Guida ai sensoricontent2.smcetech.com/pdf/D_IT.pdf · 2016. 3. 16. · Sensori allo stato solido...

82
6-15 Guida ai sensori Sensori Reed Sensori allo stato solido Sensori reed P 6-21 Sensori allo stato solido P 6-43 Esecuzione generica ······························································· P 6-44 A fascetta, Con guida, Con tirante, Montaggio diretto Con LED bicolore ·································································· P 6-60 A fascetta, Con guida, Montaggio diretto Con LED bicolore e uscita di diagnostica ····························· P 6-67 A fascetta, Con guida, Montaggio diretto Resistente all’acqua, con LED bicolore ································· P 6-73 A fascetta, Con guida, Con tirante, Montaggio diretto Con timer ··················································································· P 6-77 A fascetta, Con guida, Con tirante, Montaggio diretto Resistente a campi magnetici intensi, con LED bicolore ····· P . 6-82 Con guida Sensore allo stato solido con connettore precablato ··········· P . 6-86 Esecuzione generica ·······························································P 6-22 A fascetta, Con guida, Con tirante, Montaggio diretto Con LED bicolore ································································· P 6-40 A fascetta, Con guida, Con tirante

Transcript of Guida ai sensoricontent2.smcetech.com/pdf/D_IT.pdf · 2016. 3. 16. · Sensori allo stato solido...

  • 6-15

    Guida ai sensoriSensori ReedSensori allo stato solido

    Sensori reedP 6-21

    Sensori allo stato solido P 6-43

    � Esecuzione generica ······························································· P 6-44 A fascetta, Con guida, Con tirante, Montaggio diretto

    � Con LED bicolore ·································································· P 6-60 A fascetta, Con guida, Montaggio diretto

    � Con LED bicolore e uscita di diagnostica ····························· P 6-67 A fascetta, Con guida, Montaggio diretto

    � Resistente all’acqua, con LED bicolore ································· P 6-73 A fascetta, Con guida, Con tirante, Montaggio diretto

    � Con timer ··················································································· P 6-77 A fascetta, Con guida, Con tirante, Montaggio diretto

    � Resistente a campi magnetici intensi, con LED bicolore ····· P. 6-82 Con guida

    � Sensore allo stato solido con connettore precablato ··········· P. 6-86

    � Esecuzione generica ·······························································P 6-22 A fascetta, Con guida, Con tirante, Montaggio diretto

    � Con LED bicolore ································································· P 6-40 A fascetta, Con guida, Con tirante

  • 6-16

    6-58

    6-57

    6-55

    6-37

    6-38

    Funzione Tipo di sens. Connessione elettrica Modello sensori

    Pag. Tipo di

    montaggio

    Sen

    sori

    gen

    eric

    i

    Sen

    sori

    ree

    d

    Fascetta

    Guida

    Tirante

    Montaggio diretto

    Grommet

    Connettore

    Box di collegamento

    Terminale DIN

    Grommet

    Connettore

    Grommet

    Box di collegamento

    Terminale DIN

    Grommet

    D–C73/C76/C80

    D–B53/B54/B64

    D–C73C/C80C

    D–A33/A34

    D–A33A/A34A

    D–A44

    D–A44A

    D–A72/A73/A80

    D–A72H/A73H/A76H/A80H

    D–A73/A80 C

    D–A53/A54/A56/A64/A67

    D–A33C/A34C

    D–A44C

    D–A90/A93/A96

    D–A90V/A93V/A96V

    D–90/97

    D–90A/93A

    D–Z73/Z76/Z80

    D-R73/R80

    D-R73C/80C

    D–E73A/E76A/E80A

    Sen

    sori

    sta

    to s

    olid

    o

    D–H7A1/H7A2/H7B

    D–G59/G5P/K59

    D–H7C

    D–G39/K39

    D–G39A/K39A

    D–F79/F7P/J79

    D–F7NV/F7PV/F7BV

    D–J79C

    D–F59/F5P/J59/J51

    D–G39C/K39C

    D–M9N/FM9P/M9B

    D–M9NV/M9PV/M9BV

    D-F8N/F8P/F8B

    D–Y59A/Y7P/Y59B

    D–Y69A/Y7PV/Y69B

    D–S99(V)/S9P(V)/T99(V)

    D–S79/S7P/T79(C)

    D–M5N/M5P/M5B

    Fascetta

    Guida

    Tirante

    Montaggio diretto

    Grommet

    Connettore

    Box di collegamento

    Grommet

    Connettore

    Grommet

    Box di collegamento

    Grommet

    6-22

    6-23

    6-24

    6-25

    6-26

    6-25

    6-26

    6-27

    6-28

    6-29

    6-30

    6-31

    6-32

    6-33

    6-34

    6-35

    6-36

    6-39

    6-44

    6-45

    6-46

    6-47

    6-48

    6-49

    6-50

    6-51

    6-52

    6-53

    6-54

    6-56

    6-59

    Gamma dei sensori SMC

    Sensori generici

    Montaggio a fascetta Montaggio su guida

    Montaggio con tirante Montaggio diretto

  • 6-17

    Gamma dei sensori SMCL

    ED

    bic

    olo

    re

    Funzione Tipo di sens. Connessione elettrica Modello sensori Pag. Tipo di

    montaggio

    L'operazione adatta può essere indicata con luce verde. (Rosso → Verde ← Rosso) S

    enso

    riR

    eed

    Sen

    sori

    stat

    o so

    lido

    Fascetta Guida Tirante

    Fascetta

    Guida

    Tirante

    Montaggio diretto

    Grommet Grommet Grommet

    Grommet

    Grommet

    Grommet

    Grommet

    D–B59W

    D–A79W

    D–A59W

    D–H7NW/H7PW/H7BW

    D–G59W/G5PW/K59W

    D–F79W/F7PW/J79W D–F7NWV/F7BWV

    D–F59W/F5PW/J59W

    D–M5NW/M5PW/M5BW D–Y7NW/Y7PW/Y7BW D–Y7NWV/Y7PWV/Y7BWV D–M9NW/M9PW/M9BW D–M9NWV/M9PWV/M9BWV

    LED

    bico

    lore

    con

    uscit

    a diag

    nost

    ica

    Il segnale d'uscita può essere captato in un area di rilevamento variabile.

    Sens

    ori s

    tato

    sol

    ido

    Fascetta

    Guida

    Tirante

    Grommet

    Grommet

    Grommet

    D–H7LF (Esecuzione mantenuta)

    D–H7NF

    D–G59F

    D–F7LF (Esecuzione mantenuta)

    D–F79F

    D–F5LF (Esecuzione mantenuta)

    D–F59F

    Resit

    ente

    all'ac

    qua

    LED

    bicolo

    re

    Resistente all'acqua e ai refrigeranti

    Sen

    sori

    allo

    stat

    o so

    lido

    Fascetta

    Guida

    Tirante

    Montaggio diretto

    Grommet

    Grommet

    Grommet

    Grommet

    D–H7BAL

    D–G5BAL

    D–F7BAL

    D–F5BAL

    D–Y7BAL

    D–M9BAL

    Co

    n t

    imer

    Con timer OFF incorporato (200ms)

    Sen

    sori

    allo

    stat

    o s

    olid

    o

    Fascetta

    Guida

    Tirante

    Montaggio diretto

    Grommet

    Grommet

    Grommet

    Grommet

    D–G5NTL

    D–F7NTL

    D–F5NTL

    D–M5NTL/M5PTL

    Resis

    tenz

    a ai

    cam

    pi m

    agne

    tici

    Possibile utilizzo in ambienti esposti a campi magnetici.

    Sens

    ori a

    llost

    ato

    solid

    o 10

    0

    Guida Grommet D–P5DWL

    6-40

    6-41

    6-42

    6-60

    6-61

    6-62

    6-63

    6-64

    6-65

    6-66

    6-84

    6-67

    6-68

    6-69

    6-70

    6-71

    6-83

    6-72

    6-73

    6-74

    6-75

    6-76

    6-81

    6-85

    6-77

    6-78

    6-79

    6-80

    6-82

    Con

    conn

    etto

    re

    prec

    abla

    to

    Sensore allo stato solido con connettore precablato

    Sen

    sori

    allo

    stat

    o so

    lido

    Con connettore D–���PC 6-86Fascetta

    Guida

    Montaggio diretto

    LED bicolore

    Con timerLED bicolore con uscita di diagnostica

    Resistente all’acqua con LED bicolore

  • 6-18

    Caratteristiche Comuni dei Sensori

    Tipo di sensore

    Dispersione di corrente

    Tempo di risposta

    Resistenza agli urti

    Resistenza d'isolamento

    Tensione di isolamento

    Temperatura d'esercizio

    Costruzione protettiva

    Sensori reed

    Nessuno

    1.2ms

    300m/s 2

    1500Vca/min. (Tra cavo e corpo) (1)

    Sensori stato solido

    3 fili≤100μ A, 2 fili: ≥1mA)

    ≥ 1ms (3)

    1000m/s 2

    1000Vca/min. (Tra cavo e corpo)

    ≥ 50 M � 500Vcc (tra cavo e corpo)

    –10 ÷ 60˚C

    IEC529 Standard IP67, Costruzione resistente all'acqua (JISC0920)(2)

    Nota 1) Esecuzione connettore(D–A73C/A80C/C73C/C80C) e D–9/9 � A/A9/A9 � Esecuzione V: 1000Vca/min. (Tra cavo e corpo) Nota 2) IEC529 Standard IP63, Costruzione impermeabile (JISC0920) per esecuzione box di collegamento (D–A3/A3 � A/A3 � C/G39/G39A/G39C/K39/K39A/K39C)

    e terminale DIN tipo (D–A44/A44A/A44C). Nota 3) Eccetto sensori allo stato solido con timer(D–M5 � TL, G5NTL, F7NTL, F5NTL) and Sensore resistente a forti campi magnetici(D–P5DWL).

    D–J51: ≤5ms

    Lunghezza cavi

    Codici d’ordinazione Es.)

    D–A73 � Lunghezza cavi

    L Z

    N∗

    0.5m 3m 5m

    Nessuno ∗ Solo per connettore (D– ∗∗ C)

    L

    Nota 1) Sensori applicabili con 5 m di cavo (“Z”) Sensori reed: D-B53/B54, D-C73 (C)/C80C,D-A73(C)(H)/A80C D-A53/A54, D-Z73, D-90/97/90A/93A Sensori allo stato solido: Realizzati su richiesta (Tranne D-M9/M9�V) Nota 2) La lunghezza standard del cavo dei sensori allo stato solido con timer

    o con LED bicolore resistente all’acqua misura 3 metri. Nota 3) Il cavo del sensore allo stato solido con schermo magnetico resistnte a

    forti campi magnetici misura 3 o 5 metri. (Non disponibile 0.5m.)

    Codice

    D–LC05

    D–LC30

    D–LC50

    Lunghezza cavi

    0.5m

    3m

    5m

    Codice lunghezza cavi con connettore (applicabile solo per connettore)

    Cambio di colore del cavo

    Il colore dei cavi dei sensori SMC è cambiato in ottemperanza alle norme dello standard n. 402 dell’Associazione delle industrie d’impianti di controllo elettrico del Giappone.

    Uscita

    Uscita

    Rosso

    Vecchio

    Nero

    Marrone

    Nuovo

    Blu

    Impianti da 2 fili Impianti da 3 fili

    Alimentazione

    GND

    Rosso

    Vecchio

    Nero

    Marrone

    Nuovo

    Blu

    Uscita Bianco Nero

    Alimentazione

    GND

    Rosso

    Vecchio

    Nero

    Marrone

    Nuovo

    Blu

    Sensori stato solido con uscita di diagnostica

    Sensori stato solido con uscita diagnostica mantenuta

    Uscita Bianco Nero

    Uscita diagnostica

    Giallo Arancione

    Alimentazione

    GND

    Rosso

    Vecchio

    Nero

    Marrone

    Nuovo

    Blu

    Uscita (Bianco) Nero

    Uscita didiagnosticamantenuta Giallo Arancione

    Avvertenze

    Istruzioni d’usoCaratteristiche dei sensori

  • 6-19

    Box di protezione contatti/CD-P11, CD-P12

    Soppressore di picchi

    Bobina d'arresto

    OUT Marrone (Rosso)

    OUT Blu (Nero)

    Diodo Zener

    Bobina d'arresto OUT (+) Marrone (Rosso)

    OUT (–) Bl (N )

    Istruzioni d’usoIsteresi dei sensori/Box di protezione contatti

    Isteresi dei sensori

    La distanza tra i punto d’attivazione (ON) e il punto di disattivazione (OFF) percorsa dal pistone è detta “Isteresi”. Questa isteresi è compresa nel campo d’esercizio (un lato).

    Nota) L’isteresi può subire fluttuazioni a causa dell’ambiente circos-tante. In caso di problemi relativi all’isteresi, contattare SMC.

    1I seguenti sensori non sono incorporati al box di protezione contatti.D-A7/A8, D-A7�H/A80H, D-A73C, A80C, D-C7/C8, D-C73C/C80C, D-E7�A, E80A, D-Z7/Z8, D-9/9�A, D-A9/A9�V, and D-A79W typeUsare sensore con box di protezione contatti nei casi elen-cati qui sotto. Se non si usa tale box, la durata dei sensori si accorcerebbe.(A causa della permanente condizione energizzata.)D-A72(H) deve essere usata con il box protezione contatti con qualsiasi tipo di carico e lunghezza cavo.qIl carico d’esercizio è induttivo.wIl cavo del carico è ≥ 5m.eLa tensione di carico 100 o 200 Vca. 2Per usare il circuito di protezione contatti incorporato con le condizioni qui illustrate, consultare SMC (D-A34[A] [C], D-A44[A] [C], D-A54/A64, D-B54/B64, D-A59W, D-B59W) :q Il cavo del carico è ≥ 30m.w Usando PLC con gran portata di corrente.

    Circuiti interni box di protezione contatti( ): Se conforme a standard IEC

    CD-P11

    CD-P12

    Box di protezione contatti/Dimensioni (mm)

    Box di protezione contatti/Metodo di connessione

    Caratteristiche del box di protezione dei contatti Codice

    Tensione di carico

    CD–P11 CD–P12

    Lunghezza cavi– Lato connessione sensore 0.5m Lato connessione carico 0.5m

    100V AC max.

    25mA

    200V AC

    12.5mA

    24Vcc

    50mA

    Max. corrente di carico

    Per collegare un sensore al box di protezione contatti, collegare il cavo nel lato indicato come “SWITCH” sul box di protezione contatti al cavo del corpo del sensore.La lunghezza del cavo tra il corpo del sensore e il box di pro-tezione contatti deve essere entro il metro e devono essere sis-temati quanto più vicino possibile l’uno all’altro.Sensore

    Attivazione sensore (ON) Nota)

    Isteresi La differenza tra attivazione (ON) ela disattivazione(OFF) in un sensorereed è di ≤ 2mm e di un ≤1mm nei sensori allo stato solido.

    Disattivazione sensore (OFF)

  • 6-20

    Collegamento base

    � Stato Solido 3 fili NPN

    � Specifica per entrate a PLC con COM+3 fili, NPN

    � 3 fili

    2 fili

    � Specifiche per entrate a PLC con COM-3 fili, PNP

    � 2 fili con 2 sensori collegati in serie (AND) 2 fili con 2 sensori collegati in

    parallelo (OR)

    2 fili 2 fili

    3 fili (PNP)

    Collegare secondo le specifiche: il metodo diconnessione cambia in funzione delle entrate al PLC.

    Tensione sul carico in ON=Tensione di alimentaz.–Tensione residua X 2 unità =24V–4V X 2 pz. =16V

    Esempio) Alimentazione 24Vcc, caduta di tensione nel sensore: 4V

    Tensione sul carico in OFF=Corrente di carico X 2 unità X Impedenza di carico =1mA X 2 pz. X 3k� =6V

    Esempio)Impedenza carico 3k�, corrente di dispersione del sensore 1mA

    (Alimentazione diversa per sensore e carica).

    Sensore 1

    Sensore 2

    Carico

    Marrone Nero Blu

    Marrone Nero Blu

    Sensore 1

    Marrone

    Sensore 2

    Nero Blu

    Relè

    Relè

    Marrone Nero Blu

    Carico

    Relè contatto

    Sensore 1

    Sensore 2

    Marrone

    Blu

    Marrone

    Blu

    CaricoSensore 1

    Sensore 2

    Marrone

    Blu

    Marrone

    Blu

    Carico

    Circuito principale

    IC

    Marrone

    Nero

    Blu

    Carico

    Marrone

    Nero

    Blu

    Circuitoprincipale

    IC

    Carico

    Circuito principale

    IC

    Marrone

    Nero

    Blu

    Carico

    Circuito principale

    IC

    Marrone

    Blu

    Carico

    Marrone

    Blu

    Circuito principale

    IC

    Carico

    Sensore

    IN Nero

    COM

    Marrone

    Blu

    Sensore

    IN

    Blu COM

    Marrone

    Sensore

    IN Nero

    Circuito interno PLC COM

    Marrone

    Blu

    Circuito interno PLC

    Circuito interno PLC

    Circuito interno PLC

    Sensore

    IN Blu

    COM Marrone

    Esempi di collegamento in serie (AND) e in parallelo (OR)

    Esempi di collegamento a PLC (sequenziatori)

    � Sensori reed 0112 fili

    Circ

    uito

    di

    prot

    ezio

    nepe

    r LE

    D

    Marrone

    Blu

    Carico

    Circ

    uito

    di

    prot

    ezio

    ne

    per

    LED

    Marrone

    Blu Carico

    Collegamento AND per uscita NPN(Utilizzando relè)

    Sensore 1

    Marrone

    Sensore 2

    Nero Blu

    Carico

    Marrone Nero Blu

    Collegamento AND per uscita PNP(realizzata unicamente con sensori)

    Indicatore ottico quando entrambi i sensori sono su ON.

    Sensori stato solido

    2 sensori collegati in serie possono causare un malfunzionamento dovuto alla caduta di tensione sul carico nella posizione ON. I LED si illumineranno quando entrambi i sensori sono nella posizione ON.

    2 sensori collegati in parallelo possono causare un malfunzionamento dovuto all'aumento della tensione sul carico nella posizione OFF. Sensori reed Dato che non esiste corrente di dispersione, la tensione di carico non aumenterà in caso di passaggio alla posizione OFF. Tuttavia il LED potrebbe perdere intensità o non illuminarsi a causa di una dispersione e riduzione della corrente circolante, questo dipende del numero di sensori nella posizione ON.

    Collegamento OR per uscita NPN

    Istruzioni per l’usoMetodi di collegamento dei sensori/Esempi di collegamento

  • 6-21

    Sensori reedSensori genericiLED bicolore

  • 6-22

    Lunghezza cavi - Cavo vinilico antiolio, ø3.4, 0.2mm2, 3 fili (Marrone, Nero, Blu), 2 fili (Marrone, Blu), 0.5m Nota 1) Vedere dati tecnici comuni a p. 6-18.Nota 2) Vedere p. 6-18 per lunghezza cavi.

    Serie Attuatori ApplicabiliSerie

    CDJ2

    CDVJ

    CDLJ2

    CDM2/CDBM2/CDVM3, 5CDLM2

    CDG1/MGG

    CDLG1

    RSDG

    MGC

    MLGC/RHC/REC

    Diametro (mm)

    ø6, ø10, ø16

    ø10, ø16

    ø16

    ø20, ø25, ø32, ø40

    ø20, ø25, ø32, ø40, ø50, ø63

    ø20, ø25, ø32, ø40

    ø40, ø50

    ø20, ø25, ø32, ø40, ø50

    ø20, ø25, ø32, ø40

    Dati Tecnici PLC: Regolatore logico programmabileD-C7 (Con indicatore ottico)Modello sensori

    Applicazioni

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D-C8 (Senza indicatore ottico) Modello sensori

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    D-C73

    Relè/PLC

    24Vcc

    5 ÷ 40mA

    100Vca

    5 ÷ 20mA

    None

    ON: LED rosso acceso

    D-C76

    Circuito IC

    4 ÷ 8Vcc

    20mA

    0.8V

    D-C80

    Relè/PLC/Circuito IC

    ≤ 24V

    50mA

    48V

    40mA

    100V

    20mA

    -

    ≤ 1 (Comprende una lunghezza cavo di 3m)

    VcaVcc

    VcaVcc

    VcaVcc

    Nota) I valori medi delle temperature normali includono isteresi (Tolleranza ± 30%)

    Dimensioni

    Campo d'esercizio ( l Dimensioni) (mm)

    Serie Attuatori

    CDJ2CDVJCDLJ2CDM2/CDBM2/CDVM3, 5/CDLM2CDG1/MGGCDLG1RSDGMGCMLGC/RHC/REC

    Diametro66

    1077

    16777

    20

    788

    88

    25

    81010

    1010

    32

    899

    99

    40

    81010101010

    50

    10

    1010

    63

    11

    2.4V

    Sensori reed/Montaggio a fascetta

    D-C73/D-C76/D-C80

    Grommet

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Indicatore otticoD-C80: senza indicatore ottico

    Circuito interno( ): Se non conforme a standard IEC

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. e In caso di tensione di carico da 100VcaSi raccomanda di usare il box di protezione contatti nei casi menzionati sopra. Particolari sui box protezione contatti a p. 6-19.

    D-C73

    D-C76

    D-C80

    LED

    Sen

    sori

    reed

    Resistenza

    Diode zener

    Boxprotezionecontatti

    CD–P11

    CD–P12

    Marrone(Rosso)

    Blu(Nero)

    OUT(+) Marrone(Rosso)

    OUT(–) Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Cambio diodo flusso

    Nero OUT

    CC(+) Marrone(Rosso)

    CC(–) Blu

    Carico

    (+)

    (–)

    Ten

    sion

    e

    Sen

    sori

    reed

    Boxprotezionecontatti

    CD–P11

    CD–P12

    OUT(±) Marrone(Rosso

    OUT( ) Blu(Nero)

    ±

  • 6-23

    Serie attuatori applicabiliSerie

    CDM2, CDBM2, CDVM3/5, CDLM2

    CDG1, MGG

    CDLG1

    CDA1, CDBA1, CDV3, CDVS,CDLA, CDL1, CE2, CNA

    MGC

    MLGC, RHC, REC

    Diametro (mm)

    ø20, ø25, ø32, ø40

    ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

    ø20, ø25, ø32, ø40

    ø40, ø50, ø63, ø80, ø100

    ø20, ø25, ø32, ø40, ø50

    ø20, ø25, ø32, ø40

    Dati Tecnici PLC: Regolatore logico programmabileD-B5 (con indicatore ottico) Modello sensori

    Applicazioni

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D-B6 (Senza indicatore ottico) Modello sensori

    Applicazioni

    Tensione di carico

    Max. corrente di carico

    Box di protezione contatti

    Internal resistance

    cacc

    Lunghezza cavi Cavo vinilico antiolio, ø4, 0.3mm2, 2 fili (Marrone, Blu), 0.5m

    Nota 1) Vedere dati tecnici comuni a p. 6-18.

    Nota 2) Vedere p. 6-18 per lunghezza cavi.

    D-B53

    PLC

    24Vcc

    5 ÷ 50mA

    -

    2.4V

    ON: LED rosso acceso

    D-B54

    Relay/PLC

    24Vcc

    5 ÷ 50mA

    100Vca

    5 ÷ 25mA

    200Vca

    5 ÷ 12.5mA

    Incorporato

    2.4V

    D-B64

    Relè/PLC

    ≤ 24V

    Max.50mA

    100Vca

    Max.25mA

    200Vca

    Max.12.5mA

    Incorporato

    ≤ 10

    Dimensioni

    Campo d'esercizio ( l Dimensioni) (mm)

    Serie attuatori

    CDM2, CDBM2, CDVM3, 5CDLM2CDG1, MGGCDLG1CDA1, CDBA1, CDV3, CDVS,CDLA, CDL1, CE2, CNAMGCMLGC, RHC, REC

    Diametro20

    8

    88

    88

    25

    8

    1010

    1010

    32

    9

    99

    99

    40

    9

    1010

    9

    1010

    50

    10

    10

    10

    63

    11

    11

    80

    11

    11

    100

    11

    11

    Nota) I valori medi delle temerature normali includono isteresi ( 30% Tolleranza)

    Sensori reed/Montaggio a fascetta

    D-B53/D-B54/D-B64Grommet

    Circuito interno( ): Se non conforme a standard IEC

    D-B53

    D-B54

    D-B64

    Zener diode

    Sensori reed

    LED

    Resistenza OUT(–) Blu(Nero)

    OUT(+) Marrone Rosso

    Zener diode

    Sensori reed

    LED

    Resistenza Bobina d'arresto

    Soppressore di picchi

    OUT(–) ~ Blu(Nero)

    OUT(+) ~ Marrone Rosso

    Reed switch

    Bobina d'arresto

    Soppressori di picchi

    OUT( ) ~ Blu(Nero)

    OUT(±) ~ Marrone (Rosso)

    ±

    Campo d'operazione(Vedere tabella sotto.)

    Indicatore ottico

    senza indicatore ottico

  • 6-24

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø6, ø10, ø16

    ø10, ø16

    ø16

    ø20, ø25, ø32, ø40

    ø20, ø25, ø32, ø40, ø50, ø63

    ø20, ø25, ø32, ø40

    ø40, ø50

    ø20, ø25, ø32, ø40, ø50

    ø20, ø25, ø32, ø40

    CDJ2

    CDVJ

    CDLJ2

    CDM2, CDBM2, CDVM3, CDVM5, CDLM2

    CDG1, MGG

    CDLG1

    RSDG

    MGC MLGC, RHC, REC

    D–C73C (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–C73C

    Relè PLC

    24Vcc

    5 ÷ 40mA

    Nessuno

    ≤ 2.4V

    ON: LED rosso acceso

    D–C80C (Senza indicatore ottico) Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    D–C80C

    Relè PLC

    ≤ 24V

    50mA

    Nessuno

    ≤1� (compresa una lunghezza cavo di 3m)

    Serie attuatori Diametro

    6 6

    10 7 7

    16 7 7 7

    20 7 8 8 8 8

    25 8 10 10

    10 10

    32 8 9 9 9 9

    40 8 10 10 10 10 10

    50

    10

    10 10

    63

    11

    (mm)

    CDJ2 CDVJ CDLJ2 CDM2, CDBM2, CDVM3, CDVM5, CDLM2 CDG1, MGG CDLG1 RSDG MGC MLGC, RHC, REC

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Lunghezza cavi – Cavo vinilico antiolio, ø3.4, 0.2mm2 , 2 fili (marrone, blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18. Nota 3) Lunghezza cavi con connettore potrebbero essere consegnati con sensore.

    Vca Vcc

    Connettore

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. Si raccomanda di usare il box di protezione contatti nei casi menzionati sopra. Particolari sui box protezione contatti a p.6-19.

    PrecauzioneAvvertenze

    qVerificare che il connettore sia stato fis-sato adeguatamente. Se viene stretto in modo insufficiente la resistenza all’acqua risulterebbe compromessa.

    wParticolari a p.6-88.

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Indicatore ottico

    senza indicatore ottico

    Lunghezza cavi con connettore

    Circuito interno( ): Se non conforme a standard IEC

    Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Marrone(Rosso)

    OUT(–) Blu(Nero)

    OUT(+) Marrone(Rosso)

    Bobina d'arresto

    Box protezione contatti CD–P12

    DiodoZener Diodo Zener

    D-C73C

    D-C80C

    Boxprotezionecontatti CD–P11 CD–P12

    OUT(±) Marrone(Rosso)

    a OUT( ) Blu(Nero)

    ±

    Sen

    sori

    reed

    Sensori reed/Montaggio a fascetta

    D-C73C/D-C80C

  • 6-25

    Campo d'operazione(Vedere tabella sotto.)

    Posizione più sensibile

    Indicatore ottico

    ø est. cavo applicabile ø6.8 ÷ 9.6 ø est. cavo applicabile ø6.8 ÷ 11.5

    Campo d'operazione(Vedere tabella sotto.)

    Posizione più sensibile

    Vite ditenuta

    Vite ditenuta

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø40, ø50, ø63, ø80, ø100

    ø40, ø50, ø63, ø80, ø100, ø125, ø140, ø160

    ø125, ø140, ø160, ø180, ø200

    ø20, ø25, ø32, ø40

    CDA1, CDBA1, CDV3, CDVS, CDLA,

    CE2, CNA

    CDL1

    CDS1

    RHC

    D–A3(Con indicatore ottico) Box di collegamentoPLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–A33

    PLC

    24Vcc

    5 ÷ 50mA

    Nessuno

    24Vcc

    5 ÷ 50mA

    D–A34

    Relè PLC

    100Vca

    5 ÷ 25mA

    Incorporati

    200Vca

    5 ÷12.5mA

    ≤ 2.4V

    ON: LED rosso acceso

    D–A44(Con indicatore ottico) Terminale DINModello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    24Vcc

    5 ÷ 50mA

    D–A44

    Relè PLC

    100Vca

    5 ÷ 25mA

    Incorporati

    ≤ 2.4V

    ON: LED rosso acceso

    200Vca

    5 ÷ 12.5mA

    Nota 1) Vedere i dati tecnici comuni a p. 6-18.

    D–A3 D–A44

    Serie attuatori Diametro

    20

    9

    25

    10

    32

    9

    40 9 9

    10

    50

    10

    10

    63

    11

    11

    80

    11

    11

    100

    11

    11

    125

    10 10

    140

    10 10

    160

    10 10

    180

    10

    200

    10

    CDA1, CDBA1, CE2 CDV3, CDVS, CDLA CNA

    (mm)

    CDL1 CDS1 RHC Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Sensori reed/Montaggio a fascetta

    D-A33/D-A34/D-A44

    Box di collegamento: D-A3 Terminale DIN: D-A4

    Precauzione

    Circuito internoD-A33

    D-A34, D-A44

    Diodo Zener

    Sensori reed LED

    Resistenza

    OUT( – ) 2ºterminale

    OUT( + ) 1ºterminale

    Diode zener

    Sensori reed LED

    Resistenza

    Bobina d'arresto

    Soppressore di picchi

    OUT(+) 1ºterminale

    OUT(–) to2ºterminale

    Avvertenze

    q Usare cavi il cui ø est. sia compreso nel valore in figura in modo da non compromet-tere le prestazioni di resistenza all’acqua.

    wDopo il cablaggio verificare che le viti siano ben serrate.

  • 6-26

    Serie attuatori applicabili

    Dati tecnici PLC: Regolatore logico programmabile

    Serie

    CDM2, CDBM2, CDLM2

    Diametro (mm)

    ø20, ø25, ø32, ø40

    D–A3 � A(Con indicatore ottico) Box di collegamentoModello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–A44A(Con indicatore ottico) Terminale DINModello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–A33A PLC

    24Vcc

    5 ÷ 50mA

    Nessuno

    100Vca

    5 ÷ 25mA

    Relè PLC

    D–A34A

    Incorporati

    ≤ 2.4V

    ON: LED rosso acceso

    24Vcc

    5 ÷ 50mA

    200Vca

    5 ÷12.5mA

    Nota 1) Vedere i dati tecnici comuni a p. 6-18.

    24Vcc

    5 ÷ 50mA

    200Vca

    5 ÷12.5mA

    D–A44A Relè PLC

    100Vca

    5 ÷ 25mA

    Incorporati

    ≤ 2.4V

    ON: LED rosso acceso

    Campo d'operazione(Vedere tabella sotto.) Posizione più sensibile

    (ø est. cavo applicabile

    Vite di tenuta

    ø6.8 ÷ 9.6)

    (ø est. cavo applicabile ø6.8 ÷ 11.5)

    Posizione più sensibile

    Vite di tenuta

    Campo d'operazione (Vedere tabella sotto)

    Sensori reed/Montaggio a fascetta

    D-A33A/D-A34A/D-A44A

    Box di collegamento: D-A3�A Terminale DIN: D-A44A

    Dimensioni

    Precauzione

    Avvertenzeenza all’acqua.

    wDopo il cablaggio verificare che le viti siano ben serrate.

    q Usare cavi il cui ø est. sia compreso nel valore in figura in modo da non compromettere le prestazioni di resist-

    D-A3�A D-A44A

    Campo di funzionamento ( l Dimensione) (mm) Serie attuatori

    CDM2, CDBM2, CDLM2

    Diametro 20 8

    25 8

    32 9

    40 9

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Circuito internoD-A34A, D-A44A

    D-A33A

    Diodo Zener

    Sensori reed LED

    Resistenza

    OUT(–) 2º terminale

    OUT(+) 1º terminale

    Diodo Zener

    Sensori Reed LED

    Resistenza

    Bobina d'arresto

    Soppressore di picchi

    OUT(+) 1ºterminale

    OUT(–) to2ºterminale

  • 6-27

    Serie attuatori applicabili

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø10, ø16

    ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100, ø125, ø140, ø160

    Montaggio piastra ø10, ø16, ø20, ø25, ø32, Sede del montaggio ø16, ø20, ø25, ø32

    ø6, ø10, ø15, ø20, ø25, ø32, ø40

    ø16, ø20, ø32, ø40, ø50

    ø25, ø32, ø40, ø50, ø63

    ø12, ø20, ø32, ø40, ø50, ø63

    ø20, ø25, ø32, ø40, ø50, ø63

    ø32, ø40

    CDJ2, CDVJ

    CDQ2

    CDXW

    CDY1S, CY1L

    RSDQ

    MDU

    CE1

    MK, MK2

    CXT

    Serie attuatori Diametro

    6 6 6

    10 8 6 6 6

    12

    10

    10

    15

    6 6

    16 9 12 6 6

    20

    12 6 6 6 6 12

    12 12

    25

    12 6 6 6 6 12 13

    12

    32

    12 6 6 6 6 12 13 12 12 12

    40

    11

    6 6 11 13 11 11 11

    50

    10

    10 13 10 10

    63

    12

    13 12 12

    80

    12

    100

    13

    125

    13

    140

    13

    160

    13 CDJ2, CDVJ CDQ2 CDXW

    CDY1S CY1L RSDQ MDU CE1 MK, MK2 CXT

    (mm)

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    BP

    Dati tecnici

    Dimensioni

    D–A7 (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    24Vcc

    5 ÷ 40mA

    Nessuno

    ≤ 2.4V

    ON: LED rosso acceso

    100Vca

    5 ÷ 20mA

    D–A7

    Relè PLC

    200Vca

    5 ÷ 10mA

    D–A73

    Relè PLC

    D–A80

    Relè, circuito IC, PLC

    40mA

    Nessuno

    ≤1� (compresa una lunghezza cavo di 3m)

    D–A8 (Senza indicatore ottico) Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    Lunghezza cavi – Cavo vinilico antiolio, ø3.4, 0.2mm2 , 2 fili (marrone, blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    50mA 20mA

    ≤ 24V Vca Vcc 48V Vca Vcc 100V

    Vca Vcc

    Posizione più sensibile

    Lunghezza cavi 0.2mm2 X 2 filiRivestimento grigio chiaro

    Indicatore ottico

    senza indicatore ottico

    tipo

    Sensori reed/Montaggio su guida

    D-A72/D-A73/D-A80

    Grommet Connessione elettrica perpendico-

    lare

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. e In questo caso la tensione di carico è 100 o 200VcaSi raccomanda di usare il box di protezione contatti nei casi menzionati sopra.D-A72 deve essere usato con box di protezione contatti.Particolari a p.6-19.

    D-A72

    D-A73

    D-A80

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo zener

    Boxprotezionecontatti

    CD–P11

    CD–P12

    Marrone(Rosso)

    Blu(Nero)

    OUT(+) Marrone(Rosso)

    a

    OUT(–) Blu(Nero)

    Sen

    sori

    reed

    Boxprotezionecontatti

    CD–P11 CD–P12

    OUT(±) Marrone(Rosso)

    a OUT( ) Blu(Nero)

    ±

    Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo zener

    Marrone(Rosso)

    OUT Blu(Nero)

    OUT Marrone(Rosso) Bobina

    d'arresto

    Scatola protezione contatti CD–P11

    Soppressoredi picchi

    a

    Circuito interno( ): Se non conforme a standard IEC

  • 6-28

    senza indicatore ottico

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Indicatore ottico

    Serie attuatori applicabili

    Campo di funzionamento (l Dimensione)

    Serie Diametro (mm)

    ø10, ø16

    ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100, ø125, ø140, ø160

    Montaggio piastra ø10, ø16, ø20, ø25, ø32, Sede del montaggio ø16, ø20, ø25, ø32

    ø6, ø10, ø15, ø20, ø25, ø32, ø40

    ø16, ø20, ø32, ø40, ø50

    ø25, ø32, ø40, ø50, ø63

    ø12, ø20, ø32, ø40, ø50, ø63

    ø20, ø25, ø32, ø40, ø50, ø63

    ø32, ø40

    CDJ2, CDVJ

    CDQ2

    CDXW

    CDY1S, CY1L

    RSDQ

    MDU

    CE1

    MK, MK2

    CXT

    Serie attuatori Diametro

    6

    6 6

    10 8 6 6 6

    12

    10

    10

    15

    6 6

    16 9 12 6 6

    20

    12 6 6 6 6 12

    12 12

    25

    12 6 6 6 6 12 13

    12

    32

    12 6 6 6 6 12 13 12 12 12

    40

    11

    6 6 11 13 11 1111

    50

    10

    10 13 10 10

    63

    12

    13 12 12

    80

    12

    100

    13

    125

    13

    140

    13

    160

    13

    CDJ2, CDVJ CDQ2 CDXW

    CDY1S CY1L RSDQ MDU CE1 MK, MK2 CXT

    (mm)

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    BP

    Dati tecnici

    Dimensioni

    D–A7 � H (con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    24Vcc

    5 ÷ 40mA

    ≤ 2.4V

    ON: LED rosso acceso

    100Vca

    5 ÷ 20mA

    D–A72H

    Relè PLC

    200Vca

    5 ÷ 10mA

    D–A76H

    Circuito IC

    4 ÷ 8V cc

    20mA

    0.8V o meno)

    D–A73H

    Relè PLC

    Nessuno

    D–A80H

    Relè, circuito IC, PLC

    40mA

    Nessuno

    ≤ 1� (compresa una lunghezza cavo di 3m)

    D–A80H (Senza indicatore ottico) Modello sensore

    Applicazioni

    Tensione di carico

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    Lunghezza cavi –– Cavo vinilico antiolio, 0.2mm 2 , 2 fili (Marrone, Blu), 3 fili (Marrone, Nero, Blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    50mA 20mA

    ≤ 24V Vca Vcc 48V Vca Vcc 100V

    Vca Vcc

    Sensori reed/Montaggio su guida

    D-A7 �H/D-A80HGrommet

    Connessione elettrica in linea

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. e In questo caso la tensione di carico è 100 o 200VcaSi raccomanda di usare il box di protezione contatti nei casi menzionati sopra.D-A72 deve essere usato con box di protezione contatti.Particolari a p.6-19.

    D-A72H

    D-A73H

    D-A76H

    D-A80H

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo zener

    Boxprotezionecontatti

    CD–P11

    CD–P12

    Marrone(Rosso)

    Blu(Nero)

    OUT(+) Marrone(Rosso)

    a

    OUT(–) Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo anti inversione di flusso

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Carico

    (+)

    (–)

    Ten

    sion

    e (V

    cc)

    Sen

    sori

    reed

    Boxprotezionecontatti

    CD–P11 CD–P12

    OUT(±) Marrone(Rosso)

    a OUT( ) Blu(Nero)

    ±

    Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo zener

    Marrone(Rosso)

    OUT Blu(Nero)

    OUT Marrone(Rosso) Bobina

    d'arresto

    Box protezione contatti CD–P11

    Soppressoredi picchi

    a

    Circuito interno( ): Se non conforme a standard IEC

  • 6-29

    Sensori reed/Montaggio su guida

    D-A73C/D-A80CConnettore

    D-A73C

    D-A80C

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. Si raccomanda di usare il box di protezione contatti nei casi menzionati sopra. Particolari sui box protezione contatti a p.6-19.

    Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diode zener

    Marrone(Rosso)

    OUT(–) Blu(Nero)

    OUT(+) Marrone(Rosso)

    Bobina d'arresto

    Box protezione contatti CD–P12

    Zener diode

    Sen

    sori

    reed

    Boxprotezionecontatti

    CD–P11

    CD–P12

    OUT(±) Marrone(Rosso)

    a OUT( ) Blu(Nero)

    ±

    Serie attuatori applicabili

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø10, ø16

    ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100, ø125, ø140, ø160

    Montaggio piastra ø10, ø16, ø20, ø25, ø32, Sede del montaggio ø16, ø20, ø25, ø32

    ø6, ø10, ø15, ø20, ø25, ø32, ø40

    ø16, ø20, ø32, ø40, ø50

    ø25, ø32, ø40, ø50, ø63

    ø16, ø20, ø32, ø40, ø50

    ø20, ø25, ø32, ø40, ø50, ø63

    ø32, ø40

    CDJ2, CDVJ

    CDQ2

    CDXW

    CDY1S, CY1L

    RSDQ

    MDU

    CE1

    MK, MK2

    CXT

    Serie attuatori Diametro

    6

    6 6

    10 8 6 6 6

    12

    10

    10

    15

    6 6

    16 9 12 6 6

    20

    12 6 6 6 6 12

    12 12

    25

    12 6 6 6 6 12 13

    12

    32

    12 6 6 6 6 12 13 12 12 12

    40

    11

    6 6 11 13 11 11 11

    50

    10

    10 13 10 10

    63

    12

    13 12 12

    80

    12

    100

    13

    125

    13

    140

    13

    160

    13 CDJ2, CDVJ CDQ2 CDXW

    CDY1S CY1L RSDQ MDU CE1 MK, MK2 CXT

    (mm)

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    BP

    Dati tecnici

    Dimensioni

    D–A73C (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–A73C

    Relè PLC

    24Vcc

    5 ÷ 40mA

    Nessuno

    ≤ 2.4V

    ON: LED rosso acceso

    D–A80C

    Relè, circuito IC, PLC

    50mA

    Nessuno

    ≤ 1� (compresa una lunghezza cavo di 3m)

    D–A80C (Senza indicatore ottico) Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.2mm2 , 2 fili (marrone, blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18. Nota 3) Lunghezza cavi con connettore potrebbero essere consegnati con sensore.

    24V Vca Vcc Precauzione

    AvvertenzeqVerificare che il connettore sia stato fis-

    sato adeguatamente. Se viene stretto in modo insufficiente la resistenza all’acqua risulterebbe compromessa.

    wParticolari a p.6-88.

    Circuito interno( ): Se non conforme a standard IEC

    senza indicatore ottico

    Campo d'operazione(Vedere tabella sotto.)

    Posizione più sensibile

    Indicatore ottico

    Lunghezza cavi con connettore

  • 6-30

    Sensori reed/Montaggio con tiranti

    D-A5 �/D-A6 �Grommet

    D-A53

    D-A54

    D-A56

    D-A64

    D-A67

    Diodo Zener

    Sensori reed

    LED

    Resistenza

    OUT(–) Blu(Nero)

    OUT(+) Marrone(Rosso)

    Diodo Zener

    Sensori reed

    LED

    Resistenza

    Bobina d'arresto

    Soppressore di picchi

    OUT(–) Blu(Nero)

    OUT(+) Marrone(Rosso)

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo antiinversione di flusso

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Carico

    (+)

    (–)

    Ten

    sion

    e

    Sensore Reed

    Bobina d'arresto

    Soppressore di picchi

    OUT( ) Blu(Nero)

    OUT(±) Marrone(Rosso)

    ±

    Sensore Reed

    OUT(±) Marrone(Rosso)

    OUT( ) Blu(Nero)

    ±

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø40, ø50, ø63, ø80, ø100

    ø40, ø50, ø63, ø80, ø100, ø125, ø140, ø160

    ø125, ø140, ø160, ø180, ø200

    ø32, ø40, ø50, ø63, ø80, ø100

    CDA1, CDBA1, CDV3, CDVS, CDLA, CE2, CNA

    CDL1

    CDS1

    MDB, MDBB

    D–A5 (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    e campo

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–A53

    PLC

    24Vcc

    5 ÷ 50mA

    Nessuno

    24Vcc

    5 ÷ 50mA

    D–A54

    Relè PLC

    100Vca

    5 ÷ 25mA

    Incorporati

    200Vca

    5 ÷ 12.5mA

    D–A56

    Circuito IC

    4 ÷ 8Vcc

    20mA

    Nessuno

    ≤ 0.8V

    D–A6 (Senza indicatore ottico) Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    ≤ 24V 200Vca

    12.5mA

    D–A67

    PLC/circuito IC

    MAX. 24Vcc

    30mA

    Nessuno

    ≤1� (Compresa una lunghezza cavi di 3m)

    D–A64

    Relè PLC

    100Vca

    25mA

    Incorporati

    ≤ 10�

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.3mm2 , 2 fili (marrone, blu), 0.5m o 4, 0.2mm 2 , , 0113 fili (marrone, nero, blu), 0.5m

    Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    Serie attuatori 32

    9

    40 9

    9 9

    50 10

    10

    10

    63 11

    11

    11

    80 11

    11

    11

    100 11

    11

    11

    125

    10 10

    140

    10 10

    160

    10 10

    180

    10

    200

    10

    CDA1, CDBA1, CDV3, CNA, CDVS, CDLA, CE2

    (mm)

    CDL1 CDS1 MDB , MDBB Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    2.4V

    ON: LED rosso acceso

    Vca Vcc

    50mA

    Diametro

    Circuito interno( ): Se non conforme a standard IEC

    senza indicatore ottico

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Indicatore ottico

  • 6-31

    (ø est. cavo applicabile ø6.8 ÷ 9.6)

    Campo d'operazione(Vedere tabella sotto.)

    Indicatore ottico Posizione più sensibile

    BrugolaVite di tenuta

    Brugola

    Brugola

    BrugolaVite di tenuta

    Campo d'operazione(Vedere tabella sotto.)

    Posizione più sensibile

    (ø est. cavo applicabile ø6.8 ÷ 11.5)

    Serie attuatori applicabili

    Dati tecnici PLC: Regolatore logico programmabile

    Serie

    CDA1, CDBA1, CDV3, CDVS, CDLA, CDL1, CE2, CNA

    Diametro (mm)

    ø40, ø50, ø63, ø80, ø100

    D–A3 � C(Con indicatore ottico) Box di collegamentoModello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–A44C(Con indicatore ottico) Terminale DINModello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    ≤ 2.4V

    ON: LED rosso acceso

    D–A44C Relè PLC

    100Vca

    5 ÷ 25mA

    Incorporati

    ≤ 2.4V

    ON: LED rosso acceso

    D–A33C PLC

    D–A34C Relè PLC

    100Vca

    5 ÷ 25mA

    Incorporati

    24V ca

    5 ÷ 50mA

    Nessuno

    24Vcc

    5 ÷ 50mA

    200Vca

    5 ÷ 12.5mA

    Nota 1) Vedere i dati tecnici comuni a p. 6-18.

    24Vcc

    5 ÷ 50mA

    200Vca

    5 ÷ 12.5mA

    Sensori reed/Montaggio con tiranti

    D-A33C/D-A34C/D-A44C

    Box di collegamento: D-A3�C Terminale DIN : D-A44C

    Circuito internoD-A33C

    D-A34C, D-A44C

    Dimensioni

    D-A3�C D-A44C

    Campo d'esercizio ( l Dimensioni) Dimensioni (mm)

    Serie attuatori

    CDA1, CDBA1, CDV3, CDVS, CDLA, CDL1, CNA

    Diametro (mm)40

    9

    50

    10

    63

    11

    80

    11

    100

    11

    Nota) I valori medi delle temperature normali includonoisteresi. ( 30% di tolleranza)

    Codici sensori

    D-A3�C-4, D-A44C-4D-A3�C-5, D-A44C-5D-A3�C-6, D-A44C-6D-A3�C-8, D-A44C-8D-A3�C-10, D-A44C-10

    Diametro (mm)

    40506380

    100

    C

    4452647892

    HW

    697791

    107 121

    H

    58(67.5)59(68.5)61.5(71)65(74.5)68(77.5)

    H'

    50.5(60)51.5(61)53(62.5)54.5(64)57.5(67)

    T

    7.5 8.5 10.512.515.5

    T'

    6.5 6.5 7.5 9.5 9.5

    M5 X 16

    M5 X 20

    M5 X 25

    ∗ ( ): Valori per D-A44C

    Z

    Diodo Zener

    Sensori reed LED

    Resistenza OUT(–) 2º terminale

    OUT(+) 1º terminale

    Diodo Zener

    Sensori reed LED

    Resistenza

    Bobina d'arresto

    Soppressore di picchi

    OUT(+) 1ºterminale

    OUT(-) 2ºterminale Precauzione

    Avvertenzeenza all’acqua.

    wDopo il cablaggio verificare che le viti siano ben serrate.

    q Usare cavi il cui ø est. sia compreso nel valore in figura in modo da non compromettere le prestazioni di resist-

  • 6-32

    senza indicatore ottico

    Posizione più sensibile

    Indicatore ottico

    Vite di fissaggio

    Campo d'operazione(Vedere tabella sotto.)

    Serie Attuatori Applicabili

    CDU

    CDQS

    CDQ2

    MY1

    MXU

    MXW

    MXF

    MXS/MXQ

    ø6, ø10, ø16, ø20, ø25, ø32

    ø12, ø16, ø20, ø25

    ø32, ø40, ø50, ø63, ø80, ø100

    ø16, ø20

    ø6, ø10, ø16

    ø8, ø12, ø16, ø20, ø25

    ø8, ø12, ø16, ø20

    ø6, ø8, ø12, ø16, ø20, ø25

    Dati Tecnici PLC: Regolatore logico programmabileD-A90 (Senza indicatore ottico)Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    D-A93/D-A96 (Con indicatore ottico)Modello sensore

    Applicazioni

    Tensione di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    Dimensioni

    *Non applicabile per CDQP2

    *

    Lunghezza cavi D-A90/D-A93D-A96Nota 1) Vedere i dati tecnici comuni a p. 6-18.Nota 2) Vedere lunghezza cavi a p. 6-18.

    Cavo vinilico antiolio, ø2.7, 0.18mm2 X 2fili (Marrone, Blu), 0.5mCavo vinilico antiolio, ø2.7, 0.15mm2 X 3fili (Marrone, Nero, Blu), 0.5m

    D-A90

    Circuito IC/Relè/PLC

    ≤ 24V

    50mA

    -

    ≤ 1 (Compresa una lunghezza cavi di 3m)

    ≤ 48V

    40mA

    ≤ 100V

    20mA

    D-A93

    Relè/PLC

    24Vcc

    5 ÷ 40mA

    -

    2.4V (fino a 20mA)/ 3V (fino a 40mA)

    ON: LED rosso acceso

    100Vca

    5 ÷ 20mA

    D-A96

    Circuito IC

    4 ÷ 8Vcc

    20mA

    0.8V

    Campo d'esercizio (l Dimensioni) (mm)Serie

    attuatori

    CDUCDQSCDQ2MY1MXUMXWMXFMXS

    Diametro65

    5

    4.5

    8

    64.55

    106

    6

    12

    6

    656

    169

    7.5

    59

    8.567

    201110

    5

    1078

    2512.510

    10

    8

    3214

    9.5

    40

    9.5

    50

    9.5

    63

    11.5

    80

    9

    100

    11.5

    Campo d'esercizio ( l Dimensioni) (mm)Serie

    attuatori

    MXQMXPMTSCXTMKMK2RSQCEPCY1R

    Diametro6

    4.5

    9

    85

    10

    5

    13

    1265

    66

    5

    15

    8

    1675

    7.57.5

    208

    7.510

    6.56

    259

    810

    32

    79.5

    9.59.5

    40

    89.5

    9.59.5

    50

    9.59.5

    63

    11.5

    Nota) I valori medi delle temperature normali includono isteresi (30% di tolleranza)

    VcaVcc

    VcaVcc

    VcaVcc

    Serie Diametro (mm)

    MXP

    MTS

    CXT

    MK

    MK2

    RSQ

    CEP

    CY1R

    ø10, ø12, ø16

    ø20, ø25, ø32, ø40

    ø12, ø16, ø20, ø25, ø32, ø40

    ø12, ø16

    ø32, ø40, ø50, ø63

    ø12, ø32, ø40, ø50

    ø12, ø20

    ø6, ø10, ø15, ø20

    Serie Diametro (mm)

    Max. corrente di caricoe campo corrente di carico

    Sensori reed/Montaggio diretto

    D-A90/D-A93/D-A96

    Grommet Connessione elettrica in linea

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. e In questo caso la tensione di carico è 100 VcaSi raccomanda di usare il box di protezione contatti nei casi menzionati sopra.Particolari a p.6-19.

    D-A90

    D-A93

    AvvertenzeqFissare il sensore con l’apposita vite collocata nel corpo. Altre viti potrebbero dan-neggiarlo.

    D-A96

    Precauzione

    Sen

    sori

    reed

    Scatolaprotezionecontatti

    CD–P11 CD–P12

    OUT(±) Marrone(Rosso)

    a OUT( ) Blu(Nero)

    ±

    LED

    Sen

    sori

    reed

    Resistenza

    Cambio diodo flusso

    OUT Nero(Bianco)

    DC(+) Marrone(Rosso)

    DC(–) Blu(Nero)

    Carico

    (+)

    (–)

    Ten

    sion

    e

    Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diode zener

    Marrone(Rosso) Scatolaprotezionecontatti

    CD–P11

    CD–P12

    OUT(+) Marrone(Rosso)

    a

    OUT(–) Blu(Nero)

    Circuito interno( ): Se non conforme a standard IEC

    ( ): D-A93

  • 6-33

    senza indicatore ottico

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Indicatore ottico

    Vite di fissaggio

    Sensori reed/Montaggio diretto

    D-A90V/D-A93V/D-A96V

    D-A90V

    D-A93V

    D-A96V

    Sen

    sori

    reed

    Boxprotezionecontatti

    CD–P11 CD–P12

    OUT(±) Marrone(Ross

    a OUT( ) Blu(Nero)

    ±

    Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo zener

    Marrone(Rosso) Boxprotezionecontatti

    CD–P11

    CD–P12

    OUT(+) Marrone(Rosso)

    a

    OUT(–) Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo antiinversione di flusso

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Carico

    (+)

    (–)

    Ten

    sion

    e

    Grommet Connessione elettrica perpendi-

    colare

    Circuito interno( ): Se non conforme a standard IEC

    AvvertenzeqFissare il sensore con l’apposita vite collocata nel corpo. Altre viti potrebbero dan-neggiarlo.

    Precauzione

    Dati Tecnici PLC: Regolatore logico programmabileD-A90V (Senza indicatore ottico)

    D-A93V/D-A96V (Con indicatore ottico)

    D-A90V

    Circuito IC/Relè/PLC

    ≤ 24V

    50mA

    -

    ≤ 1 (Comprende lunghezza cavi di 3m)

    ≤ 48V

    40mA

    ≤ 100V

    20mA

    D-A93V

    Relè/PLC

    24Vcc

    5 ÷ 40mA

    -

    ≤ 2.7V

    ON: LED rosso acceso

    100Vca

    5 ÷ 20mA

    D-A96V

    Circuito IC

    4 ÷ 8Vcc

    20mA

    ≤ 0.8V

    VcaVcc

    VcaVcc

    VcaVcc

    Serie Attuatori Applicabili

    CDU

    CDQS

    CDQ2

    MY1

    MXU

    MXW

    MXF

    MXS/MXQ

    ø6, ø10, ø16, ø20, ø25, ø32

    ø12, ø16, ø20, ø25

    ø32, ø40, ø50, ø63, ø80, ø100

    ø16, ø20

    ø6, ø10, ø16

    ø8, ø12, ø16, ø20, ø25

    ø8, ø12, ø16, ø20

    ø6, ø8, ø12, ø16, ø20, ø25

    *Non applicabile per CDQP2

    *

    Serie Diametro (mm)

    MXP

    MTS

    CXT

    MK

    MK2

    RSQ

    CEP

    CY1R

    ø10, ø12, ø16

    ø20, ø25, ø32, ø40

    ø12, ø16, ø20, ø25, ø32, ø40

    ø12, ø16

    ø32, ø40, ø50, ø63

    ø12, ø32, ø40, ø50

    ø12, ø20

    ø6, ø10, ø15, ø20

    Serie Diametro (mm)

    Dimensioni

    (mm)

    CDUCDQSCDQ2MY1MXUMXWMXFMXS

    65

    5

    4.5

    8

    64.55

    106

    6

    12

    6

    656

    169

    7.5

    59

    8.567

    201110

    5

    1078

    2512.510

    10

    8

    3214

    9.5

    40

    9.5

    50

    9.5

    63

    11.5

    80

    9

    100

    11.5

    (mm)

    MXQMXPMTSCXTMKMK2RSQCEPCY1R

    64.5

    9

    85

    10

    5

    13

    1265

    66

    5

    15

    8

    1675

    7.57.5

    208

    7.510

    6.56

    259

    810

    32

    79.5

    9.59.5

    40

    89.5

    9.59.5

    50

    9.59.5

    63

    11.5

    Lunghezza caviD-A90V/D-A93VD-A96VNota 1) Vedere dati tecnici comuni a p. 6-18.Nota 2) Vedere lunghezza cavi a p. 6-18.

    Cavo vinilico antiolio, ø2.7, 0.18mm2 X 2fili (Marrone, Blu), 0.5mCavo vinilico antiolio, ø2.7, 0.15mm2 X 3fili (Marrone, Nero, Blu), 0.5m

    Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Circuitio di protezione contatti

    Resistenza interna

    Modello sensore

    Applicazioni

    Tensioni di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    Campo d'esercizio ( l Dimensioni)Serie

    attuatoriDiametro

    Campo d'esercizio ( l Dimensioni)Serie

    attuatoriDiametro

    Nota) I valori medi delle temerature normali includono isteresi (30% di tolleranza)

    Max. corrente di carico ecampo corrente di carico

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. e In questo caso la tensione di carico è 100 VcaSi raccomanda di usare il box di protezione contatti nei casi menzionati sopra.Particolari a p.6-19.

  • 6-34

    Sen

    sori

    reed

    OUT(±)‚ Marrone(Rosso)

    a

    OUT( ) Blu(Nero)

    Boxprotezionecontatti

    CD–P11

    CD–P12

    ± OUT( )

    ±

    OUT(±)

    Linea nera

    Sensori reed/Montaggio diretto

    D-90/D-97

    D-90

    D-97

    Dimensioni

    D-90

    Campo di funzionamento ( l Dimensione) (mm)

    Serie attuatori

    CDU

    CDJP � D

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Senza piastra schermo Con piastra schermo

    6 5.5 5.5

    10 8 7

    15 9

    16 9 7

    20

    11 8

    25

    12 8

    32

    14 9

    Diametro

    Serie attuatori applicabili Serie

    CDJP– � D CDU

    Diametro (mm)

    ø6, ø10, ø15

    ø6, ø10, ø16, ø20, ø25, ø32

    Dati tecnici PLC: Regolatore logico programmabile D–90 (Senza indicatore ottico)

    D–97 (Con indicatore ottico) Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Cadute interne di tensione

    Indicatore ottico

    Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Resistenza interna

    Lunghezza cavi –– Cavo parallelo vinilico, 0.2mm2 , 2 fili, 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    D–97 Relè PLC

    24Vcc

    5 ÷ 40mA

    ≤ 2.4V

    ON: LED rosso acceso

    D–90 Relè, circuito IC, PLC

    50mA

    ≤ 1� (compresa una lunghezza cavo di 3m)

    Vca Vcc 5V

    Vca Vcc 12V

    Vca Vcc 24V

    D-97

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Campo d'operazione (Vedere tabella sotto.)

    (Negativo) indicazione di polarità Linea nera

    Indicatore ottico

    Posizione più sensibile

    LED

    Sen

    sori

    reed

    Resistenza

    Diode zener

    Bobina d'arresto

    Box protezione contatti CD–P12

    Linea nera

    OUT(+) Marrone(Rosso)

    OUT(–) Blu(Nero)

    DiodoZener

    OUT(+)

    OUT(–)

    a

    Grommet Cavi:filo parallelo

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. Si raccomanda di usare il box di protezione contatti nei casi menzionati sopra. Particolari sui box protezione contatti a p.6-19.

    Circuito interno( ): Se non conforme a standard IEC

  • 6-35

    Indicatore ottico

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Serie attuatori applicabili Serie

    CDJP � D CDU

    Diametro (mm)

    ø6, ø10, ø15

    ø6, ø10, ø16, ø20, ø25, ø32

    Dati tecnici PLC: Regolatore logico programmabile D–90 A (Senza indicatore ottico)

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Cadute interne di tensione

    Indicatore ottico

    D–93A (Con indicatore ottico)

    Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Resistenza interna

    Lunghezza cavi –– Cavo vinilico antiolio, 0.2mm2 , 2 fili (marrone, blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    D–93A Relè PLC

    ≤ 2.4V

    ON: LED rosso acceso

    D–90A Relè, circuito IC, PLC

    ≤ 1� (compresa una lunghezza cavo di 3m)

    20mA

    50mA

    24Vcc

    5 ÷ 40mA

    100Vca

    5 ÷ 20mA

    Vca Vcc 5V

    Vca Vcc 12V

    Vca Vcc 24V

    Vca Vcc 100V

    Sensori reed/Montaggio diretto

    D-90A/D-93A

    D-90A

    D-93A

    D-90A

    Campo di funzionamento ( l Dimensione) (mm)

    Serie attuatori

    CDU

    CDJP � D

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Senza piastra schermo Con piastra schermo

    6 5.5 5.5

    10 8 7

    15 9

    16 9 7

    20

    11 8

    25

    12 8

    32

    14 9

    Diametro

    D-93A

    Sen

    sori

    reed

    Boxprotezionecontatti

    CD–P11 CD–P12

    OUT(±) Marrone(Rosso)

    a OUT( ) Blu(Nero)

    ±

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo zener

    Boxprotezionecontatti

    CD–P11

    CD–P12

    Marrone (Rosso)

    Blu (Nero)

    OUT(+) Marrone(Rosso)

    a

    OUT(–) Blu(Nero)

    Grommet Cavo con forte isolamento

    Circuito interno( ): Se non conforme a standard IEC

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. e In questo caso la tensione di carico è 100 VcaSi raccomanda di usare il box di protezione contatti nei casi menzionati sopra.Particolari a p.6-19.

    Dimensioni

  • 6-36

    Sensori reed/Montaggio diretto

    D-Z73/D-Z76/D-Z80

    D-Z73

    D-Z76

    D-Z80

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo zener

    Boxprotezionecontatti

    CD–P11

    CD–P12

    Marrone(Rosso)

    Blu(Nero)

    OUT(+) Marrone(Rosso)

    a

    OUT(–) Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo antiinversione di flusso

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc( – ) Blu(Nero)

    Carico

    (+)

    (–)

    Ten

    sion

    e

    Sen

    sori

    reed

    Boxprotezionecontatti

    CD–P11 CD–P12

    OUT(±) Marrone(Rosso)

    a OUT( ) Blu(Nero)

    ±

    Dati tecnici

    Dimensioni

    D–Z7 (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente carico e campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–Z73

    Relè PLC

    ≤2.4V (Fino a 20mA)/≤ 3V (Fino a 30mA)

    24Vcc

    5 ÷ 40mA

    100Vca

    5 ÷ 20mA

    Nessuno

    ON: LED rosso acceso

    D–Z76

    Circuito IC

    4 ÷ 8Vcc

    20mA

    ≤ 0.8V

    D–Z80

    Relè, circuito IC, PLC

    40mA

    Nessuno

    ≤ 1� (compresa una lunghezza cavo di 3m)

    D–Z8 (Senza indicatore ottico) Modello sensore

    Applicazione

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.2mm2 , 3 fili (Marrone, Nero, Blu), 2 fili (Marrone, Blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    50mA 20mA

    Campo di funzionamento ( l Dimensione)

    Serie attuatori Diametro

    6 9

    10 7 8

    12 7.5

    7.5

    15 9 6

    16 8.5

    10

    20 9.5 9 10 8.5

    6

    25 9.5 9 10

    12 12 12

    6 9

    32 11 11 10.5 7 12 12 12

    9 9

    40 11

    10.5

    12 12 12

    13.5

    11

    50 11

    10.5 9.5 12 12

    11

    63 13

    11.5 10.5 12 12

    12

    11

    80 13

    11.5 11.5 12

    100 14

    12

    12

    13

    (mm)

    MGQ, MVGQ CXS MGP RSH MY1B MY1M, MY1C MY1H, ML2B MGF CY1H CY1R

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Serie attuatori applicabili Serie Diametro (mm)

    ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

    ø6, ø10, ø15, ø20, ø25, ø32

    ø20, ø32, ø50, ø63, ø80

    ø25, ø32, ø40, ø50, ø63, ø80, ø100

    ø25, ø32, ø40, ø50, ø63

    ø25, ø32, ø40

    ø40, ø63, ø100

    ø10, ø15, ø20, ø25, ø32

    MGQ, MVGQ, MGP

    CXS

    RSH

    MY1B

    MY1M, MY1C, CY1R

    MY1H, ML2B

    MGF

    CY1H

    Vca Vcc ≤ 24V

    Vca Vcc ≤ 48V

    Vca Vcc ≤ 100V Tensione di carico

    Grommet

    Circuito interno( ): Se non conforme a standard IEC

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. e In questo caso la tensione di carico è 100 VcaSi raccomanda di usare il box di protezione contatti nei casi menzionati sopra.Particolari a p.6-19.

    Campod'operazione

    Posizione più sensibile

    Vite di montaggio per sensoreVite di fissaggio

    Indicatore ottico

    Campo d'operazione

    Posizione più sensibile

    Vite di montaggio per sensoreVite di fissaggio

    Indicatore ottico

    Indicatore ottico senza indicatore ottico

    senzaindicatore ottico

    D-Z73 D-Z76, Z80

  • 6-37

    Diametro

    20, 30, 50, 80, 100

    20, 30

    7, 20

    Regolazione sensore

    Vedere a p.1.0-19

    Vedere a p.1.0-19

    Vedere a p.1.8-29

    CDRB1

    CDRBU

    MDSUB

    D-R731/D-R732 D-R801/D-R802

    Relè, PLC Relè, circuito IC, PLC

    PLC: Regolatore logico programmabile

    D-R73 � (con LED) D-R80 � (senza LED)

    ≤ 2.4V

    ON: LED rosso illuminato

    100Vca

    5 ÷ 20mA

    24Vcc

    5 ÷ 40mA 50mA

    ≤ 24VVca Vcc

    40mA

    Nessuno

    Nessuno

    Nessuno

    48V Vca Vcc

    20mA

    100V Vca Vcc

    0

    D-R731: Montaggio da destra D-R732: Montaggio da sinistra

    D-R801: Montaggio da destra D-R802: Montaggio da sinistra

    D-R731/R732

    D-R801/R802

    CD-P11 CD-P12

    Box diprotezione contatti

    CD-P11 CD-P12

    Box diprotezione contatti

    OUT (±) Marrone (Rosso)

    OUT (±) Blu (Nero )

    OUT(+) Marrone (Rosso)

    Marrone (Rosso)

    Zener diode

    Resistenza

    Diode

    OUT (–) Blu (Nero)

    Blu (Nero )

    Sen

    sori

    reed

    S

    enso

    ri re

    ed

    D ���1 D ���2

    Montaggio da sinistra

    Circuiti interni dei sensori ( ): Anteriori all'adattamento agli standard IEC

    Montaggio da destra

    Dimensioni

    Grommet Cavi: In linea

    Attuatori rotanti applicabili

    Caratteristiche dei sensori

    Serie

    Codice dei sensori

    Applicazioni

    Tensione di carico

    Max. corrente di carico ecampo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    LED Cavi Cavi antiolio per carico pesante 0.2mm2, X2 fili (marrone, blu ) 0.5m Nota 1) Altri dati a p. 6-18.Nota 2) Vedere a p. 6-18 per lunghezza di cavi.

    ~

    ~

    Sensori reed/Montaggio diretto

    D-R73/D-R80

  • 6-38

    Diametro

    20, 30, 50, 80, 100

    20, 30

    7, 20

    Regolazione sensore

    Vedere a p.1.0-19

    Vedere a p.1.0-19

    Vedere a p.1.8-29

    CDRB1

    CDRBU

    MDSUB

    D-R731C/D-R732C D-R801C/D-R802C Relè, PLC Relè, PLC

    PLC: Regolatore logico programmabile

    D-R73 �C ( con LED) D-R80 �C ( senza LED)

    ≤ 2.4V

    24Vcc

    5 ÷ 40mA

    Nessuno Nessuno

    Nessuno

    50mA

    ≤ 24VVca Vcc

    0

    ON: La luce rossa emette diode

    D-R731C: Montaggio da destra D-R732C: Montaggio da sinistra

    D-R801C: Montaggio da destra D-R802C: Montaggio da sinistra

    D-R731/R732

    D-R801/R802

    D ����C

    Montaggio da sinistra Montaggio da destra

    D ����C

    CD-P11 CD-P12

    Box diprotezione contatti

    OUT(+) Marrone(Rosso )

    Marrone (Rosso) Diode

    Sen

    sori

    reed

    S

    enso

    ri re

    ed

    Zener diode

    Resistenza

    OUT (–) Blu (Nero )

    OUT (±) Marrone (Rosso)

    OUT (±) Blu (Nero )

    Blu (Nero )

    ConnettoreConnessione elettrica: In linea

    Attuatori rotanti applicabili

    Caratteristiche dei sensori

    Serie

    Codice dei sensori

    Applicazioni

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    LED Cavi Cavi antiolio per carico pesante ø3.4, 0.2mm2 Nota 1) Altri dati a p. 6-18. Nota 2) Vedere a p. 6-18 per lunghezza di cavi.

    Dimensioni

    Circuiti interni dei sensori ( ): Anteriori all'adattamento agli standard IEC

    Box diprotezione contatti

    CD-P11 CD-P12

    Avvertenze Specifiche del Prodotto Precauzione

    Assicurarsi che non si sia allentato dopo il cablaggiociò limiterebbe la resistenza all'acqua.

    ~

    ~

    Sensori reed/Montaggio diretto

    D-R73�C/D-R80�C

  • 6-39

    Sensori reed/Montaggio diretto

    D-E73A/D-E76A/D-E80A

    D-E73A

    D-E76A

    D-E80A

    Blu(Nero)

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo zener

    Marrone(Rosso) Boxprotezionecontatti

    CD–P11

    CD–P12

    OUT(+) Marrone(Rosso)

    a

    OUT(–) Blu(Nero)

    Sen

    sori

    reed

    Boxprotezionecontatti

    CD–P11 CD–P12

    OUT(±) Marrone(Rosso)

    a OUT( ) Blu(Nero)

    ±

    LED

    Sen

    sori

    reed

    Resistenza

    Diodo antiinversione di flusso

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Carico

    (+)

    (–)

    Ten

    sion

    e (V

    cc)

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø10

    ø25, ø32, ø40

    D–E7 � A (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente carico e campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–E73A

    Relè PLC

    ≤ 2.4V

    24Vcc

    5 ÷ 40mA

    100Vca

    5 ÷ 20mA

    Nessuno

    ON: LED rosso acceso

    D–E76A

    Circuito IC

    4 ÷ 8Vcc

    20mA

    ≤ 0.8V

    D–E80A

    Relè, circuito IC, PLC

    40mA

    Nessuno

    ≤ 1� (compresa una lunghezza cavo di 3m)

    D–E80A (Senza indicatore ottico) Modello sensore

    Applicazione

    Tensione di carico

    Max. corrente di carico

    Circuito di protezione contatti

    Resistenza interna

    Serie attuatori 10 6

    25 6

    32 6

    40 6

    (mm)

    CDBX ML1

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Diametro

    50mA 20mA

    CDBX

    ML1

    Vca Vcc ≤ 24V

    Vca Vcc 48V

    Vca Vcc 100V

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.2mm2 , 3 fili (Marrone, Nero, Blu), 2 fili (Marrone, Blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    Grommet

    Circuito interno( ): Se non conforme a standard IEC

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. e In questo caso la tensione di carico è 100 VcaSi raccomanda di usare il box di protezione contatti nei casi menzionati sopra.Particolari a p.6-19.

    Indicatore ottico

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    senza indicatore ottico

    passante

  • 6-40

    Sensore reed con LED bicolore/Montaggio a fascetta

    D-B59W

    D-B59W

    Indicatore ottico/Operazione

    Il punto d’operazione più idoneo è indicato da una luce verde(Rosso � Verde � Rosso)

    Bobina d'arresto

    Diodo zener

    CircuitoprincipaleIC

    Sensori reed

    LED

    OUT(+) Marrone(Rosso)

    OUT(–) Blu(Nero)

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø20, ø25, ø32, ø40

    ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

    ø20, ø25, ø32, ø40

    ø40, ø50, ø63, ø80, ø100

    ø20, ø25, ø32, ø40, ø50

    ø20, ø25, ø32, ø40

    CDM2, CDBM2, CDVM3, CDVM5, CDLM2

    CDG1, MGG

    CDLG1

    CDA1, CDBA1, CDV3, CDVS, CDLA, CDL1, CE2, CNA

    MGC

    MLGC, RHC, REC

    D–B59W (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–B59W

    Relè PLC

    24Vcc

    5 ÷ 40mA

    Incorporati

    ≤ 4V

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.3mm2 , 2 fili (marrone, blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    Serie attuatori Diametro

    20

    12

    13 13

    13 13

    25

    12

    13 13

    13 13

    32

    13

    14 14

    14 14

    40

    13

    14 14

    14

    14 14

    50

    14

    14

    14

    63

    17

    17

    80

    16

    16

    100

    18

    18

    CDM2, CDBM2, CDVM3, CDVM5, CDLM2

    CDA1, CDBA1, CDV3, CDVS, CDLA, CDL1, CNA, CE2

    (mm)

    CDG1 CDLG1 MGG, MGC MLGC, RHC, REC

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Punto d'operazione: LED rosso acceso

    Operazione ideale: LED verde acceso

    Grommet

    Circuito interno( ): Se non conforme a standard IEC

    Campod'operazione

    Rosso Verde Rosso

    ON

    OFF

    Punto d'operazioneideale

    Indicatore

    Indicatore ottico

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

  • 6-41

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Sensore reed con LED bicolore/Montaggio su guida

    D-A79W

    D-A79W

    Indicatore ottico/Operazione

    Campod'operazione

    Rosso Verde Rosso

    ON

    OFF

    Punto d'operazioneideale

    Indicatore

    Cambio diodo flusso

    LED

    Sensore centrale IC

    Sensori reed

    OUT(+) Marrone(Rosso)

    OUT(–) Blu(Nero)

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø10, ø16

    ø16

    ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100, ø125, ø140, ø160

    ø20, ø25, ø32, ø40, ø50

    ø25, ø32, ø40, ø50, ø63

    ø12, ø20, ø32, ø40, ø50, ø63

    ø20, ø25, ø32, ø40, ø50, ø63

    ø32, ø40

    CDJ2, CDVJ

    CDLJ2

    CDQ2

    RSDQ

    MDU

    CE1

    MK, MK2

    CXT

    D–A79W (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–A79W

    Relè PLC

    24Vcc

    5 ÷ 40mA

    Nessuno

    ≤ 4V

    Serie attuatori Diametro

    6 10 11

    12

    13

    13

    15 16 13 13 13

    20

    13 13

    13 13

    25

    13 13 13

    13

    32

    13 13 13 13 13 13

    40

    14 14 14 14 14 14

    50

    14 14 14 14 14

    63

    16

    14 16 16

    80

    15

    100

    17

    125

    17

    140

    17

    160

    17

    (mm)

    CDJ2, CDVJ CDLJ2 CDQ2 RSDQ MDU CE1 MK, MK2 CXT

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Punto d'operazione: LED rosso acceso

    Operazione ideale: LED verde acceso

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.2mm2 , 2 fili (marrone, blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    Il punto d’operazione più idoneo è indicato da una luce verde(Rosso � Verde � Rosso)

    Grommet

    Circuito interno( ): Se non conforme a standard IEC

    Nota) q Se il carico d’esercizio è un carico induttivo w Se la lunghezza del cavo del carico è >5m. Si raccomanda di usare il box di protezione contatti nei casi menzionati sopra. Particolari sui box protezione contatti a p.6-19.

  • 6-42

    Sensori reed con LED bicolore/Montaggio con tiranti

    D-A59W

    D-A59W

    Indicatore

    Campo d'operazione

    Rosso Verde Rosso

    ON

    OFF

    Operazione ideale

    Bobina d'arresto

    Diodo zener

    CircuitoprincipaleIC

    Sensori reed

    LED

    OUT(+) Marrone(Rosso)

    OUT(–) Blu(Nero)

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø40, ø50, ø63, ø80, ø100

    ø40, ø50, ø63, ø80, ø100, ø125, ø140, ø160

    ø125, ø140, ø160, ø180, ø200

    ø32, ø40, ø50, ø63, ø80, ø100

    CDA1, CDBA1, CDV3, CDVS, CDLA, CE2, CNA

    CDL1

    CDS1 MDB, MDBB

    D–A59W (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Applicazione

    Tensione di carico

    Campo corrente di carico

    Circuito di protezione contatti

    Cadute interne di tensione

    Indicatore ottico

    D–A59W

    Relè PLC

    24Vcc

    5 ÷ 40mA

    Incorporati

    ≤ 4V

    Serie attuatori Diametro

    200

    17

    180

    17

    160

    17 17

    140

    17 17

    125

    17 17

    100

    15

    15

    15

    80

    14

    14

    14

    63

    14

    14

    14

    50

    13

    13

    13

    40

    13

    13

    13

    32

    13

    CDA1, CDBA1, CDV3, CDVS, CDLA, CE2, CNA

    (mm)

    CDL1 CDS1 MDB, MDBB

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Punto d'operazione: LED rosso acceso

    Operazione ideale: LED verde accesoLunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.3mm 2 , 2 fili (marrone, blu), 0.5m

    Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    Il punto d’operazione più idoneo è indicato da una luce verde(Rosso � Verde � Rosso)

    Grommet

    Circuito interno( ): Se non conforme a standard IEC

    Indicatore ottico/Operazione

    Indicatore ottico

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

  • 6-43

    Sensori allo stato solidoSensori generici, LED bicolore, LED bicolore con uscita di diagnostica, Resistente all’acqua con LED bic., Con Timer, Resistente ai campi magnetici intensi

  • 6-44

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø6, ø10, ø16

    ø10, ø16

    ø16

    ø20, ø25, ø32, ø40

    ø20, ø25, ø32, ø40, ø50, ø63

    ø40, ø50

    ø20, ø25, ø32, ø40, ø50

    ø20, ø25, ø32, ø40

    CDJ2

    CDVJ3, CDVJ5

    CDLJ2

    CDM2, CDBM2, CDVM3,CDVM5, CDLM2, CDLG1, REC

    CDG1, MGG

    RSDG

    MGC

    RHC, MLGC

    D–H7 (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Commutazione

    Uscita

    Applicazione

    Tensione

    Consumo di corrente

    Tensione di carico

    Corrente di carico

    Cadute interne di tensione

    Dispersione di corrente

    Indicatore ottico

    D–H7A1

    NPN

    ≤ 28Vcc

    ≤ 40mA ≤ 1.5V

    D–H7A2

    PNP

    ≤ 80mA

    ≤ 0.8V

    ON: LED rosso acceso

    D–H7B

    2 fili

    24Vcc Relè/PLC

    24Vcc (10 ÷ 28Vcc)

    5 ÷ 40mA

    ≤ 4V

    0.8mA con 24Vcc

    Serie attuatori Diametro

    6 3

    10 4 4

    15 16 4 4 4

    20 4

    4 4 4

    25 4

    4 4 4

    32 4.5

    4.5

    4.5 4.5

    40 5

    5 5 5 5

    50

    6 6 6

    63

    6.5

    CDJ2 CDVJ3, CDVJ5 CDLJ2 CDM2, CDBM2, CDVM3, CDVM5, CDLM2, CDLG1, REC CDG1, MGG RSDG MGG, MGC RHC, MLGC

    (mm)

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    3 fili

    Circuito IC/Relè/PLC

    5/12/24Vcc (4.5 ÷ 28Vcc)

    ≤ 10mA

    ≤100�A con 24Vcc

    ≤ 0.8V con 10mA della corrente di carico

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.2mm2 , 3 fili (Marrone, Nero, Blu), 2 fili (Marrone, Blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    Sensori allo stato solido/Montaggio a fascetta

    D-H7A1/D-H7A2/D-H7B

    D-H7A1

    D-H7A2

    D-H7B

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Circu

    ito pr

    incipa

    le IC

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Circu

    ito pr

    incipa

    le IC

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Circu

    ito pr

    incipa

    le IC

    Grommet

    Circuito interno( ): Se non conforme a standard IEC

    Indicatore ottico

    Campo d'operazione (Vedere tabella sotto.)

    Posizione più sensibile

    Foro di montaggio

  • 6-45

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

    ø40, ø50, ø63, ø80, ø100

    ø20, ø25, ø32, ø40, ø50

    ø20, ø25, ø32, ø40

    ø40, ø50, ø63, ø80, ø100

    CDG1, MGG

    CDA1, CDBA1, CDV3, CDVS, CDLA, CDL1, CNA

    MGC

    RHC, MLGC, REC

    CE2

    D–G5 � D–K59 (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Commutazione

    Uscita

    Applicazione

    Tensione

    Consumo di corrente

    Tensione di carico

    Corrente di carico

    Cadute interne di tensione

    Dispersione di corrente

    Indicatore ottico

    D–G59

    NPN

    ≤ 28Vcc

    ≤ 40mA

    ≤ 1.5V

    D–G5P

    PNP

    ≤ 80mA

    ≤ 0.8V

    ON: LED rosso acceso

    D–K59

    2 fili

    24Vcc Relè/PLC

    24Vcc (10 ÷ 28Vcc)

    5 ÷ 40mA

    ≤ 4V

    ≤ 0.8mA con 24Vcc

    Serie attuatori Diametro

    20 4 4 4

    25 4 4 4

    32 4.5

    4.5 4.5

    40 5 5 5 5 5

    50 6 6 6 6

    63 6.5

    6.5

    6.5

    80 6.5

    6.5

    6.5

    100 7

    7

    7

    CDG1, MGG CDA1, CDBA1, CDV3, CDVS, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE2

    (mm)

    Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    3 fili

    Relè, circuito IC, PLC

    5/12/24Vcc (4.5 ÷ 28Vcc)

    ≤10mA

    ≤ 100�A con 24Vcc

    ≤ 0.8V con 10mA della corrente di carico

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.3mm 2 , 3 fili (Marrone, Nero, Blu), 2 fili (Marrone, Blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    Sensori allo stato solido/Montaggio a fascetta

    D-G59/D-G5P/D-K59

    D-G59

    D-G5P

    D-K59

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Circu

    ito pr

    incipa

    le IC

    OUT Nero(Bianco)

    Vcc(+) Marrone(Rosso)

    Vcc(–) Blu(Nero)

    Circu

    itp pr

    incipa

    le IC

    OUT(+) Marrone(Rosso)

    OUT(–) Blu(Nero)

    Circu

    ito pr

    incipa

    le IC

    Grommet

    Circuito interno( ): Se non conforme a standard IEC

    Indicatore ottico

    Campo d'operazione (Vedere tabella sotto.) Posizione più sensibile

    Foro di montaggio

  • 6-46

    Serie attuatori applicabili

    Dati tecnici

    Dimensioni

    Campo di funzionamento ( l Dimensione)

    Serie Diametro (mm)

    ø6, ø10, ø16

    ø10, ø16

    ø16

    ø20, ø25, ø32, ø40

    ø20, ø25, ø32, ø40, ø50, ø63

    ø40, ø50

    ø20, ø25, ø32, ø40, ø50

    ø20, ø25, ø32, ø40

    CDJ2

    CDVJ3, CDVJ5

    CDLJ2

    CDM2, CDBM2, CDVM3, CDVM5, CDLM2, CDLG1, REC

    CDG1, MGG

    RSDG

    MGC

    RHC, MLGC

    D–H7C (Con indicatore ottico) PLC: Regolatore logico programmabile

    Modello sensore

    Commutazione

    Uscita

    Applicazione

    Tensione

    Consumo di corrente

    Tensione di carico

    Corrente di carico

    Cadute interne di tensione

    Dispersione di corrente

    Indicatore ottico

    D–H7C

    2 fili

    24Vcc Relè/PLC

    24Vcc (10 ÷ 28Vcc)

    5 ÷ 40mA

    ≤ 4V

    ≤ 0.8mA a 24Vcc

    ON: LED rosso acceso

    Serie attuatori Diametro

    6 5

    10 8 8

    15 16 9 9 9

    20 7

    7 7 7

    25

    8.5

    8.5

    8.5 8.5

    32 9

    9 9 9

    40

    10

    10 10 10 10

    50

    9.5 9.5 9.5

    63

    10.5

    (mm)

    CJ2CDVJ3, CDVJ5 CDLJ2 CDM2, CDBM2, CDVM3, CDVM5, CDM2, CDLG1, REC CDG1, MGG RSDQ MGC RHC, MLGC Nota) I valori medi delle temperature normali includono isteresi. (±30% di tolleranza)

    Lunghezza cavi –– Cavo vinilico antiolio, ø3.4, 0.2mm 2 , 2 fili (marrone, blu), 0.5m Nota 1) Vedere i dati tecnici comuni a p. 6-18. Nota 2) Vedere lunghezza cavi a p. 6-18.

    Sensori allo stato solido/Montaggio a fascetta

    D-H7C