1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE...

26
1 SCALDABAGNO 13 L SE

Transcript of 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE...

Page 1: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

1

SCALDABAGNO 13 L SE

Page 2: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

2

SLB 13 L SE

• POTENZA:– POTENZA UTILE MINIMA 8,7 KW

– POTENZA UTILE MASSIMA 22,7 KW

• DATI IDRAULICI:– PRESSIONE MINIMA 0,3

BAR

– PRESSIONE MASSIMA 10 BAR

– PORTATA MINIMA DI ACCENSIONE CON POTENZIOMETRO DI REGOLAZIONE IMPOSTATO:

– ALLA MASSIMA TEMPERATURA 2,7 L/ MIN

– ALLA MINIMA TEMPERATURA 4,2 L/ MIN

• ACCENSIONE:– ACCENSIONE ELETTRONICA

– IONIZZAZIONE DI FIAMMA

• ESPULSIONE FUMI:– CAMERA STAGNA TIRAGGIO FORZATO

Page 3: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

3

SCALDABAGNISLB 13 L SE

Page 4: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

4

SCHEMA DEI CIRCUITI SLB 13 L SE

Page 5: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

5

SCAMBIATORE DI CALORE

• COMPITO– TRASFERIRE IL CALORE SVILUPPATO DALLA

COMBUSTIONE ALL’ACQUA CHE LO ATTRAVERSA

• DATI– PACCO LAMELLARE IN RAME ATTRAVERSATO

DA 5 TUBI ELITTICI CON ALL’INTERNO DEI TURBOLATORI.TUTTI QUESTI COMPONENTI SONO TRA LORO SALDATI CON BRASATURA FORTE E RICOPERTI DA UNA VERNICE DI PROTEZIONE CONTRO LA CORROSIONE.

Page 6: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

6

• COMPITO– RILEVA LA QUANTITA’ DI ACQUA CHE CIRCOLA

NELLO SCALDABAGNO, TRASMETTENDO L’INFORMAZIONE ALLA SCHEDA DI MODULAZIONE CHE ADEGUA DI CONSEGUENZA LA QUANTITA’ DI GAS AL BRUCIATORE PER MANTENERE COSTANTE LA TEMPERATURA DELL’ACQUA.

• CARATTERISTICHE– GRUPPO IN POLICARBONATO COSTITUITO DA UNA

GIRANTE INTERNA, CHE HA IL COMPITO DI TRASMETTERE UN SEGNALE DI FREQUENZA, PROPORZIONALE AL PRELIEVO D’ACQUA.

– MODELLO HONEYWELL

– TEMP. MAX. 80°C

– PRESS. MAX 17 bar

MISURATORE DI PORTATA

Page 7: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

7

MISURATORE DI PORTATA

Page 8: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

8

VALVOLA GAS• COMPITO

– REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE (MODUREG)

– APRE E CHIUDE IL GAS AL BRUCIATORE ATTRAVERSO GLI OPERATORI ON-OFF

– INTERROMPE L’AFFLUSSO DI GAS AL BRUCIATORE IN CASO DI SICUREZZA

• CARATTERISTICHE– MODELLO HONEYWELL VK 4105

– RESISTENZA OPERATORE EV1 2800 OHM

– RESISTENZA OPERATORE EV2 1300 OHM

– RESISTENZA MODUREG 117 ohm

Page 9: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

9

TARATURA VALVOLA GAS

• METANO– PRESSIONE MIN. AL BRUCIATORE 2,2 mbar– PRESSIONE MAX AL BRUCIATORE 13,1 mbar

• GAS BUTANO– PRESSIONE MIN. AL BRUCIATORE 3,4 mbar– PRESSIONE MAX AL BRUCIATORE 19 mbar

• GAS PROPANO– PRESSIONE MIN. AL BRUCIATORE 4,5 mbar– PRESSIONE MAX AL BRUCIATORE 24 mbar

Page 10: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

10

TARATURA LENTA ACCENSIONE

• COMPITO– MODIFICARE IL TEMPO DI APERTURA INIZIALE

DELLA VALVOLA PRINCIPALE

• CARATTERISTICHE– STEP POSIZIONATO SOTTO UN CAPPUCCIO DI

COLORE NERO– LA REGOLAZIONE SI ESEGUE AGENDO SULLA VITE

ROSSA IN MODO CONTINUO DA UN MINIMO A UN MASSIMO COMPIENDO 1/2 GIRO

Page 11: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

11

BRUCIATORE

• COMPITO– IL BRUCIATORE HA LA FUNZIONE DI PRODURRE

CALORE PER RISCALDARE L’ACQUA CHE CIRCOLA ALL’INTERNO DELLO SCAMBIATORE

• DATI– COMPOSTO DA 13 RAMPE IN ACCIAIO INOX

Page 12: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

12

COLLETTORE GAS

• DATI– 13 UGELLI DA 1,20 PER GAS METANO

– 13 UGELLI DA0,80 PER GPL

Page 13: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

13

ELETTRODI

• COMPITO– INCENDIARE LA MISCELA DI GAS E ARIA

COMBURENTE CHE FUORIESCE DALLE RAMPE DEL BRUCIATORE

– RILEVARE LA PRESENZA DI FIAMMA

Page 14: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

14

VENTILATORE

• COMPITO– ESPELLERE IN MODO FORZATO I PRODOTTI

DELLA COMBUSTIONE

• DATI– MODELLO EBM

– ALIMENTATO A 220 Vc.a.

– RESISTENZA DI CIRCA 40 OHM

Page 15: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

15

VENTURI

• COMPITO– CONTROLLA COSTANTEMENTE LA

DEPRESSIONE GENERATA DAL VENTILATORE

VENTURI

Page 16: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

16

PRESSOSTATO FUMI

• COMPITO– TRADUCE IN UN SEGNALE ELETTRICO LA

DEPRESSIONE CREATA DAL VENTURI– HONEYWELL– DA’ IL CONSENSO AD ACCENDERE IL BRUCIATORE

CON UNA DEPRESSIONE SUPERIORE A 6 mm.c.a.– SPEGNE LA FIAMMA SUL BRUCIATORE CON UNA

DEPRESSIONE INFERIORE A 4,5 m.c.a.

Page 17: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

17

CIRCUITO DI COMANDO

Page 18: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

18

SCHEDA DI COMANDO

• COMPITO– CONTROLLA LO SCALDABAGNO IN MODO DA

MANTENERE LA TEMPERATURA IL PIU’ COSTANTE POSSIBILE RISPETTO A QUELLA IMPOSTATA.

– RICEVE L’INFORMAZIONE DAL SENSORE DI PORTATA DANDO IL CONSENSO ALL’ACCENSIONE O ALLO SPEGNIMENTO DELLO SCALDABAGNO

• DATI– MODELLO HONEYWELL

Page 19: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

19

SENSORE DI TEMPERATURA

• COMPITO– ANALIZZA I VALORI DI TEMPERATURA E TRASMETTE I

DATI ALLA SCHEDA DI COMANDO

• DATI– SONDA FISSATA NELLA TUBAZIONE DI USCITA ACQUA

DALLO SCAMBIATORE DI CALORE– TABELLA CON I VALORI DI RESISTENZA A

TEMPERATURE DIVERSE

Page 20: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

20

SCHEDA DI ACCENSIONE

• COMPITO– CONTROLLA LE SEQUENZE DEL CICLO DI ESPULSIONE

FUMI E DEL CICLO DI ACCENSIONE DEL BRUCIATORE– CONTROLLA LA PRESENZA DI FIAMMA SUL

BRUCIATORE

• DATI– MODELLO HONEYWELL S 4565 CD

Page 21: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

21

TERMOSTATO DI SICUREZZA

• COMPITO– BLOCCA IL FUNZIONAMENTO DELLO SCALDABAGNO

PER ECCESSO DI TEMPERATURA

• DATI– KLICSON FISSATO ALLO SCAMBIATORE DI CALORE– TEMPERATURA DI INTERVENTO 85 °C

Page 22: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

22

SCHEMA DI FUNZIONAMENTO

Page 23: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

23

ALLACIAMENTI IDRAULICI

Page 24: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

24

SCARICO DEI PRODOTTI DELLA COMBUSTIONE

Page 25: 1 SCALDABAGNO 13 L SE. 2 SLB 13 L SE POTENZA: –POTENZA UTILE MINIMA 8,7 KW –POTENZA UTILE MASSIMA 22,7 KW DATI IDRAULICI: –PRESSIONE MINIMA 0,3 BAR –PRESSIONE.

25

RICERCA GUASTI