- data: 21/01/2008 - quota inizio: piano campagna
- località: Viale Europa 84 - Rivanazzano (PV) - prof. falda: non rilevata
Prof N°30 Nsptm n° colpi n° colpi
0,00 0 00,30 10 170,60 4 70,90 2 31,20 3 51,50 3 51,80 4 72,10 7 122,40 7 122,70 6 103,00 7 123,30 10 173,60 11 183,90 33 554,20 50 83
GRAFICO
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
SCPT 1
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50 60 70N30(n° colpi)
Pro
f. (m
)
Scpt 1
- data: 30/08/06
- quota inizio: piano campagna - località: Rivanazzano (PV) - Via Puccini - prof. falda: n.r
Prof N°30 Nspt LITO-
m n° colpi n° colpi STRATIGRAFIA
0,30 0 00,60 2 30,90 4 71,20 10 171,50 10 171,80 11 182,10 9 152,40 9 152,70 9 153,00 8 133,30 6 103,60 27 453,90 36 604,20 36 604,50 32 534,80 26 435,10 28 475,40 29 485,70 27 456,00 34 576,30 42 706,60 35 586,90 38 637,20 49 82
PROVA PENETROMETRICA DINAMICA SCPT 2LETTURE DI CAMPAGNA/VALORI DI RESISTENZA
GRAFICO
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50 60 70 80 90Nspt (n° colpi)
Pro
f. (m
)
- commitente: - data: 15/02/2006 - lavoro: - quota inizio: piano campagna - località: Rivanazzano - prof. falda: - note:
Prof N°30 Nspt LITO- GRAFICOm n° colpi n° colpi STRATIGRAFIA
0,00 0 00,30 1 20,60 2 30,90 2 31,20 2 31,50 2 31,80 3 52,10 4 72,40 4 72,70 5 83,00 5 83,30 5 83,60 5 83,90 5 84,20 4 74,50 4 74,80 4 75,10 4 75,40 3 55,70 3 5
PROVA PENETROMETRICA DINAMICA
LETTURE DI CAMPAGNA/VALORI DI RESISTENZASCPT 3
0
1
2
3
4
5
6
0 10 20 30N30 (n° colpi)
Pro
f. (m
)
PROVA PENETROMETRICA DINAMICA
LETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- commitente: - data: 15/07/2009 - lavoro: - quota inizio: piano campagna - località: RIVANAZZANO TERME - Via S.Giuseppe - prof. falda: - note:
Prof N°30 Nspt LITO-
m n° colpi n° colpi STRATIGRAFIA
0,00 0 00,30 5 80,60 6 100,90 4 71,20 3 51,50 3 51,80 2 32,10 3 52,40 2 32,70 2 33,00 2 33,30 3 53,60 3 53,90 3 54,20 4 74,50 4 74,80 5 85,10 7 125,40 8 135,70 16 276,00 5 86,30 5 86,60 6 106,90 6 107,20 5 87,50 5 87,80 5 88,10 5 88,40 6 108,70 6 109,00 6 109,30 7 12
GRAFICO
SCPT 4
0
1
2
3
4
5
6
7
8
9
10
11
12
0 10 20 30 40 50 60
Nspt
Pro
f. (m
)
PROVA PENETROMETRICA STATICA DIAGRAMMA DI RESISTENZA - commitente: - data: - lavoro: - quota inizio: Piano campagna - località: Rivanazzano - Via San Giuseppe - prof. falda: non rilevata
Prof LP LL RP=qc RL=fs Rf=fs/qcm Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 %
0,200,40 26 29 26,0 0,2 0,770,60 14 17 14,0 0,2 1,430,80 15 20 15,0 0,3 2,221,00 13 23 13,0 0,7 5,131,20 18 33 18,0 1,0 5,561,40 15 28 15,0 0,9 5,781,60 14 31 14,0 1,1 8,101,80 18 31 18,0 0,9 4,812,00 47 58 47,0 0,7 1,562,20 12 43 12,0 2,1 17,222,40 17 29 17,0 0,8 4,712,60 15 26 15,0 0,7 4,892,80 17 31 17,0 0,9 5,493,00 22 40 22,0 1,2 5,453,20 20 39 20,0 1,3 6,333,40 16 33 16,0 1,1 7,083,60 19 30 19,0 0,7 3,863,80 41 59 41,0 1,2 2,934,00 72 95 72,0 1,5 2,134,20 64 102 64,0 2,5 3,964,40 65 105 65,0 2,7 4,104,60 58 98 58,0 2,7 4,604,80 87 139 87,0 3,5 3,985,00 82 131 82,0 3,3 3,985,20 98 153 98,0 3,7 3,745,40 144 178 144,0 2,3 1,575,60 50 96 50,0 3,1 6,135,80 57 95 57,0 2,5 4,446,00 33 47 33,0 0,9 2,836,20 30 66 30,0 2,4 8,006,40 41 71 41,0 2,0 4,886,60 29 64 29,0 2,3 8,05
PENETROMETRO STATICO tipo PAGANI da 10t-Velocità Avanzamento punta di 2 cm/s
Punta meccanica tipo Begemann o=35.7 mm (area punta 10 cm2-apertura 60°) - Manicotto laterale (superfi cie 150 cm2)
CPT 5
Valori di resistenza
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- commitente: - data: 29/07/05 - lavoro: - quota inizio: p.c. - località: Rivanazzano (PV) - Nazzano - prof. falda: - note:
Prof N°30 Nsptm n° colpi n° colpi
0,30 6 100,60 6 100,90 6 101,20 10 171,50 7 121,80 9 152,10 8 132,40 8 132,70 6 103,00 6 103,30 6 103,60 5 83,90 6 104,20 7 124,50 10 174,80 8 135,10 15 255,40 11 18
SCPT 6
PROVA PENETROMETRICA DINAMICA
LETTURE DI CAMPAGNA - VALORI DI RESISTENZA
m n° colpi0,00 00,30 10,60 20,90 61,20 81,50 101,80 82,10 82,40 72,70 83,00 83,30 73,60 73,90 94,20 84,50 84,80 95,10 95,40 85,70 76,00 86,30 86,60 96,90 117,20 97,50 107,80 98,10 108,40 138,70 179,00 21
DATA: 31/03/2011 NOTE:
Prof N°30
COMMITTENTE: QUOTA INIZIO: p.c.
LOCALITA' : Rivanazzano (PV) PROFONDITA' FALDA: non rilevata
SCPT 7
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50
N°30
Pro
f. (m
)
GRAFICO
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- commitente: - data: 23/03/2005 - lavoro: - quota inizio: piano campagna - località: Strada Mulattieri - Rivanazzano (PV) - prof. falda: non rilevata
SCPT 8
Prof N°30 Nspt LITO- GRAFICOm n° colpi n° colpi STRATIGRAFIA
0,00 0 00,30 1 20,60 1 20,90 3 51,20 13 221,50 5 81,80 5 82,10 8 132,40 12 202,70 9 153,00 8 133,30 7 123,60 5 83,90 5 84,20 6 104,50 15 254,80 9 155,10 6 105,40 5 85,70 5 86,00 5 86,30 5 86,60 4 76,90 5 87,20 5 87,50 14 237,80 18 308,10 5 88,40 5 88,70 7 129,00 6 109,30 6 10
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30N30 (n° colpi)
Pro
f. (m
)
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- commitente: - data: 10/05/2006 - lavoro: - quota inizio: Piano campagna - località: Rivanazzano (PV) - Via Marconi - prof. falda: - note:
Prof N°30 Nsptm n° colpi n° colpi
0,00 0 00,30 3 50,60 5 80,90 5 81,20 5 81,50 8 131,80 12 202,10 39 652,40 27 452,70 29 483,00 33 553,30 39 653,60 44 733,90 36 604,20 47 78
SCPT 9
RIFIUTO
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- data: 07/05/2004 - quota inizio: piano campagna
- località: Via Marconi Rivanazzano (PV) - prof. falda: - note:
Prof N°30 GRAFICOm n° colpi
0,00 00,30 20,60 20,90 11,20 91,50 41,80 152,10 30
SCPT 10
0
1
2
3
0 5 10 15 20 25 30 35 40
N30 (n° colpi)
Pro
f. (m
)
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- commitente: - data: 12/05/2008 - lavoro: - quota inizio: - località: Rivanazzano (PV) - prof. falda: - note:
Prof N°30 Nspt LITO- GRAFICOm n° colpi n° colpi STRATIGRAFIA
0,00 0 00,30 11 180,60 7 120,90 7 121,20 5 81,50 4 71,80 14 232,10 19 322,40 12 202,70 11 183,00 14 233,30 13 223,60 5 83,90 5 84,20 7 124,50 9 154,80 11 185,10 15 255,40 21 355,70 24 406,00 26 436,30 28 476,60 30 506,90 35 587,20
SCPT 11
0
1
2
3
4
5
6
7
8
9
0 10 20 30 40N30
Pro
f. (m
)
rifiuto
- commitente: - data: 08/09/2009 - progetto : - quota inizio: 178 m s.l.m. circa - località: Rivanazzano - livello acquifero:
Prof N°30 Nsptm n° colpi n° colpi
0,00 0 00,30 10 170,60 10 170,90 4 71,20 3 51,50 3 51,80 6 102,10 4 72,40 5 82,70 8 133,00 4 73,30 5 83,60 5 83,90 5 84,20 7 124,50 8 134,80 10 175,10 7 125,40 6 105,70 6 106,00 6 106,30 6 106,60 5 86,90 4 77,20 4 77,50 6 107,80 10 178,10 10 178,40 13 228,70 14 239,00 20 339,30 25 42
- PENETROMETRO DINAMICO tipo PAGANI da 10t - Sistema di battitura - maglio kg 73
SCPT 12
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- commitente: - data: 08/09/2009 - progetto: - quota inizio: 178 m s.l.m. (quota C.T.R.) - località: Rivanazzano (PV) - prof. falda:
Prof LP LL RP=qc RL=fs qc/fsm Kg/cmq Kg/cmq Kg/cmq Kg/cmq
0,200,40 45 52 45,0 0,47 96,430,60 81 90 81,0 0,60 135,000,80 76 91 76,0 1,00 76,001,00 43 83 43,0 2,67 16,131,20 29 54 29,0 1,67 17,401,40 23 49 23,0 1,73 13,271,60 21 40 21,0 1,27 16,581,80 20 46 20,0 1,73 11,542,00 25 51 25,0 1,73 14,422,20 25 42 25,0 1,13 22,062,40 30 52 30,0 1,47 20,452,60 34 58 34,0 1,60 21,252,80 44 73 44,0 1,93 22,763,00 40 79 40,0 2,60 15,383,20 35 78 35,0 2,87 12,213,40 40 80 40,0 2,67 15,003,60 33 70 33,0 2,47 13,383,80 33 66 33,0 2,20 15,004,00 16 40 16,0 1,60 10,004,20 26 40 26,0 0,93 27,864,40 56 67 56,0 0,73 76,364,60 91 107 91,0 1,07 85,314,80 16 32 16,0 1,07 15,005,00 13 25 13,0 0,80 16,255,20 32 45 32,0 0,87 36,925,40 17 34 17,0 1,13 15,005,60 25 29 25,0 0,27 93,755,80 26 47 26,0 1,40 18,576,00 41 57 41,0 1,07 38,446,20 47 73 47,0 1,73 27,126,40 50 85 50,0 2,33 21,436,60 53 89 53,0 2,40 22,086,80 64 109 64,0 3,00 21,337,00 57 93 57,0 2,40 23,757,20 51 86 51,0 2,33 21,867,40 60 87 60,0 1,80 33,337,60 51 84 51,0 2,20 23,187,80 62 99 62,0 2,47 25,148,00 70 104 70,0 2,27 30,888,20 56 93 56,0 2,47 22,708,40 81 101 81,0 1,33 60,758,60 67 87 67,0 1,33 50,25
PENETROMETRO STATICO tipo PAGANI da 10t-Velocità Avanzamento punta di 2 cm/s
Punta meccanica tipo Begemann ο=35.7 mm (area punta 10 cmq-apertura 60°) - Manicot to laterale (superficie 150 cmq)
Valori di resistenza
DISANCORATO
PROVA PENETROMETRICA STATICA CPT 13
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA - VALORI DI RESISTENZA
QUOTA INIZIO: piano campagna
PROFONDITA' FALDA: non rilevata
NOTE:
m n° colpi n° colpi0,000,30 1 2 20,60 3 5 50,90 8 13 131,20 8 13 131,50 9 15 151,80 10 17 172,10 8 13 132,40 5 8 82,70 5 8 83,00 5 8 83,30 5 8 83,60 5 8 83,90 6 10 104,20 7 12 124,50 8 13 134,80 8 13 135,10 7 12 125,40 7 12 125,70 9 15 156,00 9 15 156,30 9 15 156,60 10 17 17
DATA: 28/12/2009
Prof N°30 Nspt ORIZZONTI
LOCALITA' : Rivanazzano Terme - Via Perosi
SCPT 14
COMMITTENTE:
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30
Nspt
Pro
f. (m
)
GRAFICO
- commitente: - data: 28/12/09 - lavoro: - quota inizio: da p.c. - località: Rivanazzano (PV) - Via Perosi - prof. falda:
Prof LP LL RP=qc RL=fs Rf=fs/qcm Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 %
0,200,40 5 10 5 0,3 6,670,60 7 11 7 0,3 3,810,80 8 14 8 0,4 5,001,00 22 32 22 0,7 3,031,20 36 52 36 1,1 2,961,40 45 53 45 0,5 1,191,60 41 64 41 1,5 3,741,80 41 69 41 1,9 4,552,00 40 71 40 2,1 5,172,20 37 69 37 2,1 5,772,40 42 72 42 2,0 4,762,60 40 70 40 2,0 5,002,80 43 78 43 2,3 5,433,00 47 86 47 2,6 5,533,20 45 82 45 2,5 5,483,40 51 87 51 2,4 4,713,60 59 98 59 2,6 4,413,80 52 100 52 3,2 6,154,00 49 90 49 2,7 5,584,20 48 84 48 2,4 5,00
PENETROMETRO STATICO tipo PAGANI da 10t-Velocità Avanzamento punta di 2 cm/s
Punta meccanica tipo Begemann o=35.7 mm (area punta 10 cm2-apertura 60°) - Manicotto laterale (superficie 150 cm2)
CPT 15
Valori di resistenza
PROVA PENETROMETRICA STATICA
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- commitente: - data: 06/10/2006 - lavoro: - quota inizio: piano campagna - località: Strada Priv. Tevere - Salice Terme - prof. falda: non rilevata
SCPT 16Prof N°30 Nspt GRAFICO
m n° colpi n° colpi
0,00 0 00,30 10 170,60 10 170,90 9 151,20 12 201,50 15 251,80 20 332,10 19 322,40 18 302,70 12 203,00 13 223,30 17 283,60 12 203,90 11 184,20 10 174,50 13 224,80 13 225,10 13 225,40 13 225,70 12 206,00 15 256,30 14 236,60 14 236,90 11 187,20 13 227,50 12 207,80 13 228,10 12 208,408,709,009,30
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30N30 (n° colpi)
Pro
f. (m
)
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- località: Rivanazzano (PV) - quota inizio: piano campagna - note: - prof. falda: N.R.
Prof N°30 Nsptm n° colpi n° colpi
0,00 0 00,30 4 70,60 10 170,90 14 231,20 21 351,50 29 481,80 23 382,10 25 422,40 20 332,70 43 723,00 50 83
SCPT 17
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- data: 04/06/2008 - quota inizio: piano campagna
- località: Rivanazzano (PV) - Via Colombo - prof. falda: - note:
Prof N°30 Nspt LITO- GRAFICOm n° colpi n° colpi STRATIGRAFIA
0,00 0 00,30 2 30,60 3 50,90 5 81,20 5 81,50 6 101,80 8 132,10 35 582,40 45 75
SCPT 18
PROVA PENETROMETRICA STATICA CPT 19 DIAGRAMMA DI RE SISTENZA
- quota inizio: da p.c. - località: Rivanazzano (PV) - prof. falda: n.r.
Prof LP LL RP=qc RL=fs Rf=fs/qcm Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 %
0,200,40 37 81 37 2,9 7,930,60 36 78 36 2,8 7,780,80 48 82 48 2,3 4,721,00 46 84 46 2,5 5,511,20 44 78 44 2,3 5,151,40 39 69 39 2,0 5,131,60 41 75 41 2,3 5,531,80 38 77 38 2,6 6,842,00 73 117 73 2,9 4,022,20 99 138 99 2,6 2,632,40 64 101 64 2,5 3,852,60 62 102 62 2,7 4,302,80 145 149 145 0,3 0,183,00 89 161 89 4,8 5,393,20 289 385 289 6,4 2,21
PENETROMETRO STATICO/ tipo PAGANI da 10t-Velocità Avanzamento punta di 2 cm/s
Punta meccanica tipo Begemann o=35.7 mm (area punta 10 cm2-apertura 60°) - Manicotto laterale (superficie 150 cm2)
Valori di resistenza
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- quota inizio: piano campagna - località: RIVANAZZANO - Via Pavesi - prof. falda: NON RILEVATA - note:
Prof N°30 Nspt LITO- GRAFICOm n° colpi n° colpi STRATIGRAFIA
0,00 0 00,30 12 200,60 3 50,90 2 31,20 1 21,50 2 31,80 7 122,10 14 232,40 18 302,70 21 353,00 24 403,30 29 483,60 29 483,90 26 434,20 26 434,50 28 47
SCPT 20
0
1
2
3
4
5
6
7
8
9
10
11
12
0 10 20 30 40 50 60
Nspt
Pro
f. (m
)
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- località: RIVANAZZANO - V.le Repubblica - quota inizio: piano campagna - note: - prof. falda: NON RILEVATA
Prof N°30 Nspt LITO- GRAFICOm n° colpi n° colpi STRATIGRAFIA
0,00 0 00,30 4 70,60 3 50,90 5 81,20 7 121,50 5 81,80 6 102,10 7 122,40 5 82,70 6 103,00 6 103,30 6 103,60 9 153,90 5 84,20 4 74,50 7 124,80 7 125,10 7 125,40 11 185,70 17 286,00 18 306,30 22 376,60 36 606,90 60 100
SCPT 21
0
1
2
3
4
5
6
7
8
9
10
11
12
0 10 20 30 40 50 60 70 80 90 100Nspt
Pro
f. (m
)
Rifiuto, rimbalzo netto
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA/VALORI DI RESISTENZA
- lavoro: P.I. Intervento "ex Albergo Grande" - data: 16/05/2007 - località: Rivanazzano (PV) - quota inizio: piano campagna
Prof N°30 Nspt LITO- GRAFICOm n° colpi n° colpi STRATIGRAFIA
0,00 0 00,30 5 80,60 9 150,90 17 281,20 20 331,50 18 301,80 19 322,10 20 332,40 19 322,70 16 273,00 14 233,30 19 323,60 21 353,90 12 204,20 10 174,50 10 174,80 7 125,10 8 135,40 28 475,70
RIFIUTO
SCPT 22
0
1
2
3
4
5
6
0 10 20 30 40 50 60 70 80 90 100Nspt
Pro
f. (m
)
PROVA PENETROMETRICA DINAMICALETTURE DI CAMPAGNA - VALORI DI RESISTENZA
QUOTA INIZIO: piano campagna
PROFONDITA' FALDA: 8.00 - 8.50 m da p.c.
NOTE:
m n° colpi n° colpi0,00 0 0 00,30 10 17 170,60 3 5 50,90 3 5 51,20 14 23 231,50 24 40 401,80 15 25 252,10 7 12 122,40 30 50 502,70 30 50 503,00 35 58 583,30 35 58 583,60 30 50 503,90 32 53 534,20 32 53 534,50 48 80 804,80 39 65 655,10 37 62 625,40 31 52 525,70 12 20 206,00 22 37 376,30 31 52 526,60
Prof N°30 Nspt ORIZZONTI
RIFIUTO
LOCALITA' : Terme di Rivanazzano
DATA: 29/01/2010
SCPT 23
0
1
2
3
4
5
6
7
0 10 20 30 40 50 60 70 80 90100
Nspt
Pro
f. (m
)
GRAFICO