van toepassing voor apparatendie alleen op wintercyclus werken.

Schakelt de elektroventilator uitwanneer de watertemperatuur minderdan 30°C bedraagt, en schakelthem weer in als de temperatuur38°C bereikt.

SONDA DI MINIMA LOW TEMPERATURECUT-OUT THERMOSTAT

SONDE DE TEMPÉRATUREMINIMUM

MINDEST-TEMPERATURFÜHLER

SONDA DE MÍNIMA UITSCHAKEL-THERMOSTAAT

TMM – Cod. 9053048 TMM – Code 9053048 TMM – Code 9053048 TMM – Art. Nr. 9053048 TMM – Cód. 9053048 TMM – Code 9053048

Da posizionare fra le alette dellabatteria di scambio termico.

Abbinabile ai comandi:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI ed i corrispondenti IAQ.

Per il collegamento al comando, ilcavo della sonda TME deve essereseparato dai conduttori di potenza.

Durante il funzionamento invernalearresta l’elettroventilatore quandola temperatura dell’acqua è inferio-re ai 38°C, e lo fa ripartire quandoquesta raggiunge i 42°C.

Position between the fins of theheat exchanger coil.

For use with control units:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI and corresponding IAQs.

When connecting the control, theTME probe cable must be separatedfrom the power supply wires.

During winter operation stops thefan when the water temperature dropsbelow 38°C and starts it up againwhen the temperature reaches 42°C.

Doit être placée entre les ailettesde la batterie d’échange thermique.

Associable aux commandes:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI et IAQ correspondants.

Pour le raccordement à la commande,le câble de la sonde TME doit êtreséparé des câbles de puissance.

Pendant le fonctionnement hiverarrête le ventilateur quand la tem-pérature de l’eau est inférieure à38°C et le fait repartir quand elleatteint 42°C.

Diese Sonde wird zwischen denLeitlamellen der Wärmetauscher-Batterie angebracht.

Kombinierbar mit den Steuerungen:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI und entsprechende IAQ.

Für den Anschluss an die Steuerungmuss das Kabel des Fühlers TME vonden Leistungsleitungen getrennt sein.

Der Fühler hält bei Winterbetrieb denVentilator an, wenn die Temperaturdes Wassers unter 38°C ist, undsetzt ihn wieder in Betrieb, wennsie 42°C erreicht hat.

A colocar entre las aletas de labatería de intercambio térmico.

Combinable con los dispositivos deaccionamiento: CB-C, CB-AU,TMO-T, TMO-T-AU, TMO-DI e IAQcorrespondientes.

Para la conexión al mando, el cablede la sonda TME debe separarsede los conductores de potencia.

Durante el funcionamiento en invier-no para el electroventilador cuandola temperatura del agua es inferiora 38°C y lo vuelve a poner en mar-cha cuando esta alcanza los 42°C.

Te plaatsen tussen de ribben vande warmtewisselaars.

Combinerend met de bedieningen:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI en overeenkomstige IAQs.

Voor de aansluiting op de besturing,moet de kabel van de TME-sondegescheiden zijn van de stroomdraden.

Tijdens de wintercyclus schakelt hij deelektroventilator uit als de temperatuurvan het water minder dan 38°Cbedraagt, en opnieuw inschakeltals de temperatuur 42°C bereikt.

SONDA DI MINIMA LOW TEMPERATURECUT-OUT THERMOSTAT

SONDE DE TEMPÉRATUREMINIMUM

MINDEST-TEMPERATURFÜHLER

SONDA DE MÍNIMA UITSCHAKEL-THERMOSTAAT

TME – Cod. 3021091 TME – Code 3021091 TME – Code 3021091 TME – Art. Nr. 3021091 TME – Cód. 3021091 TME – Code 3021091

42 42A

Cambio stagionale automatico daposizionare in contatto con il tubodi alimentazione.

Solamente per impianti a due tubi.

Abbinabile ai comandi:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI.

Automatic summer/winter switch tobe installed in contact with the watercircuit (for 2-tube installations only).

Only for 2 pipe installations.

For use with control units:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI.

Commutateur saisonnier automa-tique à installer en contact avec letube d’alimentation.

Uniquement pour installations à 2tubes.

Associable aux commandes:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI.

Automatischer Saisonwechsel, inKontakt mit dem Wasserrohr zuinstallieren.

Nur für 2-Leiter-Anlagen.

Kombinierbar mit den Steuerungen:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI.

Cambio estacional automático quese tiene que colocar en contactocon el conduco de alimentación.

Solo con instalaciones con 2 tubos.

Combinable con los dispositivos deaccionamiento: CB-C, CB-AU,TMO-T, TMO-T-AU, TMO-DI.

Automatische seizoenwisseling diein contact met de voedingsleidingmoet worden geplaatst.

Enkel voor installaties met tweeleidingen.

Combinerend met de bedieningen:CB-C, CB-AU, TMO-T, TMO-T-AU,TMO-DI.

CHANGE-OVER CHANGE-OVER CHANGE-OVER CHANGE-OVER CHANGE-OVER CHANGE-OVER

CH 15-25 – Cod. 9053049 CH 15-25 – Code 9053049 CH 15-25 – Code 9053049 CH 15-25 – Art. Nr. 9053049 CH 15-25 – Cód. 9053049 CH 15-25 – Code 9053049

Page 43:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

ATTENZIONE!PRIMA DI QUALSIASI

PULIZIAE MANUTENZIONE,

TOGLIEREL’ALIMENTAZIONE

ALL’APPARECCHIO.

IMPORTANT!BEFORE CARRYING OUT

CLEANINGOR MAINTENANCE,

MAKE SURE THE POWERTO THE UNIT

IS TURNED OFF.

ATTENTION!AVANT

TOUTE OPERATIONDE NETTOYAGE ET

D’ENTRETIEN,COUPER L’ALIMENTATION

DE L’APPAREIL.

ACHTUNG!VOR BEGINN

VON REINIGUNGS- UNDWARTUNGSEINGRIFFEN

MUSS DIE STROMZUFUHRZUM GERÄT

UNTERBROCHEN WERDEN.

ATENCIÓN!ANTES DE EFECTUAR

CUALQUIER OPERACIÓNDE LIMPIEZA

Y MANTENIMIENTOCORTAR LA ALIMENTACIÓN

PARA EL APARATO.

OPGELET!VOOR ELKE

SCHOONMAAK- ENONDERHOUDSBEURT,DE STEKKER VAN HET

APPARAAT UIT HETSTOPCONTACT TREKKEN.

ATTENZIONE!RIMONTARE

SEMPRE IL FILTRODOPO

LA SUA PULIZIA.

IMPORTANT!ALWAYS

REPLACE THE FILTERAFTER CLEANING.

ATTENTION!APRES L’AVOIR NETTOYE,

NE JAMAIS OUBLIERDE REMONTER

LE FILTRE.

ACHTUNG!NICHT VERGESSEN,DEN FILTER NACHDER REINIGUNG

WIEDER EINZUBAUEN.

ATENCIÓN!DESPUÉS DE LIMPIARLO

VOLVER A MONTARSIEMPRE EL FILTRO

EN SU SITO.

OPGELET!HERPLAATS DE FILTER

STEEDS NA EENSCHOONMAAKBEURT.

43 43A

PULIZIA,MANUTENZIONE,RICAMBI

Solo personale addetto alla manu-tenzione e precedentemente ad-destrato, può intervenire sulle ap-parecchiature.

ELETTROVENTILATORE:Non richiede alcun tipo di manu-tenzione.

BATTERIA:Non richiede alcun tipo di ordina-ria manutenzione.

FILTRO:Con l’ausilio di un utensile, sgan-ciare il profilo portafiltro ed estrar-re il filtro dalle guide.

Si pulisce periodicamente usandoun’aspirapolvere oppure percuo-tendolo leggermente.

Sostituirlo nel caso non si possapiù pulire.

RICAMBI:Per l’ordinazione delle parti diricambio citare sempre il modellodell’apparecchio e la descrizionedel componente.

CLEANING,MAINTENANCEAND SPARE PARTS

Maintenance of the unit must becarried out by trained maintenancepersonnel only.

FAN:No maintenance required.

HEAT EXCHANGER COIL:No ordinary maintenance required.

FILTER:Using a suitable tool, unhook thefilter holder strip and extract thefilter from the guides.

Clean regularly with a vacuumcleaner or shake lightly.

When it can no longer be cleaned,replace.

SPARE PARTS:To order spare parts, always givethe model of appliance and adescription of the component.

NETTOYAGE,ENTRETIEN ET PIECESDE RECHANGE

REINIGUNG,WARTUNG UNDERSATZTEILE

LIMPIEZA,MANTENIMIENTOY REPUESTOS

SCHOONMAAK,ONDERHOUD,WISSELSTUKKEN

Seul le personnel chargé de l’entretienet ayant été formé dans ce but peutintervenir sur les appareils.

VENTILATEUR:Ne nécessite aucun type d’entretien.

BATTERIE:Ne nécessite aucun type d’entretien.ordinaire.

FILTRE:Au moyen d’un outil, décrocher leprofilé porte-filtre et retirer le filtrede ses guides.

Doit être nettoyé périodiquementà l’aide d’un aspirateur ou en lefrappant légèrement.

Le remplacer lorsqu’il n’est pluspossible de le nettoyer.

PIECES DE RECHANGE:Pour la commande des piècesde rechange, indiquer toujours lemodèle de l’appareil et la descriptiondu composant.

Nur das mit der Wartung betrauteund vorher entsprechend geschultePersonal darf Eingriffe an denGeräten vornehmen

ELEKTROVENTILATOR:Dieser bedarf keinerlei Wartung.

BATTERIE:Diese bedarf keiner ordentlichenWartung.

FILTER:Mit Hilfe eines Werkzeugs dasFilter-Halteprofil aushängen und denFilter aus den Führungen nehmen.

Der Filter wird regelmäßig miteinem Staubsauger oder durchvorsichtiges Ausklopfen gesäubert.

Wenn er sich nicht mehr reinigenlässt, muss er ersetzt werden.

ERSATZTEILE:Bei Ersatzteilbestellungen immer dasGerätemodell und die Bezeichnungdes Teils angeben.

Sólo personal encargado del mante-nimiento y previamente capacitadopuede efectuar operaciones sobrelos aparatos.

VENTILADOR:No requiere ninguna clase demantenimiento.

BATERÍA:No requiere ninguna clase demantenimiento ordinario.

FILTRO:Con el auxilio de una herramienta,desenganchar el perfil porta-filtroy retirar el filtro de las guías.

Se limpia periódicamente usandouna aspiradora o golpeándolo lige-ramente.

Si no es posible limpiarlo sustituirlo.

REPUESTOS:Para pedir piezas de repuesto in-dicar siempre el modelo del aparatoy la descripción del componente.

Wend u uitsluitend tot opgeleidonderhoudspersoneel voor hetonderhoud van het apparaat.

ELEKTROVENTILATOR:Vergt geen enkel type onderhoud.

BATTERIj:Vergt geen enkel type gewoononderhoud.

FILTER:Met behulp van gereedschap, haaktu de filterhouder los en haalt u hemuit zijn zitting.

Maak de filter regelmatig schoonmet een stofzuiger of door er zachtop te kloppen.

Vervang de filter indien hij niet kanworden schoongemaakt.

WISSELSTUKKEN:Bij de bestelling van de wisselstukken,vermeld u steeds het model van hetapparaat en beschrijft u het onderdeel.

Page 44:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

44 44A

RICERCA GUASTI

GUASTO1 - Il motore non gira o gira in modo non corretto.

RIMEDIO - Controllare che l’alimentazione sia inserita.

- Verificare il collegamento corretto dei fili, osservando gli schemi elettrici.

- Verificare la posizione dell’interruttore generale, del commutatore stagionale e del termostato.

GUASTO2 - L’apparecchio non scalda/raffredda più come in precedenza.

RIMEDIO - Controllare che il filtro sia sufficientemente pulito.

- Verificare sfiatando la batteria che non sia entrata aria nel circuito idraulico.

GUASTO3 - L’apparecchio perde acqua.

RIMEDIO - Controllare che l’inclinazione sia in direzione dello scarico condensa.

- Controllare che lo scarico condensa non sia ostruito.

TROUBLESHOOTING

PROBLEM1 - The motor does not rotate or rotates incorrectly.

REMEDY - Make sure the power to the unit is on.

- Make sure the wires are correctly connected, referring to the wiring diagram.

- Control if the main switch, the seasonal commutator and the thermostat are in the right position.

PROBLEM 2 - The unit does not heat/cool as before.

REMEDY - Make sure the filter is clean.

- Make sure the hydraulic circuit is free from air by venting the heat exchanger.

PROBLEM 3 - The appliance leaks water.

REMEDY - Make sure it is sloping in the direction of the condensate drain.

- Make sure the condensate drain is not clogged.

DEPANNAGE FEHLERSUCHEINVESTIGACIÓNDE AVERÍAS

OPSPORENDEFECTEN

DEFAUT1 - Le moteur ne tourne pas ou tourne de manière incorrecte.

REMEDE - Contrôler que l’alimentation est branchée.

- Vérifier le bon raccordement des conducteurs à l’aide des schémas électriques.

- L’interrupteur général et le commutateur saisonnier soient dans la position correcte.

DEFAUT2 - L’appareil ne chauffe ou ne refroidit plus comme avant.

REMEDE - Contrôler que le filtre est suffisamment propre.

- Vérifier, en purgeant la batterie, que de l’air n’est pas entré dans le circuit hydraulique.

DEFAUT3 - L’appareil perd de l’eau.

REMEDE - Contrôler que l’évacuation des condensats est inclinée dans la bonne direction.

- Contrôler que l’évacuation des condensats n’est pas bouchée.

STÖRUNG1 - Der Motor dreht nicht oder dreht nicht korrekt.

ABHILFE - Kontrollieren, ob die Spannungs- versorgung zugeschaltet ist.

- Auf Grundlage der Schaltpläne den korrekten Anschluss der Drähte prüfen.

- Die Position des Haupt- schalters, des Umschalters der Betriebsart und des Thermostats kontrollieren.

STÖRUNG2 - Das Gerät heizt/kühlt nicht mehr wie zuvor.

ABHILFE - Kontrollieren, ob der Filter sauber genug ist.

- Durch Entlüften des Registers kontrollieren, ob Luft in den Wasserkreis eingedrungen ist.

STÖRUNG3 - Das Gerät verliert Wasser.

ABHILFE - Kontrollieren, ob die Schräge in Richtung des Kondensatabflusses verläuft.

- Kontrollieren, ob der Kondensatabfluss frei ist.

AVERÍA1 - El motor no gira o gira de modo incorrecto.

SOLUCIÓN - Verificar que esté conectado a la toma de corriente.

- Verificar la correcta conexión de los hilos, observando los esquemas eléctricos.

- Verificar la posición del interruptor general, del conmutador estacional y del termostato.

AVERÍA2 - El aparato ya no calienta/enfría como con anterioridad.

SOLUCIÓN - Verificar que el filtro esté bien limpio.

- Verificar purgando la batería que no haya entrado aire en el circuito hidráulico.

AVERÍA3 - El aparato pierde agua.

SOLUCIÓN - Controlar que esté inclinado en dirección a la evacuación del agua de condensación.

- Controlar que la evacuación del agua de condensación no esté obstruida.

DEFECT1 - De motor draait niet of op niet correcte wijze.

OPLOSSING - Controleer of de stekker in het stopcontact zit.

- Controleer de correcte aansluiting van de draden, conform de schakelschema’s.

- Controleer de positie van de hoofdschakelaar, de seizoensschakelaar en de thermostaat.

DEFECT2 - Het apparaat verwarmt/koelt niet meer af zoals voordien.

OPLOSSING - Controleer of de filter voldoende schoon is.

- Tap de batterij af en ga de aanwezigheid na van lucht in het hydraulisch circuit.

DEFECT3 - Er lekt water uit het apparaat.

OPLOSSING - Controleer of de helling in de richting van de afvoerbuis voor het condensatievocht loopt.

- Controleer of de afvoerbuis voor het condensatievocht niet verstopt is.

Page 45:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

100 800600400300200 150010001

40

30

20

98

7

6

5

50

4

3

2

10

34-44

74

84-94

54-64

14

24

100 800600400300200 150010001

40

30

20

98

7

6

5

50

4

3

2

10

33-43

73

83-9353-63

13

23

100 800600400300200 1000806050

1

40

30

20

9876

5

60

4

3

2

10

50

1

3-4

5-6

7-8-9

2

100 800600400300200 1000806050

1

40

30

20

9876

5

60

4

3

2

10

50

1

3-4

5-6

7-8-9

2

Batteria a 3 ranghi

3 row battery

Batterie à 3 rangs

Register mit 3 Rohrreihen

Batería de 3 filas

Batterij met 3 rijen

Batteria a 4 ranghi

4 row battery

Batterie à 4 rangs

Register mit 4 Rohrreihen

Batería de 3 filas

Batterij met 4 rijen

Batteria addizionale a 1 rango

1 row additional battery

Batterie additionnelle à 1 rang

Zusatzregisters mit 1 Rohrreihe

Batería adicional de 1 fila

Extra batterij met 1 rij

Batteria addizionale a 2 ranghi

2 row additional battery

Batterie additionnelle à 2 rangs

Zusatzregisters mit 1 Rohrreihen

Batería adicional de 2 filas

Extra batterij met 2 rijen

K 0,94 0,90 0,86 0,82 0,78 0,74 0,70

20 30 40 50 60 70 80°CK 1,14 1,08 1,02 0,96 0,90

°C 40 50 60 70 80

La perdita di carico si riferisce ad una temperatura media dell’acqua di 10°C;per temperature diverse, moltiplicare la perdita di carico per il coefficiente K riportato in tabella.

The table indicates the pressure drop for a mean water temperature of 10°C.For different water temperatures multiply by the correction factors K.

La perte de charge se référe à une température moyenne d’eau de 10°C.Pour une température différente, multiplier la perte de charge par le coefficient K de le table suivante.

Der Druckverlust bezieht sich auf eine durchschnittliche Temperatur des Wassers von 10°C;für abweichende Temperaturen den Druckverlust mit dem Koeffizienten K der Tabelle multiplizieren.

La pérdida de carga se refiere a una temperatura media del agua de 10°C;para temperaturas distintas multiplicar la pérdida de carga por el coeficiente K que figura en la tabla.

Het energieverlies verwijst naar een gemiddelde watertemperatuur van 10°C;bij verschillende temperaturen vermenigvuldigt u het energieverlies met de coëfficiënt K die u in de tabel vindt.

La perdita di carico si riferisce ad una temperatura media dell’acqua di 65°C;per temperature diverse, moltiplicare la perdita di carico per il coefficiente K riportato in tabella.

The table indicates the pressure drop for a mean water temperature of 65°C.For different water temperatures multiply by the correction factors K.

La perte de charge se référe à une température moyenne d’eau de 65°C.Pour une température différente, multiplier la perte de charge par le coefficient K de le table suivante.

Der Druckverlust bezieht sich auf eine durchschnittliche Temperatur des Wassers von 65°C;für abweichende Temperaturen den Druckverlust mit dem Koeffizienten K der Tabelle multiplizieren.

La pérdida de carga se refiere a una temperatura media del agua de 65°C;para temperaturas distintas multiplicar la pérdida de carga por el coeficiente K que figura en la tabla.

Het energieverlies verwijst naar een gemiddelde watertemperatuur van 65°C;bij verschillende temperaturen vermenigvuldigt u het energieverlies met de coëfficiënt K die u in de tabel vindt.

45 45A

PERDITE DI CARICO LATO ACQUA - PRESSURE DROP TABLEPERTES DE CHARGE CÔTE EAU - DRUCKVERLUSTE WASSER

PÉRDIDAS DE CARGA LADO AGUA - WATERLEKKEN

PERDITE DI CARICO LATO ACQUA - PRESSURE DROP TABLEPERTES DE CHARGE CÔTE EAU - DRUCKVERLUSTE WASSER

PÉRDIDAS DE CARGA LADO AGUA - WATERLEKKENDp - kPa

Portata acqua (l/h) - Water flow (l/h)Débit d’eau (l/h) - Wasserdurchflussmenge (l/h)Caudal de agua (l/h) - Waterdebiet (l/h)

Portata acqua (l/h) - Water flow (l/h)Débit d’eau (l/h) - Wasserdurchflussmenge (l/h)Caudal de agua (l/h) - Waterdebiet (l/h)

Dp - kPa

Portata acqua (l/h) - Water flow (l/h)Débit d’eau (l/h) - Wasserdurchflussmenge (l/h)Caudal de agua (l/h) - Waterdebiet (l/h)

Portata acqua (l/h) - Water flow (l/h)Débit d’eau (l/h) - Wasserdurchflussmenge (l/h)Caudal de agua (l/h) - Waterdebiet (l/h)

Dp - kPa

Dp - kPa

Page 46:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

NOTES NOTES

Page 47:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

NOTES NOTES

Page 48:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET

NOTES NOTES

Page 49:  · MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI CARISMA FAN COIL CARISMA INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET