Trafoelettro catalogo resina

8
TRANSFORMATORI IN RESINA CAST RESIN TRANSFORMERS

description

Transformadores en resina de 50 kvas a 20 MVas < 36 Kv

Transcript of Trafoelettro catalogo resina

Page 1: Trafoelettro catalogo resina

TRANSFORMATORI IN RESINACAST RESIN TRANSFORMERS

rafael
Pie_pdf
rafael
Irecyl
Page 2: Trafoelettro catalogo resina

TRAFO ELETTRO progetta e realizza trasformatori elettrici

con avvolgimenti inglobati sottovuoto in resina epossidica. Un

successo iniziato nel 1969 come piccolo laboratorio artigiano

e consolidatosi negli anni in un’ industria leader nel settore

dell’elettromeccanica.

I progressi tecnologici raggiunti in questi ultimi anni, nonchè

l’esperienza e le soluzioni costrutttive adottate, oltre i moderni

impianti e macchinari hanno permesso di ottenere un prodotto

con un elevato grado di affidabiltà.

Range da 25 kVA a 16 MVA con tensioni di fino a 36 kV.

TRAFO ELETTRO designs and manufactures electric transformers

with cast resin windings casted under vacuum with epoxy resin.

Starting our entrepreneurial success in 1969 as a small artisan

laboratory and consolidating it as a leader industry in this field.

The technological process reached in the latest years, as well as the

experience and the manufacturing solution adopted, other than last

generation plants available, have permitted to obtain a product of high

reliability.

Range of power from 25kVA to 16 MVA with voltages up to 36 kV.

Caratteristiche generali

General features

Page 3: Trafoelettro catalogo resina

ApplicazioniApplications

Essendo gli avvolgimenti di media tensione

completamente inglobati, i trasformatori che ne

risultano sono completamente protetti contro l’umidità,

polvere e depositi da ambiente fortemente inquinato,

conseguentemente non necessitano di climatizzazione

dell’ambiente di installazione, ne di particolare

manutenzione.

Applicazioni industriali consigliate:

laminatoi, fonderie, raffinerie, piattaforme galleggianti,

miniere, metropolitane ecc...

Dato l’impiego di materiali difficilmente infiammabili

ed autoestinguenti i trasformatori in resina sono

particolarmente adatti anche per applicazioni civili

quali: ospedali, cliniche, banche, grandi magazzini,

supermercati, centrali nucleari ed ambienti ad alto

contenuto ecologico, ecc...

As the high voltage windings are totally casted, the

cast resin transformers are totaly screened out against

moisture, dust and industrial waste due to heavily polluted

environment. This is why they do not require to be installed

in any airconditioned premises and are maintenance-free.

Suitable industrial applications: rolling mills, foundries,

refineries, offshore platforms, mines, undergrounds etc...

Due to the flame-resistant and self-extinguishing materials

used, cast resin transformers are particularly suitable

also for special applications like: hospitals, clinics, banks,

commercial buildings, supermarkets, nuclear plants,

skyscrapers and high ecological environments, etc...

Page 4: Trafoelettro catalogo resina

Caratteristiche costruttiveManufacturing features

Nucleo Magnetico

Il nucleo è costituito da lamierino magnetico a grani orientati isolati in carlyte,

a basse perdite, con taglio mitrato o Step-Lap, onde consentire una notevole

riduzione del livello di rumore e delle perdite a vuoto. Successivamente viene

bloccato da robusti profilati in acciaio e trattato tramite zincatura a caldo, al fine

di garantire maggior robustezza e stabilità in caso di sollecitazioni dovute alla

movimentazione ed agli sforzi di corto circuito.

Avvolgimenti di Bassa Tensione

Gli avvolgimenti di B.T. sono costituiti da lamina di alluminio elettrolitico,

opportunamente isolato con materiale pre-preg, impregnati in resina sintetica

in classe “H” ed essiccati in forno. Ciò assicura un’elevata resistenza alle

sollecitazioni di corto circuito. I terminali di uscita, sono costituiti da piatti in

alluminio a mezzo saldatura automatica e ancorati all’armatura da opportuni

distanziatori. A richiesta è possibile realizzare avvolgimenti in rame o con

caratteristiche su specifica (es.: disposizione dei terminali per allacciamento alla

blindosbarra, ecc...).

Avvolgimenti di Media Tensione

L’avvolgimento di M.T. è costituito da una serie di bobine in nastro di alluminio

elettrolitico aventi spigoli arrotondati e isolate con film di materiale poliestere. Una

volta completato il singolo avvolgimento viene ancorato con reti in fibra di vetro e,

dopo un adeguato ciclo di essiccamento, gli avvolgimenti vengono inglobati sotto

vuoto con resina epossidica in classe “F” opportunamente caricata con quarzo e

allumina triidrata. Inoltre ad ogni ciclo vengono effettuate analisi calorimetriche

a campione per verificare la transizione vetrosa. Le prese di regolazione vengono

ricavate nella mezzeria dell’avvolgimento e le varie posizioni si ottengono tramite

lo spostamento degli appositi ponticelli in ottone.

Magnetic core

The magnetic core is manufactured with grain oriented low-losses laminations,

insulated with carlyte, mitred type or step-lap, in order to considerably reduce the

sound level and the noload losses. It is clamped by steel yokes hot zinc coated and

treated in order to guarantee high sturdiness and stability during movements or in

case of to the short-circuit stresses.

Low voltage windings

The L.V. windings consist of electrolytic aluminium foils, insulated by pre preg

material, impregnated with “H“ class epoxy resin and heat treated in an oven to

form a compact unit with sufficient strength to withstand short-circuit forces in the

transformer. The L.V. terminals are produced with aluminium bars through automatic

welding and fixed to the upper yoke clamping frame by suitable spacers. On request

it is possible to manufacture copper windings or on customer’s specification (i.e.:

terminals arrangement for connection of busbars, etc...).

High Voltage windings

The H.V. windings are manufactured with overlapped coils in aluminium strips,

connected in series, with rounded corners and insulated with polyester material films.

Once the single winding is completed the entire coil is anchored by glass fiber

net and after a suitable drying cycle, all windings are casted under vacuum with

epoxy resin “F” class mixed with quartz and trihydrated alumina. Moreover, for each

production cicle is sampled with calorimetric analysis to test the vitreous transition.

The adjustment holds are obtained directly in the middle part of the winding and the

various positions are made thought brass bridges.

Page 5: Trafoelettro catalogo resina

InstallazioneInstallation

L’installazione dei trasformatori in resina TRAFO

ELETTRO è semplice e rapida. Non essendo necessarie

opere edili o strutture aggiuntive, la sicurezza

dell’installazione è garantita seguendo le semplici

indicazioni che vengono elencate nel manuale d’uso ed

installazione fornito assieme al trasformatore.

Inoltre, la sinergia tra le varie società che forniscono i

materiali correlati al trasformatore (es.: condotti sbarre,

interruttori ecc...) fa sì che l’installazione sia ancora

più facile coordinando e progettando su misura tutte le

varie apparecchiature che vengono predisposte in fase

di progetto.

TRAFO ELETTRO cast resin transformers are easy and rapid

to install. As constructive works or additional structures are

not required, the installation security is guaranteed by simple

indications listed in the technical and user manual supplied

together with the transformer.

Moreover, the existing sinergy between the various company

suppling the materials related to the transformers (es.: bus

bars, switches, etc...) facilitates the installation because all

the components are desigend and realized on customer

requirements.

Page 6: Trafoelettro catalogo resina

Condizioni ambientaliEnvironmental conditions

Classi ambientaliEnvironmental classes

Classi climaticheClimatic classes

Resistenza al fuocoFire comportment classes

E0

Nessuna condensa e inquinamento

trascurabili, installazioni all’interno in

ambiente pulito e asciutto

C1

Trasformatore atto a funzionare a

temperature ambiente non inferiori a

-5 °C, ma può essere immagazzinato

a temperature ambiente fino a 25°C

F0

Non è previsto un particolare

rischio d’incendio e non vengono

presi accorgimenti per limitare

l’infiammabilità

No negligible condensation and

pollution, indorr installation in a dry

and clean environment

Transformer suitable to work at

ambient temperature not lower than

-5 °C, but can be stored at ambient

temperatures up to -25 °C

Low fire risk level and are not required

particular flammability precautions

E1

Condensa occasionale e presenza di

modesto inquinamento

C2

Trasformatore atto a funzionare,

trasportabile ed immagazzinabile a

temperature ambiente di -25 °C

F1

Trasformatori soggetti a rischio

d’incendio e viene richiesta

un’infiammabilità ridotta. Il fuoco

deve estinguersi entro un tempo

determinato

Occasional condensation and low

pollution.

Transformer suitable to work,

transportable and storable at ambient

temperatures up to -25 °C

Medium/high fire risk and the

flammability level must be reduce.

Fire must be estinguished within a

specific time interval.

E2

Trasformatore soggetto a consistente

condensa o ad intenso inquinamento

o entrambi i fenomeni

High condensation, intense pollution

or both the conditions mixed

together

Tutti i trasformatori prodotti da TRAFO ELETTRO sono costruiti in accordo

con le Norme IEC 60076-11 (HDL 464 S1 1988), per caratteristiche di

autoestinguenza.

All TRAFO ELETTRO transformers are manufactured in accordance with

IEC 60076-11 (HDL 464-S1 1988) standards, for self-extinguishing

characteristics.

E2 C2 F1

Page 7: Trafoelettro catalogo resina

Punti di forza

Strengths

Scariche parziali ridotte ottenute grazie a un processo di inglobamento innovativo

Reduced partial discharges obtained thanks to a innovative casting process

Allungamento della vita dovuta a un basso livello di scariche parziali negli avvolgimenti

Longer life due to a lower partial discharge level on windings

Alta resistenza al cortocircuito grazie all’applicazione di fibre di vetro negli avvolgimenti

High resistance of short circuit efforts thanks to the application of fibber glass on windings

Miglior Efficienza rispetto ai tradizionali trasformatori, dovuta alle basse perdite

Low losses compared to the traditional transformers

Design specifico per aumentare l’aerazione degli avvolgimenti

Specific design in order to increase the cooling on the windings

Ingombro compatto frutto di una progettazione miratavolta ad ottimizzare materiali non perdendo di vita le esigenze nelle varie applicazioni

Reduced dimension through a designing aimed to optimized the materials and satisfy the needs of the work site

Page 8: Trafoelettro catalogo resina

ww

w.s

targ

raphic

.it

Via G.Galilei, 5 - 36071 Tezze d´Arzignano (VI) - Italy

TEL.+39 0444 482204 - FAX.+39 0444 483956 - E-mail: [email protected]

www.trafoelettro.com

TRASFORMATORI IN RESINACAST RESIN TRANSFORMERS