Artemide inc. 250, Karin Lane, Hicksville (NY) 11801 T. +1 631 694 9292 | [email protected] | www.artemide.net Artemide Ltd. 11105, rue Renaude Lapointe, Montréal (QC) H1J 2T4 T. +1 514 323 6537 | [email protected] | www.artemide.net 1 37 CUBE LOW VOLTAGE Assembly instructions Y503-11528 rev 0.1 Attention: Read and understand these instructions before installing fixture. This fixture is intended for installation in accordance with National Electric Code and local regulation: To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. This equipment is guaranteed only when used as indicated in these instructions; therefore they should be kept for future reference. To prevent electrical shock, turn off power supply before carrying out any connection or maintenance operations. Your box should contain ;complete fixture STEP 1 1. Cut a circular opening in the ceiling STEP 2 1. Unscrew junction box cover and remove. STEP 2A For Low-volatage wires : 1. Pass wire through bushing. 2. pass inside strain relief and tighten the screws STEP 3 1. Make appropriate con- nections. 2. Screw junction box cover back. STEP 2B For BX conduit or Loomex wires : 1. Remove bushing, screws and strain relief bracket 2. Install BX conduit or loomex connector (not included). 3.1 D D = 2 1/4’’ 5.7 cm 2.1 2B.1 2A.1 2A.2 FIXTURE WIRES CEILING WIRES Black White White + Black - strain relief bracket 2B.2 This luminaire is compatible with 12 Volts AC or DC circuits.

Transcript of 37 CUBE LOW VOLTAGE - Artemide North America...Artemide inc. 250, Karin Lane, Hicksville (NY) 11801...

  • Artemide inc.250, Karin Lane, Hicksville (NY) 11801T. +1 631 694 9292 | [email protected] | www.artemide.net

    Artemide Ltd.11105, rue Renaude Lapointe, Montréal (QC) H1J 2T4

    T. +1 514 323 6537 | [email protected] | www.artemide.net1

    37 CUBELOW VOLTAGE Assembly instructions

    Y503-11528rev 0.1

    Attention: Read and understand these instructions before installing fixture. This fixture is intended for installation in accordance with National Electric Code and local regulation: To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. This equipment is guaranteed only when used as indicated in these instructions; therefore they should be kept for future reference. To prevent electrical shock, turn off power supply before carrying out any connection or maintenance operations.

    Your box should contain ;complete fixture STEP 1 1. Cut a circular opening in the ceiling

    STEP 2 1. Unscrew junction box cover and remove.

    STEP 2A For Low-volatage wires :

    1. Pass wire through bushing.2. pass inside strain relief and tighten the screws

    STEP 3 1. Make appropriate con-nections.

    2. Screw junction box cover back.

    STEP 2B For BX conduit or Loomex wires :

    1. Remove bushing, screws and strain relief bracket2. Install BX conduit or loomex connector (not included).

    3.1

    D D = 2 1/4’’

    5.7 cm

    2.1

    2B.1

    2A.1

    2A.2

    FIXTUREWIRES

    CEILINGWIRES

    Black

    White White +

    Black -

    strain relief bracket

    2B.2

    This luminaire is compatible with 12 Volts AC or DC circuits.

  • Artemide inc.250, Karin Lane, Hicksville (NY) 11801T. +1 631 694 9292 | [email protected] | www.artemide.net

    Artemide Ltd.11105, rue Renaude Lapointe, Montréal (QC) H1J 2T4

    T. +1 514 323 6537 | [email protected] | www.artemide.net2

    37 CUBELOW VOLTAGE Assembly instructions

    Y503-11528rev 0.1

    STEP 4 1. Push mounting springs upward.2. Insert the fixture in the ceiling.3. Fixture installed

    4.3