Palmare Hand controller -...

12
Palmare Hand controller PLASTIC SYSTEMS S.p.A. Via G. Marconi, 6 35010 BORGORICCO (PD) ITALY Tel. (+39) 049.9335901 - Fax (+39) 049.9335905 http: www.plasticsystems.it e-mail: [email protected] Caratteristiche Tecniche - Technical Specifications Peso W eight kg PALMARE/HAND CONTROLLER Grafico retroilluminato Backlift graphic display 0,7 Display

Transcript of Palmare Hand controller -...

Page 1: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

Palmare

Hand controller

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Caratteristiche Tecniche - Technical Specifications

PesoWeight kg

PA L M A R E /H A N D C O N T R O L L E R

Grafico retroilluminatoBacklift graphic display

0,7

Display

Page 2: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

Palmare

Hand controller

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Dimensioni - Dimensions

A

H

B

mm

mm

C mm

mm

PA L M A R E /H A N D C O N T R O L L E R

CO

D. 5

.45.

10.0

10.0

0 80

110

220

32

Abbinamenti - Combinations

Deumidificatori/Dryers

Deumidificatori DAC/DAC Dryer

Alimentatori individuali trifase/Three phase individual loaders

Net System 2

Termoregolatori stampo/Mould heaters

PA L M A R E /H A N D C O N T R O L L E R

Dosatori/Dosing Units

A C

H

B

Page 3: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

ValvoleProporzionali PV

PV Ratio Valves

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

P V 7 0

Caratteristiche Tecniche - Technical Specifications

Pressione di controllo/Required pressure

Consumo aria compressa ( x ciclo)Compressed air consumption ( x cycle)

Potenza assorbita/Absorbed power

Tensione-Frequen-z aTension-Frequency

P V 4 0 P V 6 0P V 5 0

tubazioni/Material pipe diameter mm

bar

NI

V/Hz

W

40

6-8

0,5

230V 50/60Hz24Vac 50/60Hz

24Vdc

5

50

6-8

0,5

230V 50/60Hz24Vac 50/60Hz

24Vdc

5

60

6-8

0,5

230V 50/60Hz24Vac 50/60Hz

24Vdc

5

70

6-8

0,5

230V 50/60Hz24Vac 50/60Hz

24Vdc

5

Page 4: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

Valvole Proporzionali PV

PV Ratio Valves

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Dimensioni - Dimensions

A

H

B

D

mm

mm

mm

mm

P V 4 0 P V 6 0 P V 7 0P V 5 0

CO

D. 5

.45.

10.0

02.0

0 355

161

272

40

355

161

272

50

355

161

272

60

355

161

272

70

A

B

H

D

D

Page 5: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

Valvole Proporzionalitemporizzate PVT

PVT Rat io Valveswith timer

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: info@plasticsy-

P V 7 0 T

Caratteristiche Tecniche - Technical Specifications

Pressione di controllo/Required pressure

Consumo aria compressa (x ciclo)Compressed air consumption (x cycle)

Potenza assorbita/Absorbed power

Tensione-Frequen-z aTension-Frequency

P V 4 0 T P V 6 0 TP V 5 0 T

tubazioni/Material pipe diameter mm

bar

NI

V/Hz

W

40

6-8

0,5

110-230Vac 50/60Hz

5

50

6-8

0,5

110-230Vac 50/60Hz

5

60

6-8

0,5

110-230Vac 50/60Hz

5

70

6-8

0,5

110-230Vac 50/60Hz

5

Page 6: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

Valvole Proporzionali temporizzate PVT

PVT Rat io Valves with timer

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Dimensioni - Dimensions

A

H

B

D

mm

mm

mm

mm

P V 4 0 T P V 6 0 T P V 7 0 TP V 5 0 T

CO

D. 5

.45.

10.0

03.0

0

355

161

272

40

355

161

272

50

355

161

272

60

355

161

272

70

E mm 120 120 120 120

F mm 120 120 120 120

G mm 80 80 80 80

A

EB

H

D

D

FG

Page 7: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

Griglie magnetiche

Magnetic grids

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Caratteristiche Tecniche - Technical Specifications

PesoWeight

E1C9/145 E2C15/182 Q2C7/170

MagnetiMagnets

kg

Neodimio/Neodimium

1,5

Neodimio/Neodimium

2,7

Neodimio/Neodimium

3

Page 8: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

Griglie magnetiche

Magnetic grids

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Dimensioni - Dimensions

A

H

B

mm

mm

mm

E1C9/145 Q2C7/170E2C15/182

CO

D. 5

.45.

10.0

07.0

0

88

145

40

88

182

40

170

170

45

H H H

A A

B

B B

A

Page 9: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Attacco universaleUniversal connection

Caratteristiche Tecniche - Technical Specifications

Peso/Weight kg

A U 1

Acciaio/S teel

2

A U 2

Acciaio/S teel

2,5

Materiale/Material

Page 10: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

PPLLAASSTTIICC SSYYSSTTEEMMSS SS..pp..AA..

Via G. Marconi, 6

35010 BORGORICCO (PD) ITALY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

AAttttaaccccoo uunniivveerrssaalleeUUnniivveerrssaall ccoonnnneeccttiioonn

DDiimmeennssiioonnii -- DDiimmeennssiioonnss

A (min-max)

C

H

I

d1 (N°xØ)

B

mm

mm

mm

mm

mm

mm

AAUU22AAUU11

CO

D. 5

.45.

10.0

0-.0

0

330-530

227

20

58

210

4xM6

58

280

4xM6

480-820

276

20

HH

dd

CC

BB

II

CC

AA

Page 11: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Dischi adattamentoAdapting discs

Caratteristiche Tecniche - Technical Specifications

Peso/Weight kg

DA1

Acciaio inox/Stainless steel

0,5

Materiale/Material

Page 12: Palmare Hand controller - plastservice.chplastservice.ch/WordPress/wp-content/uploads/2010/12/Zubehör.pdf · PALMARE/HAND CONTROLLER Dosatori/Dosing Units A C H B. Valvole Proporzionali

P L A S T I C S Y S T E M S S . p . A .

Via G. Marconi, 6

35010 BORGORICCO (PD) ITA LY

Tel. (+39) 049.9335901 - Fax (+39) 049.9335905

http: www.plasticsystems.it e-mail: [email protected]

Dischi adattamentoAdapting discs

Dimensioni - Dimensions

A

D

d 1 ( N x )

d 2 ( N x )

H

C

mm

mm

B mm

mm

mm

mm

mm

DA1

CO

D. 5

.45.

10.0

09.0

0

8xM6

8 x 9

1,5

300

280

210

190

C

H

d1 d2

D

B

A