Federico Voglino – PM SE & ME Region Compomat ® G4.

Post on 20-Jan-2016

216 views 0 download

Transcript of Federico Voglino – PM SE & ME Region Compomat ® G4.

Federico Voglino – PM SE & ME Region

CompomatCompomat®® G4 G4

Federico Voglino – PM SE & ME Region

Compomat® G4Hardware

Compomat® G4Hardware

Compomaster™ NETSoftware

Compomaster™ NETSoftware

Compomation Datamanagement

Concept

Compomation Datamanagement

Concept

CompomatCompomat®® G4 G4

Federico Voglino – PM SE & ME Region

Quality in performance

CompomatCompomat®® G4 G4

Pressed for Quality and Pressed for Quality and PerformancesPerformances

Compomat G4Compomat G4 can satisfy the increasing demand in quality and standardization in blood component preparation.Many Blood Banks in Europe are ISO certified or certifying. The demand for quality, standardization and processing data management is rapidly increasing.

Compomat G4Compomat G4 can give the highest plasma and platelet yield and can improve the profitability of Blood component preparation.

Federico Voglino – PM SE & ME Region

Compomat G4 - HardwareCompomat G4 - Hardware

Control PanelControl Panel

Federico Voglino – PM SE & ME Region

Menu selection

Scroll buttons

Enter

DisplayDisplay

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

Operator buttonsOperator buttons

PausePause

StopStop On/OffOn/Off

Door CloseDoor Close Door OpenDoor Open

StartStart

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

Upper and Lower Press with Slide

and Multi Detection

Upper and Lower Press with Slide

and Multi Detection

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

Multi Detection Multi Detection

SlideSlide

Upper and Lower Pressprogrammable in steps

of 0.1mm

Upper and Lower Pressprogrammable in steps

of 0.1mm

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

Motor controlled flow limiter with

integrated detection

Motor controlled flow limiter with

integrated detection

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

Motor controlled flow limiterB detection in:• Normal mode• Fast mode

Motor controlled flow limiterB detection in:• Normal mode• Fast mode

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

6 Close – Seal heads

6 Close – Seal heads

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

• Tube positioning checking• High seal quality• User friendly maintenance

• Tube positioning checking• High seal quality• User friendly maintenance

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

Two scales for automatic registration of

weights

Two scales for automatic registration of

weights

Two scales for automatic

registration of weights

Top pressTop press

Compomat G4 - HardwareCompomat G4 - Hardware

Federico Voglino – PM SE & ME Region

CompoMat® G4CompoMat® G4

CompoMaster NETCompoMaster NET

Compomat G4 & Compomaster NETCompomat G4 & Compomaster NET

Federico Voglino – PM SE & ME Region

Upper and Lower Press independently programmable one

from each other

Upper and Lower Press independently programmable one

from each other

Compomat G4 - ProcedureCompomat G4 - Procedure

Federico Voglino – PM SE & ME Region

Compomat G4 - ProcedureCompomat G4 - Procedure

Federico Voglino – PM SE & ME Region

Buffy-Coat volume

programming by Upper Press

distance

Buffy-Coat volume

programming by Upper Press

distance

Motor controlled flow limiter

Motor controlled flow limiter

Compomat G4 - ProcedureCompomat G4 - Procedure

Federico Voglino – PM SE & ME Region

Hct programming by Multi Detector

Hct programming by Multi Detector

Compomat G4 - ProcedureCompomat G4 - Procedure

Federico Voglino – PM SE & ME Region

Slide to separate Buffy–Coat from erythrocytes

Slide to separate Buffy–Coat from erythrocytes

Compomat G4 - ProcedureCompomat G4 - Procedure

Federico Voglino – PM SE & ME Region

Buffy-CoatBuffy-Coat

PlasmaPlasma

ErythrocytesErythrocytes

Compomat G4 - ProcedureCompomat G4 - Procedure

Federico Voglino – PM SE & ME Region

Detection B/BFDetection B/BFOptimalPlasma

yield

OptimalPlasma

yield

OptimalErythrocytes

yield

OptimalErythrocytes

yield

Minimal lost of Buffy-Coat /Erythrocytes

Minimal lost of Buffy-Coat /Erythrocytes

Compomat G4 - ProcedureCompomat G4 - Procedure

Federico Voglino – PM SE & ME Region

Compomat G4 & Compomaster NETCompomat G4 & Compomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

• Allows personalization/modification on-line & step-by-step of the separation programs.

• Allows to save 50 different protocols.• Can manage up to 24 Compomat G4 network linked.• Store, print and exports the procedure data, even in

Excel format, customizable based on customer needs.• Allows procedure data transferring to the Blood Bank

computer system.• Bi-directional communication between Compomat and

computer system.

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

Federico Voglino – PM SE & ME Region

Compomaster NETCompomaster NET

• All kind of Bar Code reader recognition and check.• Time limit set for each process (Watch dog).• Compomaster NET – three levels for operation:

– G4 stand-alone.

– G4 computer linked: “Master” level.

– Programming level.• Compomaster NET safety features for the operator:

– Door close check: the door opens in case of obstruction.

– Tube positioning check, with acoustic alarm.

– G4 Stand by mode at the end of operator checks.

– SAG-M squeezing.

Federico Voglino – PM SE & ME Region

Compomat G4 - StrengthsCompomat G4 - Strengths

• Flexibility in programming (50 programs).• One balance for plasma and another one for Red Cells or

BC.• High standard and reproducible quality of blood

components.• Six clamp/sealing heads for complete automation of all

existing bags up to quintuple.• The finest regulation in separation parameters.

Federico Voglino – PM SE & ME Region

Compomat G4 - StrengthsCompomat G4 - Strengths

• Speed and quality in separation with ALL bags.• All bag systems can be used.• Integration and automation of In-line systems on

CompomatCompomat.• Maximal plasma yield collection and high platelet yield

collection optimizing the profitability of the blood component separation.

• Integrate offering package deals with blood bags.

Federico Voglino – PM SE & ME Region

Compomat G4 - StrengthsCompomat G4 - Strengths

Connected to CompomasterCompomaster

• Bidirectional communication between Compomaster-NETCompomaster-NET and the Blood Bank Host computer

• Automated procedure by Compomaster NETCompomaster NET and CompomationCompomation save labor cost

• Compomaster-NETCompomaster-NET under Windows XP

Federico Voglino – PM SE & ME Region

Compomat G4 - StrengthsCompomat G4 - Strengths

Patented:• A patent has been granted concerning the triple presstriple press

construction of CompomatCompomat (the essence of the product) in:

• USA• Japan• Germany• England• France• Sweden• Italy• the Netherlands

Federico Voglino – PM SE & ME Region

Ordering InformationOrdering Information

• 9028221 Compomat G4 • 902428/3 Air compressor• 9024181 Weighing scale• 9024391 Bar code scanner• 9024101 PC Compomat G4 w/ PhoneNET

card, GB language (w/Monitor)

Federico Voglino – PM SE & ME Region

Contact InformationContact Information

• For any further information you may need, please contact:

Federico Voglino

Product Manager SE & ME Region

federico.voglino@fresenius-kabi.com

+39-0535-45446

Fresenius Kabi Transfusion Technology