MODIFICHE PER VALIDAZIONE - uniroma1.it
Transcript of MODIFICHE PER VALIDAZIONE - uniroma1.it
TITOLO COMMITTENTE
CONTR.ELAB.
FILE
APPR.
DISEGNO DATA
UNIVERSITÁ SAPIENZA
ROMA
Progetto Impianto ElettricoSchema a blocchi
schema
23/01/2018
FORNITURA DA QUADRO GENERALE
400/230V - 50Hz - Ik = 15 kAQuadripolareSistema TN-SPotenza Contratto 0 kWPotenza Impianto 190 kW
Quadro Generale EDIFICIOQGEN: Ik = 12,26 [kA]Linea: FG16M16 / 30 mSezione: 3(1x185)+(1x95)+(1PE95)C.d.t. con: Ib 0,61 %
QUADRO PTQDPT/NOR.: Ik = 9,27 [kA]Linea: FG16M16/H07Z1-K_2 PE / 20 mSezione: 3(1x50)+(1x25)+(1PE25)C.d.t. con: Ib 1,03 %
QUADRO PTQDPT/PR.: Ik = 1,81 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G4)C.d.t. con: Ib 1,9 %
QUADRO LABORATORIO TECNICOQLT/NOR.: Ik = 4,51 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G10)C.d.t. con: Ib 1,54 %
QUADRO LABORATORIO TECNICOQLT/PR: Ik = 1,81 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G4)C.d.t. con: Ib 2,07 %
QUADRO LABORATORIO AREA PROCESSIQLAP/NOR.: Ik = 5,55 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G16)C.d.t. con: Ib 1,31 %
QUADRO LABORATORIO AREA PROCESSIQLAP.PR: Ik = 2,26 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G6)C.d.t. con: Ib 2,28 %
UPS-PTUPS-PT: Ik = 4,44 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G10)C.d.t. con: Ib 1,59 % ---
UPS
QUADRO P1QDP1/NOR.: Ik = 8,26 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G25)C.d.t. con: Ib 0,9 %
QUADRO P1QDP1/PR.: Ik = 1,29 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G4)C.d.t. con: Ib 2,32 %
UPS P1UPS-P1: Ik = 2,28 [kA]Linea: FG16OM16 / 15 mSezione: 1(5G4)C.d.t. con: Ib 1,66 %
UPS
QUADRO CENTRALE TERMICAQCT: Ik = 9,41 [kA]Linea: FG16M16/H07Z1-K_2 PE / 30 mSezione: 3(1x95)+(1x50)+(1PE50)C.d.t. con: Ib 1,23 %
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
1 2uni000001UNIVERSITÁ SAPIENZA
ROMA
SCHEMI UNIFILARI
Nelle pagine seguenti sono riportati gli schemi unifilari deiquadri elettrici presenti nell'impianto
Progetto INTEGRA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18QGEN
2 3
AL FG 3
uni001002UNIVERSITÁ SAPIENZA
ROMA
Quadro Generale EDIFICIO
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 12,157 kA
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QGEN
Quadripolare12,255
400
5015---
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
FORNITURA DA QUADRO GENERALEF C-0
3(1x185)+(1x95)+(1PE95)30
40050
Quadripolare
QGEN C-0
190
306
0,911
100
SIEMENS
VL400.LI.TM
Esecuzione Fissa
MagnetoTermico
315/250 / 315
3 150/1 575/3 150
55 / N.C.
---
Quadripolare
0,65
---
---
---
---
---
---
Q0
L1L2L3N.QGEN.1
CBD.701.2.3.4.T
QDPT/NOR.
QGEN C-1
ALIMENTAZIONE ORDINARIA
QUADRO PT
58
93
0,934
100
SIEMENS
3VA11 L/T TM220 ATFM 3RN/2
Esecuzione Fissa
MagnetoTermico
125/88 / 100
---/---/1 250
25 / N.C.
---
Quadripolare
1,03
FG16M16/H07Z1-K_2 PE
20
143/2U32_/30/0,7
0,700
3(1x50)+(1x25)+(1PE25)
123
Q1
L1L2L3N.QGEN.0
L1L2L3N.QGEN.2
CBD.355.6.7.8.T
QDP1/NOR.
QGEN C-2
ALIMENTAZIONE
QP1
25
42
0,9
100
SIEMENS
3VA10 L/T TM210 FTFM 3R
Esecuzione Fissa
MagnetoTermico
---/--- / 63
---/---/630
16 / N.C.
---
Quadripolare
0,9
FG16OM16
15
143/2M32_/30/0,7
0,700
1(5G25)
74
Q2
L1L2L3N.QGEN.0
L1L2L3N.QGEN.3
QGEN C-3
ALIMENTAZIONE
QCT
107
171
0,9
100
SIEMENS
3VA12 L/T TM240 ATAM 3RN/2
Esecuzione Fissa
MagnetoTermico
200/140 / 200
2 000/1 000/2 000
36 / N.C.
---
Quadripolare
1,23
FG16M16/H07Z1-K_2 PE
30
143/2U31_/30/1
1,000
3(1x95)+(1x50)+(1PE50)
269
Q3
L1L2L3N.QGEN.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
3 4
AL FG 4
uni002003UNIVERSITÁ SAPIENZA
ROMA
QUADRO PTSEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,256 kA
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QDPT/NOR.
Quadripolare9,27400
5010---
QDPT/NOR.
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
QGENQGEN C-1
3(1x50)+(1x25)+(1PE25)20
40050
QuadripolareCBD.70
1.2.3.4.T
QDPT/NOR. C-0
GENERALE SEZ.
NORMALE
58
93
0,934
70
SIEMENS
3KA71164AA00
Esecuzione Fissa
Sezionatore
---/--- / 125
---/---/---
--- /
---
Quadripolare
1,04
---
---
---
---
---
---
QS0
L1L2L3N.QGEN.1
QDPT/NOR. C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
1,04
---
---
---
---
---
---
QDPT/NOR. C-2
PRESENZA RETE
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 Ridotto
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
1,04
---
---
---
---
---
---
QS
3
2
L1L2L3N.QDPT/NOR..3
CBD.165.6.7.8.T
QLT/NOR.
QDPT/NOR. C-3
ALIMENTAZIONE
QLT
22
36
0,9
100
SIEMENS
5SL44507+5SM26468
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 50
---/---/500
10 / C
0,3 - Cl. A S
Quadripolare
1,54
FG16OM16
15
143/3M13_/30/0,72
0,720
1(5G10)
54
Q3
L1L2L3N.QDPT/NOR..0
Id
L1L2L3N.QDPT/NOR..4
CBD.259.10.11.12.TQLAP/NOR.
QDPT/NOR. C-4
ALIMENTAZIONE
QLAP
19
32
0,9
100
SIEMENS
5SL44637+5SM26468
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 63
---/---/630
10 / C
0,3 - Cl. A S
Quadripolare
1,31
FG16OM16
15
143/3M13_/30/0,72
0,720
1(5G16)
72
Q4
L1L2L3N.QDPT/NOR..0
Id
L1L2L3N.QDPT/NOR..5
CBD.1613.14.15.16.T
UPS-PT
QDPT/NOR. C-5
ALIMENTAZIONE UPS
PIANO TERRA
25
36
0,99
100
SIEMENS
5SY64507+5SM26458
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 50
---/---/500
10 / C
0,3 - Cl. A S
Quadripolare
1,59
FG16OM16
15
143/3M13_/30/0,72
0,720
1(5G10)
54
Q5
L1L2L3N.QDPT/NOR..0
Id
A
L1N.QDPT/NOR..6
CBD.17.18.T
Utenza generica QDPT/NOR. C-6
QDPT/NOR. C-6
AUSILIARI
0,5
2,406
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
15 / C
0,03 - Cl. A
Monofase L1+N
1,06
---
---
---
---
---
---
Q
Id
6
L1N.QDPT/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
4 5
AL FG 5DAL FG 3
uni002004UNIVERSITÁ SAPIENZA
ROMA
QUADRO PTSEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,256 kAA
L3N.QDPT/NOR..7
CBD.419.20.T
Utenza generica QDPT/NOR. C-7
QDPT/NOR. C-7
BATTERIE
DI POST
1,5
7,217
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
15 / C
0,03 - Cl. A
Monofase L3+N
3,12
FG16OM16
25
143/3M13_/30/0,72
0,720
1(3G1,5)
19
Q
Id
7
L3N.QDPT/NOR..0
QDPT/NOR. C-8
GENERALE ILLUMINAZIONE
CORRIDOIO
1,6
7,698
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
11,25 / C
0,03 - Cl. A
Monofase L1+N
1,12
---
---
---
---
---
---
Q
Id
8
L1N.QDPT/NOR..0
L1N.QDPT/NOR..8
CBD.421.22.T
Utenza generica QDPT/NOR. C-9
QDPT/NOR. C-9
ORDINARIA
DEPOSITO
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,3
FG16OM16
7
143/3M13_/30/0,72
0,720
1(3G1,5)
19
L1N.QDPT/NOR..8
CBD.423.24.T
Utenza generica QDPT/NOR. C-10
QDPT/NOR. C-10
ORDINARIA CORRIDOIO
E FILTRO
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,77
FG16OM16
25
143/3M13_/30/0,72
0,720
1(3G1,5)
19
K10
L1N.QDPT/NOR..8
CBD.425.26.T
Utenza generica QDPT/NOR. C-11
QDPT/NOR. C-11
ORDINARIA
DISIMPEGNO
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,77
FG16OM16
25
143/3M13_/30/0,72
0,720
1(3G1,5)
19
K11
L1N.QDPT/NOR..8
CBD.427.28.T
Utenza generica QDPT/NOR. C-12
QDPT/NOR. C-12
EMERGENZA
0,1
0,481
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,25
FG16OM16
25
143/3M13_/30/0,72
0,720
1(3G1,5)
19
A
QDPT/NOR. C-13
GENERALE ILLUMINAZIONE
AREA PROCESSI
0,6
2,887
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
11,25 / C
0,03 - Cl. A
Monofase L1+N
1,07
---
---
---
---
---
---
Q
Id
13
L1N.QDPT/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
5 6
AL FG 6DAL FG 4
uni002005UNIVERSITÁ SAPIENZA
ROMA
QUADRO PTSEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,256 kAAB
L1N.QDPT/NOR..13
CBD.429.30.T
Utenza generica QDPT/NOR. C-14
QDPT/NOR. C-14
ORDINARIA
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,46
FG16OM16
15
143/3M13_/30/0,72
0,720
1(3G1,5)
19
K14
L1N.QDPT/NOR..13
CBD.431.32.T
Utenza generica QDPT/NOR. C-15
QDPT/NOR. C-15
EMERGENZA
0,1
0,481
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,14
FG16OM16
15
143/3M13_/30/0,72
0,720
1(3G1,5)
19
QDPT/NOR. C-16
GENERALE ILLUMINAZIONE
DIDATTICA
0,6
2,887
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
11,25 / C
0,03 - Cl. A
Monofase L2+N
1,07
---
---
---
---
---
---
Q
Id
16
L2N.QDPT/NOR..0
L2N.QDPT/NOR..16
CBD.433.34.T
Utenza generica QDPT/NOR. C-17
QDPT/NOR. C-17
ORDINARIA
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L2+N
1,59
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
K17
L2N.QDPT/NOR..16
CBD.435.36.T
Utenza generica QDPT/NOR. C-18
QDPT/NOR. C-18
EMERGENZA
0,1
0,481
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L2+N
1,17
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
L3N.QDPT/NOR..19
CBD.437.38.T
Utenza generica QDPT/NOR. C-19
QDPT/NOR. C-19
PRESE
FRIGORIFERI
2
9,623
0,9
100
SIEMENS
5SU13567KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L3+N
1,77
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
19
L3N.QDPT/NOR..0
A
L1N.QDPT/NOR..20
CBD.439.40.T
Utenza generica QDPT/NOR. C-20
QDPT/NOR. C-20
PRESE DI
SERVIZIO
2
9,623
0,9
100
SIEMENS
5SU13567KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L1+N
1,77
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
20
L1N.QDPT/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
6 7
AL FG 7DAL FG 5
uni002006UNIVERSITÁ SAPIENZA
ROMA
QUADRO PTSEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,256 kAA
L2N.QDPT/NOR..21
CBD.441.42.T
Utenza generica QDPT/NOR. C-21
QDPT/NOR. C-21
PRESE
SCRIVANIA 1
2
9,623
0,9
100
SIEMENS
5SU13567KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L2+N
1,77
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
21
L2N.QDPT/NOR..0
L3N.QDPT/NOR..22
CBD.443.44.T
Utenza generica QDPT/NOR. C-22
QDPT/NOR. C-22
PRESE
SCRIVANIA 2
2
9,623
0,9
100
SIEMENS
5SU13567KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L3+N
1,77
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
22
L3N.QDPT/NOR..0
L1N.QDPT/NOR..23
CBD.445.46.T
Utenza generica QDPT/NOR. C-23
QDPT/NOR. C-23
PRESE SERVIZIO
SUPP. PROCESSI
2
9,623
0,9
100
SIEMENS
5SU13567KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L1+N
1,77
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
23
L1N.QDPT/NOR..0
L2N.QDPT/NOR..24
CBD.447.48.T
Utenza generica QDPT/NOR. C-24
QDPT/NOR. C-24
RACK
DATI
2
9,623
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
1,74
FG16OM16
10
143/3M13_/30/0,72
0,720
1(3G2,5)
26
Q
Id
24
L2N.QDPT/NOR..0
L3N.QDPT/NOR..25
CBD.49.50.T
QDPT/NOR. C-25
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
1,04
---
---
---
---
---
---
Q
Id
25
L3N.QDPT/NOR..0
L1N.QDPT/NOR..26
CBD.51.52.T
QDPT/NOR. C-26
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L1+N
1,04
---
---
---
---
---
---
Q
Id
26
L1N.QDPT/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QDPT/PR.
QDPT/PR.
7 8
AL FG 8
uni002007UNIVERSITÁ SAPIENZA
ROMA
QUADRO PTSEZIONE PRIVILEGIATASchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 1,802 kA - Id: 0,3 A
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QDPT/PR.
Quadripolare1,812
400
504,5---
QDPT/PR.
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
UPS-PTUPS-PT C-3
1(5G4)15
40050
QuadripolareCBD.6
1.2.3.4.T
QDPT/PR. C-0
GENERALE SEZ.
PRIVILEGIATA
4
9,623
0,9
100
SIEMENS
5TL14320
Esecuzione Fissa
Sezionatore
---/--- / 32
---/---/---
--- /
---
Quadripolare
1,91
---
---
---
---
---
---
QS0
L1L2L3N.UPS-PT.3
QDPT/PR. C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
1,91
---
---
---
---
---
---
QDPT/PR. C-2
PRESENZA RETE
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 Ridotto
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
1,91
---
---
---
---
---
---
QS
3
2
L1N.QDPT/PR..3
CBD.45.6.T
Utenza generica QDPT/PR. C-3
QDPT/PR. C-3
PRESE
SCRIVANIA 1
2
9,623
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
2,64
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
3
L1N.QDPT/PR..0
L2N.QDPT/PR..4
CBD.47.8.T
Utenza generica QDPT/PR. C-4
QDPT/PR. C-4
PRESE
SCRIVANIA 2
2
9,623
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
2,64
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
4
L2N.QDPT/PR..0
L3N.QDPT/PR..5
CBD.9.10.T
QDPT/PR. C-5
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
1,91
---
---
---
---
---
---
Q
Id
5
L3N.QDPT/PR..0
A
L1N.QDPT/PR..6
CBD.11.12.T
QDPT/PR. C-6
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L1+N
1,91
---
---
---
---
---
---
Q
Id
6
L1N.QDPT/PR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
8 9
AL FG 9
uni003008UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO TECNICOSEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 4,466 kA - Id: 0,3 A
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QLT/NOR.
Quadripolare4,511
400
506
---QLT/NOR.
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
QDPT/NOR.QDPT/NOR. C-3
1(5G10)15
40050
QuadripolareCBD.16
1.2.3.4.T
QLT/NOR. C-0
GENERALE
SEZ. NORMALE
22
36
0,9
70
SIEMENS
5TL16631
Esecuzione Fissa
Sezionatore
---/--- / 63
---/---/---
--- /
---
Quadripolare
1,55
---
---
---
---
---
---
QS0
L1L2L3N.QDPT/NOR..3
QLT/NOR. C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
1,55
---
---
---
---
---
---
QLT/NOR. C-2
PRESENZA RETE
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 Ridotto
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
1,55
---
---
---
---
---
---
QS
3
2
QLT/NOR. C-3
0,6
2,887
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
11,25 / C
0,03 - Cl. A
Monofase L1+N
1,58
---
---
---
---
---
---
Q
Id
3
L1N.QLT/NOR..0
L1N.QLT/NOR..3
CBD.45.6.T
Utenza generica QLT/NOR. C-4
QLT/NOR. C-4
ORDINARIA
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,89
FG16OM16
12
143/2M_3A/30/0,7
0,700
1(3G1,5)
15
L1N.QLT/NOR..3
CBD.47.8.T
Utenza generica QLT/NOR. C-5
QLT/NOR. C-5
EMERGENZA
0,1
0,481
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,62
FG16OM16
8
143/2M_3A/30/0,7
0,700
1(3G1,5)
15
A
L2N.QLT/NOR..6
CBD.49.10.T
Utenza generica QLT/NOR. C-6
QLT/NOR. C-6
FRIGO
COMBINATO
1,5
7,217
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
2,08
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
6
L2N.QLT/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
9 10
AL FG 10DAL FG 8
uni003009UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO TECNICOSEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 4,466 kA - Id: 0,3 AA
L3N.QLT/NOR..7
CBD.411.12.T
Utenza generica QLT/NOR. C-7
QLT/NOR. C-7
ULTRACENTRIFUGA
1,5
7,217
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
2,08
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
7
L3N.QLT/NOR..0
L1N.QLT/NOR..8
CBD.413.14.T
Utenza generica QLT/NOR. C-8
QLT/NOR. C-8
AUTOCLAVE
PICCOLA
1,5
7,217
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
2,08
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
8
L1N.QLT/NOR..0
L2N.QLT/NOR..9
CBD.415.16.T
Utenza generica QLT/NOR. C-9
QLT/NOR. C-9
INCUB.
PIASTRE
1,5
7,217
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
2,08
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
9
L2N.QLT/NOR..0
L3N.QLT/NOR..10
CBD.417.18.T
Utenza generica QLT/NOR. C-10
QLT/NOR. C-10
LIOFILIZZATORE
1,5
7,217
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
2,08
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
10
L3N.QLT/NOR..0
L1N.QLT/NOR..11
CBD.419.20.T
Utenza generica QLT/NOR. C-11
QLT/NOR. C-11
SIST PURIFIC.
H2O
1,5
7,217
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
2,08
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
11
L1N.QLT/NOR..0
L2N.QLT/NOR..12
CBD.421.22.T
Utenza generica QLT/NOR. C-12
QLT/NOR. C-12
CABINA A FLUSSO
LAMINARE
1,5
7,217
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
2,08
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
12
L2N.QLT/NOR..0
A
L3N.QLT/NOR..13
CBD.423.24.T
Utenza generica QLT/NOR. C-13
QLT/NOR. C-13
AUTOCLAVE
GRANDE
1,5
7,217
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
2,08
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
13
L3N.QLT/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
10 11
AL FG 11DAL FG 9
uni003010UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO TECNICOSEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 4,466 kA - Id: 0,3 AA
L1N.QLT/NOR..14
CBD.425.26.T
Utenza generica QLT/NOR. C-14
QLT/NOR. C-14
BANCO 1
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
2,7
FG16OM16
10
143/2M_3A/30/0,65
0,650
1(3G2,5)
20
Q
Id
14
L1N.QLT/NOR..0
L2N.QLT/NOR..15
CBD.427.28.T
Utenza generica QLT/NOR. C-15
QLT/NOR. C-15
BANCO 2
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
2,7
FG16OM16
10
143/2M_3A/30/0,65
0,650
1(3G2,5)
20
Q
Id
15
L2N.QLT/NOR..0
L3N.QLT/NOR..16
CBD.429.30.T
Utenza generica QLT/NOR. C-16
QLT/NOR. C-16
BANCO 3
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
2,7
FG16OM16
10
143/2M_3A/30/0,65
0,650
1(3G2,5)
20
Q
Id
16
L3N.QLT/NOR..0
L1L2L3N.QLT/NOR..17
CBD.1031.32.33.34.T
Utenza generica QLT/NOR. C-17
QLT/NOR. C-17
LAVAVETRERIA
10
16
0,9
100
SIEMENS
5SL44257+5SM23436
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 25
---/---/250
10 / C
0,03 - Cl. A
Quadripolare
1,94
FG16OM16
15
143/1M__2/30/0,7
0,700
1(5G6)
27
Q17
L1L2L3N.QLT/NOR..0
Id
L3N.QLT/NOR..18
CBD.435.36.T
Utenza generica QLT/NOR. C-18
QLT/NOR. C-18
PRESE DI
SERVIZIO
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
1,55
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
18
L3N.QLT/NOR..0
L1N.QLT/NOR..19
CBD.37.38.T
QLT/NOR. C-19
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
1,55
---
---
---
---
---
---
Q
Id
19
L1N.QLT/NOR..0
A
L2N.QLT/NOR..20
CBD.39.40.T
QLT/NOR. C-20
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L2+N
1,55
---
---
---
---
---
---
Q
Id
20
L2N.QLT/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
11 12
AL FG 12DAL FG 10
uni003011UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO TECNICOSEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 4,466 kA - Id: 0,3 AA
L3N.QLT/NOR..21
CBD.41.42.T
QLT/NOR. C-21
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L3+N
1,55
---
---
---
---
---
---
Q
Id
21
L3N.QLT/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLT/PR
QLT/PR
12 13
AL FG 13
uni003012UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO TECNICOSEZIONE PRIVILEGIATASchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 1,802 kA - Id: 0,3 A
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QLT/PR
Quadripolare1,812
400
504,5---
QLT/PR
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
UPS-PTUPS-PT C-1
1(5G4)15
40050
QuadripolareCBD.6
1.2.3.4.T
QLT/PR C-0
GENERALE
SEZ. PRIVILEGIATA
9
14
0,9
100
SIEMENS
5TL14320
Esecuzione Fissa
Sezionatore
---/--- / 32
---/---/---
--- /
---
Quadripolare
2,08
---
---
---
---
---
---
QS0
L1L2L3N.UPS-PT.1
QLT/PR C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
2,08
---
---
---
---
---
---
QLT/PR C-2
PRESENZA RETE
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 Ridotto
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
2,08
---
---
---
---
---
---
QS
3
2
L1N.QLT/PR.3
CBD.45.6.T
Utenza generica QLT/PR C-3
QLT/PR C-3
BANCO 1
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
3,21
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
3
L1N.QLT/PR.0
L2N.QLT/PR.4
CBD.47.8.T
Utenza generica QLT/PR C-4
QLT/PR C-4
BANCO 2
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
3,21
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
4
L2N.QLT/PR.0
L3N.QLT/PR.5
CBD.49.10.T
Utenza generica QLT/PR C-5
QLT/PR C-5
BANCO 3
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
3,21
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
5
L3N.QLT/PR.0
A
L1N.QLT/PR.6
CBD.11.12.T
QLT/PR C-6
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
2,08
---
---
---
---
---
---
Q
Id
6
L1N.QLT/PR.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLT/PR
QLT/PR
13 14
AL FG 14DAL FG 12
uni003013UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO TECNICOSEZIONE PRIVILEGIATASchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 1,802 kA - Id: 0,3 AA
L2N.QLT/PR.7
CBD.13.14.T
QLT/PR C-7
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L2+N
2,08
---
---
---
---
---
---
Q
Id
7
L2N.QLT/PR.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
14 15
AL FG 15
uni004014UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO AREA PROCESSISEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 5,488 kA - Id: 0,3 A
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QLAP/NOR.
Quadripolare5,553
400
506
---QLAP/NOR.
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
QDPT/NOR.QDPT/NOR. C-4
1(5G16)15
40050
QuadripolareCBD.25
1.2.3.4.T
QLAP/NOR. C-0
GENERALE
SEZ. NORMALE
19
32
0,9
100
SIEMENS
5TL16631
Esecuzione Fissa
Sezionatore
---/--- / 63
---/---/---
--- /
---
Quadripolare
1,32
---
---
---
---
---
---
QS0
L1L2L3N.QDPT/NOR..4
QLAP/NOR. C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
1,32
---
---
---
---
---
---
QLAP/NOR. C-2
PRESENZA RETE
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 Ridotto
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
1,32
---
---
---
---
---
---
QS
3
2
QLAP/NOR. C-3
0,6
2,887
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
11,25 / C
0,03 - Cl. A
Monofase L1+N
1,35
---
---
---
---
---
---
Q
Id
3
L1N.QLAP/NOR..0
L1N.QLAP/NOR..3
CBD.45.6.T
Utenza generica QLAP/NOR. C-4
QLAP/NOR. C-4
ORDINARIA
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,66
FG16OM16
12
143/2M_3A/30/0,7
0,700
1(3G1,5)
15
K4
L1N.QLAP/NOR..3
CBD.47.8.T
Utenza generica QLAP/NOR. C-5
QLAP/NOR. C-5
EMERGENZA
0,1
0,481
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,41
FG16OM16
12
143/2M_3A/30/0,7
0,700
1(3G1,5)
15
A
L2N.QLAP/NOR..6
CBD.49.10.T
Utenza generica QLAP/NOR. C-6
QLAP/NOR. C-6
BANCO 1
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
2,45
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
6
L2N.QLAP/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
15 16
AL FG 16DAL FG 14
uni004015UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO AREA PROCESSISEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 5,488 kA - Id: 0,3 AA
L3N.QLAP/NOR..7
CBD.411.12.T
Utenza generica QLAP/NOR. C-7
QLAP/NOR. C-7
BANCO 2
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
2,45
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
7
L3N.QLAP/NOR..0
L1N.QLAP/NOR..8
CBD.413.14.T
Utenza generica QLAP/NOR. C-8
QLAP/NOR. C-8
BANCO 3
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
2,45
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
8
L1N.QLAP/NOR..0
L2N.QLAP/NOR..9
CBD.415.16.T
Utenza generica QLAP/NOR. C-9
QLAP/NOR. C-9
BANCO 4
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
2,45
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
9
L2N.QLAP/NOR..0
L3N.QLAP/NOR..10
CBD.417.18.T
Utenza generica QLAP/NOR. C-10
QLAP/NOR. C-10
BANCO 5
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
2,45
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
10
L3N.QLAP/NOR..0
L1N.QLAP/NOR..11
CBD.419.20.T
Utenza generica QLAP/NOR. C-11
QLAP/NOR. C-11
PRESE DI
SERVIZIO
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
2,5
FG16OM16
10
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
11
L1N.QLAP/NOR..0
L2N.QLAP/NOR..12
CBD.21.22.T
Utenza generica QLAP/NOR. C-12
QLAP/NOR. C-12
AUSILIARI
0,2
0,962
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
1,32
---
---
---
---
---
---
Q
Id
12
L2N.QLAP/NOR..0
A
L3N.QLAP/NOR..13
CBD.23.24.T
QLAP/NOR. C-13
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
1,32
---
---
---
---
---
---
Q
Id
13
L3N.QLAP/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
16 17
AL FG 17DAL FG 15
uni004016UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO AREA PROCESSISEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 5,488 kA - Id: 0,3 AA
L1N.QLAP/NOR..14
CBD.25.26.T
QLAP/NOR. C-14
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
1,32
---
---
---
---
---
---
Q
Id
14
L1N.QLAP/NOR..0
L2N.QLAP/NOR..15
CBD.27.28.T
QLAP/NOR. C-15
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L2+N
1,32
---
---
---
---
---
---
Q
Id
15
L2N.QLAP/NOR..0
L3N.QLAP/NOR..16
CBD.29.30.T
QLAP/NOR. C-16
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L3+N
1,32
---
---
---
---
---
---
Q
Id
16
L3N.QLAP/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLAP/PR.
QLAP.PR
17 18
AL FG 18
uni004017UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO AREA PROCESSISEZIONE PRIVILEGIATASchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 2,248 kA - Id: 0,3 A
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QLAP.PR
Quadripolare2,26400
504,5---
QLAP/PR.
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
UPS-PTUPS-PT C-2
1(5G6)15
40050
QuadripolareCBD.10
1.2.3.4.T
QLAP.PR C-0
GENERALE
SEZ. PRIVILEGIATA
15
29
0,9
100
SIEMENS
5TL14400
Esecuzione Fissa
Sezionatore
---/--- / 40
---/---/---
--- /
---
Quadripolare
2,29
---
---
---
---
---
---
QS0
L1L2L3N.UPS-PT.2
QLAP.PR C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
2,29
---
---
---
---
---
---
QLAP.PR C-2
PRESENZA RETE
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 Ridotto
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
2,29
---
---
---
---
---
---
QS
3
2
L1N.QLAP.PR.3
CBD.45.6.T
Utenza generica QLAP.PR C-3
QLAP.PR C-3
BANCO 1
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
3,42
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
3
L1N.QLAP.PR.0
L2N.QLAP.PR.4
CBD.47.8.T
Utenza generica QLAP.PR C-4
QLAP.PR C-4
BANCO 2
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
3,42
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
4
L2N.QLAP.PR.0
L3N.QLAP.PR.5
CBD.49.10.T
Utenza generica QLAP.PR C-5
QLAP.PR C-5
BANCO 3
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
3,42
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
5
L3N.QLAP.PR.0
A
L1N.QLAP.PR.6
CBD.411.12.T
Utenza generica QLAP.PR C-6
QLAP.PR C-6
BANCO 4
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L1+N
3,42
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
6
L1N.QLAP.PR.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QLAP/PR.
QLAP.PR
18 19
AL FG 19DAL FG 17
uni004018UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO AREA PROCESSISEZIONE PRIVILEGIATASchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 2,248 kA - Id: 0,3 AA
L2N.QLAP.PR.7
CBD.413.14.T
Utenza generica QLAP.PR C-7
QLAP.PR C-7
BANCO 5
3
14
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L2+N
3,42
FG16OM16
10
143/2M_3A/30/0,7
0,700
1(3G2,5)
21
Q
Id
7
L2N.QLAP.PR.0
L3N.QLAP.PR.8
CBD.15.16.T
QLAP.PR C-8
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
2,29
---
---
---
---
---
---
Q
Id
8
L3N.QLAP.PR.0
L1N.QLAP.PR.9
CBD.17.18.T
QLAP.PR C-9
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L1+N
2,29
---
---
---
---
---
---
Q
Id
9
L1N.QLAP.PR.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
UPS ESCLUSO DALLA FORNITURA E POSA IN OPERA
23/0
1/20
18
IEE-02-18
UPS-PT
UPS-PT
19 20
AL FG 20
uni005019UNIVERSITÁ SAPIENZA
ROMA
UPS-PT
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 4,439 kA - Id: 0,3 A
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: UPS-PT
Quadripolare4,439
400
504,5---
UPS-PT
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
QDPT/NOR.QDPT/NOR. C-5
1(5G10)15
40050
QuadripolareCBD.16
1.2.3.4.T
UPS-PT C-0
L1L2L3N.UPS-PT.1
CBD.65.6.7.8.TQLT/PR
UPS-PT C-1
ALIM. SEZ. PRIVILEGIATA
QLT
9
14
0,9
100
SIEMENS
5SL44257
Esecuzione Fissa
MagnetoTermico
---/--- / 25
---/---/250
10 / C
---
Quadripolare
2,07
FG16OM16
15
143/3M13_/30/0,72
0,720
1(5G4)
30
Q1
L1L2L3N.UPS-PT.2
CBD.109.10.11.12.T
QLAP.PR
UPS-PT C-2
ALIMENTAZ. SEZ. PRIV.
QLAP
15
29
0,9
100
SIEMENS
5SL44327
Esecuzione Fissa
MagnetoTermico
---/--- / 32
---/---/320
10 / C
---
Quadripolare
2,28
FG16OM16
15
143/3M13_/30/0,72
0,720
1(5G6)
39
Q2
L1L2L3N.UPS-PT.3
CBD.613.14.15.16.T
QDPT/PR.
UPS-PT C-3
ALIMENTAZIONE SEZ. PRIV.
QDPT
4
9,623
0,9
100
SIEMENS
5SL44257
Esecuzione Fissa
MagnetoTermico
---/--- / 25
---/---/250
10 / C
---
Quadripolare
1,9
FG16OM16
15
143/3M13_/30/0,72
0,720
1(5G4)
30
Q3
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
20 21
AL FG 21
uni006020UNIVERSITÁ SAPIENZA
ROMA
QUADRO P1SEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 8,135 kA
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QDP1/NOR.
Quadripolare8,257
400
5010---
QDP1/NOR.
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
QGENQGEN C-2
1(5G25)15
40050
QuadripolareCBD.35
1.2.3.4.T
QDP1/NOR. C-0
GENERALE SEZ.
NORMALE
25
42
0,9
100
SIEMENS
5TL16631
Esecuzione Fissa
Sezionatore
---/--- / 63
---/---/---
--- /
---
Quadripolare
0,91
---
---
---
---
---
---
QS0
L1L2L3N.QGEN.2
QDP1/NOR. C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
0,91
---
---
---
---
---
---
QDP1/NOR. C-2
PRESENZA RETE
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 Ridotto
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
0,91
---
---
---
---
---
---
QS
3
2
L1L2L3N.QDP1/NOR..3
CBD.65.6.7.8.TUPS-P1
QDP1/NOR. C-3
ALIMENTAZIONE UPS
PIANO 1
14
22
0,9
100
SIEMENS
5SY64327+5SM26458
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 32
---/---/320
15 / C
0,3 - Cl. A S
Quadripolare
1,66
FG16OM16
15
143/3M13_/30/0,8
0,800
1(5G4)
34
Q3
L1L2L3N.QDP1/NOR..0
Id
QDP1/NOR. C-4
GENERALE ILLUMINAZIONE
CORRIDOIO
0,8
3,849
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
11,25 / C
0,03 - Cl. A
Monofase L3+N
0,95
---
---
---
---
---
---
Q
Id
4
L3N.QDP1/NOR..0
L3N.QDP1/NOR..4
CBD.49.10.T
Utenza generica QDP1/NOR. C-5
QDP1/NOR. C-5
ORDINARIA
CORRIDOIO
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L3+N
1,47
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
K5
AB
L3N.QDP1/NOR..4
CBD.411.12.T
Utenza generica QDP1/NOR. C-6
QDP1/NOR. C-6
ORDINARIA
DISIMPEGNO
0,2
0,962
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L3+N
1,16
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
K6
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
21 22
AL FG 22DAL FG 20
uni006021UNIVERSITÁ SAPIENZA
ROMA
QUADRO P1SEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 8,135 kAAB
L3N.QDP1/NOR..4
CBD.413.14.T
Utenza generica QDP1/NOR. C-7
QDP1/NOR. C-7
EMERGENZA
0,1
0,481
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L3+N
1,05
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
QDP1/NOR. C-8
GENERALE ILLUMINAZIONE
UFFICI E INFORMATICA
0,8
3,849
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
11,25 / C
0,03 - Cl. A
Monofase L1+N
0,95
---
---
---
---
---
---
Q
Id
8
L1N.QDP1/NOR..0
L1N.QDP1/NOR..8
CBD.415.16.T
Utenza generica QDP1/NOR. C-9
QDP1/NOR. C-9
ORDINARIA
UFFICIO 1
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,47
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
K9
L1N.QDP1/NOR..8
CBD.417.18.T
Utenza generica QDP1/NOR. C-10
QDP1/NOR. C-10
ORDINARIA UFF.2 E
INFORMATICA
0,2
0,962
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,16
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
L1N.QDP1/NOR..8
CBD.419.20.T
Utenza generica QDP1/NOR. C-11
QDP1/NOR. C-11
EMERGENZA
0,1
0,481
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L1+N
1,05
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
QDP1/NOR. C-12
GENERALE ILLUMINAZIONE
RIUNIONI E SUPP. TEC.
0,8
3,849
0,9
100
SIEMENS
5SU13537KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
11,25 / C
0,03 - Cl. A
Monofase L3+N
0,95
---
---
---
---
---
---
Q
Id
12
L3N.QDP1/NOR..0
AB
L3N.QDP1/NOR..12
CBD.421.22.T
Utenza generica QDP1/NOR. C-13
QDP1/NOR. C-13
ORDINARIA
RIUNIONI
0,5
2,406
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L3+N
1,47
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
K13
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
22 23
AL FG 23DAL FG 21
uni006022UNIVERSITÁ SAPIENZA
ROMA
QUADRO P1SEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 8,135 kAAB
L3N.QDP1/NOR..12
CBD.423.24.T
Utenza generica QDP1/NOR. C-14
QDP1/NOR. C-14
ORDINARIA SUPPORTO
TECNICO
0,2
0,962
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L3+N
1,16
FG16OM16
20
143/3M13_/30/0,72
0,720
1(3G1,5)
19
L3N.QDP1/NOR..12
CBD.425.26.T
Utenza generica QDP1/NOR. C-15
QDP1/NOR. C-15
EMERGENZA
0,1
0,481
0,9
100
---
---
---
No Protezione
---/--- / ---
---/---/---
--- / ---
---
Monofase L3+N
1,08
FG16OM16
25
143/3M13_/30/0,72
0,720
1(3G1,5)
19
L1N.QDP1/NOR..16
CBD.427.28.T
Utenza generica QDP1/NOR. C-16
QDP1/NOR. C-16
FM FAN COIL
RECUPERATORE
1,5
7,217
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L1+N
1,43
FG16OM16
10
143/3M13_/30/0,72
0,720
1(3G2,5)
26
Q
Id
16
L1N.QDP1/NOR..0
L2N.QDP1/NOR..17
CBD.429.30.T
Utenza generica QDP1/NOR. C-17
QDP1/NOR. C-17
RACK
DATI
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L2+N
1,3
FG16OM16
5
143/3M13_/30/0,72
0,720
1(3G2,5)
26
Q
Id
17
L2N.QDP1/NOR..0
L3N.QDP1/NOR..18
CBD.431.32.T
Utenza generica QDP1/NOR. C-18
QDP1/NOR. C-18
PRESE
DI SERVIZIO
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L3+N
1,97
FG16OM16
15
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
18
L3N.QDP1/NOR..0
L1N.QDP1/NOR..19
CBD.433.34.T
Utenza generica QDP1/NOR. C-19
QDP1/NOR. C-19
FM INFORMATICA
E UFFICI
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L1+N
1,31
FG16OM16
5
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
19
L1N.QDP1/NOR..0
A
L2N.QDP1/NOR..20
CBD.435.36.T
Utenza generica QDP1/NOR. C-20
QDP1/NOR. C-20
FM RIUNIONI
E SUPP. TECNICO
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L2+N
1,31
FG16OM16
5
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
20
L2N.QDP1/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
23 24
AL FG 24DAL FG 22
uni006023UNIVERSITÁ SAPIENZA
ROMA
QUADRO P1SEZIONE NORMALESchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 8,135 kAA
L3N.QDP1/NOR..21
CBD.37.38.T
QDP1/NOR. C-21
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
0,91
---
---
---
---
---
---
Q
Id
21
L3N.QDP1/NOR..0
L1N.QDP1/NOR..22
CBD.39.40.T
QDP1/NOR. C-22
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L1+N
0,91
---
---
---
---
---
---
Q
Id
22
L1N.QDP1/NOR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QDP1/PR.
QDP1/PR.
24 25
AL FG 25
uni006024UNIVERSITÁ SAPIENZA
ROMA
QUADRO P1SEZIONE PRIVILEGIATASchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 1,29 kA - Id: 0,3 A
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QDP1/PR.
Quadripolare1,295
400
504,5---
QDP1/PR.
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
UPS-P1UPS-P1 C-1
1(5G4)15
40050
QuadripolareCBD.6
1.2.3.4.T
QDP1/PR. C-0
GENERALE SEZ.
PRIVILEGIATA
10
19
0,9
100
SIEMENS
5TL14320
Esecuzione Fissa
Sezionatore
---/--- / 32
---/---/---
--- /
---
Quadripolare
2,33
---
---
---
---
---
---
QS0
L1L2L3N.UPS-P1.1
QDP1/PR. C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
2,33
---
---
---
---
---
---
QDP1/PR. C-2
PRESENZA RETE
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 Ridotto
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
2,33
---
---
---
---
---
---
QS
3
2
L1N.QDP1/PR..3
CBD.45.6.T
Utenza generica QDP1/PR. C-3
QDP1/PR. C-3
FM INFORMATICA
E UFFICI
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L1+N
2,72
FG16OM16
5
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
3
L1N.QDP1/PR..0
L2N.QDP1/PR..4
CBD.47.8.T
Utenza generica QDP1/PR. C-4
QDP1/PR. C-4
FM INFORMATICA
E UFFICI
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L2+N
2,72
FG16OM16
5
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
4
L2N.QDP1/PR..0
L3N.QDP1/PR..5
CBD.49.10.T
Utenza generica QDP1/PR. C-5
QDP1/PR. C-5
FM UFFICIO
1
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L3+N
2,72
FG16OM16
5
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
5
L3N.QDP1/PR..0
A
L1N.QDP1/PR..6
CBD.411.12.T
Utenza generica QDP1/PR. C-6
QDP1/PR. C-6
FM UFFICIO
2
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L1+N
2,72
FG16OM16
5
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
6
L1N.QDP1/PR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18
QDP1/PR.
QDP1/PR.
25 26
AL FG 26DAL FG 24
uni006025UNIVERSITÁ SAPIENZA
ROMA
QUADRO P1SEZIONE PRIVILEGIATASchema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 1,29 kA - Id: 0,3 AA
L2N.QDP1/PR..7
CBD.413.14.T
Utenza generica QDP1/PR. C-7
QDP1/PR. C-7
FM SUPPORTO
TECNICO
2
9,623
0,9
100
SIEMENS
5SU13537KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
15 / C
0,03 - Cl. A
Monofase L2+N
2,72
FG16OM16
5
143/1M__2/30/0,7
0,700
1(3G2,5)
18
Q
Id
7
L2N.QDP1/PR..0
L3N.QDP1/PR..8
CBD.15.16.T
QDP1/PR. C-8
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
2,33
---
---
---
---
---
---
Q
Id
8
L3N.QDP1/PR..0
L1N.QDP1/PR..9
CBD.17.18.T
QDP1/PR. C-9
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L1+N
2,33
---
---
---
---
---
---
Q
Id
9
L1N.QDP1/PR..0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
FORNITURA E POSA IN OPERA UPS ESCLUSA DAL'APPALTO
23/0
1/20
18
IEE-02-18
UPS-P1
UPS-P1
26 27
AL FG 27
uni007026UNIVERSITÁ SAPIENZA
ROMA
UPS P1
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 2,278 kA - Id: 0,3 A
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: UPS-P1
Quadripolare2,278
400
504,5---
UPS-P1
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
QDP1/NOR.QDP1/NOR. C-3
1(5G4)15
40050
QuadripolareCBD.6
1.2.3.4.T
UPS-P1 C-0
L1L2L3N.UPS-P1.1
CBD.65.6.7.8.T
QDP1/PR.
UPS-P1 C-1
10
19
0,9
100
SIEMENS
5SL44257
Esecuzione Fissa
MagnetoTermico
---/--- / 25
---/---/250
10 / C
---
Quadripolare
2,32
FG16OM16
15
143/3M13_/30/0,72
0,720
1(5G4)
30
Q1
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18QCT
27 28
AL FG 28
uni008027UNIVERSITÁ SAPIENZA
ROMA
QUADRO CENTRALE TERMICA
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,388 kA
Tensione di isolamento nominale [V]:
Corrente ammissibile 1 s [kA]:Frequenza [Hz]:
Grado di protezione IP:Codice:
Tensione nominale di impiego [V]:Ik Max [kA]:Alimentazione:Prefisso quadro: QCT
Quadripolare9,407
400
5010---
Cavo [mm²]:
Tensione [V]:
Polarita':
Lunghezza [m]:
Partenza:Da Quadro:
Tipo morsetto:Numerazione morsetto:
Frequenza [Hz]:
QGENQGEN C-3
3(1x95)+(1x50)+(1PE50)30
40050
Quadripolare
QCT C-0
GENERALE
QCT
107
171
0,9
100
SIEMENS
3KA71224AA00
Esecuzione Fissa
Sezionatore
---/--- / 200
---/---/---
--- /
---
Quadripolare
1,23
---
---
---
---
---
---
QS0
L1L2L3N.QGEN.3
QCT C-1
SPD
0
0
---
100
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Esecuzione Fissa
Limitatore SPD
---/--- / 0
---/---/---
25 /
---
Quadripolare
1,23
---
---
---
---
---
---
QCT C-2
0
0
---
100
SIEMENS
3NW6 Gr. 10x38 SEGN.
Esecuzione Fissa
Fusibile
---/--- / 2
---/---/4,9
100 / gL
---
Quadripolare
1,23
---
---
---
---
---
---
F 2
L1L2L3N.QCT.0
L1
L2
L3
V
V
V
L1L2L3N.QCT.3
CBD.505.6.7.8.T
Utenza generica QCT C-3
QCT C-3
GRUPPO
FRIGO
60
96
0,9
100
SIEMENS
3VA11 L/T TM210 FTFM 3R
Esecuzione Fissa
MagnetoTermico
---/--- / 125
---/---/1 250
25 / N.C.
---
Quadripolare
2,27
FG16M16/H07Z1-K_2 PE
40
143/2U32_/30/1
1,000
4(1x35)+(1PE35)
144
Q3
L1L2L3N.QCT.0
L1L2L3N.QCT.4
CBD.359.10.11.12.T
Utenza generica QCT C-4
QCT C-4
UTA 1
38
61
0,9
100
SIEMENS
3VA11 L/T TM220 ATFM 3RN/2
Esecuzione Fissa
MagnetoTermico
100/70 / 80
---/---/1 000
25 / N.C.
---
Quadripolare
2,16
FG16M16/H07Z1-K_2 PE
40
143/2U32_/30/0,7
0,700
3(1x25)+(1x16)+(1PE16)
82
Q4
L1L2L3N.QCT.0
QCT C-5
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q5
L1L2L3N.QCT.0
AB
L1L2L3.QCT.6
CBD.413.14.15.T
Utenza generica QCT C-6
QCT C-6
EXT.02
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K6
L1L2L3.QCT.5
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18QCT
28 29
AL FG 29DAL FG 27
uni008028UNIVERSITÁ SAPIENZA
ROMA
QUADRO CENTRALE TERMICA
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAA
QCT C-7
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q7
L1L2L3N.QCT.0
L1L2L3.QCT.8
CBD.416.17.18.T
Utenza generica QCT C-8
QCT C-8
EXT.02
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K8
L1L2L3.QCT.7
QCT C-9
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q9
L1L2L3N.QCT.0
L1L2L3.QCT.10
CBD.419.20.21.T
Utenza generica QCT C-10
QCT C-10
EXT.02
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K10
L1L2L3.QCT.9
QCT C-11
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q11
L1L2L3N.QCT.0
L1L2L3.QCT.12
CBD.422.23.24.T
Utenza generica QCT C-12
QCT C-12
EXT.03
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K12
L1L2L3.QCT.11
A
QCT C-13
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q13
L1L2L3N.QCT.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18QCT
29 30
AL FG 30DAL FG 28
uni008029UNIVERSITÁ SAPIENZA
ROMA
QUADRO CENTRALE TERMICA
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAAB
L1L2L3.QCT.14
CBD.425.26.27.T
Utenza generica QCT C-14
QCT C-14
EXT.04
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K14
L1L2L3.QCT.13
QCT C-15
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q15
L1L2L3N.QCT.0
L1L2L3.QCT.16
CBD.428.29.30.T
Utenza generica QCT C-16
QCT C-16
EXT.05
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K16
L1L2L3.QCT.15
QCT C-17
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q17
L1L2L3N.QCT.0
L1L2L3.QCT.18
CBD.431.32.33.T
Utenza generica QCT C-18
QCT C-18
EXT.06
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K18
L1L2L3.QCT.17
QCT C-19
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q19
L1L2L3N.QCT.0
AB
L1L2L3.QCT.20
CBD.434.35.36.T
Utenza generica QCT C-20
QCT C-20
EXT.07
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K20
L1L2L3.QCT.19
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18QCT
30 31
AL FG 31DAL FG 29
uni008030UNIVERSITÁ SAPIENZA
ROMA
QUADRO CENTRALE TERMICA
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAA
QCT C-21
0,3
0,481
0,9
100
SIEMENS
3RV20110GA15
Esecuzione Fissa
MagnetoTermico
0,63/0,45 / 0,63
---/---/8
100 / N.C.
---
Quadripolare
2,02
---
---
---
---
---
---
Q21
L1L2L3N.QCT.0
L1L2L3.QCT.22
CBD.437.38.39.T
Utenza generica QCT C-22
QCT C-22
EXT.08
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
2,06
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K22
L1L2L3.QCT.21
QCT C-23
1,55
2,486
0,9
100
SIEMENS
3RV20111DA10
Esecuzione Fissa
MagnetoTermico
3,2/2,2 / 3,2
---/---/40
100 / N.C.
---
Quadripolare
1,42
---
---
---
---
---
---
Q23
L1L2L3N.QCT.0
L1L2L3.QCT.24
CBD.440.41.42.T
Utenza generica QCT C-24
QCT C-24
EP.01-A
1,55
2,486
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,64
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K24
L1L2L3.QCT.23
QCT C-25
1,55
2,486
0,9
100
SIEMENS
3RV20111DA10
Esecuzione Fissa
MagnetoTermico
3,2/2,2 / 2,5
---/---/40
100 / N.C.
---
Quadripolare
1,42
---
---
---
---
---
---
Q25
L1L2L3N.QCT.0
L1L2L3.QCT.26
CBD.443.44.45.T
Utenza generica QCT C-26
QCT C-26
EP.01-B
1,55
2,486
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,64
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K26
L1L2L3.QCT.25
A
QCT C-27
1,37
2,197
0,9
100
SIEMENS
3RV20111DA10
Esecuzione Fissa
MagnetoTermico
3,2/2,2 / 2,2
---/---/40
100 / N.C.
---
Quadripolare
1,4
---
---
---
---
---
---
Q27
L1L2L3N.QCT.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18QCT
31 32
AL FG 32DAL FG 30
uni008031UNIVERSITÁ SAPIENZA
ROMA
QUADRO CENTRALE TERMICA
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAAB
L1L2L3.QCT.28
CBD.446.47.48.T
Utenza generica QCT C-28
QCT C-28
EP.02-A
1,37
2,197
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,59
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K28
L1L2L3.QCT.27
QCT C-29
1,37
2,197
0,9
100
SIEMENS
3RV20111DA10
Esecuzione Fissa
MagnetoTermico
3,2/2,2 / 3,2
---/---/40
100 / N.C.
---
Quadripolare
1,4
---
---
---
---
---
---
Q29
L1L2L3N.QCT.0
L1L2L3.QCT.30
CBD.449.50.51.T
Utenza generica QCT C-30
QCT C-30
EP.02-B
1,37
2,197
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,59
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K30
L1L2L3.QCT.29
QCT C-31
0,56
0,898
0,9
100
SIEMENS
3RV20110KA15
Esecuzione Fissa
MagnetoTermico
1,25/0,9 / 1,25
---/---/15
100 / N.C.
---
Quadripolare
1,61
---
---
---
---
---
---
Q31
L1L2L3N.QCT.0
L1L2L3.QCT.32
CBD.452.53.54.T
Utenza generica QCT C-32
QCT C-32
EP.03-A
0,56
0,898
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,68
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K32
L1L2L3.QCT.31
QCT C-33
0,56
0,898
0,9
100
SIEMENS
3RV20110KA15
Esecuzione Fissa
MagnetoTermico
1,25/0,9 / 1,25
---/---/15
100 / N.C.
---
Quadripolare
1,61
---
---
---
---
---
---
Q33
L1L2L3N.QCT.0
AB
L1L2L3.QCT.34
CBD.455.56.57.T
Utenza generica QCT C-34
QCT C-34
EP.03-B
0,56
0,898
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,68
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K34
L1L2L3.QCT.33
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18QCT
32 33
AL FG 33DAL FG 31
uni008032UNIVERSITÁ SAPIENZA
ROMA
QUADRO CENTRALE TERMICA
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAA
QCT C-35
0,3
0,481
0,9
100
SIEMENS
3RV20110KA15
Esecuzione Fissa
MagnetoTermico
1,25/0,9 / 1,25
---/---/15
100 / N.C.
---
Quadripolare
1,43
---
---
---
---
---
---
Q35
L1L2L3N.QCT.0
L1L2L3.QCT.36
CBD.458.59.60.T
Utenza generica QCT C-36
QCT C-36
EP.04-A
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,48
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K36
L1L2L3.QCT.35
QCT C-37
0,3
0,481
0,9
100
SIEMENS
3RV20110KA15
Esecuzione Fissa
MagnetoTermico
1,25/0,9 / 1,25
---/---/15
100 / N.C.
---
Quadripolare
1,43
---
---
---
---
---
---
Q37
L1L2L3N.QCT.0
L1L2L3.QCT.38
CBD.461.62.63.T
Utenza generica QCT C-38
QCT C-38
EP.04-B
0,3
0,481
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,48
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K38
L1L2L3.QCT.37
QCT C-39
2,06
3,304
0,9
100
SIEMENS
3RV20111EA10
Esecuzione Fissa
MagnetoTermico
4/2,8 / 4
---/---/48
100 / N.C.
---
Quadripolare
1,4
---
---
---
---
---
---
Q39
L1L2L3N.QCT.0
L1L2L3.QCT.40
CBD.464.65.66.T
Utenza generica QCT C-40
QCT C-40
EP.05-A
2,06
3,304
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,69
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K40
L1L2L3.QCT.39
A
QCT C-41
2,06
3,304
0,9
100
SIEMENS
3RV20111EA10
Esecuzione Fissa
MagnetoTermico
4/2,8 / 4
---/---/48
100 / N.C.
---
Quadripolare
1,4
---
---
---
---
---
---
Q41
L1L2L3N.QCT.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
Sigla utenza
Descrizione
POTENZA CONTEMPORANEA [kW]CORRENTE (Ib) [A]CosFiCOEFF. DI CONTEMPORANEITA' [%]SCHEMA FUNZIONALE
MARCAMODELLOESECUZIONETIPOLOGIA
PROTEZIONE In max/min/Reg. [A]Im max/min/Reg. [A]P.d.I. / Curva [kA]Id max/min/Reg./Classe [A]
DISTRIBUZIONECADUTA DI TENSIONE PERCENTUALE [%]VOLTMETRO / AMPEROMETRO
SIGLALUNGHEZZA [m]POSAK CORRETTIVI (K1,K2,K3,K4)LINEASezione [mmq]Portata (Iz) [A]
23/0
1/20
18
IEE-02-18QCT
33 -
DAL FG 32
uni008033UNIVERSITÁ SAPIENZA
ROMA
QUADRO CENTRALE TERMICA
Schema Unifilare
Dati barratura: 400/230V - 50Hz - Icc = 9,388 kAAB
L1L2L3.QCT.42
CBD.467.68.69.T
Utenza generica QCT C-42
QCT C-42
EP.05-B
2,06
3,304
0,9
100
SIEMENS
3RT20151AB01
Esecuzione Fissa
Contattore
---/--- / 7
---/---/---
--- /
---
Tripolare
1,69
FG16OM16
15
143/2M34A/30/0,38
0,380
1(4G1,5)
7,41
K42
L1L2L3.QCT.41
L3N.QCT.43
CBD.70.71.T
Utenza generica QCT C-43
QCT C-43
AUSILIARI
0,1
0,481
0,9
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
1,24
---
---
---
---
---
---
Q
Id
43
L3N.QCT.0
L3N.QCT.44
CBD.72.73.T
QCT C-44
RISERVA
0
0
---
100
SIEMENS
5SU13547KK16
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 16
---/---/160
10 / C
0,03 - Cl. A
Monofase L3+N
1,23
---
---
---
---
---
---
Q
Id
44
L3N.QCT.0
L1N.QCT.45
CBD.74.75.T
QCT C-45
RISERVA
0
0
---
100
SIEMENS
5SU13547KK10
Esecuzione Fissa
MagnetoTermicoDiff.
---/--- / 10
---/---/100
10 / C
0,03 - Cl. A
Monofase L1+N
1,23
---
---
---
---
---
---
Q
Id
45
L1N.QCT.0
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
1 2aux008001UNIVERSITÁ SAPIENZA
ROMA
SCHEMI AUSILIARI
Nelle pagine seguenti sono riportati gli schemi ausiliari deiquadri elettrici presenti nell'impianto
Progetto INTEGRA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
2 3aux002002UNIVERSITÁ SAPIENZA
ROMASchema AusiliariSEZIONE NORMALEQUADRO PT
RPP
S
10
QDPT/NOR. C-10ORDINARIA CORRIDOIO
E FILTRO
RPP
S
11
QDPT/NOR. C-11ORDINARIA
DISIMPEGNO
RPP
S
14
QDPT/NOR. C-14ORDINARIA
RPP
S
17
QDPT/NOR. C-17ORDINARIA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
3 4aux004003UNIVERSITÁ SAPIENZA
ROMASchema AusiliariSEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI
RPP
S
4
QLAP/NOR. C-4ORDINARIA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
4 - aux006004UNIVERSITÁ SAPIENZA
ROMASchema AusiliariSEZIONE NORMALEQUADRO P1
RPP
S
5
QDP1/NOR. C-5ORDINARIACORRIDOIO
RPP
S
6
QDP1/NOR. C-6ORDINARIA
DISIMPEGNO
RPP
S
9
QDP1/NOR. C-9ORDINARIAUFFICIO 1
RPP
S
13
QDP1/NOR. C-13ORDINARIARIUNIONI
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
1 2mor006001UNIVERSITÁ SAPIENZA
ROMA
MORSETTIERE
Nelle pagine seguenti sono riportati i disegni delle morsettieredi potenza dei Quadri
Progetto INTEGRA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18QGEN
2 3mor001002UNIVERSITÁ SAPIENZA
ROMASchema morsettiera
Quadro Generale EDIFICIO
L1.Q
GEN
.11
CBD.
70L2
.QG
EN.1
2CB
D.70
L3.Q
GEN
.13
CBD.
70N.
QG
EN.1
4CB
D.70
TCB
D.70
ALIM
ENTA
ZIO
NE O
RDIN
ARIA
QUA
DRO
PT
QG
EN C
-1FG
16M
16/H
07Z1
-K_2
PE
3(1
x50)
+(1x
25)+
(1PE
25)
L1.Q
GEN
.25
CBD.
35L2
.QG
EN.2
6CB
D.35
L3.Q
GEN
.27
CBD.
35N.
QG
EN.2
8CB
D.35
TCB
D.35
ALIM
ENTA
ZIO
NE Q
P1Q
GEN
C-2
FG16
OM
16
1(5G
25)
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
3 4mor002003UNIVERSITÁ SAPIENZA
ROMASchema morsettieraSEZIONE NORMALEQUADRO PT
L11
CBD.
70L2
2CB
D.70
L33
CBD.
70N
4CB
D.70
TCB
D.70
Da Q
uadr
o Q
GEN
- Pa
rtenz
a Q
GEN
C-1
QG
EN C
-1FG
16M
16/H
07Z1
-K_2
PE
3(1
x50)
+(1x
25)+
(1PE
25)
L1.Q
DPT/
NOR.
.35
CBD.
16L2
.QDP
T/NO
R..3
6CB
D.16
L3.Q
DPT/
NOR.
.37
CBD.
16N.
QDP
T/NO
R..3
8CB
D.16
TCB
D.16
ALIM
ENTA
ZIO
NE Q
LTQ
DPT/
NOR.
C-3
FG16
OM
16
1(5G
10)
L1.Q
DPT/
NOR.
.49
CBD.
25L2
.QDP
T/NO
R..4
10CB
D.25
L3.Q
DPT/
NOR.
.411
CBD.
25N.
QDP
T/NO
R..4
12CB
D.25
TCB
D.25
ALIM
ENTA
ZIO
NE Q
LAP
QDP
T/NO
R. C
-4FG
16O
M16
1(
5G16
)
L1.Q
DPT/
NOR.
.513
CBD.
16L2
.QDP
T/NO
R..5
14CB
D.16
L3.Q
DPT/
NOR.
.515
CBD.
16N.
QDP
T/NO
R..5
16CB
D.16
TCB
D.16
ALIM
ENTA
ZIO
NE U
PS P
IANO
TER
RAQ
DPT/
NOR.
C-5
FG16
OM
16
1(5G
10)
L1.Q
DPT/
NOR.
.617
CBD.
N.Q
DPT/
NOR.
.618
CBD.
TCB
D.
AUSI
LIAR
I Q
DPT/
NOR.
C-6
---
---
L3.Q
DPT/
NOR.
.719
CBD.
4N.
QDP
T/NO
R..7
20CB
D.4
TCB
D.4
BATT
ERIE
DI P
OST
QDP
T/NO
R. C
-7FG
16O
M16
1(
3G1,
5)
L1.Q
DPT/
NOR.
.821
CBD.
4N.
QDP
T/NO
R..8
22CB
D.4
TCB
D.4
ORD
INAR
IA D
EPO
SITO
QDP
T/NO
R. C
-9FG
16O
M16
1(
3G1,
5)
L1.Q
DPT/
NOR.
.823
CBD.
4N.
QDP
T/NO
R..8
24CB
D.4
TCB
D.4
ORD
INAR
IA C
ORR
IDO
IO E
FIL
TRO
QDP
T/NO
R. C
-10
FG16
OM
16
1(3G
1,5)
L1.Q
DPT/
NOR.
.825
CBD.
4N.
QDP
T/NO
R..8
26CB
D.4
TCB
D.4
ORD
INAR
IA D
ISIM
PEG
NOQ
DPT/
NOR.
C-1
1FG
16O
M16
1(
3G1,
5)
L1.Q
DPT/
NOR.
.827
CBD.
4N.
QDP
T/NO
R..8
28CB
D.4
TCB
D.4
EMER
GEN
ZA
QDP
T/NO
R. C
-12
FG16
OM
16
1(3G
1,5)
L1.Q
DPT/
NOR.
.13
29CB
D.4
N.Q
DPT/
NOR.
.13
30CB
D.4
TCB
D.4
ORD
INAR
IA
QDP
T/NO
R. C
-14
FG16
OM
16
1(3G
1,5)
L1.Q
DPT/
NOR.
.13
31CB
D.4
N.Q
DPT/
NOR.
.13
32CB
D.4
TCB
D.4
EMER
GEN
ZA
QDP
T/NO
R. C
-15
FG16
OM
16
1(3G
1,5)
L2.Q
DPT/
NOR.
.16
33CB
D.4
N.Q
DPT/
NOR.
.16
34CB
D.4
TCB
D.4
ORD
INAR
IA
QDP
T/NO
R. C
-17
FG16
OM
16
1(3G
1,5)
L2.Q
DPT/
NOR.
.16
35CB
D.4
N.Q
DPT/
NOR.
.16
36CB
D.4
TCB
D.4
EMER
GEN
ZA
QDP
T/NO
R. C
-18
FG16
OM
16
1(3G
1,5)
L3.Q
DPT/
NOR.
.19
37CB
D.4
N.Q
DPT/
NOR.
.19
38CB
D.4
TCB
D.4
PRES
E F
RIG
ORI
FERI
QDP
T/NO
R. C
-19
FG16
OM
16
1(3G
2,5)
L1.Q
DPT/
NOR.
.20
39CB
D.4
N.Q
DPT/
NOR.
.20
40CB
D.4
TCB
D.4
PRES
E DI
SER
VIZI
OQ
DPT/
NOR.
C-2
0FG
16O
M16
1(
3G2,
5)
L2.Q
DPT/
NOR.
.21
41CB
D.4
N.Q
DPT/
NOR.
.21
42CB
D.4
TCB
D.4
PRES
E SC
RIVA
NIA
1Q
DPT/
NOR.
C-2
1FG
16O
M16
1(
3G2,
5)
L3.Q
DPT/
NOR.
.22
43CB
D.4
N.Q
DPT/
NOR.
.22
44CB
D.4
TCB
D.4
PRES
E SC
RIVA
NIA
2Q
DPT/
NOR.
C-2
2FG
16O
M16
1(
3G2,
5)
L1.Q
DPT/
NOR.
.23
45CB
D.4
N.Q
DPT/
NOR.
.23
46CB
D.4
TCB
D.4
PRES
E SE
RVIZ
IO S
UPP.
PRO
CESS
IQ
DPT/
NOR.
C-2
3FG
16O
M16
1(
3G2,
5)
L2.Q
DPT/
NOR.
.24
47CB
D.4
N.Q
DPT/
NOR.
.24
48CB
D.4
TCB
D.4
RACK
DAT
IQ
DPT/
NOR.
C-2
4FG
16O
M16
1(
3G2,
5)
L3.Q
DPT/
NOR.
.25
49CB
D.N.
QDP
T/NO
R..2
550
CBD.
TCB
D.
RIS
ERVA
Q
DPT/
NOR.
C-2
5---
---
L1.Q
DPT/
NOR.
.26
51CB
D.N.
QDP
T/NO
R..2
652
CBD.
TCB
D.
RIS
ERVA
Q
DPT/
NOR.
C-2
6---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDPT/PR.
QDPT/PR.
4 5mor002004UNIVERSITÁ SAPIENZA
ROMASchema morsettieraSEZIONE PRIVILEGIATAQUADRO PT
L11
CBD.
6L2
2CB
D.6
L33
CBD.
6N
4CB
D.6
TCB
D.6
Da Q
uadr
o UP
S-PT
- Pa
rtenz
a UP
S-PT
C-3
UPS-
PT C
-3FG
16O
M16
1(
5G4)
L1.Q
DPT/
PR..3
5CB
D.4
N.Q
DPT/
PR..3
6CB
D.4
TCB
D.4
PRES
E SC
RIVA
NIA
1Q
DPT/
PR. C
-3FG
16O
M16
1(
3G2,
5)
L2.Q
DPT/
PR..4
7CB
D.4
N.Q
DPT/
PR..4
8CB
D.4
TCB
D.4
PRES
E SC
RIVA
NIA
2Q
DPT/
PR. C
-4FG
16O
M16
1(
3G2,
5)
L3.Q
DPT/
PR..5
9CB
D.N.
QDP
T/PR
..510
CBD.
TCB
D.
RIS
ERVA
Q
DPT/
PR. C
-5---
---
L1.Q
DPT/
PR..6
11CB
D.N.
QDP
T/PR
..612
CBD.
TCB
D.
RIS
ERVA
Q
DPT/
PR. C
-6---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
5 6mor003005UNIVERSITÁ SAPIENZA
ROMASchema morsettieraSEZIONE NORMALEQUADRO LABORATORIO TECNICO
L11
CBD.
16L2
2CB
D.16
L33
CBD.
16N
4CB
D.16
TCB
D.16
Da Q
uadr
o Q
DPT/
NOR.
- Pa
rtenz
a Q
DPT/
NOR.
C-3
QDP
T/NO
R. C
-3FG
16O
M16
1(
5G10
)
L1.Q
LT/N
OR.
.35
CBD.
4N.
QLT
/NO
R..3
6CB
D.4
TCB
D.4
ORD
INAR
IA
QLT
/NO
R. C
-4FG
16O
M16
1(
3G1,
5)
L1.Q
LT/N
OR.
.37
CBD.
4N.
QLT
/NO
R..3
8CB
D.4
TCB
D.4
EMER
GEN
ZA
QLT
/NO
R. C
-5FG
16O
M16
1(
3G1,
5)
L2.Q
LT/N
OR.
.69
CBD.
4N.
QLT
/NO
R..6
10CB
D.4
TCB
D.4
FRIG
O C
OM
BINA
TOQ
LT/N
OR.
C-6
FG16
OM
16
1(3G
2,5)
L3.Q
LT/N
OR.
.711
CBD.
4N.
QLT
/NO
R..7
12CB
D.4
TCB
D.4
ULTR
ACEN
TRIF
UGA
QLT
/NO
R. C
-7FG
16O
M16
1(
3G2,
5)
L1.Q
LT/N
OR.
.813
CBD.
4N.
QLT
/NO
R..8
14CB
D.4
TCB
D.4
AUTO
CLAV
E PI
CCO
LAQ
LT/N
OR.
C-8
FG16
OM
16
1(3G
2,5)
L2.Q
LT/N
OR.
.915
CBD.
4N.
QLT
/NO
R..9
16CB
D.4
TCB
D.4
INCU
B. P
IAST
REQ
LT/N
OR.
C-9
FG16
OM
16
1(3G
2,5)
L3.Q
LT/N
OR.
.10
17CB
D.4
N.Q
LT/N
OR.
.10
18CB
D.4
TCB
D.4
LIO
FILI
ZZAT
ORE
Q
LT/N
OR.
C-1
0FG
16O
M16
1(
3G2,
5)
L1.Q
LT/N
OR.
.11
19CB
D.4
N.Q
LT/N
OR.
.11
20CB
D.4
TCB
D.4
SIST
PUR
IFIC
. H2O
QLT
/NO
R. C
-11
FG16
OM
16
1(3G
2,5)
L2.Q
LT/N
OR.
.12
21CB
D.4
N.Q
LT/N
OR.
.12
22CB
D.4
TCB
D.4
CABI
NA A
FLU
SSO
LAM
INAR
EQ
LT/N
OR.
C-1
2FG
16O
M16
1(
3G2,
5)
L3.Q
LT/N
OR.
.13
23CB
D.4
N.Q
LT/N
OR.
.13
24CB
D.4
TCB
D.4
AUTO
CLAV
E G
RAND
EQ
LT/N
OR.
C-1
3FG
16O
M16
1(
3G2,
5)
L1.Q
LT/N
OR.
.14
25CB
D.4
N.Q
LT/N
OR.
.14
26CB
D.4
TCB
D.4
BANC
O 1
Q
LT/N
OR.
C-1
4FG
16O
M16
1(
3G2,
5)
L2.Q
LT/N
OR.
.15
27CB
D.4
N.Q
LT/N
OR.
.15
28CB
D.4
TCB
D.4
BANC
O 2
Q
LT/N
OR.
C-1
5FG
16O
M16
1(
3G2,
5)
L3.Q
LT/N
OR.
.16
29CB
D.4
N.Q
LT/N
OR.
.16
30CB
D.4
TCB
D.4
BANC
O 3
Q
LT/N
OR.
C-1
6FG
16O
M16
1(
3G2,
5)
L1.Q
LT/N
OR.
.17
31CB
D.10
L2.Q
LT/N
OR.
.17
32CB
D.10
L3.Q
LT/N
OR.
.17
33CB
D.10
N.Q
LT/N
OR.
.17
34CB
D.10
TCB
D.10
LAVA
VETR
ERIA
Q
LT/N
OR.
C-1
7FG
16O
M16
1(
5G6)
L3.Q
LT/N
OR.
.18
35CB
D.4
N.Q
LT/N
OR.
.18
36CB
D.4
TCB
D.4
PRES
E DI
SER
VIZI
OQ
LT/N
OR.
C-1
8FG
16O
M16
1(
3G2,
5)
L1.Q
LT/N
OR.
.19
37CB
D.N.
QLT
/NO
R..1
938
CBD.
TCB
D.
RIS
ERVA
Q
LT/N
OR.
C-1
9---
---
L2.Q
LT/N
OR.
.20
39CB
D.N.
QLT
/NO
R..2
040
CBD.
TCB
D.
RIS
ERVA
Q
LT/N
OR.
C-2
0---
---
L3.Q
LT/N
OR.
.21
41CB
D.N.
QLT
/NO
R..2
142
CBD.
TCB
D.
RIS
ERVA
Q
LT/N
OR.
C-2
1---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/PR
QLT/PR
6 7mor003006UNIVERSITÁ SAPIENZA
ROMASchema morsettieraSEZIONE PRIVILEGIATAQUADRO LABORATORIO TECNICO
L11
CBD.
6L2
2CB
D.6
L33
CBD.
6N
4CB
D.6
TCB
D.6
Da Q
uadr
o UP
S-PT
- Pa
rtenz
a UP
S-PT
C-1
UPS-
PT C
-1FG
16O
M16
1(
5G4)
L1.Q
LT/P
R.3
5CB
D.4
N.Q
LT/P
R.3
6CB
D.4
TCB
D.4
BANC
O 1
Q
LT/P
R C-
3FG
16O
M16
1(
3G2,
5)
L2.Q
LT/P
R.4
7CB
D.4
N.Q
LT/P
R.4
8CB
D.4
TCB
D.4
BANC
O 2
Q
LT/P
R C-
4FG
16O
M16
1(
3G2,
5)
L3.Q
LT/P
R.5
9CB
D.4
N.Q
LT/P
R.5
10CB
D.4
TCB
D.4
BANC
O 3
Q
LT/P
R C-
5FG
16O
M16
1(
3G2,
5)
L1.Q
LT/P
R.6
11CB
D.N.
QLT
/PR.
612
CBD.
TCB
D.
RIS
ERVA
Q
LT/P
R C-
6---
---
L2.Q
LT/P
R.7
13CB
D.N.
QLT
/PR.
714
CBD.
TCB
D.
RIS
ERVA
Q
LT/P
R C-
7---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
7 8mor004007UNIVERSITÁ SAPIENZA
ROMASchema morsettieraSEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI
L11
CBD.
25L2
2CB
D.25
L33
CBD.
25N
4CB
D.25
TCB
D.25
Da Q
uadr
o Q
DPT/
NOR.
- Pa
rtenz
a Q
DPT/
NOR.
C-4
QDP
T/NO
R. C
-4FG
16O
M16
1(
5G16
)
L1.Q
LAP/
NOR.
.35
CBD.
4N.
QLA
P/NO
R..3
6CB
D.4
TCB
D.4
ORD
INAR
IA
QLA
P/NO
R. C
-4FG
16O
M16
1(
3G1,
5)
L1.Q
LAP/
NOR.
.37
CBD.
4N.
QLA
P/NO
R..3
8CB
D.4
TCB
D.4
EMER
GEN
ZA
QLA
P/NO
R. C
-5FG
16O
M16
1(
3G1,
5)
L2.Q
LAP/
NOR.
.69
CBD.
4N.
QLA
P/NO
R..6
10CB
D.4
TCB
D.4
BANC
O 1
Q
LAP/
NOR.
C-6
FG16
OM
16
1(3G
2,5)
L3.Q
LAP/
NOR.
.711
CBD.
4N.
QLA
P/NO
R..7
12CB
D.4
TCB
D.4
BANC
O 2
Q
LAP/
NOR.
C-7
FG16
OM
16
1(3G
2,5)
L1.Q
LAP/
NOR.
.813
CBD.
4N.
QLA
P/NO
R..8
14CB
D.4
TCB
D.4
BANC
O 3
Q
LAP/
NOR.
C-8
FG16
OM
16
1(3G
2,5)
L2.Q
LAP/
NOR.
.915
CBD.
4N.
QLA
P/NO
R..9
16CB
D.4
TCB
D.4
BANC
O 4
Q
LAP/
NOR.
C-9
FG16
OM
16
1(3G
2,5)
L3.Q
LAP/
NOR.
.10
17CB
D.4
N.Q
LAP/
NOR.
.10
18CB
D.4
TCB
D.4
BANC
O 5
Q
LAP/
NOR.
C-1
0FG
16O
M16
1(
3G2,
5)
L1.Q
LAP/
NOR.
.11
19CB
D.4
N.Q
LAP/
NOR.
.11
20CB
D.4
TCB
D.4
PRES
E DI
SER
VIZI
OQ
LAP/
NOR.
C-1
1FG
16O
M16
1(
3G2,
5)
L2.Q
LAP/
NOR.
.12
21CB
D.N.
QLA
P/NO
R..1
222
CBD.
TCB
D.
AUSI
LIAR
I Q
LAP/
NOR.
C-1
2---
---
L3.Q
LAP/
NOR.
.13
23CB
D.N.
QLA
P/NO
R..1
324
CBD.
TCB
D.
RIS
ERVA
Q
LAP/
NOR.
C-1
3---
---
L1.Q
LAP/
NOR.
.14
25CB
D.N.
QLA
P/NO
R..1
426
CBD.
TCB
D.
RIS
ERVA
Q
LAP/
NOR.
C-1
4---
---
L2.Q
LAP/
NOR.
.15
27CB
D.N.
QLA
P/NO
R..1
528
CBD.
TCB
D.
RIS
ERVA
Q
LAP/
NOR.
C-1
5---
---
L3.Q
LAP/
NOR.
.16
29CB
D.N.
QLA
P/NO
R..1
630
CBD.
TCB
D.
RIS
ERVA
Q
LAP/
NOR.
C-1
6---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/PR.
QLAP.PR
8 9mor004008UNIVERSITÁ SAPIENZA
ROMASchema morsettieraSEZIONE PRIVILEGIATAQUADRO LABORATORIO AREA PROCESSI
L11
CBD.
10L2
2CB
D.10
L33
CBD.
10N
4CB
D.10
TCB
D.10
Da Q
uadr
o UP
S-PT
- Pa
rtenz
a UP
S-PT
C-2
UPS-
PT C
-2FG
16O
M16
1(
5G6)
L1.Q
LAP.
PR.3
5CB
D.4
N.Q
LAP.
PR.3
6CB
D.4
TCB
D.4
BANC
O 1
Q
LAP.
PR C
-3FG
16O
M16
1(
3G2,
5)
L2.Q
LAP.
PR.4
7CB
D.4
N.Q
LAP.
PR.4
8CB
D.4
TCB
D.4
BANC
O 2
Q
LAP.
PR C
-4FG
16O
M16
1(
3G2,
5)
L3.Q
LAP.
PR.5
9CB
D.4
N.Q
LAP.
PR.5
10CB
D.4
TCB
D.4
BANC
O 3
Q
LAP.
PR C
-5FG
16O
M16
1(
3G2,
5)
L1.Q
LAP.
PR.6
11CB
D.4
N.Q
LAP.
PR.6
12CB
D.4
TCB
D.4
BANC
O 4
Q
LAP.
PR C
-6FG
16O
M16
1(
3G2,
5)
L2.Q
LAP.
PR.7
13CB
D.4
N.Q
LAP.
PR.7
14CB
D.4
TCB
D.4
BANC
O 5
Q
LAP.
PR C
-7FG
16O
M16
1(
3G2,
5)
L3.Q
LAP.
PR.8
15CB
D.N.
QLA
P.PR
.816
CBD.
TCB
D.
RIS
ERVA
Q
LAP.
PR C
-8---
---
L1.Q
LAP.
PR.9
17CB
D.N.
QLA
P.PR
.918
CBD.
TCB
D.
RIS
ERVA
Q
LAP.
PR C
-9---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: UPS ESCLUSO DALLA FORNITURA E POSA IN OPERA
23/0
1/20
18
IEE-02-18
UPS-PT
UPS-PT
9 10mor005009UNIVERSITÁ SAPIENZA
ROMASchema morsettiera
UPS-PT
1CB
D.16
2CB
D.16
3CB
D.16
4CB
D.16
TCB
D.16
Da Q
uadr
o Q
DPT/
NOR.
- Pa
rtenz
a Q
DPT/
NOR.
C-5
QDP
T/NO
R. C
-5FG
16O
M16
1(
5G10
)
L1.U
PS-P
T.1
5CB
D.6
L2.U
PS-P
T.1
6CB
D.6
L3.U
PS-P
T.1
7CB
D.6
N.UP
S-PT
.18
CBD.
6T
CBD.
6
ALIM
. SEZ
. PRI
VILE
GIA
TA Q
LTUP
S-PT
C-1
FG16
OM
16
1(5G
4)
L1.U
PS-P
T.2
9CB
D.10
L2.U
PS-P
T.2
10CB
D.10
L3.U
PS-P
T.2
11CB
D.10
N.UP
S-PT
.212
CBD.
10T
CBD.
10
ALIM
ENTA
Z. S
EZ. P
RIV.
QLA
PUP
S-PT
C-2
FG16
OM
16
1(5G
6)
L1.U
PS-P
T.3
13CB
D.6
L2.U
PS-P
T.3
14CB
D.6
L3.U
PS-P
T.3
15CB
D.6
N.UP
S-PT
.316
CBD.
6T
CBD.
6
ALIM
ENTA
ZIO
NE S
EZ. P
RIV.
QDP
TUP
S-PT
C-3
FG16
OM
16
1(5G
4)
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
10 11mor006010UNIVERSITÁ SAPIENZA
ROMASchema morsettieraSEZIONE NORMALEQUADRO P1
L11
CBD.
35L2
2CB
D.35
L33
CBD.
35N
4CB
D.35
TCB
D.35
Da Q
uadr
o Q
GEN
- Pa
rtenz
a Q
GEN
C-2
QG
EN C
-2FG
16O
M16
1(
5G25
)
L1.Q
DP1/
NOR.
.35
CBD.
6L2
.QDP
1/NO
R..3
6CB
D.6
L3.Q
DP1/
NOR.
.37
CBD.
6N.
QDP
1/NO
R..3
8CB
D.6
TCB
D.6
ALIM
ENTA
ZIO
NE U
PS P
IANO
1Q
DP1/
NOR.
C-3
FG16
OM
16
1(5G
4)
L3.Q
DP1/
NOR.
.49
CBD.
4N.
QDP
1/NO
R..4
10CB
D.4
TCB
D.4
ORD
INAR
IA C
ORR
IDO
IOQ
DP1/
NOR.
C-5
FG16
OM
16
1(3G
1,5)
L3.Q
DP1/
NOR.
.411
CBD.
4N.
QDP
1/NO
R..4
12CB
D.4
TCB
D.4
ORD
INAR
IA D
ISIM
PEG
NOQ
DP1/
NOR.
C-6
FG16
OM
16
1(3G
1,5)
L3.Q
DP1/
NOR.
.413
CBD.
4N.
QDP
1/NO
R..4
14CB
D.4
TCB
D.4
EMER
GEN
ZA
QDP
1/NO
R. C
-7FG
16O
M16
1(
3G1,
5)
L1.Q
DP1/
NOR.
.815
CBD.
4N.
QDP
1/NO
R..8
16CB
D.4
TCB
D.4
ORD
INAR
IA U
FFIC
IO 1
QDP
1/NO
R. C
-9FG
16O
M16
1(
3G1,
5)
L1.Q
DP1/
NOR.
.817
CBD.
4N.
QDP
1/NO
R..8
18CB
D.4
TCB
D.4
ORD
INAR
IA U
FF.2
E I
NFO
RMAT
ICA
QDP
1/NO
R. C
-10
FG16
OM
16
1(3G
1,5)
L1.Q
DP1/
NOR.
.819
CBD.
4N.
QDP
1/NO
R..8
20CB
D.4
TCB
D.4
EMER
GEN
ZA
QDP
1/NO
R. C
-11
FG16
OM
16
1(3G
1,5)
L3.Q
DP1/
NOR.
.12
21CB
D.4
N.Q
DP1/
NOR.
.12
22CB
D.4
TCB
D.4
ORD
INAR
IA R
IUNI
ONI
QDP
1/NO
R. C
-13
FG16
OM
16
1(3G
1,5)
L3.Q
DP1/
NOR.
.12
23CB
D.4
N.Q
DP1/
NOR.
.12
24CB
D.4
TCB
D.4
ORD
INAR
IA S
UPPO
RTO
TEC
NICO
QDP
1/NO
R. C
-14
FG16
OM
16
1(3G
1,5)
L3.Q
DP1/
NOR.
.12
25CB
D.4
N.Q
DP1/
NOR.
.12
26CB
D.4
TCB
D.4
EMER
GEN
ZA
QDP
1/NO
R. C
-15
FG16
OM
16
1(3G
1,5)
L1.Q
DP1/
NOR.
.16
27CB
D.4
N.Q
DP1/
NOR.
.16
28CB
D.4
TCB
D.4
FM F
AN C
OIL
REC
UPER
ATO
REQ
DP1/
NOR.
C-1
6FG
16O
M16
1(
3G2,
5)
L2.Q
DP1/
NOR.
.17
29CB
D.4
N.Q
DP1/
NOR.
.17
30CB
D.4
TCB
D.4
RACK
DAT
IQ
DP1/
NOR.
C-1
7FG
16O
M16
1(
3G2,
5)
L3.Q
DP1/
NOR.
.18
31CB
D.4
N.Q
DP1/
NOR.
.18
32CB
D.4
TCB
D.4
PRES
E DI
SER
VIZI
OQ
DP1/
NOR.
C-1
8FG
16O
M16
1(
3G2,
5)
L1.Q
DP1/
NOR.
.19
33CB
D.4
N.Q
DP1/
NOR.
.19
34CB
D.4
TCB
D.4
FM IN
FORM
ATIC
A E
UFFI
CIQ
DP1/
NOR.
C-1
9FG
16O
M16
1(
3G2,
5)
L2.Q
DP1/
NOR.
.20
35CB
D.4
N.Q
DP1/
NOR.
.20
36CB
D.4
TCB
D.4
FM R
IUNI
ONI
E S
UPP.
TEC
NICO
QDP
1/NO
R. C
-20
FG16
OM
16
1(3G
2,5)
L3.Q
DP1/
NOR.
.21
37CB
D.N.
QDP
1/NO
R..2
138
CBD.
TCB
D.
RIS
ERVA
Q
DP1/
NOR.
C-2
1---
---
L1.Q
DP1/
NOR.
.22
39CB
D.N.
QDP
1/NO
R..2
240
CBD.
TCB
D.
RIS
ERVA
Q
DP1/
NOR.
C-2
2---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/PR.
QDP1/PR.
11 12mor006011UNIVERSITÁ SAPIENZA
ROMASchema morsettieraSEZIONE PRIVILEGIATAQUADRO P1
L11
CBD.
6L2
2CB
D.6
L33
CBD.
6N
4CB
D.6
TCB
D.6
Da Q
uadr
o UP
S-P1
- Pa
rtenz
a UP
S-P1
C-1
UPS-
P1 C
-1FG
16O
M16
1(
5G4)
L1.Q
DP1/
PR..3
5CB
D.4
N.Q
DP1/
PR..3
6CB
D.4
TCB
D.4
FM IN
FORM
ATIC
A E
UFFI
CIQ
DP1/
PR. C
-3FG
16O
M16
1(
3G2,
5)
L2.Q
DP1/
PR..4
7CB
D.4
N.Q
DP1/
PR..4
8CB
D.4
TCB
D.4
FM IN
FORM
ATIC
A E
UFFI
CIQ
DP1/
PR. C
-4FG
16O
M16
1(
3G2,
5)
L3.Q
DP1/
PR..5
9CB
D.4
N.Q
DP1/
PR..5
10CB
D.4
TCB
D.4
FM U
FFIC
IO 1
QDP
1/PR
. C-5
FG16
OM
16
1(3G
2,5)
L1.Q
DP1/
PR..6
11CB
D.4
N.Q
DP1/
PR..6
12CB
D.4
TCB
D.4
FM U
FFIC
IO 2
QDP
1/PR
. C-6
FG16
OM
16
1(3G
2,5)
L2.Q
DP1/
PR..7
13CB
D.4
N.Q
DP1/
PR..7
14CB
D.4
TCB
D.4
FM S
UPPO
RTO
TEC
NICO
QDP
1/PR
. C-7
FG16
OM
16
1(3G
2,5)
L3.Q
DP1/
PR..8
15CB
D.N.
QDP
1/PR
..816
CBD.
TCB
D.
RIS
ERVA
Q
DP1/
PR. C
-8---
---
L1.Q
DP1/
PR..9
17CB
D.N.
QDP
1/PR
..918
CBD.
TCB
D.
RIS
ERVA
Q
DP1/
PR. C
-9---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: FORNITURA E POSA IN OPERA UPS ESCLUSA DAL'APPALTO
23/0
1/20
18
IEE-02-18
UPS-P1
UPS-P1
12 13mor007012UNIVERSITÁ SAPIENZA
ROMASchema morsettiera
UPS P1
1CB
D.6
2CB
D.6
3CB
D.6
4CB
D.6
TCB
D.6
Da Q
uadr
o Q
DP1/
NOR.
- Pa
rtenz
a Q
DP1/
NOR.
C-3
QDP
1/NO
R. C
-3FG
16O
M16
1(
5G4)
L1.U
PS-P
1.1
5CB
D.6
L2.U
PS-P
1.1
6CB
D.6
L3.U
PS-P
1.1
7CB
D.6
N.UP
S-P1
.18
CBD.
6T
CBD.
6
UP
S-P1
C-1
FG16
OM
16
1(5G
4)
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
13 14mor008013UNIVERSITÁ SAPIENZA
ROMASchema morsettiera
QUADRO CENTRALE TERMICA
L1.Q
CT.2
1CB
D.L2
.QCT
.22
CBD.
L3.Q
CT.2
3CB
D.N
.QCT
.24
CBD.
TCB
D.
Q
CT C
-2---
---
L1.Q
CT.3
5CB
D.50
L2.Q
CT.3
6CB
D.50
L3.Q
CT.3
7CB
D.50
N.Q
CT.3
8CB
D.50
TCB
D.50
GRU
PPO
FRI
GO
QCT
C-3
FG16
M16
/H07
Z1-K
_2 P
E 4
(1x3
5)+(
1PE3
5)
L1.Q
CT.4
9CB
D.35
L2.Q
CT.4
10CB
D.35
L3.Q
CT.4
11CB
D.35
N.Q
CT.4
12CB
D.35
TCB
D.35
UTA
1
QCT
C-4
FG16
M16
/H07
Z1-K
_2 P
E 3
(1x2
5)+(
1x16
)+(1
PE16
)
L1.Q
CT.6
13CB
D.4
L2.Q
CT.6
14CB
D.4
L3.Q
CT.6
15CB
D.4
TCB
D.4
EXT.
02
QCT
C-6
FG16
OM
16
1(4G
1,5)
L1.Q
CT.8
16CB
D.4
L2.Q
CT.8
17CB
D.4
L3.Q
CT.8
18CB
D.4
TCB
D.4
EXT.
02
QCT
C-8
FG16
OM
16
1(4G
1,5)
L1.Q
CT.1
019
CBD.
4L2
.QCT
.10
20CB
D.4
L3.Q
CT.1
021
CBD.
4T
CBD.
4
EXT.
02
QCT
C-1
0FG
16O
M16
1(
4G1,
5)
L1.Q
CT.1
222
CBD.
4L2
.QCT
.12
23CB
D.4
L3.Q
CT.1
224
CBD.
4T
CBD.
4
EXT.
03
QCT
C-1
2FG
16O
M16
1(
4G1,
5)
L1.Q
CT.1
425
CBD.
4L2
.QCT
.14
26CB
D.4
L3.Q
CT.1
427
CBD.
4T
CBD.
4
EXT.
04
QCT
C-1
4FG
16O
M16
1(
4G1,
5)
L1.Q
CT.1
628
CBD.
4L2
.QCT
.16
29CB
D.4
L3.Q
CT.1
630
CBD.
4T
CBD.
4
EXT.
05
QCT
C-1
6FG
16O
M16
1(
4G1,
5)
L1.Q
CT.1
831
CBD.
4L2
.QCT
.18
32CB
D.4
L3.Q
CT.1
833
CBD.
4T
CBD.
4
EXT.
06
QCT
C-1
8FG
16O
M16
1(
4G1,
5)
L1.Q
CT.2
034
CBD.
4L2
.QCT
.20
35CB
D.4
L3.Q
CT.2
036
CBD.
4T
CBD.
4
EXT.
07
QCT
C-2
0FG
16O
M16
1(
4G1,
5)
L1.Q
CT.2
237
CBD.
4L2
.QCT
.22
38CB
D.4
L3.Q
CT.2
239
CBD.
4T
CBD.
4
EXT.
08
QCT
C-2
2FG
16O
M16
1(
4G1,
5)
L1.Q
CT.2
440
CBD.
4L2
.QCT
.24
41CB
D.4
L3.Q
CT.2
442
CBD.
4T
CBD.
4
EP.0
1-A
QCT
C-2
4FG
16O
M16
1(
4G1,
5)
L1.Q
CT.2
643
CBD.
4L2
.QCT
.26
44CB
D.4
L3.Q
CT.2
645
CBD.
4T
CBD.
4
EP.0
1-B
QCT
C-2
6FG
16O
M16
1(
4G1,
5)
L1.Q
CT.2
846
CBD.
4L2
.QCT
.28
47CB
D.4
L3.Q
CT.2
848
CBD.
4T
CBD.
4
EP.0
2-A
QCT
C-2
8FG
16O
M16
1(
4G1,
5)
L1.Q
CT.3
049
CBD.
4L2
.QCT
.30
50CB
D.4
L3.Q
CT.3
051
CBD.
4T
CBD.
4
EP.0
2-B
QCT
C-3
0FG
16O
M16
1(
4G1,
5)
L1.Q
CT.3
252
CBD.
4L2
.QCT
.32
53CB
D.4
L3.Q
CT.3
254
CBD.
4T
CBD.
4
EP.0
3-A
QCT
C-3
2FG
16O
M16
1(
4G1,
5)
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
14 - mor008014UNIVERSITÁ SAPIENZA
ROMASchema morsettiera
QUADRO CENTRALE TERMICA
L1.Q
CT.3
455
CBD.
4L2
.QCT
.34
56CB
D.4
L3.Q
CT.3
457
CBD.
4T
CBD.
4
EP.0
3-B
QCT
C-3
4FG
16O
M16
1(
4G1,
5)
L1.Q
CT.3
658
CBD.
4L2
.QCT
.36
59CB
D.4
L3.Q
CT.3
660
CBD.
4T
CBD.
4
EP.0
4-A
QCT
C-3
6FG
16O
M16
1(
4G1,
5)
L1.Q
CT.3
861
CBD.
4L2
.QCT
.38
62CB
D.4
L3.Q
CT.3
863
CBD.
4T
CBD.
4
EP.0
4-B
QCT
C-3
8FG
16O
M16
1(
4G1,
5)
L1.Q
CT.4
064
CBD.
4L2
.QCT
.40
65CB
D.4
L3.Q
CT.4
066
CBD.
4T
CBD.
4
EP.0
5-A
QCT
C-4
0FG
16O
M16
1(
4G1,
5)
L1.Q
CT.4
267
CBD.
4L2
.QCT
.42
68CB
D.4
L3.Q
CT.4
269
CBD.
4T
CBD.
4
EP.0
5-B
QCT
C-4
2FG
16O
M16
1(
4G1,
5)
L3.Q
CT.4
370
CBD.
N.Q
CT.4
371
CBD.
TCB
D.
AUSI
LIAR
I Q
CT C
-43
---
---
L3.Q
CT.4
472
CBD.
N.Q
CT.4
473
CBD.
TCB
D.
RIS
ERVA
Q
CT C
-44
---
---
L1.Q
CT.4
574
CBD.
N.Q
CT.4
575
CBD.
TCB
D.
RIS
ERVA
Q
CT C
-45
---
---
MO
RS
ETT
ON
.TI
PO
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
1 2ver000001UNIVERSITÁ SAPIENZA
ROMA
CONDUTTURE - PROTEZIONIVERIFICA DEL COORDINAMENTO
Nelle tabelle riportate nei fogli seguenti sono riassunti i datiriguardanti le verifiche del coordinamento condutture -dispositivi di protezione, secondo quanto indicato di seguito:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(11)
(10)
(12)
DESCRIZIONEdella parte di impianto alimentata
DATI DELLA CONDUTTURA
formazioneLunghezza e lunghezza massima protettaCaduta di tensione % con la corrente di caricoIb e con la corrente nominale del dispositivo diprotezione a monte
DATI DELL'APPARECCHIATURA DIPROTEZIONE
MarcaModelloPolarita'
Corrente nominale su fase e neutroCorrente differenziale nominale (doveapplicabile)
PROTEZIONE CONTRO I CONTATTIINDIRETTI
Corrente di intervento del dispositivoCorrente di guasto a terra
PROTEZIONE CONTRO IL CORTOCIRCUITO
Potere di interruzione del dispositivo diprotezione (dove applicabile)Corrente di cortocircuito massima nel punto diinstallazione
Conduttore di fase
Conduttore di neutro
Conduttore di protezione (PE)
I t <= K S (Rif. CEI 64.8/4 Art. 434.3)2 2 2
Conduttore di fase
Conduttore di faseConduttore di neutro
Conduttore di neutro
PROTEZIONE CONTRO IL SOVRACCARICO
Ib <= In <= Iz (Rif. CEI 64.8 Art. 433.2)
If <= 1.45 Iz (Rif. CEI 64.8 Art. 433.2)
TEST RIASSUNTIVO
Protezione contro i cortocircuitiProtezione contro i sovraccarichiMassima caduta di tensione nell'impiantoMassima lunghezza delle linee di alimentazione
Esito positivo Esito negativo
Progetto INTEGRA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
2 3ver000002UNIVERSITÁ SAPIENZA
ROMA
5s
V
BCK
BCK
CONDUTTURE - PROTEZIONIVERIFICA DEL COORDINAMENTO
Valore relativo ad una condizionedi verifica con esito positivo
Valore relativo ad una condizionedi verifica con esito negativo
Valore non presente (datoincompleto)
Valore non significativo nellaconfigurazione scelta
235.2
235.2
- - -
Protezione contro i contattiindiretti realizzata con tempo diintervento di 5 secondi
Protezione contro i contattiindiretti realizzata mediantedoppio isolamento
Protezione contro i sovraccarichirealizzata dal dispositivo a valle
Richiesta la modalità diprotezione in backup per ildispositivo di protezione
Realizzata la modalità diprotezione in backup per ildispositivo di protezione
Progetto INTEGRA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18QGEN
3 4ver001003UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
Quadro Generale EDIFICIO
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QGEN C-0---
--- ---
0,65 0,89
SIEMENS
VL400.LI.TM
Quadripolare
55315 315
--- 12,26
3 780
6 006
---
---
---
---
---
---
306
315 315
--- ---
378
---
378
---
QGEN C-1
ALIMENTAZIONE ORDINARIA QUADRO PT
3(1x50)+(1x25)+(1PE25)
20 67
1,03 1,31
SIEMENS
3VA11 L/T TM220 ATFM 3RN/2
Quadripolare
25100 50
--- 12,16
1 500
3 259
1,91E+5
5,11E+7
1,6E+5
1,28E+7
1,6E+5
1,28E+7
93
100 50
123 82
130
178
65
119
QGEN C-2
ALIMENTAZIONE QP1
1(5G25)
15 112
0,9 1,28
SIEMENS
3VA10 L/T TM210 FTFM 3R
Quadripolare
1663 63
--- 12,16
756
3 220
1,29E+5
1,28E+7
9,88E+4
1,28E+7
9,92E+4
1,28E+7
42
63 63
74 74
82
107
82
107
QGEN C-3
ALIMENTAZIONE QCT
3(1x95)+(1x50)+(1PE50)
30 66
1,23 1,58
SIEMENS
3VA12 L/T TM240 ATAM 3RN/2
Quadripolare
36200 100
--- 12,16
2 400
3 608
1,91E+5
1,85E+8
1,6E+5
5,11E+7
1,6E+5
5,11E+7
171
200 100
269 175
260
390
130
254
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
4 5ver002004UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO PT
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDPT/NOR. C-0
GENERALE SEZ.NORMALE
---
--- ---
1,04 1,31
SIEMENS
3KA71164AA00
Quadripolare
---100 50
--- 9,27
1 500
3 255
---
---
---
---
---
---
93
100 50
--- ---
130
---
65
---
QDPT/NOR. C-1
SPD
---
--- ---
1,04 1,31
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
25100 50
--- 9,26
1 500
3 255
---
---
---
---
---
---
0
100 50
--- ---
130
---
65
---
QDPT/NOR. C-2
PRESENZA RETE
---
--- ---
1,04 1,74
SIEMENS
3NW6 Gr. 10x38 Ridotto
Tripolare
1002 2
--- 9,26
13
248
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QDPT/NOR. C-3
ALIMENTAZIONE QLT
1(5G10)
15 93
1,54 2,06
SIEMENS
5SL44507+5SM26468
Quadripolare
1050 50
0,3 9,26
0,3
1 436
1,11E+5
2,04E+6
4,52E+4
2,04E+6
4,75E+4
2,04E+6
36
50 50
54 54
65
78
65
78
QDPT/NOR. C-4
ALIMENTAZIONE QLAP
1(5G16)
15 177
1,31 1,92
SIEMENS
5SL44637+5SM26468
Quadripolare
1063 63
0,3 9,26
0,3
1 800
1,12E+5
5,23E+6
4,54E+4
5,23E+6
4,76E+4
5,23E+6
32
63 63
72 72
82
104
82
104
QDPT/NOR. C-5
ALIMENTAZIONE UPSPIANO TERRA
1(5G10)
15 86
1,59 2,14
SIEMENS
5SY64507+5SM26458
Quadripolare
1050 50
0,3 9,26
0,3
1 424
6,62E+4
2,04E+6
2,69E+4
2,04E+6
2,87E+4
2,04E+6
36
50 50
54 54
65
78
65
78
QDPT/NOR. C-6
AUSILIARI
---
--- ---
1,06 1,41
SIEMENS
5SU13537KK10
Monofase
1510 10
0,03 4,58
0,03
2 557
---
---
---
---
---
---
2,406
10 10
--- ---
13
---
13
---
QDPT/NOR. C-7
BATTERIEDI POST
1(3G1,5)
25 36
3,12 4,28
SIEMENS
5SU13537KK10
Monofase
1510 10
0,03 4,58
0,03
204
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
7,217
10 10
19 19
13
27
13
27
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
5 6ver002005UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO PT
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDPT/NOR. C-8
GENERALE ILLUMINAZIONECORRIDOIO
---
--- ---
1,12 1,41
SIEMENS
5SU13537KK10
Monofase
11,2510 10
0,03 4,58
0,03
2 557
---
---
---
---
---
---
7,698
10 10
--- ---
13
---
13
---
QDPT/NOR. C-9
ORDINARIADEPOSITO
1(3G1,5)
7 111
1,3 2,22
---
------10 10
--- 3,75
0,03
610
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
2,406
10 10
19 19
13
27
13
27
QDPT/NOR. C-10
ORDINARIA CORRIDOIOE FILTRO
1(3G1,5)
25 111
1,77 4,28
---
------10 10
--- 3,75
0,03
204
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
2,406
10 10
19 19
13
27
13
27
QDPT/NOR. C-11
ORDINARIADISIMPEGNO
1(3G1,5)
25 111
1,77 4,28
---
------10 10
--- 3,75
0,03
204
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
2,406
10 10
19 19
13
27
13
27
QDPT/NOR. C-12
EMERGENZA
1(3G1,5)
25 556
1,25 4,28
---
------10 10
--- 3,75
0,03
204
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
0,481
10 10
19 19
13
27
13
27
QDPT/NOR. C-13
GENERALE ILLUMINAZIONEAREA PROCESSI
---
--- ---
1,07 1,41
SIEMENS
5SU13537KK10
Monofase
11,2510 10
0,03 4,58
0,03
2 557
---
---
---
---
---
---
2,887
10 10
--- ---
13
---
13
---
QDPT/NOR. C-14
ORDINARIA
1(3G1,5)
15 113
1,46 3,14
---
------10 10
--- 3,75
0,03
324
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
2,406
10 10
19 19
13
27
13
27
QDPT/NOR. C-15
EMERGENZA
1(3G1,5)
15 566
1,14 3,14
---
------10 10
--- 3,75
0,03
324
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
0,481
10 10
19 19
13
27
13
27
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
6 7ver002006UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO PT
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDPT/NOR. C-16
GENERALE ILLUMINAZIONEDIDATTICA
---
--- ---
1,07 1,41
SIEMENS
5SU13537KK10
Monofase
11,2510 10
0,03 4,58
0,03
2 557
---
---
---
---
---
---
2,887
10 10
--- ---
13
---
13
---
QDPT/NOR. C-17
ORDINARIA
1(3G1,5)
20 113
1,59 3,71
---
------10 10
--- 3,75
0,03
250
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
2,406
10 10
19 19
13
27
13
27
QDPT/NOR. C-18
EMERGENZA
1(3G1,5)
20 566
1,17 3,71
---
------10 10
--- 3,75
0,03
250
9,05E+3
4,6E+4
8,87E+3
4,6E+4
9,05E+3
4,6E+4
0,481
10 10
19 19
13
27
13
27
QDPT/NOR. C-19
PRESE FRIGORIFERI
1(3G2,5)
10 44
1,77 2,65
SIEMENS
5SU13567KK16
Monofase
1516 16
0,03 4,58
0,03
701
1,11E+4
1,28E+5
1,1E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDPT/NOR. C-20
PRESE DISERVIZIO
1(3G2,5)
10 44
1,77 2,65
SIEMENS
5SU13567KK16
Monofase
1516 16
0,03 4,58
0,03
701
1,11E+4
1,28E+5
1,1E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDPT/NOR. C-21
PRESESCRIVANIA 1
1(3G2,5)
10 44
1,77 2,65
SIEMENS
5SU13567KK16
Monofase
1516 16
0,03 4,58
0,03
701
1,11E+4
1,28E+5
1,1E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDPT/NOR. C-22
PRESESCRIVANIA 2
1(3G2,5)
10 44
1,77 2,65
SIEMENS
5SU13567KK16
Monofase
1516 16
0,03 4,58
0,03
701
1,11E+4
1,28E+5
1,1E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDPT/NOR. C-23
PRESE SERVIZIOSUPP. PROCESSI
1(3G2,5)
10 44
1,77 2,65
SIEMENS
5SU13567KK16
Monofase
1516 16
0,03 4,58
0,03
701
1,11E+4
1,28E+5
1,1E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
18 18
21
25
21
25
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
7 8ver002007UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO PT
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDPT/NOR. C-24
RACKDATI
1(3G2,5)
10 45
1,74 2,54
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 4,58
0,03
701
1,19E+4
1,28E+5
1,16E+4
1,28E+5
1,19E+4
1,28E+5
9,623
16 16
26 26
21
38
21
38
QDPT/NOR. C-25
RISERVA
---
--- ---
1,04 1,42
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 4,58
0,03
2 768
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QDPT/NOR. C-26
RISERVA
---
--- ---
1,04 1,41
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 4,58
0,03
2 557
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDPT/PR.
QDPT/PR.
8 9ver002008UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO PT
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDPT/PR. C-0
GENERALE SEZ.PRIVILEGIATA
---
--- ---
1,91 3,06
SIEMENS
5TL14320
Quadripolare
---25 25
--- 1,81
0,3
4,86
---
---
---
---
---
---
9,623
25 25
--- ---
33
---
33
---
QDPT/PR. C-1
SPD
---
--- ---
1,91 3,06
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
2525 25
--- 1,8
0,3
4,86
---
---
---
---
---
---
0
25 25
--- ---
33
---
33
---
QDPT/PR. C-2
PRESENZA RETE
---
--- ---
1,91 3,49
SIEMENS
3NW6 Gr. 10x38 Ridotto
Tripolare
1002 2
--- 1,8
0,3
4,8
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QDPT/PR. C-3
PRESESCRIVANIA 1
1(3G2,5)
10 30
2,64 4,4
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 0,91
0,03
4,84
2,79E+3
1,28E+5
2,66E+3
1,28E+5
2,79E+3
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDPT/PR. C-4
PRESESCRIVANIA 2
1(3G2,5)
10 30
2,64 4,4
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 0,91
0,03
4,84
2,79E+3
1,28E+5
2,66E+3
1,28E+5
2,79E+3
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDPT/PR. C-5
RISERVA
---
--- ---
1,91 3,17
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 0,91
0,03
4,86
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QDPT/PR. C-6
RISERVA
---
--- ---
1,91 3,16
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 0,91
0,03
4,86
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
9 10ver003009UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO TECNICO
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLT/NOR. C-0
GENERALESEZ. NORMALE
---
--- ---
1,55 2,07
SIEMENS
5TL16631
Quadripolare
---50 50
--- 4,51
0,3
1 429
---
---
---
---
---
---
36
50 50
--- ---
65
---
65
---
QLT/NOR. C-1
SPD
---
--- ---
1,55 2,07
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
2550 50
--- 4,47
0,3
1 429
---
---
---
---
---
---
0
50 50
--- ---
65
---
65
---
QLT/NOR. C-2
PRESENZA RETE
---
--- ---
1,55 2,5
SIEMENS
3NW6 Gr. 10x38 Ridotto
Tripolare
1002 2
--- 4,47
0,3
225
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QLT/NOR. C-3---
--- ---
1,58 2,17
SIEMENS
5SU13537KK10
Monofase
11,2510 10
0,03 2,19
0,03
1 266
---
---
---
---
---
---
2,887
10 10
--- ---
13
---
13
---
QLT/NOR. C-4
ORDINARIA
1(3G1,5)
12 93
1,89 3,59
---
------10 10
--- 1,96
0,03
339
5,76E+3
4,6E+4
5,58E+3
4,6E+4
5,76E+3
4,6E+4
2,406
10 10
15 15
13
22
13
22
QLT/NOR. C-5
EMERGENZA
1(3G1,5)
8 467
1,62 3,12
---
------10 10
--- 1,96
0,03
448
5,76E+3
4,6E+4
5,58E+3
4,6E+4
5,76E+3
4,6E+4
0,481
10 10
15 15
13
22
13
22
QLT/NOR. C-6
FRIGOCOMBINATO
1(3G2,5)
10 49
2,08 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
7,217
16 16
18 18
21
25
21
25
QLT/NOR. C-7
ULTRACENTRIFUGA
1(3G2,5)
10 49
2,08 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
7,217
16 16
18 18
21
25
21
25
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
10 11ver003010UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO TECNICO
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLT/NOR. C-8
AUTOCLAVEPICCOLA
1(3G2,5)
10 49
2,08 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
7,217
16 16
18 18
21
25
21
25
QLT/NOR. C-9
INCUB.PIASTRE
1(3G2,5)
10 49
2,08 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
7,217
16 16
18 18
21
25
21
25
QLT/NOR. C-10
LIOFILIZZATORE
1(3G2,5)
10 49
2,08 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
7,217
16 16
18 18
21
25
21
25
QLT/NOR. C-11
SIST PURIFIC.H2O
1(3G2,5)
10 49
2,08 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
7,217
16 16
18 18
21
25
21
25
QLT/NOR. C-12
CABINA A FLUSSOLAMINARE
1(3G2,5)
10 49
2,08 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
7,217
16 16
18 18
21
25
21
25
QLT/NOR. C-13
AUTOCLAVEGRANDE
1(3G2,5)
10 49
2,08 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
7,217
16 16
18 18
21
25
21
25
QLT/NOR. C-14
BANCO 1
1(3G2,5)
10 22
2,7 3,37
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
14
16 16
20 20
21
28
21
28
QLT/NOR. C-15
BANCO 2
1(3G2,5)
10 22
2,7 3,37
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
14
16 16
20 20
21
28
21
28
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
11 12ver003011UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO TECNICO
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLT/NOR. C-16
BANCO 3
1(3G2,5)
10 22
2,7 3,37
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
14
16 16
20 20
21
28
21
28
QLT/NOR. C-17
LAVAVETRERIA
1(5G6)
15 103
1,94 2,73
SIEMENS
5SL44257+5SM23436
Quadripolare
1025 25
0,03 4,47
0,03
711
2,26E+4
7,36E+5
9,08E+3
7,36E+5
9,95E+3
7,36E+5
16
25 25
27 27
33
39
33
39
QLT/NOR. C-18
PRESE DISERVIZIO
1(3G2,5)
10 >99999
1,55 3,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
545
7,22E+3
1,28E+5
6,96E+3
1,28E+5
7,22E+3
1,28E+5
0
16 16
18 18
21
25
21
25
QLT/NOR. C-19
RISERVA
---
--- ---
1,55 2,18
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,19
0,03
1 319
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QLT/NOR. C-20
RISERVA
---
--- ---
1,55 2,17
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 2,19
0,03
1 266
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
QLT/NOR. C-21
RISERVA
---
--- ---
1,55 2,17
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 2,19
0,03
1 266
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/PR
QLT/PR
12 13ver003012UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO LABORATORIO TECNICO
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLT/PR C-0
GENERALESEZ. PRIVILEGIATA
---
--- ---
2,08 3,06
SIEMENS
5TL14320
Quadripolare
---25 25
--- 1,81
0,3
4,86
---
---
---
---
---
---
14
25 25
--- ---
33
---
33
---
QLT/PR C-1
SPD
---
--- ---
2,08 3,06
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
2525 25
--- 1,8
0,3
4,86
---
---
---
---
---
---
0
25 25
--- ---
33
---
33
---
QLT/PR C-2
PRESENZA RETE
---
--- ---
2,08 3,49
SIEMENS
3NW6 Gr. 10x38 Ridotto
Tripolare
1002 2
--- 1,8
0,3
4,8
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QLT/PR C-3
BANCO 1
1(3G2,5)
10 18
3,21 4,34
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 0,91
0,03
4,84
2,79E+3
1,28E+5
2,66E+3
1,28E+5
2,79E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLT/PR C-4
BANCO 2
1(3G2,5)
10 18
3,21 4,34
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 0,91
0,03
4,84
2,79E+3
1,28E+5
2,66E+3
1,28E+5
2,79E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLT/PR C-5
BANCO 3
1(3G2,5)
10 18
3,21 4,34
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 0,91
0,03
4,84
2,79E+3
1,28E+5
2,66E+3
1,28E+5
2,79E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLT/PR C-6
RISERVA
---
--- ---
2,08 3,17
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 0,91
0,03
4,86
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QLT/PR C-7
RISERVA
---
--- ---
2,08 3,16
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 0,91
0,03
4,86
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
13 14ver004013UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLAP/NOR. C-0
GENERALESEZ. NORMALE
---
--- ---
1,32 1,93
SIEMENS
5TL16631
Quadripolare
---63 50
--- 5,55
0,3
1 789
---
---
---
---
---
---
32
63 50
--- ---
82
---
65
---
QLAP/NOR. C-1
SPD
---
--- ---
1,32 1,93
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
2563 50
--- 5,49
0,3
1 789
---
---
---
---
---
---
0
63 50
--- ---
82
---
65
---
QLAP/NOR. C-2
PRESENZA RETE
---
--- ---
1,32 2,36
SIEMENS
3NW6 Gr. 10x38 Ridotto
Tripolare
1002 2
--- 5,49
0,3
232
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QLAP/NOR. C-3---
--- ---
1,35 2,03
SIEMENS
5SU13537KK10
Monofase
11,2510 10
0,03 2,71
0,03
1 544
---
---
---
---
---
---
2,887
10 10
--- ---
13
---
13
---
QLAP/NOR. C-4
ORDINARIA
1(3G1,5)
12 102
1,66 3,45
---
------10 10
--- 2,36
0,03
356
6,65E+3
4,6E+4
6,41E+3
4,6E+4
6,65E+3
4,6E+4
2,406
10 10
15 15
13
22
13
22
QLAP/NOR. C-5
EMERGENZA
1(3G1,5)
12 511
1,41 3,45
---
------10 10
--- 2,36
0,03
356
6,65E+3
4,6E+4
6,41E+3
4,6E+4
6,65E+3
4,6E+4
0,481
10 10
15 15
13
22
13
22
QLAP/NOR. C-6
BANCO 1
1(3G2,5)
10 25
2,45 3,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
591
8,5E+3
1,28E+5
8,15E+3
1,28E+5
8,5E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLAP/NOR. C-7
BANCO 2
1(3G2,5)
10 25
2,45 3,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
591
8,5E+3
1,28E+5
8,15E+3
1,28E+5
8,5E+3
1,28E+5
14
16 16
21 21
21
30
21
30
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
14 15ver004014UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLAP/NOR. C-8
BANCO 3
1(3G2,5)
10 25
2,45 3,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
591
8,5E+3
1,28E+5
8,15E+3
1,28E+5
8,5E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLAP/NOR. C-9
BANCO 4
1(3G2,5)
10 25
2,45 3,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
591
8,5E+3
1,28E+5
8,15E+3
1,28E+5
8,5E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLAP/NOR. C-10
BANCO 5
1(3G2,5)
10 25
2,45 3,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
591
8,5E+3
1,28E+5
8,15E+3
1,28E+5
8,5E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLAP/NOR. C-11
PRESE DISERVIZIO
1(3G2,5)
10 24
2,5 3,27
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
591
8,5E+3
1,28E+5
8,15E+3
1,28E+5
8,5E+3
1,28E+5
14
16 16
18 18
21
25
21
25
QLAP/NOR. C-12
AUSILIARI
---
--- ---
1,32 2,04
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
1 622
---
---
---
---
---
---
0,962
16 16
--- ---
21
---
21
---
QLAP/NOR. C-13
RISERVA
---
--- ---
1,32 2,04
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
1 622
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QLAP/NOR. C-14
RISERVA
---
--- ---
1,32 2,04
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 2,71
0,03
1 622
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QLAP/NOR. C-15
RISERVA
---
--- ---
1,32 2,03
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 2,71
0,03
1 544
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
15 16ver004015UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLAP/NOR. C-16
RISERVA
---
--- ---
1,32 2,03
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 2,71
0,03
1 544
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/PR.
QLAP.PR
16 17ver004016UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO LABORATORIO AREA PROCESSI
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLAP.PR C-0
GENERALE SEZ. PRIVILEGIATA
---
--- ---
2,29 2,93
SIEMENS
5TL14400
Quadripolare
---32 32
--- 2,26
0,3
4,87
---
---
---
---
---
---
29
32 32
--- ---
42
---
42
---
QLAP.PR C-1
SPD
---
--- ---
2,29 2,93
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
2532 32
--- 2,25
0,3
4,87
---
---
---
---
---
---
0
32 32
--- ---
42
---
42
---
QLAP.PR C-2
PRESENZA RETE
---
--- ---
2,29 3,36
SIEMENS
3NW6 Gr. 10x38 Ridotto
Tripolare
1002 2
--- 2,25
0,3
4,81
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QLAP.PR C-3
BANCO 1
1(3G2,5)
10 16
3,42 4,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 1,13
0,03
4,85
3,66E+3
1,28E+5
3,48E+3
1,28E+5
3,66E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLAP.PR C-4
BANCO 2
1(3G2,5)
10 16
3,42 4,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 1,13
0,03
4,85
3,66E+3
1,28E+5
3,48E+3
1,28E+5
3,66E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLAP.PR C-5
BANCO 3
1(3G2,5)
10 16
3,42 4,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 1,13
0,03
4,85
3,66E+3
1,28E+5
3,48E+3
1,28E+5
3,66E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLAP.PR C-6
BANCO 4
1(3G2,5)
10 16
3,42 4,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 1,13
0,03
4,85
3,66E+3
1,28E+5
3,48E+3
1,28E+5
3,66E+3
1,28E+5
14
16 16
21 21
21
30
21
30
QLAP.PR C-7
BANCO 5
1(3G2,5)
10 16
3,42 4,21
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 1,13
0,03
4,85
3,66E+3
1,28E+5
3,48E+3
1,28E+5
3,66E+3
1,28E+5
14
16 16
21 21
21
30
21
30
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/PR.
QLAP.PR
17 18ver004017UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO LABORATORIO AREA PROCESSI
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QLAP.PR C-8
RISERVA
---
--- ---
2,29 3,04
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 1,13
0,03
4,87
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QLAP.PR C-9
RISERVA
---
--- ---
2,29 3,03
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 1,13
0,03
4,87
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: UPS ESCLUSO DALLA FORNITURA E POSA IN OPERA
23/0
1/20
18
IEE-02-18
UPS-PT
UPS-PT
18 19ver005018UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
UPS-PT
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
UPS-PT C-0---
--- ---
1,59 2,14
---
------50 50
--- 4,44
0,3
4,88
---
---
---
---
---
---
37
50 50
--- ---
65
---
65
---
UPS-PT C-1
ALIM. SEZ. PRIVILEGIATAQLT
1(5G4)
15 78
2,07 3,05
SIEMENS
5SL44257
Quadripolare
1025 25
--- 4,44
0,3
4,86
2,33E+4
3,27E+5
9,39E+3
3,27E+5
1,01E+4
3,27E+5
14
25 25
30 30
33
44
33
44
UPS-PT C-2
ALIMENTAZ. SEZ. PRIV.QLAP
1(5G6)
15 54
2,28 2,92
SIEMENS
5SL44327
Quadripolare
1032 32
--- 4,44
0,3
4,87
3,07E+4
7,36E+5
1,25E+4
7,36E+5
1,33E+4
7,36E+5
29
32 32
39 39
42
56
42
56
UPS-PT C-3
ALIMENTAZIONE SEZ. PRIV.QDPT
1(5G4)
15 121
1,9 3,05
SIEMENS
5SL44257
Quadripolare
1025 25
--- 4,44
0,3
4,86
2,33E+4
3,27E+5
9,39E+3
3,27E+5
1,01E+4
3,27E+5
9,623
25 25
30 30
33
44
33
44
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
19 20ver006019UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO P1
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDP1/NOR. C-0
GENERALE SEZ.NORMALE
---
--- ---
0,91 1,3
SIEMENS
5TL16631
Quadripolare
---63 63
--- 8,26
756
3 185
---
---
---
---
---
---
42
63 63
--- ---
82
---
82
---
QDP1/NOR. C-1
SPD
---
--- ---
0,91 1,3
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
2563 63
--- 8,13
756
3 185
---
---
---
---
---
---
0
63 63
--- ---
82
---
82
---
QDP1/NOR. C-2
PRESENZA RETE
---
--- ---
0,91 1,73
SIEMENS
3NW6 Gr. 10x38 Ridotto
Tripolare
1002 2
--- 8,13
13
247
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QDP1/NOR. C-3
ALIMENTAZIONE UPS PIANO 1
1(5G4)
15 64
1,66 2,51
SIEMENS
5SY64327+5SM26458
Quadripolare
1532 32
0,3 8,13
0,3
752
4,09E+4
3,27E+5
1,95E+4
3,27E+5
2,13E+4
3,27E+5
22
32 32
34 34
42
49
42
49
QDP1/NOR. C-4
GENERALE ILLUMINAZIONECORRIDOIO
---
--- ---
0,95 1,4
SIEMENS
5SU13537KK10
Monofase
11,2510 10
0,03 4,54
0,03
2 508
---
---
---
---
---
---
3,849
10 10
--- ---
13
---
13
---
QDP1/NOR. C-5
ORDINARIA CORRIDOIO
1(3G1,5)
20 117
1,47 3,7
---
------10 10
--- 3,71
0,03
250
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
2,406
10 10
19 19
13
27
13
27
QDP1/NOR. C-6
ORDINARIA DISIMPEGNO
1(3G1,5)
20 294
1,16 3,7
---
------10 10
--- 3,71
0,03
250
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
0,962
10 10
19 19
13
27
13
27
QDP1/NOR. C-7
EMERGENZA
1(3G1,5)
20 588
1,05 3,7
---
------10 10
--- 3,71
0,03
250
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
0,481
10 10
19 19
13
27
13
27
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
20 21ver006020UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO P1
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDP1/NOR. C-8
GENERALE ILLUMINAZIONEUFFICI E INFORMATICA
---
--- ---
0,95 1,4
SIEMENS
5SU13537KK10
Monofase
11,2510 10
0,03 4,54
0,03
2 508
---
---
---
---
---
---
3,849
10 10
--- ---
13
---
13
---
QDP1/NOR. C-9
ORDINARIA UFFICIO 1
1(3G1,5)
20 117
1,47 3,7
---
------10 10
--- 3,71
0,03
250
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
2,406
10 10
19 19
13
27
13
27
QDP1/NOR. C-10
ORDINARIA UFF.2 E INFORMATICA
1(3G1,5)
20 294
1,16 3,7
---
------10 10
--- 3,71
0,03
250
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
0,962
10 10
19 19
13
27
13
27
QDP1/NOR. C-11
EMERGENZA
1(3G1,5)
20 588
1,05 3,7
---
------10 10
--- 3,71
0,03
250
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
0,481
10 10
19 19
13
27
13
27
QDP1/NOR. C-12
GENERALE ILLUMINAZIONERIUNIONI E SUPP. TEC.
---
--- ---
0,95 1,4
SIEMENS
5SU13537KK10
Monofase
11,2510 10
0,03 4,54
0,03
2 508
---
---
---
---
---
---
3,849
10 10
--- ---
13
---
13
---
QDP1/NOR. C-13
ORDINARIA RIUNIONI
1(3G1,5)
20 117
1,47 3,7
---
------10 10
--- 3,71
0,03
250
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
2,406
10 10
19 19
13
27
13
27
QDP1/NOR. C-14
ORDINARIA SUPPORTO TECNICO
1(3G1,5)
20 294
1,16 3,7
---
------10 10
--- 3,71
0,03
250
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
0,962
10 10
19 19
13
27
13
27
QDP1/NOR. C-15
EMERGENZA
1(3G1,5)
25 588
1,08 4,27
---
------10 10
--- 3,71
0,03
204
8,99E+3
4,6E+4
8,78E+3
4,6E+4
8,99E+3
4,6E+4
0,481
10 10
19 19
13
27
13
27
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
21 22ver006021UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO P1
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDP1/NOR. C-16
FM FAN COILRECUPERATORE
1(3G2,5)
10 64
1,43 2,53
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 4,54
0,03
696
1,11E+4
1,28E+5
1,09E+4
1,28E+5
1,11E+4
1,28E+5
7,217
16 16
26 26
21
38
21
38
QDP1/NOR. C-17
RACKDATI
1(3G2,5)
5 47
1,3 1,97
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 4,54
0,03
1 114
1,11E+4
1,28E+5
1,09E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
26 26
21
38
21
38
QDP1/NOR. C-18
PRESEDI SERVIZIO
1(3G2,5)
15 45
1,97 3,26
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 4,54
0,03
505
1,11E+4
1,28E+5
1,09E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDP1/NOR. C-19
FM INFORMATICAE UFFICI
1(3G2,5)
5 45
1,31 2,02
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 4,54
0,03
1 114
1,11E+4
1,28E+5
1,09E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDP1/NOR. C-20
FM RIUNIONI E SUPP. TECNICO
1(3G2,5)
5 45
1,31 2,02
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 4,54
0,03
1 114
1,11E+4
1,28E+5
1,09E+4
1,28E+5
1,11E+4
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDP1/NOR. C-21
RISERVA
---
--- ---
0,91 1,41
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 4,54
0,03
2 713
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QDP1/NOR. C-22
RISERVA
---
--- ---
0,91 1,4
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 4,54
0,03
2 508
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/PR.
QDP1/PR.
22 23ver006022UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO P1
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDP1/PR. C-0
GENERALE SEZ.PRIVILEGIATA
---
--- ---
2,33 3,43
SIEMENS
5TL14320
Quadripolare
---25 25
--- 1,29
0,3
4,86
---
---
---
---
---
---
19
25 25
--- ---
33
---
33
---
QDP1/PR. C-1
SPD
---
--- ---
2,33 3,43
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
2525 25
--- 1,29
0,3
4,86
---
---
---
---
---
---
0
25 25
--- ---
33
---
33
---
QDP1/PR. C-2
PRESENZA RETE
---
--- ---
2,33 3,86
SIEMENS
3NW6 Gr. 10x38 Ridotto
Tripolare
1002 2
--- 1,29
0,3
4,8
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QDP1/PR. C-3
FM INFORMATICAE UFFICI
1(3G2,5)
5 24
2,72 4,15
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 0,67
0,03
4,85
1,89E+3
1,28E+5
1,82E+3
1,28E+5
1,89E+3
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDP1/PR. C-4
FM INFORMATICAE UFFICI
1(3G2,5)
5 24
2,72 4,15
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 0,67
0,03
4,85
1,89E+3
1,28E+5
1,82E+3
1,28E+5
1,89E+3
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDP1/PR. C-5
FM UFFICIO1
1(3G2,5)
5 24
2,72 4,15
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 0,67
0,03
4,85
1,89E+3
1,28E+5
1,82E+3
1,28E+5
1,89E+3
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDP1/PR. C-6
FM UFFICIO2
1(3G2,5)
5 24
2,72 4,15
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 0,67
0,03
4,85
1,89E+3
1,28E+5
1,82E+3
1,28E+5
1,89E+3
1,28E+5
9,623
16 16
18 18
21
25
21
25
QDP1/PR. C-7
FM SUPPORTO TECNICO
1(3G2,5)
5 24
2,72 4,15
SIEMENS
5SU13537KK16
Monofase
1516 16
0,03 0,67
0,03
4,85
1,89E+3
1,28E+5
1,82E+3
1,28E+5
1,89E+3
1,28E+5
9,623
16 16
18 18
21
25
21
25
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/PR.
QDP1/PR.
23 24ver006023UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO P1
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QDP1/PR. C-8
RISERVA
---
--- ---
2,33 3,54
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 0,67
0,03
4,86
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QDP1/PR. C-9
RISERVA
---
--- ---
2,33 3,53
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 0,67
0,03
4,86
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: FORNITURA E POSA IN OPERA UPS ESCLUSA DAL'APPALTO
23/0
1/20
18
IEE-02-18
UPS-P1
UPS-P1
24 25ver007024UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
UPS P1
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
UPS-P1 C-0---
--- ---
1,66 2,51
---
------32 32
--- 2,28
0,3
4,88
---
---
---
---
---
---
19
32 32
--- ---
42
---
42
---
UPS-P1 C-11(5G4)
15 55
2,32 3,42
SIEMENS
5SL44257
Quadripolare
1025 25
--- 2,28
0,3
4,86
1,06E+4
3,27E+5
4,58E+3
3,27E+5
4,81E+3
3,27E+5
19
25 25
30 30
33
44
33
44
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
25 26ver008025UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
QUADRO CENTRALE TERMICA
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QCT C-0
GENERALEQCT
---
--- ---
1,23 1,58
SIEMENS
3KA71224AA00
Quadripolare
---200 100
--- 9,41
2 400
3 602
---
---
---
---
---
---
171
200 100
--- ---
260
---
130
---
QCT C-1
SPD
---
--- ---
1,23 1,58
SIEMENS
Classe II - Up 1.4 kV normale + Seg. Fisso
Quadripolare
25200 100
--- 9,39
2 400
3 602
---
---
---
---
---
---
0
200 100
--- ---
260
---
130
---
QCT C-2---
--- ---
1,23 2,01
SIEMENS
3NW6 Gr. 10x38 SEGN.
Quadripolare
1002 2
--- 9,39
13
250
---
---
---
---
---
---
0
2 2
--- ---
4,2
---
4,2
---
QCT C-3
GRUPPOFRIGO
4(1x35)+(1PE35)
40 53
2,27 3,01
SIEMENS
3VA11 L/T TM210 FTFM 3R
Quadripolare
25125 125
--- 9,39
1 500
1 750
1,75E+5
2,51E+7
1,27E+5
2,51E+7
1,28E+5
2,51E+7
96
125 125
144 144
163
209
163
209
QCT C-4
UTA 1
3(1x25)+(1x16)+(1PE16)
40 42
2,16 2,89
SIEMENS
3VA11 L/T TM220 ATFM 3RN/2
Quadripolare
2580 40
--- 9,39
1 200
1 246
1,75E+5
1,28E+7
1,27E+5
5,23E+6
1,27E+5
5,23E+6
61
80 40
82 62
104
119
52
89
QCT C-5---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
QCT C-6
EXT.02
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-7---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
26 27ver008026UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
QUADRO CENTRALE TERMICA
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QCT C-8
EXT.02
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-9---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
QCT C-10
EXT.02
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-11---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
QCT C-12
EXT.03
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-13---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
QCT C-14
EXT.04
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-15---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
27 28ver008027UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
QUADRO CENTRALE TERMICA
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QCT C-16
EXT.05
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-17---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
QCT C-18
EXT.06
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-19---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
QCT C-20
EXT.07
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-21---
--- ---
2,02 2,61
SIEMENS
3RV20110GA15
Tripolare
1000,63 0,63
--- 9,39
6,6
35
---
---
---
---
---
---
0,481
0,63 0,63
--- ---
0,756
---
0,756
---
QCT C-22
EXT.08
1(4G1,5)
15 676
2,06 2,67
SIEMENS
3RT20151AB01
Tripolare
---0,63 ---
--- 0,05
6,6
32
5,31
4,6E+4
---
---
5,3
4,6E+4
0,481
0,63 ---
7,41 ---
0,756
11
---
---
QCT C-23---
--- ---
1,42 1,83
SIEMENS
3RV20111DA10
Tripolare
1003,2 3,2
--- 9,39
43
634
---
---
---
---
---
---
2,486
3,2 3,2
--- ---
3,84
---
3,84
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
28 29ver008028UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
QUADRO CENTRALE TERMICA
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QCT C-24
EP.01-A
1(4G1,5)
15 119
1,64 2,11
SIEMENS
3RT20151AB01
Tripolare
---3,2 ---
--- 1,09
43
230
5,63E+2
4,6E+4
---
---
5,28E+2
4,6E+4
2,486
3,2 ---
7,41 ---
3,84
11
---
---
QCT C-25---
--- ---
1,42 1,77
SIEMENS
3RV20111DA10
Tripolare
1002,5 2,5
--- 9,39
43
634
---
---
---
---
---
---
2,486
2,5 2,5
--- ---
3
---
3
---
QCT C-26
EP.01-B
1(4G1,5)
15 119
1,64 1,99
SIEMENS
3RT20151AB01
Tripolare
---2,5 ---
--- 1,09
43
230
5,63E+2
4,6E+4
---
---
5,28E+2
4,6E+4
2,486
2,5 ---
7,41 ---
3
11
---
---
QCT C-27---
--- ---
1,4 1,75
SIEMENS
3RV20111DA10
Tripolare
1002,2 2,2
--- 9,39
43
634
---
---
---
---
---
---
2,197
2,2 2,2
--- ---
2,64
---
2,64
---
QCT C-28
EP.02-A
1(4G1,5)
15 119
1,59 1,94
SIEMENS
3RT20151AB01
Tripolare
---2,2 ---
--- 1,09
43
230
5,63E+2
4,6E+4
---
---
5,28E+2
4,6E+4
2,197
2,2 ---
7,41 ---
2,64
11
---
---
QCT C-29---
--- ---
1,4 1,83
SIEMENS
3RV20111DA10
Tripolare
1003,2 3,2
--- 9,39
43
634
---
---
---
---
---
---
2,197
3,2 3,2
--- ---
3,84
---
3,84
---
QCT C-30
EP.02-B
1(4G1,5)
15 119
1,59 2,11
SIEMENS
3RT20151AB01
Tripolare
---3,2 ---
--- 1,09
43
230
5,63E+2
4,6E+4
---
---
5,28E+2
4,6E+4
2,197
3,2 ---
7,41 ---
3,84
11
---
---
QCT C-31---
--- ---
1,61 2,1
SIEMENS
3RV20110KA15
Tripolare
1001,25 1,25
--- 9,39
16
133
---
---
---
---
---
---
0,898
1,25 1,25
--- ---
1,5
---
1,5
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
29 30ver008029UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
QUADRO CENTRALE TERMICA
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QCT C-32
EP.03-A
1(4G1,5)
15 303
1,68 2,21
SIEMENS
3RT20151AB01
Tripolare
---1,25 ---
--- 0,21
16
97
3,27E+1
4,6E+4
---
---
3,23E+1
4,6E+4
0,898
1,25 ---
7,41 ---
1,5
11
---
---
QCT C-33---
--- ---
1,61 2,1
SIEMENS
3RV20110KA15
Tripolare
1001,25 1,25
--- 9,39
16
133
---
---
---
---
---
---
0,898
1,25 1,25
--- ---
1,5
---
1,5
---
QCT C-34
EP.03-B
1(4G1,5)
15 303
1,68 2,21
SIEMENS
3RT20151AB01
Tripolare
---1,25 ---
--- 0,21
16
97
3,27E+1
4,6E+4
---
---
3,23E+1
4,6E+4
0,898
1,25 ---
7,41 ---
1,5
11
---
---
QCT C-35---
--- ---
1,43 2,1
SIEMENS
3RV20110KA15
Tripolare
1001,25 1,25
--- 9,39
16
133
---
---
---
---
---
---
0,481
1,25 1,25
--- ---
1,5
---
1,5
---
QCT C-36
EP.04-A
1(4G1,5)
15 303
1,48 2,21
SIEMENS
3RT20151AB01
Tripolare
---1,25 ---
--- 0,21
16
97
3,27E+1
4,6E+4
---
---
3,23E+1
4,6E+4
0,481
1,25 ---
7,41 ---
1,5
11
---
---
QCT C-37---
--- ---
1,43 2,1
SIEMENS
3RV20110KA15
Tripolare
1001,25 1,25
--- 9,39
16
133
---
---
---
---
---
---
0,481
1,25 1,25
--- ---
1,5
---
1,5
---
QCT C-38
EP.04-B
1(4G1,5)
15 303
1,48 2,21
SIEMENS
3RT20151AB01
Tripolare
---1,25 ---
--- 0,21
16
97
3,27E+1
4,6E+4
---
---
3,23E+1
4,6E+4
0,481
1,25 ---
7,41 ---
1,5
11
---
---
QCT C-39---
--- ---
1,4 1,78
SIEMENS
3RV20111EA10
Tripolare
1004 4
--- 9,39
52
909
---
---
---
---
---
---
3,304
4 4
--- ---
4,8
---
4,8
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
30 - ver008030UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
QUADRO CENTRALE TERMICA
TN-S 3F+N 400 10
VERIFICA DEL COORDINAMENTOCONDUTTURE - PROTEZIONI
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
(12)
Descrizione
Conduttura
FormazioneLung. / Lung. max prot.[m]
C.di.T. % con Ib / In
Apparecchiatura
MarcaModelloPolarità
In F/NIdn
[A]
Contatti indiretti / Corto Circuito
IintIgt
[A]
P.d.I.Ik Max
[kA]
FaseI t
K S[A s]
2
2 22
NeutroI t
K S[A s]
2
22
2
PEI t
K S[A s]
2
2
2
2
Sovraccarico
IbIn F/NIz F/N
[A]
If F/N1,45 Iz F/N
[A]
Test
QCT C-40
EP.05-A
1(4G1,5)
15 100
1,69 2,14
SIEMENS
3RT20151AB01
Tripolare
---4 ---
--- 1,64
52
258
1,23E+3
4,6E+4
---
---
1,15E+3
4,6E+4
3,304
4 ---
7,41 ---
4,8
11
---
---
QCT C-41---
--- ---
1,4 1,78
SIEMENS
3RV20111EA10
Tripolare
1004 4
--- 9,39
52
909
---
---
---
---
---
---
3,304
4 4
--- ---
4,8
---
4,8
---
QCT C-42
EP.05-B
1(4G1,5)
15 100
1,69 2,14
SIEMENS
3RT20151AB01
Tripolare
---4 ---
--- 1,64
52
258
1,23E+3
4,6E+4
---
---
1,15E+3
4,6E+4
3,304
4 ---
7,41 ---
4,8
11
---
---
QCT C-43
AUSILIARI
---
--- ---
1,24 1,69
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 4,9
0,03
3 033
---
---
---
---
---
---
0,481
16 16
--- ---
21
---
21
---
QCT C-44
RISERVA
---
--- ---
1,23 1,69
SIEMENS
5SU13547KK16
Monofase
1016 16
0,03 4,9
0,03
3 033
---
---
---
---
---
---
0
16 16
--- ---
21
---
21
---
QCT C-45
RISERVA
---
--- ---
1,23 1,69
SIEMENS
5SU13547KK10
Monofase
1010 10
0,03 4,9
0,03
2 788
---
---
---
---
---
---
0
10 10
--- ---
13
---
13
---
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
1 2car001001UNIVERSITÁ SAPIENZA
ROMA
ELENCO DEI CARICHI
Nelle pagine seguenti è riportato l'elenco dei carichi elettricipresenti nell'impianto
Progetto INTEGRA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
2 3car002002UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO PT
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QDPT/NOR. C-6AUSILIARI Utenza generica
Monofase L1+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDPT/NOR. C-7BATTERIEDI POST
Utenza genericaMonofase L3+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QDPT/NOR. C-9ORDINARIADEPOSITO
Utenza genericaMonofase L1+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDPT/NOR. C-10ORDINARIA CORRIDOIOE FILTRO
Utenza genericaMonofase L1+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDPT/NOR. C-11ORDINARIADISIMPEGNO
Utenza genericaMonofase L1+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDPT/NOR. C-12EMERGENZA Utenza generica
Monofase L1+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
QDPT/NOR. C-14ORDINARIA Utenza generica
Monofase L1+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDPT/NOR. C-15EMERGENZA Utenza generica
Monofase L1+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
QDPT/NOR. C-17ORDINARIA Utenza generica
Monofase L2+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDPT/NOR. C-18EMERGENZA Utenza generica
Monofase L2+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
QDPT/NOR. C-19PRESE FRIGORIFERI
Utenza genericaMonofase L3+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDPT/NOR. C-20PRESE DISERVIZIO
Utenza genericaMonofase L1+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA: CORRENTE DI C.C. STIMATA DA VERIFICARE DURANTE ESECUZIONE
23/0
1/20
18
IEE-02-18
QDPT/NOR.
QDPT/NOR.
3 4car002003UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO PT
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QDPT/NOR. C-21PRESESCRIVANIA 1
Utenza genericaMonofase L2+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDPT/NOR. C-22PRESESCRIVANIA 2
Utenza genericaMonofase L3+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDPT/NOR. C-23PRESE SERVIZIOSUPP. PROCESSI
Utenza genericaMonofase L1+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDPT/NOR. C-24RACKDATI
Utenza genericaMonofase L2+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDPT/PR.
QDPT/PR.
4 5car002004UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO PT
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QDPT/PR. C-3PRESESCRIVANIA 1
Utenza genericaMonofase L1+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDPT/PR. C-4PRESESCRIVANIA 2
Utenza genericaMonofase L2+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
5 6car003005UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO TECNICO
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QLT/NOR. C-4ORDINARIA Utenza generica
Monofase L1+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QLT/NOR. C-5EMERGENZA Utenza generica
Monofase L1+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
QLT/NOR. C-6FRIGOCOMBINATO
Utenza genericaMonofase L2+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QLT/NOR. C-7ULTRACENTRIFUGA Utenza generica
Monofase L3+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QLT/NOR. C-8AUTOCLAVEPICCOLA
Utenza genericaMonofase L1+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QLT/NOR. C-9INCUB.PIASTRE
Utenza genericaMonofase L2+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QLT/NOR. C-10LIOFILIZZATORE Utenza generica
Monofase L3+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QLT/NOR. C-11SIST PURIFIC.H2O
Utenza genericaMonofase L1+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QLT/NOR. C-12CABINA A FLUSSOLAMINARE
Utenza genericaMonofase L2+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QLT/NOR. C-13AUTOCLAVEGRANDE
Utenza genericaMonofase L3+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QLT/NOR. C-14BANCO 1 Utenza generica
Monofase L1+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLT/NOR. C-15BANCO 2 Utenza generica
Monofase L2+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/NOR.
QLT/NOR.
6 7car003006UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO TECNICO
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QLT/NOR. C-16BANCO 3 Utenza generica
Monofase L3+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLT/NOR. C-17LAVAVETRERIA Utenza generica
Quadripolare
400 V11 10 0,9 16 100
0 20 40 60 80 100
QLT/NOR. C-18PRESE DISERVIZIO
Utenza genericaMonofase L3+N
230 V0 0 --- 0 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLT/PR
QLT/PR
7 8car003007UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO LABORATORIO TECNICO
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QLT/PR C-3BANCO 1 Utenza generica
Monofase L1+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLT/PR C-4BANCO 2 Utenza generica
Monofase L2+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLT/PR C-5BANCO 3 Utenza generica
Monofase L3+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/NOR.
QLAP/NOR.
8 9car004008UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO LABORATORIO AREA PROCESSI
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QLAP/NOR. C-4ORDINARIA Utenza generica
Monofase L1+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QLAP/NOR. C-5EMERGENZA Utenza generica
Monofase L1+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
QLAP/NOR. C-6BANCO 1 Utenza generica
Monofase L2+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP/NOR. C-7BANCO 2 Utenza generica
Monofase L3+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP/NOR. C-8BANCO 3 Utenza generica
Monofase L1+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP/NOR. C-9BANCO 4 Utenza generica
Monofase L2+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP/NOR. C-10BANCO 5 Utenza generica
Monofase L3+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP/NOR. C-11PRESE DISERVIZIO
Utenza genericaMonofase L1+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP/NOR. C-12AUSILIARI Utenza generica
Monofase L2+N
230 V0,222 0,2 0,9 0,962 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QLAP/PR.
QLAP.PR
9 10car004009UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO LABORATORIO AREA PROCESSI
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QLAP.PR C-3BANCO 1 Utenza generica
Monofase L1+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP.PR C-4BANCO 2 Utenza generica
Monofase L2+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP.PR C-5BANCO 3 Utenza generica
Monofase L3+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP.PR C-6BANCO 4 Utenza generica
Monofase L1+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
QLAP.PR C-7BANCO 5 Utenza generica
Monofase L2+N
230 V3,333 3 0,9 14 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
10 11car006010UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO P1
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QDP1/NOR. C-5ORDINARIA CORRIDOIO
Utenza genericaMonofase L3+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDP1/NOR. C-6ORDINARIA DISIMPEGNO
Utenza genericaMonofase L3+N
230 V0,222 0,2 0,9 0,962 100
0 20 40 60 80 100
QDP1/NOR. C-7EMERGENZA Utenza generica
Monofase L3+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
QDP1/NOR. C-9ORDINARIA UFFICIO 1
Utenza genericaMonofase L1+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDP1/NOR. C-10ORDINARIA UFF.2 E INFORMATICA
Utenza genericaMonofase L1+N
230 V0,222 0,2 0,9 0,962 100
0 20 40 60 80 100
QDP1/NOR. C-11EMERGENZA Utenza generica
Monofase L1+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
QDP1/NOR. C-13ORDINARIA RIUNIONI
Utenza genericaMonofase L3+N
230 V0,556 0,5 0,9 2,406 100
0 20 40 60 80 100
QDP1/NOR. C-14ORDINARIA SUPPORTO TECNICO
Utenza genericaMonofase L3+N
230 V0,222 0,2 0,9 0,962 100
0 20 40 60 80 100
QDP1/NOR. C-15EMERGENZA Utenza generica
Monofase L3+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
QDP1/NOR. C-16FM FAN COILRECUPERATORE
Utenza genericaMonofase L1+N
230 V1,667 1,5 0,9 7,217 100
0 20 40 60 80 100
QDP1/NOR. C-17RACKDATI
Utenza genericaMonofase L2+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDP1/NOR. C-18PRESEDI SERVIZIO
Utenza genericaMonofase L3+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/NOR.
QDP1/NOR.
11 12car006011UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE NORMALEQUADRO P1
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QDP1/NOR. C-19FM INFORMATICAE UFFICI
Utenza genericaMonofase L1+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDP1/NOR. C-20FM RIUNIONI E SUPP. TECNICO
Utenza genericaMonofase L2+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
QDP1/PR.
QDP1/PR.
12 13car006012UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
SEZIONE PRIVILEGIATAQUADRO P1
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QDP1/PR. C-3FM INFORMATICAE UFFICI
Utenza genericaMonofase L1+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDP1/PR. C-4FM INFORMATICAE UFFICI
Utenza genericaMonofase L2+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDP1/PR. C-5FM UFFICIO1
Utenza genericaMonofase L3+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDP1/PR. C-6FM UFFICIO2
Utenza genericaMonofase L1+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
QDP1/PR. C-7FM SUPPORTO TECNICO
Utenza genericaMonofase L2+N
230 V2,222 2 0,9 9,623 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
13 14car008013UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
QUADRO CENTRALE TERMICA
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QCT C-3GRUPPOFRIGO
Utenza genericaQuadripolare
400 V67 60 0,9 96 100
0 20 40 60 80 100
QCT C-4UTA 1 Utenza generica
Quadripolare
400 V42 38 0,9 61 100
0 20 40 60 80 100
QCT C-6EXT.02 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-8EXT.02 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-10EXT.02 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-12EXT.03 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-14EXT.04 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-16EXT.05 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-18EXT.06 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-20EXT.07 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-22EXT.08 Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-24EP.01-A Utenza generica
Tripolare
400 V1,722 1,55 0,9 2,486 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18QCT
14 - car008014UNIVERSITÁ SAPIENZA
ROMA
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRASistema
QUADRO CENTRALE TERMICA
TN-S 3F+N 400 10
Descrizione
ELENCO DEI CARICHI INSTALLATI
Tipo PolaritàTensione
Potenza
[kVA] [kW] cosphi
Ib[A]
Ku[%]
QCT C-26EP.01-B Utenza generica
Tripolare
400 V1,722 1,55 0,9 2,486 100
0 20 40 60 80 100
QCT C-28EP.02-A Utenza generica
Tripolare
400 V1,522 1,37 0,9 2,197 100
0 20 40 60 80 100
QCT C-30EP.02-B Utenza generica
Tripolare
400 V1,522 1,37 0,9 2,197 100
0 20 40 60 80 100
QCT C-32EP.03-A Utenza generica
Tripolare
400 V0,622 0,56 0,9 0,898 100
0 20 40 60 80 100
QCT C-34EP.03-B Utenza generica
Tripolare
400 V0,622 0,56 0,9 0,898 100
0 20 40 60 80 100
QCT C-36EP.04-A Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-38EP.04-B Utenza generica
Tripolare
400 V0,333 0,3 0,9 0,481 100
0 20 40 60 80 100
QCT C-40EP.05-A Utenza generica
Tripolare
400 V2,289 2,06 0,9 3,304 100
0 20 40 60 80 100
QCT C-42EP.05-B Utenza generica
Tripolare
400 V2,289 2,06 0,9 3,304 100
0 20 40 60 80 100
QCT C-43AUSILIARI Utenza generica
Monofase L3+N
230 V0,111 0,1 0,9 0,481 100
0 20 40 60 80 100
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
1 2pos008001UNIVERSITÁ SAPIENZA
ROMA
TIPOLOGIE DI POSA DEI CAVI
Nelle pagine seguenti è riportato l'elenco dei cavi,con le tipologie di posa utilizzate
Progetto INTEGRA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
2 - pos000002UNIVERSITÁ SAPIENZA
ROMATipi di pose utilizzate
DATI DELLA FORNITURA
Fasi Tensione [V]R [ ]terra ohm
Progetto INTEGRA
TIPOLOGIE DI POSA UTILIZZATE
Posa Norma riferimentoCodifica Posa CEI 64-8
Norma riferimentoCodifica Posa CEI 64-8
Posa
EPR32_
CEI 35024/1
Unipolare
Cavi senza guaina e cavimultipolari (o unipolari conguaina), posati su parete
con percorso verticale
EPR31_
CEI 35024/1
Unipolare
Cavi senza guaina e cavimultipolari (o unipolari conguaina), posati su paretecon percorso orizzontale
EPR13_
CEI 35024/1
Multipolare
Cavi multipolari (o unipolaricon guaina) .... e cavi conisolamento minerale: su
passerelle perforateEPR__2
CEI 35024/1
Multipolare
Cavi multipolari in tubiprotettivi circolari posatientro muri termicamente
isolanti
EPR_3A
CEI 35024/1
MultipolareCavi multipolari in tubi
protettivi circolari posati su odistanziati da pareti
EPR34A
CEI 35024/1
Multipolare
Cavi multipolari (o unipolaricon guaina) posati in canali
sospesi
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
1 2leg008001UNIVERSITÁ SAPIENZA
ROMA
Nelle pagine seguenti è riportata la legenda dei simboli graficiutilizzati per la stesura degli elaborati.
LEGENDA SIMBOLI GRAFICI
Progetto INTEGRA
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
2 3leg008002UNIVERSITÁ SAPIENZA
ROMA
V
Voltmetro
A
Amperometro contrasformatoreamperometrico
Hz Mult
Multimetro
M
Comando motorizzato Attuatore che siaziona ruotando
Id
Blocco differenziale Bloccoelettromagnetico Blocco termico
Bobina o dispositivodi comando
I >
Dispositivo dicomando di un relèa massima corrente
Dispositivo dicomando di un relèa minima corrente
Dispositivo dicomando di un relèa massima tensione
I <U > U <
Dispositivo dicomando di un relèa minima tensione
Trasformatore adue avvolgimenti
Meccanismo asgancio libero
Trasformatoredi isolamento
IdQ
Interruttoredifferenziale conrelè incorporato
Q
Interruttoreautomatico con relèmagnetico
Id
Q
Interruttore automaticomagnetico Differenziale
Q
Interruttore automaticomagnetoTermico conrelè o sganciatori
Id
Q
Interruttore automaticomagnetoTermicoDifferenziale
Q
Id
Q
Interruttore automaticocon sganciatoreTermicoDifferenziale
Cosfimetro
Presenza tensione
Id
Bobina di comandodi un relè adaggancio meccanico
Bobina di comando diun relè a rimanenza
Bobina di comando diun relè ad orologio
QS
Interruttore dimanovra-sezionatore
F
Interruttore dimanovra-sezionatore-fusibile
Trasformatoreamperometrico
Relè differenzialecon toroide
Trasformatoredi sicurezza
LegendaF - Fusibili
K - ContattoriNA - Contattinormalmente apertiNC - Contattinormalmente chiusiQ - InterruttoriQS - SezionatoriSC - Scambio
Q
Id
Interruttoreautomaticomagnetico estraibile
Interruttore automaticomagnetoTermicoDifferenziale estraibile
Interruttore automaticomagnetoTermicoestraibile
Relè passo-passo
K
Q
Frequenzimetrocon trasformatoreamperometrico
Interruttoreautomatico con relètermico
Trasformatoretriangolo-stella, secondariocon neutro accessibile
Terra di protezioneP - Presa
Trasformatore atre avvolgimenti
Dispositivo di protezioneper le sovratensioni SPD
Id - Relè differenzialiGE - Gruppo elettrogeno
ba
QS
QSQS
Q
51N
Q5051
Interruttore automatico Interruttore automatico50\51\51N x MT
Sezionatore Sezionatore di terra Sezionatore rotativo
Kt K K K
Bobina di comando diun relè temporizzato
Interruttore magnetoTermico con termicaregolabile-Salvamotore
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
23/0
1/20
18
IEE-02-18
3 - leg008003UNIVERSITÁ SAPIENZA
ROMA
Contatti ausiliari1NA e 1NC
2X 2X 2X 2X2X 2X 3X 3X
4X 4X4X 4X 8X8X
K
Contattore concontatti 1NA
K
Contattore concontatti 1NA e 1NC
K
Contattore concontatti 1NC
2X
K
Contattore concontatti 2NA
2X2X
K
Contattore concontatti 2NA e 2NC
2X
K
Contattore concontatti 2NC
3X
K
Contattore concontatti 3NA
4X
K
Contattore concontatti 4NA
K
Contattore concontatti 4NC
K
Contattore Contattoausiliario NA
4X
Legenda
3X
Contatti ausiliari1NA e 2NC
Contatti ausiliari2NA
Contatti ausiliari2NA e 1NC
Contatti ausiliari2NA e 2NC
Contatti ausiliari2NC
Contatti ausiliari2SC
Contatti ausiliari3NA
Contatti ausiliari3NA e 1NC
Contatti ausiliari3NC
Contatti ausiliari4NA
Contatti ausiliari4NA e 4NC
Contatti ausiliari4NC
Contatti ausiliari8NA
Contatti ausiliari8NA e 8NC
Contattoausiliario NC
Contattoausiliario SC
Contatto ausiliario1SC e 1NA
Contatto ausiliario1SC, 1NA e 1NC
8X
NA - Contattinormalmente aperti
SC - Scambio
GE - Gruppo elettrogeno
QS - SezionatoriQ - Interruttori
NC - Contattinormalmente chiusi
P - Presa
K - ContattoriId - Relè differenziali
FU - Fusibile
Commutatore
kWh
RETE GE QS
Conduttura trifase conconduttore di neutroMorsettoContatore dell'ente
distributore Punto di connessione
CondensatoreInterblocco meccanicotra rete e GE
GE
FU
Componente oapparecchio di classe IIGruppo elettrogeno Morsetto
Fusibile
Simbolo di estraibile
PP
Presa con contattodi protezione
Presa interbloccatatripolare
Lampada o lampadadi segnalazione
Partenza fornitura
ChiaveInterruttoreorario
Interruttorecrepuscolare
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
UNIVERSITÁ SAPIENZA
ROMA
FRONTE QUADRO
Nelle pagine seguenti sono riportati i disegni dei FrontiQuadro
Progetto INTEGRA
fro000001
24/0
1/20
18
IEE-02-18
1 2
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
UNIVERSITÁ SAPIENZA
ROMA
QUADRO PTSEZIONE NORMALE
fro001002
24/0
1/20
18
IEE-02-18QDPT/NOR.
2 3
8 g f 2 560
8 g f 4 465
F 1C.01
8 G F 7 146
8 G F 7 146
8 g f 2 561
8 g f 4 465
8 G F 4 400
F 1C.02
QDPT/NOR. C-0 - 3KA711
1
0
8 G F 7 0 981
Pannello 1
8 G F 7 0 981
Pannello 2
8 G F 7 0 981
Pannello 3
8 G F 7 0 981
Pannello 4
MORSETTIERA
CORRENTE DI PICCO (kA):
FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:
PROFONDITA' (mm):LARGHEZZA (mm):
COLORE INVOLUCRO:
CORRENTE NOMINALE AMMISSIBILE x 1s (kA):
TIPO DI PORTA:
ALTEZZA (mm):
NORMA DI RIFERIMENTO:TIPO DI QUADRO:
DATI IDENTIFICATIVI DEL QUADRO
CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):
ACCESSIBILITA':
RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo
SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali
ALPHA 630CEI EN 61439-2
400/23002553
1.7501.020250
IP43 (senza porta IP3X)Forma 1
RAL 7035VEDI DISEGNOANTERIORE
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO TECNICOSEZIONE NORMALE
fro002003
24/0
1/20
18
IEE-02-18QLT/NOR.
3 4
8 g f 1 741
8 g f 4 462
F 1C.01
8 G F 7 0 981
Pannello 1
8 G F 7 0 981
Pannello 2
8 G F 7 0 981
Pannello 3
8 G F 7 0 981
Pannello 4
8 G F 7 0 981
Pannello 5
MORSETTIERA
CORRENTE DI PICCO (kA):
FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:
PROFONDITA' (mm):LARGHEZZA (mm):
COLORE INVOLUCRO:
CORRENTE NOMINALE AMMISSIBILE x 1s (kA):
TIPO DI PORTA:
ALTEZZA (mm):
NORMA DI RIFERIMENTO:TIPO DI QUADRO:
DATI IDENTIFICATIVI DEL QUADRO
CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):
ACCESSIBILITA':
RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo
SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali
ALPHA 630CEI EN 61439-2
400/23002553
1.250660250
IP43 (senza porta IP3X)Forma 1
RAL 7035VEDI DISEGNOANTERIORE
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
UNIVERSITÁ SAPIENZA
ROMA
QUADRO LABORATORIO AREA PROCESSISEZIONE NORMALE
fro003004
24/0
1/20
18
IEE-02-18QLAP/NOR.
4 5
8 G F 7 0 982
8 G F 7 0 983
F 1C.01
Pannello 1
CORRENTE DI PICCO (kA):
FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:
PROFONDITA' (mm):LARGHEZZA (mm):
COLORE INVOLUCRO:
CORRENTE NOMINALE AMMISSIBILE x 1s (kA):
TIPO DI PORTA:
ALTEZZA (mm):
NORMA DI RIFERIMENTO:TIPO DI QUADRO:
DATI IDENTIFICATIVI DEL QUADRO
CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):
ACCESSIBILITA':
RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo
SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali
ALPHA 125CEI 23-48 23-49
400/23001017
1.050660140
IP43 (senza porta IP3X)Forma 1
RAL 7035VEDI DISEGNOANTERIORE
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
UNIVERSITÁ SAPIENZA
ROMA
UPS-PT fro004005
24/0
1/20
18
IEE-02-18UPS-PT
5 6
C.01
CORRENTE DI PICCO (kA):
FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:
PROFONDITA' (mm):LARGHEZZA (mm):
COLORE INVOLUCRO:
CORRENTE NOMINALE AMMISSIBILE x 1s (kA):
TIPO DI PORTA:
ALTEZZA (mm):
NORMA DI RIFERIMENTO:TIPO DI QUADRO:
DATI IDENTIFICATIVI DEL QUADRO
CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):
ACCESSIBILITA':
RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo
SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali
CENTRALINOCEI 23-48 23-49 23-51
400/23001017
310465101
IP40VEDI DISEGNO
--VEDI DISEGNOANTERIORE
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
UNIVERSITÁ SAPIENZA
ROMA
QUADRO P1SEZIONE NORMALE
fro005006
24/0
1/20
18
IEE-02-18QDP1/NOR.
6 7
8 G F 7 0 982
8 G F 7 0 983
F 1C.01
Pannello 1
CORRENTE DI PICCO (kA):
FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:
PROFONDITA' (mm):LARGHEZZA (mm):
COLORE INVOLUCRO:
CORRENTE NOMINALE AMMISSIBILE x 1s (kA):
TIPO DI PORTA:
ALTEZZA (mm):
NORMA DI RIFERIMENTO:TIPO DI QUADRO:
DATI IDENTIFICATIVI DEL QUADRO
CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):
ACCESSIBILITA':
RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo
SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali
ALPHA 125CEI 23-48 23-49
400/23001017
1.050660140
IP43 (senza porta IP3X)Forma 1
RAL 7035VEDI DISEGNOANTERIORE
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
UNIVERSITÁ SAPIENZA
ROMA
UPS P1 fro006007
24/0
1/20
18
IEE-02-18UPS-P1
7 8
C.01CORRENTE DI PICCO (kA):
FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:
PROFONDITA' (mm):LARGHEZZA (mm):
COLORE INVOLUCRO:
CORRENTE NOMINALE AMMISSIBILE x 1s (kA):
TIPO DI PORTA:
ALTEZZA (mm):
NORMA DI RIFERIMENTO:TIPO DI QUADRO:
DATI IDENTIFICATIVI DEL QUADRO
CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):
ACCESSIBILITA':
RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo
SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali
CENTRALINOCEI 23-48 23-49 23-51
400/23001017
19324097
IP40VEDI DISEGNO
--VEDI DISEGNOANTERIORE
TITOLO COMMITTENTE SEGUE
CONTR.
DISEGNO
ELAB.
FILE FOGLIO
APPR.
F
E
D
C
B
A
1 32 4 5 6 7 8
F
E
D
C
B
A
1 32 4 5 6 7 8
CODICE
COMMESSA
PREFISSO
DAT
A:
NOTA:
UNIVERSITÁ SAPIENZA
ROMA
QUADRO CENTRALE TERMICA fro007008
24/0
1/20
18
IEE-02-18QCT
8 -
8 g f 2 580
8 g f 4 466
F 1C.01
8 G F 7 147
8 G F 7 147
8 g f 2 583
8 g f 4 466
8 G F 4 401
F 1C.02
QCT C-0 - 3KL712
1
0
8 G F 7 0 984
Pannello 1
8 G F 7 0 984
Pannello 2
3VA1 3VA1
8 G F 7 0 984
Pannello 3
8 G F 7 0 984
Pannello 4
MORSETTIERA
8 G F 9 674
CORRENTE DI PICCO (kA):
FORMA COSTRUTTIVA:GRADO DI PROTEZIONE:
PROFONDITA' (mm):LARGHEZZA (mm):
COLORE INVOLUCRO:
CORRENTE NOMINALE AMMISSIBILE x 1s (kA):
TIPO DI PORTA:
ALTEZZA (mm):
NORMA DI RIFERIMENTO:TIPO DI QUADRO:
DATI IDENTIFICATIVI DEL QUADRO
CORRENTE NOMINALE SBARRE (A):TENSIONE NOMINALE (V):
ACCESSIBILITA':
RIFERIMENTI PORTATA SBARRE:SB OS: Sbarre orizzontali superioriSB OM: Sbarre orizzontali nel mezzo
SB VP: Sbarre verticali posterioriSB VL: Sbarre verticali laterali
ALPHA 630CEI EN 61439-2
400/23002553
2.1501.353251
IP55 (senza porta IP3X)Forma 1
RAL 7035VEDI DISEGNOANTERIORE