TITOLO COMMITTENTE

CONTR.ELAB.

FILE

APPR.

DISEGNO DATA

UNIVERSITÁ SAPIENZA

ROMA

Progetto Impianto ElettricoSchema a blocchi

schema

23/01/2018

FORNITURA DA QUADRO GENERALE

400/230V - 50Hz - Ik = 15 kAQuadripolareSistema TN-SPotenza Contratto 0 kWPotenza Impianto 190 kW

Quadro Generale EDIFICIOQGEN: Ik = 12,26 [kA]Linea: FG16M16 / 30 mSezione: 3(1x185)+(1x95)+(1PE95)C.d.t. con: Ib 0,61 %

QUADRO PTQDPT/NOR.: Ik = 9,27 [kA]Linea: FG16M16/H07Z1-K_2 PE / 20 mSezione: 3(1x50)+(1x25)+(1PE25)C.d.t. con: Ib 1,03 %

QUADRO PTQDPT/PR.: Ik = 1,81 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G4)C.d.t. con: Ib 1,9 %

QUADRO LABORATORIO TECNICOQLT/NOR.: Ik = 4,51 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G10)C.d.t. con: Ib 1,54 %

QUADRO LABORATORIO TECNICOQLT/PR: Ik = 1,81 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G4)C.d.t. con: Ib 2,07 %

QUADRO LABORATORIO AREA PROCESSIQLAP/NOR.: Ik = 5,55 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G16)C.d.t. con: Ib 1,31 %

QUADRO LABORATORIO AREA PROCESSIQLAP.PR: Ik = 2,26 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G6)C.d.t. con: Ib 2,28 %

UPS-PTUPS-PT: Ik = 4,44 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G10)C.d.t. con: Ib 1,59 % ---

UPS

QUADRO P1QDP1/NOR.: Ik = 8,26 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G25)C.d.t. con: Ib 0,9 %

QUADRO P1QDP1/PR.: Ik = 1,29 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G4)C.d.t. con: Ib 2,32 %

UPS P1UPS-P1: Ik = 2,28 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G4)C.d.t. con: Ib 1,66 %

UPS

QUADRO CENTRALE TERMICAQCT: Ik = 9,41 [kA]Linea: FG16M16/H07Z1-K_2 PE / 30 mSezione: 3(1x95)+(1x50)+(1PE50)C.d.t. con: Ib 1,23 %

Computer Giuseppe
Rettangolo
Pierpaolo
Casella di testo
Capitolato: Parte 2 art. 3.8 Elenco Prezzi: Q.E. PT: N.P.3.001; N.P.3.004; N.P.3.005 Q.E. P1: N.P.3.002 Q.E. CENTRALE TERMICA: N.P.3.003
Pierpaolo
Casella di testo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

1 2uni000001UNIVERSITÁ SAPIENZA

ROMA

SCHEMI UNIFILARI

Nelle pagine seguenti sono riportati gli schemi unifilari deiquadri elettrici presenti nell'impianto

Progetto INTEGRA

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18QGEN

2 3

AL FG 3

uni001002UNIVERSITÁ SAPIENZA

ROMA

Quadro Generale EDIFICIO

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 12,157 kA

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QGEN

Quadripolare12,255

400

5015---

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

FORNITURA DA QUADRO GENERALEF C-0

3(1x185)+(1x95)+(1PE95)30

40050

Quadripolare

QGEN C-0

190

306

0,911

100

SIEMENS

VL400.LI.TM

Esecuzione Fissa

MagnetoTermico

315/250 / 315

3 150/1 575/3 150

55 / N.C.

---

Quadripolare

0,65

---

---

---

---

---

---

Q0

L1L2L3N.QGEN.1

CBD.701.2.3.4.T

QDPT/NOR.

QGEN C-1

ALIMENTAZIONE ORDINARIA

QUADRO PT

58

93

0,934

100

SIEMENS

3VA11 L/T TM220 ATFM 3RN/2

Esecuzione Fissa

MagnetoTermico

125/88 / 100

---/---/1 250

25 / N.C.

---

Quadripolare

1,03

FG16M16/H07Z1-K_2 PE

20

143/2U32_/30/0,7

0,700

3(1x50)+(1x25)+(1PE25)

123

Q1

L1L2L3N.QGEN.0

L1L2L3N.QGEN.2

CBD.355.6.7.8.T

QDP1/NOR.

QGEN C-2

ALIMENTAZIONE

QP1

25

42

0,9

100

SIEMENS

3VA10 L/T TM210 FTFM 3R

Esecuzione Fissa

MagnetoTermico

---/--- / 63

---/---/630

16 / N.C.

---

Quadripolare

0,9

FG16OM16

15

143/2M32_/30/0,7

0,700

1(5G25)

74

Q2

L1L2L3N.QGEN.0

L1L2L3N.QGEN.3

QGEN C-3

ALIMENTAZIONE

QCT

107

171

0,9

100

SIEMENS

3VA12 L/T TM240 ATAM 3RN/2

Esecuzione Fissa

MagnetoTermico

200/140 / 200

2 000/1 000/2 000

36 / N.C.

---

Quadripolare

1,23

FG16M16/H07Z1-K_2 PE

30

143/2U31_/30/1

1,000

3(1x95)+(1x50)+(1PE50)

269

Q3

L1L2L3N.QGEN.0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

3 4

AL FG 4

uni002003UNIVERSITÁ SAPIENZA

ROMA

QUADRO PTSEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,256 kA

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QDPT/NOR.

Quadripolare9,27400

5010---

QDPT/NOR.

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

QGENQGEN C-1

3(1x50)+(1x25)+(1PE25)20

40050

QuadripolareCBD.70

1.2.3.4.T

QDPT/NOR. C-0

GENERALE SEZ.

NORMALE

58

93

0,934

70

SIEMENS

3KA71164AA00

Esecuzione Fissa

Sezionatore

---/--- / 125

---/---/---

--- /

---

Quadripolare

1,04

---

---

---

---

---

---

QS0

L1L2L3N.QGEN.1

QDPT/NOR. C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

1,04

---

---

---

---

---

---

QDPT/NOR. C-2

PRESENZA RETE

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 Ridotto

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

1,04

---

---

---

---

---

---

QS

3

2

L1L2L3N.QDPT/NOR..3

CBD.165.6.7.8.T

QLT/NOR.

QDPT/NOR. C-3

ALIMENTAZIONE

QLT

22

36

0,9

100

SIEMENS

5SL44507+5SM26468

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 50

---/---/500

10 / C

0,3 - Cl. A S

Quadripolare

1,54

FG16OM16

15

143/3M13_/30/0,72

0,720

1(5G10)

54

Q3

L1L2L3N.QDPT/NOR..0

Id

L1L2L3N.QDPT/NOR..4

CBD.259.10.11.12.TQLAP/NOR.

QDPT/NOR. C-4

ALIMENTAZIONE

QLAP

19

32

0,9

100

SIEMENS

5SL44637+5SM26468

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 63

---/---/630

10 / C

0,3 - Cl. A S

Quadripolare

1,31

FG16OM16

15

143/3M13_/30/0,72

0,720

1(5G16)

72

Q4

L1L2L3N.QDPT/NOR..0

Id

L1L2L3N.QDPT/NOR..5

CBD.1613.14.15.16.T

UPS-PT

QDPT/NOR. C-5

ALIMENTAZIONE UPS

PIANO TERRA

25

36

0,99

100

SIEMENS

5SY64507+5SM26458

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 50

---/---/500

10 / C

0,3 - Cl. A S

Quadripolare

1,59

FG16OM16

15

143/3M13_/30/0,72

0,720

1(5G10)

54

Q5

L1L2L3N.QDPT/NOR..0

Id

A

L1N.QDPT/NOR..6

CBD.17.18.T

Utenza generica QDPT/NOR. C-6

QDPT/NOR. C-6

AUSILIARI

0,5

2,406

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

15 / C

0,03 - Cl. A

Monofase L1+N

1,06

---

---

---

---

---

---

Q

Id

6

L1N.QDPT/NOR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

4 5

AL FG 5DAL FG 3

uni002004UNIVERSITÁ SAPIENZA

ROMA

QUADRO PTSEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,256 kAA

L3N.QDPT/NOR..7

CBD.419.20.T

Utenza generica QDPT/NOR. C-7

QDPT/NOR. C-7

BATTERIE

DI POST

1,5

7,217

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

15 / C

0,03 - Cl. A

Monofase L3+N

3,12

FG16OM16

25

143/3M13_/30/0,72

0,720

1(3G1,5)

19

Q

Id

7

L3N.QDPT/NOR..0

QDPT/NOR. C-8

GENERALE ILLUMINAZIONE

CORRIDOIO

1,6

7,698

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

11,25 / C

0,03 - Cl. A

Monofase L1+N

1,12

---

---

---

---

---

---

Q

Id

8

L1N.QDPT/NOR..0

L1N.QDPT/NOR..8

CBD.421.22.T

Utenza generica QDPT/NOR. C-9

QDPT/NOR. C-9

ORDINARIA

DEPOSITO

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,3

FG16OM16

7

143/3M13_/30/0,72

0,720

1(3G1,5)

19

L1N.QDPT/NOR..8

CBD.423.24.T

Utenza generica QDPT/NOR. C-10

QDPT/NOR. C-10

ORDINARIA CORRIDOIO

E FILTRO

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,77

FG16OM16

25

143/3M13_/30/0,72

0,720

1(3G1,5)

19

K10

L1N.QDPT/NOR..8

CBD.425.26.T

Utenza generica QDPT/NOR. C-11

QDPT/NOR. C-11

ORDINARIA

DISIMPEGNO

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,77

FG16OM16

25

143/3M13_/30/0,72

0,720

1(3G1,5)

19

K11

L1N.QDPT/NOR..8

CBD.427.28.T

Utenza generica QDPT/NOR. C-12

QDPT/NOR. C-12

EMERGENZA

0,1

0,481

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,25

FG16OM16

25

143/3M13_/30/0,72

0,720

1(3G1,5)

19

A

QDPT/NOR. C-13

GENERALE ILLUMINAZIONE

AREA PROCESSI

0,6

2,887

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

11,25 / C

0,03 - Cl. A

Monofase L1+N

1,07

---

---

---

---

---

---

Q

Id

13

L1N.QDPT/NOR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

5 6

AL FG 6DAL FG 4

uni002005UNIVERSITÁ SAPIENZA

ROMA

QUADRO PTSEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,256 kAAB

L1N.QDPT/NOR..13

CBD.429.30.T

Utenza generica QDPT/NOR. C-14

QDPT/NOR. C-14

ORDINARIA

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,46

FG16OM16

15

143/3M13_/30/0,72

0,720

1(3G1,5)

19

K14

L1N.QDPT/NOR..13

CBD.431.32.T

Utenza generica QDPT/NOR. C-15

QDPT/NOR. C-15

EMERGENZA

0,1

0,481

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,14

FG16OM16

15

143/3M13_/30/0,72

0,720

1(3G1,5)

19

QDPT/NOR. C-16

GENERALE ILLUMINAZIONE

DIDATTICA

0,6

2,887

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

11,25 / C

0,03 - Cl. A

Monofase L2+N

1,07

---

---

---

---

---

---

Q

Id

16

L2N.QDPT/NOR..0

L2N.QDPT/NOR..16

CBD.433.34.T

Utenza generica QDPT/NOR. C-17

QDPT/NOR. C-17

ORDINARIA

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L2+N

1,59

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

K17

L2N.QDPT/NOR..16

CBD.435.36.T

Utenza generica QDPT/NOR. C-18

QDPT/NOR. C-18

EMERGENZA

0,1

0,481

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L2+N

1,17

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

L3N.QDPT/NOR..19

CBD.437.38.T

Utenza generica QDPT/NOR. C-19

QDPT/NOR. C-19

PRESE

FRIGORIFERI

2

9,623

0,9

100

SIEMENS

5SU13567KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L3+N

1,77

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

19

L3N.QDPT/NOR..0

A

L1N.QDPT/NOR..20

CBD.439.40.T

Utenza generica QDPT/NOR. C-20

QDPT/NOR. C-20

PRESE DI

SERVIZIO

2

9,623

0,9

100

SIEMENS

5SU13567KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L1+N

1,77

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

20

L1N.QDPT/NOR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

6 7

AL FG 7DAL FG 5

uni002006UNIVERSITÁ SAPIENZA

ROMA

QUADRO PTSEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,256 kAA

L2N.QDPT/NOR..21

CBD.441.42.T

Utenza generica QDPT/NOR. C-21

QDPT/NOR. C-21

PRESE

SCRIVANIA 1

2

9,623

0,9

100

SIEMENS

5SU13567KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L2+N

1,77

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

21

L2N.QDPT/NOR..0

L3N.QDPT/NOR..22

CBD.443.44.T

Utenza generica QDPT/NOR. C-22

QDPT/NOR. C-22

PRESE

SCRIVANIA 2

2

9,623

0,9

100

SIEMENS

5SU13567KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L3+N

1,77

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

22

L3N.QDPT/NOR..0

L1N.QDPT/NOR..23

CBD.445.46.T

Utenza generica QDPT/NOR. C-23

QDPT/NOR. C-23

PRESE SERVIZIO

SUPP. PROCESSI

2

9,623

0,9

100

SIEMENS

5SU13567KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L1+N

1,77

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

23

L1N.QDPT/NOR..0

L2N.QDPT/NOR..24

CBD.447.48.T

Utenza generica QDPT/NOR. C-24

QDPT/NOR. C-24

RACK

DATI

2

9,623

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

1,74

FG16OM16

10

143/3M13_/30/0,72

0,720

1(3G2,5)

26

Q

Id

24

L2N.QDPT/NOR..0

L3N.QDPT/NOR..25

CBD.49.50.T

QDPT/NOR. C-25

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

1,04

---

---

---

---

---

---

Q

Id

25

L3N.QDPT/NOR..0

L1N.QDPT/NOR..26

CBD.51.52.T

QDPT/NOR. C-26

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L1+N

1,04

---

---

---

---

---

---

Q

Id

26

L1N.QDPT/NOR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QDPT/PR.

QDPT/PR.

7 8

AL FG 8

uni002007UNIVERSITÁ SAPIENZA

ROMA

QUADRO PTSEZIONE PRIVILEGIATASchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 1,802 kA - Id: 0,3 A

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QDPT/PR.

Quadripolare1,812

400

504,5---

QDPT/PR.

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

UPS-PTUPS-PT C-3

1(5G4)15

40050

QuadripolareCBD.6

1.2.3.4.T

QDPT/PR. C-0

GENERALE SEZ.

PRIVILEGIATA

4

9,623

0,9

100

SIEMENS

5TL14320

Esecuzione Fissa

Sezionatore

---/--- / 32

---/---/---

--- /

---

Quadripolare

1,91

---

---

---

---

---

---

QS0

L1L2L3N.UPS-PT.3

QDPT/PR. C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

1,91

---

---

---

---

---

---

QDPT/PR. C-2

PRESENZA RETE

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 Ridotto

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

1,91

---

---

---

---

---

---

QS

3

2

L1N.QDPT/PR..3

CBD.45.6.T

Utenza generica QDPT/PR. C-3

QDPT/PR. C-3

PRESE

SCRIVANIA 1

2

9,623

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

2,64

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

3

L1N.QDPT/PR..0

L2N.QDPT/PR..4

CBD.47.8.T

Utenza generica QDPT/PR. C-4

QDPT/PR. C-4

PRESE

SCRIVANIA 2

2

9,623

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

2,64

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

4

L2N.QDPT/PR..0

L3N.QDPT/PR..5

CBD.9.10.T

QDPT/PR. C-5

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

1,91

---

---

---

---

---

---

Q

Id

5

L3N.QDPT/PR..0

A

L1N.QDPT/PR..6

CBD.11.12.T

QDPT/PR. C-6

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L1+N

1,91

---

---

---

---

---

---

Q

Id

6

L1N.QDPT/PR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

8 9

AL FG 9

uni003008UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO TECNICOSEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 4,466 kA - Id: 0,3 A

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QLT/NOR.

Quadripolare4,511

400

506

---QLT/NOR.

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

QDPT/NOR.QDPT/NOR. C-3

1(5G10)15

40050

QuadripolareCBD.16

1.2.3.4.T

QLT/NOR. C-0

GENERALE

SEZ. NORMALE

22

36

0,9

70

SIEMENS

5TL16631

Esecuzione Fissa

Sezionatore

---/--- / 63

---/---/---

--- /

---

Quadripolare

1,55

---

---

---

---

---

---

QS0

L1L2L3N.QDPT/NOR..3

QLT/NOR. C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

1,55

---

---

---

---

---

---

QLT/NOR. C-2

PRESENZA RETE

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 Ridotto

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

1,55

---

---

---

---

---

---

QS

3

2

QLT/NOR. C-3

0,6

2,887

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

11,25 / C

0,03 - Cl. A

Monofase L1+N

1,58

---

---

---

---

---

---

Q

Id

3

L1N.QLT/NOR..0

L1N.QLT/NOR..3

CBD.45.6.T

Utenza generica QLT/NOR. C-4

QLT/NOR. C-4

ORDINARIA

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,89

FG16OM16

12

143/2M_3A/30/0,7

0,700

1(3G1,5)

15

L1N.QLT/NOR..3

CBD.47.8.T

Utenza generica QLT/NOR. C-5

QLT/NOR. C-5

EMERGENZA

0,1

0,481

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,62

FG16OM16

8

143/2M_3A/30/0,7

0,700

1(3G1,5)

15

A

L2N.QLT/NOR..6

CBD.49.10.T

Utenza generica QLT/NOR. C-6

QLT/NOR. C-6

FRIGO

COMBINATO

1,5

7,217

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

2,08

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

6

L2N.QLT/NOR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

9 10

AL FG 10DAL FG 8

uni003009UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO TECNICOSEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 4,466 kA - Id: 0,3 AA

L3N.QLT/NOR..7

CBD.411.12.T

Utenza generica QLT/NOR. C-7

QLT/NOR. C-7

ULTRACENTRIFUGA

1,5

7,217

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

2,08

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

7

L3N.QLT/NOR..0

L1N.QLT/NOR..8

CBD.413.14.T

Utenza generica QLT/NOR. C-8

QLT/NOR. C-8

AUTOCLAVE

PICCOLA

1,5

7,217

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

2,08

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

8

L1N.QLT/NOR..0

L2N.QLT/NOR..9

CBD.415.16.T

Utenza generica QLT/NOR. C-9

QLT/NOR. C-9

INCUB.

PIASTRE

1,5

7,217

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

2,08

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

9

L2N.QLT/NOR..0

L3N.QLT/NOR..10

CBD.417.18.T

Utenza generica QLT/NOR. C-10

QLT/NOR. C-10

LIOFILIZZATORE

1,5

7,217

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

2,08

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

10

L3N.QLT/NOR..0

L1N.QLT/NOR..11

CBD.419.20.T

Utenza generica QLT/NOR. C-11

QLT/NOR. C-11

SIST PURIFIC.

H2O

1,5

7,217

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

2,08

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

11

L1N.QLT/NOR..0

L2N.QLT/NOR..12

CBD.421.22.T

Utenza generica QLT/NOR. C-12

QLT/NOR. C-12

CABINA A FLUSSO

LAMINARE

1,5

7,217

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

2,08

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

12

L2N.QLT/NOR..0

A

L3N.QLT/NOR..13

CBD.423.24.T

Utenza generica QLT/NOR. C-13

QLT/NOR. C-13

AUTOCLAVE

GRANDE

1,5

7,217

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

2,08

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

13

L3N.QLT/NOR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

10 11

AL FG 11DAL FG 9

uni003010UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO TECNICOSEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 4,466 kA - Id: 0,3 AA

L1N.QLT/NOR..14

CBD.425.26.T

Utenza generica QLT/NOR. C-14

QLT/NOR. C-14

BANCO 1

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

2,7

FG16OM16

10

143/2M_3A/30/0,65

0,650

1(3G2,5)

20

Q

Id

14

L1N.QLT/NOR..0

L2N.QLT/NOR..15

CBD.427.28.T

Utenza generica QLT/NOR. C-15

QLT/NOR. C-15

BANCO 2

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

2,7

FG16OM16

10

143/2M_3A/30/0,65

0,650

1(3G2,5)

20

Q

Id

15

L2N.QLT/NOR..0

L3N.QLT/NOR..16

CBD.429.30.T

Utenza generica QLT/NOR. C-16

QLT/NOR. C-16

BANCO 3

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

2,7

FG16OM16

10

143/2M_3A/30/0,65

0,650

1(3G2,5)

20

Q

Id

16

L3N.QLT/NOR..0

L1L2L3N.QLT/NOR..17

CBD.1031.32.33.34.T

Utenza generica QLT/NOR. C-17

QLT/NOR. C-17

LAVAVETRERIA

10

16

0,9

100

SIEMENS

5SL44257+5SM23436

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 25

---/---/250

10 / C

0,03 - Cl. A

Quadripolare

1,94

FG16OM16

15

143/1M__2/30/0,7

0,700

1(5G6)

27

Q17

L1L2L3N.QLT/NOR..0

Id

L3N.QLT/NOR..18

CBD.435.36.T

Utenza generica QLT/NOR. C-18

QLT/NOR. C-18

PRESE DI

SERVIZIO

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

1,55

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

18

L3N.QLT/NOR..0

L1N.QLT/NOR..19

CBD.37.38.T

QLT/NOR. C-19

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

1,55

---

---

---

---

---

---

Q

Id

19

L1N.QLT/NOR..0

A

L2N.QLT/NOR..20

CBD.39.40.T

QLT/NOR. C-20

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L2+N

1,55

---

---

---

---

---

---

Q

Id

20

L2N.QLT/NOR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

11 12

AL FG 12DAL FG 10

uni003011UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO TECNICOSEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 4,466 kA - Id: 0,3 AA

L3N.QLT/NOR..21

CBD.41.42.T

QLT/NOR. C-21

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L3+N

1,55

---

---

---

---

---

---

Q

Id

21

L3N.QLT/NOR..0

Computer Giuseppe
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLT/PR

QLT/PR

12 13

AL FG 13

uni003012UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO TECNICOSEZIONE PRIVILEGIATASchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 1,802 kA - Id: 0,3 A

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QLT/PR

Quadripolare1,812

400

504,5---

QLT/PR

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

UPS-PTUPS-PT C-1

1(5G4)15

40050

QuadripolareCBD.6

1.2.3.4.T

QLT/PR C-0

GENERALE

SEZ. PRIVILEGIATA

9

14

0,9

100

SIEMENS

5TL14320

Esecuzione Fissa

Sezionatore

---/--- / 32

---/---/---

--- /

---

Quadripolare

2,08

---

---

---

---

---

---

QS0

L1L2L3N.UPS-PT.1

QLT/PR C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

2,08

---

---

---

---

---

---

QLT/PR C-2

PRESENZA RETE

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 Ridotto

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

2,08

---

---

---

---

---

---

QS

3

2

L1N.QLT/PR.3

CBD.45.6.T

Utenza generica QLT/PR C-3

QLT/PR C-3

BANCO 1

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

3,21

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

3

L1N.QLT/PR.0

L2N.QLT/PR.4

CBD.47.8.T

Utenza generica QLT/PR C-4

QLT/PR C-4

BANCO 2

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

3,21

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

4

L2N.QLT/PR.0

L3N.QLT/PR.5

CBD.49.10.T

Utenza generica QLT/PR C-5

QLT/PR C-5

BANCO 3

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

3,21

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

5

L3N.QLT/PR.0

A

L1N.QLT/PR.6

CBD.11.12.T

QLT/PR C-6

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

2,08

---

---

---

---

---

---

Q

Id

6

L1N.QLT/PR.0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLT/PR

QLT/PR

13 14

AL FG 14DAL FG 12

uni003013UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO TECNICOSEZIONE PRIVILEGIATASchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 1,802 kA - Id: 0,3 AA

L2N.QLT/PR.7

CBD.13.14.T

QLT/PR C-7

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L2+N

2,08

---

---

---

---

---

---

Q

Id

7

L2N.QLT/PR.0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

14 15

AL FG 15

uni004014UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO AREA PROCESSISEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 5,488 kA - Id: 0,3 A

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QLAP/NOR.

Quadripolare5,553

400

506

---QLAP/NOR.

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

QDPT/NOR.QDPT/NOR. C-4

1(5G16)15

40050

QuadripolareCBD.25

1.2.3.4.T

QLAP/NOR. C-0

GENERALE

SEZ. NORMALE

19

32

0,9

100

SIEMENS

5TL16631

Esecuzione Fissa

Sezionatore

---/--- / 63

---/---/---

--- /

---

Quadripolare

1,32

---

---

---

---

---

---

QS0

L1L2L3N.QDPT/NOR..4

QLAP/NOR. C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

1,32

---

---

---

---

---

---

QLAP/NOR. C-2

PRESENZA RETE

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 Ridotto

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

1,32

---

---

---

---

---

---

QS

3

2

QLAP/NOR. C-3

0,6

2,887

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

11,25 / C

0,03 - Cl. A

Monofase L1+N

1,35

---

---

---

---

---

---

Q

Id

3

L1N.QLAP/NOR..0

L1N.QLAP/NOR..3

CBD.45.6.T

Utenza generica QLAP/NOR. C-4

QLAP/NOR. C-4

ORDINARIA

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,66

FG16OM16

12

143/2M_3A/30/0,7

0,700

1(3G1,5)

15

K4

L1N.QLAP/NOR..3

CBD.47.8.T

Utenza generica QLAP/NOR. C-5

QLAP/NOR. C-5

EMERGENZA

0,1

0,481

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,41

FG16OM16

12

143/2M_3A/30/0,7

0,700

1(3G1,5)

15

A

L2N.QLAP/NOR..6

CBD.49.10.T

Utenza generica QLAP/NOR. C-6

QLAP/NOR. C-6

BANCO 1

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

2,45

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

6

L2N.QLAP/NOR..0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

15 16

AL FG 16DAL FG 14

uni004015UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO AREA PROCESSISEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 5,488 kA - Id: 0,3 AA

L3N.QLAP/NOR..7

CBD.411.12.T

Utenza generica QLAP/NOR. C-7

QLAP/NOR. C-7

BANCO 2

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

2,45

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

7

L3N.QLAP/NOR..0

L1N.QLAP/NOR..8

CBD.413.14.T

Utenza generica QLAP/NOR. C-8

QLAP/NOR. C-8

BANCO 3

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

2,45

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

8

L1N.QLAP/NOR..0

L2N.QLAP/NOR..9

CBD.415.16.T

Utenza generica QLAP/NOR. C-9

QLAP/NOR. C-9

BANCO 4

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

2,45

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

9

L2N.QLAP/NOR..0

L3N.QLAP/NOR..10

CBD.417.18.T

Utenza generica QLAP/NOR. C-10

QLAP/NOR. C-10

BANCO 5

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

2,45

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

10

L3N.QLAP/NOR..0

L1N.QLAP/NOR..11

CBD.419.20.T

Utenza generica QLAP/NOR. C-11

QLAP/NOR. C-11

PRESE DI

SERVIZIO

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

2,5

FG16OM16

10

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

11

L1N.QLAP/NOR..0

L2N.QLAP/NOR..12

CBD.21.22.T

Utenza generica QLAP/NOR. C-12

QLAP/NOR. C-12

AUSILIARI

0,2

0,962

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

1,32

---

---

---

---

---

---

Q

Id

12

L2N.QLAP/NOR..0

A

L3N.QLAP/NOR..13

CBD.23.24.T

QLAP/NOR. C-13

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

1,32

---

---

---

---

---

---

Q

Id

13

L3N.QLAP/NOR..0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

16 17

AL FG 17DAL FG 15

uni004016UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO AREA PROCESSISEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 5,488 kA - Id: 0,3 AA

L1N.QLAP/NOR..14

CBD.25.26.T

QLAP/NOR. C-14

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

1,32

---

---

---

---

---

---

Q

Id

14

L1N.QLAP/NOR..0

L2N.QLAP/NOR..15

CBD.27.28.T

QLAP/NOR. C-15

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L2+N

1,32

---

---

---

---

---

---

Q

Id

15

L2N.QLAP/NOR..0

L3N.QLAP/NOR..16

CBD.29.30.T

QLAP/NOR. C-16

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L3+N

1,32

---

---

---

---

---

---

Q

Id

16

L3N.QLAP/NOR..0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLAP/PR.

QLAP.PR

17 18

AL FG 18

uni004017UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO AREA PROCESSISEZIONE PRIVILEGIATASchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 2,248 kA - Id: 0,3 A

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QLAP.PR

Quadripolare2,26400

504,5---

QLAP/PR.

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

UPS-PTUPS-PT C-2

1(5G6)15

40050

QuadripolareCBD.10

1.2.3.4.T

QLAP.PR C-0

GENERALE

SEZ. PRIVILEGIATA

15

29

0,9

100

SIEMENS

5TL14400

Esecuzione Fissa

Sezionatore

---/--- / 40

---/---/---

--- /

---

Quadripolare

2,29

---

---

---

---

---

---

QS0

L1L2L3N.UPS-PT.2

QLAP.PR C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

2,29

---

---

---

---

---

---

QLAP.PR C-2

PRESENZA RETE

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 Ridotto

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

2,29

---

---

---

---

---

---

QS

3

2

L1N.QLAP.PR.3

CBD.45.6.T

Utenza generica QLAP.PR C-3

QLAP.PR C-3

BANCO 1

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

3,42

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

3

L1N.QLAP.PR.0

L2N.QLAP.PR.4

CBD.47.8.T

Utenza generica QLAP.PR C-4

QLAP.PR C-4

BANCO 2

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

3,42

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

4

L2N.QLAP.PR.0

L3N.QLAP.PR.5

CBD.49.10.T

Utenza generica QLAP.PR C-5

QLAP.PR C-5

BANCO 3

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

3,42

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

5

L3N.QLAP.PR.0

A

L1N.QLAP.PR.6

CBD.411.12.T

Utenza generica QLAP.PR C-6

QLAP.PR C-6

BANCO 4

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L1+N

3,42

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

6

L1N.QLAP.PR.0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QLAP/PR.

QLAP.PR

18 19

AL FG 19DAL FG 17

uni004018UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO AREA PROCESSISEZIONE PRIVILEGIATASchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 2,248 kA - Id: 0,3 AA

L2N.QLAP.PR.7

CBD.413.14.T

Utenza generica QLAP.PR C-7

QLAP.PR C-7

BANCO 5

3

14

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L2+N

3,42

FG16OM16

10

143/2M_3A/30/0,7

0,700

1(3G2,5)

21

Q

Id

7

L2N.QLAP.PR.0

L3N.QLAP.PR.8

CBD.15.16.T

QLAP.PR C-8

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

2,29

---

---

---

---

---

---

Q

Id

8

L3N.QLAP.PR.0

L1N.QLAP.PR.9

CBD.17.18.T

QLAP.PR C-9

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L1+N

2,29

---

---

---

---

---

---

Q

Id

9

L1N.QLAP.PR.0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

UPS ESCLUSO DALLA FORNITURA E POSA IN OPERA

23/0

1/20

18

IEE-02-18

UPS-PT

UPS-PT

19 20

AL FG 20

uni005019UNIVERSITÁ SAPIENZA

ROMA

UPS-PT

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 4,439 kA - Id: 0,3 A

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: UPS-PT

Quadripolare4,439

400

504,5---

UPS-PT

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

QDPT/NOR.QDPT/NOR. C-5

1(5G10)15

40050

QuadripolareCBD.16

1.2.3.4.T

UPS-PT C-0

L1L2L3N.UPS-PT.1

CBD.65.6.7.8.TQLT/PR

UPS-PT C-1

ALIM. SEZ. PRIVILEGIATA

QLT

9

14

0,9

100

SIEMENS

5SL44257

Esecuzione Fissa

MagnetoTermico

---/--- / 25

---/---/250

10 / C

---

Quadripolare

2,07

FG16OM16

15

143/3M13_/30/0,72

0,720

1(5G4)

30

Q1

L1L2L3N.UPS-PT.2

CBD.109.10.11.12.T

QLAP.PR

UPS-PT C-2

ALIMENTAZ. SEZ. PRIV.

QLAP

15

29

0,9

100

SIEMENS

5SL44327

Esecuzione Fissa

MagnetoTermico

---/--- / 32

---/---/320

10 / C

---

Quadripolare

2,28

FG16OM16

15

143/3M13_/30/0,72

0,720

1(5G6)

39

Q2

L1L2L3N.UPS-PT.3

CBD.613.14.15.16.T

QDPT/PR.

UPS-PT C-3

ALIMENTAZIONE SEZ. PRIV.

QDPT

4

9,623

0,9

100

SIEMENS

5SL44257

Esecuzione Fissa

MagnetoTermico

---/--- / 25

---/---/250

10 / C

---

Quadripolare

1,9

FG16OM16

15

143/3M13_/30/0,72

0,720

1(5G4)

30

Q3

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

20 21

AL FG 21

uni006020UNIVERSITÁ SAPIENZA

ROMA

QUADRO P1SEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 8,135 kA

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QDP1/NOR.

Quadripolare8,257

400

5010---

QDP1/NOR.

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

QGENQGEN C-2

1(5G25)15

40050

QuadripolareCBD.35

1.2.3.4.T

QDP1/NOR. C-0

GENERALE SEZ.

NORMALE

25

42

0,9

100

SIEMENS

5TL16631

Esecuzione Fissa

Sezionatore

---/--- / 63

---/---/---

--- /

---

Quadripolare

0,91

---

---

---

---

---

---

QS0

L1L2L3N.QGEN.2

QDP1/NOR. C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

0,91

---

---

---

---

---

---

QDP1/NOR. C-2

PRESENZA RETE

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 Ridotto

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

0,91

---

---

---

---

---

---

QS

3

2

L1L2L3N.QDP1/NOR..3

CBD.65.6.7.8.TUPS-P1

QDP1/NOR. C-3

ALIMENTAZIONE UPS

PIANO 1

14

22

0,9

100

SIEMENS

5SY64327+5SM26458

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 32

---/---/320

15 / C

0,3 - Cl. A S

Quadripolare

1,66

FG16OM16

15

143/3M13_/30/0,8

0,800

1(5G4)

34

Q3

L1L2L3N.QDP1/NOR..0

Id

QDP1/NOR. C-4

GENERALE ILLUMINAZIONE

CORRIDOIO

0,8

3,849

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

11,25 / C

0,03 - Cl. A

Monofase L3+N

0,95

---

---

---

---

---

---

Q

Id

4

L3N.QDP1/NOR..0

L3N.QDP1/NOR..4

CBD.49.10.T

Utenza generica QDP1/NOR. C-5

QDP1/NOR. C-5

ORDINARIA

CORRIDOIO

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L3+N

1,47

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

K5

AB

L3N.QDP1/NOR..4

CBD.411.12.T

Utenza generica QDP1/NOR. C-6

QDP1/NOR. C-6

ORDINARIA

DISIMPEGNO

0,2

0,962

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L3+N

1,16

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

K6

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

21 22

AL FG 22DAL FG 20

uni006021UNIVERSITÁ SAPIENZA

ROMA

QUADRO P1SEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 8,135 kAAB

L3N.QDP1/NOR..4

CBD.413.14.T

Utenza generica QDP1/NOR. C-7

QDP1/NOR. C-7

EMERGENZA

0,1

0,481

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L3+N

1,05

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

QDP1/NOR. C-8

GENERALE ILLUMINAZIONE

UFFICI E INFORMATICA

0,8

3,849

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

11,25 / C

0,03 - Cl. A

Monofase L1+N

0,95

---

---

---

---

---

---

Q

Id

8

L1N.QDP1/NOR..0

L1N.QDP1/NOR..8

CBD.415.16.T

Utenza generica QDP1/NOR. C-9

QDP1/NOR. C-9

ORDINARIA

UFFICIO 1

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,47

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

K9

L1N.QDP1/NOR..8

CBD.417.18.T

Utenza generica QDP1/NOR. C-10

QDP1/NOR. C-10

ORDINARIA UFF.2 E

INFORMATICA

0,2

0,962

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,16

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

L1N.QDP1/NOR..8

CBD.419.20.T

Utenza generica QDP1/NOR. C-11

QDP1/NOR. C-11

EMERGENZA

0,1

0,481

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L1+N

1,05

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

QDP1/NOR. C-12

GENERALE ILLUMINAZIONE

RIUNIONI E SUPP. TEC.

0,8

3,849

0,9

100

SIEMENS

5SU13537KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

11,25 / C

0,03 - Cl. A

Monofase L3+N

0,95

---

---

---

---

---

---

Q

Id

12

L3N.QDP1/NOR..0

AB

L3N.QDP1/NOR..12

CBD.421.22.T

Utenza generica QDP1/NOR. C-13

QDP1/NOR. C-13

ORDINARIA

RIUNIONI

0,5

2,406

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L3+N

1,47

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

K13

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

22 23

AL FG 23DAL FG 21

uni006022UNIVERSITÁ SAPIENZA

ROMA

QUADRO P1SEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 8,135 kAAB

L3N.QDP1/NOR..12

CBD.423.24.T

Utenza generica QDP1/NOR. C-14

QDP1/NOR. C-14

ORDINARIA SUPPORTO

TECNICO

0,2

0,962

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L3+N

1,16

FG16OM16

20

143/3M13_/30/0,72

0,720

1(3G1,5)

19

L3N.QDP1/NOR..12

CBD.425.26.T

Utenza generica QDP1/NOR. C-15

QDP1/NOR. C-15

EMERGENZA

0,1

0,481

0,9

100

---

---

---

No Protezione

---/--- / ---

---/---/---

--- / ---

---

Monofase L3+N

1,08

FG16OM16

25

143/3M13_/30/0,72

0,720

1(3G1,5)

19

L1N.QDP1/NOR..16

CBD.427.28.T

Utenza generica QDP1/NOR. C-16

QDP1/NOR. C-16

FM FAN COIL

RECUPERATORE

1,5

7,217

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L1+N

1,43

FG16OM16

10

143/3M13_/30/0,72

0,720

1(3G2,5)

26

Q

Id

16

L1N.QDP1/NOR..0

L2N.QDP1/NOR..17

CBD.429.30.T

Utenza generica QDP1/NOR. C-17

QDP1/NOR. C-17

RACK

DATI

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L2+N

1,3

FG16OM16

5

143/3M13_/30/0,72

0,720

1(3G2,5)

26

Q

Id

17

L2N.QDP1/NOR..0

L3N.QDP1/NOR..18

CBD.431.32.T

Utenza generica QDP1/NOR. C-18

QDP1/NOR. C-18

PRESE

DI SERVIZIO

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L3+N

1,97

FG16OM16

15

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

18

L3N.QDP1/NOR..0

L1N.QDP1/NOR..19

CBD.433.34.T

Utenza generica QDP1/NOR. C-19

QDP1/NOR. C-19

FM INFORMATICA

E UFFICI

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L1+N

1,31

FG16OM16

5

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

19

L1N.QDP1/NOR..0

A

L2N.QDP1/NOR..20

CBD.435.36.T

Utenza generica QDP1/NOR. C-20

QDP1/NOR. C-20

FM RIUNIONI

E SUPP. TECNICO

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L2+N

1,31

FG16OM16

5

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

20

L2N.QDP1/NOR..0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

23 24

AL FG 24DAL FG 22

uni006023UNIVERSITÁ SAPIENZA

ROMA

QUADRO P1SEZIONE NORMALESchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 8,135 kAA

L3N.QDP1/NOR..21

CBD.37.38.T

QDP1/NOR. C-21

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

0,91

---

---

---

---

---

---

Q

Id

21

L3N.QDP1/NOR..0

L1N.QDP1/NOR..22

CBD.39.40.T

QDP1/NOR. C-22

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L1+N

0,91

---

---

---

---

---

---

Q

Id

22

L1N.QDP1/NOR..0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QDP1/PR.

QDP1/PR.

24 25

AL FG 25

uni006024UNIVERSITÁ SAPIENZA

ROMA

QUADRO P1SEZIONE PRIVILEGIATASchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 1,29 kA - Id: 0,3 A

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QDP1/PR.

Quadripolare1,295

400

504,5---

QDP1/PR.

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

UPS-P1UPS-P1 C-1

1(5G4)15

40050

QuadripolareCBD.6

1.2.3.4.T

QDP1/PR. C-0

GENERALE SEZ.

PRIVILEGIATA

10

19

0,9

100

SIEMENS

5TL14320

Esecuzione Fissa

Sezionatore

---/--- / 32

---/---/---

--- /

---

Quadripolare

2,33

---

---

---

---

---

---

QS0

L1L2L3N.UPS-P1.1

QDP1/PR. C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

2,33

---

---

---

---

---

---

QDP1/PR. C-2

PRESENZA RETE

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 Ridotto

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

2,33

---

---

---

---

---

---

QS

3

2

L1N.QDP1/PR..3

CBD.45.6.T

Utenza generica QDP1/PR. C-3

QDP1/PR. C-3

FM INFORMATICA

E UFFICI

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L1+N

2,72

FG16OM16

5

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

3

L1N.QDP1/PR..0

L2N.QDP1/PR..4

CBD.47.8.T

Utenza generica QDP1/PR. C-4

QDP1/PR. C-4

FM INFORMATICA

E UFFICI

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L2+N

2,72

FG16OM16

5

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

4

L2N.QDP1/PR..0

L3N.QDP1/PR..5

CBD.49.10.T

Utenza generica QDP1/PR. C-5

QDP1/PR. C-5

FM UFFICIO

1

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L3+N

2,72

FG16OM16

5

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

5

L3N.QDP1/PR..0

A

L1N.QDP1/PR..6

CBD.411.12.T

Utenza generica QDP1/PR. C-6

QDP1/PR. C-6

FM UFFICIO

2

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L1+N

2,72

FG16OM16

5

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

6

L1N.QDP1/PR..0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18

QDP1/PR.

QDP1/PR.

25 26

AL FG 26DAL FG 24

uni006025UNIVERSITÁ SAPIENZA

ROMA

QUADRO P1SEZIONE PRIVILEGIATASchema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 1,29 kA - Id: 0,3 AA

L2N.QDP1/PR..7

CBD.413.14.T

Utenza generica QDP1/PR. C-7

QDP1/PR. C-7

FM SUPPORTO

TECNICO

2

9,623

0,9

100

SIEMENS

5SU13537KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

15 / C

0,03 - Cl. A

Monofase L2+N

2,72

FG16OM16

5

143/1M__2/30/0,7

0,700

1(3G2,5)

18

Q

Id

7

L2N.QDP1/PR..0

L3N.QDP1/PR..8

CBD.15.16.T

QDP1/PR. C-8

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

2,33

---

---

---

---

---

---

Q

Id

8

L3N.QDP1/PR..0

L1N.QDP1/PR..9

CBD.17.18.T

QDP1/PR. C-9

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L1+N

2,33

---

---

---

---

---

---

Q

Id

9

L1N.QDP1/PR..0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

FORNITURA E POSA IN OPERA UPS ESCLUSA DAL'APPALTO

23/0

1/20

18

IEE-02-18

UPS-P1

UPS-P1

26 27

AL FG 27

uni007026UNIVERSITÁ SAPIENZA

ROMA

UPS P1

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 2,278 kA - Id: 0,3 A

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: UPS-P1

Quadripolare2,278

400

504,5---

UPS-P1

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

QDP1/NOR.QDP1/NOR. C-3

1(5G4)15

40050

QuadripolareCBD.6

1.2.3.4.T

UPS-P1 C-0

L1L2L3N.UPS-P1.1

CBD.65.6.7.8.T

QDP1/PR.

UPS-P1 C-1

10

19

0,9

100

SIEMENS

5SL44257

Esecuzione Fissa

MagnetoTermico

---/--- / 25

---/---/250

10 / C

---

Quadripolare

2,32

FG16OM16

15

143/3M13_/30/0,72

0,720

1(5G4)

30

Q1

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18QCT

27 28

AL FG 28

uni008027UNIVERSITÁ SAPIENZA

ROMA

QUADRO CENTRALE TERMICA

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,388 kA

Tensione di isolamento nominale [V]:

Corrente ammissibile 1 s [kA]:Frequenza [Hz]:

Grado di protezione IP:Codice:

Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QCT

Quadripolare9,407

400

5010---

Cavo [mm²]:

Tensione [V]:

Polarita':

Lunghezza [m]:

Partenza:Da Quadro:

Tipo morsetto:Numerazione morsetto:

Frequenza [Hz]:

QGENQGEN C-3

3(1x95)+(1x50)+(1PE50)30

40050

Quadripolare

QCT C-0

GENERALE

QCT

107

171

0,9

100

SIEMENS

3KA71224AA00

Esecuzione Fissa

Sezionatore

---/--- / 200

---/---/---

--- /

---

Quadripolare

1,23

---

---

---

---

---

---

QS0

L1L2L3N.QGEN.3

QCT C-1

SPD

0

0

---

100

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Esecuzione Fissa

Limitatore SPD

---/--- / 0

---/---/---

25 /

---

Quadripolare

1,23

---

---

---

---

---

---

QCT C-2

0

0

---

100

SIEMENS

3NW6 Gr. 10x38 SEGN.

Esecuzione Fissa

Fusibile

---/--- / 2

---/---/4,9

100 / gL

---

Quadripolare

1,23

---

---

---

---

---

---

F 2

L1L2L3N.QCT.0

L1

L2

L3

V

V

V

L1L2L3N.QCT.3

CBD.505.6.7.8.T

Utenza generica QCT C-3

QCT C-3

GRUPPO

FRIGO

60

96

0,9

100

SIEMENS

3VA11 L/T TM210 FTFM 3R

Esecuzione Fissa

MagnetoTermico

---/--- / 125

---/---/1 250

25 / N.C.

---

Quadripolare

2,27

FG16M16/H07Z1-K_2 PE

40

143/2U32_/30/1

1,000

4(1x35)+(1PE35)

144

Q3

L1L2L3N.QCT.0

L1L2L3N.QCT.4

CBD.359.10.11.12.T

Utenza generica QCT C-4

QCT C-4

UTA 1

38

61

0,9

100

SIEMENS

3VA11 L/T TM220 ATFM 3RN/2

Esecuzione Fissa

MagnetoTermico

100/70 / 80

---/---/1 000

25 / N.C.

---

Quadripolare

2,16

FG16M16/H07Z1-K_2 PE

40

143/2U32_/30/0,7

0,700

3(1x25)+(1x16)+(1PE16)

82

Q4

L1L2L3N.QCT.0

QCT C-5

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q5

L1L2L3N.QCT.0

AB

L1L2L3.QCT.6

CBD.413.14.15.T

Utenza generica QCT C-6

QCT C-6

EXT.02

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K6

L1L2L3.QCT.5

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18QCT

28 29

AL FG 29DAL FG 27

uni008028UNIVERSITÁ SAPIENZA

ROMA

QUADRO CENTRALE TERMICA

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAA

QCT C-7

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q7

L1L2L3N.QCT.0

L1L2L3.QCT.8

CBD.416.17.18.T

Utenza generica QCT C-8

QCT C-8

EXT.02

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K8

L1L2L3.QCT.7

QCT C-9

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q9

L1L2L3N.QCT.0

L1L2L3.QCT.10

CBD.419.20.21.T

Utenza generica QCT C-10

QCT C-10

EXT.02

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K10

L1L2L3.QCT.9

QCT C-11

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q11

L1L2L3N.QCT.0

L1L2L3.QCT.12

CBD.422.23.24.T

Utenza generica QCT C-12

QCT C-12

EXT.03

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K12

L1L2L3.QCT.11

A

QCT C-13

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q13

L1L2L3N.QCT.0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18QCT

29 30

AL FG 30DAL FG 28

uni008029UNIVERSITÁ SAPIENZA

ROMA

QUADRO CENTRALE TERMICA

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAAB

L1L2L3.QCT.14

CBD.425.26.27.T

Utenza generica QCT C-14

QCT C-14

EXT.04

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K14

L1L2L3.QCT.13

QCT C-15

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q15

L1L2L3N.QCT.0

L1L2L3.QCT.16

CBD.428.29.30.T

Utenza generica QCT C-16

QCT C-16

EXT.05

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K16

L1L2L3.QCT.15

QCT C-17

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q17

L1L2L3N.QCT.0

L1L2L3.QCT.18

CBD.431.32.33.T

Utenza generica QCT C-18

QCT C-18

EXT.06

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K18

L1L2L3.QCT.17

QCT C-19

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q19

L1L2L3N.QCT.0

AB

L1L2L3.QCT.20

CBD.434.35.36.T

Utenza generica QCT C-20

QCT C-20

EXT.07

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K20

L1L2L3.QCT.19

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18QCT

30 31

AL FG 31DAL FG 29

uni008030UNIVERSITÁ SAPIENZA

ROMA

QUADRO CENTRALE TERMICA

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAA

QCT C-21

0,3

0,481

0,9

100

SIEMENS

3RV20110GA15

Esecuzione Fissa

MagnetoTermico

0,63/0,45 / 0,63

---/---/8

100 / N.C.

---

Quadripolare

2,02

---

---

---

---

---

---

Q21

L1L2L3N.QCT.0

L1L2L3.QCT.22

CBD.437.38.39.T

Utenza generica QCT C-22

QCT C-22

EXT.08

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

2,06

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K22

L1L2L3.QCT.21

QCT C-23

1,55

2,486

0,9

100

SIEMENS

3RV20111DA10

Esecuzione Fissa

MagnetoTermico

3,2/2,2 / 3,2

---/---/40

100 / N.C.

---

Quadripolare

1,42

---

---

---

---

---

---

Q23

L1L2L3N.QCT.0

L1L2L3.QCT.24

CBD.440.41.42.T

Utenza generica QCT C-24

QCT C-24

EP.01-A

1,55

2,486

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,64

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K24

L1L2L3.QCT.23

QCT C-25

1,55

2,486

0,9

100

SIEMENS

3RV20111DA10

Esecuzione Fissa

MagnetoTermico

3,2/2,2 / 2,5

---/---/40

100 / N.C.

---

Quadripolare

1,42

---

---

---

---

---

---

Q25

L1L2L3N.QCT.0

L1L2L3.QCT.26

CBD.443.44.45.T

Utenza generica QCT C-26

QCT C-26

EP.01-B

1,55

2,486

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,64

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K26

L1L2L3.QCT.25

A

QCT C-27

1,37

2,197

0,9

100

SIEMENS

3RV20111DA10

Esecuzione Fissa

MagnetoTermico

3,2/2,2 / 2,2

---/---/40

100 / N.C.

---

Quadripolare

1,4

---

---

---

---

---

---

Q27

L1L2L3N.QCT.0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18QCT

31 32

AL FG 32DAL FG 30

uni008031UNIVERSITÁ SAPIENZA

ROMA

QUADRO CENTRALE TERMICA

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAAB

L1L2L3.QCT.28

CBD.446.47.48.T

Utenza generica QCT C-28

QCT C-28

EP.02-A

1,37

2,197

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,59

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K28

L1L2L3.QCT.27

QCT C-29

1,37

2,197

0,9

100

SIEMENS

3RV20111DA10

Esecuzione Fissa

MagnetoTermico

3,2/2,2 / 3,2

---/---/40

100 / N.C.

---

Quadripolare

1,4

---

---

---

---

---

---

Q29

L1L2L3N.QCT.0

L1L2L3.QCT.30

CBD.449.50.51.T

Utenza generica QCT C-30

QCT C-30

EP.02-B

1,37

2,197

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,59

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K30

L1L2L3.QCT.29

QCT C-31

0,56

0,898

0,9

100

SIEMENS

3RV20110KA15

Esecuzione Fissa

MagnetoTermico

1,25/0,9 / 1,25

---/---/15

100 / N.C.

---

Quadripolare

1,61

---

---

---

---

---

---

Q31

L1L2L3N.QCT.0

L1L2L3.QCT.32

CBD.452.53.54.T

Utenza generica QCT C-32

QCT C-32

EP.03-A

0,56

0,898

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,68

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K32

L1L2L3.QCT.31

QCT C-33

0,56

0,898

0,9

100

SIEMENS

3RV20110KA15

Esecuzione Fissa

MagnetoTermico

1,25/0,9 / 1,25

---/---/15

100 / N.C.

---

Quadripolare

1,61

---

---

---

---

---

---

Q33

L1L2L3N.QCT.0

AB

L1L2L3.QCT.34

CBD.455.56.57.T

Utenza generica QCT C-34

QCT C-34

EP.03-B

0,56

0,898

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,68

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K34

L1L2L3.QCT.33

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18QCT

32 33

AL FG 33DAL FG 31

uni008032UNIVERSITÁ SAPIENZA

ROMA

QUADRO CENTRALE TERMICA

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAA

QCT C-35

0,3

0,481

0,9

100

SIEMENS

3RV20110KA15

Esecuzione Fissa

MagnetoTermico

1,25/0,9 / 1,25

---/---/15

100 / N.C.

---

Quadripolare

1,43

---

---

---

---

---

---

Q35

L1L2L3N.QCT.0

L1L2L3.QCT.36

CBD.458.59.60.T

Utenza generica QCT C-36

QCT C-36

EP.04-A

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,48

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K36

L1L2L3.QCT.35

QCT C-37

0,3

0,481

0,9

100

SIEMENS

3RV20110KA15

Esecuzione Fissa

MagnetoTermico

1,25/0,9 / 1,25

---/---/15

100 / N.C.

---

Quadripolare

1,43

---

---

---

---

---

---

Q37

L1L2L3N.QCT.0

L1L2L3.QCT.38

CBD.461.62.63.T

Utenza generica QCT C-38

QCT C-38

EP.04-B

0,3

0,481

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,48

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K38

L1L2L3.QCT.37

QCT C-39

2,06

3,304

0,9

100

SIEMENS

3RV20111EA10

Esecuzione Fissa

MagnetoTermico

4/2,8 / 4

---/---/48

100 / N.C.

---

Quadripolare

1,4

---

---

---

---

---

---

Q39

L1L2L3N.QCT.0

L1L2L3.QCT.40

CBD.464.65.66.T

Utenza generica QCT C-40

QCT C-40

EP.05-A

2,06

3,304

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,69

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K40

L1L2L3.QCT.39

A

QCT C-41

2,06

3,304

0,9

100

SIEMENS

3RV20111EA10

Esecuzione Fissa

MagnetoTermico

4/2,8 / 4

---/---/48

100 / N.C.

---

Quadripolare

1,4

---

---

---

---

---

---

Q41

L1L2L3N.QCT.0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

Sigla utenza

Descrizione

POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE

MARCAMODELLOESECUZIONETIPOLOGIA

PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]

DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO

SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]

23/0

1/20

18

IEE-02-18QCT

33 -

DAL FG 32

uni008033UNIVERSITÁ SAPIENZA

ROMA

QUADRO CENTRALE TERMICA

Schema Unifilare

Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAAB

L1L2L3.QCT.42

CBD.467.68.69.T

Utenza generica QCT C-42

QCT C-42

EP.05-B

2,06

3,304

0,9

100

SIEMENS

3RT20151AB01

Esecuzione Fissa

Contattore

---/--- / 7

---/---/---

--- /

---

Tripolare

1,69

FG16OM16

15

143/2M34A/30/0,38

0,380

1(4G1,5)

7,41

K42

L1L2L3.QCT.41

L3N.QCT.43

CBD.70.71.T

Utenza generica QCT C-43

QCT C-43

AUSILIARI

0,1

0,481

0,9

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

1,24

---

---

---

---

---

---

Q

Id

43

L3N.QCT.0

L3N.QCT.44

CBD.72.73.T

QCT C-44

RISERVA

0

0

---

100

SIEMENS

5SU13547KK16

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 16

---/---/160

10 / C

0,03 - Cl. A

Monofase L3+N

1,23

---

---

---

---

---

---

Q

Id

44

L3N.QCT.0

L1N.QCT.45

CBD.74.75.T

QCT C-45

RISERVA

0

0

---

100

SIEMENS

5SU13547KK10

Esecuzione Fissa

MagnetoTermicoDiff.

---/--- / 10

---/---/100

10 / C

0,03 - Cl. A

Monofase L1+N

1,23

---

---

---

---

---

---

Q

Id

45

L1N.QCT.0

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

1 2aux008001UNIVERSITÁ SAPIENZA

ROMA

SCHEMI AUSILIARI

Nelle pagine seguenti sono riportati gli schemi ausiliari deiquadri elettrici presenti nell'impianto

Progetto INTEGRA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

2 3aux002002UNIVERSITÁ SAPIENZA

ROMASchema AusiliariSEZIONE NORMALEQUADRO PT

RPP

S

10

QDPT/NOR. C-10ORDINARIA CORRIDOIO

E FILTRO

RPP

S

11

QDPT/NOR. C-11ORDINARIA

DISIMPEGNO

RPP

S

14

QDPT/NOR. C-14ORDINARIA

RPP

S

17

QDPT/NOR. C-17ORDINARIA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

3 4aux004003UNIVERSITÁ SAPIENZA

ROMASchema AusiliariSEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI

RPP

S

4

QLAP/NOR. C-4ORDINARIA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

4 - aux006004UNIVERSITÁ SAPIENZA

ROMASchema AusiliariSEZIONE NORMALEQUADRO P1

RPP

S

5

QDP1/NOR. C-5ORDINARIACORRIDOIO

RPP

S

6

QDP1/NOR. C-6ORDINARIA

DISIMPEGNO

RPP

S

9

QDP1/NOR. C-9ORDINARIAUFFICIO 1

RPP

S

13

QDP1/NOR. C-13ORDINARIARIUNIONI

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

1 2mor006001UNIVERSITÁ SAPIENZA

ROMA

MORSETTIERE

Nelle pagine seguenti sono riportati i disegni delle morsettieredi potenza dei Quadri

Progetto INTEGRA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18QGEN

2 3mor001002UNIVERSITÁ SAPIENZA

ROMASchema morsettiera

Quadro Generale EDIFICIO

L1.Q

GEN

.11

CBD.

70L2

.QG

EN.1

2CB

D.70

L3.Q

GEN

.13

CBD.

70N.

QG

EN.1

4CB

D.70

TCB

D.70

ALIM

ENTA

ZIO

NE O

RDIN

ARIA

QUA

DRO

PT

QG

EN C

-1FG

16M

16/H

07Z1

-K_2

PE

3(1

x50)

+(1x

25)+

(1PE

25)

L1.Q

GEN

.25

CBD.

35L2

.QG

EN.2

6CB

D.35

L3.Q

GEN

.27

CBD.

35N.

QG

EN.2

8CB

D.35

TCB

D.35

ALIM

ENTA

ZIO

NE Q

P1Q

GEN

C-2

FG16

OM

16

1(5G

25)

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

3 4mor002003UNIVERSITÁ SAPIENZA

ROMASchema morsettieraSEZIONE NORMALEQUADRO PT

L11

CBD.

70L2

2CB

D.70

L33

CBD.

70N

4CB

D.70

TCB

D.70

Da Q

uadr

o Q

GEN

- Pa

rtenz

a Q

GEN

C-1

QG

EN C

-1FG

16M

16/H

07Z1

-K_2

PE

3(1

x50)

+(1x

25)+

(1PE

25)

L1.Q

DPT/

NOR.

.35

CBD.

16L2

.QDP

T/NO

R..3

6CB

D.16

L3.Q

DPT/

NOR.

.37

CBD.

16N.

QDP

T/NO

R..3

8CB

D.16

TCB

D.16

ALIM

ENTA

ZIO

NE Q

LTQ

DPT/

NOR.

C-3

FG16

OM

16

1(5G

10)

L1.Q

DPT/

NOR.

.49

CBD.

25L2

.QDP

T/NO

R..4

10CB

D.25

L3.Q

DPT/

NOR.

.411

CBD.

25N.

QDP

T/NO

R..4

12CB

D.25

TCB

D.25

ALIM

ENTA

ZIO

NE Q

LAP

QDP

T/NO

R. C

-4FG

16O

M16

1(

5G16

)

L1.Q

DPT/

NOR.

.513

CBD.

16L2

.QDP

T/NO

R..5

14CB

D.16

L3.Q

DPT/

NOR.

.515

CBD.

16N.

QDP

T/NO

R..5

16CB

D.16

TCB

D.16

ALIM

ENTA

ZIO

NE U

PS P

IANO

TER

RAQ

DPT/

NOR.

C-5

FG16

OM

16

1(5G

10)

L1.Q

DPT/

NOR.

.617

CBD.

N.Q

DPT/

NOR.

.618

CBD.

TCB

D.

AUSI

LIAR

I Q

DPT/

NOR.

C-6

---

---

L3.Q

DPT/

NOR.

.719

CBD.

4N.

QDP

T/NO

R..7

20CB

D.4

TCB

D.4

BATT

ERIE

DI P

OST

QDP

T/NO

R. C

-7FG

16O

M16

1(

3G1,

5)

L1.Q

DPT/

NOR.

.821

CBD.

4N.

QDP

T/NO

R..8

22CB

D.4

TCB

D.4

ORD

INAR

IA D

EPO

SITO

QDP

T/NO

R. C

-9FG

16O

M16

1(

3G1,

5)

L1.Q

DPT/

NOR.

.823

CBD.

4N.

QDP

T/NO

R..8

24CB

D.4

TCB

D.4

ORD

INAR

IA C

ORR

IDO

IO E

FIL

TRO

QDP

T/NO

R. C

-10

FG16

OM

16

1(3G

1,5)

L1.Q

DPT/

NOR.

.825

CBD.

4N.

QDP

T/NO

R..8

26CB

D.4

TCB

D.4

ORD

INAR

IA D

ISIM

PEG

NOQ

DPT/

NOR.

C-1

1FG

16O

M16

1(

3G1,

5)

L1.Q

DPT/

NOR.

.827

CBD.

4N.

QDP

T/NO

R..8

28CB

D.4

TCB

D.4

EMER

GEN

ZA

QDP

T/NO

R. C

-12

FG16

OM

16

1(3G

1,5)

L1.Q

DPT/

NOR.

.13

29CB

D.4

N.Q

DPT/

NOR.

.13

30CB

D.4

TCB

D.4

ORD

INAR

IA

QDP

T/NO

R. C

-14

FG16

OM

16

1(3G

1,5)

L1.Q

DPT/

NOR.

.13

31CB

D.4

N.Q

DPT/

NOR.

.13

32CB

D.4

TCB

D.4

EMER

GEN

ZA

QDP

T/NO

R. C

-15

FG16

OM

16

1(3G

1,5)

L2.Q

DPT/

NOR.

.16

33CB

D.4

N.Q

DPT/

NOR.

.16

34CB

D.4

TCB

D.4

ORD

INAR

IA

QDP

T/NO

R. C

-17

FG16

OM

16

1(3G

1,5)

L2.Q

DPT/

NOR.

.16

35CB

D.4

N.Q

DPT/

NOR.

.16

36CB

D.4

TCB

D.4

EMER

GEN

ZA

QDP

T/NO

R. C

-18

FG16

OM

16

1(3G

1,5)

L3.Q

DPT/

NOR.

.19

37CB

D.4

N.Q

DPT/

NOR.

.19

38CB

D.4

TCB

D.4

PRES

E F

RIG

ORI

FERI

QDP

T/NO

R. C

-19

FG16

OM

16

1(3G

2,5)

L1.Q

DPT/

NOR.

.20

39CB

D.4

N.Q

DPT/

NOR.

.20

40CB

D.4

TCB

D.4

PRES

E DI

SER

VIZI

OQ

DPT/

NOR.

C-2

0FG

16O

M16

1(

3G2,

5)

L2.Q

DPT/

NOR.

.21

41CB

D.4

N.Q

DPT/

NOR.

.21

42CB

D.4

TCB

D.4

PRES

E SC

RIVA

NIA

1Q

DPT/

NOR.

C-2

1FG

16O

M16

1(

3G2,

5)

L3.Q

DPT/

NOR.

.22

43CB

D.4

N.Q

DPT/

NOR.

.22

44CB

D.4

TCB

D.4

PRES

E SC

RIVA

NIA

2Q

DPT/

NOR.

C-2

2FG

16O

M16

1(

3G2,

5)

L1.Q

DPT/

NOR.

.23

45CB

D.4

N.Q

DPT/

NOR.

.23

46CB

D.4

TCB

D.4

PRES

E SE

RVIZ

IO S

UPP.

PRO

CESS

IQ

DPT/

NOR.

C-2

3FG

16O

M16

1(

3G2,

5)

L2.Q

DPT/

NOR.

.24

47CB

D.4

N.Q

DPT/

NOR.

.24

48CB

D.4

TCB

D.4

RACK

DAT

IQ

DPT/

NOR.

C-2

4FG

16O

M16

1(

3G2,

5)

L3.Q

DPT/

NOR.

.25

49CB

D.N.

QDP

T/NO

R..2

550

CBD.

TCB

D.

RIS

ERVA

Q

DPT/

NOR.

C-2

5---

---

L1.Q

DPT/

NOR.

.26

51CB

D.N.

QDP

T/NO

R..2

652

CBD.

TCB

D.

RIS

ERVA

Q

DPT/

NOR.

C-2

6---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDPT/PR.

QDPT/PR.

4 5mor002004UNIVERSITÁ SAPIENZA

ROMASchema morsettieraSEZIONE PRIVILEGIATAQUADRO PT

L11

CBD.

6L2

2CB

D.6

L33

CBD.

6N

4CB

D.6

TCB

D.6

Da Q

uadr

o UP

S-PT

- Pa

rtenz

a UP

S-PT

C-3

UPS-

PT C

-3FG

16O

M16

1(

5G4)

L1.Q

DPT/

PR..3

5CB

D.4

N.Q

DPT/

PR..3

6CB

D.4

TCB

D.4

PRES

E SC

RIVA

NIA

1Q

DPT/

PR. C

-3FG

16O

M16

1(

3G2,

5)

L2.Q

DPT/

PR..4

7CB

D.4

N.Q

DPT/

PR..4

8CB

D.4

TCB

D.4

PRES

E SC

RIVA

NIA

2Q

DPT/

PR. C

-4FG

16O

M16

1(

3G2,

5)

L3.Q

DPT/

PR..5

9CB

D.N.

QDP

T/PR

..510

CBD.

TCB

D.

RIS

ERVA

Q

DPT/

PR. C

-5---

---

L1.Q

DPT/

PR..6

11CB

D.N.

QDP

T/PR

..612

CBD.

TCB

D.

RIS

ERVA

Q

DPT/

PR. C

-6---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

5 6mor003005UNIVERSITÁ SAPIENZA

ROMASchema morsettieraSEZIONE NORMALEQUADRO LABORATORIO TECNICO

L11

CBD.

16L2

2CB

D.16

L33

CBD.

16N

4CB

D.16

TCB

D.16

Da Q

uadr

o Q

DPT/

NOR.

- Pa

rtenz

a Q

DPT/

NOR.

C-3

QDP

T/NO

R. C

-3FG

16O

M16

1(

5G10

)

L1.Q

LT/N

OR.

.35

CBD.

4N.

QLT

/NO

R..3

6CB

D.4

TCB

D.4

ORD

INAR

IA

QLT

/NO

R. C

-4FG

16O

M16

1(

3G1,

5)

L1.Q

LT/N

OR.

.37

CBD.

4N.

QLT

/NO

R..3

8CB

D.4

TCB

D.4

EMER

GEN

ZA

QLT

/NO

R. C

-5FG

16O

M16

1(

3G1,

5)

L2.Q

LT/N

OR.

.69

CBD.

4N.

QLT

/NO

R..6

10CB

D.4

TCB

D.4

FRIG

O C

OM

BINA

TOQ

LT/N

OR.

C-6

FG16

OM

16

1(3G

2,5)

L3.Q

LT/N

OR.

.711

CBD.

4N.

QLT

/NO

R..7

12CB

D.4

TCB

D.4

ULTR

ACEN

TRIF

UGA

QLT

/NO

R. C

-7FG

16O

M16

1(

3G2,

5)

L1.Q

LT/N

OR.

.813

CBD.

4N.

QLT

/NO

R..8

14CB

D.4

TCB

D.4

AUTO

CLAV

E PI

CCO

LAQ

LT/N

OR.

C-8

FG16

OM

16

1(3G

2,5)

L2.Q

LT/N

OR.

.915

CBD.

4N.

QLT

/NO

R..9

16CB

D.4

TCB

D.4

INCU

B. P

IAST

REQ

LT/N

OR.

C-9

FG16

OM

16

1(3G

2,5)

L3.Q

LT/N

OR.

.10

17CB

D.4

N.Q

LT/N

OR.

.10

18CB

D.4

TCB

D.4

LIO

FILI

ZZAT

ORE

Q

LT/N

OR.

C-1

0FG

16O

M16

1(

3G2,

5)

L1.Q

LT/N

OR.

.11

19CB

D.4

N.Q

LT/N

OR.

.11

20CB

D.4

TCB

D.4

SIST

PUR

IFIC

. H2O

QLT

/NO

R. C

-11

FG16

OM

16

1(3G

2,5)

L2.Q

LT/N

OR.

.12

21CB

D.4

N.Q

LT/N

OR.

.12

22CB

D.4

TCB

D.4

CABI

NA A

FLU

SSO

LAM

INAR

EQ

LT/N

OR.

C-1

2FG

16O

M16

1(

3G2,

5)

L3.Q

LT/N

OR.

.13

23CB

D.4

N.Q

LT/N

OR.

.13

24CB

D.4

TCB

D.4

AUTO

CLAV

E G

RAND

EQ

LT/N

OR.

C-1

3FG

16O

M16

1(

3G2,

5)

L1.Q

LT/N

OR.

.14

25CB

D.4

N.Q

LT/N

OR.

.14

26CB

D.4

TCB

D.4

BANC

O 1

Q

LT/N

OR.

C-1

4FG

16O

M16

1(

3G2,

5)

L2.Q

LT/N

OR.

.15

27CB

D.4

N.Q

LT/N

OR.

.15

28CB

D.4

TCB

D.4

BANC

O 2

Q

LT/N

OR.

C-1

5FG

16O

M16

1(

3G2,

5)

L3.Q

LT/N

OR.

.16

29CB

D.4

N.Q

LT/N

OR.

.16

30CB

D.4

TCB

D.4

BANC

O 3

Q

LT/N

OR.

C-1

6FG

16O

M16

1(

3G2,

5)

L1.Q

LT/N

OR.

.17

31CB

D.10

L2.Q

LT/N

OR.

.17

32CB

D.10

L3.Q

LT/N

OR.

.17

33CB

D.10

N.Q

LT/N

OR.

.17

34CB

D.10

TCB

D.10

LAVA

VETR

ERIA

Q

LT/N

OR.

C-1

7FG

16O

M16

1(

5G6)

L3.Q

LT/N

OR.

.18

35CB

D.4

N.Q

LT/N

OR.

.18

36CB

D.4

TCB

D.4

PRES

E DI

SER

VIZI

OQ

LT/N

OR.

C-1

8FG

16O

M16

1(

3G2,

5)

L1.Q

LT/N

OR.

.19

37CB

D.N.

QLT

/NO

R..1

938

CBD.

TCB

D.

RIS

ERVA

Q

LT/N

OR.

C-1

9---

---

L2.Q

LT/N

OR.

.20

39CB

D.N.

QLT

/NO

R..2

040

CBD.

TCB

D.

RIS

ERVA

Q

LT/N

OR.

C-2

0---

---

L3.Q

LT/N

OR.

.21

41CB

D.N.

QLT

/NO

R..2

142

CBD.

TCB

D.

RIS

ERVA

Q

LT/N

OR.

C-2

1---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/PR

QLT/PR

6 7mor003006UNIVERSITÁ SAPIENZA

ROMASchema morsettieraSEZIONE PRIVILEGIATAQUADRO LABORATORIO TECNICO

L11

CBD.

6L2

2CB

D.6

L33

CBD.

6N

4CB

D.6

TCB

D.6

Da Q

uadr

o UP

S-PT

- Pa

rtenz

a UP

S-PT

C-1

UPS-

PT C

-1FG

16O

M16

1(

5G4)

L1.Q

LT/P

R.3

5CB

D.4

N.Q

LT/P

R.3

6CB

D.4

TCB

D.4

BANC

O 1

Q

LT/P

R C-

3FG

16O

M16

1(

3G2,

5)

L2.Q

LT/P

R.4

7CB

D.4

N.Q

LT/P

R.4

8CB

D.4

TCB

D.4

BANC

O 2

Q

LT/P

R C-

4FG

16O

M16

1(

3G2,

5)

L3.Q

LT/P

R.5

9CB

D.4

N.Q

LT/P

R.5

10CB

D.4

TCB

D.4

BANC

O 3

Q

LT/P

R C-

5FG

16O

M16

1(

3G2,

5)

L1.Q

LT/P

R.6

11CB

D.N.

QLT

/PR.

612

CBD.

TCB

D.

RIS

ERVA

Q

LT/P

R C-

6---

---

L2.Q

LT/P

R.7

13CB

D.N.

QLT

/PR.

714

CBD.

TCB

D.

RIS

ERVA

Q

LT/P

R C-

7---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

7 8mor004007UNIVERSITÁ SAPIENZA

ROMASchema morsettieraSEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI

L11

CBD.

25L2

2CB

D.25

L33

CBD.

25N

4CB

D.25

TCB

D.25

Da Q

uadr

o Q

DPT/

NOR.

- Pa

rtenz

a Q

DPT/

NOR.

C-4

QDP

T/NO

R. C

-4FG

16O

M16

1(

5G16

)

L1.Q

LAP/

NOR.

.35

CBD.

4N.

QLA

P/NO

R..3

6CB

D.4

TCB

D.4

ORD

INAR

IA

QLA

P/NO

R. C

-4FG

16O

M16

1(

3G1,

5)

L1.Q

LAP/

NOR.

.37

CBD.

4N.

QLA

P/NO

R..3

8CB

D.4

TCB

D.4

EMER

GEN

ZA

QLA

P/NO

R. C

-5FG

16O

M16

1(

3G1,

5)

L2.Q

LAP/

NOR.

.69

CBD.

4N.

QLA

P/NO

R..6

10CB

D.4

TCB

D.4

BANC

O 1

Q

LAP/

NOR.

C-6

FG16

OM

16

1(3G

2,5)

L3.Q

LAP/

NOR.

.711

CBD.

4N.

QLA

P/NO

R..7

12CB

D.4

TCB

D.4

BANC

O 2

Q

LAP/

NOR.

C-7

FG16

OM

16

1(3G

2,5)

L1.Q

LAP/

NOR.

.813

CBD.

4N.

QLA

P/NO

R..8

14CB

D.4

TCB

D.4

BANC

O 3

Q

LAP/

NOR.

C-8

FG16

OM

16

1(3G

2,5)

L2.Q

LAP/

NOR.

.915

CBD.

4N.

QLA

P/NO

R..9

16CB

D.4

TCB

D.4

BANC

O 4

Q

LAP/

NOR.

C-9

FG16

OM

16

1(3G

2,5)

L3.Q

LAP/

NOR.

.10

17CB

D.4

N.Q

LAP/

NOR.

.10

18CB

D.4

TCB

D.4

BANC

O 5

Q

LAP/

NOR.

C-1

0FG

16O

M16

1(

3G2,

5)

L1.Q

LAP/

NOR.

.11

19CB

D.4

N.Q

LAP/

NOR.

.11

20CB

D.4

TCB

D.4

PRES

E DI

SER

VIZI

OQ

LAP/

NOR.

C-1

1FG

16O

M16

1(

3G2,

5)

L2.Q

LAP/

NOR.

.12

21CB

D.N.

QLA

P/NO

R..1

222

CBD.

TCB

D.

AUSI

LIAR

I Q

LAP/

NOR.

C-1

2---

---

L3.Q

LAP/

NOR.

.13

23CB

D.N.

QLA

P/NO

R..1

324

CBD.

TCB

D.

RIS

ERVA

Q

LAP/

NOR.

C-1

3---

---

L1.Q

LAP/

NOR.

.14

25CB

D.N.

QLA

P/NO

R..1

426

CBD.

TCB

D.

RIS

ERVA

Q

LAP/

NOR.

C-1

4---

---

L2.Q

LAP/

NOR.

.15

27CB

D.N.

QLA

P/NO

R..1

528

CBD.

TCB

D.

RIS

ERVA

Q

LAP/

NOR.

C-1

5---

---

L3.Q

LAP/

NOR.

.16

29CB

D.N.

QLA

P/NO

R..1

630

CBD.

TCB

D.

RIS

ERVA

Q

LAP/

NOR.

C-1

6---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/PR.

QLAP.PR

8 9mor004008UNIVERSITÁ SAPIENZA

ROMASchema morsettieraSEZIONE PRIVILEGIATAQUADRO LABORATORIO AREA PROCESSI

L11

CBD.

10L2

2CB

D.10

L33

CBD.

10N

4CB

D.10

TCB

D.10

Da Q

uadr

o UP

S-PT

- Pa

rtenz

a UP

S-PT

C-2

UPS-

PT C

-2FG

16O

M16

1(

5G6)

L1.Q

LAP.

PR.3

5CB

D.4

N.Q

LAP.

PR.3

6CB

D.4

TCB

D.4

BANC

O 1

Q

LAP.

PR C

-3FG

16O

M16

1(

3G2,

5)

L2.Q

LAP.

PR.4

7CB

D.4

N.Q

LAP.

PR.4

8CB

D.4

TCB

D.4

BANC

O 2

Q

LAP.

PR C

-4FG

16O

M16

1(

3G2,

5)

L3.Q

LAP.

PR.5

9CB

D.4

N.Q

LAP.

PR.5

10CB

D.4

TCB

D.4

BANC

O 3

Q

LAP.

PR C

-5FG

16O

M16

1(

3G2,

5)

L1.Q

LAP.

PR.6

11CB

D.4

N.Q

LAP.

PR.6

12CB

D.4

TCB

D.4

BANC

O 4

Q

LAP.

PR C

-6FG

16O

M16

1(

3G2,

5)

L2.Q

LAP.

PR.7

13CB

D.4

N.Q

LAP.

PR.7

14CB

D.4

TCB

D.4

BANC

O 5

Q

LAP.

PR C

-7FG

16O

M16

1(

3G2,

5)

L3.Q

LAP.

PR.8

15CB

D.N.

QLA

P.PR

.816

CBD.

TCB

D.

RIS

ERVA

Q

LAP.

PR C

-8---

---

L1.Q

LAP.

PR.9

17CB

D.N.

QLA

P.PR

.918

CBD.

TCB

D.

RIS

ERVA

Q

LAP.

PR C

-9---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: UPS ESCLUSO DALLA FORNITURA E POSA IN OPERA

23/0

1/20

18

IEE-02-18

UPS-PT

UPS-PT

9 10mor005009UNIVERSITÁ SAPIENZA

ROMASchema morsettiera

UPS-PT

1CB

D.16

2CB

D.16

3CB

D.16

4CB

D.16

TCB

D.16

Da Q

uadr

o Q

DPT/

NOR.

- Pa

rtenz

a Q

DPT/

NOR.

C-5

QDP

T/NO

R. C

-5FG

16O

M16

1(

5G10

)

L1.U

PS-P

T.1

5CB

D.6

L2.U

PS-P

T.1

6CB

D.6

L3.U

PS-P

T.1

7CB

D.6

N.UP

S-PT

.18

CBD.

6T

CBD.

6

ALIM

. SEZ

. PRI

VILE

GIA

TA Q

LTUP

S-PT

C-1

FG16

OM

16

1(5G

4)

L1.U

PS-P

T.2

9CB

D.10

L2.U

PS-P

T.2

10CB

D.10

L3.U

PS-P

T.2

11CB

D.10

N.UP

S-PT

.212

CBD.

10T

CBD.

10

ALIM

ENTA

Z. S

EZ. P

RIV.

QLA

PUP

S-PT

C-2

FG16

OM

16

1(5G

6)

L1.U

PS-P

T.3

13CB

D.6

L2.U

PS-P

T.3

14CB

D.6

L3.U

PS-P

T.3

15CB

D.6

N.UP

S-PT

.316

CBD.

6T

CBD.

6

ALIM

ENTA

ZIO

NE S

EZ. P

RIV.

QDP

TUP

S-PT

C-3

FG16

OM

16

1(5G

4)

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

10 11mor006010UNIVERSITÁ SAPIENZA

ROMASchema morsettieraSEZIONE NORMALEQUADRO P1

L11

CBD.

35L2

2CB

D.35

L33

CBD.

35N

4CB

D.35

TCB

D.35

Da Q

uadr

o Q

GEN

- Pa

rtenz

a Q

GEN

C-2

QG

EN C

-2FG

16O

M16

1(

5G25

)

L1.Q

DP1/

NOR.

.35

CBD.

6L2

.QDP

1/NO

R..3

6CB

D.6

L3.Q

DP1/

NOR.

.37

CBD.

6N.

QDP

1/NO

R..3

8CB

D.6

TCB

D.6

ALIM

ENTA

ZIO

NE U

PS P

IANO

1Q

DP1/

NOR.

C-3

FG16

OM

16

1(5G

4)

L3.Q

DP1/

NOR.

.49

CBD.

4N.

QDP

1/NO

R..4

10CB

D.4

TCB

D.4

ORD

INAR

IA C

ORR

IDO

IOQ

DP1/

NOR.

C-5

FG16

OM

16

1(3G

1,5)

L3.Q

DP1/

NOR.

.411

CBD.

4N.

QDP

1/NO

R..4

12CB

D.4

TCB

D.4

ORD

INAR

IA D

ISIM

PEG

NOQ

DP1/

NOR.

C-6

FG16

OM

16

1(3G

1,5)

L3.Q

DP1/

NOR.

.413

CBD.

4N.

QDP

1/NO

R..4

14CB

D.4

TCB

D.4

EMER

GEN

ZA

QDP

1/NO

R. C

-7FG

16O

M16

1(

3G1,

5)

L1.Q

DP1/

NOR.

.815

CBD.

4N.

QDP

1/NO

R..8

16CB

D.4

TCB

D.4

ORD

INAR

IA U

FFIC

IO 1

QDP

1/NO

R. C

-9FG

16O

M16

1(

3G1,

5)

L1.Q

DP1/

NOR.

.817

CBD.

4N.

QDP

1/NO

R..8

18CB

D.4

TCB

D.4

ORD

INAR

IA U

FF.2

E I

NFO

RMAT

ICA

QDP

1/NO

R. C

-10

FG16

OM

16

1(3G

1,5)

L1.Q

DP1/

NOR.

.819

CBD.

4N.

QDP

1/NO

R..8

20CB

D.4

TCB

D.4

EMER

GEN

ZA

QDP

1/NO

R. C

-11

FG16

OM

16

1(3G

1,5)

L3.Q

DP1/

NOR.

.12

21CB

D.4

N.Q

DP1/

NOR.

.12

22CB

D.4

TCB

D.4

ORD

INAR

IA R

IUNI

ONI

QDP

1/NO

R. C

-13

FG16

OM

16

1(3G

1,5)

L3.Q

DP1/

NOR.

.12

23CB

D.4

N.Q

DP1/

NOR.

.12

24CB

D.4

TCB

D.4

ORD

INAR

IA S

UPPO

RTO

TEC

NICO

QDP

1/NO

R. C

-14

FG16

OM

16

1(3G

1,5)

L3.Q

DP1/

NOR.

.12

25CB

D.4

N.Q

DP1/

NOR.

.12

26CB

D.4

TCB

D.4

EMER

GEN

ZA

QDP

1/NO

R. C

-15

FG16

OM

16

1(3G

1,5)

L1.Q

DP1/

NOR.

.16

27CB

D.4

N.Q

DP1/

NOR.

.16

28CB

D.4

TCB

D.4

FM F

AN C

OIL

REC

UPER

ATO

REQ

DP1/

NOR.

C-1

6FG

16O

M16

1(

3G2,

5)

L2.Q

DP1/

NOR.

.17

29CB

D.4

N.Q

DP1/

NOR.

.17

30CB

D.4

TCB

D.4

RACK

DAT

IQ

DP1/

NOR.

C-1

7FG

16O

M16

1(

3G2,

5)

L3.Q

DP1/

NOR.

.18

31CB

D.4

N.Q

DP1/

NOR.

.18

32CB

D.4

TCB

D.4

PRES

E DI

SER

VIZI

OQ

DP1/

NOR.

C-1

8FG

16O

M16

1(

3G2,

5)

L1.Q

DP1/

NOR.

.19

33CB

D.4

N.Q

DP1/

NOR.

.19

34CB

D.4

TCB

D.4

FM IN

FORM

ATIC

A E

UFFI

CIQ

DP1/

NOR.

C-1

9FG

16O

M16

1(

3G2,

5)

L2.Q

DP1/

NOR.

.20

35CB

D.4

N.Q

DP1/

NOR.

.20

36CB

D.4

TCB

D.4

FM R

IUNI

ONI

E S

UPP.

TEC

NICO

QDP

1/NO

R. C

-20

FG16

OM

16

1(3G

2,5)

L3.Q

DP1/

NOR.

.21

37CB

D.N.

QDP

1/NO

R..2

138

CBD.

TCB

D.

RIS

ERVA

Q

DP1/

NOR.

C-2

1---

---

L1.Q

DP1/

NOR.

.22

39CB

D.N.

QDP

1/NO

R..2

240

CBD.

TCB

D.

RIS

ERVA

Q

DP1/

NOR.

C-2

2---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/PR.

QDP1/PR.

11 12mor006011UNIVERSITÁ SAPIENZA

ROMASchema morsettieraSEZIONE PRIVILEGIATAQUADRO P1

L11

CBD.

6L2

2CB

D.6

L33

CBD.

6N

4CB

D.6

TCB

D.6

Da Q

uadr

o UP

S-P1

- Pa

rtenz

a UP

S-P1

C-1

UPS-

P1 C

-1FG

16O

M16

1(

5G4)

L1.Q

DP1/

PR..3

5CB

D.4

N.Q

DP1/

PR..3

6CB

D.4

TCB

D.4

FM IN

FORM

ATIC

A E

UFFI

CIQ

DP1/

PR. C

-3FG

16O

M16

1(

3G2,

5)

L2.Q

DP1/

PR..4

7CB

D.4

N.Q

DP1/

PR..4

8CB

D.4

TCB

D.4

FM IN

FORM

ATIC

A E

UFFI

CIQ

DP1/

PR. C

-4FG

16O

M16

1(

3G2,

5)

L3.Q

DP1/

PR..5

9CB

D.4

N.Q

DP1/

PR..5

10CB

D.4

TCB

D.4

FM U

FFIC

IO 1

QDP

1/PR

. C-5

FG16

OM

16

1(3G

2,5)

L1.Q

DP1/

PR..6

11CB

D.4

N.Q

DP1/

PR..6

12CB

D.4

TCB

D.4

FM U

FFIC

IO 2

QDP

1/PR

. C-6

FG16

OM

16

1(3G

2,5)

L2.Q

DP1/

PR..7

13CB

D.4

N.Q

DP1/

PR..7

14CB

D.4

TCB

D.4

FM S

UPPO

RTO

TEC

NICO

QDP

1/PR

. C-7

FG16

OM

16

1(3G

2,5)

L3.Q

DP1/

PR..8

15CB

D.N.

QDP

1/PR

..816

CBD.

TCB

D.

RIS

ERVA

Q

DP1/

PR. C

-8---

---

L1.Q

DP1/

PR..9

17CB

D.N.

QDP

1/PR

..918

CBD.

TCB

D.

RIS

ERVA

Q

DP1/

PR. C

-9---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: FORNITURA E POSA IN OPERA UPS ESCLUSA DAL'APPALTO

23/0

1/20

18

IEE-02-18

UPS-P1

UPS-P1

12 13mor007012UNIVERSITÁ SAPIENZA

ROMASchema morsettiera

UPS P1

1CB

D.6

2CB

D.6

3CB

D.6

4CB

D.6

TCB

D.6

Da Q

uadr

o Q

DP1/

NOR.

- Pa

rtenz

a Q

DP1/

NOR.

C-3

QDP

1/NO

R. C

-3FG

16O

M16

1(

5G4)

L1.U

PS-P

1.1

5CB

D.6

L2.U

PS-P

1.1

6CB

D.6

L3.U

PS-P

1.1

7CB

D.6

N.UP

S-P1

.18

CBD.

6T

CBD.

6

UP

S-P1

C-1

FG16

OM

16

1(5G

4)

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

13 14mor008013UNIVERSITÁ SAPIENZA

ROMASchema morsettiera

QUADRO CENTRALE TERMICA

L1.Q

CT.2

1CB

D.L2

.QCT

.22

CBD.

L3.Q

CT.2

3CB

D.N

.QCT

.24

CBD.

TCB

D.

Q

CT C

-2---

---

L1.Q

CT.3

5CB

D.50

L2.Q

CT.3

6CB

D.50

L3.Q

CT.3

7CB

D.50

N.Q

CT.3

8CB

D.50

TCB

D.50

GRU

PPO

FRI

GO

QCT

C-3

FG16

M16

/H07

Z1-K

_2 P

E 4

(1x3

5)+(

1PE3

5)

L1.Q

CT.4

9CB

D.35

L2.Q

CT.4

10CB

D.35

L3.Q

CT.4

11CB

D.35

N.Q

CT.4

12CB

D.35

TCB

D.35

UTA

1

QCT

C-4

FG16

M16

/H07

Z1-K

_2 P

E 3

(1x2

5)+(

1x16

)+(1

PE16

)

L1.Q

CT.6

13CB

D.4

L2.Q

CT.6

14CB

D.4

L3.Q

CT.6

15CB

D.4

TCB

D.4

EXT.

02

QCT

C-6

FG16

OM

16

1(4G

1,5)

L1.Q

CT.8

16CB

D.4

L2.Q

CT.8

17CB

D.4

L3.Q

CT.8

18CB

D.4

TCB

D.4

EXT.

02

QCT

C-8

FG16

OM

16

1(4G

1,5)

L1.Q

CT.1

019

CBD.

4L2

.QCT

.10

20CB

D.4

L3.Q

CT.1

021

CBD.

4T

CBD.

4

EXT.

02

QCT

C-1

0FG

16O

M16

1(

4G1,

5)

L1.Q

CT.1

222

CBD.

4L2

.QCT

.12

23CB

D.4

L3.Q

CT.1

224

CBD.

4T

CBD.

4

EXT.

03

QCT

C-1

2FG

16O

M16

1(

4G1,

5)

L1.Q

CT.1

425

CBD.

4L2

.QCT

.14

26CB

D.4

L3.Q

CT.1

427

CBD.

4T

CBD.

4

EXT.

04

QCT

C-1

4FG

16O

M16

1(

4G1,

5)

L1.Q

CT.1

628

CBD.

4L2

.QCT

.16

29CB

D.4

L3.Q

CT.1

630

CBD.

4T

CBD.

4

EXT.

05

QCT

C-1

6FG

16O

M16

1(

4G1,

5)

L1.Q

CT.1

831

CBD.

4L2

.QCT

.18

32CB

D.4

L3.Q

CT.1

833

CBD.

4T

CBD.

4

EXT.

06

QCT

C-1

8FG

16O

M16

1(

4G1,

5)

L1.Q

CT.2

034

CBD.

4L2

.QCT

.20

35CB

D.4

L3.Q

CT.2

036

CBD.

4T

CBD.

4

EXT.

07

QCT

C-2

0FG

16O

M16

1(

4G1,

5)

L1.Q

CT.2

237

CBD.

4L2

.QCT

.22

38CB

D.4

L3.Q

CT.2

239

CBD.

4T

CBD.

4

EXT.

08

QCT

C-2

2FG

16O

M16

1(

4G1,

5)

L1.Q

CT.2

440

CBD.

4L2

.QCT

.24

41CB

D.4

L3.Q

CT.2

442

CBD.

4T

CBD.

4

EP.0

1-A

QCT

C-2

4FG

16O

M16

1(

4G1,

5)

L1.Q

CT.2

643

CBD.

4L2

.QCT

.26

44CB

D.4

L3.Q

CT.2

645

CBD.

4T

CBD.

4

EP.0

1-B

QCT

C-2

6FG

16O

M16

1(

4G1,

5)

L1.Q

CT.2

846

CBD.

4L2

.QCT

.28

47CB

D.4

L3.Q

CT.2

848

CBD.

4T

CBD.

4

EP.0

2-A

QCT

C-2

8FG

16O

M16

1(

4G1,

5)

L1.Q

CT.3

049

CBD.

4L2

.QCT

.30

50CB

D.4

L3.Q

CT.3

051

CBD.

4T

CBD.

4

EP.0

2-B

QCT

C-3

0FG

16O

M16

1(

4G1,

5)

L1.Q

CT.3

252

CBD.

4L2

.QCT

.32

53CB

D.4

L3.Q

CT.3

254

CBD.

4T

CBD.

4

EP.0

3-A

QCT

C-3

2FG

16O

M16

1(

4G1,

5)

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

14 - mor008014UNIVERSITÁ SAPIENZA

ROMASchema morsettiera

QUADRO CENTRALE TERMICA

L1.Q

CT.3

455

CBD.

4L2

.QCT

.34

56CB

D.4

L3.Q

CT.3

457

CBD.

4T

CBD.

4

EP.0

3-B

QCT

C-3

4FG

16O

M16

1(

4G1,

5)

L1.Q

CT.3

658

CBD.

4L2

.QCT

.36

59CB

D.4

L3.Q

CT.3

660

CBD.

4T

CBD.

4

EP.0

4-A

QCT

C-3

6FG

16O

M16

1(

4G1,

5)

L1.Q

CT.3

861

CBD.

4L2

.QCT

.38

62CB

D.4

L3.Q

CT.3

863

CBD.

4T

CBD.

4

EP.0

4-B

QCT

C-3

8FG

16O

M16

1(

4G1,

5)

L1.Q

CT.4

064

CBD.

4L2

.QCT

.40

65CB

D.4

L3.Q

CT.4

066

CBD.

4T

CBD.

4

EP.0

5-A

QCT

C-4

0FG

16O

M16

1(

4G1,

5)

L1.Q

CT.4

267

CBD.

4L2

.QCT

.42

68CB

D.4

L3.Q

CT.4

269

CBD.

4T

CBD.

4

EP.0

5-B

QCT

C-4

2FG

16O

M16

1(

4G1,

5)

L3.Q

CT.4

370

CBD.

N.Q

CT.4

371

CBD.

TCB

D.

AUSI

LIAR

I Q

CT C

-43

---

---

L3.Q

CT.4

472

CBD.

N.Q

CT.4

473

CBD.

TCB

D.

RIS

ERVA

Q

CT C

-44

---

---

L1.Q

CT.4

574

CBD.

N.Q

CT.4

575

CBD.

TCB

D.

RIS

ERVA

Q

CT C

-45

---

---

MO

RS

ETT

ON

.TI

PO

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

1 2ver000001UNIVERSITÁ SAPIENZA

ROMA

CONDUTTURE - PROTEZIONIVERIFICA DEL COORDINAMENTO

Nelle tabelle riportate nei fogli seguenti sono riassunti i datiriguardanti le verifiche del coordinamento condutture -dispositivi di protezione, secondo quanto indicato di seguito:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(11)

(10)

(12)

DESCRIZIONEdella parte di impianto alimentata

DATI DELLA CONDUTTURA

formazioneLunghezza e lunghezza massima protettaCaduta di tensione % con la corrente di caricoIb e con la corrente nominale del dispositivo diprotezione a monte

DATI DELL'APPARECCHIATURA DIPROTEZIONE

MarcaModelloPolarita'

Corrente nominale su fase e neutroCorrente differenziale nominale (doveapplicabile)

PROTEZIONE CONTRO I CONTATTIINDIRETTI

Corrente di intervento del dispositivoCorrente di guasto a terra

PROTEZIONE CONTRO IL CORTOCIRCUITO

Potere di interruzione del dispositivo diprotezione (dove applicabile)Corrente di cortocircuito massima nel punto diinstallazione

Conduttore di fase

Conduttore di neutro

Conduttore di protezione (PE)

I t <= K S (Rif. CEI 64.8/4 Art. 434.3)2 2 2

Conduttore di fase

Conduttore di faseConduttore di neutro

Conduttore di neutro

PROTEZIONE CONTRO IL SOVRACCARICO

Ib <= In <= Iz (Rif. CEI 64.8 Art. 433.2)

If <= 1.45 Iz (Rif. CEI 64.8 Art. 433.2)

TEST RIASSUNTIVO

Protezione contro i cortocircuitiProtezione contro i sovraccarichiMassima caduta di tensione nell'impiantoMassima lunghezza delle linee di alimentazione

Esito positivo Esito negativo

Progetto INTEGRA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

2 3ver000002UNIVERSITÁ SAPIENZA

ROMA

5s

V

BCK

BCK

CONDUTTURE - PROTEZIONIVERIFICA DEL COORDINAMENTO

Valore relativo ad una condizionedi verifica con esito positivo

Valore relativo ad una condizionedi verifica con esito negativo

Valore non presente (datoincompleto)

Valore non significativo nellaconfigurazione scelta

235.2

235.2

- - -

Protezione contro i contattiindiretti realizzata con tempo diintervento di 5 secondi

Protezione contro i contattiindiretti realizzata mediantedoppio isolamento

Protezione contro i sovraccarichirealizzata dal dispositivo a valle

Richiesta la modalità diprotezione in backup per ildispositivo di protezione

Realizzata la modalità diprotezione in backup per ildispositivo di protezione

Progetto INTEGRA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18QGEN

3 4ver001003UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

Quadro Generale EDIFICIO

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QGEN C-0---

--- ---

0,65 0,89

SIEMENS

VL400.LI.TM

Quadripolare

55315 315

--- 12,26

3 780

6 006

---

---

---

---

---

---

306

315 315

--- ---

378

---

378

---

QGEN C-1

ALIMENTAZIONE ORDINARIA QUADRO PT

3(1x50)+(1x25)+(1PE25)

20 67

1,03 1,31

SIEMENS

3VA11 L/T TM220 ATFM 3RN/2

Quadripolare

25100 50

--- 12,16

1 500

3 259

1,91E+5

5,11E+7

1,6E+5

1,28E+7

1,6E+5

1,28E+7

93

100 50

123 82

130

178

65

119

QGEN C-2

ALIMENTAZIONE QP1

1(5G25)

15 112

0,9 1,28

SIEMENS

3VA10 L/T TM210 FTFM 3R

Quadripolare

1663 63

--- 12,16

756

3 220

1,29E+5

1,28E+7

9,88E+4

1,28E+7

9,92E+4

1,28E+7

42

63 63

74 74

82

107

82

107

QGEN C-3

ALIMENTAZIONE QCT

3(1x95)+(1x50)+(1PE50)

30 66

1,23 1,58

SIEMENS

3VA12 L/T TM240 ATAM 3RN/2

Quadripolare

36200 100

--- 12,16

2 400

3 608

1,91E+5

1,85E+8

1,6E+5

5,11E+7

1,6E+5

5,11E+7

171

200 100

269 175

260

390

130

254

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

4 5ver002004UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO PT

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDPT/NOR. C-0

GENERALE SEZ.NORMALE

---

--- ---

1,04 1,31

SIEMENS

3KA71164AA00

Quadripolare

---100 50

--- 9,27

1 500

3 255

---

---

---

---

---

---

93

100 50

--- ---

130

---

65

---

QDPT/NOR. C-1

SPD

---

--- ---

1,04 1,31

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

25100 50

--- 9,26

1 500

3 255

---

---

---

---

---

---

0

100 50

--- ---

130

---

65

---

QDPT/NOR. C-2

PRESENZA RETE

---

--- ---

1,04 1,74

SIEMENS

3NW6 Gr. 10x38 Ridotto

Tripolare

1002 2

--- 9,26

13

248

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QDPT/NOR. C-3

ALIMENTAZIONE QLT

1(5G10)

15 93

1,54 2,06

SIEMENS

5SL44507+5SM26468

Quadripolare

1050 50

0,3 9,26

0,3

1 436

1,11E+5

2,04E+6

4,52E+4

2,04E+6

4,75E+4

2,04E+6

36

50 50

54 54

65

78

65

78

QDPT/NOR. C-4

ALIMENTAZIONE QLAP

1(5G16)

15 177

1,31 1,92

SIEMENS

5SL44637+5SM26468

Quadripolare

1063 63

0,3 9,26

0,3

1 800

1,12E+5

5,23E+6

4,54E+4

5,23E+6

4,76E+4

5,23E+6

32

63 63

72 72

82

104

82

104

QDPT/NOR. C-5

ALIMENTAZIONE UPSPIANO TERRA

1(5G10)

15 86

1,59 2,14

SIEMENS

5SY64507+5SM26458

Quadripolare

1050 50

0,3 9,26

0,3

1 424

6,62E+4

2,04E+6

2,69E+4

2,04E+6

2,87E+4

2,04E+6

36

50 50

54 54

65

78

65

78

QDPT/NOR. C-6

AUSILIARI

---

--- ---

1,06 1,41

SIEMENS

5SU13537KK10

Monofase

1510 10

0,03 4,58

0,03

2 557

---

---

---

---

---

---

2,406

10 10

--- ---

13

---

13

---

QDPT/NOR. C-7

BATTERIEDI POST

1(3G1,5)

25 36

3,12 4,28

SIEMENS

5SU13537KK10

Monofase

1510 10

0,03 4,58

0,03

204

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

7,217

10 10

19 19

13

27

13

27

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

5 6ver002005UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO PT

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDPT/NOR. C-8

GENERALE ILLUMINAZIONECORRIDOIO

---

--- ---

1,12 1,41

SIEMENS

5SU13537KK10

Monofase

11,2510 10

0,03 4,58

0,03

2 557

---

---

---

---

---

---

7,698

10 10

--- ---

13

---

13

---

QDPT/NOR. C-9

ORDINARIADEPOSITO

1(3G1,5)

7 111

1,3 2,22

---

------10 10

--- 3,75

0,03

610

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

2,406

10 10

19 19

13

27

13

27

QDPT/NOR. C-10

ORDINARIA CORRIDOIOE FILTRO

1(3G1,5)

25 111

1,77 4,28

---

------10 10

--- 3,75

0,03

204

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

2,406

10 10

19 19

13

27

13

27

QDPT/NOR. C-11

ORDINARIADISIMPEGNO

1(3G1,5)

25 111

1,77 4,28

---

------10 10

--- 3,75

0,03

204

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

2,406

10 10

19 19

13

27

13

27

QDPT/NOR. C-12

EMERGENZA

1(3G1,5)

25 556

1,25 4,28

---

------10 10

--- 3,75

0,03

204

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

0,481

10 10

19 19

13

27

13

27

QDPT/NOR. C-13

GENERALE ILLUMINAZIONEAREA PROCESSI

---

--- ---

1,07 1,41

SIEMENS

5SU13537KK10

Monofase

11,2510 10

0,03 4,58

0,03

2 557

---

---

---

---

---

---

2,887

10 10

--- ---

13

---

13

---

QDPT/NOR. C-14

ORDINARIA

1(3G1,5)

15 113

1,46 3,14

---

------10 10

--- 3,75

0,03

324

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

2,406

10 10

19 19

13

27

13

27

QDPT/NOR. C-15

EMERGENZA

1(3G1,5)

15 566

1,14 3,14

---

------10 10

--- 3,75

0,03

324

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

0,481

10 10

19 19

13

27

13

27

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

6 7ver002006UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO PT

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDPT/NOR. C-16

GENERALE ILLUMINAZIONEDIDATTICA

---

--- ---

1,07 1,41

SIEMENS

5SU13537KK10

Monofase

11,2510 10

0,03 4,58

0,03

2 557

---

---

---

---

---

---

2,887

10 10

--- ---

13

---

13

---

QDPT/NOR. C-17

ORDINARIA

1(3G1,5)

20 113

1,59 3,71

---

------10 10

--- 3,75

0,03

250

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

2,406

10 10

19 19

13

27

13

27

QDPT/NOR. C-18

EMERGENZA

1(3G1,5)

20 566

1,17 3,71

---

------10 10

--- 3,75

0,03

250

9,05E+3

4,6E+4

8,87E+3

4,6E+4

9,05E+3

4,6E+4

0,481

10 10

19 19

13

27

13

27

QDPT/NOR. C-19

PRESE FRIGORIFERI

1(3G2,5)

10 44

1,77 2,65

SIEMENS

5SU13567KK16

Monofase

1516 16

0,03 4,58

0,03

701

1,11E+4

1,28E+5

1,1E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDPT/NOR. C-20

PRESE DISERVIZIO

1(3G2,5)

10 44

1,77 2,65

SIEMENS

5SU13567KK16

Monofase

1516 16

0,03 4,58

0,03

701

1,11E+4

1,28E+5

1,1E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDPT/NOR. C-21

PRESESCRIVANIA 1

1(3G2,5)

10 44

1,77 2,65

SIEMENS

5SU13567KK16

Monofase

1516 16

0,03 4,58

0,03

701

1,11E+4

1,28E+5

1,1E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDPT/NOR. C-22

PRESESCRIVANIA 2

1(3G2,5)

10 44

1,77 2,65

SIEMENS

5SU13567KK16

Monofase

1516 16

0,03 4,58

0,03

701

1,11E+4

1,28E+5

1,1E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDPT/NOR. C-23

PRESE SERVIZIOSUPP. PROCESSI

1(3G2,5)

10 44

1,77 2,65

SIEMENS

5SU13567KK16

Monofase

1516 16

0,03 4,58

0,03

701

1,11E+4

1,28E+5

1,1E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

18 18

21

25

21

25

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

7 8ver002007UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO PT

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDPT/NOR. C-24

RACKDATI

1(3G2,5)

10 45

1,74 2,54

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 4,58

0,03

701

1,19E+4

1,28E+5

1,16E+4

1,28E+5

1,19E+4

1,28E+5

9,623

16 16

26 26

21

38

21

38

QDPT/NOR. C-25

RISERVA

---

--- ---

1,04 1,42

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 4,58

0,03

2 768

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QDPT/NOR. C-26

RISERVA

---

--- ---

1,04 1,41

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 4,58

0,03

2 557

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDPT/PR.

QDPT/PR.

8 9ver002008UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO PT

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDPT/PR. C-0

GENERALE SEZ.PRIVILEGIATA

---

--- ---

1,91 3,06

SIEMENS

5TL14320

Quadripolare

---25 25

--- 1,81

0,3

4,86

---

---

---

---

---

---

9,623

25 25

--- ---

33

---

33

---

QDPT/PR. C-1

SPD

---

--- ---

1,91 3,06

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

2525 25

--- 1,8

0,3

4,86

---

---

---

---

---

---

0

25 25

--- ---

33

---

33

---

QDPT/PR. C-2

PRESENZA RETE

---

--- ---

1,91 3,49

SIEMENS

3NW6 Gr. 10x38 Ridotto

Tripolare

1002 2

--- 1,8

0,3

4,8

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QDPT/PR. C-3

PRESESCRIVANIA 1

1(3G2,5)

10 30

2,64 4,4

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 0,91

0,03

4,84

2,79E+3

1,28E+5

2,66E+3

1,28E+5

2,79E+3

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDPT/PR. C-4

PRESESCRIVANIA 2

1(3G2,5)

10 30

2,64 4,4

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 0,91

0,03

4,84

2,79E+3

1,28E+5

2,66E+3

1,28E+5

2,79E+3

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDPT/PR. C-5

RISERVA

---

--- ---

1,91 3,17

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 0,91

0,03

4,86

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QDPT/PR. C-6

RISERVA

---

--- ---

1,91 3,16

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 0,91

0,03

4,86

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

9 10ver003009UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO TECNICO

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLT/NOR. C-0

GENERALESEZ. NORMALE

---

--- ---

1,55 2,07

SIEMENS

5TL16631

Quadripolare

---50 50

--- 4,51

0,3

1 429

---

---

---

---

---

---

36

50 50

--- ---

65

---

65

---

QLT/NOR. C-1

SPD

---

--- ---

1,55 2,07

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

2550 50

--- 4,47

0,3

1 429

---

---

---

---

---

---

0

50 50

--- ---

65

---

65

---

QLT/NOR. C-2

PRESENZA RETE

---

--- ---

1,55 2,5

SIEMENS

3NW6 Gr. 10x38 Ridotto

Tripolare

1002 2

--- 4,47

0,3

225

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QLT/NOR. C-3---

--- ---

1,58 2,17

SIEMENS

5SU13537KK10

Monofase

11,2510 10

0,03 2,19

0,03

1 266

---

---

---

---

---

---

2,887

10 10

--- ---

13

---

13

---

QLT/NOR. C-4

ORDINARIA

1(3G1,5)

12 93

1,89 3,59

---

------10 10

--- 1,96

0,03

339

5,76E+3

4,6E+4

5,58E+3

4,6E+4

5,76E+3

4,6E+4

2,406

10 10

15 15

13

22

13

22

QLT/NOR. C-5

EMERGENZA

1(3G1,5)

8 467

1,62 3,12

---

------10 10

--- 1,96

0,03

448

5,76E+3

4,6E+4

5,58E+3

4,6E+4

5,76E+3

4,6E+4

0,481

10 10

15 15

13

22

13

22

QLT/NOR. C-6

FRIGOCOMBINATO

1(3G2,5)

10 49

2,08 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

7,217

16 16

18 18

21

25

21

25

QLT/NOR. C-7

ULTRACENTRIFUGA

1(3G2,5)

10 49

2,08 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

7,217

16 16

18 18

21

25

21

25

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

10 11ver003010UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO TECNICO

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLT/NOR. C-8

AUTOCLAVEPICCOLA

1(3G2,5)

10 49

2,08 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

7,217

16 16

18 18

21

25

21

25

QLT/NOR. C-9

INCUB.PIASTRE

1(3G2,5)

10 49

2,08 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

7,217

16 16

18 18

21

25

21

25

QLT/NOR. C-10

LIOFILIZZATORE

1(3G2,5)

10 49

2,08 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

7,217

16 16

18 18

21

25

21

25

QLT/NOR. C-11

SIST PURIFIC.H2O

1(3G2,5)

10 49

2,08 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

7,217

16 16

18 18

21

25

21

25

QLT/NOR. C-12

CABINA A FLUSSOLAMINARE

1(3G2,5)

10 49

2,08 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

7,217

16 16

18 18

21

25

21

25

QLT/NOR. C-13

AUTOCLAVEGRANDE

1(3G2,5)

10 49

2,08 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

7,217

16 16

18 18

21

25

21

25

QLT/NOR. C-14

BANCO 1

1(3G2,5)

10 22

2,7 3,37

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

14

16 16

20 20

21

28

21

28

QLT/NOR. C-15

BANCO 2

1(3G2,5)

10 22

2,7 3,37

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

14

16 16

20 20

21

28

21

28

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

11 12ver003011UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO TECNICO

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLT/NOR. C-16

BANCO 3

1(3G2,5)

10 22

2,7 3,37

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

14

16 16

20 20

21

28

21

28

QLT/NOR. C-17

LAVAVETRERIA

1(5G6)

15 103

1,94 2,73

SIEMENS

5SL44257+5SM23436

Quadripolare

1025 25

0,03 4,47

0,03

711

2,26E+4

7,36E+5

9,08E+3

7,36E+5

9,95E+3

7,36E+5

16

25 25

27 27

33

39

33

39

QLT/NOR. C-18

PRESE DISERVIZIO

1(3G2,5)

10 >99999

1,55 3,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

545

7,22E+3

1,28E+5

6,96E+3

1,28E+5

7,22E+3

1,28E+5

0

16 16

18 18

21

25

21

25

QLT/NOR. C-19

RISERVA

---

--- ---

1,55 2,18

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,19

0,03

1 319

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QLT/NOR. C-20

RISERVA

---

--- ---

1,55 2,17

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 2,19

0,03

1 266

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

QLT/NOR. C-21

RISERVA

---

--- ---

1,55 2,17

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 2,19

0,03

1 266

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/PR

QLT/PR

12 13ver003012UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO LABORATORIO TECNICO

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLT/PR C-0

GENERALESEZ. PRIVILEGIATA

---

--- ---

2,08 3,06

SIEMENS

5TL14320

Quadripolare

---25 25

--- 1,81

0,3

4,86

---

---

---

---

---

---

14

25 25

--- ---

33

---

33

---

QLT/PR C-1

SPD

---

--- ---

2,08 3,06

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

2525 25

--- 1,8

0,3

4,86

---

---

---

---

---

---

0

25 25

--- ---

33

---

33

---

QLT/PR C-2

PRESENZA RETE

---

--- ---

2,08 3,49

SIEMENS

3NW6 Gr. 10x38 Ridotto

Tripolare

1002 2

--- 1,8

0,3

4,8

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QLT/PR C-3

BANCO 1

1(3G2,5)

10 18

3,21 4,34

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 0,91

0,03

4,84

2,79E+3

1,28E+5

2,66E+3

1,28E+5

2,79E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLT/PR C-4

BANCO 2

1(3G2,5)

10 18

3,21 4,34

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 0,91

0,03

4,84

2,79E+3

1,28E+5

2,66E+3

1,28E+5

2,79E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLT/PR C-5

BANCO 3

1(3G2,5)

10 18

3,21 4,34

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 0,91

0,03

4,84

2,79E+3

1,28E+5

2,66E+3

1,28E+5

2,79E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLT/PR C-6

RISERVA

---

--- ---

2,08 3,17

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 0,91

0,03

4,86

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QLT/PR C-7

RISERVA

---

--- ---

2,08 3,16

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 0,91

0,03

4,86

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

13 14ver004013UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLAP/NOR. C-0

GENERALESEZ. NORMALE

---

--- ---

1,32 1,93

SIEMENS

5TL16631

Quadripolare

---63 50

--- 5,55

0,3

1 789

---

---

---

---

---

---

32

63 50

--- ---

82

---

65

---

QLAP/NOR. C-1

SPD

---

--- ---

1,32 1,93

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

2563 50

--- 5,49

0,3

1 789

---

---

---

---

---

---

0

63 50

--- ---

82

---

65

---

QLAP/NOR. C-2

PRESENZA RETE

---

--- ---

1,32 2,36

SIEMENS

3NW6 Gr. 10x38 Ridotto

Tripolare

1002 2

--- 5,49

0,3

232

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QLAP/NOR. C-3---

--- ---

1,35 2,03

SIEMENS

5SU13537KK10

Monofase

11,2510 10

0,03 2,71

0,03

1 544

---

---

---

---

---

---

2,887

10 10

--- ---

13

---

13

---

QLAP/NOR. C-4

ORDINARIA

1(3G1,5)

12 102

1,66 3,45

---

------10 10

--- 2,36

0,03

356

6,65E+3

4,6E+4

6,41E+3

4,6E+4

6,65E+3

4,6E+4

2,406

10 10

15 15

13

22

13

22

QLAP/NOR. C-5

EMERGENZA

1(3G1,5)

12 511

1,41 3,45

---

------10 10

--- 2,36

0,03

356

6,65E+3

4,6E+4

6,41E+3

4,6E+4

6,65E+3

4,6E+4

0,481

10 10

15 15

13

22

13

22

QLAP/NOR. C-6

BANCO 1

1(3G2,5)

10 25

2,45 3,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

591

8,5E+3

1,28E+5

8,15E+3

1,28E+5

8,5E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLAP/NOR. C-7

BANCO 2

1(3G2,5)

10 25

2,45 3,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

591

8,5E+3

1,28E+5

8,15E+3

1,28E+5

8,5E+3

1,28E+5

14

16 16

21 21

21

30

21

30

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

14 15ver004014UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLAP/NOR. C-8

BANCO 3

1(3G2,5)

10 25

2,45 3,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

591

8,5E+3

1,28E+5

8,15E+3

1,28E+5

8,5E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLAP/NOR. C-9

BANCO 4

1(3G2,5)

10 25

2,45 3,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

591

8,5E+3

1,28E+5

8,15E+3

1,28E+5

8,5E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLAP/NOR. C-10

BANCO 5

1(3G2,5)

10 25

2,45 3,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

591

8,5E+3

1,28E+5

8,15E+3

1,28E+5

8,5E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLAP/NOR. C-11

PRESE DISERVIZIO

1(3G2,5)

10 24

2,5 3,27

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

591

8,5E+3

1,28E+5

8,15E+3

1,28E+5

8,5E+3

1,28E+5

14

16 16

18 18

21

25

21

25

QLAP/NOR. C-12

AUSILIARI

---

--- ---

1,32 2,04

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

1 622

---

---

---

---

---

---

0,962

16 16

--- ---

21

---

21

---

QLAP/NOR. C-13

RISERVA

---

--- ---

1,32 2,04

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

1 622

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QLAP/NOR. C-14

RISERVA

---

--- ---

1,32 2,04

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 2,71

0,03

1 622

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QLAP/NOR. C-15

RISERVA

---

--- ---

1,32 2,03

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 2,71

0,03

1 544

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

15 16ver004015UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLAP/NOR. C-16

RISERVA

---

--- ---

1,32 2,03

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 2,71

0,03

1 544

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/PR.

QLAP.PR

16 17ver004016UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO LABORATORIO AREA PROCESSI

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLAP.PR C-0

GENERALE SEZ. PRIVILEGIATA

---

--- ---

2,29 2,93

SIEMENS

5TL14400

Quadripolare

---32 32

--- 2,26

0,3

4,87

---

---

---

---

---

---

29

32 32

--- ---

42

---

42

---

QLAP.PR C-1

SPD

---

--- ---

2,29 2,93

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

2532 32

--- 2,25

0,3

4,87

---

---

---

---

---

---

0

32 32

--- ---

42

---

42

---

QLAP.PR C-2

PRESENZA RETE

---

--- ---

2,29 3,36

SIEMENS

3NW6 Gr. 10x38 Ridotto

Tripolare

1002 2

--- 2,25

0,3

4,81

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QLAP.PR C-3

BANCO 1

1(3G2,5)

10 16

3,42 4,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 1,13

0,03

4,85

3,66E+3

1,28E+5

3,48E+3

1,28E+5

3,66E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLAP.PR C-4

BANCO 2

1(3G2,5)

10 16

3,42 4,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 1,13

0,03

4,85

3,66E+3

1,28E+5

3,48E+3

1,28E+5

3,66E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLAP.PR C-5

BANCO 3

1(3G2,5)

10 16

3,42 4,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 1,13

0,03

4,85

3,66E+3

1,28E+5

3,48E+3

1,28E+5

3,66E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLAP.PR C-6

BANCO 4

1(3G2,5)

10 16

3,42 4,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 1,13

0,03

4,85

3,66E+3

1,28E+5

3,48E+3

1,28E+5

3,66E+3

1,28E+5

14

16 16

21 21

21

30

21

30

QLAP.PR C-7

BANCO 5

1(3G2,5)

10 16

3,42 4,21

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 1,13

0,03

4,85

3,66E+3

1,28E+5

3,48E+3

1,28E+5

3,66E+3

1,28E+5

14

16 16

21 21

21

30

21

30

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/PR.

QLAP.PR

17 18ver004017UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO LABORATORIO AREA PROCESSI

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QLAP.PR C-8

RISERVA

---

--- ---

2,29 3,04

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 1,13

0,03

4,87

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QLAP.PR C-9

RISERVA

---

--- ---

2,29 3,03

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 1,13

0,03

4,87

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: UPS ESCLUSO DALLA FORNITURA E POSA IN OPERA

23/0

1/20

18

IEE-02-18

UPS-PT

UPS-PT

18 19ver005018UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

UPS-PT

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

UPS-PT C-0---

--- ---

1,59 2,14

---

------50 50

--- 4,44

0,3

4,88

---

---

---

---

---

---

37

50 50

--- ---

65

---

65

---

UPS-PT C-1

ALIM. SEZ. PRIVILEGIATAQLT

1(5G4)

15 78

2,07 3,05

SIEMENS

5SL44257

Quadripolare

1025 25

--- 4,44

0,3

4,86

2,33E+4

3,27E+5

9,39E+3

3,27E+5

1,01E+4

3,27E+5

14

25 25

30 30

33

44

33

44

UPS-PT C-2

ALIMENTAZ. SEZ. PRIV.QLAP

1(5G6)

15 54

2,28 2,92

SIEMENS

5SL44327

Quadripolare

1032 32

--- 4,44

0,3

4,87

3,07E+4

7,36E+5

1,25E+4

7,36E+5

1,33E+4

7,36E+5

29

32 32

39 39

42

56

42

56

UPS-PT C-3

ALIMENTAZIONE SEZ. PRIV.QDPT

1(5G4)

15 121

1,9 3,05

SIEMENS

5SL44257

Quadripolare

1025 25

--- 4,44

0,3

4,86

2,33E+4

3,27E+5

9,39E+3

3,27E+5

1,01E+4

3,27E+5

9,623

25 25

30 30

33

44

33

44

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

19 20ver006019UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO P1

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDP1/NOR. C-0

GENERALE SEZ.NORMALE

---

--- ---

0,91 1,3

SIEMENS

5TL16631

Quadripolare

---63 63

--- 8,26

756

3 185

---

---

---

---

---

---

42

63 63

--- ---

82

---

82

---

QDP1/NOR. C-1

SPD

---

--- ---

0,91 1,3

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

2563 63

--- 8,13

756

3 185

---

---

---

---

---

---

0

63 63

--- ---

82

---

82

---

QDP1/NOR. C-2

PRESENZA RETE

---

--- ---

0,91 1,73

SIEMENS

3NW6 Gr. 10x38 Ridotto

Tripolare

1002 2

--- 8,13

13

247

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QDP1/NOR. C-3

ALIMENTAZIONE UPS PIANO 1

1(5G4)

15 64

1,66 2,51

SIEMENS

5SY64327+5SM26458

Quadripolare

1532 32

0,3 8,13

0,3

752

4,09E+4

3,27E+5

1,95E+4

3,27E+5

2,13E+4

3,27E+5

22

32 32

34 34

42

49

42

49

QDP1/NOR. C-4

GENERALE ILLUMINAZIONECORRIDOIO

---

--- ---

0,95 1,4

SIEMENS

5SU13537KK10

Monofase

11,2510 10

0,03 4,54

0,03

2 508

---

---

---

---

---

---

3,849

10 10

--- ---

13

---

13

---

QDP1/NOR. C-5

ORDINARIA CORRIDOIO

1(3G1,5)

20 117

1,47 3,7

---

------10 10

--- 3,71

0,03

250

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

2,406

10 10

19 19

13

27

13

27

QDP1/NOR. C-6

ORDINARIA DISIMPEGNO

1(3G1,5)

20 294

1,16 3,7

---

------10 10

--- 3,71

0,03

250

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

0,962

10 10

19 19

13

27

13

27

QDP1/NOR. C-7

EMERGENZA

1(3G1,5)

20 588

1,05 3,7

---

------10 10

--- 3,71

0,03

250

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

0,481

10 10

19 19

13

27

13

27

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

20 21ver006020UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO P1

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDP1/NOR. C-8

GENERALE ILLUMINAZIONEUFFICI E INFORMATICA

---

--- ---

0,95 1,4

SIEMENS

5SU13537KK10

Monofase

11,2510 10

0,03 4,54

0,03

2 508

---

---

---

---

---

---

3,849

10 10

--- ---

13

---

13

---

QDP1/NOR. C-9

ORDINARIA UFFICIO 1

1(3G1,5)

20 117

1,47 3,7

---

------10 10

--- 3,71

0,03

250

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

2,406

10 10

19 19

13

27

13

27

QDP1/NOR. C-10

ORDINARIA UFF.2 E INFORMATICA

1(3G1,5)

20 294

1,16 3,7

---

------10 10

--- 3,71

0,03

250

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

0,962

10 10

19 19

13

27

13

27

QDP1/NOR. C-11

EMERGENZA

1(3G1,5)

20 588

1,05 3,7

---

------10 10

--- 3,71

0,03

250

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

0,481

10 10

19 19

13

27

13

27

QDP1/NOR. C-12

GENERALE ILLUMINAZIONERIUNIONI E SUPP. TEC.

---

--- ---

0,95 1,4

SIEMENS

5SU13537KK10

Monofase

11,2510 10

0,03 4,54

0,03

2 508

---

---

---

---

---

---

3,849

10 10

--- ---

13

---

13

---

QDP1/NOR. C-13

ORDINARIA RIUNIONI

1(3G1,5)

20 117

1,47 3,7

---

------10 10

--- 3,71

0,03

250

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

2,406

10 10

19 19

13

27

13

27

QDP1/NOR. C-14

ORDINARIA SUPPORTO TECNICO

1(3G1,5)

20 294

1,16 3,7

---

------10 10

--- 3,71

0,03

250

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

0,962

10 10

19 19

13

27

13

27

QDP1/NOR. C-15

EMERGENZA

1(3G1,5)

25 588

1,08 4,27

---

------10 10

--- 3,71

0,03

204

8,99E+3

4,6E+4

8,78E+3

4,6E+4

8,99E+3

4,6E+4

0,481

10 10

19 19

13

27

13

27

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

21 22ver006021UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO P1

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDP1/NOR. C-16

FM FAN COILRECUPERATORE

1(3G2,5)

10 64

1,43 2,53

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 4,54

0,03

696

1,11E+4

1,28E+5

1,09E+4

1,28E+5

1,11E+4

1,28E+5

7,217

16 16

26 26

21

38

21

38

QDP1/NOR. C-17

RACKDATI

1(3G2,5)

5 47

1,3 1,97

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 4,54

0,03

1 114

1,11E+4

1,28E+5

1,09E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

26 26

21

38

21

38

QDP1/NOR. C-18

PRESEDI SERVIZIO

1(3G2,5)

15 45

1,97 3,26

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 4,54

0,03

505

1,11E+4

1,28E+5

1,09E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDP1/NOR. C-19

FM INFORMATICAE UFFICI

1(3G2,5)

5 45

1,31 2,02

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 4,54

0,03

1 114

1,11E+4

1,28E+5

1,09E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDP1/NOR. C-20

FM RIUNIONI E SUPP. TECNICO

1(3G2,5)

5 45

1,31 2,02

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 4,54

0,03

1 114

1,11E+4

1,28E+5

1,09E+4

1,28E+5

1,11E+4

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDP1/NOR. C-21

RISERVA

---

--- ---

0,91 1,41

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 4,54

0,03

2 713

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QDP1/NOR. C-22

RISERVA

---

--- ---

0,91 1,4

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 4,54

0,03

2 508

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/PR.

QDP1/PR.

22 23ver006022UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO P1

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDP1/PR. C-0

GENERALE SEZ.PRIVILEGIATA

---

--- ---

2,33 3,43

SIEMENS

5TL14320

Quadripolare

---25 25

--- 1,29

0,3

4,86

---

---

---

---

---

---

19

25 25

--- ---

33

---

33

---

QDP1/PR. C-1

SPD

---

--- ---

2,33 3,43

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

2525 25

--- 1,29

0,3

4,86

---

---

---

---

---

---

0

25 25

--- ---

33

---

33

---

QDP1/PR. C-2

PRESENZA RETE

---

--- ---

2,33 3,86

SIEMENS

3NW6 Gr. 10x38 Ridotto

Tripolare

1002 2

--- 1,29

0,3

4,8

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QDP1/PR. C-3

FM INFORMATICAE UFFICI

1(3G2,5)

5 24

2,72 4,15

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 0,67

0,03

4,85

1,89E+3

1,28E+5

1,82E+3

1,28E+5

1,89E+3

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDP1/PR. C-4

FM INFORMATICAE UFFICI

1(3G2,5)

5 24

2,72 4,15

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 0,67

0,03

4,85

1,89E+3

1,28E+5

1,82E+3

1,28E+5

1,89E+3

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDP1/PR. C-5

FM UFFICIO1

1(3G2,5)

5 24

2,72 4,15

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 0,67

0,03

4,85

1,89E+3

1,28E+5

1,82E+3

1,28E+5

1,89E+3

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDP1/PR. C-6

FM UFFICIO2

1(3G2,5)

5 24

2,72 4,15

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 0,67

0,03

4,85

1,89E+3

1,28E+5

1,82E+3

1,28E+5

1,89E+3

1,28E+5

9,623

16 16

18 18

21

25

21

25

QDP1/PR. C-7

FM SUPPORTO TECNICO

1(3G2,5)

5 24

2,72 4,15

SIEMENS

5SU13537KK16

Monofase

1516 16

0,03 0,67

0,03

4,85

1,89E+3

1,28E+5

1,82E+3

1,28E+5

1,89E+3

1,28E+5

9,623

16 16

18 18

21

25

21

25

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/PR.

QDP1/PR.

23 24ver006023UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO P1

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QDP1/PR. C-8

RISERVA

---

--- ---

2,33 3,54

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 0,67

0,03

4,86

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QDP1/PR. C-9

RISERVA

---

--- ---

2,33 3,53

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 0,67

0,03

4,86

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: FORNITURA E POSA IN OPERA UPS ESCLUSA DAL'APPALTO

23/0

1/20

18

IEE-02-18

UPS-P1

UPS-P1

24 25ver007024UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

UPS P1

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

UPS-P1 C-0---

--- ---

1,66 2,51

---

------32 32

--- 2,28

0,3

4,88

---

---

---

---

---

---

19

32 32

--- ---

42

---

42

---

UPS-P1 C-11(5G4)

15 55

2,32 3,42

SIEMENS

5SL44257

Quadripolare

1025 25

--- 2,28

0,3

4,86

1,06E+4

3,27E+5

4,58E+3

3,27E+5

4,81E+3

3,27E+5

19

25 25

30 30

33

44

33

44

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

25 26ver008025UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

QUADRO CENTRALE TERMICA

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QCT C-0

GENERALEQCT

---

--- ---

1,23 1,58

SIEMENS

3KA71224AA00

Quadripolare

---200 100

--- 9,41

2 400

3 602

---

---

---

---

---

---

171

200 100

--- ---

260

---

130

---

QCT C-1

SPD

---

--- ---

1,23 1,58

SIEMENS

Classe II - Up 1.4 kV normale + Seg. Fisso

Quadripolare

25200 100

--- 9,39

2 400

3 602

---

---

---

---

---

---

0

200 100

--- ---

260

---

130

---

QCT C-2---

--- ---

1,23 2,01

SIEMENS

3NW6 Gr. 10x38 SEGN.

Quadripolare

1002 2

--- 9,39

13

250

---

---

---

---

---

---

0

2 2

--- ---

4,2

---

4,2

---

QCT C-3

GRUPPOFRIGO

4(1x35)+(1PE35)

40 53

2,27 3,01

SIEMENS

3VA11 L/T TM210 FTFM 3R

Quadripolare

25125 125

--- 9,39

1 500

1 750

1,75E+5

2,51E+7

1,27E+5

2,51E+7

1,28E+5

2,51E+7

96

125 125

144 144

163

209

163

209

QCT C-4

UTA 1

3(1x25)+(1x16)+(1PE16)

40 42

2,16 2,89

SIEMENS

3VA11 L/T TM220 ATFM 3RN/2

Quadripolare

2580 40

--- 9,39

1 200

1 246

1,75E+5

1,28E+7

1,27E+5

5,23E+6

1,27E+5

5,23E+6

61

80 40

82 62

104

119

52

89

QCT C-5---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

QCT C-6

EXT.02

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-7---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

26 27ver008026UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

QUADRO CENTRALE TERMICA

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QCT C-8

EXT.02

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-9---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

QCT C-10

EXT.02

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-11---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

QCT C-12

EXT.03

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-13---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

QCT C-14

EXT.04

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-15---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

27 28ver008027UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

QUADRO CENTRALE TERMICA

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QCT C-16

EXT.05

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-17---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

QCT C-18

EXT.06

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-19---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

QCT C-20

EXT.07

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-21---

--- ---

2,02 2,61

SIEMENS

3RV20110GA15

Tripolare

1000,63 0,63

--- 9,39

6,6

35

---

---

---

---

---

---

0,481

0,63 0,63

--- ---

0,756

---

0,756

---

QCT C-22

EXT.08

1(4G1,5)

15 676

2,06 2,67

SIEMENS

3RT20151AB01

Tripolare

---0,63 ---

--- 0,05

6,6

32

5,31

4,6E+4

---

---

5,3

4,6E+4

0,481

0,63 ---

7,41 ---

0,756

11

---

---

QCT C-23---

--- ---

1,42 1,83

SIEMENS

3RV20111DA10

Tripolare

1003,2 3,2

--- 9,39

43

634

---

---

---

---

---

---

2,486

3,2 3,2

--- ---

3,84

---

3,84

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

28 29ver008028UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

QUADRO CENTRALE TERMICA

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QCT C-24

EP.01-A

1(4G1,5)

15 119

1,64 2,11

SIEMENS

3RT20151AB01

Tripolare

---3,2 ---

--- 1,09

43

230

5,63E+2

4,6E+4

---

---

5,28E+2

4,6E+4

2,486

3,2 ---

7,41 ---

3,84

11

---

---

QCT C-25---

--- ---

1,42 1,77

SIEMENS

3RV20111DA10

Tripolare

1002,5 2,5

--- 9,39

43

634

---

---

---

---

---

---

2,486

2,5 2,5

--- ---

3

---

3

---

QCT C-26

EP.01-B

1(4G1,5)

15 119

1,64 1,99

SIEMENS

3RT20151AB01

Tripolare

---2,5 ---

--- 1,09

43

230

5,63E+2

4,6E+4

---

---

5,28E+2

4,6E+4

2,486

2,5 ---

7,41 ---

3

11

---

---

QCT C-27---

--- ---

1,4 1,75

SIEMENS

3RV20111DA10

Tripolare

1002,2 2,2

--- 9,39

43

634

---

---

---

---

---

---

2,197

2,2 2,2

--- ---

2,64

---

2,64

---

QCT C-28

EP.02-A

1(4G1,5)

15 119

1,59 1,94

SIEMENS

3RT20151AB01

Tripolare

---2,2 ---

--- 1,09

43

230

5,63E+2

4,6E+4

---

---

5,28E+2

4,6E+4

2,197

2,2 ---

7,41 ---

2,64

11

---

---

QCT C-29---

--- ---

1,4 1,83

SIEMENS

3RV20111DA10

Tripolare

1003,2 3,2

--- 9,39

43

634

---

---

---

---

---

---

2,197

3,2 3,2

--- ---

3,84

---

3,84

---

QCT C-30

EP.02-B

1(4G1,5)

15 119

1,59 2,11

SIEMENS

3RT20151AB01

Tripolare

---3,2 ---

--- 1,09

43

230

5,63E+2

4,6E+4

---

---

5,28E+2

4,6E+4

2,197

3,2 ---

7,41 ---

3,84

11

---

---

QCT C-31---

--- ---

1,61 2,1

SIEMENS

3RV20110KA15

Tripolare

1001,25 1,25

--- 9,39

16

133

---

---

---

---

---

---

0,898

1,25 1,25

--- ---

1,5

---

1,5

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

29 30ver008029UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

QUADRO CENTRALE TERMICA

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QCT C-32

EP.03-A

1(4G1,5)

15 303

1,68 2,21

SIEMENS

3RT20151AB01

Tripolare

---1,25 ---

--- 0,21

16

97

3,27E+1

4,6E+4

---

---

3,23E+1

4,6E+4

0,898

1,25 ---

7,41 ---

1,5

11

---

---

QCT C-33---

--- ---

1,61 2,1

SIEMENS

3RV20110KA15

Tripolare

1001,25 1,25

--- 9,39

16

133

---

---

---

---

---

---

0,898

1,25 1,25

--- ---

1,5

---

1,5

---

QCT C-34

EP.03-B

1(4G1,5)

15 303

1,68 2,21

SIEMENS

3RT20151AB01

Tripolare

---1,25 ---

--- 0,21

16

97

3,27E+1

4,6E+4

---

---

3,23E+1

4,6E+4

0,898

1,25 ---

7,41 ---

1,5

11

---

---

QCT C-35---

--- ---

1,43 2,1

SIEMENS

3RV20110KA15

Tripolare

1001,25 1,25

--- 9,39

16

133

---

---

---

---

---

---

0,481

1,25 1,25

--- ---

1,5

---

1,5

---

QCT C-36

EP.04-A

1(4G1,5)

15 303

1,48 2,21

SIEMENS

3RT20151AB01

Tripolare

---1,25 ---

--- 0,21

16

97

3,27E+1

4,6E+4

---

---

3,23E+1

4,6E+4

0,481

1,25 ---

7,41 ---

1,5

11

---

---

QCT C-37---

--- ---

1,43 2,1

SIEMENS

3RV20110KA15

Tripolare

1001,25 1,25

--- 9,39

16

133

---

---

---

---

---

---

0,481

1,25 1,25

--- ---

1,5

---

1,5

---

QCT C-38

EP.04-B

1(4G1,5)

15 303

1,48 2,21

SIEMENS

3RT20151AB01

Tripolare

---1,25 ---

--- 0,21

16

97

3,27E+1

4,6E+4

---

---

3,23E+1

4,6E+4

0,481

1,25 ---

7,41 ---

1,5

11

---

---

QCT C-39---

--- ---

1,4 1,78

SIEMENS

3RV20111EA10

Tripolare

1004 4

--- 9,39

52

909

---

---

---

---

---

---

3,304

4 4

--- ---

4,8

---

4,8

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

30 - ver008030UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

QUADRO CENTRALE TERMICA

TN-S 3F+N 400 10

VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI

(1)

(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

(12)

Descrizione

Conduttura

FormazioneLung. / Lung. max prot.[m]

C.di.T. % con Ib / In

Apparecchiatura

MarcaModelloPolarità

In F/NIdn

[A]

Contatti indiretti / Corto Circuito

IintIgt

[A]

P.d.I.Ik Max

[kA]

FaseI t

K S[A s]

2

2 22

NeutroI t

K S[A s]

2

22

2

PEI t

K S[A s]

2

2

2

2

Sovraccarico

IbIn F/NIz F/N

[A]

If F/N1,45 Iz F/N

[A]

Test

QCT C-40

EP.05-A

1(4G1,5)

15 100

1,69 2,14

SIEMENS

3RT20151AB01

Tripolare

---4 ---

--- 1,64

52

258

1,23E+3

4,6E+4

---

---

1,15E+3

4,6E+4

3,304

4 ---

7,41 ---

4,8

11

---

---

QCT C-41---

--- ---

1,4 1,78

SIEMENS

3RV20111EA10

Tripolare

1004 4

--- 9,39

52

909

---

---

---

---

---

---

3,304

4 4

--- ---

4,8

---

4,8

---

QCT C-42

EP.05-B

1(4G1,5)

15 100

1,69 2,14

SIEMENS

3RT20151AB01

Tripolare

---4 ---

--- 1,64

52

258

1,23E+3

4,6E+4

---

---

1,15E+3

4,6E+4

3,304

4 ---

7,41 ---

4,8

11

---

---

QCT C-43

AUSILIARI

---

--- ---

1,24 1,69

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 4,9

0,03

3 033

---

---

---

---

---

---

0,481

16 16

--- ---

21

---

21

---

QCT C-44

RISERVA

---

--- ---

1,23 1,69

SIEMENS

5SU13547KK16

Monofase

1016 16

0,03 4,9

0,03

3 033

---

---

---

---

---

---

0

16 16

--- ---

21

---

21

---

QCT C-45

RISERVA

---

--- ---

1,23 1,69

SIEMENS

5SU13547KK10

Monofase

1010 10

0,03 4,9

0,03

2 788

---

---

---

---

---

---

0

10 10

--- ---

13

---

13

---

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

1 2car001001UNIVERSITÁ SAPIENZA

ROMA

ELENCO DEI CARICHI

Nelle pagine seguenti è riportato l'elenco dei carichi elettricipresenti nell'impianto

Progetto INTEGRA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

2 3car002002UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO PT

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QDPT/NOR. C-6AUSILIARI Utenza generica

Monofase L1+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDPT/NOR. C-7BATTERIEDI POST

Utenza genericaMonofase L3+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QDPT/NOR. C-9ORDINARIADEPOSITO

Utenza genericaMonofase L1+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDPT/NOR. C-10ORDINARIA CORRIDOIOE FILTRO

Utenza genericaMonofase L1+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDPT/NOR. C-11ORDINARIADISIMPEGNO

Utenza genericaMonofase L1+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDPT/NOR. C-12EMERGENZA Utenza generica

Monofase L1+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

QDPT/NOR. C-14ORDINARIA Utenza generica

Monofase L1+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDPT/NOR. C-15EMERGENZA Utenza generica

Monofase L1+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

QDPT/NOR. C-17ORDINARIA Utenza generica

Monofase L2+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDPT/NOR. C-18EMERGENZA Utenza generica

Monofase L2+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

QDPT/NOR. C-19PRESE FRIGORIFERI

Utenza genericaMonofase L3+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDPT/NOR. C-20PRESE DISERVIZIO

Utenza genericaMonofase L1+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE

23/0

1/20

18

IEE-02-18

QDPT/NOR.

QDPT/NOR.

3 4car002003UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO PT

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QDPT/NOR. C-21PRESESCRIVANIA 1

Utenza genericaMonofase L2+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDPT/NOR. C-22PRESESCRIVANIA 2

Utenza genericaMonofase L3+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDPT/NOR. C-23PRESE SERVIZIOSUPP. PROCESSI

Utenza genericaMonofase L1+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDPT/NOR. C-24RACKDATI

Utenza genericaMonofase L2+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDPT/PR.

QDPT/PR.

4 5car002004UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO PT

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QDPT/PR. C-3PRESESCRIVANIA 1

Utenza genericaMonofase L1+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDPT/PR. C-4PRESESCRIVANIA 2

Utenza genericaMonofase L2+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

5 6car003005UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO TECNICO

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QLT/NOR. C-4ORDINARIA Utenza generica

Monofase L1+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QLT/NOR. C-5EMERGENZA Utenza generica

Monofase L1+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

QLT/NOR. C-6FRIGOCOMBINATO

Utenza genericaMonofase L2+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QLT/NOR. C-7ULTRACENTRIFUGA Utenza generica

Monofase L3+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QLT/NOR. C-8AUTOCLAVEPICCOLA

Utenza genericaMonofase L1+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QLT/NOR. C-9INCUB.PIASTRE

Utenza genericaMonofase L2+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QLT/NOR. C-10LIOFILIZZATORE Utenza generica

Monofase L3+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QLT/NOR. C-11SIST PURIFIC.H2O

Utenza genericaMonofase L1+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QLT/NOR. C-12CABINA A FLUSSOLAMINARE

Utenza genericaMonofase L2+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QLT/NOR. C-13AUTOCLAVEGRANDE

Utenza genericaMonofase L3+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QLT/NOR. C-14BANCO 1 Utenza generica

Monofase L1+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLT/NOR. C-15BANCO 2 Utenza generica

Monofase L2+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/NOR.

QLT/NOR.

6 7car003006UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO TECNICO

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QLT/NOR. C-16BANCO 3 Utenza generica

Monofase L3+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLT/NOR. C-17LAVAVETRERIA Utenza generica

Quadripolare

400 V11 10 0,9 16 100

0 20 40 60 80 100

QLT/NOR. C-18PRESE DISERVIZIO

Utenza genericaMonofase L3+N

230 V0 0 --- 0 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLT/PR

QLT/PR

7 8car003007UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO LABORATORIO TECNICO

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QLT/PR C-3BANCO 1 Utenza generica

Monofase L1+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLT/PR C-4BANCO 2 Utenza generica

Monofase L2+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLT/PR C-5BANCO 3 Utenza generica

Monofase L3+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/NOR.

QLAP/NOR.

8 9car004008UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QLAP/NOR. C-4ORDINARIA Utenza generica

Monofase L1+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QLAP/NOR. C-5EMERGENZA Utenza generica

Monofase L1+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

QLAP/NOR. C-6BANCO 1 Utenza generica

Monofase L2+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP/NOR. C-7BANCO 2 Utenza generica

Monofase L3+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP/NOR. C-8BANCO 3 Utenza generica

Monofase L1+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP/NOR. C-9BANCO 4 Utenza generica

Monofase L2+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP/NOR. C-10BANCO 5 Utenza generica

Monofase L3+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP/NOR. C-11PRESE DISERVIZIO

Utenza genericaMonofase L1+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP/NOR. C-12AUSILIARI Utenza generica

Monofase L2+N

230 V0,222 0,2 0,9 0,962 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QLAP/PR.

QLAP.PR

9 10car004009UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO LABORATORIO AREA PROCESSI

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QLAP.PR C-3BANCO 1 Utenza generica

Monofase L1+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP.PR C-4BANCO 2 Utenza generica

Monofase L2+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP.PR C-5BANCO 3 Utenza generica

Monofase L3+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP.PR C-6BANCO 4 Utenza generica

Monofase L1+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

QLAP.PR C-7BANCO 5 Utenza generica

Monofase L2+N

230 V3,333 3 0,9 14 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

10 11car006010UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO P1

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QDP1/NOR. C-5ORDINARIA CORRIDOIO

Utenza genericaMonofase L3+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDP1/NOR. C-6ORDINARIA DISIMPEGNO

Utenza genericaMonofase L3+N

230 V0,222 0,2 0,9 0,962 100

0 20 40 60 80 100

QDP1/NOR. C-7EMERGENZA Utenza generica

Monofase L3+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

QDP1/NOR. C-9ORDINARIA UFFICIO 1

Utenza genericaMonofase L1+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDP1/NOR. C-10ORDINARIA UFF.2 E INFORMATICA

Utenza genericaMonofase L1+N

230 V0,222 0,2 0,9 0,962 100

0 20 40 60 80 100

QDP1/NOR. C-11EMERGENZA Utenza generica

Monofase L1+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

QDP1/NOR. C-13ORDINARIA RIUNIONI

Utenza genericaMonofase L3+N

230 V0,556 0,5 0,9 2,406 100

0 20 40 60 80 100

QDP1/NOR. C-14ORDINARIA SUPPORTO TECNICO

Utenza genericaMonofase L3+N

230 V0,222 0,2 0,9 0,962 100

0 20 40 60 80 100

QDP1/NOR. C-15EMERGENZA Utenza generica

Monofase L3+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

QDP1/NOR. C-16FM FAN COILRECUPERATORE

Utenza genericaMonofase L1+N

230 V1,667 1,5 0,9 7,217 100

0 20 40 60 80 100

QDP1/NOR. C-17RACKDATI

Utenza genericaMonofase L2+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDP1/NOR. C-18PRESEDI SERVIZIO

Utenza genericaMonofase L3+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/NOR.

QDP1/NOR.

11 12car006011UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE NORMALEQUADRO P1

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QDP1/NOR. C-19FM INFORMATICAE UFFICI

Utenza genericaMonofase L1+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDP1/NOR. C-20FM RIUNIONI E SUPP. TECNICO

Utenza genericaMonofase L2+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

QDP1/PR.

QDP1/PR.

12 13car006012UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

SEZIONE PRIVILEGIATAQUADRO P1

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QDP1/PR. C-3FM INFORMATICAE UFFICI

Utenza genericaMonofase L1+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDP1/PR. C-4FM INFORMATICAE UFFICI

Utenza genericaMonofase L2+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDP1/PR. C-5FM UFFICIO1

Utenza genericaMonofase L3+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDP1/PR. C-6FM UFFICIO2

Utenza genericaMonofase L1+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

QDP1/PR. C-7FM SUPPORTO TECNICO

Utenza genericaMonofase L2+N

230 V2,222 2 0,9 9,623 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

13 14car008013UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

QUADRO CENTRALE TERMICA

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QCT C-3GRUPPOFRIGO

Utenza genericaQuadripolare

400 V67 60 0,9 96 100

0 20 40 60 80 100

QCT C-4UTA 1 Utenza generica

Quadripolare

400 V42 38 0,9 61 100

0 20 40 60 80 100

QCT C-6EXT.02 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-8EXT.02 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-10EXT.02 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-12EXT.03 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-14EXT.04 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-16EXT.05 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-18EXT.06 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-20EXT.07 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-22EXT.08 Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-24EP.01-A Utenza generica

Tripolare

400 V1,722 1,55 0,9 2,486 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18QCT

14 - car008014UNIVERSITÁ SAPIENZA

ROMA

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRASistema

QUADRO CENTRALE TERMICA

TN-S 3F+N 400 10

Descrizione

ELENCO DEI CARICHI INSTALLATI

Tipo PolaritàTensione

Potenza

[kVA] [kW] cosphi

Ib[A]

Ku[%]

QCT C-26EP.01-B Utenza generica

Tripolare

400 V1,722 1,55 0,9 2,486 100

0 20 40 60 80 100

QCT C-28EP.02-A Utenza generica

Tripolare

400 V1,522 1,37 0,9 2,197 100

0 20 40 60 80 100

QCT C-30EP.02-B Utenza generica

Tripolare

400 V1,522 1,37 0,9 2,197 100

0 20 40 60 80 100

QCT C-32EP.03-A Utenza generica

Tripolare

400 V0,622 0,56 0,9 0,898 100

0 20 40 60 80 100

QCT C-34EP.03-B Utenza generica

Tripolare

400 V0,622 0,56 0,9 0,898 100

0 20 40 60 80 100

QCT C-36EP.04-A Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-38EP.04-B Utenza generica

Tripolare

400 V0,333 0,3 0,9 0,481 100

0 20 40 60 80 100

QCT C-40EP.05-A Utenza generica

Tripolare

400 V2,289 2,06 0,9 3,304 100

0 20 40 60 80 100

QCT C-42EP.05-B Utenza generica

Tripolare

400 V2,289 2,06 0,9 3,304 100

0 20 40 60 80 100

QCT C-43AUSILIARI Utenza generica

Monofase L3+N

230 V0,111 0,1 0,9 0,481 100

0 20 40 60 80 100

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

1 2pos008001UNIVERSITÁ SAPIENZA

ROMA

TIPOLOGIE DI POSA DEI CAVI

Nelle pagine seguenti è riportato l'elenco dei cavi,con le tipologie di posa utilizzate

Progetto INTEGRA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

2 - pos000002UNIVERSITÁ SAPIENZA

ROMATipi di pose utilizzate

DATI DELLA FORNITURA

Fasi Tensione [V]R [ ]terra ohm

Progetto INTEGRA

TIPOLOGIE DI POSA UTILIZZATE

Posa Norma riferimentoCodifica Posa CEI 64-8

Norma riferimentoCodifica Posa CEI 64-8

Posa

EPR32_

CEI 35024/1

Unipolare

Cavi senza guaina e cavimultipolari (o unipolari conguaina), posati su parete

con percorso verticale

EPR31_

CEI 35024/1

Unipolare

Cavi senza guaina e cavimultipolari (o unipolari conguaina), posati su paretecon percorso orizzontale

EPR13_

CEI 35024/1

Multipolare

Cavi multipolari (o unipolaricon guaina) .... e cavi conisolamento minerale: su

passerelle perforateEPR__2

CEI 35024/1

Multipolare

Cavi multipolari in tubiprotettivi circolari posatientro muri termicamente

isolanti

EPR_3A

CEI 35024/1

MultipolareCavi multipolari in tubi

protettivi circolari posati su odistanziati da pareti

EPR34A

CEI 35024/1

Multipolare

Cavi multipolari (o unipolaricon guaina) posati in canali

sospesi

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

1 2leg008001UNIVERSITÁ SAPIENZA

ROMA

Nelle pagine seguenti è riportata la legenda dei simboli graficiutilizzati per la stesura degli elaborati.

LEGENDA SIMBOLI GRAFICI

Progetto INTEGRA

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

2 3leg008002UNIVERSITÁ SAPIENZA

ROMA

V

Voltmetro

A

Amperometro contrasformatoreamperometrico

Hz Mult

Multimetro

M

Comando motorizzato Attuatore che siaziona ruotando

Id

Blocco differenziale Bloccoelettromagnetico Blocco termico

Bobina o dispositivodi comando

I >

Dispositivo dicomando di un relèa massima corrente

Dispositivo dicomando di un relèa minima corrente

Dispositivo dicomando di un relèa massima tensione

I <U > U <

Dispositivo dicomando di un relèa minima tensione

Trasformatore adue avvolgimenti

Meccanismo asgancio libero

Trasformatoredi isolamento

IdQ

Interruttoredifferenziale conrelè incorporato

Q

Interruttoreautomatico con relèmagnetico

Id

Q

Interruttore automaticomagnetico Differenziale

Q

Interruttore automaticomagnetoTermico conrelè o sganciatori

Id

Q

Interruttore automaticomagnetoTermicoDifferenziale

Q

Id

Q

Interruttore automaticocon sganciatoreTermicoDifferenziale

Cosfimetro

Presenza tensione

Id

Bobina di comandodi un relè adaggancio meccanico

Bobina di comando diun relè a rimanenza

Bobina di comando diun relè ad orologio

QS

Interruttore dimanovra-sezionatore

F

Interruttore dimanovra-sezionatore-fusibile

Trasformatoreamperometrico

Relè differenzialecon toroide

Trasformatoredi sicurezza

LegendaF - Fusibili

K - ContattoriNA - Contattinormalmente apertiNC - Contattinormalmente chiusiQ - InterruttoriQS - SezionatoriSC - Scambio

Q

Id

QQ

Interruttoreautomaticomagnetico estraibile

Interruttore automaticomagnetoTermicoDifferenziale estraibile

Interruttore automaticomagnetoTermicoestraibile

Relè passo-passo

K

Q

Frequenzimetrocon trasformatoreamperometrico

Interruttoreautomatico con relètermico

Trasformatoretriangolo-stella, secondariocon neutro accessibile

Terra di protezioneP - Presa

Trasformatore atre avvolgimenti

Dispositivo di protezioneper le sovratensioni SPD

Id - Relè differenzialiGE - Gruppo elettrogeno

ba

QS

QSQS

Q

51N

Q5051

Interruttore automatico Interruttore automatico50\51\51N x MT

Sezionatore Sezionatore di terra Sezionatore rotativo

Kt K K K

Bobina di comando diun relè temporizzato

Interruttore magnetoTermico con termicaregolabile-Salvamotore

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

23/0

1/20

18

IEE-02-18

3 - leg008003UNIVERSITÁ SAPIENZA

ROMA

Contatti ausiliari1NA e 1NC

2X 2X 2X 2X2X 2X 3X 3X

4X 4X4X 4X 8X8X

K

Contattore concontatti 1NA

K

Contattore concontatti 1NA e 1NC

K

Contattore concontatti 1NC

2X

K

Contattore concontatti 2NA

2X2X

K

Contattore concontatti 2NA e 2NC

2X

K

Contattore concontatti 2NC

3X

K

Contattore concontatti 3NA

4X

K

Contattore concontatti 4NA

K

Contattore concontatti 4NC

K

Contattore Contattoausiliario NA

4X

Legenda

3X

Contatti ausiliari1NA e 2NC

Contatti ausiliari2NA

Contatti ausiliari2NA e 1NC

Contatti ausiliari2NA e 2NC

Contatti ausiliari2NC

Contatti ausiliari2SC

Contatti ausiliari3NA

Contatti ausiliari3NA e 1NC

Contatti ausiliari3NC

Contatti ausiliari4NA

Contatti ausiliari4NA e 4NC

Contatti ausiliari4NC

Contatti ausiliari8NA

Contatti ausiliari8NA e 8NC

Contattoausiliario NC

Contattoausiliario SC

Contatto ausiliario1SC e 1NA

Contatto ausiliario1SC, 1NA e 1NC

8X

NA - Contattinormalmente aperti

SC - Scambio

GE - Gruppo elettrogeno

QS - SezionatoriQ - Interruttori

NC - Contattinormalmente chiusi

P - Presa

K - ContattoriId - Relè differenziali

FU - Fusibile

Commutatore

kWh

RETE GE QS

Conduttura trifase conconduttore di neutroMorsettoContatore dell'ente

distributore Punto di connessione

CondensatoreInterblocco meccanicotra rete e GE

GE

FU

Componente oapparecchio di classe IIGruppo elettrogeno Morsetto

Fusibile

Simbolo di estraibile

PP

Presa con contattodi protezione

Presa interbloccatatripolare

Lampada o lampadadi segnalazione

Partenza fornitura

ChiaveInterruttoreorario

Interruttorecrepuscolare

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

UNIVERSITÁ SAPIENZA

ROMA

FRONTE QUADRO

Nelle pagine seguenti sono riportati i disegni dei FrontiQuadro

Progetto INTEGRA

fro000001

24/0

1/20

18

IEE-02-18

1 2

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

UNIVERSITÁ SAPIENZA

ROMA

QUADRO PTSEZIONE NORMALE

fro001002

24/0

1/20

18

IEE-02-18QDPT/NOR.

2 3

8 g f 2 560

8 g f 4 465

F 1C.01

8 G F 7 146

8 G F 7 146

8 g f 2 561

8 g f 4 465

8 G F 4 400

F 1C.02

QDPT/NOR. C-0 - 3KA711

1

0

8 G F 7 0 981

Pannello 1

8 G F 7 0 981

Pannello 2

8 G F 7 0 981

Pannello 3

8 G F 7 0 981

Pannello 4

MORSETTIERA

CORRENTE DI PICCO (kA):

FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:

PROFONDITA' (mm):LARGHEZZA (mm):

COLORE INVOLUCRO:

CORRENTE NOMINALE AMMISSIBILE x 1s (kA):

TIPO DI PORTA:

ALTEZZA (mm):

NORMA DI RIFERIMENTO:TIPO DI QUADRO:

DATI IDENTIFICATIVI DEL QUADRO

CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):

ACCESSIBILITA':

RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo

SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali

ALPHA 630CEI EN 61439-2

400/23002553

1.7501.020250

IP43 (senza porta IP3X)Forma 1

RAL 7035VEDI DISEGNOANTERIORE

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO TECNICOSEZIONE NORMALE

fro002003

24/0

1/20

18

IEE-02-18QLT/NOR.

3 4

8 g f 1 741

8 g f 4 462

F 1C.01

8 G F 7 0 981

Pannello 1

8 G F 7 0 981

Pannello 2

8 G F 7 0 981

Pannello 3

8 G F 7 0 981

Pannello 4

8 G F 7 0 981

Pannello 5

MORSETTIERA

CORRENTE DI PICCO (kA):

FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:

PROFONDITA' (mm):LARGHEZZA (mm):

COLORE INVOLUCRO:

CORRENTE NOMINALE AMMISSIBILE x 1s (kA):

TIPO DI PORTA:

ALTEZZA (mm):

NORMA DI RIFERIMENTO:TIPO DI QUADRO:

DATI IDENTIFICATIVI DEL QUADRO

CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):

ACCESSIBILITA':

RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo

SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali

ALPHA 630CEI EN 61439-2

400/23002553

1.250660250

IP43 (senza porta IP3X)Forma 1

RAL 7035VEDI DISEGNOANTERIORE

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

UNIVERSITÁ SAPIENZA

ROMA

QUADRO LABORATORIO AREA PROCESSISEZIONE NORMALE

fro003004

24/0

1/20

18

IEE-02-18QLAP/NOR.

4 5

8 G F 7 0 982

8 G F 7 0 983

F 1C.01

Pannello 1

CORRENTE DI PICCO (kA):

FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:

PROFONDITA' (mm):LARGHEZZA (mm):

COLORE INVOLUCRO:

CORRENTE NOMINALE AMMISSIBILE x 1s (kA):

TIPO DI PORTA:

ALTEZZA (mm):

NORMA DI RIFERIMENTO:TIPO DI QUADRO:

DATI IDENTIFICATIVI DEL QUADRO

CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):

ACCESSIBILITA':

RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo

SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali

ALPHA 125CEI 23-48 23-49

400/23001017

1.050660140

IP43 (senza porta IP3X)Forma 1

RAL 7035VEDI DISEGNOANTERIORE

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

UNIVERSITÁ SAPIENZA

ROMA

UPS-PT fro004005

24/0

1/20

18

IEE-02-18UPS-PT

5 6

C.01

CORRENTE DI PICCO (kA):

FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:

PROFONDITA' (mm):LARGHEZZA (mm):

COLORE INVOLUCRO:

CORRENTE NOMINALE AMMISSIBILE x 1s (kA):

TIPO DI PORTA:

ALTEZZA (mm):

NORMA DI RIFERIMENTO:TIPO DI QUADRO:

DATI IDENTIFICATIVI DEL QUADRO

CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):

ACCESSIBILITA':

RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo

SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali

CENTRALINOCEI 23-48 23-49 23-51

400/23001017

310465101

IP40VEDI DISEGNO

--VEDI DISEGNOANTERIORE

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

UNIVERSITÁ SAPIENZA

ROMA

QUADRO P1SEZIONE NORMALE

fro005006

24/0

1/20

18

IEE-02-18QDP1/NOR.

6 7

8 G F 7 0 982

8 G F 7 0 983

F 1C.01

Pannello 1

CORRENTE DI PICCO (kA):

FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:

PROFONDITA' (mm):LARGHEZZA (mm):

COLORE INVOLUCRO:

CORRENTE NOMINALE AMMISSIBILE x 1s (kA):

TIPO DI PORTA:

ALTEZZA (mm):

NORMA DI RIFERIMENTO:TIPO DI QUADRO:

DATI IDENTIFICATIVI DEL QUADRO

CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):

ACCESSIBILITA':

RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo

SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali

ALPHA 125CEI 23-48 23-49

400/23001017

1.050660140

IP43 (senza porta IP3X)Forma 1

RAL 7035VEDI DISEGNOANTERIORE

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

UNIVERSITÁ SAPIENZA

ROMA

UPS P1 fro006007

24/0

1/20

18

IEE-02-18UPS-P1

7 8

C.01CORRENTE DI PICCO (kA):

FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:

PROFONDITA' (mm):LARGHEZZA (mm):

COLORE INVOLUCRO:

CORRENTE NOMINALE AMMISSIBILE x 1s (kA):

TIPO DI PORTA:

ALTEZZA (mm):

NORMA DI RIFERIMENTO:TIPO DI QUADRO:

DATI IDENTIFICATIVI DEL QUADRO

CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):

ACCESSIBILITA':

RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo

SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali

CENTRALINOCEI 23-48 23-49 23-51

400/23001017

19324097

IP40VEDI DISEGNO

--VEDI DISEGNOANTERIORE

Segreteria
Rettangolo
Segreteria
Rettangolo

TITOLO COMMITTENTE SEGUE

CONTR.

DISEGNO

ELAB.

FILE FOGLIO

APPR.

F

E

D

C

B

A

1 32 4 5 6 7 8

F

E

D

C

B

A

1 32 4 5 6 7 8

CODICE

COMMESSA

PREFISSO

DAT

A:

NOTA:

UNIVERSITÁ SAPIENZA

ROMA

QUADRO CENTRALE TERMICA fro007008

24/0

1/20

18

IEE-02-18QCT

8 -

8 g f 2 580

8 g f 4 466

F 1C.01

8 G F 7 147

8 G F 7 147

8 g f 2 583

8 g f 4 466

8 G F 4 401

F 1C.02

QCT C-0 - 3KL712

1

0

8 G F 7 0 984

Pannello 1

8 G F 7 0 984

Pannello 2

3VA1 3VA1

8 G F 7 0 984

Pannello 3

8 G F 7 0 984

Pannello 4

MORSETTIERA

8 G F 9 674

CORRENTE DI PICCO (kA):

FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:

PROFONDITA' (mm):LARGHEZZA (mm):

COLORE INVOLUCRO:

CORRENTE NOMINALE AMMISSIBILE x 1s (kA):

TIPO DI PORTA:

ALTEZZA (mm):

NORMA DI RIFERIMENTO:TIPO DI QUADRO:

DATI IDENTIFICATIVI DEL QUADRO

CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):

ACCESSIBILITA':

RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo

SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali

ALPHA 630CEI EN 61439-2

400/23002553

2.1501.353251

IP55 (senza porta IP3X)Forma 1

RAL 7035VEDI DISEGNOANTERIORE

Segreteria
Rettangolo
Segreteria
Rettangolo