NORMA ITALIANA CEI -...

54
Norma Italiana N O R M A I T A L I A N A CEI CNR CONSIGLIO NAZIONALE DELLE RICERCHE • AEI ASSOCIAZIONE ELETTROTECNICA ED ELETTRONICA ITALIANA Data Pubblicazione Edizione Classificazione Fascicolo COMITATO ELETTROTECNICO ITALIANO Titolo Title CEI EN 60617-7 1998-03 Seconda 3-19 4411 Segni grafici per schemi Parte 7: Apparecchiature e dispositivi di comando e protezione Graphical symbols for diagrams Part 7: Switchgear, controlgear and protective devices ELETTROTECNICA GENERALE E MATERIALI PER USO ELETTRICO NORMA TECNICA

Transcript of NORMA ITALIANA CEI -...

Norma Italiana

N O R M A I T A L I A N A C E I

CNR

CONSIGLIO NAZIONALE DELLE RICERCHE •

AEI

ASSOCIAZIONE ELETTROTECNICA ED ELETTRONICA ITALIANA

Data Pubblicazione

Edizione

Classificazione Fascicolo

COMITATOELETTROTECNICO

ITALIANO

Titolo

Title

CEI EN 60617-7

1998-03

Seconda

3-19 4411

Segni grafici per schemi

Parte 7: Apparecchiature e dispositivi di comando e protezione

Graphical symbols for diagrams

Part 7: Switchgear, controlgear and protective devices

ELETTROTECNICA GENERALE E MATERIALI PER USO ELETTRICO

NO

RM

A TE

CNIC

A

© CEI - Milano 1998. Riproduzione vietata.

Tutti i diritti sono riservati. Nessuna parte del presente Documento può essere riprodotta o diffusa con un mezzo qualsiasi senza il consenso scritto del CEI.Le Norme CEI sono revisionate, quando necessario, con la pubblicazione sia di nuove edizioni sia di varianti. È importante pertanto che gli utenti delle stesse si accertino di essere in possesso dell’ultima edizione o variante.

SOMMARIO

La presente Parte della Pubblicazione IEC 617 fa parte di una serie che tratta i segni grafici per schemi.Il campo di applicazione ed i riferimenti normativi di tale serie sono indicati nella Pubblicazione

IEC 617-1.

DESCRITTORI

• DESCRIPTORS

Apparecchiatura elettrica •

Electrical equipment;

Dispositivo di protezione •

Protective device;

Schema

elettrico •

Electric diagram;

Segno elettrico •

Electrical symbol;

COLLEGAMENTI/RELAZIONI TRA DOCUMENTI

Nazionali

Europei

(IDT) EN 60617-7:1996-06;

Internazionali

(IDT) IEC 617-7:1996;

Legislativi

INFORMAZIONI EDITORIALI

Norma Italiana

CEI EN 60617-7

Pubblicazione

Norma Tecnica

Carattere Doc.

Stato Edizione

In vigore

Data validità

1998-5-1

Ambito validità

Europeo

Varianti

Nessuna

Ed. Prec. Fasc.

702:1985

Comitato Tecnico

3-Documentazione e segni grafici

Approvata dal

Presidente del CEI

in Data

1998-2-18

CENELEC

in Data

1996-3-5

Sottoposta a

inchiesta pubblica come Documento originale

Chiusa in data

1995-11-15

Gruppo Abb.

1

Sezioni Abb.

A

Prezzo Norma IEC

96 SFr

ICS

01.080.30;

CDU

LEGENDA

(IDT) La Norma in oggetto è identica alle Norme indicate dopo il riferimento (IDT)

CENELEC members are bound to comply with theCEN/CENELEC Internal Regulations which stipulatethe conditions for giving this European Standard thestatus of a National Standard without any alteration.Up-to-date lists and bibliographical references con-cerning such National Standards may be obtained onapplication to the Central Secretariat or to anyCENELEC member.This European Standard exists in three official ver-sions (English, French, German).A version in any other language and notified to theCENELEC Central Secretariat has the same status asthe official versions.CENELEC members are the national electrotechnicalcommittees of: Austria, Belgium, Denmark, Finland,France, Germany, Greece, Iceland, Ireland, Italy, Lu-xembourg, Netherlands, Norway, Portugal, Spain,Sweden, Switzerland and United Kingdom.

I Comitati Nazionali membri del CENELEC sono tenu-ti, in accordo col regolamento interno del CEN/CENE-LEC, ad adottare questa Norma Europea, senza alcunamodifica, come Norma Nazionale.Gli elenchi aggiornati e i relativi riferimenti di tali Nor-me Nazionali possono essere ottenuti rivolgendosi alSegretario Centrale del CENELEC o agli uffici di qual-siasi Comitato Nazionale membro.La presente Norma Europea esiste in tre versioni uffi-ciali (inglese, francese, tedesco).Una traduzione effettuata da un altro Paese membro,sotto la sua responsabilità, nella sua lingua nazionalee notificata al CENELEC, ha la medesima validità.I membri del CENELEC sono i Comitati ElettrotecniciNazionali dei seguenti Paesi: Austria, Belgio, Dani-marca, Finlandia, Francia, Germania, Grecia, Irlanda,Islanda, Italia, Lussemburgo, Norvegia, Olanda, Por-togallo, Regno Unito, Spagna, Svezia e Svizzera.

© CENELEC Copyright reserved to all CENELEC members. I diritti di riproduzione di questa Norma Europea sono riservati esclu-sivamente ai membri nazionali del CENELEC.

Comitato Europeo di Normalizzazione Elettrotecnica European Committee for Electrotechnical Standardization

Comité Européen de Normalisation ElectrotechniqueEuropäisches Komitee für Elektrotechnische Normung

C E N E L E C

Secrétariat Central: rue de Stassart 35, B - 1050 Bruxelles

E u r o p ä i s c h e N o r m • N o r m e E u r o p é e n n e • E u r o p e a n S t a n d a r d • N o r m a E u r o p e a

EN 60617-7:1996-06

Segni grafici per schemi

Parte 7: Apparecchiature e dispositivi di comando e protezione

Graphical symbols for diagrams

Part 7: Switchgear, controlgear and protective devices

Symboles graphiques pour schémas

Partie 7: Appareillage et dispositifs de commande et de protection

Graphische Symbole für Schaltpläne

Teil 7: Schaltzeichen für Schalt- und Schutzeinrichtungen

CONTENTS INDICE

Rif. Topic Argomento Pag

.

NORMA TECNICACEI EN 60617-7:1998-03

Pagina iv

INTRODUZIONE

1

APPARECCHIATURE E DISPOSITIVI DI COMANDO E PROTEZIONE

2

NOTE GENERALI

2

SEGNI GRAFICI DISTINTIVI

2

CONTATTI

4

CONTATTI A DUE O TRE POSIZIONI

4

CONTATTI DI PASSAGGIO A DUE POSIZIONI

5

CONTATTI A FUNZIONAMENTO ANTICIPATO E RITARDATO

6

CONTATTI A RITARDO INTENZIONALE

7

CONTATTI A RITORNO AUTOMATICO ED A POSIZIONE MANTENUTA

8

AUSILIARI DI COMANDO, APPARECCHI DI MANOVRA E AVVIATORI

8

AUSILIARI DI COMANDO UNIPOLARI

9

AUSILIARI DI POSIZIONE

10

CONTATTI FUNZIONANTI PER EFFETTO DELLA TEMPERATURA

11

CONTATTI FUNZIONANTI PER EFFETTO DELLE VARIAZIONI DI VELOCITÀ E CONTATTI IN AMPOLLA DI MERCURIO

11

ESEMPI DI COMMUTATORI A PIÙ POSIZIONI INCLUSO L’ATTUATORE DI CONTROLLO

12

SEGNI GRAFICI A BLOCCO PER COMMUTATORI COMPLESSI

15

APPARECCHI DI MANOVRA E DI COMANDO

17

SEGNI GRAFICI A BLOCCO PER AVVIATORI DI MOTORI

20

RELÈ ELETTROMECCANICI A TUTTO O NIENTE

21

INTRODUCTION

P A R T / P A R T E

7

SWITCHGEAR, CONTROLGEAR AND PROTECTIVE DEVICES

CHAPTER/CAPITOLO

I

GENERAL RULES

SECTION/SEZIONE

1

QUALIFYNG SYMBOLS

CHAPTER/CAPITOLO

II

CONTACTS

SECTION/SEZIONE

2

CONTACTS WITH TWO OR THREE POSITIONS

SECTION/SEZIONE

3

PASSING CONTACTS WITH TWO POSITIONS

SECTION/SEZIONE

4

EARLY AND LATE OPERATING CONTACTS

SECTION/SEZIONE

5

CONTACTS WITH DELAYED OPERATION

SECTION/SEZIONE

6

AUTOMATIC RETURN AND NON-AUTOMATIC RETURN CONTACTS

CHAPTER/CAPITOLO

III

SWITCHES, SWITCHGEAR AND STARTERS

SECTION/SEZIONE

7

SINGLE-POLE SWITCHES

SECTION/SEZIONE

8

POSITION SWITCHES

SECTION/SEZIONE

9

TEMPERATURE SENSITIVE SWITCH

SECTION/SEZIONE

10

SPEED CHANGE SENSITIVE CONTACTS, MERCURY AND LEVELLING SWITCHES

SECTION/SEZIONE

11

EXAMPLES OF MULTI-POSITION SWITCHES, INCLUDING CONTROL SWITCHES

SECTION/SEZIONE

12

BLOCK SYMBOLS FOR COMPLEX SWITCHES

SECTION/SEZIONE

13

POWER SWITCHING DEVICES

SECTION/SEZIONE

14

BLOCK SYMBOLS FOR MOTOR STARTERS

CHAPTER/CAPITOLO

IV

ALL-OR-NOTHING RELAYS

NORMA TECNICACEI EN 60617-7:1998-03

Pagina v

SECTION/SEZIONE

15

OPERATING DEVICES

CHAPTER/CAPITOLO

V

MEASURING RELAYS AND RELATED DEVICES

SECTION/SEZIONE

16

BLOCK SYMBOL AND QUALIFYING SYMBOLS

SECTION/SEZIONE

17

EXAMPLES OF MEASURING RELAYS

SECTION/SEZIONE

18

OTHER DEVICES

CHAPTER/CAPITOLO

VI

PROXIMITY AND TOUCH-SENSITIVE DEVICES

SECTION/SEZIONE

19

SENSORS AND DETECTORS

SECTION/SEZIONE

20

SWITCHES

CHAPTER/CAPITOLO

VII

PROTECTIVE DEVICES

SECTION/SEZIONE

21

FUSES AND FUSE-SWITCHES

SECTION/SEZIONE

22

SPARK GAPS AND ARRESTERS

SECTION/SEZIONE

23

FIRE-EXTINGUISHERS

CHAPTER/CAPITOLO

VIII

MISCELLANEOUS SYMBOLS

SECTION/SEZIONE

24

IGNITERS AND FLAG-INDICATORS

SECTION/SEZIONE

25

STATIC SWITCHES

SECTION/SEZIONE

26

STATIC SWITCHING DEVICES

SECTION/SEZIONE

27

COUPLING DEVICES AND STATIC RELAYS, BLOCK SYMBOLS

ANNEX/ALLEGATO

A

OLDER SYMBOLS

ANNEX/ALLEGATO

B

ENGLISH ALPHABETIC INDEX

ANNEX/ALLEGATO

C ITALIAN ALPHABETIC INDEX

DISPOSITIVI DI COMANDO 21

RELÈ DI MISURA E DISPOSITIVI SIMILARI 24

SEGNI GRAFICI A BLOCCO E SEGNI GRAFICI DISTINTIVI 24

ESEMPI DI RELÈ DI MISURA 25

DISPOSITIVI VARI 27

DISPOSITIVI SENSIBILI ALLA PROSSIMITÀ O AL TOCCO 28

SENSORI 28

DISPOSITIVI DI CONTATTO 28

DISPOSITIVI DI PROTEZIONE 29

FUSIBILI ED INTERRUTTORI CON FUSIBILI 29

SPINTEROMETRI E SCARICATORI 30

ESTINTORI 31

SEGNI GRAFICI DIVERSI 31

BOBINE D’ACCENSIONE E INDICATORI A CARTELLINO 31

INTERRUTTORI STATICI 31

DISPOSITIVI STATICI DI CONNESSIONE 32

ACCOPPIATORI E RELÈ STATICI,SEGNI GRAFICI A BLOCCO 32

VECCHI SIMBOLI 33

INDICE ALFABETICO INGLESE 35

INDICE ALFABETICO ITALIANO 44

NORMA TECNICACEI EN 60617-7:1998-03Pagina vi

FOREWORDThe text of document 3A/385/FDIS, future edi-tion 2 of IEC 617-7, prepared by SC 3A, Graphi-cal symbols for diagram, of IEC TC 3, Docu-mentation and graphical symbols, wassubmitted to the IEC-CENELEC parallel vote andwas approved by CENELEC as EN 60617-7 on1996/03/05.

The following dates were fixed:

n latest date by which the EN has to be imple-mented at national level by publication ofan identical national Standard or by en-dorsement(dop) 1997/02/01

n latest date by which the national standardsconflicting with the EN have to be withdrawn(dow) 1997/02/01

ENDORSEMENT NOTICEThe text of the International StandardIEC 617-7:1996 was approved by CENELEC asa European Standard without any modification.

PREFAZIONEIl testo del documento 3A/385/FDIS, futura edi-zione 2 della Pubblicazione IEC 617-7, preparatodal SC 3A, Graphical symbols for diagram, del CTIEC 3, Documentation and graphical symbols, èstato sottoposto al voto parallelo IEC-CENELEC edè stato approvato dal CENELEC come Norma Eu-ropea EN 60617-7 in data 05/03/1996.

Sono state fissate le date seguenti:

n data ultima entro la quale la EN deve essereapplicata a livello nazionale mediante pubbli-cazione di una Norma nazionale identica omediante adozione(dop) 01/02/1997

n data ultima entro la quale le Norme nazionalicontrastanti con la EN devono essere ritirate(dow) 01/02/1997

AVVISO DI ADOZIONEIl testo della Pubblicazione IEC 617-7:1996 è statoapprovato dal CENELEC come Norma Europeasenza alcuna modifica.

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 1 di 48

INTRODUCTION

This part of IEC 617 forms an element of a se-ries which deals with graphical symbols for dia-grams.

The series consists of the following parts:

n Part 1: General information, general in-dex. Cross-reference tables

n Part 2: Symbol elements, qualifying sym-bols and other symbols havinggeneral application

n Part 3: Conductors and connecting de-vices

n Part 4: Basic passive componentsn Part 5: Semiconductors and electron tubesn Part 6: Production and conversion of elec-

trical energyn Part 7: Switchgear, controlgear and protec-

tive devicesn Part 8: Measuring instruments, lamps and

signalling devicesn Part 9: Telecommunications: Switching

and peripheral equipmentn Part 10: Telecommunications: Transmissionn Part 11: Architectural and topographical in-

stallation plans and diagramsn Part 12: Binary logic elementsn Part 13: Analogue elements

The scope and the normative references for thisseries are given in IEC 617-1.

Symbols have been designed in accordancewith requirements given in the future ISO11714-1(1). The module size M = 2,5 mm hasbeen used. For better readability smallersymbols in this standard have been en-larged to double size and are marked“200%”. in the symbol column. To savespace larger symbols have been reduced tohalf size and are marked “50%” in the sym-bol column. In accordance with the futureISO 11714-1, clause 7, symbol dimensions(for instance height) may be modified in or-der to make space for a greater number ofterminals or for other layout requirements.In all cases, whether the size is enlarged orreduced, or dimensions modified, the thick-ness of the original line should be main-tained without scaling.

The symbols in this standard are laid out insuch a way that the distance between connect-ing lines is a multiple of a certain module. Themodule 2M has been chosen to provideenough space for a required terminal designa-tion. The symbols have been drawn to a sizeconvenient for comprehension, using the samegrid consistently in the representation of allsymbols.(1) At present, at the stage of Draft International Standard (document

3/563/DIS).

INTRODUZIONE

La presente parte della Pubblicazione IEC 617 faparte di una serie che tratta i segni grafici perschemi.

Tale serie comprende le parti seguenti:

n Parte 1: Generalità - Indice generale - Ta-belle di corrispondenza

n Parte 2: Elementi dei segni grafici, segnigrafici e distintivi ed altri segni diuso generale

n Parte 3: Conduttori e dispositivi di connes-sione

n Parte 4: Componenti passivin Parte 5: Semiconduttori e tubi elettronicin Parte 6: Produzione, trasformazione e con-

versione dell’energia elettrican Parte 7: Apparecchiature e dispositivi di co-

mando e di protezionen Parte 8: Strumenti di misura, lampade e di-

spositivi di segnalazionen Parte 9: Telecomunicazioni: apparecchia-

ture di commutazione e periferichen Parte 10: Telecomunicazioni: trasmissionen Parte 11: Schemi e piani di installazione ar-

chitettonici e topograficin Parte 12: Elementi logici binarin Parte 13: Elementi analogici

Il campo di applicazione e i riferimenti normativi ditale serie sono indicati nella Pubblicazione IEC 617-1.

I segni grafici sono stati concepiti in conformità conle norme indicate nella norma futura ISO 11714-1(1).È stata utilizzata la dimensione del modulo M = 2,5mm. Nella presente norma, per migliorare la lettura,la dimensione dei segni grafici più piccoli è stata rad-doppiata e i segni grafici sono stati marcati “200%”nella colonna segno grafico. Per guadagnare spazio,la dimensione dei segni più grandi è stata dimezzatae i segni grafici sono stati marcati “50%” nella colonnasegno grafico. In conformità con la Norma futura ISO11714-1, articolo 7, è possibile modificare le dimen-sioni di un segno grafico (per esempio l’altezza) perguadagnare spazio ed aggiungere un maggior nume-ro di morsetti o per esigenze di impaginazione. Inogni caso, a prescindere che si tratti di riduzione o diingrandimento o di modifica delle dimensioni, sideve mantenere lo spessore originale del segno grafi-co senza cambiare la scala.

I segni grafici della presente Norma sono statipresentati in modo tale che la distanza tra i trattidi connessione sia un multiplo di un certo modu-lo. Il modulo 2M è stato scelto per riservare unospazio sufficiente all’identificazione necessaria deimorsetti. I segni grafici sono stati disegnati secon-do una misura idonea alla comprensione e utiliz-zando sempre la stessa griglia per la rappresen-tazione di tutti i segni grafici.(1) Attualmente è allo stadio di Bozza di Norma Internazionale (documento

3/563/DIS).

CEI EN 60617-7:1998-03

54

NORMA TECNICACEI EN 60617-7:1998-03Pagina 2 di 48

Tutti i segni grafici sono stati elaborati all’internodi una griglia con un sistema di elaborazione as-sistita dal calcolatore. La griglia utilizzata è statariprodotta sullo sfondo dei segni.

I simboli più vecchi che hanno fatto parte dell’ap-pendice A della prima edizione della Pubblica-zione IEC 617-7 per un periodo transitorio nonfanno più parte di questa seconda edizionepoichè saranno ritirati definitivamente dall’uso.

Gli indici delle Appendici B e C contengono unelenco alfabetico dei nomi dei segni grafici e deiloro numeri corrispondenti. I nomi dei segnigrafici si basano sulla descrizione dei segni graficidella presente parte. La Pubblicazione IEC 617-1contiene un indice generale con un elenco alfa-betico dei segni grafici di tutte le parti.

SEGNI GRAFICI PER SCHEMI

APPARECCHIATURE E DISPOSITIVI DI COMANDO E PROTEZIONE

NOTE GENERALI

Un piccolo cerchio, annerito o no, può essere ag-giunto al punto di articolazione di ognuno dei se-gni grafici, come indicato nell’esempio 07-02-02.

Questo cerchio è necessario per la comprensionedi alcuni segni, come per esempio, 07-02-05.

Per gli altri metodi di rappresentazione di appa-recchiature, in particolare le apparecchiatureelettroniche e complesse, vedere PubblicazioneIEC 617-12, sezione 17A e 29 e PubblicazioneIEC 617-13, sezione 17.

SEGNI GRAFICI DISTINTIVI

All symbols are designed within a grid in acomputer-aided draughting system. The gridwhich was used has been reproduced in thebackground of the symbols.

The older symbols which were included in ap-pendix A of the first edition of IEC 617-7 for atransitional period, are no longer part of thissecond edition, as they will definitely be with-drawn from use.

The indexes in Annex B and C include an al-phabetic list of symbol names and their corre-sponding number. The symbol names arebased on the description of the symbols ofthis part. A general index including an alpha-betic list of symbols of all parts is given inIEC 617-1.

GRAPHICAL SYMBOLS FOR DIAGRAMS

7 SWITCHGEAR, CONTROLGEAR

P A R T / P A R T E

AND PROTECTIVE DEVICES

CHAPTER/CAPITOLO

I GENERAL RULES

I.1 A small circle, open or filled in, representingthe hinge point, may be added to most of thesymbols. For example, see 07-02-02.

In some symbols the circle indicating the hingepoint shall be shown. For example, see 07-02-05.

I.2 For other methods of representing switches, es-pecially complex, electronic switches, see IEC617-12, section 17A and 29, and IEC 617-13,section 17.

SECTION/SEZIONE

1 QUALIFYNG SYMBOLS

N. Segno grafico Symbol Descrizione Description

07-01-01 Funzione di contattore Contactor function

07-01-02 Funzione di interruttore (di potenza)

Circuit breaker function

07-01-03 Funzione di sezionatore Disconnector (isolator) function

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 3 di 48

07-01-04 Funzione di interruttore di mano-vra-sezionatore

Switch-disconnector(isolating-switch) function

07-01-05 Funzione di apertura automaticaprovocata da un relè o sganciatoredi misura incorporati

Automatic tripping function initiat-ed by a built-in measuring relay orrelease

07-01-06 Funzione di contatto di posizione(fine corsa)1. Questo segno distintivo puòessere applicato per indicare uncontatto di posizione quando nonè necessario precisare il suomodo di operare. Nei casi in cuiquesto è necessario si dovrannousare i segni da 02-13-16 a02-13-19.

2. Questo segno è indicato su en-trambi i lati del segno del contattoquando il contatto è meccanica-mente comandato nelle due dire-zioni.

Position switch function

1. This qualifying symbol may beapplied to simple contact symbolsto indicate position switches if thereis no need to show the means ofoperating the contact. In complicat-ed cases, where it is desireable toshow the means of operation, oneof the symbols 02-13-16 through02-13-19 may be used instead.2. To depict a contact which ismechanically operated in both di-rections, this symbol shall beplaced on both sides of the con-tact symbol.

07-01-07 Funzione di ritorno automatico,per esempio ritorno a molla1. Questo segno può essere utiliz-zato per indicare una funzione diritorno automatico. Vedere, peresempio, 07-06-01.2. Questo segno non deve essereutilizzato con i segni da 07-01-01,a 07-01-04. In molti casi si può uti-lizzare il segno 02-12-07.

Automatic return function, for ex-ample, spring return1. This symbol may be used to in-dicate automatic return. For exam-ple, see 07-06-01.

2. This symbol shall not be usedtogether with qualifying symbols07-01-01, 07-01~2, 07-01-03 and07-01-04. In many cases, symbol02-12-07 may be used.

07-01-08 Funzione posizione mantenuta

1. Questo segno non è obbligato-rio per la rappresentazione dellafunzione sopra indicata. Quando ilsegno viene utilizzato occorre se-gnalare opportunamente la con-venzione fatta.2. Questo segno non deve essereusato con i segni da 07-01-01 a07-01-04. In molti casi si può uti-lizzare il segno grafico 02-12-08.

Non-automatic return (stay put)function1. This symbol may be used to in-dicate non-automatic return func-tion. When this convention is in-voked, its use should beappropriately referenced.

2. This symbol should not be usedtogether with qualifying symbols07-01-01, 07-01-02, 07-01-03 and07-01-04. In many cases, symbol02-12-08 may be used.

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03Pagina 4 di 48

CONTATTI

CONTATTI A DUE O TRE POSIZIONI

CHAPTER/CAPITOLO

II CONTACTS

SECTION/SEZIONE

2 CONTACTS WITH TWO OR THREE POSITIONS

07-01-09 Manovra positiva di un’apparec-chiatura1. Questo segno deve essere utiliz-zato per indicare che è assicuratao richiesta la manovra positiva diun’apparecchiatura meccanica nel-la direzione rappresentata. Questosignifica che la manovra assicurache tutti i contatti sono nella po-sizione corrispondente a quelladell’attuatore.2. Se i contatti rappresentati sonocollegati, il simbolo si deveapplicare a tutti i contatti collegati,salvo indicato diversamente(vedere segno grafico 07-08-07).

Positive operation of a switch

1. This symbol shall be used to in-dicate that the positive operationof a mechanical device in the di-rection shown is ensured or is re-quired. This means that the opera-tion ensures that all contacts are inthe position corresponding to theactivating device.

2. If contacts are shown linked,the symbol shall apply to all thelinked contacts unless otherwiseindicated (see symbol 07-08-07).

N. Segno grafico Symbol Descrizione Description

07-02-01 Contatto di chiusuraQuesto segno grafico è anche usa-to come segno generale di un in-terruttore inteso come dispositivomeccanico per chiudere e aprireun circuito.

Make contactThis symbol may also be used asthe general symbol for a switch.

07-02-02

07-02-03 Contatto di apertura Break contact

07-02-04 Contatto di scambio con interru-zione momentanea

Change-over break before makecontact

N. Segno grafico Symbol Descrizione Description

Forma 1Form 1

Forma 2Form 2

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 5 di 48

CONTATTI DI PASSAGGIO A DUE POSIZIONISECTION/SEZIONE

3 PASSING CONTACTS WITH TWO POSITIONS

07-02-05 Contatto di scambio con posizioned’apertura al centro.

Change-over contact with off-posi-tion in the centre

07-02-06 Contatto di scambio, senza inter-ruzione

Change-over make before breakcontact

07-02-07

07-02-08 Contatto a due chiusure Contact with two makes

07-02-09 Contatto a due aperture Contact with two breaks

N. Segno grafico Symbol Descrizione Description

07-03-01 Contatto di passaggio con chiusu-ra momentanea durante l’azione

Passing make contact closing mo-mentarily when its operating de-vice is actuated

07-03-02 Contatto di passaggio con chiusu-ra momentanea durante il rilascio

Passing make contact closing mo-mentarily when its operating de-vice is released

N. Segno grafico Symbol Descrizione Description

Forma 1Form 1

Forma 2Form 2

NORMA TECNICACEI EN 60617-7:1998-03Pagina 6 di 48

CONTATTI A FUNZIONAMENTO ANTICIPATO E RITARDATO

4 EARLY AND LATE OPERATING CONTACTS

SECTION/SEZIONE

07-03-03 Contatto di passaggio conchiusura momentanea durantel’azione e durante il rilascio

Passing make contact closingmomentarily when its operatingdevice is actuated or released

N. Segno grafico Symbol Descrizione Description

07-04-01 Contatto di chiusura anticipato(chiude in anticipo rispetto agli al-tri contatti di uno stesso gruppo)

Make contact (of a multiplecontact assembly) which is earlyto close relative to the other makecontacts of the assembly

07-04-02 Contatto di chiusura ritardato(chiude in ritardo rispetto agli altricontatti di uno stesso gruppo)

Make contact (of a multiplecontact assembly) which is late toclose relative to the other makecontacts of the assembly

07-04-03 Contatto di apertura ritardato(apre in ritardo rispetto agli altricontatti di uno stesso gruppo)

Break contact (of a multiplecontact assembly) which is late toopen relative to the other breakcontacts of the assembly

07-04-04 Contatto di apertura anticipato(apre in anticipo rispetto agli altricontatti di uno stesso gruppo)

Break contact (of a multiplecontact assembly) which is earlyto open relative to the other breakcontacts of the assembly

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 7 di 48

CONTATTI A RITARDO INTENZIONALE

Vedere i segni 02-12-05 e 02-12-06. La chiusurae l’apertura sono ritardate rispetto all’attiva-zione o alla disattivazione. Il movimento è ritar-dato nella direzione verso il centro dell’arco(“effetto paracadute”). Il segno di ritardo puòessere disegnato a lato del segno contatto piùadatto per l’applicazione e la designazione de-gli apparecchi.

SECTION/SEZIONE

5 CONTACTS WITH DELAYED OPERATION

5.1 See symbols 02-12-05 and 02-12-06. Closing andopening of the contact is delayed with respect tothe activation or deactivation operation. The move-ment is delayed in the direction towards the centreof the arc (“parachute effect”). The symbol for de-layed action may be drawn on that side of the con-tact symbol which is most suitable for the applica-tion and for the placing of item designations.

N. Segno grafico Symbol Descrizione Description

07-05-01 Contatto di chiusura, ritardato allachiusura

Make contact, delayed when thedevice containing the contact isbeing activated

07-05-02 Contatto di chiusura, ritardatoall’apertura

Make contact, delayed when thedevice containing the contact isbeing de-activated

07-05-03 Contatto di apertura, ritardato allachiusura

Break contact, delayed when thedevice containing the contact isbeing activated

07-05-04 Contatto di apertura, ritardatoall’apertura

Break contact, delayed when thedevice containing the contact Isbeing de-activated

07-05-05 Contatto di chiusura, ritardato siaall’apertura che alla chiusura.

Make contact, delayed both whenthe device containing the contactis being activated and when It isbeing de- activated

07-05-06 ESEMPIO:Insieme di contatti con un contattodi chiusura non ritardato, uncontatto di chiusura ritardatoall’apertura ed un contatto diapertura ritardato all’apertura.

EXAMPLE: Contact assembly with one make contact not delayed, one make contact delayed when the device containing the contact is being activated and one break contact delayed when the device containing the contact is being de-activated

NORMA TECNICACEI EN 60617-7:1998-03Pagina 8 di 48

CONTATTI A RITORNO AUTOMATICO ED A POSIZIONE MANTENUTA

Si applicano le regole dei segni 07-01-07 e07-01-08.

AUSILIARI DI COMANDO, APPARECCHI DI MANOVRA E AVVIATORI

Poiché gli apparecchi manovrati con pulsante otirante sono in generale a ritorno automatico, nonè necessario completare il relativo segno graficocon quello del ritorno automatico (02-12-07).D’altra parte è necessario invece rappresentare ilsegno di posizione mantenuta (02-12-08) negliapparecchi che presentano questa caratteristica.

Gli apparecchi comandati a rotazione sono, ingenerale, senza ritorno automatico. Non èdunque necessario completare il relativo segnografico con quello della posizione mantenuta(02-12-08). D’altra parte è necessario invece usare

6 AUTOMATIC RETURN AND NON-AUTOMATIC

SECTION/SEZIONE

RETURN CONTACTS

6.1 The rules with symbols 07-01-07 and 07-01-08apply.

III SWITCHES, SWITCHGEAR AND STARTERS

CHAPTER/CAPITOLO

III.1 Devices with “push” or “pull” operation mostoften have automatic return. It is therefore notnecessary to show the automatic return symbol(02-12-07). On the other hand, a detent symbol(02-12-08) shell be shown in those cases wherenon-return exists.

III.2 Devices operated by turning do not usuallyhave automatic return. It is therefore notnecessary for the detent symbol (02-12-08)to be shown. On the other hand, the auto-matic return symbol (02-12~7) should be

N. Segno grafico Symbol Descrizione Description

07-06-01 Contatto di chiusura a ritorno au-tomatico

Make contact with automatic re-turn

07-06-02 Contatto di chiusura a posizionemantenuta

Make contact without automaticreturn Stay put make contact

07-06-03 Contatto di apertura a ritorno au-tomatico

Break contact with automatic re-turn

07-06-04 Contatto a due vie e tre posizionicon posizione centrale diinterruzione, a ritorno automaticoper la posizione di sinistra ed aposizione mantenuta per laposizione di destra

Two-way contact with off-positionin the centre and automatic returnfrom one position (shown to theleft), and without automatic returnin the opposite position

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 9 di 48

il segno del ritorno automatico (02-12-07) nei casiappropriati.

AUSILIARI DI COMANDO UNIPOLARI

shown in those cases where an automatic re-turn exists.

SECTION/SEZIONE

7 SINGLE-POLE SWITCHES

N. Segno grafico Symbol Descrizione Description

07-07-01 Contatto di chiusura con comandomanuale, segno generale

Manually operated switch, gener-al symbol

07-07-02 Contatto di chiusura, con coman-do a pulsante ed a ritorno auto-matico

Push-button switch make contactand automatic return

07-07-03 Contatto di chiusura, con comandoa tirante ed a ritorno automatico

Pull-switch with make contact andautomatic return

07-07-04 Contatto di chiusura, con comandorotativo, senza ritorno automatico

Turn-switch with make contactwithout automatic return

07-07-05 Contatto di chiusura con comandoa pulsante a manovra positiva dichiusura (per esempio: allarme)

Push-button switch with positiveoperation of the make contact (forexample: alarm)

07-07-06 Contatto di apertura con comandodi arresto di emergenza (azionatoda un pulsante con “testa afungo”) e, a posizione mantenuta,a manovra positiva di apertura

Emergency stop switch(“mushroom-head” activated)with positive opening operation ofthe break contact and maintainposition

NORMA TECNICACEI EN 60617-7:1998-03Pagina 10 di 48

AUSILIARI DI POSIZIONE

Se, in un gruppo di contatti, uno o più di questicontatti è costruito per avere una manovra positi-va, la positività può riguardare

n o l’apertura del contatto(i) di apertura (peresempio 07-08-04: Comando di posizione e07-07-06: Comando di arresto di emergenza)o la chiusura del contatto di chiusura (peresempio 07-07-05: Allarme) e

n o tutti i contatti o solamente dei contatti parti-colari (vedere per esempio 07-13-14) ma

n non l’apertura e la chiusura di uno stesso con-tatto contemporaneamente.

SECTION/SEZIONE

8 POSITION SWITCHES

Where in a set of contacts one or some of themare constructed to have positive opening opera-tion this positivity may concern:

n either the opening of break contact(s) (forexample 07-08-04: Position switch and07-07-06: Emergency stop switch) or theclosing of a make contact (for example07-07-05: Alarm) and

n either all the contacts or only particular con-tacts (see for example 07-1314) but

n not both the opening and the closing of thesame contact.

N. Segno grafico Symbol Descrizione Description

07-08-01 Contatto di posizione di chiusura(fine corsa)

Position switch, make contact

07-08-02 Contatto di posizione di apertura(fine corsa)

Position switch, break contact

07-08-03 Contatto di posizione (fine corsa)a due circuiti separati, azionatomeccanicamente nei due sensi

Position switch, mechanically op-erated in both directions with twoseparate circuits

07-08-04 Contatto di posizione con contattodi apertura a manovra positiva diapertura

Position switch with positiveopening operation of the breakcontact

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 11 di 48

CONTATTI FUNZIONANTI PER EFFETTO DELLA TEMPERATURA

CONTATTI FUNZIONANTI PER EFFETTO DELLE VARIAZIONI DI VELOCITÀ E CONTATTI IN AMPOLLA DI MERCURIO

Trasferita nell’appendice A1.

9 TEMPERATURE SENSITIVE SWITCH

SECTION/SEZIONE

10 SPEED CHANGE SENSITIVE CONTACTS, MERCURY AND LEVELLING SWITCHES

SECTION/SEZIONE

Transferred to annex A1.

N. Segno grafico Symbol Descrizione Description

07-09-01 Contatto di chiusura, sensibile allatemperaturaIl simbolo può essere sostituitodal valore della temperatura di fun-zionamento

Temperature sensitive switch,make contact

may be replaced by the operat-ing temperature conditions

07-09-02 Contatto di apertura, sensibile allatemperaturaVedere nota al segno 07-09-01

Temperature sensitive switch,break contactThe note with symbol 07-09-01applies

07-09-03 Contatto di apertura, funzionanteper effetto termico diretto (es. bi-metallo)È importante distinguere tra uncontatto come quello raffigurato eun contatto di relè termico, chepuò essere rappresentato comesegue:

Self-operating thermal switch(for example, bimetal) break con-tactIt is important to distinguish be-tween a contact as shown and acontact of a thermal relay, whichin detached representation may beshown as follows:

07-09-04 Tubo a scarica nel gas conbimetallo (starter per lampadafluorescente)

Gas discharge tube with thermalelement Starter for fluorescentlamp

Q Q

NORMA TECNICACEI EN 60617-7:1998-03Pagina 12 di 48

ESEMPI DI COMMUTATORI A PIÙ POSIZIONI INCLUSO L’ATTUATORE DI CONTROLLO

Vedere III.1, nella sezione 7.

Vedere III.2, nella sezione 7

11 EXAMPLES OF MULTI-POSITION SWITCHES,

SECTION/SEZIONE

INCLUDING CONTROL SWITCHES

11.1 See III.1 in section 7.

11.2 See III.2 In section 7.

N. Segno grafico Symbol Descrizione Description

07-11-01 Commutatore con comando a le-va, a tre posizioni, con posizionesuperiore mantenuta e con ritornoautomatico dalla posizione infe-riore alla posizione centrale, rap-presentato con i suoi terminali

Lever-operated switch, three posi-tions, locking in the upper posi-tion and with automatic returnfrom the lower position to themiddle one, shown with terminals

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 13 di 48

07-11-02 Commutatore con comando a pul-santeUn gruppo di contatti è comanda-to spingendo l’attuatore (con ritor-no automatico) e un altro gruppoè comandato ruotando l’attuatore(senza ritorno automatico), rap-presentato con i suoi terminali.La graffa indica che si tratta di ununico organo di comando.

Button-operated switch

One set of contacts is operated bypushing the button (automatic re-turn) and another set by turning it(non-automatic return), shownwith terminals.

The bracket indicates that there isonly one actuator.

07-11-03 Commutatore con comando a pul-santeLo stesso gruppo di contatti puòessere azionato o spingendo l’at-tuatore ( con ritorno automatico)o ruotando l’attuatore (senza ritor-no automatico), rappresentato coni suoi terminali

Button-operated switch

The same set of contacts may beoperated in two different ways, ei-ther by turning (with non-auto-matic return) or pushing (with au-tomatic return), shown withterminals.

07-11-04 Commutatore unipolare a n posi-zioni (in figura n = 6)

Multi-position switch (six posi-tions shown)

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03Pagina 14 di 48

07-11-05 Commutatore unipolare a n posi-zioniVariante per n piccolo (in figuran = 4)

Multi-position switch

To be used with a small numberof positions (4 positions shown).

07-11-06 Esempio con diagramma di posi-zioneÈ utile qualche volta indicare lafunzione di ciascuna posizione delcommutatore, completando, conun testo, il diagramma di posi-zione. È anche possibile indicare ilimiti imposti meccanicamente aldispositivo di comando come indi-cato negli esempi che seguono:

Example with position diagram

It is sometimes convenient to in-dicate the purpose of eachswitch position by adding text tothe position diagram. It is alsopossible to indicate limitations ofmovement of the operating de-vice as in the examples whichfollow:

Il dispositivo di comando(per esempio un manipo-latore rotativo) può essereruotato solo fra le posizio-ni 1 e 4 nei due sensi

Il dispositivo di comandopuò ruotare solo nel sen-so orario

Il dispositivo di comandopuò essere ruotato inqualsiasi posizione insenso orario ma può es-sere ruotato in senso an-tiorario solo fra le posi-zioni 3 e 1

The operating device(for example hand-wheel) can be turnedonly from positions 1 to4 and back

The operating devicecan be turned in theclockwise direction only

The operating devicecan be turned in theclockwise direction with-out limitation and maybe turned in thecounter-clockwise direc-tion only between posi-tions 3 and 1

07-11-07 Commutatore a 4 posizioni, per 4circuiti indipendenti, a comandomanuale

Four-position switch, manuallyoperated, with four independentcircuits

07-11-08 Commutatore unipolare a 4 posi-zioni, in cui la posizione 2 nonpuò essere connessa

Single-pole, four-position switchThe second position cannot beconnected.

07-11-09 Commutatore unipolare a 6 posi-zioni con contatto mantenuto nelpassaggio da una posizione allasuccessiva

Single-pole six-position switchA wiper bridges only while pass-ing from one position to another.

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 15 di 48

SEGNI GRAFICI A BLOCCO PER COMMUTATORI COMPLESSI

Ci sono numerosi modi per realizzare meccanica-mente funzioni di commutazione complesse, peresempio commutatori rotativi a pacco, commuta-tori a cursore, combinatori di contatti azionate dacamme, ecc. Ci sono anche numerosi modi perrappresentare le funzioni di commutazione suglischemi dei circuiti (vedere Pubblicazione IEC1082-2). Lo studio ha mostrato che non c’è ununico sistema di rappresentazione che sia supe-riore agli altri in tutti i casi d’applicazione. Ilmetodo impiegato dovrà essere scelto secondol’uso dello schema e il grado di complessità delcommutatore che si desidera simboleggiare.

La presente Norma propone un metodo possibiledi simbolizzazione dei commutatori complessi.Per facilitare la comprensione ciascun esempiocontiene un disegno costruttivo schematicodell’apparecchio simboleggiato. Il sistema se-guente utilizza un segno generale per un commu-

12 BLOCK SYMBOLS FOR COMPLEX SWITCHES

SECTION/SEZIONE

12.1 There are many ways in which complex switch-ing functions can be achieved mechanically, forexample by rotary wafer switches, slide switch-es, drum controllers, cam-operated contact as-semblies, etc. There are also many ways inwhich the switching functions may be symbol-ized on circuit diagrams (see IEC 1082-2). Stud-ies have shown that there is no unique systemof symbolization which is superior in every ap-plication. The system employed should be cho-sen with due regard to the purpose of the dia-gram and the degree of complexity of theswitching device that it is desired to symbolize.

Therefore this section presents only one ofthe possible methods for symbolizing com-plex switches. To facilitate understanding,each example includes a constructional draw-ing of the device symbolized. The methodshown here uses a general symbol for a com-

07-11-10 Commutatore unipolare a più po-sizioni con contatto mantenuto sutre contatti consecutivi in ciascunaposizione

Single-pole multi-position switchA wiper bridges three consecutiveterminals in each switch position.

07-11-11 Commutatore unipolare a più po-sizioni con contatto mantenuto sutre contatti contemporaneamente,escludendone uno intermedio, inciascuna delle posizioni

Multi-position switchA wiper bridges three non-conse-cutive terminals in each position,but omits one intermediate termi-nal in each switch position.

07-11-12 Commutatore unipolare a più po-sizioni per la messa in parallelo aeffetto cumulativo

Single-pole multi-position switchfor cumulative parallel switching

07-11-13 Elemento di un commutatoremultipolare a 6 posizioni. Nell’elemento rappresentato, nelpassaggio dalla posizione 2 allaposizione 3 la chiusura vieneanticipata rispetto a quella deglialtri elementi mentre nel passaggiodalla posizione 5 alla posizione 6l’apertura viene ritardata. Quandola parte mobile scorre nell’altrosenso la chiusura anticipatadiventa un’apertura ritardata eviceversa.

One polo of a six-position multi-poleswitchThe pole shown makes earlierthan the other poles when thewiper moves from position 2 to 3and breaks later than the otherpoles when the wiper moves fromposition 5 to 6. When the wipermoves in the opposite directionthe early make becomes a latebreak and the late break becomesan early make.

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03Pagina 16 di 48

tatore complesso che deve essere completato dal-la tabella delle connessioni. Sono rappresentatidue esempi.

plex switch which must be supplemented bya table of connections. Two examples areshown.

N. Segno grafico Symbol Descrizione Description

07-12-01 Commutatore complesso, segnogenerale

Complex switch, general symbol

07-12-02 ESEMPI:Commutatore rotativo a pacco, a18 posizioni e 6 terminali, qui in-dividuati da A a F, realizzato comesotto indicato (commutatore rap-presentato in posizione 1)Le lettere illustrate non fannoparte del segno

EXAMPLES:18-position rotary wafer switchwith six terminals, here designatedA to F, constructed as shown be-low (switch shown in position 1)The letters shown are not part ofthe symbol.

PosizionePosition

InterconnessioniInterconnection of terminals

A B C D E

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

Tabella delle connessioniTable of connections

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 17 di 48

APPARECCHI DI MANOVRA E DI COMANDOSECTION/SEZIONE

13 POWER SWITCHING DEVICES

07-12-03 Commutatore rotativo a tamburo a6 posizioni e a 5 terminali realiz-zato come sotto indicato:

Six-position rotary drum switchwith 5 terminals, constructed asshown below:

PosizionePosition

InterconnessioniInterconnection of terminals

A B C D E

1

2

3

4

5

6

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+ –

I simboli + – ❍ indicano i terminaliche sono rispettivamente connessitra di loro in una data posizione(posizione di riposo o posizioneintermedia) dell’organo di coman-do del commutatore; ad esempio iterminali che hanno lo stesso sim-bolo, es. + sono interconnessi.Nel caso siano necessari altri sim-boli si utilizzeranno i caratteri di-sponibili di una macchina da scri-vere ad esempio x, =.Le lettere rappresentate non fannoparte del simbolo.

The symbols (+ – ❍) in the tableindicate the terminals that are con-nected together at any position(rest- position or intermediate po-sition) of the switch, i.e. terminalshaving the same indicating sym-bols, for example +, are intercon-nected.Where additional symbols are re-quired, the characters available ona typewriter should be used, forexample x, =.The letters shown are not part ofthe symbol.

N. Segno grafico Symbol Descrizione Description

07-13-01 Usare il segno 07-02-01 o 07-02-02Use symbol 07-02-01 or 07-02-02

Interruttore (segno generico perogni dispositivo meccanico che at-tua la chiusura o apertura di uncircuito)

Switch

07-13-02 Contattore Contatto di chiusura principale (contatto aperto in condizione di riposo)

ContactorMain make contact of a contactor(Contact opened in the unoperat-ed position)

07-13-03 Contattore ad apertura automatica,determinata da un relè o sgancia-tore di misura incorporato

Contactor with automatic trippinginitiated by a built-in measuringrelay or release

N. Segno grafico Symbol Descrizione Description

Tabella delle connessioniTable of connections

NORMA TECNICACEI EN 60617-7:1998-03Pagina 18 di 48

07-13-04 ContattoreContatto di apertura principale (contatto chiuso in condizione di riposo)

ContactorMain break contact of a contactor(contact closed in the unoperatedposition)

07-13-05 Interruttore (di potenza) Circuit breaker

07-13-06 Sezionatore Disconnector (isolator)

07-13-07 Sezionatore a due vie e tre posi-zioni con posizione centrale diapertura

Two-way disconnector (Isolator)with off-position in the centre

07-13-08 Interruttore di manovra-seziona-tore

Switch-disconnector (on-load iso-lating switch)

07-13-09 Interruttore di manovra-seziona-tore ad apertura automatica, deter-minata da un relè o sganciatore dimisura incorporato

Switch-disconnector with automat-ic tripping initiated by a built-inmeasuring relay or release

07-13-10 Sezionatore a comando manuale,con dispositivo di blocco

Disconnector (isolator) with block-ing device, manually operated

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 19 di 48

07-13-11 Meccanismo ad apertura liberaLe linee tratteggiate che rappre-sentano le diverse parti del siste-ma di collegamento devono esseredisposte nel modo seguente:

* Dal dispositivo di comando confunzione di apertura; sono rappre-sentati due luoghi a scelta.

Trip-free mechanismDashed lines representing the var-ious parts of the linkage systemshall be located in the followingway:

* From actuator having an overrid-ing opening function; two alterna-tive locations shown.

07-13-12 ESEMPIO:Apparecchio meccanico di inter-ruzione, tripolare, motorizzato omanuale, con meccanismo adapertura libera e:n sganciatore termico di sovrac-

caricon sganciatore di massima cor-

renten attuatore manuale con disposi-

tivo di mantenimenton bobina di apertura remotan un contatto ausiliario di chiusu-

ra ed uno di apertura

EXAMPLE: Three-pole mechanical switchingdevice, operated by motor ormanually, with trip-free mecha-nism, and: n thermal overload release

n overcurrent release

n hand release with detent

n coil for remote release n one make and one break auxil-

iary contact

07-13-13 Apparecchio meccanico di interru-zione, tripolare, motorizzato concomando a molla precaricato e:n tre sganciatori di sovraccaricon tre sganciatori di massima cor-

renten attuatore manualen bobina di apertura remotan tre contatti di chiusura princi-

palin un contatto ausiliario di chiusu-

ra e uno di aperturan un contatto di posizione per

avviare ed arrestare il funziona-mento del motore

Three-pole mechanical switchingdevice operated by motor with aspring storage and:n three overload releases n three overcurrent releases

n hand release n coil for remote releasen three main make contacts

n one make and one break auxil-iary contact

n one position switch to start andstop the operation of the motor

07-13-14 Interruttore di sicurezza, con trecontatti principali di apertura amanovra positiva e un contattoausiliario di chiusura senzamanovra positiva

Switch with positive openingoperation of the three main breakcontacts and the auxiliary makecontact without positive operation

N. Segno grafico Symbol Descrizione Description

Dal dispositivodi comandodi chiusuraed apertura

Versoi contattiprincipali

ed ausiliari

From theoperatingmeans foropening andclosing

To associatedmain andauxiliarycontacts

NORMA TECNICACEI EN 60617-7:1998-03Pagina 20 di 48

SEGNI GRAFICI A BLOCCO PER AVVIATORI DI MOTORI

14 BLOCK SYMBOLS FOR MOTOR STARTERS

SECTION/SEZIONE

N. Segno grafico Symbol Descrizione Description

07-14-01 Avviatore per motore, segno ge-neralePer indicare tipi particolari di av-viatori, si possono riportare sim-boli distintivi all’interno del segnogenerale. Vedere i segni 07-14-05,07-14-07 e 07-14-08.

Motor starter, general symbolQualifying symbols may be showninside the general symbol to indi-cate particular types of starters.See symbols 07-14-05, 07-14-07and 07-14-08.

07-14-02 Avviatore a gradiniSi può indicare anche il numero digradini

Starter operating in stepsThe number of steps may be indi-cated.

07-14-03 Avviatore-regolatore Starter-regulator

07-14-04 cancellatodeleted

Trasferito all’Appendice A: 07-A2-01 Transferred to Annex A: 07-A2-01

07-14-05 Avviatore diretto mediante contat-tore (a piena tensione) per duesensi di marcia

Direct-on-line starter with contac-tor for reversing the rotation of amotor

07-14-06 Avviatore stella-triangolo Star-delta starter

07-14-07 Avviatore mediante autotrasforma-tore

Starter with auto-transformer

07-14-08 Avviatore-regolatore a tiristori Starter-regulator with thyristors

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 21 di 48

RELÈ ELETTROMECCANICI A TUTTO O NIENTE

DISPOSITIVI DI COMANDO

CHAPTER/CAPITOLO

IV ALL-OR-NOTHING RELAYS

SECTION/SEZIONE

15 OPERATING DEVICES

N. Segno grafico Symbol Descrizione Description

07-15-01 Dispositivo di comando, segnogeneraleBobina di comando, segno ge-neraleSe una bobina di comando ha piùavvolgimenti separati, questi pos-sono essere indicati da un numerocorrispondente di tratti obliqui odalla ripetizione dei simboli (ve-dere 07-15-04).

Operating device, general symbol

Relay coil, general symbol

Operating devices with severalwindings may be indicated by in-clusion inside the outline of theappropriate number of inclinedstrokes (see 07-15-04).

07-15-02 ESEMPI:Bobina di comando con due av-volgimenti separati, rappresenta-zione raggruppata

EXAMPLES:Operating device with two sepa-rate windings, attached represen-tation

07-15-03

07-15-04

07-15-05 Bobina di comando con due av-volgimenti separati, rappresenta-zione separata

Operating device with two sepa-rate windings, detached represen-tation

07-15-06

07-15-07 Bobina di comando di un relè conritardo alla ricaduta

Relay coil of a slow-releasing relay

Forma 1Form 1

Forma 2Form 2

Forma 1Form 1

Forma 2Form 2

Forma 1Form 1

Forma 2Form 2

NORMA TECNICACEI EN 60617-7:1998-03Pagina 22 di 48

07-15-08 Bobina di comando di un relè conritardo all’attrazione

Relay coil of a slow-operating re-lay

07-15-09 Bobina di comando di un relè conritardo alla ricaduta e all’attrazione

Relay coil of a slow-operating andslow-releasing relay

07-15-10 Bobina di comando di un relèrapido (attrazione e ricadutarapide)

Relay coil of a high speed relay(fast-operating and fast-releasing)

07-15-11 Bobina di comando di un relè in-sensibile alla corrente alternata

Relay coil of a relay unaffected byalternating current

07-15-12 Bobina di comando di un relè acorrente alternata

Relay coil of an alternating currentrelay

07-15-13 Bobina di comando di un relè arisonanza meccanica

Relay coil of a mechanically reso-nant relay

07-15-14 Bobina di comando di un relè adaggancio meccanico

Relay coil of a mechanicallylatched relay

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 23 di 48

07-15-15 Bobina di comando di un relè po-larizzatoPossono essere usati punti (•) perindicare la relazione tra la direzio-ne della corrente circolantenell’avvolgimento di un relè pola-rizzato e il movimento dell’ele-mento di contatto secondo la con-venzione che segue.Quando un morsetto dell’avvolgi-mento identificato dal punto dipolarità è positivo rispetto all’altromorsetto dell’avvolgimento, l’ele-mento di contatto si sposta o ten-de a spostarsi verso la posizionesegnata con il punto.

Relay coil of a polarized relay

Polarity dots (•) may be used toindicate the relationship betweenthe direction of the currentthrough the winding of a polar-ized relay and the movement ofthe contact arm according to thefollowing connection.When the winding terminal identi-fied by the polarity dot is positivewith respect to the other windingterminal, the contact arm movesor tends to move towards the po-sition marked with the dot.

07-15-16 ESEMPI:Relè polarizzato che funziona peruna sola direzione di correntenell’avvolgimento e che ritorna inposizione di riposo dopo l’inter-ruzione della corrente di coman-do.

EXAMPLES:Polarized relay, self restoring, op-erating for only one direction ofcurrent in the winding

07-15-17 Relè polarizzato, con posizionemediana, che funziona per i duesensi della corrente nell’avvolgi-mento e ritorna nella posizionemediana dopo l’interruzione dellacorrente di comando.

Polarized relay with neutral posi-tion, self restoring, operating foreither direction of current in thewinding

07-15-18 Relè polarizzato a due posizionistabili

Polarized relay with two stablepositions

07-15-19 Bobina di comando di un relè arimanenza

Relay coil of a remanent relay

07-15-20

07-15-21 Dispositivo di comando di un relètermico

Operating device of a thermal re-lay

N. Segno grafico Symbol Descrizione Description

Forma 1Form 1

Forma 2Form 2

NORMA TECNICACEI EN 60617-7:1998-03Pagina 24 di 48

RELÈ DI MISURA E DISPOSITIVI SIMILARI

SEGNI GRAFICI A BLOCCO E SEGNI GRAFICI DISTINTIVI

CHAPTER/CAPITOLO

V MEASURING RELAYS AND RELATED DEVICES

16 BLOCK SYMBOL AND QUALIFYING SYMBOLS

SECTION/SEZIONE

07-15-22 Dispositivo di comando di un relèelettronico

Operating device of an electronicrelay

N. Segno grafico Symbol Descrizione Description

07-16-01 Relè di misuraDispositivo similare1. L’asterisco deve essere sostituitoda una o più lettere, oppure dauno o più segni distintivi indicantile caratteristiche del dispositivocollocati nell’ordine seguente:n grandezza caratteristica e suo

modo di variazione;n senso di trasmissione dell’energia;n campo di aggiustaggio;n rapporto di ripristino;n azione ritardata;n valore del ritardo.2. I simboli letterali delle grandez-ze caratteristiche debbono esserein accordo con le norme esistenti,per esempio IEC 27 e ISO 31.3. Nel segno grafico può essere in-clusa una cifra indicante il numerodi elementi di misura simili - Ve-dere segno 07-17-05.4. Il segno grafico può essere usa-to o come segno a blocco che rap-presenta l’insieme di un dispositi-vo, o come segno del solo organodi comando di un dispositivo.

Measuring relayDevice related to a measuring relay1. The asterisk shall be replacedby one or more letters or qualify-ing symbols indicating the param-eters of the device, in the follow-ing order:n characteristic quantity and its

mode of variation;n direction of energy flow;n setting range;n re-setting ratio;n delayed action;n value of time delay.2. Letter symbols for characteristicquantities shall be in accordance -with established standards, for ex-ample, IEC 27 and ISO 31. 3. A figure giving the number ofsimilar measuring elements maybe included in the symbol asshown in example 07-17-05.4. The symbol may be used as afunctional symbol representing thewhole of the device, or as a sym-bol representing only the actuat-ing element of the device.

07-16-02 Tensione di guasto a massa Voltage failure to frame(frame potential in case of fault)

07-16-03 Tensione residua Residual voltage

07-16-04 Corrente di ritorno Reverse current

07-16-05 Corrente differenziale Differential current

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 25 di 48

ESEMPI DI RELÈ DI MISURASECTION/SEZIONE

17 EXAMPLES OF MEASURING RELAYS

07-16-06 Corrente differenziale (valore rela-tivo)

Percentage differential current

07-16-07 Corrente di guasto a terra Earth fault current

07-16-08 Corrente nel neutro Current in the neutral conductor

07-16-09 Corrente fra i punti neutri di duesistemi polifasi

Current between neutrals of twopolyphase systems

07-16-10 Potenza all’angolo di fase a Power at phase angle a

07-16-11 Caratteristica di ritardo a tempoinverso

Inverse time-lag characteristic

N. Segno grafico Symbol Descrizione Description

07-17-01 Relè a mancanza di tensione No voltage relay

07-17-02 Relè a corrente di ritorno Reverse current relay

07-17-03 Relè di minima potenza attiva Underpower relay

07-17-04 Relè di massima corrente adazione ritardata

Delayed overcurrent relay

07-17-05 Relè di massima corrente con dueelementi di corrente, con campodi aggiustaggio da 5 A a 10 A

Overcurrent relay with two mea-suring elements and a settingrange from 5 A to 10 A

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03Pagina 26 di 48

07-17-06 Relè di massima potenza reattiva:n trasmissione dell’energia verso

le sbarren aggiustaggio per 1 Mvarn ritardo aggiustabile tra 5 s e

10 s

Overpower relay for reactive power:n energy-flow towards the bus-

barsn operating value 1 Mvar n time-lag adjustable from 5 s to

10 s

07-17-07 Relè di minima tensione:n campo di aggiustaggio da 50 V

a 80 Vn rapporto di ripristino 130%

Undervoltage relay:n setting range from 50 V to 80 V

n resetting ratio 130%

07-17-08 Relè di massima e minima cor-rente.n aggiustaggio superiore: 5 An aggiustaggio inferiore: 3 A

Current relay with maximum andminimum settings, shown withlimits 3 A and 5 A.

07-17-09 Relè di minima impedenza Under-impedance relay

07-17-10 Relè rilevatore di corto circuito traspire

Relay detecting short-circuits be-tween windings

07-17-11 Relè rilevatore dell’interruzione diavvolgimento

Divided-conductor detection relay

07-17-12 Relè rilevatore della mancanza difase in un sistema trifase

Phase-failure detection relay in athree-phase system

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 27 di 48

DISPOSITIVI VARISECTION/SEZIONE

18 OTHER DEVICES

07-17-13 Relè rilevatore di bloccaggio delrotore mediante misura di corrente

Locked-rotor detection relay oper-ating by current measuring

07-17-14 Relè di massima corrente a dueuscite, una attivata quando lacorrente supera cinque volte ilvalore di aggiustaggio, l’altra concaratteristica di ritardo a tempoinverso

Overcurrent relay with twooutputs, one is active when thecurrent is above five times thesetting value, the other is activedepending on the inverse time-lagcharacteristic setting of the device

N. Segno grafico Symbol Descrizione Description

07-18-01 Relè Buchholz (a sviluppo di gas) Buchholz protective device (gasrelay)

07-18-02 Dispositivo di richiusuraautomatica

Device for auto-reclosingAuto-reclose relay

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03Pagina 28 di 48

DISPOSITIVI SENSIBILI ALLA PROSSIMITÀ O AL TOCCO

SENSORI

DISPOSITIVI DI CONTATTO

VI PROXIMITY AND TOUCH-SENSITIVE DEVICES

CHAPTER/CAPITOLO

SECTION/SEZIONE

19 SENSORS AND DETECTORS

SECTION/SEZIONE

20 SWITCHES

N. Segno grafico Symbol Descrizione Description

07-19-01 Sensore di prossimità Proximity sensor

07-19-02 Dispositivo sensibile alla prossimi-tà, segno a bloccoSi può indicare il principio di fun-zionamento

Proximity sensing device, blocksymbolThe method of operating may beindicated.

07-19-03 ESEMPIO:Dispositivo di prossimità capaciti-vo che funziona all’avvicinamentodi materiale solido

EXAMPLE:Capacitive proximity detector op-erating on the approach of solidmaterial

07-19-04 Sensore al tocco Touch sensor

N. Segno grafico Symbol Descrizione Description

07-20-01 Dispositivo sensibile al tocco, concontatto di chiusura

Touch sensitive switch, make con-tact

07-20-02 Dispositivo sensibile alla prossi-mità, con contatto di chiusura

Proximity switch, make contact

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 29 di 48

DISPOSITIVI DI PROTEZIONE

FUSIBILI ED INTERRUTTORI CON FUSIBILI

CHAPTER/CAPITOLO

VII PROTECTIVE DEVICES

SECTION/SEZIONE

21 FUSES AND FUSE-SWITCHES

07-20-03 Dispositivo sensibile alla prossi-mità, comandato dall’avvicinamen-to di un magnete, con contatto dichiusura

Proximity switch, operated on theapproach of a magnet, make con-tact

07-20-04 Dispositivo sensibile alla prossimità,comandato dall’avvicinamento diferro, con contatto di apertura

Proximity switch, operated on theapproach of iron, break contact

N. Segno grafico Symbol Descrizione Description

07-21-01 Fusibile (segno generale) Fuse, general symbol

07-21-02 Fusibile con indicazione, mediantetratto con spessore maggiore,dell’estremo che rimane sotto ten-sione

Fuse with the side, that remainslive after blowing, indicated by athick line

07-21-03 Fusibile con percussore Fuse with mechanical linkage(striker fuse)

07-21-04 Fusibile con percussore e con cir-cuito di segnalazione, a tre mor-setti

Fuse with alarm contact, three ter-minals

07-21-05 Fusibile con percussore e con cir-cuito di segnalazione separato

Fuse with separate alarm circuit

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03Pagina 30 di 48

SPINTEROMETRI E SCARICATORISECTION/SEZIONE

22 SPARK GAPS AND ARRESTERS

07-21-06 Interruttore di manovra tripolarecon apertura automatica comanda-ta da uno qualunque dei fusibilicon percussore

Three-pole switch with automaticrelease by any one of the strikerfuses

07-21-07 Interruttore di manovra con fu-sibile incorporato (segno gene-rale)

Fuse-switch

07-21-08 Sezionatore con fusibile incorpo-rato

Fuse-disconnector (fuse isolator)

07-21-09 Interruttore di manovra-sezionatore,con fusibile incorporato

Fuse switch-disconnector (on-loadisolating fuse switch)

N. Segno grafico Symbol Descrizione Description

07-22-01 Spinterometro Spark gap

07-22-02 Spinterometro doppio Double spark gap

07-22-03 Scaricatore Surge diverterLightning arrester

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 31 di 48

ESTINTORI

Trasferita nell’Appendice A.3

SEGNI GRAFICI DIVERSI

BOBINE D’ACCENSIONE E INDICATORI A CARTELLINO

Trasferita nell’Appendice A4

INTERRUTTORI STATICI

SECTION/SEZIONE

23 FIRE-EXTINGUISHERS

Transferred to 3 of annex A

CHAPTER/CAPITOLO

VIII MISCELLANEOUS SYMBOLS

24 IGNITERS AND FLAG-INDICATORS

SECTION/SEZIONE

Transferred to annex A4

SECTION/SEZIONE

25 STATIC SWITCHES

07-22-04 Limitatore di tensione nel gas Protective gas discharge tube

07-22-05 Limitatore di tensione nel gas,simmetrico

Symmetric protective gas dischargetube

N. Segno grafico Symbol Descrizione Description

07-25-01 Interruttore statico, segno generale1. Il cerchio piccolo che rappre-senta il cardine (vedere capitolo I,nota generale I.2) non deve essereaggiunto a questo segno.2. Possono essere aggiunti segnigrafici distintivi per precisare lafunzione dell’interruttore statico, inconformità con le sezioni da 2 a 5.

Static switch, general symbol1. The small circle representingthe hinge point (see chapter 1,general rule 1.2) shall not be add-ed to this symbol.2. Appropriate qualifying symbolsmay be added to denote the func-tion of the static switch, accordingto sections 2 to 5.

07-25-02 Contattore statico (semicondut-tore)

Static (semiconductor) contactor

07-25-03 Interruttore statico, passaggiodella corrente in una soladirezione

Static switch, passing current inone direction only

N. Segno grafico Symbol Descrizione Description

NORMA TECNICACEI EN 60617-7:1998-03Pagina 32 di 48

DISPOSITIVI STATICI DI CONNESSIONE

ACCOPPIATORI E RELÈ STATICI, SEGNI GRAFICI A BLOCCO

SECTION/SEZIONE

26 STATIC SWITCHING DEVICES

27 COUPLING DEVICES AND STATIC RELAYS,

SECTION/SEZIONE

BLOCK SYMBOLS

N. Segno grafico Symbol Descrizione Description

07-26-01 Relè statico, segno generale rap-presentato con contatto di chiusu-ra a semiconduttore.Può essere aggiunto un segnografico distintivo per precisare iltipo di elemento di comando

Static relay, general symbol,shown with semiconductor makecontactA qualifying symbol to denote thetype of actuating element may beadded.

07-26-02 ESEMPIO:Relè statico comandato da diodoad emissione luminosa e rappre-sentato con contatto di chiusura asemiconduttore.

EXAMPLE:Static relay with light emitting di-ode as actuator shown with makecontact semiconductor

07-26-03 ESEMPIO:Relè termico di sovraccarico, tri-fase, con due contatti a semicondut-tore, di cui un contatto di chiusura asemiconduttore e un contatto diapertura a semiconduttore; l’attua-tore necessita di un’alimentazioneausiliaria separata.

EXAMPLE:Three-pole thermal overload re-lay with two semiconductor con-tacts one semiconductor makecontact and one semiconductorbreak contact; the actuator needsa separate auxiliary power supply.

07-26-04 ESEMPIO:Dispositivo di comando semicon-duttore con contatto di chiusura asemiconduttore

EXAMPLE:Semiconductor operating devicewith semiconductor make contact

N. Segno grafico Symbol Descrizione Description

07-27-01 Accoppiatore con separazioneelettrica1. L’asterisco (*) deve essere sosti-tuito dal segno del mezzo di accop-piamento o deve essere omesso.2. X e Y devono essere sostituitidalle indicazioni corrispondentialle grandezze interessate o de-vono essere omesse.3. La barra doppia può essere so-stituita da una diagonale doppia.

Coupling device with electricalseparation1. The asterisk (*) shall either bereplaced by the symbol for thecoupling medium or be omitted.2. X and Y shall either be replacedby the appropriate indications forthe quantities concerned or beomitted. 3. The double solidusmay be replaced by a double di-agonal.

07-27-02 ESEMPIO:Accoppiatore ottico con separazioneelettrica

EXAMPLE:Optical coupling device withelectrical separation

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 33 di 48

VECCHI SIMBOLILa presente appendice contiene i segni graficinormalizzati della Pubblicazione IEC 617-7 (1983)che sono stati cancellati. Sono rappresentati qui diseguito soltanto per facilitare la comprensione deivecchi schemi.

(Nella presente appendice, i numeri della Pubbli-cazione del 1983 sono tra parentesi).

CONTATTI FUNZIONANTI PER EFFETTO DELLE VARIAZIONI DI VELOCITÀ E CONTATTI IN AMPOLLA DI MERCURIO

SEGNI GRAFICI A BLOCCO PER AVVIATORI DI MOTORI

ANNEX/ALLEGATO

A OLDER SYMBOLSThis annex contains symbols standardized inIEC 617-7 (1983), which are now deleted. Theyare shown here for information purposes onlyto facilitate the comprehension of older dia-grams.

(In this annex the numbering from 1983-editionis quoted in parentheses.)

A.1 SPEED CHANGE SENSITIVE CONTACTS, MERCURY AND LEVELLING SWITCHES

A.2 BLOCK SYMBOLS FOR MOTOR STARTERS

N. Segno grafico Symbol Descrizione Description

07-A1-01

(07-10-01)

Contatto funzionante per inerzia(per es. comandato da una bruscadecelerazione)

Inertia switch (operated by sud-den deceleration)

07-A1-02

(07-10-02)

Contatto a mercurio a tre terminali Mercury switch, three terminalsLevelling switch, three terminals

07-A1-03

(07-10-03)

Contatto a mercurio a quattroterminali

Mercury switch, four terminalsLevelling switch, four terminals

N. Segno grafico Symbol Descrizione Description

07-A2-01

(07-14-04)

Avviatore con ritorno automatico Starter with automatic release

informativeinformativo

NORMA TECNICACEI EN 60617-7:1998-03Pagina 34 di 48

ESTINTORI

BOBINE D’ACCENSIONE E INDICATORI A CARTELLINO

A.3 FIRE-EXTINGUISHERS

A.4 IGNITERS AND FLAG-INDICATORS

N. Segno grafico Symbol Descrizione Description

07-A3-01

(07-23-01)

Estintore con un solo comando erelativo connettore

Fire-extinguisher: single head withconnector

07-A3-02

(07-23-02)

Estintore con due comandi erelativi connettori

Fire-extinguisher: double headwith connectors

N. Segno grafico Symbol Descrizione Description

07-A4-01

(07-24-01)

Bobina d’accensione di grandepotenza

Ignition unit, high energy

07-A4-02

(07-24-02)

Accenditore a resistenza Squib igniter

07-A4-03

(07-24-03)

Candela di accensione Igniter plug (typical)

07-A4-04

(07-24-04)

Relè a cartellino azionato da unabobina

Coil-operated flag indicator

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 35 di 48

INDICE ALFABETICO INGLESE

18-position rotary wafer switch ................................................................................................ 07-12-02

Alarm circuit, separate, fuse ...................................................................................................... 07-21-05

Alarm contact-fuse, three terminals .......................................................................................... 07-21-04

Alarm, for example, single push-button switch ....................................................................... 07-07-05

Alternating current relay, relay coil ......................................................................................... 07-15-12

Arrester, lightning....................................................................................................................... 07-22-03

Assembly of contacts with delayed operation, contact............................................................ 07-05-06

Auto-reclose relay ...................................................................................................................... 07-18-02

Auto-transformer, motor starter (block symbol) ...................................................................... 07-14-07

Automatic return, break contact................................................................................................ 07-06-03

Automatic return, make contact ................................................................................................ 07-06-01

Automatic return, make contact without it ............................................................................... 07-06-02

Automatic return-function, contact ........................................................................................... 07-01-07

Automatic tripping function, contact ....................................................................................... 07-01-05

Break before make, change over contact ................................................................................. 07-02-04

Break contact.............................................................................................................................. 07-02-03

Break contact which is early to open ....................................................................................... 07-04-04

Break contact which is late to open ........................................................................................ 07-04-03

Break contact with automatic return......................................................................................... 07-06-03

Break contact, delayed, device activated.................................................................................. 07-05-03

Break contact, delayed, device de-activated ............................................................................ 07-05-04

Breaks, two by contact .............................................................................................................. 07-02-09

Bridging, six-position, single pole switch................................................................................. 07-11-09

Buchholz protective device (gas relay) .................................................................................... 07-18-01

Button-operated switch, operated by pushing and by turning ............................................... 07-11-02

Button-operated switch, operated either by pushing or by turning ....................................... 07-11-03

Capacitive proximity detector operating on the approach of solid material ......................... 07-19-03

Change-over break before make contact.................................................................................. 07-02-04

Change-over contact with off-position in the centre .............................................................. 07-02-05

Change-over make before break contact.................................................................................. 07-02-06

Circuit breaker ........................................................................................................................... 07-13-05

Circuit breaker function, contact .............................................................................................. 07-01-02

Complex switch, general symbol .............................................................................................. 07-12-01

Contact opened in the unoperated position............................................................................. 07-13-02

Contact with two breaks............................................................................................................ 07-02-09

Contact with two makes ............................................................................................................ 07-02-08

Contact, assembly of contacts with delayed operation .......................................................... 07-05-06

Contact, automatic return function ........................................................................................... 07-01-07

Contact, automatic tripping function ....................................................................................... 07-01-05

Contact, break ............................................................................................................................ 07-02-03

Contact, break, delayed, device activated ................................................................................ 07-05-03

Contact, break, delayed, device de-activated ........................................................................... 07-05-04

Contact, break, which is early to open..................................................................................... 07-04-04

Contact, break, which is late to open ....................................................................................... 07-04-03

Contact, break, whit automatic return ...................................................................................... 07-06-03

Contact, change-over break before make................................................................................. 07-02-04

Contact, change-over make before break................................................................................. 07-02-06

Contact, change-over, with off-position in the centre.............................................................. 07-02-05

Contact, circuit breaker function............................................................................................... 07-01-02

ANNEX/ALLEGATO

B ENGLISH ALPHABETIC INDEXinformativeinformativo

NORMA TECNICACEI EN 60617-7:1998-03Pagina 36 di 48

Contact, contactor function ....................................................................................................... 07-01-01

Contact, disconnector function ................................................................................................. 07-01-03

Contact, isolating-switch function ............................................................................................ 07-01-04

Contact, isolator function........................................................................................................... 07-01-03

Contact, main break, of a contactor.......................................................................................... 07-13-04

Contact, mainmake, of a contactor .......................................................................................... 07-13-02

Contact, make............................................................................................................................. 07-02-01

Contact, make, delayed both, device activated and de-activated .......................................... 07-05-05

Contact, make, delayed, device activated................................................................................. 07-05-01

Contact, make, delayed, device de-activated ........................................................................... 07-05-02

Contact, make, which is early to close .................................................................................... 07-04-01

Contact, make, which is late to close ...................................................................................... 07-04-02

Contact, make, with automatic return....................................................................................... 07-06-01

Contact, make, without automatic return ................................................................................. 07-06-02

Contact, non-automatic return function.................................................................................... 07-01-08

Contact, passing make, closing momentarily during operation .............................................. 07-03-01

Contact, passing make, closing momentarily during operation and release .......................... 07-03-03

Contact, passing make, closing momentarily during release .................................................. 07-03-02

Contact, position switch function.............................................................................................. 07-01-06

Contact, positive operation of a switch .................................................................................... 07-01-09

Contact, spring return function ................................................................................................. 07-01-07

Contact, stay put function.......................................................................................................... 07-01-08

Contact, stay put, make ............................................................................................................ 07-06-02

Contact, switch-disconnector function...................................................................................... 07-01-04

Contact, two-way ...................................................................................................................... 07-06-04

Contactor ................................................................................................................................... 07-13-02

Contactor closed in the unoperated position ........................................................................... 07-13-04

Contactor function ..................................................................................................................... 07-01-01

Contactor with automatic tripping ........................................................................................... 07-13-03

Coupling device with electrical separation............................................................................... 07-27-01

Coupling device, optical, with electrical separation ................................................................ 07-27-02

Cumulative parallel switching, multipole switch, single-pole multi-position ......................... 07-11-12

Current between neutrals of two polyphase systems .............................................................. 07-16-09

Current in the neutral conductor .............................................................................................. 07-16-08

Delayed both, device activated and de-activated, make contact ............................................ 07-05-05

Delayed break contact, device activated ................................................................................. 07-05-03

Delayed break contact, device de-activated............................................................................. 07-05-04

Delayed make contact, device activated ................................................................................. 07-05-01

Delayed make contact, device de-activated ............................................................................. 07-05-02

Delayed operation, assembly of contacts, contact ................................................................... 07-05-06

Delayed overcurrent, example, measuring relais..................................................................... 07-17-04

Device for auto-reclosing ......................................................................................................... 07-18-02

Device related to a measuring relay ......................................................................................... 07-16-01

Device, switch, power switching .............................................................................................. 07-13-00

Differential current..................................................................................................................... 07-16-05

Discharge of gas, protective, tube ........................................................................................... 07-22-04

Disconnector (Isolator) ............................................................................................................. 07-13-06

Disconnector (Isolator), manually operated............................................................................. 07-13-10

Disconnector (Isolator), two-way.............................................................................................. 07-13-07

Divided-conductor detection relay, example, measuring relay ............................................. 07-17-11

Double spark gap ...................................................................................................................... 07-22-02

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 37 di 48

Early to close make contact....................................................................................................... 07-04-01

Early to open break contact ...................................................................................................... 07-04-04

Earth fault current ...................................................................................................................... 07-16-07

Electronic relay, operating device............................................................................................. 07-15-22

Emergency stop switch .............................................................................................................. 07-07-06

Emergency stop switch, mushroom-head (activated by) ........................................................ 07-07-06

Failure to frame, voltage (frame potential in case of fault) ..................................................... 07-16-02

Fluorescent lamp, starter............................................................................................................ 07-09-04

Four-position switch with four independent circuits .............................................................. 07-11-07

Function circuit breaker............................................................................................................. 07-01-02

Function, automatic return ....................................................................................................... 07-01-07

Function, automatic tripping ..................................................................................................... 07-01-05

Function, contactor ................................................................................................................... 07-01-01

Function, disconnector (isolator) ............................................................................................. 07-01-03

Function, isolating-switch, switch-disconnector ...................................................................... 07-01-04

Function, isolator, disconnector ................................................................................................ 07-01-03

Function, non-automatic return................................................................................................. 07-01-08

Function, position switch........................................................................................................... 07-01-06

Function, positive operation of a switch ................................................................................. 07-01-09

Function, positive switch operation ......................................................................................... 07-02-01

Function, spring return ............................................................................................................. 07-01-07

Function, stay put....................................................................................................................... 07-01-08

Function, switch-disconnector (Isolating-switch)..................................................................... 07-01-04

Function, tripping, automatic .................................................................................................... 07-01-05

Fuse isolator ............................................................................................................................... 07-21-08

Fuse switch-disconnector ......................................................................................................... 07-21-09

Fuse with alarm contact, three terminals.................................................................................. 07-21-04

Fuse with mechanical linkage .................................................................................................. 07-21-03

Fuse with separate alarm circuit................................................................................................ 07-21-05

Fuse, general symbol ................................................................................................................ 07-21-01

Fuse-disconnector ...................................................................................................................... 07-21-08

Fuse-switch................................................................................................................................. 07-21-07

Fuses, three-pole switch with automatic release by any one of the striker fuses.................. 07-21-06

Gap, spark ................................................................................................................................. 07-22-01

Gas discharge tube with thermal element ................................................................................ 07-09-04

Gas discharge tube, protective .................................................................................................. 07-22-04

Gas relay..................................................................................................................................... 07-18-01

High speed relay (fast-operating and fast-releasing), relay coil ............................................. 07-15-10

Inverse time-lag characteristic ................................................................................................... 07-16-11

Iron-approaching-operated proximity switch, brake contact ................................................. 07-21-02

Isolating-switch function, contact ............................................................................................ 07-01-04

Isolator ....................................................................................................................................... 07-13-06

Isolator function, contact .......................................................................................................... 07-01-03

Isolator, manually operated disconnector ............................................................................... 07-13-10

Isolator, two-way ....................................................................................................................... 07-13-07

Latched relay, mechanically, relay coil .................................................................................... 07-15-14

Late to close make contact ........................................................................................................ 07-04-02

Late to open break contact........................................................................................................ 07-04-03

Lever-operated switch................................................................................................................ 07-11-01

Light emitting diode as actuator, static relay ............................................................................ 07-26-02

Lightning arrester ....................................................................................................................... 07-22-03

NORMA TECNICACEI EN 60617-7:1998-03Pagina 38 di 48

Limit switch with positive opening operation of the break contact ....................................... 07-08-04

Limit switch, break contact........................................................................................................ 07-08-02

Limit switch, make contact ........................................................................................................ 07-08-01

Limit switch, mechanically operated in both directions with two separate circuits............... 07-08-03

Locked rotor detection relay, example, measuring relay ....................................................... 07-17-13

Magnet-approaching-operated proximity switch, make contact ............................................. 07-20-03

Make before break, contact, change-over ............................................................................... 07-02-06

Make contact .............................................................................................................................. 07-02-01

Make contact which is early to close ....................................................................................... 07-04-01

Make contact which is late to close ......................................................................................... 07-04-02

Make contact with automatic return ......................................................................................... 07-06-01

Make contact without automatic return.................................................................................... 07-06-02

Make contact, delayed both, device activated and de-activated............................................. 07-05-05

Make contact, delayed, device activated .................................................................................. 07-05-00

Make contact, delayed, device de-activated ............................................................................. 07-05-02

Make contact, passing, closing momentarily during operation............................................... 07-03-01

Make contact, passing, closing momentarily during operation and release........................... 07-03-03

Make contact, passing, closing momentarily during release .................................................. 07-03-02

Make contact, stay put ............................................................................................................... 07-06-02

Makes, two by contact ............................................................................................................... 07-02-08

Manually operated switch, general symbol ............................................................................. 07-07-01

Measuring relay .......................................................................................................................... 07-16-01

Mechanical linkage-fuse ............................................................................................................ 07-21-03

Mechanically operated limit switch, both directions with two seperate circuits ................... 07-08-03

Momentarily closing during operation and release contact, passing make............................ 07-03-03

Momentarily closing during operation contact, passing make ............................................... 07-03-01

Momentarily closing during release contact, passing make ................................................... 07-03-02

Motor starter, general symbol ................................................................................................... 07-14-01

Motor with a spring storage operating a three-pole mechanical switching device ............... 07-13-13

Multi-position switch.................................................................................................................. 07-11-04

Multi-position switch (small number of positions) ................................................................. 07-11-05

Multi-position switch, bridging ................................................................................................ 07-11-11

Multipole switch, one of a six-position multipole-switch ...................................................... 07-11-13

Mushroom-head, emergency stop Switch (activated by)......................................................... 07-07-06

No voltage, example, measuring relay ..................................................................................... 07-17-01

Non-Automatic return function ................................................................................................. 07-01-08

Off-position in the centre, change-over contact ...................................................................... 07-02-05

On-load isolating fuse switch.................................................................................................... 07-21-09

On-load isolating switch, switch-disconnector, power switching device ............................... 07-13-08

One pole of a six-position multi-pole switch ......................................................................... 07-11-13

Operating device of a thermal relay ......................................................................................... 07-15-21

Operating device of an electronic relay ................................................................................... 07-15-22

Operating device with two separate windings, attached representation................................ 07-15-03

Operating device with two separate windings, detached representation............................... 07-15-05

Operating device, general symbol ............................................................................................ 07-15-01

Optical coupling device with electrical separation ................................................................. 07-27-02

Overcurrent relay with two measuring elements .................................................................... 07-17-05

Overcurrent relay with two output ........................................................................................... 07-17-14

Overcurrent relay, delayed ....................................................................................................... 07-17-04

Overpower for reactive power, measuring relay ..................................................................... 07-17-06

Percentage differential current .................................................................................................. 07-16-06

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 39 di 48

Phase failure detection, measuring relay .................................................................................. 07-17-12

Polarized relay with neutral position, self restoring, operating for either direction of current in the winding .................................................................................................... 07-15-17

Polarized relay with two stable positions ................................................................................ 07-15-18

Polarized relay, relay coil .......................................................................................................... 07-15-15

Polarized relay, self restoring, operating for only one direction of current in the winding . 07-15-16

Position diagram, example, multipole switch........................................................................... 07-11-06

Position switch function, contact ............................................................................................. 07-01-06

Position switch with positive opening operation of the break contact .................................. 07-08-04

Position switch, break contact................................................................................................... 07-08-02

Position switch, make contact ................................................................................................... 07-08-01

Position switch, mechanically operated in both directions with two separate circuits ......... 07-08-03

Positive opening operation of the break contact, limit switch................................................ 07-08-04

Positive operation by single push button switch ..................................................................... 07-07-05

Positive operation, switch.......................................................................................................... 07-01-09

Power at phase angle ............................................................................................................... 07-16-10

Power switching device, circuit breaker................................................................................... 07-13-05

Power switching device, contactor .......................................................................................... 07-13-02

Power switching device, contactor with automatic tripping .................................................. 07-13-03

Power switching device, disconnector (isolator) .................................................................... 07-13-06

Power switching device, disconnector (Isolator), manually operated ................................... 07-13-10

Power switching device, disconnector (isolator), two-way .................................................... 07-13-07

Power switching device, isolator, two-way ............................................................................. 07-13-07

Power switching device, switch ................................................................................................ 07-13-00

Power switching device, switch with positive opening operation ........................................ 07-13-14

Power switching device, switch-disconnector.......................................................................... 07-13-09

Power switching device, switch-disconnector (on-load isolating switch) .............................. 07-13-08

Power switching device, three-pole mechanical, operated by motor or manually with trip-free mechanism ................................................................................................... 07-13-12

Power switching device, three-pole mechanical, operated by motor with a spring storage. 07-13-13

Power switching device, trip-free mechanism ........................................................................ 07-13-11

Protective gas discharge tube .................................................................................................... 07-22-04

Protective gas discharge tube, symmetric ................................................................................ 07-22-05

Proximity detector, capacitive, operating on the approach of solid material ........................ 07-19-03

Proximity sensing device, block symbol ................................................................................. 07-19-02

Proximity sensor ....................................................................................................................... 07-19-01

Proximity switch, make contact ................................................................................................ 07-20-02

Proximity switch, operated on the approach of a magnet, make contact.............................. 07-20-03

Proximity switch, operated on the approach of iron, break contact ...................................... 07-20-04

Pull-switch .................................................................................................................................. 07-07-03

Push-button switch..................................................................................................................... 07-07-02

Push-button switch with positive operation ............................................................................ 07-07-05

Push-button switch, for example: alarm................................................................................... 07-07-05

Push-button switch, single pole ................................................................................................ 07-07-02

Regulator with thyristors, motor starter (block symbol) ......................................................... 07-14-08

Regulator, motor starter (block symbol) ................................................................................... 07-14-03

Relay coil of a high speed relay (fast-operating and fast-releasing) ....................................... 07-15-10

Relay coil of a mechanically latched relay ............................................................................... 07-15-14

Relay coil of a mechanically resonant relay ............................................................................ 07-15-13

Relay coil of a polarized relay................................................................................................... 07-15-15

Relay coil of a relay unaffected by alternating current ........................................................... 07-15-11

Relay coil of a remanent relay ................................................................................................. 07-15-19

NORMA TECNICACEI EN 60617-7:1998-03Pagina 40 di 48

Relay coil of a slow-operating and slow-releasing relay ......................................................... 07-15-09

Relay coil of a slow-operating relay ........................................................................................ 07-15-08

Relay coil of a slow-releasing relay .......................................................................................... 07-15-07

Relay coil of an alternating current relay ................................................................................. 07-15-12

Relay coil, general symbol ....................................................................................................... 07-15-01

Relay, measuring ........................................................................................................................ 07-16-01

Relay, measuring, current with maximum and minimum settings .......................................... 07-17-08

Relay, measuring, delayed overcurrent..................................................................................... 07-17-04

Relay, measuring, divided-conductor detection relay.............................................................. 07-17-11

Relay, measuring, locked-rotor detection ................................................................................. 07-17-13

Relay, measuring, no voltage .................................................................................................... 07-17-01

Relay, measuring, overcurrent with two measuring elements................................................. 07-17-05

Relay, measuring, overcurrent with two output....................................................................... 07-17-14

Relay, measuring, overpower for reactive power .................................................................... 07-17-06

Relay, measuring, phase-failure detection................................................................................ 07-17-12

Relay, measuring, relay detecting short-circuits between windings ....................................... 07-17-10

Relay, measuring, reverse current ............................................................................................. 07-17-02

Relay, measuring, under-impedance......................................................................................... 07-17-09

Relay, measuring, underpower ................................................................................................. 07-17-03

Relay, measuring, undervoltage ............................................................................................... 07-17-07

Relay, static, general symbol ..................................................................................................... 07-26-01

Relay, static, with light emitting diode as actuator .................................................................. 07-26-02

Relay, three-pole thermal overload ......................................................................................... 07-26-03

Remanent relay, relay coil ......................................................................................................... 07-15-19

Residual voltage ......................................................................................................................... 07-16-03

Resonant relay, mechanically, relay coil................................................................................... 07-15-13

Reverse current .......................................................................................................................... 07-16-04

Reverse current, measuring relay .............................................................................................. 07-17-02

Reversing the rotation of a motor by direct-on-line motor starter (block symbol) with contactor ...................................................................................................................... 07-14-05

Rotary drum switch, six position............................................................................................... 07-12-03

Rotary wafer switch, 18-position .............................................................................................. 07-12-02

Self-operating thermal switch, break contact .......................................................................... 07-09-03

Self-operating thermal switch, for example: bimetal ............................................................... 07-09-03

Semiconductor operating device with semiconductor make contact ..................................... 07-26-04

Semiconductor, contactor, static switch .................................................................................... 07-25-00

Sensor, proximity ....................................................................................................................... 07-19-01

Sensor, touch.............................................................................................................................. 07-19-04

Separate windings, two, on operating device, attached representation ................................. 07-15-03

Separate windings, two, on operating device, detached representation ................................ 07-15-05

Separation, electrical, coupling device ..................................................................................... 07-27-01

Short-circuits between windings detected by relay, example, measuring relais .................... 07-17-10

Single-pole multi-position switch for cumulative parallel switching ...................................... 07-11-12

Single-pole multi-position switch, bridging ............................................................................. 07-11-10

Single-pole six-position switch, bridging ................................................................................ 07-11-09

Single-pole, four-position switch ............................................................................................. 07-11-08

Six-position rotary drum switch ............................................................................................... 07-12-03

Slow-operating relay, relay coil................................................................................................. 07-15-08

Slow-releasing relay, relay coil ................................................................................................ 07-15-07

Spark gap.................................................................................................................................... 07-22-01

Spring return function, contact ................................................................................................ 07-01-07

Stable positions, two, polarized relay ...................................................................................... 07-15-18

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 41 di 48

Star-delta motor starter (block symbol) ................................................................................... 07-14-06

Starter for fluorescent lamp ....................................................................................................... 07-09-04

Starter, motor (block symbol), direct-on-line, with contactor for reversing the rotation of a motor ............................................................................................................................ 07-14-05

Starter, motor (block symbol), general symbol ........................................................................ 07-14-01

Starter, motor (block symbol), operating in steps.................................................................... 07-14-02

Starter, motor (block symbol), regulator ................................................................................. 07-14-03

Starter, motor (block symbol), regulator with thyristors .......................................................... 07-14-08

Starter, motor (block symbol), star-delta................................................................................... 07-14-06

Starter, motor (block symbol), with auto-transformer ............................................................ 07-14-07

Static (semiconductor) contactor............................................................................................... 07-25-02

Static relay with light emitting diode as actuator .................................................................... 07-26-02

Static relay, general symbol ....................................................................................................... 07-26-01

Static switch, general symbol .................................................................................................... 07-25-01

Static switch, passing current in one direction only ............................................................... 07-26-00

Stay put function, contact ......................................................................................................... 07-01-08

Stay put make contact................................................................................................................ 07-06-02

Steps-operating motor starter (block symbol) ......................................................................... 07-14-02

Stop switch for case of emergency ........................................................................................... 07-07-06

Striker fuse ................................................................................................................................. 07-21-03

Surge diverter ............................................................................................................................. 07-22-03

Switch ........................................................................................................................................ 07-13-01

Switch, complex, 18-position rotary wafer .............................................................................. 07-12-02

Switch, complex, general symbol ............................................................................................. 07-12-01

Switch, complex, six-position, rotary drum ............................................................................. 07-12-03

Switch, gas discharge tube whit thermal element.................................................................... 07-09-04

Switch, limit, break contact ....................................................................................................... 07-08-02

Switch, limit, make contact........................................................................................................ 07-08-01

Switch, limit, mechanically operated in both directions with two separate circuits .............. 07-08-03

Switch, limit, whit positive opening operation of me break contact ...................................... 07-08-04

Switch, manually operated, general symbol............................................................................. 07-07-01

Switch, multipole, button-operated, operated by pushing and by turning ............................ 07-11-02

Switch, multipole, button-operated, operated either by pushing or by turning .................... 07-11-03

Switch, multipole, example with position diagram.................................................................. 07-11-06

Switch, multipole, four-position, with four independent circuits .......................................... 07-11-07

Switch, multipole, lever-operated ............................................................................................ 07-11-01

Switch, multipole, multi-position ............................................................................................. 07-11-04

Switch, multipole, multi-position (small number of positions) .............................................. 07-11-05

Switch, multipole, multi-position, bridging ............................................................................. 07-11-11

Switch, multipole, one pole of a six-position multi-pole switch............................................. 07-11-13

Switch, multipole, single-pole multi-position for cumulative parallel switching.................... 07-11-12

Switch, position, break contact ................................................................................................ 07-08-02

Switch, position, make contact.................................................................................................. 07-08-01

Switch, position, mechanically operated in both directions with two separate circuits ........ 07-08-03

Switch, position, with positive opening operation of the break contact................................ 07-08-04

Switch, positive operation ........................................................................................................ 07-01-09

Switch, proximity, make contact ............................................................................................... 07-20-02

Switch, proximity, operated on the approach of a magnet, make contact ............................ 07-20-03

Switch, proximity, operated on the approach of iron, break contact..................................... 07-20-04

Switch, self-operating, thermal, break contact ........................................................................ 07-09-03

Switch, self-operating, thermal, for example: bimetal ............................................................. 07-09-03

Switch, single pole, manually operated, general symbol ....................................................... 07-07-01

NORMA TECNICACEI EN 60617-7:1998-03Pagina 42 di 48

Switch, single pole, pull-switch................................................................................................. 07-07-03

Switch, single pole, push-button ............................................................................................. 07-07-02

Switch, single, emergency stop ................................................................................................ 07-07-06

Switch, single, mushroom-head, emergency stop (activated by)............................................ 07-07-06

Switch, single, push-button, for example: alarm...................................................................... 07-07-05

Switch, single, posh-button with positive operation .............................................................. 07-07-05

Switch, single, turn-switch ........................................................................................................ 07-07-04

Switch, single-pole, four-position ............................................................................................ 07-11-08

Switch, single-pole, multi-position, bridging ........................................................................... 07-11-10

Switch, single-pole, six-position, bridging .............................................................................. 07-11-09

Switch, static, (semiconductor) contactor ................................................................................. 07-25-02

Switch, static, general symbol ................................................................................................... 07-25-01

Switch, static, passing current in one direction only ............................................................... 07-25-03

Switch, temperature sensitive, break contact ........................................................................... 07-09-02

Switch, temperature sensitive, make contact............................................................................ 07-09-01

Switch, touch sensitive, make contact ...................................................................................... 07-20-01

Switch, with positive opening operation ................................................................................. 07-13-14

Switch-disconnector ................................................................................................................... 07-13-09

Switch-disconnector (on-load isolating switch) ...................................................................... 07-13-08

Switchgear and controlgear, circuit breaker ............................................................................ 07-13-05

Switchgear and controlgear, contactor...................................................................................... 07-13-02

Switchgear and controlgear, contactor...................................................................................... 07-13-04

Switchgear and controlgear, contactor with automatic tripping ............................................ 07-13-03

Switchgear and controlgear, disconnector (isolator)................................................................ 07-13-06

Switchgear and controlgear, disconnector (isolator), manually operated ............................. 07-13-10

Switchgear and controlgear, disconnector (isolator), two-way ............................................... 07-13-07

Switchgear and controlgear, isolator, two-way......................................................................... 07-13-07

Switchgear and controlgear, switch with positive opening operation ................................... 07-13-14

Switchgear and controlgear, switch-disconnector .................................................................... 07-13-09

Switchgear and controlgear, switch-disconnector (on-load isolating switch) ....................... 07-13-08

Switchgear and controlgear, three-pole mechanical switching device operated by motor with a spring storage .......................................................................................................... 07-13-13

Switchgear and controlgear, trip-free mechanism ................................................................... 07-13-11

Temperature sensitive switch, break contact............................................................................ 07-09-02

Temperature sensitive switch, make contact............................................................................ 07-09-00

Thermal overload, three pole, relay ......................................................................................... 07-26-03

Thermal relay, operating device ............................................................................................... 07-15-21

Thermal switch, self-operating, break contact ......................................................................... 07-09-03

Three-pole mechanical switching device operated by motor or manually with trip-free mechanism........................................................................................................................... 07-13-12

Three-pole mechanical switching device operated by motor whit a spring storage ............. 07-13-13

Three-pole switch with automatic release by any one of the striker fuses, ........................... 07-21-06

Three-pole thermal overload relay ........................................................................................... 07-26-03

Thyristor-regulator, motor starter (block symbol) ................................................................... 07-14-08

Touch sensitive switch, make contact ...................................................................................... 07-20-01

Touch sensor ............................................................................................................................. 07-19-04

Trip-free mechanism .................................................................................................................. 07-13-11

Tube, gas discharge, with thermal element ............................................................................ 07-09-04

Tube, protective gas discharge.................................................................................................. 07-22-04

Tube, protective gas discharge, symmetric............................................................................... 07-22-05

Turn-switch................................................................................................................................. 07-07-04

Two way isolator ....................................................................................................................... 07-13-07

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 43 di 48

Two-way contact........................................................................................................................ 07-06-04

Under-impedance, example, measuring relay ......................................................................... 07-17-09

Underpower, example, measuring relais .................................................................................. 07-17-03

Undervoltage, example, measuring relay ................................................................................. 07-17-07

Voltage failure to frame (frame potential in case of fault)....................................................... 07-16-02

Wafer switch, 18-position, rotary............................................................................................... 07-12-02

Windings, short-circuits between windings detected by relay, measuring relais .................. 07-17-10

NORMA TECNICACEI EN 60617-7:1998-03Pagina 44 di 48

INDICE ALFABETICO ITALIANO

Accoppiatore con separazione elettrica.................................................................................... 07-27-01

Accoppiatore ottico con separazione elettrica ......................................................................... 07-27-02

Apparecchio meccanico, tripolare, motorizzato con memoria automatica............................. 07-13-13

Apparecchio meccanico, tripolare, motorizzato o manuale, con meccanismo ad apertura libera .................................................................................................................................... 07-13-12

Avviatore a gradini ..................................................................................................................... 07-14-02

Avviatore diretto mediante contattore (a piena tensione) per due sensi di marcia ............... 07-14-05

Avviatore mediante autotrasformatore...................................................................................... 07-14-07

Avviatore per motore, segno generale...................................................................................... 07-14-01

Avviatore stella-triangolo ........................................................................................................... 07-14-06

Avviatore-regolatore................................................................................................................... 07-14-03

Avviatore-regolatore a tiristori ................................................................................................... 07-14-08

Bobina di comando con due avvolgimenti separati, rappresentazione raggruppata............. 07-15-02

Bobina di comando con due avvolgimenti separati, rappresentazione separata................... 07-15-05

Bobina di comando di un relè a corrente alternata................................................................. 07-15-12

Bobina di comando di un relè a rimanenza............................................................................. 07-15-19

Bobina di comando di un relè a risonanza meccanica............................................................ 07-15-13

Bobina di comando di un relè ad aggancio meccanico .......................................................... 07-15-14

Bobina di comando di un relè con ritardo all’attrazione......................................................... 07-15-08

Bobina di comando di un relè con ritardo alla ricaduta ......................................................... 07-15-07

Bobina di comando di un relè con ritardo alla ricaduta e all’attrazione ................................ 07-15-09

Bobina di comando di un relè insensibile alla corrente alternata .......................................... 07-15-11

Bobina di comando di un relè polarizzato............................................................................... 07-15-15

Bobina di comando di un relè rapido (attrazione e ricaduta rapide)..................................... 07-15-10

Bobina di comando, segno generale ........................................................................................ 07-15-01

Caratteristica di ritardo a tempo inverso................................................................................... 07-16-11

Commutatore a 4 posizioni, per 4 circuiti indipendenti, a comando manuale ...................... 07-11-07

Commutatore complesso, segno generale................................................................................ 07-12-01

Commutatore con comando a leva, a tre posizioni, con posizione superiore mantenuta e con ritorno automatico dalla posizione inferiore alla posizione centrale, rappresentato con i suoi terminali...................................................................................... 07-11-01

Commutatore con comando a pulsante.................................................................................... 07-11-02

Commutatore con comando a pulsante.................................................................................... 07-11-03

Commutatore rotativo a pacco, a 18 posizioni e 6 terminali .................................................. 07-12-02

Commutatore rotativo a tamburo a 6 posizioni e a 5 terminali .............................................. 07-12-03

Commutatore unipolare a 4 posizioni, in cui la posizione 2 non può essere connessa ....... 07-11-08

Commutatore unipolare a 6 posizioni con contatto mantenuto nel passaggio da una posizione alla successiva ........................................................................................ 07-11-09

Commutatore unipolare a n posizioni ...................................................................................... 07-11-05

Commutatore unipolare a n posizioni (in figura n = 6).......................................................... 07-11-04

Commutatore unipolare a più posizioni con contatto mantenuto su tre contatti consecutivi in ciascuna posizione ...................................................................................... 07-11-10

Commutatore unipolare a più posizioni con contatto mantenuto su tre contatti contemporaneamente, escludendone uno intermedio, in ciascuna delle posizioni ....... 07-11-11

Commutatore unipolare a più posizioni per la messa in parallelo a effetto cumulativo....... 07-11-12

Contatto a due aperture............................................................................................................. 07-02-09

Contatto a due chiusure ............................................................................................................ 07-02-08

Contatto a due vie e tre posizioni con posizione centrale di interruzione, a ritorno automatico per la posizione di sinistra ed a posizione mantenuta per la posizione di destra ............................................................................................................................... 07-06-04

ANNEX/ALLEGATO

C ITALIAN ALPHABETIC INDEXinformativeinformativo

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 45 di 48

Contatto di apertura ................................................................................................................... 07-02-03

Contatto di apertura a ritorno automatico ................................................................................ 07-06-03

Contatto di apertura anticipato (apre in anticipo rispetto agli altri contatti di uno stesso gruppo) ................................................................................................................................ 07-04-04

Contatto di apertura con comando di arresto di emergenza (azionato da un pulsante con “testa a fungo”) e, a posizione mantenuta, a manovra positiva di apertura............. 07-07-06

Contatto di apertura ritardato (apre in ritardo rispetto agli altri contatti di uno stesso gruppo) ................................................................................................................................ 07-04-03

Contatto di apertura, funzionante per effetto termico diretto (es. bimetallo) ........................ 07-09-03

Contatto di apertura, ritardato all’apertura ............................................................................... 07-05-04

Contatto di apertura, ritardato alla chiusura ............................................................................. 07-05-03

Contatto di apertura, sensibile alla temperatura....................................................................... 07-09-02

Contatto di chiusura................................................................................................................... 07-02-01

Contatto di chiusura a posizione mantenuta ............................................................................ 07-06-02

Contatto di chiusura a ritorno automatico................................................................................ 07-06-01

Contatto di chiusura anticipato (chiude in anticipo rispetto agli altri contatti di uno stesso gruppo) ................................................................................................................................ 07-04-01

Contatto di chiusura con comando a pulsante a manovra positiva di chiusura (per esempio: allarme) ........................................................................................................ 07-07-05

Contatto di chiusura con comando manuale, segno generale ................................................ 07-07-01

Contatto di chiusura ritardato (chiude in ritardo rispetto agli altri contatti di uno stesso gruppo) ................................................................................................................................ 07-04-02

Contatto di chiusura, con comando a pulsante ed a ritorno automatico ............................... 07-07-02

Contatto di chiusura, con comando a tirante ed a ritorno automatico................................... 07-07-03

Contatto di chiusura, con comando rotativo, senza ritorno automatico................................. 07-07-04

Contatto di chiusura, ritardato all’apertura ............................................................................... 07-05-02

Contatto di chiusura, ritardato alla chiusura............................................................................. 07-05-01

Contatto di chiusura, ritardato sia all’apertura che alla chiusura ............................................ 07-05-05

Contatto di chiusura, sensibile alla temperatura ...................................................................... 07-09-01

Contatto di passaggio con chiusura momentanea durante il rilascio...................................... 07-03-02

Contatto di passaggio con chiusura momentanea durante l’azione........................................ 07-03-01

Contatto di passaggio con chiusura momentanea durante l’azione e durante il rilascio....... 07-03-03

Contatto di posizione (fine corsa) a due circuiti separati, azionato meccanicamente nei due sensi........................................................................................................................ 07-08-03

Contatto di posizione con contatto di apertura a manovra positiva di apertura.................... 07-08-04

Contatto di posizione di apertura (fine corsa) ......................................................................... 07-08-02

Contatto di posizione di chiusura (fine corsa) ......................................................................... 07-08-01

Contatto di scambio con interruzione momentanea ................................................................ 07-02-04

Contatto di scambio con posizione d’apertura al centro ......................................................... 07-02-05

Contatto di scambio, senza interruzione................................................................................... 07-02-06

Contattore ad apertura automatica, associato ad un relè di protezione ................................. 07-13-03

Contattore statico (semiconduttore).......................................................................................... 07-25-02

Contattore, contatto di apertura principale (contatto chiuso in condizione di riposo) ......... 07-13-04

Contattore, contatto di chiusura principale (contatto aperto in condizione di riposo) ......... 07-13-02

Corrente di guasto a terra .......................................................................................................... 07-16-07

Corrente di ritorno ..................................................................................................................... 07-16-04

Corrente differenziale ................................................................................................................ 07-16-05

Corrente differenziale (valore relativo)..................................................................................... 07-16-06

Corrente fra i punti neutri di due sistemi polifasi .................................................................... 07-16-09

Corrente nel neutro.................................................................................................................... 07-16-08

Diagramma di posizione, commutatore unipolare................................................................... 07-11-06

Dispositivo di comando di un relè elettronico......................................................................... 07-15-22

NORMA TECNICACEI EN 60617-7:1998-03Pagina 46 di 48

Dispositivo di comando di un relè termico.............................................................................. 07-15-21

Dispositivo di comando semiconduttore con contatto di chiusura con comando semiconduttore .................................................................................................................... 07-26-04

Dispositivo di comando, segno generale ................................................................................. 07-15-01

Dispositivo di prossimità capacitivo che funziona all’avvicinamento di materiale solido..... 07-19-03

Dispositivo di richiusura automatica......................................................................................... 07-18-02

Dispositivo sensibile al tocco, con contatto di chiusura.......................................................... 07-20-01

Dispositivo sensibile alla prossimità, comandato dall’avvicinamento di un magnete, con contatto di chiusura ..................................................................................................... 07-20-03

Dispositivo sensibile alla prossimità, comandato dall’avvicinamento di ferro, con contatto di apertura............................................................................................................................ 07-20-04

Dispositivo sensibile alla prossimità, con contatto di chiusura............................................... 07-20-02

Dispositivo sensibile alla prossimità, segno a blocco.............................................................. 07-19-02

Elemento di un commutatore multipolare a 6 posizioni ......................................................... 07-11-13

Funzione di apertura automatica provocata da un relè o sganciatore di misura incorporati 07-01-05

Funzione di contatto di posizione (fine corsa) ........................................................................ 07-01-06

Funzione di contattore............................................................................................................... 07-01-01

Funzione di interruttore (di potenza) ....................................................................................... 07-01-02

Funzione di interruttore di manovra-sezionatore..................................................................... 07-01-04

Funzione di ritorno automatico, per esempio ritorno a molla................................................ 07-01-07

Funzione di sezionatore ............................................................................................................ 07-01-03

Funzione posizione mantenuta ................................................................................................. 07-01-08

Fusibile (segno generale) .......................................................................................................... 07-21-01

Fusibile con indicazione, mediante tratto con spessore maggiore, dell’estremo che rimane sotto tensione................................................................................................... 07-21-02

Fusibile con percussore ............................................................................................................. 07-21-03

Fusibile con percussore e con circuito di segnalazione, a tre morsetti ................................. 07-21-04

Fusibile con percussore e con circuito di segnalazione separato ........................................... 07-21-05

Insieme di contatti con un contatto di chiusura non ritardato, un contatto di chiusura ritardato all’apertura ed un contatto di apertura ritardato all’apertura ............................. 07-05-06

Interruttore (di potenza) ............................................................................................................ 07-13-05

Interruttore (segno generico per ogni dispositivo meccanico che attua la chiusura o apertura di un circuito).................................................................................................... 07-13-01

Interruttore di manovra con fusibile incorporato (segno generale)........................................ 07-21-07

Interruttore di manovra tripolare con apertura automatica comandata da uno qualunque dei fusibili con percussore .................................................................................................. 07-21-06

Interruttore di manovra-sezionatore ......................................................................................... 07-13-08

Interruttore di manovra-sezionatore ad apertura automatica .................................................. 07-13-09

Interruttore di manovra-sezionatore, con fusibile incorporato................................................ 07-21-09

Interruttore di sicurezza, con tre contatti principali di apertura a manovra positiva e un contatto ausiliario di chiusura senza manovra positiva ............................................ 07-13-14

Interruttore statico, passaggio della corrente in una sola direzione ....................................... 07-25-03

Interruttore statico, segno generale .......................................................................................... 07-25-01

Limitatore di tensione nel gas ................................................................................................... 07-22-04

Limitatore di tensione nel gas, simmetrico ............................................................................... 07-22-05

Manovra positiva di un’apparecchiatura................................................................................... 07-01-09

Meccanismo ad apertura libera ................................................................................................. 07-13-11

Potenza all’angolo di fase a ...................................................................................................... 07-16-10

Relè a mancanza di tensione ................................................................................................... 07-17-01

Relè a corrente di ritorno .......................................................................................................... 07-17-02

Relè Buchholz (a sviluppo di gas) ............................................................................................ 07-18-01

Relè di massima corrente a due uscite, una attivata quando la corrente supera cinque volte il valore di aggiustaggio, l’altra con caratteristica di ritardo a tempo inverso ........ 07-17-14

NORMA TECNICACEI EN 60617-7:1998-03

Pagina 47 di 48

Relè di massima corrente ad azione ritardata........................................................................... 07-17-04

Relè di massima corrente con due elementi di corrente, con campo di aggiustaggio da 5 A a 10 A ....................................................................................................................... 07-17-05

Relè di massima e minima corrente .......................................................................................... 07-17-08

Relè di massima potenza reattiva.............................................................................................. 07-17-06

Relè di minima impedenza........................................................................................................ 07-17-09

Relè di minima potenza attiva ................................................................................................... 07-17-03

Relè di minima tensione ............................................................................................................ 07-17-07

Relè di misura............................................................................................................................. 07-16-01

Relè polarizzato a due posizioni stabili .................................................................................... 07-15-18

Relè polarizzato che funziona per una sola direzione di corrente nell’avvolgimento e che ritorna in posizione di riposo dopo l’interruzione della corrente di comando ..... 07-15-16

Relè polarizzato, con posizione mediana, che funziona per i due sensi della corrente nell’avvolgimento e ritorna nella posizione mediana dopo l’interruzione della corrente di comando.................................................................................................. 07-15-17

Relè rilevatore dell’interruzione di avvolgimento .................................................................... 07-17-11

Relè rilevatore della mancanza di fase in un sistema trifase ................................................... 07-17-12

Relè rilevatore di bloccaggio del rotore mediante misura di corrente.................................... 07-17-13

Relè rilevatore di corto circuito tra spire .................................................................................. 07-17-10

Relè statico comandato da diodo ad emissione luminosa....................................................... 07-26-02

Relè statico, segno generale rappresentato con contatto di chiusura con comando semiconduttore .................................................................................................................... 07-26-01

Relè termico di sovraccarico, trifase ......................................................................................... 07-26-03

Scaricatore .................................................................................................................................. 07-22-03

Sensore al tocco ......................................................................................................................... 07-19-04

Sensore di prossimità ................................................................................................................. 07-19-01

Sezionatore ................................................................................................................................. 07-13-06

Sezionatore a comando manuale, con dispositivo di blocco .................................................. 07-13-10

Sezionatore a due vie e tre posizioni con posizione centrale di apertura.............................. 07-13-07

Sezionatore con fusibile incorporato ........................................................................................ 07-21-08

Spinterometro ............................................................................................................................. 07-22-01

Spinterometro doppio................................................................................................................ 07-22-02

Tensione di guasto a massa....................................................................................................... 07-16-02

Tensione residua ........................................................................................................................ 07-16-03

Tubo a scarica nel gas con bimetallo (starter per lampada fluorescente) .............................. 07-09-04

Fine Documento

NORMA TECNICACEI EN 60617-7:1998-03Totale Pagine 54

La presente Norma è stata compilata dal Comitato Elettrotecnico Italiano e beneficia del riconoscimento di cui alla legge 1º Marzo 1968, n. 186.

Editore CEI, Comitato Elettrotecnico Italiano, Milano - Stampa in proprioAutorizzazione del Tribunale di Milano N. 4093 del 24 luglio 1956

Responsabile: Ing. E. Camagni

Sede del Punto di Vendita e di Consultazione 20126 Milano - Viale Monza, 261tel. 02/25773.1 • fax 02/25773.222 • E-MAIL [email protected]

Lire 135.000

3 – Documentazione e segni grafici

CEI 3 Schemi dei circuiti elettrici degli impianti di segnalamento fer-roviario

CEI 3-5 Segni grafici per trazione elettrica ferroviaria, tranviaria e filov-iaria

CEI 3-7 Segni grafici per i piani schematici di posa dei cavi per tele-comunicazione, segnalamento e sicurezza e per distribuzionedi energia elettrica negli impianti ferrotranviari

CEI 3-8 Sigle e segni grafici per i piani schematici degli impianti di seg-nalamento ferroviario

CEI EN 60617-2 (CEI 3-14) Segni grafici per schemi Parte 2: Elementi dei segni grafici,segni grafici distintivi ed altri segni di uso generale

CEI EN 60617-3 (CEI 3-15) Segni grafici per schemi Parte 3:Conduttori e dispositivi diconnessione

CEI EN 60617-4 (CEI 3-16) Segni grafici per schemi Parte 4: Componenti passivi

CEI EN 60617-5 (CEI 3-17) Segni grafici per schemi Parte 5: Semiconduttori e tubielettronici

CEI EN 60617-6 (CEI 3-18) Segni grafici per schemi Parte 6: Produzione, trasformazionee conversione dell’energia elettrica

CEI 3-19 Segni grafici per schemi Parte 7°: Apparecchiature e disposi-tivi di comando e protezione

CEI 3-20 Segni grafici per schemi Parte 8°: Strumenti di misura, lam-pade e dispositivi di segnalazione

CEI EN 60617-9 (CEI 3-21) Segni grafici per schemi Parte 9: Telecomunicazioni: Apparatidi commutazione e periferiche

CEI 3-22 Segni grafici per schemi Parte 10°: Telecomunicazioni - Tras-missione

CEI 3-23 Segni grafici per schemi Parte 11°: Schemi e piani d’installazi-one architettonici e topografici

CEI EN 60617-13 (CEI 3-24) Segni grafici per schemi Parte 13: Elementi analogici

CEI 3-25 Segni grafici per schemi Parte 1°: Generalità

CEI 3-26 Segni grafici per schemi Parte 12°: Elementi logici binari

CEI 3-27 Segni grafici da utilizzare sulle apparecchiature - Indice, som-mario e compilazione dei singoli fogli

CEI 3-28 Principi generali per l’elaborazione di segni grafici da utilizzaresulle apparecchiature

CEI 3-30 Segni grafici per impianti termoelettrici e nucleotermoelettrici

CEI 3-31 Segni grafici per impianti idroelettrici

CEI 3-34 Codice di identificazione dei materiali da utilizzare nella tecno-logia elettrica

CEI 3-35 Preparazione dei diagrammi funzionali per sistemi di comandoe controllo

CEI EN 61082-1 (CEI 3-36) Preparazione di documenti utilizzati in elettrotecnica. Parte 1:Prescrizioni generali

CEI EN 61175 (CEI 3-37) Designazione di segnali e connessioni

CEI EN 61082-2 (CEI 3-38) Preparazione di documenti utilizzati in elettrotecnica Parte 2:Schemi orientati alla funzione

CEI EN 61082-3 (CEI 3-39) Preparazione di documenti utilizzati in elettrotecnica Parte 3:Schemi, tabelle e liste delle connessioni

CEI EN 61360-1 (CEI 3-40) Tipi normalizzati di elementi di dati con schema di classificazi-one per componenti elettrici Parte 1: Definizioni - Principi emetodi

CEI EN 61286 (CEI 3-41) Tecnica dell’informazione Insieme di caratteri grafici codificatida usare nella preparazione di documenti utilizzati nell’elettro-tecnica e per lo scambio di informazioni

CEI EN 61082-4 (CEI 3-42) Preparazione di documenti utilizzati in elettrotecnica Parte 4:Documenti di disposizione e di installazione

CEI EN 61346-1 (CEI 3-43) Sistemi industriali, installazioni e apparecchi e prodotti indus-triali Principi di strutturazione e designazioni di riferimentoParte 1: Regole di base