Tipo lampada TL5 HE TL5 HO / TL5 HO TOP TL5 VHO TL5 Xtra TL5 C TL-D Eco TL-D TL-D X/XX TL MiniPotenza lamp. (W) 14 14 14 14 21 21 28 28 35 35 24 24 24 24 39 39 49 49 54 54 80 80 95 95 120 120 49 49 54 54 80 80 22 22 40 40 55 60 16 16 16 16 32 32 51 51 15 18 18 18 18 36 36 58 58 70 70 36 36 58 58 4 6 8 13
Tipo reattore Codice computerNumero lampade 1 2 3 4 1 2 1 2 1 2 1 2 3 4 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 1 1 2 3 4 1 2 1 2 1 1 2 3 4 1 2 1 2 1 2 1 2 1 2 1 1 1 1
HF-
P Pe
rfor
mer
EII
HF-P 1 14-35 TL5 HE EII 220-240V 50/60HZ HFP11435HEHF-P 2 14-35 TL5 HE EII 220-240V 50/60Hz HF2P21435HEHF-P 3/414 TL5 EII 220-240V 50/60HZ HFP3414HEHF-P 1 24-39 TL5 HO EII 220-240V 50/60HZ HFP12439HOHF-P 2 24-39 TL5 HO EII 220-240V 50/60Hz HF2P22439HOHF-P 3/424 TL5/PL-L EII 220-240V 50/60HZ HFP3424TL5HF-P 149 TL5 HO EII 220-240V 50/60HZ HFP149HOHF-P 249 TL5 HO EII 220-240V 50/60Hz HF2P249HOHF-P 154 TL5 HO EII 220-240V 50/60HZ HFP154HOHF-P 254 TL5 HO EII 220-240V 50/60Hz HF2P254HOHF-P 180 TL5/PL-L EII 220-240V 50/60HZ HFP180TL51HF-P 280 TL5/PL-L EII 220-240V 50/60HZ HFP280TL5HF-P 1 95-120 TL5 EII 220-240V HF2P195120VHOHF-P 2 95-120 TL5 EII 220-240V 50/60Hz HF2P295120VHOHF-P 1 22-42 PL-T/C/L/TL5C EII 220-240V HF2P12242PLT5CHF-P 2 22-42 PL-T/C/L/TL5C EII 220-240V HF2P22242PLT5CHF-P 155 TL5C 220-240V 50/60HZ HFP155TL5CHF-P 160 TL5C 220-240V 50/60HZ HFP160TL5CHF-P 118 TL-D EII 220-240V 50/60HZ HF2P118HF-P 218 TL-D EII 220-240V 50/60HZ HF2P218HF-P 3/418 TL-D EII 220-240V 50/60HZ HF2P3418HF-P 136 TL-D EII 220-240V 50/60Hz HF2P136HF-P 236 TL-D EII 220-240V 50/60Hz HF2P236HF-P 158 TL-D EII 220-240V 50/60HZ HF2P158HF-P 258 TL-D EII 220-240V 50/60HZ HF2P258HF-P 170 TL-D EII 220-240V 50/60HZ HF2P170HF-P 270 TL-D EII 220-240V 50/60HZ HF2P270
HFP
EII
inte
llige
nt HF-PI 1 14/21/24/39 TL5 HE/HO 220-240V HFPI11439TL5
HF-PI 2 14/21/24/39 TL5 HE/HO 220-240V HFPI21439TL5HF-PI 1 28/35/49/54 TL5 HE/HO 220-240V HFPI12854TL5HF-PI 2 28/35/49/54 TL5 HE/HO 220-240V HFPI22854TL5
HF-
P EI
I Xtr
eme
HF-P XT 149 TL5 EII 220-240V 50/60HZ HFPXT149TL5HF-P XT 249 TL5 EII 220-240V 50/60HZ HFPXT249TL5HF-P XT 154 TL5 EII 220-240V 50/60HZ HFPXT154TL5HF-P XT 254 TL5 EII 220-240V 50/60HZ HFPXT254TL5HF-P XT 180 TL5 EII 220-240V 50/60HZ HFPXT180TL5HF-P XT 280 TL5 EII 220-240V 50/60HZ HFPXT280TL5HF-P XT 136 TL-D EII 220-240V 50/60HZ HFPXT136HF-P XT 236 TL-D EII 220-240V 50/60HZ HFPXT236HF-P XT 158 TL-D EII 220-240V 50/60HZ HFPXT158HF-P XT 258 TL-D EII 220-240V 50/60HZ HFPXT258
HF-
R E
II R
egul
ator
Ana
logi
ci 1
-10V
HF-R 1 14-35 TL5 EII 220-240V 50/60Hz HF2R11435TL5HF-R 2 14-35 TL5 EII 220-240V 50/60Hz HF2R21435TL5HF-R 314 TL5 EII 220-240V 50-60HZ HF2R314TL5HF-R 414 TL5 EII 220-240V 50/60Hz HF2R414TL5HF-R 124 TL5/PL-L EII 220-240V 50/60Hz HF2R124TL5PLLHF-R 224 TL5/PL-L EII 220-240V 50/60Hz HF2R224TL5PLLHF-R 324 TL5/PL-L EII 220-240V 50-60HZ HF2R324TL5PLLHF-R 424 TL5/PL-L EII 220-240V 50/60Hz HF2R424TL5PLLHF-R 139 TL5 EII 220-240V 50/60Hz HF2R139TL5HF-R 239 TL5 EII 220-240V 50/60Hz HF2R239TL5PLLHF-R 149 TL5 EII 220-240V 50/60Hz HF2R149TL5HF-R 249 TL5 EII 220-240V 50/60Hz HF2R249TL5HF-R 154 TL5 EII 220-240V 50/60Hz HF2R154TL5HF-R 254 TL5 EII 220-240V 50/60Hz HF2R254TL5HF-R 180 TL5/PL-L EII 220-240V 50/60Hz HF2R180TL5HF-R 280 TL5/PL-L EII 220-240V 50/60Hz HFR280TL5HF-R 122 TL5C 220-240V 50/60HZ HFR122TL5CHF-R 140 TL5C 220-240V 50/60HZ HFR140TL5CHF-R 155 TL5C 220-240V 50/60HZ HFR155TL5CHF-R 160 TL5C 220-240V 50/60HZ HFR160TL5CHF-R 118 TL-D EII 220-240V 50/60Hz HF2R118HF-R 218 TL-D EII 220-240V 50/60Hz HF2R218HF-R 318 TL-D EII 220-240V 50/60Hz HF2R318TLDHF-R 418 TL-D EII 220-240V 50/60Hz HF2R418TLDHF-R 136 TL-D EII 220-240V 50/60Hz HF2R136HF-R 236 TL-D EII 220-240V 50/60Hz HF2R236HF-R 158 TL-D EII 220-240V 50/60Hz HF2R158HF-R 258 TL-D EII 220-240V 50/60Hz HF2R258
HF-
R E
II D
ALI
HF-R DALI 122 TL5C 220-240V 50/60HZ HFRD122TL5CHF-R DALI 140 TL5C 220-240V 50/60HZ HFRD140TL5CHF-R DALI 155 TL5C 220-240V 50/60HZ HFRD155TL5CHF-R DALI 160 TL5C 220-240V 50/60HZ HFRD160TL5C
HF-
R E
II R
egul
ator
Tou
ch &
DA
LI
HF-R TD 1 14-35 TL5 EII 220-240V 50/60Hz HFRTD11435TL5HF-R TD 2 14-35 TL5 EII 220-240V 50/60Hz HFRTD21435TL5HF-R TD 314 TL5 EII 220-240V 50/60Hz HFRTD314TL5HF-R TD 414 TL5 EII 220-240V 50/60Hz HFRTD414TL5HF-R TD 124 TL5/PL-L EII 220-240V HFRTD124TL5PLLHF-R TD 224 TL5/PL-L EII 220-240V HFRTD224TL5PLLHF-R TD 324 TL5/PL-L EII 220-240V HFRTD324TL5PLLHF-R TD 424 TL5/PL-L EII 220-240V HFRTD424TL5PLLHF-R TD 139 TL5 EII 220-240V 50/60HZ HFRTD139TL5HF-R TD 239 TL5 EII 220-240V 50/60Hz HFRTD239TL5HF-R TD 149 TL5 EII 220-240V 50/60Hz HFRTD149TL5HF-R TD 249 TL5 EII 220-240V 50/60HZ HFRTD249TL5HF-R TD 154 TL5 EII 220-240V 50/60Hz HFRTD154TL5HF-R TD 254 TL5 EII 220-240V 50/60Hz HFRTD254TL5HF-R TD 180 TL5/PL-L EII 220-240V HFRTD180TL5HF-R TD 280 TL5/PL-L EII 220-240V HFRTD280TL5HF-R TD 118 TL-D EII 220-240V 50/60Hz HFRTD118HF-R TD 218 TL-D EII 220-240V 50/60Hz HFRTD218HF-R TD 318 TL-D EII 220-240V 50-60HZ HFRTD318TLDHF-R TD 418 TL-D EII 220-240V 50/60Hz HFRTD418TLDHF-R TD 136 TL-D EII 220-240V 50/60Hz HFRTD136HF-R TD 236 TL-D EII 220-240V 50/60Hz HFRTD236HF-R TD 158 TL-D EII 220-240V 50/60Hz HFRTD158HF-R TD 258 TL-D EII 220-240V 50/60Hz HFRTD258
HF-
M R
ED
HF-M RED 124 SH TL/TL5/PL-L 230-240V HFMRED124SHF-M RED 113 SH PL-C/PL-S 230-240V HFMRED113SHF-M RED 109 SH TL/PL-S 230-240V HFMRED109SHF-M RED 118 SH PL-C/PL-T 230-240V HFMRED118SHF-M RED 114 SH TL/PL-S 230-240V HFMRED114S
HF-
M B
LUE
HF-M BLUE 114 SH TL/PL-S/PL-C 230-240V HFM114SHF-M BLUE 114 LH TL/PL-S/PL-C 230-240V HFM114LHF-M BLUE 121 LH TL5 230-240V HFM121LHF-M BLUE 128 LH TL5 230-240V HFM128LHF-M BLUE 124 LH TL/TL5/PL-L 230-240V HFM124LHF-M BLUE 124 SH TL/TL5/PL-L 230-240V HFM124SHF-M BLUE 105 SH TL/PL-S 230-240V NDHF-M BLUE 105 LH TL/PL-S 230-240V NDHF-M BLUE 109 SH TL/PL-S 230-240V HFM109SHF-M BLUE 109 LH TL/PL-S 230-240V HFM109L
Vantaggi del reattore elettronico HFMassimo risparmio energetico: •fino al 25% rispetto elettromagnetico.Minore surriscaldamento e maggiore •durata di vita.Miniaturizzazione e versioni multipotenza.•Tempi di accensione più rapidi •e senza sfarfallìo.
Tipo lampada PL-S 4p PL-R Eco PL-C 4p PL-T 4p PL-L PL-HPotenza lamp. (W) 5 7 9 11 14 14 17 17 10 13 13 18 18 26 26 13 13 18 18 26 26 32 32 42 42 57 18 18 24 24 24 24 36 36 40 40 55 55 80 80 60 85 120
Tipo reattore Codice computerNumero lampade 1 1 1 1 1 2 1 2 1 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 1 2 1 2 3 4 1 2 1 2 1 2 1 2 1 1 1
HF-
P Pe
rfor
mer
EII
HF-P 1 13-17 PL-T/C/R EII 220-240V HF2P11317PLTCR
HF-P 2 13-17 PL-T/C/R EII 220-240V HF2P21317PLTCR
HF-P 118 PL-T/C 220-240V 50/60HZ HF2P118PLTC
HF-P 218 PL-T/C EII 220-240V 50/60Hz HF2P218PLTC
HF-P 1 22-42 PL-T/C/L/TL5C EII 220-240V HF2P12242PLT5C
HF-P 2 22-42 PL-T/C/L/TL5C EII 220-240V HF2P22242PLT5C
HF-P 157 PL-T 220-240V 50/60HZ HFP157PLT
HF-P 3/424 TL5/PL-L EII 220-240V 50/60HZ HFP3424TL5
HF-P 136 PL-L EII 220-240V 50/60Hz HF2P136PLL
HF-P 236 PL-L EII 220-240V 50/60HZ HF2P236PLL
HF-P 140 PL-L EII 220-240V 50/60HZ HF2P140PLL
HF-P 240 PL-L EII 220-240V 50/60HZ HF2P240PLL
HF-P 155 PL-L EII 220-240V 50/60Hz HF2P155PLL
HF-P 255 PL-L EII 220-240V 50/60HZ HF2P255PLL
HF-P 180 TL5/PL-L EII 220-240V 50/60HZ HFP180TL51
HF-P 280 TL5/PL-L EII 220-240V 50/60HZ HFP280TL5
HF-P 1 60-120 PL-H 220-240V 50/60HZ HFP120PLH
HF-
R E
II R
egul
ator
Ana
logi
ci 1
-10V
HF-R 118 PL-T/C 220-240V 50/60HZ HFR118PLT
HF-R 218 PL-T/C 220-240V 50/60HZ HFR218PLT
HF-R 1 26-42 PL-T/C 220-240V 50/60HZ HF2R12642PLTC
HF-R 2 26-42 PL-T/C 220-240V 50/60HZ HF2R22642PLTC
HF-R 124 TL5/PL-L EII 220-240V 50/60Hz HF2R124TL5PLL
HF-R 224 TL5/PL-L EII 220-240V 50/60Hz HF2R224TL5PLL
HF-R 324 TL5/PL-L EII 220-240V 50-60HZ HF2R324TL5PLL
HF-R 424 TL5/PL-L EII 220-240V 50/60Hz HF2R424TL5PLL
HF-R 136 PL-L EII 220-240V 50/60Hz HF2R136PLL
HF-R 236 PL-L EII 220-240V 50/60Hz HF2R236PLL
HF-R 140 PL-L EII 220-240V 50/60Hz HF2R140PLL
HF-R 240 PL-L EII 220-240V 50/60HZ HF2R240PLL
HF-R 155 PL-L EII 220-240V 50/60Hz HF2R155PLL
HF-R 255 PL-L EII 220-240V 50/60Hz HF2R255PLL
HF-R 180 TL5/PL-L EII 220-240V 50/60Hz HF2R180TL5
HF-R 280 TL5/PL-L EII 220-240V 50/60Hz HFR280TL5
HF-
R E
II R
egul
ator
Tou
ch &
DA
LI
HF-R TD 1 14-17 PL-R EII 220-240V HFRTD1417PLR
HF-R TD 2 14-17 PL-R EII 220-240V HFRTD21417PLR
HF-R TD 118 PL-T/C EII 220-240V 50/60Hz HF2RTD118PLT
HF-R TD 218 PL-T/C EII 220-240V 50/60Hz HF2RTD218PLT
HF-R TD 1 26-42 PL-T/C EII 220-240V HF2RTD12642PLT
HF-R TD 2 26-42 PL-T/C EII 220-240V HF2RTD22642PLT
HF-R TD 124 TL5/PL-L EII 220-240V HFRTD124TL5PLL
HF-R TD 224 TL5/PL-L EII 220-240V HFRTD224TL5PLL
HF-R TD 324 TL5/PL-L EII 220-240V HFRTD324TL5PLL
HF-R TD 424 TL5/PL-L EII 220-240V HFRTD424TL5PLL
HF-R TD 136 PL-L EII 220-240V 50/60Hz HFRTD136PLL
HF-R TD 236 PL-L EII 220-240V 50/60Hz HFRTD236PLL
HF-R TD 140 PL-L EII 220-240V 50/60Hz HFRTD140PLL
HF-R TD 240 PL-L EII 220-240V 50/60Hz HFRTD240PLL
HF-R TD 155 PL-L EII 220-240V 50/60Hz HFRTD155PLL
HF-R TD 255 PL-L EII 220-240V 50/60Hz HFRTD255PLL
HF-R TD 180 TL5/PL-L EII 220-240V HFRTD180TL5
HF-R TD 280 TL5/PL-L EII 220-240V HFRTD280TL5
HF-
M R
ED
HF-M RED 109 SH TL/PL-S 230-240V HFMRED109S
HF-M RED 113 SH PL-S/PL-C 230-240V HFMRED113S
HF-M RED 118 SH PL-C/PL-T 230-240V HFMRED118S
HF-M RED 124 SH TL/TL5/PL-L 230-240V HFMRED124S
HF-
M B
LUE
HF-M BLUE 105 SH TL/PL-S 230-240V ND
HF-M BLUE 105 LH TL/PL-S 230-240V ND
HF-M BLUE 109 SH TL/PL-S 230-240V HFM109S
HF-M BLUE 109 LH TL/PL-S 230-240V HFM109L
HF-M BLUE 114 SH TL/PL-S/PL-C 230-240V HFM114S
HF-M BLUE 114 LH TL/PL-S/PL-C 230-240V HFM114L
HF-M BLUE 118 SH PL-C/PL-T 230-240V HFM118S
HF-M BLUE 124 SH TL/TL5/PL-L 230-240V HFM124S
HF-M BLUE 124 LH TL/TL5/PL-L 230-240V HFM124L
Possibilità di risparmio energetico Numero di alimentatori per interruttore di protezione/magnetotermico (MCB)
Garanzia Estesa Philips
Reattore elettronico per lampade fluorescenti Tutti i reattori elettronici per lampade fluorescenti di Philips, così come precisato alla sezione Termini e Condizioni, beneficiano automaticamente di una garanzia di 3 anni. La garanzia ha validità dalla data di acquisto del reattore.
Estendi
la tuagaranzia
ANNI DI GARANZIASENZA REGISTRAZIONE DEL PROGETTO3 ANNI DI GARANZIA
CON REGISTRAZIONE DEL PROGETTO5Reattore elettronico per lampade fluorescenti Tutti i reattori elettronici per lampade fluorescenti di Philips, così come precisato alla sezione Termini e Condizioni, beneficiano di una garanzia di 5 anni se utilizzati per progetti registrati, a condizione che vengano installate lampade conformi agli standard IEC.
Applicazioni, termini e condizioniPer richiedere l’estensione di garanzia vedi termini e condizioni del servizio e registra il progetto sul sito: www.lampsandgear.philips.com
È ora di cambiare il tuo reattore per lampade fluorescenti!Abbinamento lampada e reattore
Nr per MCB 16A tipo B
Nr per MCB 16A tipo C
Codice computer
HFP11435HE 28 48HF2P21435HE 28 48HFP3414HE 28 48HFP12439HO 28 48HF2P22439HO 28 48HFP3424TL5 12 20HFP149HO 28 48HF2P249HO 12 20HFP154HO 28 48HF2P254HO 12 20HFP180TL51 12 20HFP280TL5 12 20HF2P195120VHO 12 20HF2P295120VHO 6 10HF2P12242PLT5C 28 48HF2P22242PLT5C 12 20HFP155TL5C 28 48HFP160TL5C 28 48HF2P118 28 48HF2P218 28 48HF2P3418 12 20HF2P136 28 48HF2P236 28 48HF2P158 28 48HF2P258 12 20HF2P170 28 48HF2P270 12 20
HFPI11439TL5 34 58HFPI21439TL5 26 44HFPI12854TL5 34 58HFPI22854TL5 16 27
HFPXT149TL5 28 48HFPXT249TL5 12 20HFPXT154TL5 28 48HFPXT254TL5 12 20HFPXT180TL5 12 20HFPXT280TL5 8 14HFPXT136 28 48HFPXT236 28 48HFPXT158 28 48HFPXT258 12 20
HF2R11435TL5 28 48HF2R21435TL5 12 20HF2R314TL5 28 48HF2R414TL5 28 48HF2R124TL5PLL 28 48HF2R224TL5PLL 28 48HF2R324TL5PLL 12 20HF2R424TL5PLL 12 20HF2R139TL5 28 48HF2R239TL5PLL 12 20HF2R149TL5 28 48HF2R249TL5 12 20HF2R154TL5 28 48HF2R254TL5 12 20HF2R180TL5 12 20HFR280TL5 9 15HFR122TL5C 28 48HFR140TL5C 28 48HFR155TL5C 12 20HFR160TL5C 12 20HF2R118 28 48HF2R218 12 20HF2R318TLD 12 20HF2R418TLD 12 20HF2R136 28 48HF2R236 12 20HF2R158 28 48HF2R258 12 20
HFRD122TL5C 28 48HFRD140TL5C 28 48HFRD155TL5C 12 20HFRD160TL5C 12 20
Nr per MCB 16A tipo B
Nr per MCB 16A tipo C
Codice computer
HFRTD11435TL5 28 48HFRTD21435TL5 12 20HFRTD314TL5 28 48HFRTD414TL5 28 48HFRTD124TL5PLL 28 48HFRTD224TL5PLL 28 48HFRTD324TL5PLL 12 20HFRTD424TL5PLL 12 20HFRTD139TL5 28 48HFRTD239TL5 12 20HFRTD149TL5 28 48HFRTD249TL5 12 20HFRTD154TL5 28 48HFRTD254TL5 12 20HFRTD180TL5 12 20HFRTD280TL5 9 15HFRTD118 28 48HFRTD218 12 20HFRTD318TLD 12 20HFRTD418TLD 12 20HFRTD136 28 48HFRTD236 12 20HFRTD158 28 48HFRTD258 12 20
HF2P11317PLTCR 28 48HF2P21317PLTCR 28 48HF2P118PLTC 28 48HF2P218PLTC 28 48HF2P12242PLT5C 28 48HF2P22242PLT5C 12 20HFP157PLT 28 48HFP3424TL5 12 20HF2P136PLL 28 48HF2P236PLL 28 48HF2P140PLL 28 48HF2P240PLL 12 20HF2P155PLL 28 48HF2P255PLL 12 20HFP180TL51 12 20HFP280TL5 12 20HFP120PLH 10 17
HFR118PLT 28 48HFR218PLT 28 48HF2R12642PLTC 28 48HF2R22642PLTC 12 20HF2R124TL5PLL 28 48HF2R224TL5PLL 28 48HF2R324TL5PLL 12 20HF2R424TL5PLL 12 20HF2R136PLL 28 48HF2R236PLL 12 20HF2R140PLL 28 48HF2R240PLL 12 20HF2R155PLL 28 48HF2R255PLL 12 20HF2R180TL5 12 20HFR280TL5 9 15
HFRTD1417PLR 28 48HFRTD21417PLR 28 48HF2RTD118PLT 28 48HF2RTD218PLT 28 48HF2RTD12642PLT 28 48HF2RTD22642PLT 12 20HFRTD124TL5PLL 28 48HFRTD224TL5PLL 28 48HFRTD324TL5PLL 12 20HFRTD424TL5PLL 12 20HFRTD136PLL 28 48HFRTD236PLL 12 20HFRTD140PLL 28 48HFRTD240PLL 12 20HFRTD155PLL 28 48HFRTD255PLL 12 20HFRTD180TL5 12 20HFRTD280TL5 9 15
E D C B A
100%90%
70%60%
30%
TLD Standard (alofosfati)
Reattore elettromagnetico
Ricambio lampada
MASTERTL-D Eco
Sostituzionedel reattore
HF-Performerper TL-D
Rinnovo impianto
Incasso Smartform
MASTER TL5HF- Performer
Sistemi di controllo
ActilumeHF-Regulator
Risparmio energetico-10%-25%
-15%-50%
Tipo lampada CDM CDO SON SON-i SON-H SOX-E (PSG) SOX (PSG) MHN-SA MHN-
LAMHN-
FC HPI(-T) (Plus) HPL-4/N/Comfort
Potenza lamp. (W) 35 70 150 250 50 70 100 150 250 50 70 100 150 250 400 600 600 1000 50 70 68 110 220 350 18 26 36 66 91 131 35 55 90 135 180 1800 1800 2000 1000 2000 1000 2000 250 400 1000 2000 2000 50 80 125 250 400
Tipo reattore Accenditore Collegam. Condensatore Codice computer 230V 400V 230V 400V 400V 230V 400V
BMH 35 L407-ITS 230/240V 50Hz SN(D) 58/ SN 58 T5 Semi-p. 6 μF/ 250V BMH35L407ITS
BMH 70 L407-ITS 230/240V 50Hz SN(D) 58/ SN 58 T5 Semi-p. 12 μF/ 250V BMH70L407ITS
BMH 35 L407-ITS 230/240V 50Hz SU 40 S Serie 6 μF/ 250V BMH35L407ITS
BMH 70 L407-ITS 230/240V 50Hz SU 40 S Serie 12 μF/ 250V BMH70L407ITS
BSN 50 L407-ITS 230/240V 50Hz BC1-118 SN(D )57/ SN 57 T5 Semi-p. 10 μF/ 250V BSN50L407ITS
BSN 50 L33-TS 230V 50Hz HD1-118 SN(D )57/ SN 57 T5 Semi-p. 10 μF/ 250V Su richiesta
BSN 50/70 L407-TS 230/240V 50Hz BC1-118 SU 10 S Serie 10 μF/ 250V BSN5070L407TS
BSN 70 L407-ITS 230/240V 50Hz BC1-118 SN(D) 57/ SN 57 T5 Semi-p. 12 μF/ 250V BSN70L407ITS
BSN 70 L33-TS 230V 50Hz HD1-118 SN(D) 57/ SN 57 T5 Semi-p. 12 μF/ 250V BSN70L33TS
BSN 50/70 L407-TS 230/240V 50Hz BC1-118 SU 10 S Serie 12 μF/ 250V BSN5070L407TS
BSN 100 L407-ITS 230/240V 50Hz BC1-123 SN(D) 58/ SN 58 T5 Semi-p. 12 μF/ 250V BSN100L407ITS
BSN 100 L33-TS 230V 50Hz HD1-123 SN(D) 58/ SN 58 T5 Semi-p. 12 μF/ 250V BSN100TS
BSN 100 L407-ITS 230/240V 50Hz BC1-123 SU 40 S Serie 12 μF/ 250V BSN100L407ITS
BSN 150 L407-ITS 230/240V 50Hz BC2-134 SN(D) 58/ SN 58 T5 Semi-p. 20 μF/ 250V BSN150L407ITS
BSN 150 L33-TS 230V 50Hz HD2-126 SN(D) 58/ SN 58 T5 Semi-p. 20 μF/ 250V BSN150TS
BSN 150 L407-ITS 230/240V 50Hz BC2-134 SU 40 S Serie 20 μF/ 250V BSN150L407ITS
BSN 250 L407-ITS 230/240V 50Hz BC2-160 SN(D) 58/ SN 58 T5 Semi-p. 32 μF/ 250V BSN250L407ITS
BSN 250 L33-TS 230V 50Hz HD2-151 SN(D) 58/ SN 58 T5 Semi-p. 32 μF/ 250V BSN250TS
BSN 250 L407-ITS 230/240V 50Hz BC2-160 SU 40 S Serie 32 μF/ 250V BSN250L407ITS
BSN 400 L407-ITS 230/240V 50Hz BC3-166 SN(D) 58/ SN 58 T5 Semi-p. 45 μF/ 250V BSN400L407ITS
BSN 400 L33-TS 230V 50Hz HD3-166 SN(D) 58/ SN 58 T5 Semi-p. 45 μF/ 250V BSN400TS
BSN 600 L407-ITS 230/240V 50Hz BC3-166 SN(D) 58/ SN 58 T5 Semi-p. 60 μF/ 250V Su richiesta
BSN 600 L309-ITS 400V 50Hz BC3-166 SND 88/ SND 89 Semi-p. 20 μF/ 450V Su richiesta
BSN 1000 L78 230/240V 50Hz HP-257 SN 56/ SN 59 Semi-p. 100 μF/ 250V BSN1000L78
BSN 50 L407-ITS 230/240V 50Hz BC1-118 X X 10 μF/ 250V BSN50L407ITS
BSN 50 L33-TS 230V 50Hz HD1-118 X X 10 μF/ 250V Su richiesta
BSN 70 L407-ITS 230/240V 50Hz BC1-118 X X 12 μF/ 250V BSN70L407ITS
BSN 70 L33-TS 230V 50Hz HD1-118 X X 12 μF/ 250V BSN70L33TS
BHL 50/80 L407 230/240V 50Hz BC1-118 X X 8 μF/ 250V Su richiesta
BHL 50/80 L302 230V 50Hz X X 8 μF/ 250V BHL5080L302
BHL 50/80 L48 230V 50Hz HD1-118 X X 8 μF/ 250V Su richiesta
BHL 50/80 L407 230/240V 50Hz BC1-118 X X 7μF/ 250V Su richiesta
BHL 50/80 L302 230V 50Hz X X 7μF/ 250V BHL5080L302
BHL 50/80 L48 230V 50Hz HD1-118 X X 7μF/ 250V Su richiesta
BHL 80/125 L407 230/240V 50Hz BC1-118 X X 10 μF/ 250V Su richiesta
BHL 125 L202 230V 50Hz X X 10 μF/ 250V BHL125L202
BHL 80/125 L48 230V 50Hz HD1-118 X X 10 μF/ 250V Su richiesta
BHL 250 L307 230/240V 50Hz BC2-134 X X 18 μF/ 250V Su richiesta
BHL 250 L202 230V 50Hz X X 18 μF/ 250V BHL250L202
BHL 250 L40 230V 50Hz HD2-126 X X 18 μF/ 250V BHL250
BHL 400 L307 230/240V 50Hz BC2-160 X X 25 μF/ 250V Su richiesta
BHL 400 L202 230 50Hz X X 25 μF/ 250V BHL400L202
BHL 400 L40 230V 50Hz HD2-151 X X 25 μF/ 250V BHL400
BSX 18 L80 230V 50Hz BC0-155 SX 26 Parallel 4,5 μF/ 250V BSX18L80
BSX 26 L80 230V 50Hz BC0-196 SX 26 Parallel 6 μF/ 230V BSXL80
BSX 36 H66 230-240V 50Hz CW-173/44 SX 72 Parallel 4,4 μF/ 300V Su richiesta
BSX 90 H26 220-230V 50Hz CW-173/52 SX 76 Parallel 7,6 μF/ 300V BSX90H26
BSX 91 H96 220-240V 50Hz CW-149/67 SX 74 Parallel 5,2 μF/ 300V BSX91H96
BSX 131 H96 220-240V 50Hz CW-178/74 SX 131 Parallel 3,4 μF/ 650V BSX131
BSX 35 L81 230V 50Hz BC0-196 SX 26 Parallel 8 μF/ 250V Su richiesta
BSX 35 L40 230V 50Hz HD1-118 SX 26 Parallel 8 μF/ 250V Su richiesta
BSX 55 H26 220-230V 50Hz CW-173/44 SX 72 Parallel 5,7 μF/ 450V BSX55H26
BSX 90 H26 220-230V 50Hz CW-173/52 SX 70 Parallel 7,6 μF/ 300V BSX90H26
BSX 90 L40 230V 50Hz HD1-118 SX 76 Parallel 10 μF/ 230V Su richiesta
BSX 135 H96 230-240V 50Hz CW-149/67 SX 74 Parallel 6,8 μF/ 420V BSX135
BSX 180 H96 220-240V 50Hz CW-178/78 SX 73 Parallel 4,4 μF/ 650V BSX180
BMH 1800 L78 230/240V 50Hz HP-317 SN 56/ SN 59/ SN 61 Semi-p. 200 μF/ 250V BMH1800L78
BMH 1800 L78 230/240V 50Hz HP-317 SN 56/ SN 59/ SN 61 Semi-p. 100 μF/ 250V BMH1800L78
BMH 2000 L76 380/400/415V 50Hz HP-317 380MZN2000 X 75 μF/ 450V Su richiesta
BHD 2000 L76 380/400/415V 50Hz HP-317 380MZN2000 X 70 μF/ 450V BHD2000L76
BHD 2000 L76 380/400/415V 50Hz HP-317 380MZN2000 X 65 μF/ 450V BHD2000L76
BHD 2000 L76 380/400/415V 50Hz HP-317 380MZN2000 X 65 μF/ 250V BHD2000L76
BHL 250 L307 230/240V 50Hz BC2-134 SI 51 Parallel 18 μF/ 250V Su richiesta
BHL 250 L40 230V 50Hz HD2-126 SI 51 Parallel 20 μF/ 250V BHL250
BHL 400 L307 230/240V 50Hz BC2-160 SI 51 Parallel 25 μF/ 250V Su richiesta
BHL 400 L40 230V 50Hz HD2-151 SI 51 Parallel 25 μF/ 250V BHL400
BHL 1000 L78 230/240V 50Hz HP-207 SI 52 Parallel 65 μF/ 250V BHL1000L78
BHL 2000 L78 230/240V 50Hz SI 52 Parallel 125 μF/ 250V BHL2000L78
BHL 2000 L50 380/400V 50Hz HP-257 SI 54 Parallel 35 μF/ 450V Su richiesta
Reattori convenzionali elettromeccanici e accenditori per lampade a scarica
Tipo lampada
CDM-T (Elite)/TC (Elite)/TP/TD/
R111/R
CDM-Tm/CDM-R111
20W/CDM-Rm
SDW-TG MHN/W-TD CPO CDO SON SOX-E SOX
Potenza lamp. (W) 35 35 70 150 20 35 50 100 70 150 45 60 90 140 70 100 150 70 100 150 36 66 91 35 55
Tipo reattore Codice computerNumero lampade 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Prim
avis
ion
Com
pact
HID-PV C 35 /G CDM 220-240V 50/60Hz HIDCPVSS035G
HID-PV C 035/I CDM 220-240V 50/60HZ HIDCPVSS035I
HID-PV C 35 /S CDM 220-240V 50/60Hz HIDCPV035S
HID-PV C 2x35 /G CDM 220-240V 50/60Hz HIDCPV235G
HID-PV C 2x35 /I CDM 220-240V 50/60Hz HIDCPV235I
HID-PV C 2x35 /S CDM 220-240V 50/60Hz HIDCPV235S
HID-PV C 70 /G CDM 220-240V 50/60Hz HIDCPVSS070G
HID-PV C 70 /I CDM 220-240V 50/60Hz HIDCPVSS070I
HID-PV C 70 /S CDM 220-240V 50/60Hz HIDCPV070S
HID-PV C 150 /G CDM 220-240V 50/60Hz HIDCPV150G
HID-PV C 150 /I CDM 220-240V 50/60Hz HIDCPV150I
HID-PV C 150 /S CDM 220-240V 50/60Hz HIDCPV150S
Prim
avsi
on m
ini HID-PV m 20 /G CDM LPF 220-240V 50/60Hz HIDPVM020G
HID-PV m 1x020/I mCDM LPF 220-240V HIDPVM020I
HID-PV m 1x020/S CDM HPF 220-240V HIDPVM020HPFS
HID-PV m 35 /G CDM 220-240V 50/60Hz HIDPVM035G
HID-PV m 1x035/I CDM 220-240V 50/60Hz HIDPVM035I
HID-PV m 1x035/S CDM HPF 220-240V HIDPVM035S
HID
-PV
SD
W
HID-PV 50 /G SDW-TG 220-240V 50/60Hz HIDPVC050GSDW
HID-PV C 50 /S SDW-TG 220-240V 50/60HZ HIDPVC050SDW
HID-PV 100 /G SDW-TG 220-240V 50/60Hz HIDPVC100GSDW
HID-PV C 100 /S SDW-TG 220-240V 50/60Hz HIDPVC100SDW
HID
-PV
X
trem
e HID-PV Xt 45 /S CPO-TW 220-240V 50/60Hz HIDPVXCPO45W
HID-PV Xt 60 /S CPO-TW 220-240V 50/60Hz HIDPVXCPO60W
HID-PV Xt 90 /S CPO-TW 220-240V 50/60Hz HIDPVXCPO90W
HID-PV Xt 140 /S CPO-TW 220-240V 50/60Hz HIDPVXCPO140W
HID
Dyn
avis
ion
Lu
mis
tep
HID-DV LS-10 Xt 60 /S CPO-TW 220-240V HIDDVL10XCPO60S
HID-DV LS-8 Xt 60 /S CPO-TW 220-240V HIDDVL8XCPO60S
HID-DV LS-6 Xt 60 /S CPO-TW 220-240V HIDDVL6XCPO60S
HID-DV LS-10 Xt 90 /S CPO-TW 220-240V HIDDVL10XCPO90S
HID-DV LS-8 Xt 90 /S CPO-TW 220-240V HIDDVL8XCPO90S
HID-DV LS-6 Xt 90 /S CPO-TW 220-240V HIDDVL6XCPO90S
HID-DV LS-10 Xt 140 /S CPO-TW 220-240V HIDDVL10XCPO140S
HID-DV LS-8 Xt 140 /S CPO-TW 220-240V HIDDVL8XCPO140S
HID-DV LS-6 Xt 140 /S CPO-TW 220-240V HIDDVL6XCPO140S
HID
-PV
SO
N/C
DO HID-PV 70 /S SON/CDO 220-240V 50/60Hz HIDPV070SON
HID-PV 100 /S SON/CDO 220-240V 50/60Hz HIDPV100SON
HID-PV 150 /S SON/CDO 220-240V 50/60Hz HIDPV150SON
HID
-Dyn
avis
ion
SON
/CD
O
HID-DV 1-10V 70 /S CDO 220-240V 50/60HZ HIDDV70CDO
HID-DV 1-10V 100 /S CDO 220-240V 50/60HZ HIDDV100CDO
HID-DV 1-10V 150 /S CDO 220-240V 50/60HZ HIDDV150CDO
HID-DV DALI 100-150 /S CDO/SON/SDW HIDDV100150
HID-DV 1-10V 70 /S SON 220-240V 50/60HZ HIDDV070
HID-DV 1-10V 100 /S SON 220-240V 50/60HZ HIDDV100
HID-DV 1-10V 150 /S SON 220-240V 50/60HZ HIDDV150
EXC
SO
X
EXC 36 SOX-E 220-240V 50/60HZ EXC036S50NEW
EXC 66 SOX-E 220-240V 50/60HZ EXC066S50NEW
EXC 91 SOX-E 220-240V 50/60HZ EXC091S50NEW
EXC 35 SOX 220-240V 50/60HZ EXC035S50NEW
EXC 55 SOX 220-240V 50/60HZ EXC055S50NEW
È ora di cambiare il tuo reattore per lampade a scarica!Abbinamento lampada e reattore
Garanzia Estesa Philips
Vantaggi del reattore elettronicoRisparmio energetico•Assenza di sfarfallìo•Stabilità di colore tra diverse lampade•Assenza di ronzìo•Esclusione automatica della lampada a fine vita•
Note sui reattori elettromeccanici per lampade a scarica
Note sui reattori elettronici per lampade a scarica
Sistemi di alimentazioneSono possibili tre tipologie di sistema con connessione in semi-parallelo, serie e parallelo (vedi disegni).
Nel sistema semi-parallelo (ad impulsi) l’accenditore è collegato in parallelo alla lampada ma con un collegamento addizionale tra alimentatore ed accenditore (che risulterà a tre fili). L’accenditore quindi utilizza una porzione dell’alimentatore per generare la corrente di spunto necessaria per l’accensione della lampada.
Nel collegamento in serie (a sovrapposizione), l’accenditore lavora autonomamente dall’alimentatore dal momento che ha un filamento di rame al suo interno che funge da trasformatore (l’accenditore sarà a due fili).
Vantaggi del sistema semi-paralleloNel sistema in semi-parallalo l’accenditore non è percorso da corrente una volta che la lampada è in funzionamento. Questo comporta riduzione della potenza assorbita e assenza di surriscaldamento dell’accenditore. Nel collegamento in serie con la lampada, l’accenditore è sempre fonte di assorbimento di potenza.Il collegamento in semi-parallelo consente elevate distanze tra lampada ed alimentatore (max. 20m), a differenza del collegamento in serie (max. 2m) per via della differenza della corrente di spunto prodotta.L’assenza di trasformatore nell’accenditore in semi-parallelo non genera fastidioso ronzìo.
Gli alimentatori della classe BSN per lampade SON e CDM sono quindi in grado di essere connessi in semi-parallelo e generare l’elevata corrente di spunto necessaria.
Termo SwitchGli alimentatori caratterizzati dalla connotazione “TS” nel codice prodotto sono provvisti di un sistema in grado di rilevare aumenti eccessivi della temperatura nell’avvolgimento di rame all’interno del corpo dell’alimentatore e provvedere quindi allo spegnimento automatico della lampada. Il sistema TS è obbligatorio per lampade compatte a bruciatore ceramico CDM. Per lampade tipo SON a vapori di sodio è obbligatorio per la norma europea sugli apparecchi EN60598.
AccenditoriPer lampade tipo CDM e SON sono disponibili versioni digitali in grado di rilevare lo stato di fine vita della lampada (SND per alimentazione in semiparallelo, SUD per alimentazione in serie).Per lampade CDM sono inoltre disponibili versioni temporizzate T5/T15 con timer per spegnere la lampada dopo 5 o 15 minuti in caso di guasto.
Reattore per lampade a scarica HID Tutti i reattori elettronici HID di Philips beneficiano automaticamente di una garanzia di 3 anni. La garanzia ha validità dalla data di acquisto del reattore.
Estendi
la tuagaranzia
ANNI DI GARANZIASENZA REGISTRAZIONE DEL PROGETTO3 ANNI DI GARANZIA
CON REGISTRAZIONE DEL PROGETTO5Reattore per lampade a scarica HID Tutti i reattori elettronici HID di Philips beneficiano di una garanzia di 5 anni se utilizzati per progetti registrati, a condizione che vengano installate lampade conformi agli standard IEC.
Applicazioni, termini e condizioniPer richiedere l’estensione di garanzia vedi termini e condizioni del servizio e registra il progetto sul sito: www.lampsandgear.philips.com
SOFT START In un impianto realizzato con alimentatori elettronici tutte le lampade si accendono contemporaneamente; la corrente di spunto in presenza di alimentatori elettronici necessaria per accendere le lampade è maggiore rispetto al caso in cui l’alimentazione sia tradizionale Cu-Fe. Questo riduce il numero massimo di alimentatori consentiti per interruttore automatico di protezione (interrutore magnetotermico). La funzionalità SOFT START è ideale per la sostituzione di alimentatori tradizionali Cu-Fe con soluzioni elettroniche in installazioni tipiche come faretti con lampade a scarica. Limitando la corrente di spunto, SOFT START consente di mantenere l’attuale configurazione dell’impianto elettrico e sostituire gli alimentatori uno ad uno senza investimenti aggiuntivi in interruttori automatici e cablaggi extra.Philips HID-PrimaVision con SOFT START consente la sostituzione uno ad uno da reattore tradizionale Cu-Fe ad elettronico HF; il numero massimo di alimentatori consentiti per interruttore automatico di protezione è infatti determinato solo dalla potenza di sistema.
SOFT START• consente di utilizzare meno interruttori automatici, riducendo il costo di installazione.Il collegamento passante• riduce i costi iniziali di installazione (semplificando i cablaggi) collegando un reattore al successivo.Un impianto alimentato ancora con reattori •convenzionali Cu-Fe ha una struttura analoga; questo consente il passaggio a reattore elettronico senza ri-cablaggi dispendiosi.
Versioni StandardIl nuovo HID-PrimaVision Compact è anche disponibile nell’esecuzione Standard per il montaggio integrato all’interno di apparecchi di illuminazione. Per consentire una migliore integrazione all’interno dell’apparecchio è stato ottimizzato il comportamento termico dell’alimentatore. Le versioni Standard non presentano la funzionalità Soft Start e non consentono il collegamento passante dell’alimentazione.
Sistema in serie
Versione S
Sistema in parallelo
Sistema semi-parallelo
Versione I (disponibili anche in versione precablata “G”)