1
SCALDABAGNO 13 L SE
2
SLB 13 L SE
• POTENZA:– POTENZA UTILE MINIMA 8,7 KW
– POTENZA UTILE MASSIMA 22,7 KW
• DATI IDRAULICI:– PRESSIONE MINIMA 0,3
BAR
– PRESSIONE MASSIMA 10 BAR
– PORTATA MINIMA DI ACCENSIONE CON POTENZIOMETRO DI REGOLAZIONE IMPOSTATO:
– ALLA MASSIMA TEMPERATURA 2,7 L/ MIN
– ALLA MINIMA TEMPERATURA 4,2 L/ MIN
• ACCENSIONE:– ACCENSIONE ELETTRONICA
– IONIZZAZIONE DI FIAMMA
• ESPULSIONE FUMI:– CAMERA STAGNA TIRAGGIO FORZATO
3
SCALDABAGNISLB 13 L SE
4
SCHEMA DEI CIRCUITI SLB 13 L SE
5
SCAMBIATORE DI CALORE
• COMPITO– TRASFERIRE IL CALORE SVILUPPATO DALLA
COMBUSTIONE ALL’ACQUA CHE LO ATTRAVERSA
• DATI– PACCO LAMELLARE IN RAME ATTRAVERSATO
DA 5 TUBI ELITTICI CON ALL’INTERNO DEI TURBOLATORI.TUTTI QUESTI COMPONENTI SONO TRA LORO SALDATI CON BRASATURA FORTE E RICOPERTI DA UNA VERNICE DI PROTEZIONE CONTRO LA CORROSIONE.
6
• COMPITO– RILEVA LA QUANTITA’ DI ACQUA CHE CIRCOLA
NELLO SCALDABAGNO, TRASMETTENDO L’INFORMAZIONE ALLA SCHEDA DI MODULAZIONE CHE ADEGUA DI CONSEGUENZA LA QUANTITA’ DI GAS AL BRUCIATORE PER MANTENERE COSTANTE LA TEMPERATURA DELL’ACQUA.
• CARATTERISTICHE– GRUPPO IN POLICARBONATO COSTITUITO DA UNA
GIRANTE INTERNA, CHE HA IL COMPITO DI TRASMETTERE UN SEGNALE DI FREQUENZA, PROPORZIONALE AL PRELIEVO D’ACQUA.
– MODELLO HONEYWELL
– TEMP. MAX. 80°C
– PRESS. MAX 17 bar
MISURATORE DI PORTATA
7
MISURATORE DI PORTATA
8
VALVOLA GAS• COMPITO
– REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE (MODUREG)
– APRE E CHIUDE IL GAS AL BRUCIATORE ATTRAVERSO GLI OPERATORI ON-OFF
– INTERROMPE L’AFFLUSSO DI GAS AL BRUCIATORE IN CASO DI SICUREZZA
• CARATTERISTICHE– MODELLO HONEYWELL VK 4105
– RESISTENZA OPERATORE EV1 2800 OHM
– RESISTENZA OPERATORE EV2 1300 OHM
– RESISTENZA MODUREG 117 ohm
9
TARATURA VALVOLA GAS
• METANO– PRESSIONE MIN. AL BRUCIATORE 2,2 mbar– PRESSIONE MAX AL BRUCIATORE 13,1 mbar
• GAS BUTANO– PRESSIONE MIN. AL BRUCIATORE 3,4 mbar– PRESSIONE MAX AL BRUCIATORE 19 mbar
• GAS PROPANO– PRESSIONE MIN. AL BRUCIATORE 4,5 mbar– PRESSIONE MAX AL BRUCIATORE 24 mbar
10
TARATURA LENTA ACCENSIONE
• COMPITO– MODIFICARE IL TEMPO DI APERTURA INIZIALE
DELLA VALVOLA PRINCIPALE
• CARATTERISTICHE– STEP POSIZIONATO SOTTO UN CAPPUCCIO DI
COLORE NERO– LA REGOLAZIONE SI ESEGUE AGENDO SULLA VITE
ROSSA IN MODO CONTINUO DA UN MINIMO A UN MASSIMO COMPIENDO 1/2 GIRO
11
BRUCIATORE
• COMPITO– IL BRUCIATORE HA LA FUNZIONE DI PRODURRE
CALORE PER RISCALDARE L’ACQUA CHE CIRCOLA ALL’INTERNO DELLO SCAMBIATORE
• DATI– COMPOSTO DA 13 RAMPE IN ACCIAIO INOX
12
COLLETTORE GAS
• DATI– 13 UGELLI DA 1,20 PER GAS METANO
– 13 UGELLI DA0,80 PER GPL
13
ELETTRODI
• COMPITO– INCENDIARE LA MISCELA DI GAS E ARIA
COMBURENTE CHE FUORIESCE DALLE RAMPE DEL BRUCIATORE
– RILEVARE LA PRESENZA DI FIAMMA
14
VENTILATORE
• COMPITO– ESPELLERE IN MODO FORZATO I PRODOTTI
DELLA COMBUSTIONE
• DATI– MODELLO EBM
– ALIMENTATO A 220 Vc.a.
– RESISTENZA DI CIRCA 40 OHM
15
VENTURI
• COMPITO– CONTROLLA COSTANTEMENTE LA
DEPRESSIONE GENERATA DAL VENTILATORE
VENTURI
16
PRESSOSTATO FUMI
• COMPITO– TRADUCE IN UN SEGNALE ELETTRICO LA
DEPRESSIONE CREATA DAL VENTURI– HONEYWELL– DA’ IL CONSENSO AD ACCENDERE IL BRUCIATORE
CON UNA DEPRESSIONE SUPERIORE A 6 mm.c.a.– SPEGNE LA FIAMMA SUL BRUCIATORE CON UNA
DEPRESSIONE INFERIORE A 4,5 m.c.a.
17
CIRCUITO DI COMANDO
18
SCHEDA DI COMANDO
• COMPITO– CONTROLLA LO SCALDABAGNO IN MODO DA
MANTENERE LA TEMPERATURA IL PIU’ COSTANTE POSSIBILE RISPETTO A QUELLA IMPOSTATA.
– RICEVE L’INFORMAZIONE DAL SENSORE DI PORTATA DANDO IL CONSENSO ALL’ACCENSIONE O ALLO SPEGNIMENTO DELLO SCALDABAGNO
• DATI– MODELLO HONEYWELL
19
SENSORE DI TEMPERATURA
• COMPITO– ANALIZZA I VALORI DI TEMPERATURA E TRASMETTE I
DATI ALLA SCHEDA DI COMANDO
• DATI– SONDA FISSATA NELLA TUBAZIONE DI USCITA ACQUA
DALLO SCAMBIATORE DI CALORE– TABELLA CON I VALORI DI RESISTENZA A
TEMPERATURE DIVERSE
20
SCHEDA DI ACCENSIONE
• COMPITO– CONTROLLA LE SEQUENZE DEL CICLO DI ESPULSIONE
FUMI E DEL CICLO DI ACCENSIONE DEL BRUCIATORE– CONTROLLA LA PRESENZA DI FIAMMA SUL
BRUCIATORE
• DATI– MODELLO HONEYWELL S 4565 CD
21
TERMOSTATO DI SICUREZZA
• COMPITO– BLOCCA IL FUNZIONAMENTO DELLO SCALDABAGNO
PER ECCESSO DI TEMPERATURA
• DATI– KLICSON FISSATO ALLO SCAMBIATORE DI CALORE– TEMPERATURA DI INTERVENTO 85 °C
22
SCHEMA DI FUNZIONAMENTO
23
ALLACIAMENTI IDRAULICI
24
SCARICO DEI PRODOTTI DELLA COMBUSTIONE
25
RICERCA GUASTI
26
RICERCA GUASTI
Top Related