Post on 29-Aug-2020
Sezionatori di linea Sezionatori di linea ed anelli di dred anelli di drenaggioenaggioSpectacle flanges and drip rings
INDICE INDEX
DRIP RINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 111CLASS 150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . “ 112CLASS 300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . “ 113CLASS 600. . . . . . . . . . . . . . . . . . . . . . . . . . . . . “ 114CLASS 900. . . . . . . . . . . . . . . . . . . . . . . . . . . . . “ 115CLASS 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . “ 116CLASS 2500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . “ 117CLASS 150 MALE-FEMALE RING TYPE . . . . . . . . 118-119CLASS 300 MALE-FEMALE RING TYPE . . . . . . . . 120-121CLASS 600 MALE-FEMALE RING TYPE . . . . . . . . 122-123CLASS 900 MALE-FEMALE RING TYPE . . . . . . . . 124-125CLASS 1500 MALE-FEMALE RING TYPE . . . . . . . 126-127CLASS 2500 MALE-FEMALE RING TYPE . . . . . . . 128-129
SEZIONASEZIONATORI DI LINEA TORI DI LINEA ED ANELLI DI DRENAGGIOED ANELLI DI DRENAGGIOSPECTACLE FLANGES AND DRIP RINGS
111
ANELLI DI DRENAGGIODRIP RINGS
CLASSECLASS150
SELEZIONATORI DI LINEAPER FLANGE CON FACCIA A SEMPLICE RISALTO SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RAISED FACE FLANGES
112
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Optional raised face may be specified by the purchaser.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS300
SELEZIONATORI DI LINEAPER FLANGE CON FACCIA A SEMPLICE RISALTO SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RAISED FACE FLANGES
113
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Optional raised face may be specified by the purchaser.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS600
SEZIONATORI DI LINEAPER FLANGE CON FACCIA A SEMPLICE RISALTO O PIANESPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RAISED FACE OF FLAT FACE FLANGES
114
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Optional raised face may be specified by the purchaser.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
115
CLASSECLASS900
SEZIONATORI DI LINEAPER FLANGE CON FACCIA A SEMPLICE RISALTO O PIANESPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RAISED FACE OF FLAT FACE FLANGES
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Optional raised face may be specified by the purchaser.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS1500
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
116
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Optional raised face may be specified by the purchaser.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
117
CLASSECLASS2500
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Optional raised face may be specified by the purchaser.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS150
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
118
TIPO MASCHIO MALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Oval or octagonal ring shapes may be provided; only the oval ring is illustrated for simplicity. Ring dimensions shall be in
accordance with ASME B16.20 except Th = T + t where T is the ring height specified in ASME B16.20.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS150
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
119
TIPO FEMMINA FEMALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Female ring-joint groove dimensions shall be in accordance with ASME B16.5.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS300
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
120
TIPO MASCHIO MALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Oval or octagonal ring shapes may be provided; only the oval ring is illustrated for simplicity. Ring dimensions shall be in
accordance with ASME B16.20 except Th = T + t where T is the ring height specified in ASME B16.20.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS300
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
121
TIPO FEMMINA FEMALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Female ring-joint groove dimensions shall be in accordance with ASME B16.5.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS600
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
122
TIPO MASCHIO MALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Oval or octagonal ring shapes may be provided; only the oval ring is illustrated for simplicity. Ring dimensions shall be in
accordance with ASME B16.20 except Th = T + t where T is the ring height specified in ASME B16.20.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS600
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
123
TIPO FEMMINA FEMALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Female ring-joint groove dimensions shall be in accordance with ASME B16.5.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS900
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
124
TIPO MASCHIO MALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Oval or octagonal ring shapes may be provided; only the oval ring is illustrated for simplicity. Ring dimensions shall be in
accordance with ASME B16.20 except Th = T + t where T is the ring height specified in ASME B16.20.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS900
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
125
TIPO FEMMINA FEMALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Female ring-joint groove dimensions shall be in accordance with ASME B16.5.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS1500
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
126
TIPO MASCHIO MALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Oval or octagonal ring shapes may be provided; only the oval ring is illustrated for simplicity. Ring dimensions shall be in
accordance with ASME B16.20 except Th = T + t where T is the ring height specified in ASME B16.20.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS1500
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
127
TIPO FEMMINA FEMALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Female ring-joint groove dimensions shall be in accordance with ASME B16.5.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS2500
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
128
TIPO MASCHIO MALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Oval or octagonal ring shapes may be provided; only the oval ring is illustrated for simplicity. Ring dimensions shall be in
accordance with ASME B16.20 except Th = T + t where T is the ring height specified in ASME B16.20.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.
CLASSECLASS2500
SELEZIONATORI DI LINEAPER FLANGE CON GIUNTO AD ANELLO METALLICO (R.T.J.)SPECTACLE FLANGES - SINGLES BLINDS - RING SPACERFOR RING JOINT TYPE FLANGES
129
TIPO FEMMINA FEMALE RING TYPE
GENERAL NOTE: dimensions are in millimeters.
NOTES:1. Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole and located such that it will not
interfere with bolting between two flanges.2. Female ring-joint groove dimensions shall be in accordance with ASME B16.5.3. The thickness of the web (or tie bar) dimension Wt, shall be 0.25 inch (6,4 millimeter) minimum, except when t is less
than 0.25 inch, Wt shall equal t.