TRASFORMATORI DI CORRENTETOROIDALI

TOROIDAL CURRENTTRANSFORMERS

IDONEI ALL’INSTALLAZIONE IN CABINE ELETTRICHE CONNESSE ALLA RETE

DI MEDIA TENSIONE - 0,72kVIn conformita’ alla norma CEI 0-16 Ed. II - Luglio 2008

TEN50R - TEN60R - TEN70R

In conformita’ alla norma CEI 0-16 Ed. II - Luglio 2008TEN105R

In conformita’ alla norma CEI 0-16 Ed. II - Luglio 2008TEN105RD

Di misura e/o protezioneTEN.....

SUITAbLE FOR INSTALLATION IN ELECTRIC CAbINETS CONNECTED TO MEDIUM-VOLTAGE NETWORK - 0,72 KV Following to the standard CEI 0-16 Ed. II - July 2008 278 TEN50R - TEN60R - TEN70R

Following to the standard CEI 0-16 Ed. II - July 2008 279 TEN105R

Following to the standard CEI 0-16 Ed. II - July 2008 280 TEN105RD

Measuring and/or protection 281 TEN.....

TRASFORMATORI INMEDIA TENSIONE

MEDIUM VOLTAGETRANSFORMERS

DI CORRENTE NORME CEI-UNELDI CORRENTE A MATTONELLA

DI CORRENTE NORME DINDI TENSIONE NORME CEI-UNEL, FASE-FASE

DI TENSIONE NORME CEI-UNEL, FASE-TERRA DI TENSIONE NORME DIN, FASE-FASE

DI TENSIONE NORME DIN, FASE-TERRA DI TENSIONE CON PORTA FUSIBILE, FASE-TERRA

282 CURRENT TRANSFORMERS CEI-UNEL STANDARDS 284 bRICK TYPE CURRENT TRANSFORMERS 286 CURRENT TRANSFORMERS DIN STANDARDS 288 VOLTAGE CEI-UNEL STANDARDS, PHASE-PHASE 289 VOLTAGE CEI-UNEL STANDARDS, PHASE-GROUND 290 VOLTAGE DIN STANDARDS, PHASE-PHASE 291 VOLTAGE DIN STANDARDS, PHASE-GROUND 292 VOLTAGE FUSE-HOLDER, PHASE-GROUND

Il valore di torsione delle viti M4 è di 2,0 Nm.Il valore di torsione delle viti M3 è di 0,5 Nm.Il valore di torsione dei dadi M4 è di 1,0 Nm.

Torsion value of screws M4 is 2,0 Nm.Torsion value of screws M3 is 0,5 Nm.Torsion value of nuts M4 is 1,0 Nm.

COPPIA DI SERRAGGIO VITI MORSETTI SCREWS TORQUE VALUES

Page 3: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

278

TRASFORMATORI DI CORRENTE TOROIDALITOROIDAL CURRENT TRANSFORMERS

SUITABLE FOR INSTALLATION IN ELECTRIC CABINETS CONNECTED TO MEDIUM-VOLTAGE NETWORK - 0,72 kV

IDONEI ALL’INSTALLAZIONE IN CABINE ELETTRICHE CONNESSE ALLA RETE DI MEDIA TENSIONE - 0,72kV

IN CONFORMITA’ ALLA NORMACEI 0-16 Ed. II - Luglio 2008

FOLLOWING TO THE STANDARDCEI 0-16 Ed. II - July 2008

TEN50R - TEN60R - TEN70RTrasformatori di corrente per la protezione della massima corrente definito dalla norma CEI 0-16 “AUTOMATICAMENTE IDONEO”.Trasformatori dedicati all’alimentazione della protezione generale (PG) la cui funzione principale è quella di proteggere, il più possiblie in modo selettivo, la rete del Distributore in caso di guasto all’interno della rete del cliente e non le apparecchiature elettriche. I TEN.... devono poter alimentare con errori accettabili la protezione PG nel campo di variabilità atteso per la corrente di guasto primaria.TEN50R 300A Rapporto 300/5A - Classe 5P30 - Potenza 10VATEN50R 1 300A Rapporto 300/1A - Classe 5P30 - Potenza 5VATEN60R 300A Rapporto 300/5A - Classe 5P30 - Potenza 10VATEN60R 1 300A Rapporto 300/1A - Classe 5P30 - Potenza 5VATEN70R 300A Rapporto 300/5A - Classe 5P30 - Potenza 10VATEN70R 1 300A Rapporto 300/1A - Classe 5P30 - Potenza 5VA- Classe di isolamento II- Corrente termica nominale permanente 1,2 Ipn- Corrente termica nominale di corto circuito 12,5/16 kA per 1 secondo- Corrente dinamica nominale 31,5/40 kA pk- Tensione di prova 3kV a 50Hz per 1 minuto- Temperatura di funzionamento -20...+40°C- Tensione di riferimento per l’isolamento 0,72 kV- Frequenza di impiego 40...60Hz- Grado di protezione IP40- Classe di isolamento (EN 60085) A- Fissaggio direttamente su cavo- Costruzione secondo le norme CEI EN60044-1- Prova d’urto secondo le norme CEI EN60309:5 J- Tenuta alle correnti striscianti IEC 112:500V- Isolamento a secco in resina- Toroide inglobato in calotta termoplastica tipo ABS autoestinguente secondo le

norme UL94:V0- Uso interno- Coprimorsetto sigillabile sul secondario- Diametro interno adatto per cavo isolato a 24 kV

TEN50R - TEN60R - TEN70RCurrent transformers for the overcurrent protection defined by the CEI 0-16 “AUTOMATICALLY ELIGIBLE”.Transformers dedicated to power the General Protection (PG) and their principal function is to protect, in selective way, the Energy Distributor net in case of damage. TEN... transformers must power, with acceptable errors, the PG protection within the variable range accepted by the primary current.TEN50R 300A Ratio 300/5A - Class 5P30 - Power 10VATEN50R 1 300A Ratio 300/1A - Class 5P30 - Power 5VATEN60R 300A Ratio 300/5A - Class 5P30 - Power 10VATEN60R 1 300A Ratio 300/1A - Class 5P30 - Power 5VATEN70R 300A Ratio 300/5A - Class 5P30 - Power 10VATEN70R 1 300A Ratio 300/1A - Class 5P30 - Power 5VA Insulation class II- Permanent nominal thermic current 1,2 Ipn- Short circuit nominal thermic current 12,5/16 kA for 1 second- Nominal dynamic current 31,5/40 kA pk- Test voltage 3kV at 50Hz for 1 min- Working temperature -20...+40°C- Insulation voltage 0,72kV- Frequency 40…..60Hz- Protection degree IP 40- Insulation Class (EN 60085) A- Fixing system: directly on cable - Construction following the standards CEI EN60044-1- Shock test according to CEI EN60309:5 J- Resistance to tracking currents IEC 112:500V- Dry insulation resin- Toroid encased in thermoplastic ABS case, self-extinguishing according to

UL94:V0 standard- Internal use- Sealable terminal cover on the secondary- Interna diameter suitable for insulated cable 24 kV

TEN50R- Peso/Weight: 8 Kg

6,5

120R82

60°

104,

5

S1S2

ø180

ø70

6,5

ø275

R

60°145

63

ø16

0

6,5ø364

R

60°195

ø21

0

ø50

0

R

60°260

ø32

0

S1S2

80

S1S2

80

S1S2

6,5

92 R84

60°

83,5

S1S2

ø155ø

50

S1S2

ø230

125

60

ø10

5

28

S1S2

6,5

R84

60°

97

ø184

ø10

5

6,5

120R82

60°

104,

5

S1S2

ø180

ø70

6,5

ø275

R

60°145

63

ø16

0

6,5ø364

R

60°195

ø21

0

ø50

0

R

60°260

ø32

0

S1S2

80

S1S2

80

S1S2

6,5

92 R84

60°

83,5

S1S2

ø155

ø50

S1S2

ø230

125

60

ø10

5

28

S1S2

6,5

R84

60°

97

ø184

ø10

5

TEN70R- Peso/Weight: 10 Kg

TEN60R- Peso/Weight: 9 Kg

6,5

92

60°95,5

ø165

ø60

S1S2

Page 4: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

279

TEN105RTrasformatori di corrente per la protezione della massima corrente definito dalla norma CEI 0-16 “AUTOMATICAMENTE IDONEO”.I riduttori omopolari devono poter alimentare con errori accettabili la protezione PG nel campo di variabilità atteso per la corrente di guasto primaria.TEN105R 1 100A Rapporto 100/1A - Potenza 2VA- Classe di isolamento II- Corrente termica nominale permanente 800A- Corrente termica nominale di corto circuito 12,5/16 kA per 1 secondo- Corrente dinamica nominale 31,5/40 kA pk- Tensione di prova 3kV a 50Hz per 1 minuto- Temperatura di funzionamento -20...+40°C- Tensione di riferimento per l’isolamento 0,72 kV- Frequenza di impiego 40...60Hz- Grado di protezione IP40- Classe di isolamento (EN 60085) A- Fissaggio direttamente su cavo- Costruzione secondo le norme CEI EN60044-1- Prova d’urto secondo le norme CEI EN60309:5 J- Tenuta alle correnti striscianti IEC 112:500V- Isolamento a secco in resina- Toroide inglobato in calotta termoplastica tipo ABS autoestinguente secondo le

norme UL94:V0- Uso interno- Coprimorsetto sigillabile sul secondario- Diametro interno adatto per cavo isolato a 24 kV

TEN105RCurrent transformers for the overcurrent protection defined by the CEI 0-16 “AUTOMATICALLY ELIGIBLE”.Homopolar current transformers must power, with acceptable errors, the PG protection within the variable range accepted by the primary current.TEN105R 1 100A Ratio 100/1A - Power 2VA Insulation class II- Permanent nominal thermic current 800A- Short circuit nominal thermic current 12,5/16 kA for 1 second- Nominal dynamic current 31,5/40 kA pk- Test voltage 3kV at 50Hz for 1 min- Working temperature -20...+40°C- Insulation voltage 0,72kV- Frequency 40…..60Hz- Protection degree IP 40- Insulation Class (EN 60085) A- Fixing system: directly on cable - Construction following the standards CEI EN60044-1- Shock test according to CEI EN60309:5 J- Resistance to tracking currents IEC 112:500V- Dry insulation resin- Toroid encased in thermoplastic ABS case, self-extinguishing according to

UL94:V0 standard- Internal use- Sealable terminal cover on the secondary- Interna diameter suitable for insulated cable 24 kV

Toroide testato con i seguenti dispositivi di protezione generale certificati (TO omopolare con relè):Toroids tested with the following general protection certified devices (Homopolar TO with relais):- MICROELETTRICA SCIENTIFICA tipo/type N-DIN-016- THYTRONIC tipo/type NA10-NA30-NA60-NA016- COL GIOVANNI PAOLO, SEB DIVISIONE ELETTRONICA E SISTEMI tipo/type IFX4N-A1 / IFD4N-A1 / IFX3S- ALSTOM GRID tipo/type MX3AMD016A

Corrente / Current [I/In] Errore di rapporto / Ratio error [%] Errore d’angolo / Angle error [°] 0,01 +/- 5 +/- 2 0,05 +/- 1 +/- 2 1 +/- 1 +/- 2 20 +/- 5 +/- 2

Tabella errori di rapporto e di angolo ammessi / Table of ratio and angle errors admitted:

M6

Ø 105

60

60

Ø 230

32

53

59

23,5

30

50

TEN105R- Peso/Weight: 9 Kg

SUITABLE FOR INSTALLATION IN ELECTRIC CABINETS CONNECTED TO MEDIUM-VOLTAGE NETWORK - 0,72 kV

IDONEI ALL’INSTALLAZIONE IN CABINE ELETTRICHE CONNESSE ALLA RETE DI MEDIA TENSIONE - 0,72kV

IN CONFORMITA’ ALLA NORMACEI 0-16 Ed. II - Luglio 2008

FOLLOWING TO THE STANDARDCEI 0-16 Ed. II - July 2008

Page 5: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

280

TEN105RDTrasformatori di corrente per la protezione della massima corrente definito dalla norma CEI 0-16 “NON AUTOMATICAMENTE IDONEO”.I riduttori omopolari devono poter alimentare con errori accettabili la protezione PG nel campo di variabilità atteso per la corrente di guasto primaria.TEN105RD 1 100A Rapporto 100/1A - Potenza 0,5VA- Classe di isolamento II- Corrente termica nominale permanente 800A- Corrente termica nominale di corto circuito 12,5/16 kA per 1 secondo- Corrente dinamica nominale 31,5/40 kA pk- Tensione di prova 3kV a 50Hz per 1 minuto- Temperatura di funzionamento -20...+40°C- Tensione di riferimento per l’isolamento 0,72 kV- Frequenza di impiego 40...60Hz- Grado di protezione IP40- Classe di isolamento (EN 60085) A- Fissaggio direttamente su cavo- Costruzione secondo le norme CEI EN60044-1- Prova d’urto secondo le norme CEI EN60309:5 J- Tenuta alle correnti striscianti IEC 112:500V- Isolamento a secco in resina- Toroide inglobato in calotta termoplastica tipo ABS autoestinguente secondo le

norme UL94:V0- Uso interno- Coprimorsetto sigillabile sul secondario- Diametro interno adatto per cavo isolato a 24 kV- Conduttori di collegamento al relè: lunghezza (andata e ritorno) max 10m sezione non inferiore a 4 mm2

TEN105RDCurrent transformers for the overcurrent protection defined by the CEI 0-16 “NOT AUTOMATICALLY ELIGIBLE”.Homopolar current transformers must power, with acceptable errors, the PG protection within the variable range accepted by the primary current.TEN105RD 1 100A Ratio 100/1A - Power 0,5VA Insulation class II- Permanent nominal thermic current 800A- Short circuit nominal thermic current 12,5/16 kA for 1 second- Nominal dynamic current 31,5/40 kA pk- Test voltage 3kV at 50Hz for 1 min- Working temperature -20...+40°C- Insulation voltage 0,72kV- Frequency 40…..60Hz- Protection degree IP 40- Insulation Class (EN 60085) A- Fixing system: directly on cable - Construction following the standards CEI EN60044-1- Shock test according to CEI EN60309:5 J- Resistance to tracking currents IEC 112:500V- Dry insulation resin- Toroid encased in thermoplastic ABS case, self-extinguishing according to

UL94:V0 standard- Internal use- Sealable terminal cover on the secondary- Interna diameter suitable for insulated cable 24 kV- Connection cable to relay: length (round trip) Max 10m section not less than 4 mm2

Toroide testato con i seguenti dispositivi di protezione generale certificati (TO omopolare con relè):Toroids tested with the following general protection certified devices (Homopolar TO with relais):- MICROELETTRICA SCIENTIFICA tipo/type N-DIN-016- THYTRONIC tipo/type NA10-NA30-NA60-NA016- COL GIOVANNI PAOLO, SEB DIVISIONE ELETTRONICA E SISTEMI tipo/type IFX4N-A1 / IFD4N-A1 / IFX3S- ALSTOM GRID tipo/type MX3AMD016A

Corrente / Current [I/In] Errore di rapporto / Ratio error [%] Errore d’angolo / Angle error [°] 0,01 +/- 5 +/- 2 0,05 +/- 1 +/- 2 1 +/- 1 +/- 2 20 +/- 5 +/- 2

Tabella errori di rapporto e di angolo ammessi / Table of ratio and angle errors admitted:

M4

28

28

Ø 184

16

Ø 6,5

120°

36

97

2150

18,5

Ø 1

05

TEN105RD- Peso/Weight: 2 Kg

SUITABLE FOR INSTALLATION IN ELECTRIC CABINETS CONNECTED TO MEDIUM-VOLTAGE NETWORK - 0,72 kV

IDONEI ALL’INSTALLAZIONE IN CABINE ELETTRICHE CONNESSE ALLA RETE DI MEDIA TENSIONE - 0,72kV

IN CONFORMITA’ ALLA NORMACEI 0-16 Ed. II - Luglio 2008

FOLLOWING TO THE STANDARDCEI 0-16 Ed. II - July 2008

Page 6: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

281

TEN...- Corrente nominale primaria da 40 a 6000A da comunicare in fase d’ordine- Corrente secondaria 5A o 1A da comunicare in fase d’ordine- Numero avvolgimenti secondari 1 o 2 a richiesta- Numero avvolgimenti primari 1 o 2 a richiesta- Frequenza 40 - 60 Hz- Tensione di prova 3 kV per 1 minuto- Isolamento classe E- Sovracorrente permanente 1,2 In- Corrente termica di corto circuito (Iter) fino a 40kA per 1 sec.- Corrente dinamica di corto circuito (Idin) 2,5 Iter per 1 sec.- Protezione minima IP40- Fattore di sicurezza (Fs) < 10 per i trasformatori di misura- Temperatura di funzionamento -20°C ÷ +40°C; di stoccaggio -40°C ÷ +80°C- Costruzione secondo le norme CEI EN60044-1- Installazione x interno- Prestazioni a richiesta. In fase d’ordine o di offerta comunicare il rapporto

di trasformazione (corrente primaria e secondaria), la prestazione (VA) e la classe di precisione ( es: cl.0,5, 5P10, ecc.)

TEN...- Nominal primary current from 40 to 6000A to specify when ordering- Secondary current 5A or 1A to specify when ordering- Secondary coils 1 or 2 on request- Primary coils 1 or 2 on request- Frequency 40 - 60 Hz- Test voltage 3 kV for 1 min- Insulation class E- Permanent over current 1,2 In- Short circuit thermic current (Iter) up to 40kA for 1 second- Short circuit dynamic current (Idin) 2,5 Iter for 1 second- Minimum protection degree IP40- Safety factor (Fs) < 10 for measurement transformers- Temperature working -20°C ÷ +40°C; storage -40°C ÷ +80°C- Construction following the standards CEI EN60044-1- Indoor installation- During the offer it is necessary to specify all the technical details: primary

and secondary, power (VA), class (example: cl.0,5, 5P10, ecc.)

6,5

120R82

60°

104,

5

S1S2

ø180

ø70

6,5

ø275

R

60°145

63

ø16

0

6,5ø364

R

60°195

ø21

0

ø50

0

R

60°260

ø32

0

S1S2

80

S1S2

80

S1S2

6,5

92 R84

60°

83,5

S1S2

ø155

ø50

S1S2

ø230

125

60

ø10

5

28

S1S2

6,5

R84

60°

97

ø184

ø10

5

TOROIDI DI MISURA e/o PROTEZIONE TOROIDS FOR MEASURING and/or PROTECTION

TEN50R- Peso/Weight: 8 Kg

TEN105R- Peso/Weight: 9 Kg

TEN60R- Peso/Weight: 9 Kg

6,5

120R82

60°

104,

5

S1S2

ø180

ø70

6,5

ø275

R

60°145

63

ø16

0

6,5ø364

R

60°195

ø21

0

ø50

0

R

60°260

ø32

0

S1S2

80

S1S2

80

S1S2

6,5

92 R84

60°

83,5

S1S2

ø155

ø50

S1S2

ø230

125

60

ø10

5

28

S1S2

6,5

R84

60°

97

ø184

ø10

5

6,5

120R82

60°

104,

5

S1S2

ø180

ø70

6,5

ø275

R

60°145

63

ø16

0

6,5ø364

R

60°195

ø21

0

ø50

0

R

60°260

ø32

0

S1S2

80

S1S2

80

S1S2

6,5

92 R84

60°

83,5

S1S2

ø155

ø50

S1S2

ø230

125

60

ø10

5

28

S1S2

6,5

R84

60°

97

ø184

ø10

5

6,5

120R82

60°

104,

5

S1S2

ø180

ø70

6,5

ø275

R

60°145

63

ø16

0

6,5ø364

R

60°195

ø21

0

ø50

0

R

60°260

ø32

0

S1S2

80

S1S2

80

S1S2

6,5

92 R84

60°

83,5

S1S2

ø155

ø50

S1S2

ø230

125

60

ø10

5

28

S1S2

6,5

R84

60°

97

ø184

ø10

5

TEN160R

TEN210R

Coprimorsetto sigillabile per: Sealable terminals cover for: TEN60R, TEN70R, TEN105R, TEN160R, TEN210R, TEN320R

Coprimorsetto sigillabile per: Sealable terminals cover for: TEN50R

SUITABLE FOR INSTALLATION IN ELECTRIC CABINETS CONNECTED TO MEDIUM-VOLTAGE NETWORK - 0,72 kV

IDONEI ALL’INSTALLAZIONE IN CABINE ELETTRICHE CONNESSE ALLA RETE DI MEDIA TENSIONE - 0,72kV

6,5

120R82

60°

104,

5

S1S2

ø180

ø70

6,5

ø275

R

60°145

63

ø16

0

6,5ø364

R

60°195

ø21

0

ø50

0

R

60°260

ø32

0

S1S2

80

S1S2

80

S1S2

6,5

92 R84

60°

83,5

S1S2

ø155

ø50

S1S2

ø230

125

60

ø10

5

28

S1S2

6,5

R84

60°

97

ø184

ø10

5

TEN70R- Peso/Weight: 10 Kg

6,5

92

60°95,5

ø165

ø60

S1S2

6,5

120R82

60°

104,

5

S1S2

ø180

ø70

6,5

ø275

R

60°145

63

ø16

0

6,5ø364

R

60°195

ø21

0

ø50

0

R

60°260

ø32

0

S1S2

80

S1S2

80

S1S2

6,5

92 R84

60°

83,5

S1S2

ø155

ø50

S1S2

ø230

125

60

ø10

5

28

S1S2

6,5

R84

60°

97

ø184

ø10

5

TEN320R

Page 7: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

282

- Dimensioni secondo norme CEI-UNEL 21009 - Costruiti e provati secondo IEC 60044-1- Prestazioni standard misura = cl 0,5 / 20VA; protezione = cl 5P10 / 10VA- Livello di isolamento nominale fino a 36 kV- Frequenza 50 o 60 Hz- Corrente nominale primaria (Ipn):

- Singola corrente primaria: da 5 a 2500 A - Doppia corrente primaria: fino a 2x300 A con cambio rapp. al primario fino a 2x1250 A con cambio rapp. al secondario

- Corrente nominale secondaria (Isn) 5 A- Corrente di breve durata (Ith) fino a 40 kA x 1s- Corrente dinamica nominale (Idyn) 2.5 x Ith- Numero di secondari 1 o 2- Fattore di sicurezza ≤ 5 o ≤ 10- Installazione per internoA RICHIESTA- Terzo secondario - Corrente nominale secondaria 1A- Coprimorsettiera sigillabile - Presa capacitiva- In fase di offerta è necessario specificare tutti i dati tecniciESEMPI D’ORDINERAA111 300- 300A 5A trasformatore con doppio primario 300ARAA121 300A 5-5A trasformatore 300A con doppio secondarioRAA141 2k5 5-5-5A trasformatore 2500A con triplo secondario

- Dimensions according to CEI-UNEL 21009 std. - Manufactured and tested acc. to IEC 60044-1- Standard burden: measure = cl 0,5 / 20VA; protection = cl 5P10 / 10VA- Rated Insulation level up to 36 kV- Frequency 50 or 60 Hz- Rated primary current (Ipn):

- Single primary current from 5 to 2500 A- Double primary current Up to 2x300 A change on primary winding Up to 2x1250 A change on secondary winding

- Rated secondary current (Isn) 5 A- Short-time current (Ith) up to 40 kA x 1s- Rated dynamic current (Idyn) 2.5 x Ith- Number of secondary 1 or 2- Safety factor ≤ 5 or ≤ 10- Indoor installationoN REQuEST- Third secondary - Rated secondary current 1A- Sealable terminal cover - Capacitive tap- During the offer it is necessary to specify all technical detailsoRDER ExamPlERAA111 300- 300A 5A current transformer with double primary 300ARAA121 300A 5-5A current transformer 300A with double secondaryRAA141 2k5 5-5-5A current transformer 2500A with triple secondary

Sec 1 Sec 2

A B

P2P1

C1

C2

C2P1

C1 P2

1s1 1s2 2s1 2s2

1s1 1s3 2s1 2s3

RAPPORTO MINORE / loW RaTio

RAPPORTO MAGGIORE / HigH RaTio

P1

P2

Ø14

50= = 90

120M12

40

==

10-1560

3210

Ø14

15-20

40

80

40

20

ø18

da 1500A a 2500 Afrom 1500A to 2500A

≤ 2x300 A ≤ 2x1250 A

da 800A a 1200 Afrom 800A to 1200A

Sec 1 Sec 2

SECONDO / accoRDiNg To: IEC/CEI EN 60071-1

[mm] 12 kV 24 kV 36 kV A 120 220 320 B 120 220 320

TRASFORMATORI DI CORRENTE NORME CEI-UNEL CURRENT TRANSFORMERS CEI-UNEL STANDARDS

TERMINALI PRIMARI PRIMARY TERMINALS

DOPPIA CORRENTE PRIMARIA DOUbLE PRIMARY CURRENT

DISTANZE DI MONTAGGIO MINIME MINIMUM ASSEMbLY DISTANCES

Page 8: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

283

12 kV

RAA111 RAA121 RAA131 RAA141

Dimensioni / dimensions [mm] A B C D E F RAA111 250 180 200 145 105 28 RAA121 250 180 200 175 105 28 RAA131 300 190 220 190 130 50 RAA141 300 190 240 190 130 50

P2P1

A

E

220 Ø14

20

6

C2C1

M6

C

160

300

B

265

Max

F

D

5

240

155

155

Ø11M12

1s1 1s2 2s1 2s2

Sec 1 Sec 2

Ip Max 600AMax. N° sec. 1

Kg. ~ 14

Ip Max 600AMax. N° sec. 2

Kg. ~ 16

Ip Max 1200AMax. N° sec. 2

Kg. ~ 23

Ip Max 2500AMax. N° sec. 3

Kg. ~ 25

Dimensioni / dimensions [mm] A B C D E F RAB111 300 200 200 150 130 17.5 RAB121 300 200 200 175 130 17.5 RAB131 300 200 220 200 130 17.5 RAB161 300 200 240 200 130 17.5

RAB111 RAB121 RAB131 RAB161

Ip Max 600AMax. N° sec. 1

Kg. ~ 16

RAC121

Dimensioni / dimensions [mm] A B C D E F 330 250 240 230 165 17.5

Ip Max 2500AMax. N° sec. 3

Kg. ~ 30

Ip Max 600AMax. N° sec. 2

Kg. ~ 18

Ip Max 1000AMax. N° sec. 2

Kg. ~ 25

Ip Max 2500AMax. N° sec. 3

Kg. ~ 28A

E

6

20 Ø14

P1 C1

C2 P2

220

M6

C

160

340

B

325

Max

F

D

5

300

175

225

Ø11M12

P2

P1

A

E

220Ø14

20

6

C2

C1

D

M6

C

410

B

395

Max

F

5

370

225

300

Ø11 M12

160

A

E

6

20 Ø14

P1 C1

C2 P2

220

M6

C

160

340

B

325

Max

F

D

5

300

175

225

Ø11M12

A

E

6

20 Ø14

P1 C1

C2 P2

220

M6

C

160

340

B

325

Max

F

D

5

300

175

225

Ø11M12

P2

P1

A

E

220Ø14

20

6

C2

C1

D

M6

C

410

B

395

Max

F

5

370

225

300

Ø11 M12

160

P2

P1

A

E

220Ø14

20

6

C2

C1

D

M6

C

410

B

395

Max

F

5

370

225

300

Ø11 M12

160

24 kV

36 kV

P2

P1

A

E

220Ø14

20

6

C2

C1

D

M6

C

410

B

395

Max

F

5

370

225

300

Ø11 M12

160

Page 9: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

284

P1 C2

C1 P2

P2

C1

C2

P1

Sec 1 Sec 2

1s1 1s2 2s1 2s2

1s1 1s3 2s1 2s3

Sec 1 Sec 2

- Modello compatto adatto per quadri tipo METAL-CLAD- Costruiti e provati secondo IEC 60044-1- Prestazioni standard: misura = cl 0,5 / 20VA; protezione = cl 5P10 / 10VA- Livello di isolamento nominale fino a 24 kV- Frequenza 50 o 60 Hz- Corrente nominale primaria (Ipn)

- Singola corrente primaria da 5 a 1250 A - Doppia corrente primaria: fino a 2 x 300 A con cambio rapp. al primario

fino a 2 x 600 A con cambio rapp. al secondario- Corrente nominale secondaria (Isn) 5 A- Corrente di breve durata (Ith) fino a 40 kA x 1s- Corrente dinamica nominale (Idyn) 2.5 x Ith- Numero di secondari 1 o 2- Fattore di sicurezza ≤ 5 o ≤ 10- Installazione per internoA RICHIESTA- Terzo secondario - Corrente nominale secondaria 1A- Coprimorsettiera sigillabile - Presa capacitiva- In fase di offerta è necessario specificare tutti i dati tecniciESEMPI D’ORDINERABM11 1k25 5A trasformatore di corrente 1250A con singolo secondarioRABM22-A 1k25 5-5A trasformatore di corrente 1250A con doppio secondarioRABM11-B 1k25 5-5-5A trasformatore di corrente 1250A con triplo secondario

P1

P2

32= = 65

120M12

40 =

=

da 5A a 1250Afrom 5A to 1250A

≤ 2x600 A≤ 2x300 A

TRASFORMATORI DI CORRENTE A MATTONELLAbRICK TYPE CURRENT TRANSFORMERS

- Compact type suitable for METAL - CLAD switchboards- Manufactured and tested acc. to IEC 60044-1- Standard burden: measure = cl 0,5 / 20VA; protection = cl 5P10 / 10VA- Rated Insulation level up to 24 kV- Frequency 50 or 60 Hz- Rated primary current (Ipn)

- Single primary current from 5 to 1250 A- Double primary current: Up to 2 x 300 A change on prim. winding

Up to 2 x 600 A change on sec. winding- Rated secondary current (Isn) 5 A- Short-time current (Ith) up to 40 kA x 1s- Rated dynamic current (Idyn) 2.5 x Ith- Number of secondary 1 or 2- Safety factor ≤ 5 or ≤ 10- Indoor installationoN REQuEST- Third secondary - Rated secondary current 1A- Sealable terminal cover - Capacitive tap- During the offer it is necessary to specify all technical detailsoRDER ExamPlERABM11 1k25 5A current transformer 1250A with single secondaryRABM22-A 1k25 5-5A current transformer 1250A with double secondaryRABM11-B 1k25 5-5-5A current transformer 1250A with triple secondary

TERMINALI PRIMARI PRIMARY TERMINALS

DOPPIA CORRENTE PRIMARIA DOUbLE PRIMARY CURRENT

DISTANZE DI MONTAGGIO MINIME MINIMUM ASSEMbLY DISTANCES

BA

SECONDO / accoRDiNg To: IEC/CEI EN 60071-1

[mm] 24 kV A 220 B 220

RAPPORTO MINORE / loW RaTio

RAPPORTO MAGGIORE / HigH RaTio

Page 10: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

285

CON SUPPORTI METALLICI 24 kVWITH METALLIC SUPPORTS 24 kV

P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

1s1 1s2 2s1 2s2

Sec 1 Sec 2

RABM22Ip Max 1250AMax. N° sec. 3

Kg. ~ 25

RABM11Ip Max 1250AMax. N° sec. 3

Kg. ~ 18

Dimensioni / dimensions [mm] A B RABM11 148 120 RABM22 198 160

SENZA SUPPORTI METALLICI - TERMINALI SECONDARI IN ESECUZIONE “A” 24 kVWITHOUT METALLIC SUPPORTS - SECONDARY TERMINALS EXECUTION “A” 24 kV

RABM22-AIp Max 1250AMax. N° sec. 3

Kg. ~ 25

RABM11-AIp Max 1250AMax. N° sec. 3

Kg. ~ 18P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

Dimensioni / dimensions [mm] A RABM11-A 148 RABM22-A 198

P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

P2P1

320

C2

C1

A

254

235

B

120 3232

M6

P2P1

C2

C1

150

235

120

120 3232

M6

5

254

300

Ø11M12

160 127

260

Max

260

Max

10

52

AA

M12

247

88

272

Max

P2P1

C2

C1

198

120 3232

254

127

M12

150

120

52

M8

M8

Dimensioni / dimensions [mm] A RABM11-B 148 RABM22-B 198

SENZA SUPPORTI METALLICI - TERMINALI SECONDARI IN ESECUZIONE “B” 24 kVWITHOUT METALLIC SUPPORTS - SECONDARY TERMINALS EXECUTION “b” 24 kV

RABM22-BIp Max 1250AMax. N° sec. 3

Kg. ~ 25

RABM11-BIp Max 1250AMax. N° sec. 3

Kg. ~ 18

Page 11: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

286

Ka P1

Lb P2

La C2

KbC1

P1

P2

C2

C1

Ø14

105

60

40

2

34

32

139

75

250

PG16

150 177.5

350

32

55

148

5

220

125

105

270

M12 120 3232

250

300

148

5

220

105

M6

120 3232

125

150

Ø14

270

M12

245

Max

245

Max

15 15

Ka P1

Lb P2

La C2

KbC1

P1

P2

C2

C1

Ø14

105

60

40

2

34

32

139

75

250

PG16

150 177.5

350

32

55

148

5

220

125

105

270

M12 120 3232

250

300

148

5

220

105

M6

120 3232

125

150

Ø14

270

M12

245

Max

245

Max

15 15

Ka P1

Lb P2

La C2

KbC1

P1

P2

C2

C1

Ø14

105

60

40

2

34

32

139

75

250

PG16

150 177.5

350

32

55

148

5

220

125

105

270

M12 120 3232

250

300

148

5

220

105

M6

120 3232

125

150

Ø14

270

M12

245

Max

245

Max

15 15

Ka P1

Lb P2

La C2

Kb C1

Ka P1

Lb P2

La C2

Kb C1P2Lb

C1Kb

C2LaP1Ka

Kb C1

La C2

P2Lb

Ka P1

12 kV 24kVSec 2Sec 1

1s21s1 2s1 2s2

1s1 1s3 2s1 2s3

M5

M5

Sec 1 Sec 2

1s21s1 2s1 2s2

1s1 1s3 2s1 2s3

M5

M5

800-2500 A5-600 A

- Dimensioni: norme DIN 42 600 TEIL 8. Costruiti e provati secondo IEC 60044-1- Prestazioni standard: misura = cl 0,5 / 20VA; protezione = cl 5P10 / 10VA- Corrente primaria (Ipn): Singola da 5 a 2500 A

Doppia fino a 2x300A con cambio rapp. al prim. fino a 2x1250A con cambio rapp. al sec.- Corrente nominale secondaria (Isn) / Frequenza 5 A / 50 o 60 Hz- Corrente di breve durata (Ith) fino a 40 kA x 1s- Corrente dinamica nominale (Idyn) 2.5 x Ith- Numero di secondari / attore di sicurezza 1 o 2 / ≤ 5 o ≤ 10- Installazione per interno, morsetti secondari secondo DINA RICHIESTA- Terzo secondario, Corrente nominale secondaria 1A, Presa capacitiva,

Esecuzione con alette, Morsetti secondari ns. standard- In fase di offerta è necessario specificare tutti i dati tecniciESEMPI D’ORDINERAAD11 2k5 5A trasformatore di corrente 2500A con singolo secondarioRAAD11-N 2k5 5-5A trasformatore di corrente 2500A con doppio secondarioRABD11-AN 2k5 5-5-5A trasformatore di corrente 2500A con triplo secondario

BA

Ka P1

P2Lb

32= =65

120M12

40

==

Ka

P1 Lb

P2

70

120

7032= =

40

=

=

M12

SECONDO / accoRDiNg To: IEC/CEI EN 60071-1

[mm] 12 kV 24 kV A 120 220 B 120 220

TRASFORMATORI DI CORRENTE NORME DINCURRENT TRANSFORMERS DIN STANDARDS

- Dimensions: DIN 42 600 TEIL 8 std. Manufactured and tested: IEC 60044-1- Standard burden: measure = cl 0,5 / 20VA; protection = cl 5P10 / 10VA- Rated primary current (Ipn): Single from 5 to 2500 A

Double Up to 2 x 300 A change on prim. winding Up to 2 x 1250 A change on sec. winding- Rated secondary current (Isn) / Frequency 5 A / 50 or 60 Hz- Short-time current (Ith) up to 40 kA x 1s- Rated dynamic current (Idyn) 2.5 x Ith- Number of secondary / Security factor 1 or 2 / ≤ 5 or ≤ 10- Indoor installation, secondary terminal board accordint to DINoN REQuEST- Third secondary, Rated secondary current 1A, Capacitive tap, Execution with

wings, Standard sec. terminal board- During the offer it is necessary to specify all technical detailsoRDER ExamPlERAAD11 2k5 5A current transformer 2500A with single secondaryRAAD11-N 2k5 5-5A current transformer 2500A with double secondaryRABD11-AN 2k5 5-5-5A current transformer 2500A with triple secondary

TERMINALI PRIMARI PRIMARY TERMINALS

DOPPIA CORRENTE PRIMARIA DOUbLE PRIMARY CURRENT

DISTANZE DI MONTAGGIO MINIME MINIMUM ASSEMbLY DISTANCES

RAPPORTO MINOREloW RaTio

RAPPORTO MAGGIOREHigH RaTio

da 5A a 1500Afrom 5A to 1500A

da 5A a 2500Afrom 5A to 2500A

MORSETTI SECONDARI NORME DIN 12 kVSECONDARY TERMINALS DIN STANDARDS 12 kV

RAAD11Esecuzione standard Standard execution

Ip Max 2500AMax. N° sec. 3Kg. ~ 18

RAAD11-AEsecuzione con alette Wings execution

Ip Max 2500AMax. N° sec. 3Kg. ~ 18

Page 12: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

287

C1Kb

C2La

P2Lb

P1Ka

280

5

75

139

32

34

32

55

2

40

60

105

270

PG16

365

155 187.5

105

150

120 3232

178

Ø14M12

280

305

Max

15

C1

C2

P2

P1

310

270

528

0

105

M6

150

120 3232 Ø14M12

280

178155

305

Max

15

C1Kb

C2La

P2Lb

P1Ka

280

5

75

139

32

34

32

55

2

40

60

105

270

PG16

365

155 187.5

105

150

120 3232

178

Ø14M12

280

305

Max

15

C1

C2

P2

P1

310

270

528

0

105

M6

150

120 3232 Ø14M12

280

178155

305

Max

15

Ka P1

Lb P2

La C2

KbC1

P1

P2

C2

C1

Ø14

105

60

40

2

34

32

13975

250

PG16

150 177.5

350

32

55

148

5

220

125

105

270

M12 120 3232

250

300

148

5

220

105

M6

120 3232

125

150

Ø14

270

M12

245

Max

245

Max

15 15

Ka P1

Lb P2

La C2

KbC1

P1

P2

C2

C1

Ø14

105

60

40

2

34

32

139

75

250

PG16

150 177.5

350

32

55

148

5

220

125

105

270

M12 120 3232

250

300

148

5

220

105

M6

120 3232

125

150

Ø14

270

M12

245

Max

245

Max

15 15

RAAD11-NEsecuzione standardStandard execution

Ip Max 2500AMax. N° sec. 3Kg. ~ 18

RAAD11-ANEsecuzione con alette Wings execution

Ip Max 2500AMax. N° sec. 3Kg. ~ 18

MORSETTI SECONDARI NOSTRO STANDARD 12 kVSTANDARD SECONDARY TERMINAL bOARD 12 kV

MORSETTI SECONDARI NOSTRO STANDARD 24 kVSTANDARD SECONDARY TERMINAL bOARD 24 kV

MORSETTI SECONDARI NORME DIN 24 kVSECONDARY TERMINALS DIN STANDARDS 24 kV

RABD11Esecuzione standardStandard execution

Ip Max 2500AMax. N° sec. 3Kg. ~ 18

RABD11-AEsecuzione con alette Wings execution

Ip Max 2500AMax. N° sec. 3Kg. ~ 25

C1Kb

C2La

P2Lb

P1Ka

280

5

75

139

32

34

32

55

2

40

60

105

270

PG16

365

155 187.5

105

150

120 3232

178

Ø14M12

280

305

Max

15

C1

C2

P2

P1

310

270

528

0

105

M6

150

120 3232 Ø14M12

280

178155

305

Max

15

C1Kb

C2La

P2Lb

P1Ka

280

5

75

139

32

34

32

55

2

40

60

105

270

PG16

365

155 187.5

105

150

120 3232

178

Ø14M12

280

305

Max

15

C1

C2

P2

P1

310

270

528

0

105

M6

150

120 3232 Ø14M12

280

178155

305

Max

15

C1Kb

C2La

P2Lb

P1Ka

280

5

75

139

32

34

32

55

2

40

60

105

270

PG16

365

155 187.5

105

150

120 3232

178

Ø14M12

280

305

Max

15

C1

C2

P2

P1

310

270

528

0

105

M6

150

120 3232 Ø14M12

280

17815530

5 M

ax

15

RABD11-NEsecuzione standardStandard execution

Ip Max 2500AMax. N° sec. 3Kg. ~ 25

RABD11-ANEsecuzione con alette Wings execution

Ip Max 2500AMax. N° sec. 3Kg. ~ 25

Page 13: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

288

BA

D

5

M

L

G

F

E

M6

B

A

C

D

A B

F

B

A

E

5

GC

L

M

M6

IH

260

N N

Ø11M10

Ø11M10

a1 b1 a2 b2

Sec 1 Sec 2

BA

D

5

M

L

G

F

E

M6

B

A

C

D

A B

F

B

A

E

5

GC

L

M

M6

IH

260

N N

Ø11M10

Ø11M10

a1 b1 a2 b2

Sec 1 Sec 2

RAPPORTO MINORE / loW RaTio RAPPORTO MAGGIORE / HigH RaTio

BA M10BA M10

Sec 1 Sec 2

2a1 2b1b1a1

Sec 1 Sec 2

2a2 2b1b1a2

- Dimensioni: norme CEI-UNEL 21008. Costruiti e provati secondo IEC 60044-2- Prestazioni standard: misura = cl 0,5 / 50VA- Frequenza 50 o 60 Hz- Fattore di tensione 1,2 per tempo illimitato- Numero di secondari 1- Tensione nominale secondaria 100 V- Installazione per internoA RICHIESTA- Secondario aggiuntivo - Doppio rapporto primario- Coprimorsettiera sigillabile - Tensione nominale secondaria 110 V- In fase di offerta è necessario specificare tutti i dati tecniciESEMPI D’ORDINERVCA11 10/10 (10000/100V)RVCB11 20/10 (20000/100V)

- Dimensions: CEI-UNEL 21008 std. Manufactured and tested: IEC 60044-2- Standard burden: measure = cl 0,5 / 50VA- Frequency 50 or 60 Hz- Rated voltage factor 1,2 continuous- Number of secondary 1- Rated secondary voltage 100 V- Indoor installationoN REQuEST- Second secondary - Double primary ratio- Sealable terminal cover - Rated secondary voltage 110 V- During the offer it is necessary to specify all technical detailsoRDER ExamPlERVCA11 10/10 (10000/100V)RVCB11 20/10 (20000/100V)

12 kV - 24 kV - 36 kV

RVCA11Upn (kV) ≤ 12Max. N° sec. 2

Kg. ~ 20

RVCB11Upn (kV) ≤ 24Max. N° sec. 2

Kg. ~ 30

RVCC11

Upn (kV) ≤ 36Max. N° sec. 2

Kg. ~ 50

Dimensioni / dimensions [mm] A B C D E F G H I L M N RVCA11 305 180 240 195 145 155 225 143 137,5 155 155 67,5 RVCB11 340 200 295 260 160 210 300 175 150 225 175 47,5 RVCC11 330 260 395 380 165 320 390 300 225 15

TRASFORMATORI DI TENSIONE Norme CEI-UNEL, FASE-FASEVOLTAGE TRANSFORMERS CEI-UNEL STANDARDS, PHASE-PHASE

TERMINALI PRIMARIPRIMARY TERMINALS

DOPPIA CORRENTE PRIMARIADOUbLE PRIMARY CURRENT

Page 14: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

289

- Dimensioni: norme CEI-UNEL 21007. Costruiti e provati secondo IEC 60044-2- Frequenza 50 o 60 Hz- Fattore di tensione 1,2 illimitato e 1,9/8h- Numero di secondari 2- Tensione nom. secondaria: Avvolgimento di misura/protezione:100:√3V Avvolgimento per tensione residua: 100:3 V- Installazione per internoA RICHIESTA- Terzo secondario - Doppio rapporto primario- Coprimorsettiera sigillabile - Tensione nom. secondaria: 110:√3 V - 110:3 V- In fase di offerta è necessario specificare tutti i dati tecniciESEMPI D’ORDINERVFB11 20R 1003 100R (20KV:√3 / 100:3 / 100:√3RVFB11 20R 15R 103 10R (20KV:√3 - 15KV:√3 / 100:3 / 100:√3

- Dimensions: CEI-UNEL 21007 std. Manufactured and tested: IEC 60044-2- Frequency 50 or 60 Hz- Rated voltage factor 1,2 continuous and 1,9/8h- Number of secondaries 2- Rated secondary voltage: Measuring or protective winding: 100:√3 V Residual voltage winding: 100:3 V- Indoor installationoN REQuEST- Third secondary - Double primary ratio- Sealable terminal cover - Rated secondary voltage: 110:√3 V - 110:3 V- During the offer it is necessary to specify all technical detailsoRDER ExamPlERVFB11 20R 1003 100R (20kV:√3 / 100:3 / 100:√3RVFB11 20R 15R 103 10R (20kV:√3 - 15kV:√3 / 100:3 / 100:√3

TRASFORMATORI DI TENSIONE Norme CEI-UNEL, FASE-TERRAVOLTAGE TRANSFORMERS CEI-UNEL STANDARDS, PHASE-GROUND

A

N

A

N

I

H

C

5

D

B

A

E

M6

M8

C

D

5

A

E B

M6

M8

I

H

GF

GF

LL

Ø11M10Ø11M10

A

N

A

N

I

H

C

5

D

B

A

E

M6

M8

C

D

5

A

E B

M6

M8

I

H

GF

GF

LL

Ø11M10Ø11M10

da dnna

N

Sec 1 Sec 2

A M10

Sec 1 Sec 2

da1 dnna1

da2 dnna2

Sec 1 Sec 2

da1 dnna1

da2 dnna2

A B

SECONDO / accoRDiNg To: IEC/CEI EN 60071-1

[mm] 12 kV 24 kV 36 kV A 120 220 320 B 120 220 320

12 kV - 24 kV - 36 kV

Dimensioni / Dimensions [mm] A B C D E F G H I L RVFA11 305 180 240 180 145 150 130 155 155 67,5 RVFB11 340 200 300 200 160 170 140 225 175 47,5 RVFC11 400 250 390 240 155 175 155 300 225 15

A

N

A

N

I

H

C

5

D

B

A

E

M6

M8

C

D

5

A

E B

M6

M8

I

H

GF

GF

LL

Ø11M10Ø11M10

A

N

A

N

I

H

C

5

D

B

A

E

M6

M8

C

D

5

A

E B

M6

M8

I

H

GF

GF

LL

Ø11M10Ø11M10

da dnna

N

Sec 1 Sec 2

RVFA11

Upn (kV) ≤ 12: 3Max. N° sec. 3

Kg. ~ 22

RVFB11

Upn (kV) ≤ 24: 3Max. N° sec. 3

Kg. ~ 30

RVFC11

Upn (kV) ≤ 36Max. N° sec. 2

Kg. ~ 50

DISTANZE DI MONTAGGIO MINIME MINIMUM ASSEMbLY DISTANCES

TERMINALI PRIMARIPRIMARY TERMINALS

DOPPIA CORRENTE PRIMARIADOUbLE PRIMARY CURRENT

RAPPORTO MINORE / loW RaTio RAPPORTO MAGGIORE / HigH RaTio

Page 15: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

290

A U

B V

A

B

Ø14 105

60

40

2

34

32

139

75

250

PG16

32

55 5

105

M10

100

5

Ø14 M10

M6

15 15

177,5 150

350

110

148

220

270

125

178

280

270

165

155

365

130

280

150

Sec 1 Sec 2

1b1a2 2a2 2b

1a1 1b 2a1 2b

M5

M5

Sec 1 Sec 2

1b1a2 2a2 2b

1a1 1b 2a1 2b

M5

M5

A U

B V

100

110

M10

- Dimensioni secondo norme DIN 42 600 TEIL 9- Costruiti e provati secondo IEC 60044-2- Frequenza 50 o 60 Hz- Fattore di tensione 1,2 per tempo illimitato - Numero di secondari 1- Tensione nominale secondaria 100 V- Installazione per interno- Morsetti secondari secondo DINA RICHIESTA- Secondario aggiuntivo - Doppio rapporto primario- Morsetti secondari ns. standard - Tensione nominale secondaria 110 V- In fase di offerta è necessario specificare tutti i dati tecniciESEMPI D’ORDINERVCAD1 10/10 (10000/100V)RVCBD1 20/10 (20000/100V)

- Dimensions according to DIN42 600 TEIL 9 standards - Manufactured and tested acc. to IEC 60044-2- Frequency 50 or 60 Hz- Rated voltage factor 1,2 continuous- Number of secondary 1- Rated secondary voltage 100 V- Indoor installation- Secondary terminal board according to DINoN REQuEST- Second secondary - Double primary ratio- Standard sec. terminal board - Rated secondary voltage 110 V- During the offer it is necessary to specify all technical detailsoRDER ExamPlERVCAD1 10/10 (10000/100V)RVCBD1 20/10 (20000/100V)

RVCAD1

Upn (kV) ≤ 12Max. N° sec. 2

Kg. ~ 22

RVCBD1

Upn (kV) ≤ 24Max. N° sec. 2

Kg. ~ 30

MORSETTI SECONDARI NORME DIN 12 kVSECONDARY TERMINALS DIN STANDARDS 12 kV

MORSETTI SECONDARI NOSTRO STANDARD 12 kVSTANDARD SECONDARY TERMINAL bOARD 12 kV

A U

B V

A

B

Ø14 105

60

40

2

34

32

139

75

250

PG16

32

55 5

105

M10

100

5

Ø14 M10

M6

15 15

177,5 150

350

110

148

220

270

125

178

280

270

165

155

365

130

280

150

A U

B V

A

B

Ø14 105

60

40

2

34

32

139

75

250

PG16

32

55 5

105

M10

100

5

Ø14 M10

M6

15 15

177,5 150

350

110

148

220

270

125

178

280

270

165

155

365

130

280

150

A U

B V

A

B

Ø14 105

60

40

2

34

32

139

75

250

PG16

32

55 5

105

M10

100

5

Ø14 M10

M6

15 15

177,5 150

350

110

148

220

270

125

178

280

270

165

155

365

130

280

150

TRASFORMATORI DI TENSIONE Norme DIN, FASE-FASEVOLTAGE TRANSFORMERS DIN STANDARDS

TERMINALI PRIMARIPRIMARY TERMINALS

DOPPIA CORRENTE PRIMARIADOUbLE PRIMARY CURRENT

RAPPORTO MINORE / loW RaTio RAPPORTO MAGGIORE / HigH RaTio

Page 16: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

291

A U A

Ø14 105

60

40

2

34

32

139

75

PG16

32

55 5

105

M10

5

Ø14

M6

M10

N

15 15

350350

177,5 150

250

148

220

125

270

365

155

270

280

150

280

178

A U A

Ø14 105

60

40

2

34

32

139

75

PG16

32

55 5

105

M10

5

Ø14

M6

M10

N

15 15

350350

177,5 150

250

148

220

125

270

365

155

270

280

150

280

178

A U A

Ø14 105

60

40

2

34

32

139

75

PG16

32

55 5

105

M10

5

Ø14

M6

M10

N

15 15

350350

177,5 150

250

148

220

125

270

365

155

270

280

150

280

178

BA

SECONDO / accoRDiNg To: IEC/CEI EN 60071-1

[mm] 12 kV 24 kV A 120 220 B 120 220

SECONDARY TERMINALS DIN STANDARDS 12 kV - 24 kVMORSETTI SECONDARI NORME DIN 12 kV - 24 kV

RVFAD1

Upn (kV) ≤ 12: √3Max. N° sec. 2

Kg. ~ 22

Sec 1

na2

a1 n

M5

M5

- Dimensioni: DIN 42 600 TEIL 9. Costruiti e provati secondo IEC 60044-2- Frequenza 50 o 60 Hz- Fattore di tensione 1,2 illimitato e 1,9/8h- Numero di secondari 2- Tensione nom. secondaria: avvolgimento di misura o protezione: 100:√3 V avvolgimento per tensione residua: 100:3 V- Installazione per interno, morsetti secondari secondo DINA RICHIESTA- Secondario aggiuntivo - Doppio rapporto primario- Tensione nominale secondaria: 110:√3 V - 110:3 V- In fase di offerta è necessario specificare tutti i dati tecniciESEMPI D’ORDINERVFAD1 10R 1003 100R (10kV:√3 / 100:3 / 100:√3RVFBD1 20R 15R 103 10R (20kV:√3 - 15kV:√3 / 100:3 / 100:√3

- Dimensions: DIN42 600 TEIL 9 std. Manufactured and tested: IEC 60044-2- Frequency 50 or 60 Hz- Rated voltage factor 1,2 continuous and 1,9/8h- Number of secondary 2- Rated secondary voltage: Measuring or protective winding: 100:√3 V Residual voltage winding: 100:3 V- Indoor installation, secondary terminal board according to DINoN REQuEST- Second secondary - Double primary ratio- Rated secondary voltage: 110:√3 V - 110:3 V- During the offer it is necessary to specify all technical detailsoRDER ExamPlERVFAD1 10R 1003 100R (10kV:√3 / 100:3 / 100:√3RVFBD1 20R 15R 103 10R (20kV:√3 - 15kV:√3 / 100:3 / 100:√3

TRASFORMATORI DI TENSIONE Norme DIN, FASE-TERRAVOLTAGE TRANSFORMERS DIN STANDARDS, PHASE-GROUND

TERMINALI PRIMARIPRIMARY TERMINALS

DOPPIA CORRENTE PRIMARIADOUbLE PRIMARY CURRENT

M10

A U

Sec 1

na2

a1 n

M5

M5

RAPPORTO MINOREloW RaTio

RAPPORTO MAGGIOREHigH RaTio

DISTANZE DI MONTAGGIO MINIME MINIMUM ASSEMbLY DISTANCES

RVFBD1

Upn (kV) ≤ 24: √3Max. N° sec. 2

Kg. ~ 30

STANDARD SECONDARY TERMINAL bOARD 12 kV - 24 kVMORSETTI SECONDARI NOSTRO STANDARD 12 kV - 24 kV

A U A

Ø14 105

60

40

2

34

32

139

75

PG16

32

55 5

105

M10

5

Ø14

M6

M10

N

15 15

350350

177,5 150

250

148

220

125

270

365

155

270

280

150

280

178

A U A

Ø14 105

60

40

2

34

32

139

75

PG16

32

55 5

105

M10

5

Ø14

M6

M10

N

15 15

350350

177,5 150

250

148

220

125

270

365

155

270

280

150

280

178

A U A

Ø14 105

60

40

2

34

32

139

75

PG16

32

55 5

105

M10

5

Ø14

M6

M10

N

15 15

350350

177,5 150

250

148

220

125

270

365

155

270

280

150

280

178

Page 17: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

292

A M10

BA

Sec 1 Sec 2

da1 dnna1

da2 dnna2

Sec 1 Sec 2

da1 dnna1

da2 dnna2

SECONDO / accoRDiNg To: IEC/CEI EN 60071-1

[mm] 12 kV 24 kV 36 kV A 120 220 320 B 120 220 320

- Costruiti e provati secondo IEC 60044-2- Frequenza 50 o 60 Hz- Fattore di tensione 1,2 illimitato e 1,9/8h- Numero di secondari 2- Tensione nom. secondaria: avvolgimento di misura o protezione: 100:√3 V avvolgimento per tensione residua: 100:3 V- Installazione per internoA RICHIESTA- Terzo secondario - Doppio rapporto primario- Coprimorsettiera sigillabile- Tensione nom. secondaria: 110:√3 V - 110:3 V- In fase di offerta è necessario specificare tutti i dati tecniciESEMPI D’ORDINERVFTS1 20R 1003 100R (20kV:√3 / 100:3 / 100:√3RVFCS1 20R 15R 103 10R (20kV:√3 - 15kV:√3 / 100:3 / 100:√3

- Manufactured and tested acc. to IEC 60044-2- Frequency 50 or 60 Hz- Rated voltage factor 1,2 continuous and 1,9/8h- Number of secondary 2- Rated secondary voltage: Measuring or protective winding: 100:√3 V Residual voltage winding: 100:3 V- Indoor installationoN REQuEST- Third secondary - Double primary ratio- Sealable terminal cover- Rated secondary voltage: 110:√3 V - 110:3 V- During the offer it is necessary to specify all technical detailsoRDER ExamPlERVFTS1 20R 1003 100R (20kV:√3 / 100:3 / 100:√3RVFCS1 20R 15R 103 10R (20kV:√3 - 15kV:√3 / 100:3 / 100:√3

TRASFORMATORI DI TENSIONE CON PORTA FUSIBILE, FASE-TERRAVOLTAGE TRANSFORMERS FUSE-HOLDER, PHASE-GROUND

TERMINALI PRIMARIPRIMARY TERMINALS

DOPPIA CORRENTE PRIMARIADOUbLE PRIMARY CURRENT

DISTANZE DI MONTAGGIO MINIME MINIMUM ASSEMbLY DISTANCES

RAPPORTO MINORE / loW RaTio RAPPORTO MAGGIORE / HigH RaTio

Page 18: TRASFORMATORI DI CORRENTE TOROIDAL CURRENT · di corrente norme cei-unel di corrente a mattonella di corrente norme din di tensione norme cei-unel, fase-fase di tensione norme cei-unel,

293

Dimensioni / dimensions [mm] A B C D E F G H I L M N RVFTS1 225 150 303 160 112,5 405 265 275 76 195 130 15 RVFBS1 225 150 338 180 112,5 517 300 309 76 195 130 15 RVFCS1 400 250 680 240 163 240 106 300 225 15

A

N

5

I N

M8

M6

M

L

H

A

G

D

B

C

F

E

M6

M

L

C

E

A

F

D

B

5

I

M6M8

N

N

Ø9

Ø11M10

da dnna

N

Sec 1 Sec 2

A

N

5

I N

M8

M6

M

L

H

A

G

D

B

C

F

E

M6

M

L

C

E

A

F

D

B

5

I

M6M8

N

N

Ø9

Ø11M10

da dnna

N

Sec 1 Sec 2

RVFTS1

Upn (kV) ≤ 17,5: √3Max. N° sec. 3

Kg. ~ 20

MORSETTI SECONDARI NOSTRO STANDARD 12 kV - 24 kV - 36 kVSTANDARD SECONDARY TERMINAL bOARD 12 kV - 24 kV - 36 kV

RVFBS1

Upn (kV) ≤ 24: √3Max. N° sec. 3

Kg. ~ 28

RVFCS1

Upn (kV) ≤ 36: √3Max. N° sec. 3

Kg. ~ 40