INTRODUZIONE - bios-hitechnologysrl.it · in power on, regolano la corrente della uscita 11...

18
INTRODUZIONE L’ APPARECCHIATURA T-1100CX E’ UN ELETTROSTIMOLATORE ESTREMAMENTE PROFESSIONALE AD 11 CANALI ED E ’UN PRODOTTO INTERAMENTE PROGETTATO DALLA DITTA BIOS SNC. PER LA T-1100CX SONO STATE UTILIZZATE LE MIGLIORI TECNOLOGIE ELETTRONICHE, INFATTI E’ INTERAMENTE CONTROLLATA DA UN MICROPROCESSORE CHE GESTISCE TUTTE LE FASI DELL’ UTILIZZO, ED E’ DOTATA DI UN DISPLAY LCD GRAFICO A 256 COLORI PER VISUALIZZARE CON ESTREMA CHIAREZZA LE INDICAZIONI DI FUNZIONAMENTO. TRAMITE I 28 TASTI SI PUO’ ACCEDERE VELOCEMENTE A TUTTE LE FUNZIONI, LA T-1100CX HA 11 USCITE ELETTRICAMENTE OPTOISOLATE CHE POSSONO FUNZIONARE TUTTE CONTEMPORANEAMENTE.. LA POTENZIALITA’ E LA VERSATILITA’ DI QUESTO ELETTROSIMOLATORE SONO UNICHE, CIO’ VIENE EVIDENZIATO DALLA POSSIBILITA’ DI VARIARE TUTTI I PARAMETRI COME: LARGHEZZA D’IMPULSO, FREQUENZA, AZIONE, PAUSAE FORMA D’ONDA. INOLTRE LA T-1100CX PUO’ MEMORIZZARE PROGRAMMI E VISUALIZZARE LA FORMA D’ONDA IN MOVIMENTO DURANTE IL FUNZIONAMENTO SU UN PICCOLO RIQUADRO NEL DISPLAY. L’APPARECCHIATURA HA UNA MEMORIA VIDEO CON TANTE INFORMAZIONI: COME POSIZIONARE GLI ELETTRODI SUI MUSCOLI DEL CORPO E DEL VISO, ALCUNI CONSIGLI PRATICI, DATI TECNICI E TANTO ALTRO. SONO MEMORIZZATI BEN 20 PROGRAMMI SPECIFICI PER OGNI TRATTAMENTO, E PER CIASCUNO IL DISPLAY VISUALIZZA TUTTI I PARAMETRI. ****************************** DISIMBALLAGGIO ! POSIZIONARE LO SCATOLONE CONTENENTE L’APPARECCHIATURA SU UN PIANO. ! ESTRARRE GLI ACCESSORI E SUCCESSIVAMENTE L’APPARATO. ! ASSICURARSI CHE LA DOTAZIONE SIA COMPLETA; 20 ELETTRODI( 45 X 80), 4 (35 X 45), 10 (PG10S), 2 ELETTRODI IN SPUGNA, 2 FASCE BLU, UN CAVO DI RETE, UN CAVO D’USCITA CON CLIPS ROSSE/NERE INFINE IL MANUALE. ! CONSERVARE L’IMBALLO. ************************************ LA GARANZIA E’ VALIDA PER UN ANNO DALLA DATA DI ACQUISTO. ATTENZIONE NON APRIRE L’APPARECCHIATURA POICHE’ UN SISTEMA A FOTOCELLULA RILEVA E MEMORIZZA L’APERTURA. IN QUESTO CASO LA GARANZIA E’ NULLA. QUESTO E’ UN APPARATO PER USO ESCLUSIVAMENTE ESTETICO. PANNELLO DI CONTROLLO F1 , F2 , F3 , F4 , ACCESSO ALLA FUNZIONE RAPPRESENTATA DALL’ICONA.. MANOPOLA CONTRASTO TASTO DI START (AVVIO POWER ON) INVIO (CONFERMA LA SELEZIONE) SPIA VERDE TASTO DI STOP (ARRESTO POWER OFF) RITORNA ALLA PRECEDENTE PAGINA SPIA ROSSA (COPPIA 11) N. B. IN POWER OFF HANNO LA FUNZIONE DI DECREMENTARE O INC. (SPIA ROSSA ACCESA). IN POWER ON, REGOLANO LA CORRENTE DELLA USCITA 11 INCREMENTA IL VALORE DEL REGISTRO SELEZIONATO DECREMENTA IL VALORE DEL REGISTRO SELEZIONATO IN POWER ON LA CORRENTE DELL’ USCITA INDICATA SULLA SERIGRAFIA. LE COPPIE DI TASTI 1-2-3-4-5-6-7-8-9-10-11 REGOLANO LEXAN ANTIGRAFFIO E ANTISOLVENTE S E T U P S E T U P F1 F1 F2 F2 F3 F3 F4 F4 START START STOP STOP ON ON OFF OFF INTENSITY-CONTR INTENSITY-CONTR DEC DEC INC INC S E T U P S E T U P 7 7 8 8 9 9 10 10 11 11 6 6 2 2 3 3 5 5 4 4 1 1 COLOR GRAPHIC DISPLAY COLOR GRAPHIC DISPLAY ATTENTION STATIC SENSITIVE DISPLAY ATTENTION STATIC SENSITIVE DISPLAY BODY BODY FACE FACE IONO IONO T-1100CX T-1100CX HI-TECHNOLOGY HI-TECHNOLOGY 0 0

Transcript of INTRODUZIONE - bios-hitechnologysrl.it · in power on, regolano la corrente della uscita 11...

INTRODUZIONEL’ APPARECCHIATURA T-1100CX E’ UN ELETTROSTIMOLATORE ESTREMAMENTE PROFESSIONALE AD 11 CANALI ED E ’UN PRODOTTO

INTERAMENTE PROGETTATO DALLA DITTA BIOS SNC.PER LA T-1100CX SONO STATE UTILIZZATE LE MIGLIORI TECNOLOGIE ELETTRONICHE, INFATTI E’ INTERAMENTE CONTROLLATA DA UN

MICROPROCESSORE CHE GESTISCE TUTTE LE FASI DELL’ UTILIZZO, ED E’ DOTATA DI UN DISPLAY LCD GRAFICO A 256 COLORI PER VISUALIZZARE CON ESTREMA CHIAREZZA LE INDICAZIONI DI FUNZIONAMENTO.

TRAMITE I 28 TASTI SI PUO’ ACCEDERE VELOCEMENTE A TUTTE LE FUNZIONI, LA T-1100CX HA 11 USCITE ELETTRICAMENTE OPTOISOLATE CHE POSSONO FUNZIONARE TUTTE CONTEMPORANEAMENTE..

LA POTENZIALITA’ E LA VERSATILITA’ DI QUESTO ELETTROSIMOLATORE SONO UNICHE, CIO’ VIENE EVIDENZIATO DALLA POSSIBILITA’ DI VARIARE TUTTI I PARAMETRI COME:

LARGHEZZA D’IMPULSO, FREQUENZA, AZIONE, PAUSAE FORMA D’ONDA.INOLTRE LA T-1100CX PUO’ MEMORIZZARE PROGRAMMI E VISUALIZZARE LA FORMA D’ONDA IN MOVIMENTO DURANTE IL FUNZIONAMENTO

SU UN PICCOLO RIQUADRO NEL DISPLAY.L’APPARECCHIATURA HA UNA MEMORIA VIDEO CON TANTE INFORMAZIONI: COME POSIZIONARE GLI ELETTRODI SUI MUSCOLI DEL CORPO E

DEL VISO, ALCUNI CONSIGLI PRATICI, DATI TECNICI E TANTO ALTRO.SONO MEMORIZZATI BEN 20 PROGRAMMI SPECIFICI PER OGNI TRATTAMENTO, E PER CIASCUNO IL DISPLAY VISUALIZZA TUTTI I PARAMETRI.

******************************

DISIMBALLAGGIO

! POSIZIONARE LO SCATOLONE CONTENENTE L’APPARECCHIATURA SU UN PIANO. ! ESTRARRE GLI ACCESSORI E SUCCESSIVAMENTE L’APPARATO.

! ASSICURARSI CHE LA DOTAZIONE SIA COMPLETA; 20 ELETTRODI( 45 X 80), 4 (35 X 45), 10 (PG10S), 2 ELETTRODI IN SPUGNA, 2 FASCE BLU, UN CAVO DI RETE, UN CAVO D’USCITA CON CLIPS ROSSE/NERE INFINE IL MANUALE.

! CONSERVARE L’IMBALLO.

************************************LA GARANZIA E’ VALIDA PER UN ANNO DALLA DATA DI ACQUISTO.

ATTENZIONE NON APRIRE L’APPARECCHIATURA POICHE’ UN SISTEMA A FOTOCELLULA RILEVA E MEMORIZZA L’APERTURA.IN QUESTO CASO LA GARANZIA E’ NULLA.

QUESTO E’ UN APPARATO PER USO ESCLUSIVAMENTE ESTETICO.

PANNELLO DI CONTROLLO

F1 , F2 , F3 , F4 ,ACCESSO ALLA FUNZIONE RAPPRESENTATADALL’ICONA..

MANOPOLA CONTRASTO

TASTO DI START (AVVIO POWER ON)INVIO (CONFERMA LA SELEZIONE)SPIA VERDE

TASTO DI STOP (ARRESTO POWER OFF)RITORNA ALLA PRECEDENTE PAGINASPIA ROSSA

(COPPIA 11)N. B. IN POWER OFF HANNO LA FUNZIONE DI DECREMENTARE O INC. (SPIA ROSSA ACCESA). IN POWER ON, REGOLANO LA CORRENTE DELLA USCITA 11

INCREMENTA IL VALORE DEL REGISTROSELEZIONATODECREMENTA IL VALORE DEL REGISTROSELEZIONATO

IN POWER ON LA CORRENTE DELL’ USCITA INDICATA SULLA SERIGRAFIA.

LE COPPIE DI TASTI 1-2-3-4-5-6-7-8-9-10-11 REGOLANO

LEXAN ANTIGRAFFIO E ANTISOLVENTE

SETUP

SETUP

F1F1

F2F2

F3F3

F4F4

STARTSTART

STOPSTOP

ONON

OFFOFF

INTENSITY-CONTRINTENSITY-CONTR

DECDEC

INCINCSETUP

SETUP

77 88 99 1010 11116622 33 554411

COLOR GRAPHIC DISPLAYCOLOR GRAPHIC DISPLAY

ATTENTIONSTATIC SENSITIVE

DISPLAY

ATTENTIONSTATIC SENSITIVE

DISPLAY

BODYBODY FACEFACE IONOIONO

T-1100CXT-1100CXHI-TECHNOLOGYHI-TECHNOLOGY 00

RETROPANNELLO

IL RETRO PANNELLO E’ COMPOSTO DA :

1) VASCHETTA PER IL COLLEGAMENTO DEL CAVO DI RETE CHE COMPRENDE UN INTERRUTTORE LUMINOSO VERDE (ON/OFF) E UN’ALLOGGIO PER I DUE FUSIBILI DA 2 AMPERE. N. B. PER ESTRARRE LA VASCHETTA PORTA FUSIBILE E’ NECESSARIO TOGLIERE IL CAVO DI RETE DALL’APPARECCHIATURA, QUINDI TRAMITE UN CACCIAVITE A TAGLIO FARE LEVA SULL’ APPOSITA LINGUETTA IN PLASTICA.

2) CONNETTORE PER IL COLLEGAMENTO DEL CAVO D’USCITA (11 CANALI).

3) ASOLE PER LO SCARICO DELL’ARIA CALDA ; SI RACCOMANDA DI NON OSTACOLARE LO SCARICO.

AVVIAMENTO

1) COLLEGARE IL CAVO DI RETE ALLA LINEA 220V ; LA SPINA MASCHIO TRE POLI ALLA PRESA DI CORRENTE, MENTRE LA SPINA FEMMINA ALL’ APPARECCHIATURA.

2) ACCENDERE L’APPARATO TRAMITE L’INTERRUTTORE GENERALE POSTO NELLA VASCHETTA (ON LUCE VERDE).

3) POSIZIONARE LA MANOPOLA DEL CONTRASTO (INTENSITY-CONTR) SULLO ZERO E ATTENDERE 30 SECONDI CHE LA LUMINOSITA’ GIUNGA A REGIME, SE NECESSARIO RITOCCARE IL CONTRASTO A PROPRIO PIACIMENTO.

4) IL DISPLAY VISUALIZZA LA PRIMA PAGINA (GLOBO).

COMANDI RELATIVI ALLA PRIMA PAGINATASTO F1PREMERE QUESTO TASTO PER ACCEDERE ALLA DESCRIZIONE TECNICA RAPPRESENTATA DALL’ ICONA (COMPUTER), SUCCESSIVAMENTE COL TASTO DEC (COPPIA 11) VIENE VISUALIZZATA LA SECONDA PARTE DELLA PAGINA.PER USCIRE RIPREMERE F1,OPPURE USARE IL TASTO INC PER RIVISUALIZZARE LA PRIMA PARTE.

TASTO F2LA PAGINA VIENE VISUALIZZATA MA NON E’ ATTIVA (PER UNA NORMALE VENDITA).PREMERE F2 PER USCIRE.

TASTO F3LA PAGINA MOSTRA ALCUNI CONSIGLI PRATICI SULL’ UTILIZZO DELL’ APPARECCHIATURA.PREMENDO IL TASTO DEC SI PASSA ALLA SECONDA PARTE DELLA PAGINA.PER USCIRE F3.

TASTO F4VIENE VISUALIZZATO IL CORPO UMANO PER UNA MIGLIORE COMPRENSIONE DI COME POSIZIONARE GLI ELETTRODI IN FUNZIONE DELLEFASCE MUSCOLARI ED ANCHE IL VERSO DI SCANSIONE DEL PROGRAMMA DRENAGGIO.PREMENDO IL TASTO DEC SI PASSA ALLA SOTTO PAGINA CHE MOSTRA ALCUNI CONSIGLI PER L’UTILIZZO DELLE USCITE 9 - 10 SUL VISO.

TASTO STARTCON QUESTO TASTO SI ACCEDE ALLA PAGINA PROGRAMMI.

TASTO STOPNON ATTIVO

TASTI (COPPIE) 1-2-3-4-5-6-7-8-9-10NON ATTIVI

INTERRUTTORE GENERALE LUMINOSO

CAVO DI RETE

SCARICO ARIACONN. D’USCITA

VASC. PORTAFUSUBILI

SPINA DI RETE MASCHIO

CAVO D’USCITA

VASCHETTA DI RETE

SPINA DI RETE FEMMINA

SETUP

SETUP

F1F1

F2F2

F3F3

F4F4

STARTSTART

STOPSTOP

ONON

OFFOFF

INTENSITY-CONTRINTENSITY-CONTR

DECDEC

INCINCSETUP

SETUP

77 88 99 1010 11116622 33 554411

COLOR GRAPHIC DISPLAYCOLOR GRAPHIC DISPLAY

ATTENTIONSTATIC SENSITIVE

DISPLAY

ATTENTIONSTATIC SENSITIVE

DISPLAY

BODYBODY FACEFACE IONOIONO

T-1100CXT-1100CXHI-TECHNOLOGYHI-TECHNOLOGY 00

VARIAZIONE DEI REGISTRI DI UNO SPECIFICO PROGRAMMA

QUESTA OPERAZIONE E’ PER CHI HA CONOSCENZA A RIGUARDO.

PRIMA DI TUTTO E’ NECESSARIO SPIEGARE GLI EFFETTI CHE I REGISTRI HANNO SULLA STIMOLAZIONE.

REGISTRO AZIONENORMALMENTE IL RAPPORTO FRA AZIONE E PAUSA E’ 1:2, CIOE’ UN SECONDO DI AZIONE E DUE DI PAUSA, OPPURE 2 Sec AZ. E 4 Sec di PAUSA.IL REGISTRO ESPRIME IN SECONDI IL TEMPO DI STIMOLAZIONE.

REGISTRO PAUSAIL REGISTRO ESPRIME IN SECONDI IL TEMPO DI NON STIMOLAZIONE.

REGISTRO FREQUENZAQUESTO E’ UN PARAMETRO FONDAMENTALE COME LA LARGHEZZA D’IMPULSO.MAGGIORE E’ LA FREQUENZA, MAGGIORE E’ LA CONTRAZIONE A PARITA’ DI CORRENTE E DI IMPULSO (VALORI NEI LIMITI DELLA RISPOSTAMUSCOLARE).

REGISTRO PULSIL REGISTRO DEFINISCE LA LARGHEZZA DELL’ IMPULSO E COME LA FREQUENZA INCIDE SULLA STIMOLAZIONE.

REGISTRO TIMERSONO TRE I TIMER, CHE IN BASE AL PROGRAMMA VENGONO ABILITATI.I TIMER DUE E TRE SERVONO SOLO PER I PROGRAMMI SPECIALI, CIOE’ QUELLI CHE PREVEDONO TRE FASI DI TRATTAMENTO COME AD ESEMPIO RISCALDAMENTO > STIMOLAZIONE >DRENAGGIO, RISPETTIVAMENTE T1 > T2 > T3.N. B. PER I PROGRAMMI UTENTE I TIMER2 e TIMER3 SONO SEMPRE AZZERATI. IL TIMER DEFINISCE IL TEMPO DI TRATTAMENTO IN MINUTI.

FORMA D’ONDAE’ POSSIBILE MODIFICARLA SOLO SELEZIONANDO UN ALTRO PROGRAMMA.

*******************************************************************************

N. B. I VALORI DEI REGISTRI HANNO DEI LIMITI MASSIMI E MINIMI AFFINCHE’ LA VARIAZIONE DEGLI STESSI NON COMPORTI INDESIDERATIEFFETTI.UN’ ERRATA VARIAZIONE DEI REGISTRI COMPORTERA’ UNA FASTIDIOSA STIMOLAZIONE E SCARSI RISULTATI.NON SI VERIFICHERA’ NESSUN DANNO PER IL FATTO CHE LA POTENZA E’ DISTRIBUITA IN MODO LINEARE, PERTANTO IN QUESTO CASO PREMERE IL TASTO STOP E RISELEZIONARE IL PROGRAMMA CHE AUTOMATICAMENTE SI RISETTERANNO TUTTI I REGISTRI.

DESCRIZIONE SECONDA PAGINA

IN QUESTA PAGINA VENGONO VISUALIZZATI I PROGRAMMI FISSI E QUELLI MEMORIZZATI DALL’ UTENTE (SE MEMORIZZATI).N.B. SE SI SELEZIONA UN PROGRAMMA UTENTE (MEMORIA 1-2-3-4....8 ) UN BIP (SUONO) COSTANTE INDICA CHE LA MEMORIA E’ VUOTA.IL TASTO INC SELEZIONA IL PROGRAMMA MENTRE IL TASTO DEC FA RITORNARE INDIETRO DI UNO STEP.UNA VOLTA SELEZIONATO IL PROGRAMMA EVIDENZIATO IN ROSSO, PREMERE START PER CONFERMARE LA SCELTA E PASSARE ALLA SUCCESSIVA ED ULTIMA PAGINA.PER RITORNARE ALLA SCHERMATA PRECEDENTE PREMERE IL TASTO STOP.

DESCRIZIONE TERZA PAGINA

QUESTA PAGINA E’ FONDAMENTALE.IN BASE AL PROGRAMMA SCELTO, I REGISTRI AZIONE, PAUSA, FREQUENZA, PULS E TIMER VENGONO CARICATI CON SPECIFICI VALORI,QUINDI PIAZZARE GLI ELETTRODI SUI MUSCOLI DA TRATTARE E SUCCESSIVAMENTE AVVIARE IL TRATTAMENTO TENENDO PREMUTO IL TASTOSTART (LA SPIA VERDE LAMPEGGIA POWER ON).LE COPPIE DI TASTI 1- 2 - 3 - 4 - 5 - 6.......11, SERVONO PER INCREMENTARE O DECREMENTARE LA CORRENTE SULLE PLACCHE.SI DOVRA’ PREMERE IL TASTO SUPERIORE DELLA COPPIA 1 PER INCREMENTARE LA POTENZA DELL’ USCITA N°1 OPPURE IL TASTO INFERIOREPER DIMINUIRE LA CORRENTE DELLA STESSA USCITA.L’OPERAZIONE E’ IDENTICA PER TUTTE LE ALTRE USCITE.IMPOSTATE LE POTENZE E’ POSSIBILE AVVIARE IL TIMER RIPREMENDO IL TASTO START .(LA SPIA VERDE E’ SEMPRE ACCESA)PER ARRESTARE MOMENTANEAMENTE IL TRATTAMENTO PREMERE IL TASTO STOP (LA SPIA ROSSA LAMPEGGIA), RIPREMENDO IL TASTO STOPSI ARRESTA IL TRATTAMENTO (LA SPIA ROSSA E’ SEMPRE ACCESA) , QUINDI SE NECESSARIO TOGLIERE GLI ELETTRODI.RIPREMENDO NUOVAMENTE IL TASTO STOP SI RITORNA ALLA VIDEATA PRECEDENTE.NEL CASO CHE L’UTENTE VUOLE VARIARE DEI PARAMETRI E’ NECESSARIO CHE LA SPIA ROSSA DI STOP SIA SEMPRE ACCESA (APPARATO IN STOP, POWER OFF).

20

20

40 2000 0 2

0 0

1) ALTERNATA2) DIADINAMICA MF

3) DIADINAMICA DF4) ESPONENZIALE5) RIABILITAZIONE

6) ANALGESICO7) TEST MUSCOLARE8) LINFODRENAGGIO

9) KOTZ

10) INTERFERENZIALE11) RASSODANTE12) LIPOLISI13) RELAX14) GLUTEI

15) PETTORALI16) MOD. VISO

17) ATLETICA18) SCI

19) TENNIS20) CICLISMO

MEMORIA 7

MEMORIA 5

MEMORIA 8

MEMORIA 2 MEMORIA 1

MEMORIA 3 MEMORIA 4

MEMORIA 6

DECDEC

INCINCSETUP

SETUP

1111

IONOIONO

INTERFERENZIALE

COMANDI RELATIVI ALLA TERZA PAGINATASTO F1 COLORE AZZURROPER OGNI PRESSIONE SUL TASTO LA SELEZIONE SARA’ RISPETTIVAMENTE AZIONE>PAUSA>FREQUENZA>PULS,, QUINDI SI RIPETE IL CICLO.USANDO I TASTI INC/DEC SI VARIA IL REGISTRO SELEZIONATO.PER USCIRE E’ SUFFICIENTE PREMERE UN’ALTRO TASTO RELATIVO ALLA FUNZIONE DA ACCEDERE, PUO ESSERE ANCHE LO START.N. B. PER RITORNARE ALLA PAGINA PRECEDENTE E’ NECESSARIO CHE IL CURSORE NON LAMPEGGI SU NESSUNA POSIZIONE.PER OTTENERE QUESTO PREMERE E RILASCIARE VELOCEMENTE UNO DEI QUATTRO TASTI (F1-F2-F3-F4) CHE NON SIA QUELLO DELLAFUNZIONE ATTUALE. (Es1. SE IL CURSORE LAMPEGGIA SU AZIONE PREMERE F2 O F3 OPPURE F4). ( Es2. SE IL CURSORE LAMPEGGIA SU PROGRAMMA PREMERE F1 O F2 OPPURE F4).

TASTO F2 COLORE GIALLOPREMENDO QUESTO TASTO SI REGOLA TIMER1,RIPETENDO L’OPERAZIONE SI ACCEDE AL TIMER2, QUINDI AL TIMER3.PER AUMENTARE O DIMINUIRE IL TEMPO USARE I TASTI INC/DEC.

TASTO F3 COLORE MAGENTA CON QUESTO TASTO SI ACCEDE ALLA SELEZIONE DEL PROGRAMMA .USARE I TASTI INC/DEC PER SCORRERE NELLA SELEZIONE.

TASTO F4 COLORE NEROIL TASTO MEMORIZZA L’ATTUALE PROGRAMMA IN UNA DELLE OTTO POSIZIONI DI MEMORIA.QUESTA FUNZIONE VIENE UTILIZZATA SE L’UTENTE HA LA NECESSITA’ DI VARIARE UN PROGRAMMA, QUINDI PER POTERLO RILEGGERE IN UN SECONDO MOMENTO DOVRA’ MEMORIZZARLO.UNA VOLTA MODIFICATO IL PROGRAMMA PREMERE IL TASTO F4 , ORA NELLA CASELLA CHE INDICAVA IL NOME DEL PROGRAMMA COMPARE LA SCRITTA (MEMORIZZA 01), USARE I TASTI INC/ DEC PER SELEZIONARE UNA LOCAZIONE DI MEMORIA VUOTA (ES 01-02-03....08)QUINDI RIPREMERE IL TASTO PER CONFERMARE LA MEMORIZZAZIONE.

TASTO START COLORE VERDE (AVVIAMENTO APPARATO)TENERE PREMUTO IL TASTO FINCHE’ LA SPIA VERDE SI ACCENDE, A QUESTO PUNTO L’ APPARECCHIO E’ IN GRADO DI EROGARE CORRENTE.

TASTO STOP COLORE ROSSOQUANDO L’APPARECCHIATURA E’ IN POWER ON, PREMENDO IL TASTO SI ARRESTA L’EROGAZIONE DELLA CORRENTE, (PER RIPRENDERE IL TRATTAMENTO PREMERE IL TASTO START) CON UN’ALTRA PRESSIONE SUL TASTO SI RITORNA ALLA PAGINA PRECEDENTE.

DESCRIZIONE PROGRAMMI (PARTE TECNICA)

PROGRAMMA 1 ONDA ALTERNATA SINUSOIDALE - APPLICAZIONE SOLO CORPO, NO VISO. SINC-FRQ REGISTRI NON VARIABILI >PULSPROGRAMMA 2 ONDA DIADINAMICA MONOFASE 50Hz - APPLICAZIONE SOLO CORPO, NO VISO. SINC-FRQ REGISTRI NON VARIABILI >PULS PROGRAMMA 3 ONDA DIADINAMICA DIFASE 100Hz- APPLICAZIONE SOLO CORPO, NO VISO. SINC-FRQ REGISTRI NON VARIABILI >PULSPROGRAMMA 4 ONDA ESPONENZIALE CON PICCO NEGATIVO, SOLO CORPO, NO VISO. SINC-AZ REGISTRI NON VARIABILI >PULSPROGRAMMA 5 ONDA QUADRA CRESCENTE. MODULATA CON FREQUENZA AD IMPULSI POSITIVI E NEGATIVI. SINC-AZ .PROGRAMMA 6 ANTIDOLORIFICO T.E.N.S. SINC-FRQ.PROGRAMMA 7 ONDA QUADRA PER IL RILEVAMENTO DEL PUNTO DOVE PIAZZARE L’ELETTRODO, REGOLARE LA POTENZA A META’ VERDE.PROGRAMMA 8 LE USCITE VANNO IN SCANSIONE. ES. FASE1>OUT1/OUT2 FASE2>OUT3/OUT4 FASE3>OUT5/OUT6 FASE4>OUT7/OUT8.PROGRAMMA 9 ONDA QUADRA AD ALTA FREQUENZA PER FORZA ESPLOSIVA, NO VISO. SINC-FRQ. PROGRAMMA 10 ONDA INTERFERENZIALE MODULATA SINUSOIDALE A BASSA FREQUENZA. PORTANTE ONDA QUADRA ALTA FREQUENZA. SINC-AZ.PROGRAMMA 11 ONDA QUADRA PER IL RASSODAMENTO. SINC-FRQ. PROGRAMMA 12 ONDA QUADRA A BASSA FREQUENZA SENZA PAUSA. EFFETTO ELETTROLIPOLISI PER PARTI GRASSE. SINC-FRQ. PROGRAMMA 13 ONDA QUADRA A BASSA FREQUENZA. EFFETTO RELAX. SINC-FRQPROGRAMMA 14 ONDA QUADRA CRESCENTE, MODULATA A 40Hz/2,8mS PER RASSODAMENTO GLUTEI. SINC-AZ PROGRAMMA 15 ONDA QUADRA AD ALTO RITMO AZIONE/PAUSA. SINC-FRQ.PROGRAMMA 16 ONDA SPECIFICA PER STIMOLAZIONE VISO. NON ADATTA PER CORPO. SINC-FRQ.PROGRAMMA 17 PROGRAMMA SPECIALE A TRE FASI RISCALDAMENTO MUSCOLI>FORZA ESPLOSIVA>DRENAGGIO PER SCARICARE I MUSCOLI. E’ NECESSARIO COLLEGARE TUTTE LE OTTO USCITE. SINC-FRQ.PROGRAMMA 18 PROGRAMMA SPECIALE A TRE FASI RISCALDAMENTO MUSCOLI>FORZA ESPLOSIVA>DRENAGGIO PER SCARICARE I MUSCOLI. E’ NECESSARIO COLLEGARE TUTTE LE OTTO USCITE. SINC-FRQ.PROGRAMMA 19 PROGRAMMA SPECIALE A TRE FASI RISCALDAMENTO MUSCOLI>FORZA ESPLOSIVA>DRENAGGIO PER SCARICARE I MUSCOLI. E’ NECESSARIO COLLEGARE TUTTE LE OTTO USCITE. SINC-FRQ.PROGRAMMA 20 PROGRAMMA SPECIALE A TRE FASI RISCALDAMENTO MUSCOLI>FORZA ESPLOSIVA>DRENAGGIO PER SCARICARE I MUSCOLI. E’ NECESSARIO COLLEGARE TUTTE LE OTTO USCITE. SINC-FRQ.

N. B. LA SIGLA (SINC-AZ) INDICA CHE LA GENERAZIONE DELLA FORMA D’ONDA DIPENDE DAL TEMPO DI AZIONE. ES. AZ=0,4 Sec L’ONDA SI SVILUPPERA’ ENTRO QUEL TEMPO. QUESTO CONSENTE DI AVERE ONDE A LENTA CRESCITA.

N. B. LA SIGLA (SINC-FRQ) INDICA CHE LA GENERAZIONE DELLA FORMA D’ONDA DIPENDE DAL VALORE DELLA FREQUENZA (ES. FRQ = 50Hz) SVILUPPERA’ ENTRO QUEL TEMPO . T=1/F

N. B. SE NON E’ SPECIFICATA L’APPLICAZIONE SI INTENDE CHE L’ONDA PUO’ ESSERE UTILIZZATA PER IL VISO E CORPO.

N. B. TUTTE LE FORME D’ONDA TRANNE LE DIADINAMICHE SONO CON IMPULSI POSITIVI E NEGATIVI.

N. B. TUTTI I REGISTRI SE NON SPECIFICATI SONO VARIABILI.

TRATTAMENTO - ESTETICO/SPORTIVO ONDA PROG FIG.

TONIFICAZIONE MUSCOLI PETTORALI

TONIFICAZIONE MUSCOLI DORSALI

TONIFICAZIONE ADDOMINALE PROFONDA

TONIFICAZIONE MUSCOLI LOMBARI

POTENZIAMENTO ADDOMINALI

POTENZIAMENTO MUSCOLI BICIPITI

POTENZIAMENTO MUSCOLO AVAMBRACCIO

POTENZIAMENTO MUSCOLO DEL POLPACCIO

POTENZIAMENTO MUSCOLI QUADRICIPITI

POTENZIAMENTO GENERALE CORPO

DIMAGRIMENTO BRACCIA

DIMAGRIMENTO PANCIA - VITA - FIANCHI

DIMAGRIMENTO COSCIA INT./ EST. - GINOCCHIO

DIMAGRIMENTO POLPACCI

DIMAGRIMENTO GLUTEI

DIMAGRIMENTO UNIVERSALE INTENSIVO CORPO

PELLE A BUCCIA D’ARANCIA MEDIA

PELLE A BUCCIA D’ARANCIA PROFONDA

TRATTAMENTO SPORTIVO A TRE FASI RISCALD.- POTENZ - DREN

TRATTAMENTO LINFODRENANTE

TRATTAMENTO VISO

TONIFICAZIONE SENO

TONIFICAZIONE ADDOME

TONIFICAZIONE BRACCIA

TONIFICAZIONE SPALLE

TONIFICAZIONE GLUTEI

TONIFICAZIONE INTERNO COSCE

TONIFICAZIONE ESTERNO COSCE

TONIFICAZIONE GENERALE CORPO

QUADRA BIFASICA A SCANSIONE

QUADRA BIFASICA

QUADRA BIFASICA

QUADRA BIFASICA

INTERFERENZIALE/SIN. MODULATA H/FRQ

QUADRA BIFASICA

QUADRA BIFASICA-CRESCENTE-MODULATA

INTERFERENZIALE/SIN. MODULATA H/FRQ

INTERFERENZIALE/SIN. MODULATA H/FRQ

QUADRA BIFASICA

QUADRA BIFASICA AD ALTO RITMO

INTERFERENZIALE SINUSOIDALE MOD.

KOTZ QUADRA BIFASICA AD ALTA FREQUE-ZA 2500HZ.INTERFERENZIALE

KOTZ 2500 HZ

KOTZ 2500 HZ

KOTZ 2500 HZ

KOTZ 2500 HZ

KOTZ 2500 HZ

KOTZ 2500 HZ

QUADRA BIFASICA 30HZ LIPOLISI

QUADRA BIFASICA 30HZ LIPOLISI

QUADRA BIFASICA 30HZ LIPOLISI

QUADRA BIFASICA 30HZ LIPOLISI

QUADRA BIFASICA 30HZ LIPOLISI

QUADRA BIFASICA 30HZ LIPOLISI

QUADRA BIFASICA 30HZ LIPOLISI

QUADRA BIFASICA 30HZ LIPOLISI

BIFASICA BF --> AF KOTZ ---> BIFASICAA 250HZ

N°8

N°16

N°11

N°11

N°10

N°11

N°14

N°10

N°10

N°11

N°15

N°10

N°9

N°10

N°9

N°9

N°9

N°9

N°9

N°9

N°12

N°12

N°12

N°12

N°12

N°12

N°12

N°12

N°17-18-19-20

FIG. 4

FIG. 2

FIG. 2

FIG. 2

FIG. 1-2

FIG. 1

FIG. 1

FIG. 2

FIG. 2

FIG. 1-2

FIG. 8

FIG. 6

FIG. 8

FIG. 5

FIG. 8

FIG. 7

FIG. 7

FIG. 6

FIG. 7

FIG. 7-8

FIG. 1

FIG. 2

FIG. 2

FIG. 1

FIG. 1

FIG. 1-2

UTENTE-

UTENTE-

FIG. 9-10

m. sternocleidomastoide

m. deltoide

m. serrato anteriore

m. bicipite

m. bracoradiale

m. estensoreradiale corto

m. adduttorelungo

m. recto femorale

m. soleo

m. flessore lungo

m. vasto laterale

m. pettoralimaggiori

m. rectoaddominale

m. obliquoaddominaleesterno

m. gracile

m. sartorio

m. vasto mediale

m. gastrocnemio

m. tibia anteriore

m. estensore lungo

POSIZIONARE GLI ELETTRODI SEMPRE ALLE ESTREMITA’ DEL MUSCOLO (FASCIA MUSCOLARE).SE LE DIMENSIONI DEL MUSCOLO SONO PIU’ GROSSE DELL’ELETTRODO

AGGIUNGERE UN’ALTRA USCITA.

TRATTAMENTO - BENESSERE ONDA PROG FIG.

ANALGESIA - ANTIDOLORIFICO - T.E.N.S.

RIABILITAZIONE MUSCOLARE - MUSCOLO DENERVATO

TORCICOLLO

TENDINITE

DISTORSIONE

CERVICALGIA

FORTE EFFETTO ANALGESICO - DOLORI ACUTI

ONDA QUADRA CON PICCO NEGATIVO

ONDA QUADRA CRESCENTE MODULATABIFASICA A LENTA CRESCITA.ESPONENZIALE CON PICCO NEGATIVO

ONDA QUADRA CON PICCO NEGATIVO

ONDA QUADRA CRESCENTE

DIADINAMICA MONOFASE SINUSOIDALE50HZ.DIADINAMICA DIFASE SINUSOIDALE 100HZ

N°6

N°5

N°4

N°6

N°5

N°2

N°3

UTENTE

UTENTE

FIG. A

UTENTE

UTENTE

FIG. A

UTENTE

1

1

2

2

CERVICALE - TORCICOLLO

STESSO NUMERO STESSA USCITA

3

34

4

FIG A

PIAZZARE GLI ELETTRODI COME NELLE DUE FIGURE QUI’ SOTTOPER I TRATTAMENTI DI TORCICOLLO E CERVICALGIA.

POSIZIONARE GLI ELETTRODI SEMPRE ALLE ESTREMITA’ DEL MUSCOLO (FASCIA MUSCOLARE).SE LE DIMENSIONI DEL MUSCOLO SONO PIU’ GROSSE DELL’ELETTRODO

AGGIUNGERE UN’ALTRA USCITA.

ESEMPIO

1 1

1 1

PRENDERE VISIONE DELLE FASCIE MUSCOLARI

I SETTORI INDICANO IL TRATTAMENTO SIMULTANEO CHE SI PUO’ FARE IN UNA SOLA SEDUTA. (DIPENDE DAL NUMERO DELLE USCITE DISPONIBILI).

TRATTAMENTOBRACCIA

TRATTAMENTO SPALLE

TRATTAMENTO GLUTEI

POSIZIONE DEGLI ELETTRODIDA ASSOCIARE ALLA TONIFICAZIONE

GLUTEI

1

1

2

2

3

34

45

5

7

7

8

8

9

9

10

10

TRAT

TAM

ENTO

POL

PACC

IO

TRAT

TAM

ENTO

POL

PACC

IO 1

1

2

2

SETTORE A

SETTORE B

TRATTAMENTOBRACCIA

6

6

1

1

2

2

3

3

4 5 6

654

8

8

9

9

1

1

2

2

3

3

4

4

10

109

9

TRATTAMENTO DEL SENO

PER IL TRATTAMENTO VISOUSARE LE USCITE 9-10

TRATTAMENTO VISO

MUSCOLI BICIPITIM

USCO

LI B

ICIP

ITI

TRATTAMENTO PANCIA MUSCOLI ADDOMINALI

ELETTRODOPg10

7

7

10

10

MUSCOLO AVAMBRACCIOMUS

COLO

AVA

MBR

ACCI

O

INTE

RNO

COS

CIA

INTE

RNO

COS

CIA

ESTE

RNO

COSC

IA

ESTE

RNO

COSC

IA

SETTORE A

SETTORE B

SETTORE C

FIG 1 FIG 2

5

5

Uscita numero 5 (N.B. gli elettrodi con lo stesso numerosi riferiscono alla stessa uscita)

ESEMPIO

TRATTAMENTO VISO

PIAZZARE GLI ELETTRODIIN MODO SIMMETRICO NELLATO OPPOSTO

1

1

2

2

3

3

4

4

TRATTAMENTO FIANCHI

TRATTAMENTO ESTERNO COSCIA

1

1

3

3

2

2

4

4

5

5

6

6

7

7 8

8

TRATTAMENTO LINFODRENAGGIO

PER QUESTO TRATTAMENTO E’ NECESSARIO RISPETTARE LAPOSIZIONE DEGLI ELETTRODI/N°USCITA COME IN FIG 4.

VER

SO D

I SC

ANSI

ONE

DEL

LE U

SCIT

E

FIG 3 FIG 4

COME POSIZIONARE GLI ELETTRODI

Muscoli del trapezio

Muscoli d

el trapezio

Muscoli del trapezio Muscoli del trapezio

1

1

2

2

3

3

4

4

Mus

colo

lom

bare

5 5

6

7 7

8

6

8

9

9 10

10

Mus

colo

trip

ipite

Muscolo tripipite

Muscolo gran dorsale

1

1 2

23 4

43

7

7

8

8

9 9 1010

5

5 6

6

FIG5 FIG6

COME POSIZIONERE GLI ELETTRODI

TRATTAMENTO PETTORALI

TRATTAMENTO ADDOMINALIFIANCHIFIANCHI

SPALLAMUSCOLO DELTOIDEO

SPALLAMUSCOLO DELTOIDEO

1

1

3

3

2

2

4

4

5

5 6

6

7

7

8

89

910

10

TRATTAMENTO MUSCOLO QUADRICIPITE FEMORALE

MUSCOLO TIBIALE ANTERIOREMUSCOLO TIBIALE ANTERIORE

1

1

2

2

3

3

4

4 5

5

6

6

7

7

8

8

9

9

10

10 MUSCOLO BICIPITEM

USCO

LO B

ICIP

ITE

TRATTAMENTOAVAMBRACCIO

TRATTAMENTOAVAMBRACCIO

FIG 7 FIG 8

COME POSIZIONARE GLI ELETTRODI

1

1

2

2

3

3

5

5 6

6

4

4

7

7 8

8

9

9

10

10

9

9

7 8

87

1

5

5

3

3

4

4

TRATTAMENTO DEL SENO

TRATTAMENTO PETTORALI

TRATTAMENTO PANCIA MUSCOLI ADDOMINALI

TRATTAMENTO PANCIA MUSCOLI ADDOMINALI

INTE

RNO

COS

CIA

INTE

RNO

COS

CIA

ESTE

RNO

COSC

IA

ESTE

RNO

COSC

IA

1

2

2

6

6

10

10

POSIZIONE DEGLI ELETTRODI DA USARE CON I PROGRAMMI SPECIALI 17-18-19-20.

N. B. NELLA FASE DI RISCALDAMENTO NON SUPERARE IL COLORE VERDE COME VALORE DI POTENZA..

N. B. MENTRE VIENE ESEGUITO IL DRENAGGIO A SCANSIONE ( USCITE 1--->8) LE USCITE 9-10 SVOLGONO UN LAVORO INDIPENDENTE.QUESTE ULTIME USCITE HANNO LA FUNZIONE DI TONIFICARE COSTANTEMENTE I MUSCOLI PETTORALI ,IL SENO O ALTRO .

FIG9 FIG10

PER QUESTO TRATTAMENTO E’ NECESSARIO RISPETTARE LA POSIZIONE DEGLI ELETTRODI/N°USCITA(1 --- 8 ) COME IN FIGURA.LE USCITE 9-10 SONO A DISPOSIZIONE DELL’UTENTE PER IL TRATTAMENTO DI ALTRI MUSCOLI.( ES. PER UN SCIATORE E’ BENE POTENZIARE LA GAMBA INVECE DEI PETTORALI )

ALTRI ESEMPI DI COME PIAZZARE GLI ELETTRODI

UOMO DONNA

IL COLLEGAMENTO SULLA PLACCA DELLA CLIP ROSSA (+ POSITIVO) O NERA (- NEGATIVO) E’ INDIFFERENTE PER IL MOTIVO CHE GLI IMPULSI SONO POSITIVI E NEGATIVI.

N.B. SOLO PER I PROGRAMMI 2, 3, 4 E PER LA IONO (OUT 11) E’ IMPORTANTE IL VERSO DELLA CORRENTE, PER IL FATTO CHE LE ONDE NON SONO ALTERNATE. N.B. PER IL COLLEGAMENTO DEGLI ELETTRODI SUL VISO LE INDICAZIONI SONO CONTENUTE NELLA MEMORIA VIDEO DELL’APPARECCHIATURA. IL CONSIGLIO E’ DI TENERE GLI ELETTRODI DISTANTI DAGLI OCCHI, QUESTO PER EVITARE UN FASTIDIOSO TRATTAMENTO.

UTILIZZARE IL PROGRAMMA SPECIFICO PER IL VISO.

USARE CAUTELA NELL’ AUMENTARE LA POTENZA.

E’ PREFERIBILE RICERCARE IN MODO OTTIMALE LA POSIZIONE DELLE PLACCHE.

PROG. 16

USARE L’ ELETTRODO ROTONDO DI PICCOLE DIMENSIONI.

USARE LA PLACCA PIU’ GROSSA SE POSSIBILE (45 X 80).

MODALITA’ VISO

ALCUNI ESEMPI DI COME PIAZZARE GLI ELETTRODI UTILIZZANDO LA IONOFORESI (OUT 11)

CONTROINDICAZIONI

ATTENZIONI GENERALI DELL’ ELETTROSTIMOLAZIONE

LE CONTROINDICAZIONI DELLA T-1100CX SONO POCHE E SPESSO SOLO INDICATE PER MOTIVI PRECAUZIONALI.SI SCONSIGLIA DI SOTTOPORRE A TRATTAMENTO PAZIENTI CON:

/ORGANI AUSILIARI ELETTRONICI COME STIMOLATORI CARDIACI E PACEMAKER

/EVENTUALI APPARECCHI ACUSTICI NON VANNO PORTATI DURANTE IL TRATTAMENTO

/PROTESI METALLICHE O MIO ELETTRICHE

/INSUFFICENZA CORONARICA

/DISTURBI EMATOLOGICI (ANEMIA, LEUCOSI, ECC)

/STATI EMORRAGICI DI QUALSIASI TIPO

/GRAVI MALATTIE DEI VASI

/TROMBOFLEBITI

/DISTURBI PSICHICI

/SINDROME PSICOSOMATICA

/EPILESSIA

/MALATTIE INFETTIVE CON STATI FEBBRILI DI ORIGINE BATTERICA O VIRALE

/MICOSI

/IPERFUNZIONE TIROIDEA

/SINDROMI ENDOCRINE

/TUBERCOLOSI

/INSUFFICIENZA EPATICA

/INSUFFICIENZA RENALE

/DIABETE GIVALILE

/GRAVIDANZA

/EVITARE DI INTERPORRE IL CUORE TRA GLI ELETTRODI O POSIZIONARE QUESTI NELL’AREA CARDIACA, SPECIE SE IN PRESENZA DI CARDIOPATIA O ALTERAZIONE DEL RITMO CARDIACO.

/EVITARE DI STIMOLARE L’AREA DEL SENO CAROTIDEO IN QUANTO IN ALCUNI SOGGETTI L’AREA HA UN’ALTA SENSIBILITA’ RIFLESSA E SI POTREBBERO SCATENARE ARITMIE.

/EVITARE LA STIMOLAZIONE SULLA SUPERFICIE ANTERIORE DEL COLLO PER NON SCATENARE EVENTUALI SPASMI DELLA LARINGE O FARINGE.

/VA EVITATA IN ZONE VICINO AGLI OCCHI E SULLE MUCOSE.

LA MAGGIOR PARTE DI QUESTE CONTROINDICAZIONI E’ BASATA SUL FATTO CHE NON ESISTONO CASISTICHE DI PAZIENTI TRATTATI CONTALI AFFEZIONI E SONO PERCIO’ SCONOSCIUTE LE REAZIONI DEI CAMPI ELETTRICI.IN OGNI CASO IN PRESENZA DI SINTOMATOLOGIE NON DEFINITE, O NEL DUBBIO, SI CONSIGLIA DI CONSULTARE IL PROPRIO MEDICODI FIDUCIA O FISIATRA PRIMA DI USARE L’APPARECCHIATURA.

PRECAUZIONI DURANTE UN TRATTAMENTO- DURANTE UN TRATTAMENTO NON SPOSTARE NE RIMUOVERE NESSUN ELETTRODO.- NON INTERROMPERE IL TRATTAMENTO USANDO L’INTERRUTTORE GENERALE(SOLO IN CASO DI EMERGENZA), MA USARE IL TASTO ROSSO DI STOP.- AUMENTARE CON MODERAZIONE LA CORRENTE. SE L’APPARATO STA ESEGUENDO LA PAUSA NON VI E’ NESSUNA STIMOLAZIONE.- EVITARE DI SUPERARE LA SOGLIA GIALLA DI POTENZA , EVENTUALMENTE CERCARE DI PIAZZARE IN MODO OTTIMALE L’ELETTRODO.- EVITARE DI COLLEGARE NELLA STESSA PRESA DI CORRENTE APPARATI CON GROSSI ASSORBIMENTI (ES. SUPERIORI A 200W).- EVITARE ASSOLUTAMENTE DI PULIRE L’APPARECCHIATURA QUANDO E’ ACCESA (EVITARE DI PRODURRE CARICHE ELETTROSTATICHE) .

PRECAUZIONI GENERALI- PULIRE L’APPARECCHIATURA CON UN PANNO UMIDO , LA MACCHINA DEVE ESSERE SCOLLEGATA DALLA PRESA DI RETE.- NON FARE PRESSIONE SULLA PARTE TRASPARENTE DEL DISPLAY.- PREMERE I TASTI CON MODERAZIONE, SI EVITERA’ DI DANNEGGIARLI IN MODO IRREPARABILE.- NON INTRODURRE OGGETTI NELLO SCARICO DELL’ARIA.- ESTRARRE IL CAVO PRENDENDOLO PER IL CONNETTORE. QUESTO PER EVITARE DI ROMPERE I COLLEGAMENTI INTERNI DELLO STESSO CAVO.- PER SOSTITUIRE I FUSIBILI DA 2 AMPERE USARE MOLTA CAUTELA. QUESTA OPERAZIONE DEVE ESSERE FATTA CON IL CAVO DI RETE STACCATO. SE NON SI E’ SICURI DI COME FARE LA SOSTITUZIONE SERVIRSI DI UNA PERSONA COMPETENTE. (ASSISTENZA/RIPARAZIONI -ELETTRONICHE)

EVENTUALI PROBLEMIPOWER ON, MA L’USCITA NON DA CORRENTE - AUMENTARE LA POTENZA. (SOGLIA DI STIMOLAZIONE)- IL CAVO D’USCITA NON E’ COLLEGATO.- L’USCITA SELEZIONATA SUL DISPLAY NON E’ QUELLA COLLEGATA AL MUSCOLO.- GLI ELETTRODI SONO DA SOSTITUIRE.

DISPLAY- IL DISPLAY E’ TROPPO SCURO/LUMINOSO, REGOLARE IL CONTRASTO.- IL DISPLAY VISUALIZZA CARATTERI O PIXEL CHE NORMALMENTE NON CI SONO, PREMERE IL TASTO STOP OPPURE SPEGNERE E RIACCENDERE L’APPARATO.- IL DISPLAY E’ MOLTO CHIARO NELLA PARTE ALTA. CONTROLLARE L’EFFICIENZA DELLO SCARICO DELL’ ARIA CALDA. NON OSTACOLARE IL FLUSSO.

LA STIMOLAZIONE E’ FASTIDIOSA- LA POSIZIONE DELL’ ELETTRODO NON E’ GIUSTA.- L’ELETTRODO NON TOCCA IN TUTTA LA SUA SUPERFICIE.- L’ELETTRODO E’ DA SOSTITUIRE.

IL CONNETTORE NON SI INSERISCE- VERIFICARE IL VERSO DI INSERIMENTO. SIA IL CAVO DI RETE CHE QUELLO D’USCITA HANNO PRECISE GUIDE D’INNESTO.

CARATTERISTICHE TECNICHE!

! ALIMENTAZIONE DI RETE 220V-50HZ - 50W - FUSIBILI 2 AMPERE! GENERATORE SWITCHING PER ALIMENTAZIONE MODULI D’USCITA. ! 8 USCITE CORPO DA 120mA DI PICCO OPTOISOLATE.! 2 USCITE VISO DA 30mA DI PICCO OPTOISOLATE.! 1 USCITA A CORRENTE CONTINUA DA 10mA MAX (LIMITAZIONE HARDWARE).! TUTTE LE USCITE SONO CON GENERATORE A CORRENTE COSTANTE.

! DISPLAY GRAFICO RGB A 256 COLORI (MAX 4096) 320X240 DOTS.! CONTROLLER VIDEO EPSON 80KBYTE SRAM.! MEMORIA VIDEO DI SERIE 8MBYTE, ESPANDIBILE 16MBYTE (EPROM).! MICROCONTROLLER PIC 16F876 - 20 MHz.! FRONTALE CON 28 TASTI PER UN FACILE ACCESSO A TUTTE LE FUNZIONI.! 3 TIMER PER TRE FASI DI TRATTAMENTO, TUTTI REGOLABILI DA 0-99 MINUTI.! PARAMETRO AZIONE VARIABILE DA 0,1 Sec. A 9,9 Sec.! PARAMETRO PAUSA VARIABILE DA 0 Sec. A 9,9 Sec.! PARAMETRO FREQUENZA VARIABILE DA 1 Hz A 2000 Hz (AUTOCONTROLLATO IN RELAZIONE ALLA LARGHEZZA DELL’IMPULSO).! PARAMETRO LARGHEZZA IMPULSO VARIABILE DA 100 µS A 2,8 mS.! 20 PROGRAMMI SPECIFICI PER OGNI TRATTAMENTO: VISO, CORPO, SPORT, BENESSERE, RILASSAMENTO, DRENAGGIO A 8 USCITE,

FORZA ESPLOSIVA, LIPOLISI, TENS, KOTZ, INTERFERENZIALI. ! POSSIBILITA’ DI CREARE 8 PROGRAMMI E MEMORIZZARLI (SOLO PER PROFESSIONISTI).! TIPO DI ONDE: RETTANGOLARI, ESPONENZIALI, SINUSOIDALI RAMPE A VELOCITA’ VARIABILE, TRIANGOLARI, DIADINAMICHE MONOFASI E

DIFASI (LE ONDE SONO MODULATE IN FREQUENZA, AMPIEZZA E IN TENSIONE, CON LA POSSIBILITA’ DI POTER VARIARE QUALSIASI PARAMETRO).

! PESO 3,8Kg - ALTEZZA 12cm - LARGHEZZA 31cm - PROFONDITA’ 30cm.

DISPOSITIVO ESCLUSIVAMENTE PER USO ESTETICO, CONFORME ALLE NORMATIVE RIGUARDANTE GLI APPARATI ELETTROESTETICI.

BIOS snc via Padre Massimiliano Kolbe n° 67 61100 Pesaro ITALY Tel 0721 - 370666 Fax 0721 - 378077www.bios-snc.it